SLE-MPLS-TP-TUNNEL-MIB: View SNMP OID List / Download MIB
VENDOR: DASAN CO.,LTD.
Home | MIB: SLE-MPLS-TP-TUNNEL-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
sleMpls | 1.3.6.1.4.1.6296.101.16 |
SLE MPLS. |
||
sleMplsTpTunnel | 1.3.6.1.4.1.6296.101.16.14 |
Copyright (C) The Internet Society (2004). The initial version of this MIB module was published in RFC 3812. For full legal notices see the RFC itself or see: http://www.ietf.org/copyrights/ianamib.html This MIB module contains managed object definitions for MPLS Traffic Engineering (TE) as defined in: 1. Extensions to RSVP for LSP Tunnels, Awduche et al, RFC 3209, December 2001 2. Constraint-Based LSP Setup using LDP, Jamoussi (Editor), RFC 3212, January 2002 3. Requirements for Traffic Engineering Over MPLS, Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M., and J. McManus, [RFC2702], September 1999 |
||
sleMplsTpTunnelCfg | 1.3.6.1.4.1.6296.101.16.14.1 | |||
sleMplsTpTunnelCfgInfoTable | 1.3.6.1.4.1.6296.101.16.14.1.1 | no-access |
The mplsTunnelTable allows new MPLS tunnels to be created between an LSR and a remote endpoint, and existing tunnels to be reconfigured or removed. Note that only point-to-point tunnel segments are supported, although multipoint-to-point and point- to-multipoint connections are supported by an LSR acting as a cross-connect. Each MPLS tunnel can thus have one out-segment originating at this LSR and/or one in-segment terminating at this LSR. |
|
1.3.6.1.4.1.6296.101.16.14.1.1.1 | no-access |
An entry in this table represents an MPLS tunnel. An entry can be created by a network administrator or by an SNMP agent as instructed by an MPLS signalling protocol. Whenever a new entry is created with mplsTunnelIsIf set to true(1), then a corresponding entry is created in ifTable as well (see RFC 2863). The ifType of this entry is mplsTunnel(150). A tunnel entry needs to be uniquely identified across a MPLS network. Indices mplsTunnelIndex and mplsTunnelInstance uniquely identify a tunnel on the LSR originating the tunnel. To uniquely identify a tunnel across an MPLS network requires index mplsTunnelIngressLSRId. The last index mplsTunnelEgressLSRId is useful in identifying all instances of a tunnel that terminate on the same egress LSR. |
||
sleMplsTpTunnelCfgInfoIndex | 1.3.6.1.4.1.6296.101.16.14.1.1.1.1 | unsigned32 | no-access |
A unique value which identify an entry in this table. |
sleMplsTpTunnelCfgInfoName | 1.3.6.1.4.1.6296.101.16.14.1.1.1.2 | octet string | read-only |
The canonical name assigned to the tunnel. This name can be used to refer to the tunnel on the LSR's console port. If mplsTunnelIsIf is set to true then the ifName of the interface corresponding to this tunnel should have a value equal to mplsTunnelName. Also see the description of ifName in RFC 2863. |
sleMplsTpTunnelCfgInfoId | 1.3.6.1.4.1.6296.101.16.14.1.1.1.3 | unsigned32 | read-only |
Uniquely identifies a set of tunnel instances between a pair of ingress and egress LSRs. Managers should obtain new values for row creation in this table by reading mplsTunnelIndexNext. When the MPLS signalling protocol is rsvp(2) this value SHOULD be equal to the value signaled in the Tunnel Id of the Session object. When the MPLS signalling protocol is crldp(3) this value SHOULD be equal to the value signaled in the LSP ID. |
sleMplsTpTunnelCfgInfoSrcIdType | 1.3.6.1.4.1.6296.101.16.14.1.1.1.4 | integer | read-only |
This object is used to set the ietf or itut type. Enumeration: 'ietf': 1, 'itut': 2. |
sleMplsTpTunnelCfgInfoSrcGId | 1.3.6.1.4.1.6296.101.16.14.1.1.1.5 | unsigned32 | read-only |
