SHELF-MIB: View SNMP OID List / Download MIB

VENDOR: SAGEMCOM SAS


 Home MIB: SHELF-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 shelf 1.3.6.1.4.1.1038.150
The MIB module specific for ADR equipment
         adrHotReset 1.3.6.1.4.1.1038.150.1 sagemboolean read-write
Software hot reset when this variable is set to TRUE
         led 1.3.6.1.4.1.1038.150.2
             ledNumber 1.3.6.1.4.1.1038.150.2.1 integer read-only
Number of led in equipment.
             ledTable 1.3.6.1.4.1.1038.150.2.2 no-access
List of led in equipment.
                 ledEntry 1.3.6.1.4.1.1038.150.2.2.1 no-access
A particular led of the equipment.
                     ledIndex 1.3.6.1.4.1.1038.150.2.2.1.1 integer read-only
A unique value which identify a particular led.
                     ledPosition 1.3.6.1.4.1.1038.150.2.2.1.2 integer read-only
A reference to the associated Board on the equipment.
                     ledType 1.3.6.1.4.1.1038.150.2.2.1.3 ledtype read-only
Type of the Led.
                     ledStatus 1.3.6.1.4.1.1038.150.2.2.1.4 ledstatus read-only
Status of this Led.
         holdTime 1.3.6.1.4.1.1038.150.3
             adrFailHoldOffTime 1.3.6.1.4.1.1038.150.3.1 holdtime read-write
Failure hold off time : the time interval during which the defect is present and the failure is not raised
             adrFailHoldOnTime 1.3.6.1.4.1.1038.150.3.2 holdtime read-write
Failure hold on time : the time interval during which the defect is cleared and the failure is not
         board 1.3.6.1.4.1.1038.150.20
               boardNumber 1.3.6.1.4.1.1038.150.20.1 integer read-only
Number of board in equipment.
               boardTable 1.3.6.1.4.1.1038.150.20.2 no-access
List of board in equipment.
                   boardEntry 1.3.6.1.4.1.1038.150.20.2.1 no-access
A particular board of the equipment.
                       boardIndex 1.3.6.1.4.1.1038.150.20.2.1.1 integer read-only
A unique value which identify a particular slot. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to hardware. Each equipment maintain its own pool of values: ex ADR155c : A = 1, B = 2, ... M = 5, Fan = 6 ex ADR2500c: Fan = 1, PSU1 = 2, ...Trib1 = 8, Trib6= 13, Line1 = 14,... Switch2 = 17, Shelf = 18
                       boardSlotName 1.3.6.1.4.1.1038.150.20.2.1.2 displaystring read-only
A DisplayString which identify the name of a particular slot. Its value is fixed at equipment design time. It is usualy related to hardware ex ADR155c : A, B, ... Fan ex ADR2500c: Fan, CCU, CTRL, PSU1, ... TRIB5, .... SWITCH1, ...
                       boardExpectType 1.3.6.1.4.1.1038.150.20.2.1.3 integer read-write
A value which configure the expected type. If used, this one must be equal to one of existent boardListIndex for the considerated board. Otherwise, the value is set to 0. Known types are readable in boardListTable
                       boardInsertType 1.3.6.1.4.1.1038.150.20.2.1.4 integer read-only
When the inserted board doesn't match with the expexted board the boardMismatch failure is generated. The type of the card could be found in hardware inventory.
                       boardExpectFamily 1.3.6.1.4.1.1038.150.20.2.1.5 displaystring read-only
Board Family corresponding to the specified expected kind. This value is send by the equipment. ex ADR155c : ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
                       boardInsertFamily 1.3.6.1.4.1.1038.150.20.2.1.6 displaystring read-only
Board Family corresponding to the type of inserted board. ex ADR155c : ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
                       boardActive 1.3.6.1.4.1.1038.150.20.2.1.7 sagemboolean read-write
When the value of this field is set to false, the transmission of this board stop and the board could properly be extracted
                       boardFirstPortIndex 1.3.6.1.4.1.1038.150.20.2.1.8 integer read-only
If the card is a card with physical ports, then the value is the first index of a physical interface (SPI, PPI) in the mib SDH-ETS. Else, the value is 0.
                       boardProtectionType 1.3.6.1.4.1.1038.150.20.2.1.9 protectiontype read-write
The value of this field indicates the kind of wanted card protection. The default value is NONE. if value is changed in cardP(1)then an entry is created in cardpTable. But this table has to be completed (by setting the cardpReliefIndex,...) to obtain a configured protection. if value is changed in None(0)then the associated entry in cardpTable is deleted. Some cards don't accept any protection. In that case, the value of this field will remain to NONE
                       boardMonitor 1.3.6.1.4.1.1038.150.20.2.1.10 sagemboolean read-write
When the value of this field is set to false, the failure detection is stopped for this board.
                       boardFailure 1.3.6.1.4.1.1038.150.20.2.1.11 boardfailure read-only
Active failures on board
                       boardSeverity 1.3.6.1.4.1.1038.150.20.2.1.12 severity read-only
A reference to failure severity for boards.
                       boardMissingSev 1.3.6.1.4.1.1038.150.20.2.1.13 severity read-write
A reference to failure severity for boards.
                       boardMismatchSev 1.3.6.1.4.1.1038.150.20.2.1.14 severity read-write
A reference to failure severity for boards.
                       boardDefectiveSev 1.3.6.1.4.1.1038.150.20.2.1.15 severity read-write
A reference to failure severity for boards.
