Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 carel 1.3.6.1.4.1.9839
           systm 1.3.6.1.4.1.9839.1
               agentRelease 1.3.6.1.4.1.9839.1.1 integer32 read-only
Release of the Agent.
               agentCode 1.3.6.1.4.1.9839.1.2 integer32 read-only
Code of the Agent. 2=pCOWeb.
           instruments 1.3.6.1.4.1.9839.2
               pCOWebInfo 1.3.6.1.4.1.9839.2.0
                   pCOStatusgroup 1.3.6.1.4.1.9839.2.0.10
                         pCOId1_Status 1.3.6.1.4.1.9839.2.0.10.1 integer32 read-only
Status of pCOId1. 0=Offline, 1=Init, 2=Online
                   pCOErrorsNumbergroup 1.3.6.1.4.1.9839.2.0.11
                         pCOId1_ErrorsNumber 1.3.6.1.4.1.9839.2.0.11.1 integer32 read-only
Number of Communication Errors from pCOId1 to pCOWeb.
               uncdz_MIB 1.3.6.1.4.1.9839.2.1
This is the MIB module for the UNIFLAIR UNCDZ device.
                   digitalObjects 1.3.6.1.4.1.9839.2.1.1
                       vent_on 1.3.6.1.4.1.9839.2.1.1.1 integer32 read-only
System On (Fan)
                       compressore1 1.3.6.1.4.1.9839.2.1.1.2 integer32 read-only
Compressor 1
                       compressore2 1.3.6.1.4.1.9839.2.1.1.3 integer32 read-only
Compressor 2
                       compressore3 1.3.6.1.4.1.9839.2.1.1.4 integer32 read-only
Compressor 3
                       compressore4 1.3.6.1.4.1.9839.2.1.1.5 integer32 read-only
Compressor 4
                       out_h1 1.3.6.1.4.1.9839.2.1.1.6 integer32 read-only
Heating 1
                       out_h2 1.3.6.1.4.1.9839.2.1.1.7 integer32 read-only
Heating 2
                       out_h3 1.3.6.1.4.1.9839.2.1.1.8 integer32 read-only
Heating 3
                       gas_caldo_on 1.3.6.1.4.1.9839.2.1.1.9 integer32 read-only
Hot Gas Coil
                       on_deum 1.3.6.1.4.1.9839.2.1.1.10 integer32 read-only
Dehumidification
                       power 1.3.6.1.4.1.9839.2.1.1.11 integer32 read-only
Humidification
                       mal_access 1.3.6.1.4.1.9839.2.1.1.12 integer32 read-only
Tampering Alarm
                       mal_ata 1.3.6.1.4.1.9839.2.1.1.13 integer32 read-only
Alarm: Room High Temperature
                       mal_bta 1.3.6.1.4.1.9839.2.1.1.14 integer32 read-only
Alarm: Room Low Temperature
                       mal_aua 1.3.6.1.4.1.9839.2.1.1.15 integer32 read-only
Alarm: Room High Humidity
                       mal_bua 1.3.6.1.4.1.9839.2.1.1.16 integer32 read-only
Alarm: Room Low Humidity
                       mal_eap 1.3.6.1.4.1.9839.2.1.1.17 integer32 read-only
Alarm: Room High/Low Temp./Humid.(Ext. Devices)
                       mal_filter 1.3.6.1.4.1.9839.2.1.1.18 integer32 read-only
Alarm: Clogged Filter
                       mal_flood 1.3.6.1.4.1.9839.2.1.1.19 integer32 read-only
Alarm: Water Leakage Detected
                       mal_flux 1.3.6.1.4.1.9839.2.1.1.20 integer32 read-only
Alarm: Loss of Air Flow
                       mal_heater 1.3.6.1.4.1.9839.2.1.1.21 integer32 read-only
Alarm: Heater Overheating
                       mal_hp1 1.3.6.1.4.1.9839.2.1.1.22 integer32 read-only
Alarm: High Pressure 1
                       mal_hp2 1.3.6.1.4.1.9839.2.1.1.23 integer32 read-only
Alarm: High Pressure 2
                       mal_lp1 1.3.6.1.4.1.9839.2.1.1.24 integer32 read-only
Alarm: Low Pressure 1
                       mal_lp2 1.3.6.1.4.1.9839.2.1.1.25 integer32 read-only
Alarm: Low Pressure 2