This Object is used to display the GlobalID of IETF |
sleMplsTpTunnelCfgInfoSrcCc | 1.3.6.1.4.1.6296.101.16.14.1.1.1.6 | mplsccid | read-only |
This Object is used to display the Source CC-ID of ITUT |
sleMplsTpTunnelCfgInfoSrcIcc | 1.3.6.1.4.1.6296.101.16.14.1.1.1.7 | mplsiccid | read-only |
This Object is used to set the Source ICC-ID of ITUT |
sleMplsTpTunnelCfgInfoSrcNodeId | 1.3.6.1.4.1.6296.101.16.14.1.1.1.8 | ipaddress | read-only |
This Object is used to display the Source Node ID of IETF and ITUT |
sleMplsTpTunnelCfgInfoDestIdType | 1.3.6.1.4.1.6296.101.16.14.1.1.1.9 | integer | read-only |
This object is used to set the ietf or itut type. Enumeration: 'ietf': 1, 'itut': 2. |
sleMplsTpTunnelCfgInfoDestGId | 1.3.6.1.4.1.6296.101.16.14.1.1.1.10 | unsigned32 | read-only |
This Object is used to set the Destination GlobalID of IETF |
sleMplsTpTunnelCfgInfoDestCc | 1.3.6.1.4.1.6296.101.16.14.1.1.1.11 | mplsccid | read-only |
This Object is used to display the Destination CC-ID of ITUT |
sleMplsTpTunnelCfgInfoDestIcc | 1.3.6.1.4.1.6296.101.16.14.1.1.1.12 | mplsiccid | read-only |
This Object is used to set the Destination ICC-ID of ITUT |
sleMplsTpTunnelCfgInfoDestNodeId | 1.3.6.1.4.1.6296.101.16.14.1.1.1.13 | ipaddress | read-only |
This Object is used to display the Destination Node ID of IETF and ITUT |
sleMplsTpTunnelCfgInfoMode | 1.3.6.1.4.1.6296.101.16.14.1.1.1.14 | integer | read-only |
This object is used to set the Tunnel Mode Enumeration: 'bidirectional': 2, 'none': 0, 'associate': 4, 'unidirectional': 1, 'corouted': 3. |
sleMplsTpTunnelCfgInfoFwdInLabel | 1.3.6.1.4.1.6296.101.16.14.1.1.1.15 | mplslabel | read-only |
This object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575.. The default value 1048576 is invalid label |
sleMplsTpTunnelCfgInfoFwdInIfIndex | 1.3.6.1.4.1.6296.101.16.14.1.1.1.16 | interfaceindexorzero | read-only |
This object is used to set the Forward IN Interface index |
sleMplsTpTunnelCfgInfoFwdOperation | 1.3.6.1.4.1.6296.101.16.14.1.1.1.17 | integer | read-only |
This object is used to set the Forward Ilm OPeration . Enumeration: 'push': 1, 'none': 0, 'swap': 3, 'pop': 2. |
sleMplsTpTunnelCfgInfoFwdOutLabel | 1.3.6.1.4.1.6296.101.16.14.1.1.1.18 | mplslabel | read-only |
This object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575. The default value 1048576 is invalid label |
sleMplsTpTunnelCfgInfoFwdOutIfIndex | 1.3.6.1.4.1.6296.101.16.14.1.1.1.19 | interfaceindexorzero | read-only |
This object is used to set the Forward OUT Interface index |
sleMplsTpTunnelCfgInfoFwdOutMac | 1.3.6.1.4.1.6296.101.16.14.1.1.1.20 | macaddress | read-only |
This object is used to display the Forward OUT MAC ADDRESS |
sleMplsTpTunnelCfgInfoRevInLabel | 1.3.6.1.4.1.6296.101.16.14.1.1.1.21 | mplslabel | read-only |
This object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575. The default value 1048576 is invalid label |
sleMplsTpTunnelCfgInfoRevInIfIndex | 1.3.6.1.4.1.6296.101.16.14.1.1.1.22 | interfaceindexorzero | read-only |
This object is used to set the Reverse IN Interface index |
sleMplsTpTunnelCfgInfoRevOperation | 1.3.6.1.4.1.6296.101.16.14.1.1.1.23 | integer | read-only |
This object is used to set the Reverse Ilm OPeration . Enumeration: 'push': 1, 'none': 0, 'swap': 3, 'pop': 2. |
sleMplsTpTunnelCfgInfoRevOutLabel | 1.3.6.1.4.1.6296.101.16.14.1.1.1.24 | mplslabel | read-only |
This object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575. The default value 1048576 is invalid label |
sleMplsTpTunnelCfgInfoRevOutIfIndex | 1.3.6.1.4.1.6296.101.16.14.1.1.1.25 | interfaceindexorzero | read-only |