         boardList 1.3.6.1.4.1.1038.150.30
               boardListNumber 1.3.6.1.4.1.1038.150.30.1 integer read-only
Number of entry of the boardList Table
               boardListTable 1.3.6.1.4.1.1038.150.30.2 no-access
List of board type able to be managed by this equipment . In order to manage a new type, just insert the board and if the family match with a known family, this table will be expand automaticaly with the new type inserted The XX fist value defined ( with boardSlotName = Shelf = 18 for ADR2500c) is a list all possible type of boardInsertedType.
                   boardListEntry 1.3.6.1.4.1.1038.150.30.2.1 no-access
A particular boardList of the equipment.
                       boardListIndex 1.3.6.1.4.1.1038.150.30.2.1.1 integer read-only
A unique value.
                       boardListSlot 1.3.6.1.4.1.1038.150.30.2.1.2 integer read-only
A reference to the corresponding Slot.
                       boardListType 1.3.6.1.4.1.1038.150.30.2.1.3 displaystring read-only
In order to manage a new type, just insert the board and if the family match with a known family, this table will be expand automaticaly with the new type inserted. ex ADR155c : ex ADR2500c: 4S1.1, S4.1, L16.2, SWITCH, ...
         softInv 1.3.6.1.4.1.1038.150.40
               softInventoryNumber 1.3.6.1.4.1.1038.150.40.1 integer read-only
Number of entry of the softInventory Table
               softInventoryTable 1.3.6.1.4.1.1038.150.40.2 no-access
List of software inventory used
                   softInventoryEntry 1.3.6.1.4.1.1038.150.40.2.1 no-access
A particular boardList of the equipment.
                       softInventoryIndex 1.3.6.1.4.1.1038.150.40.2.1.1 integer read-only
A unique value.
                       softInventoryBoard 1.3.6.1.4.1.1038.150.40.2.1.2 integer read-only
A reference to the corresponding Slot. This variable is needed because some boards have their owns Applicative and Boot codes.
                       softInventoryType 1.3.6.1.4.1.1038.150.40.2.1.3 displaystring read-only
Indication of type software
                       softInventoryCode 1.3.6.1.4.1.1038.150.40.2.1.4 displaystring read-only
Indication of version code
                       softInventoryExt 1.3.6.1.4.1.1038.150.40.2.1.5 displaystring read-only
Indication of extension code. This one is not mandatory.
         hardInv 1.3.6.1.4.1.1038.150.50
               hardInventoryNumber 1.3.6.1.4.1.1038.150.50.1 integer read-only
Number of different hardware inventory in equipment.
               hardInventoryTable 1.3.6.1.4.1.1038.150.50.2 no-access
List of hardware inventory in equipment. A hardware inventory is a description associed to a particular card
                   hardInventoryEntry 1.3.6.1.4.1.1038.150.50.2.1 no-access
A particular tInv of the equipment.
                       hardInventoryIndex 1.3.6.1.4.1.1038.150.50.2.1.1 integer read-only
Index of the inventory entry that corresponds to a particular slot
                       hardInventoryBoard 1.3.6.1.4.1.1038.150.50.2.1.2 displaystring read-only
Family of card inserted in the slot
                       hardInventoryDescr 1.3.6.1.4.1.1038.150.50.2.1.3 displaystring read-only
The content of the inventory: a textual description
         laser 1.3.6.1.4.1.1038.150.100
                 laserNumber 1.3.6.1.4.1.1038.150.100.1 integer read-only
Number of optical interface in equipment.
                 laserTable 1.3.6.1.4.1.1038.150.100.2 no-access
List of synchronous physical interface in equipment.
                     laserEntry 1.3.6.1.4.1.1038.150.100.2.1 no-access
A particular synchronous physical interface of the equipment.
                         laserIndex 1.3.6.1.4.1.1038.150.100.2.1.1 integer read-only
                         laserTxEnable 1.3.6.1.4.1.1038.150.100.2.1.2 sagemboolean read-write
Enable(true) or disable(false) the laser output of the interface.
                         laserALSEnable 1.3.6.1.4.1.1038.150.100.2.1.3 sagemboolean read-write
Automatic Laser Shutdown enable(true) or disable(false). When enabled, this function cuts the laser output when a los is detected on input signal.
                         laserALSRestart2s 1.3.6.1.4.1.1038.150.100.2.1.4 sagemboolean read-write
Operator command to start a one shot emission during 2s.
                         laserALSRestart90s 1.3.6.1.4.1.1038.150.100.2.1.5 sagemboolean read-write
Operator command to start a one shot emission during 90s.
         eow 1.3.6.1.4.1.1038.150.120
                 eowNumber 1.3.6.1.4.1.1038.150.120.1 integer read-only
Number of EOW port in equipment.
                 eowTable 1.3.6.1.4.1.1038.150.120.2 no-access
List of EOW port in equipment.
                     eowEntry 1.3.6.1.4.1.1038.150.120.2.1 no-access
A particular EOW port of the equipment.
                         eowIndex 1.3.6.1.4.1.1038.150.120.2.1.1 integer read-only
A unique value which identify a particular EOW port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
                         eowName 1.3.6.1.4.1.1038.150.120.2.1.2 displaystring read-only
A text string which identifies the particular entry among the EOW port entries.
                         eowSrcType 1.3.6.1.4.1.1038.150.120.2.1.6 eowtype read-write
A reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection.
                         eowSrcPtr 1.3.6.1.4.1.1038.150.120.2.1.7 integer read-write
A reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection.
                         eowSinkType 1.3.6.1.4.1.1038.150.120.2.1.8 eowtype read-write
A reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection.
                         eowSinkPtr 1.3.6.1.4.1.1038.150.120.2.1.9 integer read-write
A reference to the object which sends the data flow to this interface. Usually the value is the oid of a vc12 or a connection.
                         eowClockMode 1.3.6.1.4.1.1038.150.120.2.1.10 eowclockmode read-write
Select the direction of the two external synchronisation lines.