                       mal_phase 1.3.6.1.4.1.9839.2.1.1.26 integer32 read-only
Alarm: Wrong phase sequence
                       mal_smoke 1.3.6.1.4.1.9839.2.1.1.27 integer32 read-only
Alarm: SMOKE-FIRE DETECTED
                       mal_lan 1.3.6.1.4.1.9839.2.1.1.28 integer32 read-only
Alarm: Interrupted LAN
                       mal_hcurr 1.3.6.1.4.1.9839.2.1.1.29 integer32 read-only
Humidifier Alarm: High Current
                       mal_nopower 1.3.6.1.4.1.9839.2.1.1.30 integer32 read-only
Humidifier Alarm: Power Loss
                       mal_nowater 1.3.6.1.4.1.9839.2.1.1.31 integer32 read-only
Humidifier Alarm: Water Loss
                       mal_cw_dh 1.3.6.1.4.1.9839.2.1.1.32 integer32 read-only
Alarm: Chilled Water Temp. too High for Dehumidification
                       mal_tc_cw 1.3.6.1.4.1.9839.2.1.1.33 integer32 read-only
Alarm: CW Valve Failure or Water Flow too Low
                       mal_wflow 1.3.6.1.4.1.9839.2.1.1.34 integer32 read-only
Alarm: Loss of Water flow
                       mal_wht 1.3.6.1.4.1.9839.2.1.1.35 integer32 read-only
Alarm: High chilled water temp.
                       mal_sonda_ta 1.3.6.1.4.1.9839.2.1.1.36 integer32 read-only
Alarm: Room air Sensor Failure/Disconnected
                       mal_sonda_tac 1.3.6.1.4.1.9839.2.1.1.37 integer32 read-only
Alarm: Hot water Sensor Failure/Disconnected
                       mal_sonda_tc 1.3.6.1.4.1.9839.2.1.1.38 integer32 read-only
Alarm: Condensing water Sensor Failure/Disconnect.
                       mal_sonda_te 1.3.6.1.4.1.9839.2.1.1.39 integer32 read-only
Alarm: Outdoor temp. Sensor Failure/Disconnected
                       mal_sonda_tm 1.3.6.1.4.1.9839.2.1.1.40 integer32 read-only
Alarm: Delivery temp. Sensor Failure/Disconnected
                       mal_sonda_ua 1.3.6.1.4.1.9839.2.1.1.41 integer32 read-only
Alarm: Rel. Humidity Sensor Failure/Disconnected
                       mal_ore_compr1 1.3.6.1.4.1.9839.2.1.1.42 integer32 read-only
Service Alarm: Compressor 1 hour counter threshold
                       mal_ore_compr2 1.3.6.1.4.1.9839.2.1.1.43 integer32 read-only
Service Alarm: Compressor 2 hour counter threshold
                       mal_ore_compr3 1.3.6.1.4.1.9839.2.1.1.44 integer32 read-only
Service Alarm: Compressor 3 hour counter threshold
                       mal_ore_compr4 1.3.6.1.4.1.9839.2.1.1.45 integer32 read-only
Service Alarm: Compressor 4 hour counter threshold
                       mal_ore_filtro 1.3.6.1.4.1.9839.2.1.1.46 integer32 read-only
Service Alarm: Air Filter hour counter threshold
                       mal_ore_risc1 1.3.6.1.4.1.9839.2.1.1.47 integer32 read-only
Service Alarm: Heater 1 hour counter threshold
                       mal_ore_risc2 1.3.6.1.4.1.9839.2.1.1.48 integer32 read-only
Service Alarm: Heater 2 hour counter threshold
                       mal_ore_umid 1.3.6.1.4.1.9839.2.1.1.49 integer32 read-only
Service Alarm: Humidifier hour counter threshold
                       mal_ore_unit 1.3.6.1.4.1.9839.2.1.1.50 integer32 read-only
Service Alarm: Unit hour counter threshold
                       glb_al 1.3.6.1.4.1.9839.2.1.1.51 integer32 read-only
General Alarm
                       or_al_2lev 1.3.6.1.4.1.9839.2.1.1.52 integer32 read-only
2nd Level Alarm
                       range_t_ext 1.3.6.1.4.1.9839.2.1.1.53 integer32 read-only
Outdoor Temp. Sensor Fitted