This object is used to set the Reverse OUT Interface index |
sleMplsTpTunnelCfgInfoRevOutMac | 1.3.6.1.4.1.6296.101.16.14.1.1.1.26 | macaddress | read-only |
This object is used to display the Forward OUT MAC ADDRESS . |
sleMplsTpTunnelCfgInfoState | 1.3.6.1.4.1.6296.101.16.14.1.1.1.27 | integer | read-only |
This object is to display status of the tunnel. Enumeration: 'down': 2, 'up': 1. |
sleMplsTpTunnelCfgInfoRole | 1.3.6.1.4.1.6296.101.16.14.1.1.1.28 | integer | read-only |
This object is to display Role of the tunnel. Enumeration: 'source': 0, 'transist': 1, 'destination': 2. |
sleMplsTpTunnelCfgInfoAssociateTnlName | 1.3.6.1.4.1.6296.101.16.14.1.1.1.29 | octet string | read-only |
This object to display associate of reverse tunnel. |
sleMplsTpTunnelCfgInfoDescription | 1.3.6.1.4.1.6296.101.16.14.1.1.1.30 | octet string | read-only |
Description. |
sleMplsTpTunnelCfgInfoHlspRole | 1.3.6.1.4.1.6296.101.16.14.1.1.1.31 | integer | read-only |
This object is used to set the Hlsp Tunnel. whether the tunnel is Server or client. server (1) :- To set the Server Tunnel client(2) :- To set the Client Tunnel . Enumeration: 'client': 2, 'server': 1. |
sleMplsTpTunnelCfgInfoHlspServerTunnelName | 1.3.6.1.4.1.6296.101.16.14.1.1.1.32 | octet string | read-only |
This object is used to set the server TunnelName, when sleMplsTpTunnelCfgControlHlspOption as a client . |
sleMplsTpTunnelCfgInfoQosPolicyName | 1.3.6.1.4.1.6296.101.16.14.1.1.1.33 | octet string | read-only |
This object is used to set the Qos Policy name. |
sleMplsTpTunnelCfgControl | 1.3.6.1.4.1.6296.101.16.14.1.2 | |||
sleMplsTpTunnelCfgControlRequest | 1.3.6.1.4.1.6296.101.16.14.1.2.1 | integer | read-write |
This object holds the possible read-write columns that can be modified in the Tunnel table. For each read-write column of Tunnel table, a Set Operation controlvalue is added in this object. Enumeration: 'unsetIlmSwap': 10, 'setDescription': 12, 'setNhlfe': 4, 'unsetHlspServerLsp': 15, 'createMplsTpTunnelEntry': 1, 'setTunnelQosPolicyName': 17, 'setMplsTpTunnelMode': 3, 'unsetNhlfe': 8, 'setIlmSwap': 6, 'deleteMplsTpTunnelEntry': 2, 'unsetIlmPop': 9, 'setHlspServerLsp': 13, 'setAssociateTunnel': 7, 'unsetHlspClientLsp': 16, 'unsetTunnelQosPolicyName': 18, 'setIlmPop': 5, 'setHlspClientLsp': 14, 'unsetAssociateTunnel': 11. |
sleMplsTpTunnelCfgControlStatus | 1.3.6.1.4.1.6296.101.16.14.1.2.2 | slecontrolstatustype | read-only |
This object displays the status of the configuration done. |
sleMplsTpTunnelCfgControlTimer | 1.3.6.1.4.1.6296.101.16.14.1.2.3 | gauge32 | read-write |
This object is based on the SLE style where a timer is configured for every control table. |
sleMplsTpTunnelCfgControlTimeStamp | 1.3.6.1.4.1.6296.101.16.14.1.2.4 | timeticks | read-only |
This object specifies the time at which the configuration is done. |
sleMplsTpTunnelCfgControlReqResult | 1.3.6.1.4.1.6296.101.16.14.1.2.5 | slecontrolrequestresulttype | read-only |
The standard result of the SET operation is stored here. |
sleMplsTpTunnelCfgControlName | 1.3.6.1.4.1.6296.101.16.14.1.2.6 | octet string | read-write |
The canonical name assigned to the tunnel. This name can be used to refer to the tunnel on the LSR's console port. If mplsTunnelIsIf is set to true then the ifName of the interface corresponding to this tunnel should have a value equal to SlemplsTunnelName. Also see the description of ifName in RFC 2863. |
sleMplsTpTunnelCfgControlId | 1.3.6.1.4.1.6296.101.16.14.1.2.7 | unsigned32 | read-write |
This object is used to set the tunnel Id . |
sleMplsTpTunnelCfgControlSrcIdType | 1.3.6.1.4.1.6296.101.16.14.1.2.8 | integer | read-write |
