Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 swEquipmentMIB 1.3.6.1.4.1.171.12.11
equipments MIB.
       swEquipment 1.3.6.1.4.1.171.12.11.1
           swEquipmentCapacity 1.3.6.1.4.1.171.12.11.1.1 bits read-only
Indicates the equipment capability supported in the system. Bits: 'stackingCapable': 3, 'tempteratureDetection': 2, 'redundantPowerCapable': 1, 'chassisCapable': 4, 'fanCapable': 0.
           swFanTrapState 1.3.6.1.4.1.171.12.11.1.4 integer read-write
Indicate the fan warning event trap state. Enumeration: 'disabled': 2, 'enabled': 1.
           swPowerTrapState 1.3.6.1.4.1.171.12.11.1.5 integer read-write
Indicate the power warning event trap state. Enumeration: 'disabled': 2, 'enabled': 1.
           swPowerTable 1.3.6.1.4.1.171.12.11.1.6 no-access
A list of power information values.
               swPowerEntry 1.3.6.1.4.1.171.12.11.1.6.1 no-access
An entry of power information values.
                   swPowerUnitIndex 1.3.6.1.4.1.171.12.11.1.6.1.1 integer read-only
Indicates the unit ID in the System.
                   swPowerID 1.3.6.1.4.1.171.12.11.1.6.1.2 integer read-only
Indicates ID of the power 1 : main power 2 : redundant power .
                   swPowerStatus 1.3.6.1.4.1.171.12.11.1.6.1.3 integer read-only
Indicates the current power status. lowVoltage : The voltage of the power unit is too low. overCurrent: The current of the power unit is too high. working : The power unit is working normally. fail : The power unit has failed. connect : The power unit is connected but not powered on. disconnect : The power unit is not connected. Enumeration: 'disconnect': 6, 'working': 3, 'overCurrent': 2, 'other': 0, 'connect': 5, 'fail': 4, 'lowVoltage': 1.
           swFanTable 1.3.6.1.4.1.171.12.11.1.7 no-access
A list of fan information values.
               swFanEntry 1.3.6.1.4.1.171.12.11.1.7.1 no-access
An entry of fan information values.
                   swFanUnitIndex 1.3.6.1.4.1.171.12.11.1.7.1.1 integer read-only
Indicates the unit ID in the System.
                   swFanID 1.3.6.1.4.1.171.12.11.1.7.1.2 integer read-only
Indicates the unit ID.
                   swFanStatus 1.3.6.1.4.1.171.12.11.1.7.1.3 integer read-only
Indicates the current fan status. speed-0 : If the fan function is normal and the fan does not spin due to the temperature not reaching the threshold, the status of the fan is speed 0. speed-low : Fan spin using the lowest speed. speed-middle: Fan spin using the middle speed. speed-high : Fan spin using the highest speed. Enumeration: 'speed-low': 4, 'speed-0': 3, 'working': 1, 'speed-middle': 5, 'other': 0, 'speed-high': 6, 'fail': 2.
                   swFanPostion 1.3.6.1.4.1.171.12.11.1.7.1.4 integer read-only
Indicates the position of the fan. Enumeration: 'cp': 5, 'other': 1, 'right': 3, 'back': 4, 'left': 2.
                   swFanNumber 1.3.6.1.4.1.171.12.11.1.7.1.5 integer read-only
Indicates the fan number.
                   swFanSpeed 1.3.6.1.4.1.171.12.11.1.7.1.6 integer read-only
Indicates the fan work speed(RPM).
           swTemperatureTable 1.3.6.1.4.1.171.12.11.1.8 no-access
A list of temperature values.
               swTemperatureEntry 1.3.6.1.4.1.171.12.11.1.8.1 no-access
An entry of temperature values.
                   swTemperatureUnitIndex 1.3.6.1.4.1.171.12.11.1.8.1.1 integer read-only
Indicates the unit ID in the System.
                   swTemperatureCurrent 1.3.6.1.4.1.171.12.11.1.8.1.2 integer read-only
The shelf current temperature.
                   swTemperatureHighThresh 1.3.6.1.4.1.171.12.11.1.8.1.3 integer read-write
The high threshold of shelf temperature.
                   swTemperatureLowThresh 1.3.6.1.4.1.171.12.11.1.8.1.4 integer read-write
The low threshold of shelf temperature.
           swUnitMgmt 1.3.6.1.4.1.171.12.11.1.9
               swUnitStackingVersion 1.3.6.1.4.1.171.12.11.1.9.1 integer read-only
This object indicates the version of this stacking system.
               swUnitMaxSupportedUnits 1.3.6.1.4.1.171.12.11.1.9.2 integer read-only
The maximum number of units that are supported in the system.