                       range_t_circ 1.3.6.1.4.1.9839.2.1.1.54 integer32 read-only
Closed Circuit (or Chilled) Water Temperature Sensor Fitted
                       range_t_man 1.3.6.1.4.1.9839.2.1.1.55 integer32 read-only
Delivery Temp. Sensor Fitted
                       range_t_ac 1.3.6.1.4.1.9839.2.1.1.56 integer32 read-only
Hot water temp. Sensor Fitted
                       umid_al 1.3.6.1.4.1.9839.2.1.1.57 integer32 read-only
Humidifier general alarm
                       range_u_amb 1.3.6.1.4.1.9839.2.1.1.58 integer32 read-only
Relative Humidity Sensor Fitted
                       k_syson 1.3.6.1.4.1.9839.2.1.1.60 integer32 read-write
Unit Remote Switch-On/Off Control
                       xs_res_al 1.3.6.1.4.1.9839.2.1.1.61 integer32 read-write
Buzzer and Alarm Remote Reset Control
                       sleep_mode 1.3.6.1.4.1.9839.2.1.1.63 integer32 read-write
Set Back Mode (Sleep Mode)
                       test_sm 1.3.6.1.4.1.9839.2.1.1.64 integer32 read-write
Set Back mode: Cyclical Start of Fan
                       ab_mediath 1.3.6.1.4.1.9839.2.1.1.65 integer32 read-write
Usage of T+ H Values: Local (0) / Mean (1)
                       ustdby1_2 1.3.6.1.4.1.9839.2.1.1.66 integer32 read-write
No. Of Stand-by Units: one (0) / two (1)
                       emerg 1.3.6.1.4.1.9839.2.1.1.67 integer32 read-only
Unit in Emergency operation
                   analogObjects 1.3.6.1.4.1.9839.2.1.2
                       temp_amb 1.3.6.1.4.1.9839.2.1.2.1 integer32 read-only
Room Temperature
                       temp_ext 1.3.6.1.4.1.9839.2.1.2.2 integer32 read-only
Outdoor Temperature
                       temp_mand 1.3.6.1.4.1.9839.2.1.2.3 integer32 read-only
Delivery Air Temperature
                       temp_circ 1.3.6.1.4.1.9839.2.1.2.4 integer32 read-only
Closed Circuit (or Chilled) Water Temperature
                       temp_ac 1.3.6.1.4.1.9839.2.1.2.5 integer32 read-only
Hot Water Temperature
                       umid_amb 1.3.6.1.4.1.9839.2.1.2.6 integer32 read-only
Room Relative Humidity
                       t_set 1.3.6.1.4.1.9839.2.1.2.7 integer32 read-write
Cooling Set Point
                       t_diff 1.3.6.1.4.1.9839.2.1.2.8 integer32 read-write
Cooling Prop.Band
                       t_set_c 1.3.6.1.4.1.9839.2.1.2.9 integer32 read-write
Heating Set point
                       t_diff_c 1.3.6.1.4.1.9839.2.1.2.10 integer32 read-write
Heating Prop.Band
                       ht_set 1.3.6.1.4.1.9839.2.1.2.11 integer32 read-write
Room High Temp. Alarm Threshold
                       lt_set 1.3.6.1.4.1.9839.2.1.2.12 integer32 read-write
Room Low Temp. Alarm Threshold
                       t_set_sm 1.3.6.1.4.1.9839.2.1.2.13 integer32 read-write
Setback Mode: Cooling Set Point
                       t_set_c_sm 1.3.6.1.4.1.9839.2.1.2.14 integer32 read-write
Setback Mode: Heating Set Point
                       t_cw_dh 1.3.6.1.4.1.9839.2.1.2.15 integer32 read-write
CW Set Point to Start Dehumidification Cycle
                       htset_cw 1.3.6.1.4.1.9839.2.1.2.16 integer32 read-write
CW High Temperature Alarm Threshold
                       t_set_cw 1.3.6.1.4.1.9839.2.1.2.17 integer32 read-write
CW Set Point to Start CW Operating Mode (TC only)
                       t_rc_es 1.3.6.1.4.1.9839.2.1.2.18 integer32 read-write
Rad-cooler Set Point in E.S. Mode (ES Only)
                       t_rc_est 1.3.6.1.4.1.9839.2.1.2.19 integer32 read-write