This object is used to set the ietf or itut type. Enumeration: 'ietf': 1, 'itut': 2. |
sleMplsTpTunnelCfgControlSrcGId | 1.3.6.1.4.1.6296.101.16.14.1.2.9 | unsigned32 | read-write |
This object is used to set the source Global-Id for IETF . |
sleMplsTpTunnelCfgControlSrcCc | 1.3.6.1.4.1.6296.101.16.14.1.2.10 | mplsccid | read-write |
This object is used to set the source CC-ID for ITUT. |
sleMplsTpTunnelCfgControlSrcIcc | 1.3.6.1.4.1.6296.101.16.14.1.2.11 | mplsiccid | read-write |
This object is used to set the Source ICC-ID for ITUT. |
sleMplsTpTunnelCfgControlSrcNodeId | 1.3.6.1.4.1.6296.101.16.14.1.2.12 | ipaddress | read-write |
This object is used to set the Source Node-Id for IETF and ITUT |
sleMplsTpTunnelCfgControlDestIdType | 1.3.6.1.4.1.6296.101.16.14.1.2.13 | integer | read-write |
This object is used to set the ietf or itut type. Enumeration: 'ietf': 1, 'itut': 2. |
sleMplsTpTunnelCfgControlDestGId | 1.3.6.1.4.1.6296.101.16.14.1.2.14 | unsigned32 | read-write |
This object is used to set the Destination Global-Id for IETF . |
sleMplsTpTunnelCfgControlDestCc | 1.3.6.1.4.1.6296.101.16.14.1.2.15 | mplsccid | read-write |
This object is used to set the Destination CC-ID for ITUT. |
sleMplsTpTunnelCfgControlDestIcc | 1.3.6.1.4.1.6296.101.16.14.1.2.16 | mplsiccid | read-write |
This object is used to set the Destination ICC-ID for ITUT. |
sleMplsTpTunnelCfgControlDestNodeId | 1.3.6.1.4.1.6296.101.16.14.1.2.17 | ipaddress | read-write |
This object is used to set the Destination NodeID for IETF and ITUT. |
sleMplsTpTunnelCfgControlMode | 1.3.6.1.4.1.6296.101.16.14.1.2.18 | integer | read-write |
This object is used to set the Tunnel mode . Enumeration: 'bidirectional': 2, 'unidirectional': 1. |
sleMplsTpTunnelCfgControlPath | 1.3.6.1.4.1.6296.101.16.14.1.2.19 | integer | read-write |
This object is used to Set the forward path and reverse path tunnel. Enumeration: 'forwardPath': 1, 'reversePath': 2. |
sleMplsTpTunnelCfgControlInLabel | 1.3.6.1.4.1.6296.101.16.14.1.2.20 | mplslabel | read-write |
This object is used to set the Inlabel. |
sleMplsTpTunnelCfgControlInInterface | 1.3.6.1.4.1.6296.101.16.14.1.2.21 | interfaceindexorzero | read-write |
This object is used to set the Ininterface index. |
sleMplsTpTunnelCfgControlOperation | 1.3.6.1.4.1.6296.101.16.14.1.2.22 | integer | read-write |
This object is used to set the operation of Tuunel Enumeration: 'push': 1, 'swap': 3, 'pop': 2. |
sleMplsTpTunnelCfgControlOutLabel | 1.3.6.1.4.1.6296.101.16.14.1.2.23 | mplslabel | read-write |
This object is used to set the outlabel. |
sleMplsTpTunnelCfgControlOutInterface | 1.3.6.1.4.1.6296.101.16.14.1.2.24 | interfaceindexorzero | read-write |
This object is used to set the outerinterface index. |
sleMplsTpTunnelCfgControlOutMacAddress | 1.3.6.1.4.1.6296.101.16.14.1.2.25 | macaddress | read-write |
This object is used to Set the Out MacAddress . |
sleMplsTpTunnelCfgControlAssociateTnlName | 1.3.6.1.4.1.6296.101.16.14.1.2.26 | octet string | read-write |
This object is used to Associated Forward tunnel and reverse tunnel with reverse tunnel name . |
sleMplsTpTunnelCfgControlDescription | 1.3.6.1.4.1.6296.101.16.14.1.2.27 | octet string | read-write |
Description. |
sleMplsTpTunnelCfgControlHlspSeverTunnelName | 1.3.6.1.4.1.6296.101.16.14.1.2.28 | octet string | read-write |
This object is used to set the server Tunnel name for associating server and client. |
sleMplsTpTunnelCfgControlQosPolicyName | 1.3.6.1.4.1.6296.101.16.14.1.2.29 | octet string | read-write |
This object is used to set the Qos Policy name. |