               swUnitNumOfUnit 1.3.6.1.4.1.171.12.11.1.9.3 integer read-only
The current number of units.
               swUnitMgmtTable 1.3.6.1.4.1.171.12.11.1.9.4 no-access
This table contains the unit information.
                   swUnitMgmtEntry 1.3.6.1.4.1.171.12.11.1.9.4.1 no-access
A list of management information for each unit in the system.
                       swUnitMgmtId 1.3.6.1.4.1.171.12.11.1.9.4.1.1 integer read-only
This object indicates the specific entry in the stacking/chassis table.
                       swUnitMgmtMacAddr 1.3.6.1.4.1.171.12.11.1.9.4.1.2 macaddress read-only
The MAC address of this unit.
                       swUnitMgmtStartPort 1.3.6.1.4.1.171.12.11.1.9.4.1.3 integer read-only
This object indicates the starting port of this unit.
                       swUnitMgmtPortRange 1.3.6.1.4.1.171.12.11.1.9.4.1.4 integer read-only
This object indicates the total ports of this unit.
                       swUnitMgmtFrontPanelLedStatus 1.3.6.1.4.1.171.12.11.1.9.4.1.5 octet string read-only
This object is a set of system LED indicators. The first four octets are defined as a system LED. The first LED is a power LED. The second LED in the stacking module is a master LED but in the chassis is a status LED. The third LED is a console LED. The fourth LED is an RPS (Redundancy Power Supply) LED. The other octets are the logical port LED (following dot1dBasePort ordering). Every two bytes are presented to a port. The first byte is presented as the link/activity LED. The second byte is presented as the speed LED. system LED: 01 = fail/error/non existence. 02 = work normal. link/activity LED : The most significant bit is used for blinking/solid: 8 = The LED blinks. The second most significant bit is used for link status: 1 = link fail. 2 = link pass. speed LED : 01 = 10Mbps. 02 = 100Mbps. 03 = 1000Mbps. The four remaining bits are currently unused and must be set to 0. Note: For the DGS-3700, the first five octets are defined as the system LED. The first LED is the power LED. The second LED is the console LED. The third LED is the RPS (Redundancy Power Supply) LED. The fourth LED is the management port LED. The fifth LED is the fan LED. For the DGS-3200-10 and DGS-3200-16, the first three octets are defined as the system LED. The first LED is the power LED. The second LED is the console LED. The third LED is the RPS (Redundancy Power Supply) LED. For the DGS-3200-24, the first three octets are defined as the system LED, the definition of the first three octets is the same as the DGS-3200-10 and DGS-3200-16, the fourth LED is the SD card LED. The following description is for the SD card LED: 01 = SD card is not present. 02 = SD card is present. 03 = fails to read/write SD card. 04 = read/write SD card successfully.
                       swUnitMgmtCtrlMode 1.3.6.1.4.1.171.12.11.1.9.4.1.6 integer read-write
This object indicates the stacking mode the user configured for the unit. This object can only be configured when the device is in standalone mode. other (1) - This object indicates the stacking mode that the user has configured for the unit. This object can only be configured when the device is in standalone mode. auto (2) - The system will auto-assign a stacking role to this unit to be: standalone(3), master(4), or slave(5). standalone (3) - The unit is forced to be in standalone mode. master (4) - The unit is forced to be in master mode. If this unit is selected to be a master, the unit can modify the configuration of the stacking system. slave (5) - The unit is forced to be in slave mode. If this unit is selected to be a slave, it can only view the configuration of the stacking system. Enumeration: 'auto': 2, 'other': 1, 'master': 4, 'stand-alone': 3, 'slave': 5.
                       swUnitMgmtCurrentMode 1.3.6.1.4.1.171.12.11.1.9.4.1.7 integer read-only
The current stacking role of this unit. Enumeration: 'slave': 5, 'backup-master': 6, 'auto': 2, 'stand-alone': 3, 'other': 1, 'master': 4.
                       swUnitMgmtVersion 1.3.6.1.4.1.171.12.11.1.9.4.1.8 displaystring read-only
This object indicates the version of this stacking unit.
                       swUnitMgmtModuleName 1.3.6.1.4.1.171.12.11.1.9.4.1.9 displaystring read-only
A textual string containing the stacking unit module name.
                       swUnitMgmtPromVersion 1.3.6.1.4.1.171.12.11.1.9.4.1.10 displaystring read-only
A textual string containing the PROM version of the stacking unit.
                       swUnitMgmtFirmwareVersion 1.3.6.1.4.1.171.12.11.1.9.4.1.11 displaystring read-only
A textual string containing the firmware version of the stacking unit.