Rad-cooler Set Point in DX Mode (ES Only)
                       rampa_valv 1.3.6.1.4.1.9839.2.1.2.20 integer32 read-only
0-10V Ramp 1 Value (CW Valve Ramp)
                       anaout2 1.3.6.1.4.1.9839.2.1.2.21 integer32 read-only
0-10V Ramp 2 Value (HW Valve/Rad Cooler Ramp)
                       steam_production 1.3.6.1.4.1.9839.2.1.2.22 integer32 read-only
Humidifier: steam capacity
                       t_set_lm 1.3.6.1.4.1.9839.2.1.2.23 integer32 read-write
Delivery Air Temperature Limit Set Point
                       delta_lm 1.3.6.1.4.1.9839.2.1.2.24 integer32 read-write
T+H Values: Mean/Local Diff. (aut. Changeover)
                   integerObjects 1.3.6.1.4.1.9839.2.1.3
                       ore_filtro 1.3.6.1.4.1.9839.2.1.3.1 integer32 read-only
Air Filter Working Houres
                       ore_unit 1.3.6.1.4.1.9839.2.1.3.2 integer32 read-only
Unit Working Houres
                       ore_compr1 1.3.6.1.4.1.9839.2.1.3.3 integer32 read-only
Compressor 1 Working Houres
                       ore_compr2 1.3.6.1.4.1.9839.2.1.3.4 integer32 read-only
Compressor 2 Working Houres
                       ore_compr3 1.3.6.1.4.1.9839.2.1.3.5 integer32 read-only
Compressor 3 Working Houres
                       ore_compr4 1.3.6.1.4.1.9839.2.1.3.6 integer32 read-only
Compressor 4 Working Houres
                       ore_heat1 1.3.6.1.4.1.9839.2.1.3.7 integer32 read-only
Heater 1 Working Houres
                       ore_heat2 1.3.6.1.4.1.9839.2.1.3.8 integer32 read-only
Heater 2 Working Houres
                       ore_umid 1.3.6.1.4.1.9839.2.1.3.9 integer32 read-only
Humidifier Working Houres
                       hdiff 1.3.6.1.4.1.9839.2.1.3.12 integer32 read-write
Dehumidification Proportional Band
                       hu_diff 1.3.6.1.4.1.9839.2.1.3.13 integer32 read-write
Humidification Proportional Band
                       hh_set 1.3.6.1.4.1.9839.2.1.3.14 integer32 read-write
High Relative Humidity Alarm Threshold
                       lh_set 1.3.6.1.4.1.9839.2.1.3.15 integer32 read-write
Low Relative Humidity Alarm Threshold
                       hset 1.3.6.1.4.1.9839.2.1.3.16 integer32 read-write
Dehumidification Set Point
                       hset_sm 1.3.6.1.4.1.9839.2.1.3.17 integer32 read-write
Setback Mode: Dehumidification Set Point
                       hu_set 1.3.6.1.4.1.9839.2.1.3.18 integer32 read-write
Humidification Set Point
                       hu_set_sm 1.3.6.1.4.1.9839.2.1.3.19 integer32 read-write
Setback Mode: Humidification Set Point
                       restart_delay 1.3.6.1.4.1.9839.2.1.3.20 integer32 read-write
Restart Delay
                       regul_delay 1.3.6.1.4.1.9839.2.1.3.21 integer32 read-write
Regulation Start Transitory
                       time_lowp 1.3.6.1.4.1.9839.2.1.3.22 integer32 read-write
Low Pressure Delay
                       alarm_delay 1.3.6.1.4.1.9839.2.1.3.23 integer32 read-write
Room T+H Alarm Delay
                       exc_time 1.3.6.1.4.1.9839.2.1.3.24 integer32 read-write
Anti-Hunting Constant of Room Regulation
                       t_std_by 1.3.6.1.4.1.9839.2.1.3.25 integer32 read-write
Stand-by Cycle Base Time
                       lan_unit 1.3.6.1.4.1.9839.2.1.3.27 integer32 read-write
Total of units connected in LAN
                       ciclo_sm 1.3.6.1.4.1.9839.2.1.3.28 integer32 read-write
Set Back Mode: Fan Cyclical Start Interval