                       swUnitMgmtHardwareVersion 1.3.6.1.4.1.171.12.11.1.9.4.1.12 displaystring read-only
A textual string containing the hardware version of the stacking unit.
                       swUnitMgmtPriority 1.3.6.1.4.1.171.12.11.1.9.4.1.13 integer read-write
The Priority of the stacking unit.
                       swUnitMgmtUserSetState 1.3.6.1.4.1.171.12.11.1.9.4.1.14 integer read-only
This object indicates the user set state of this unit. Enumeration: 'auto': 2, 'other': 1, 'user': 3.
                       swUnitMgmtExistState 1.3.6.1.4.1.171.12.11.1.9.4.1.15 integer read-only
The state of existence of this unit. Enumeration: 'no-exist': 2, 'exist': 1.
                       swUnitMgmtBoxId 1.3.6.1.4.1.171.12.11.1.9.4.1.16 integer read-write
The box ID of the stacking unit. When show, it shows the current box ID of this unit; When set, it sets the new box ID, and the new box ID will take effect after the next boot. Enumeration: 'box-11': 11, 'box-10': 10, 'box-12': 12, 'auto': 13, 'box-9': 9, 'box-8': 8, 'box-1': 1, 'box-3': 3, 'box-2': 2, 'box-5': 5, 'box-4': 4, 'box-7': 7, 'box-6': 6.
                       swUnitMgmtSerialNumber 1.3.6.1.4.1.171.12.11.1.9.4.1.17 displaystring read-only
A text string containing the serial number of the stacking unit.
               swUnitTopology 1.3.6.1.4.1.171.12.11.1.9.5 integer read-only
The stacking topology state. Enumeration: 'unstable': 5, 'duplex-ring': 3, 'star': 4, 'stand-alone': 1, 'duplex-chain': 2.
               swUnitStackMode 1.3.6.1.4.1.171.12.11.1.9.6 integer read-write
Indicates the stacking mode supported in the system. Enumeration: 'disabled': 2, 'enabled': 1.
               swUnitStackForceMasterRole 1.3.6.1.4.1.171.12.11.1.9.7 integer read-write
Indicates the stack force master role mode supported in the system. Enumeration: 'disabled': 2, 'enabled': 1.
               swUnitStackTrapState 1.3.6.1.4.1.171.12.11.1.9.8 integer read-write
Indicates the stacking trap state. Enumeration: 'disabled': 2, 'enabled': 1.
               swUnitStackLogState 1.3.6.1.4.1.171.12.11.1.9.9 integer read-write
Indicates the stacking log state. Enumeration: 'disabled': 2, 'enabled': 1.
           swExternalAlarmTable 1.3.6.1.4.1.171.12.11.1.10 no-access
A list of the status of each of the alarm channels by this agent.
                 swExternalAlarmEntry 1.3.6.1.4.1.171.12.11.1.10.1 no-access
An entry containing objects with the status of each alarm channel.
                     swExternalAlarmChannel 1.3.6.1.4.1.171.12.11.1.10.1.1 integer read-only
The number of the alarm channel.
                     swExternalAlarmMessage 1.3.6.1.4.1.171.12.11.1.10.1.2 displaystring read-write
Used to configure the alarm message when an alarm occurs on this channel. If no alarm message is configured on this channel, a default alarm message will be generated.
                     swExternalAlarmStatus 1.3.6.1.4.1.171.12.11.1.10.1.3 integer read-only
Shows the current status of each alarm channel. Enumeration: 'alarming': 1, 'normal': 2.
           swEquipmentPowerSaving 1.3.6.1.4.1.171.12.11.1.11
                 swEquipPowerSavingLinkDetectState 1.3.6.1.4.1.171.12.11.1.11.1 integer read-write
Indicates the equipment reduced power consumption state. Enumeration: 'disabled': 2, 'enabled': 1.
                 swEquipPowerSavingLenDetect 1.3.6.1.4.1.171.12.11.1.11.2 integer read-write
Indicates the equipment reduced power consumption state with a link partner. Enumeration: 'disabled': 2, 'enabled': 1.
                 swEquipPowerSavingHiberState 1.3.6.1.4.1.171.12.11.1.11.3 integer read-write
This object indicates the power saving state of system hibernation. Enumeration: 'disabled': 2, 'enabled': 1.
                 swEquipPowerSavingPortLEDState 1.3.6.1.4.1.171.12.11.1.11.4 integer read-write
This object indicates the power saving state of port LED. Enumeration: 'disabled': 2, 'enabled': 1.
                 swEquipPowerSavingPortState 1.3.6.1.4.1.171.12.11.1.11.5 integer read-write
This object indicates the power saving state of port. Enumeration: 'disabled': 2, 'enabled': 1.
                 swEquipPowerSavingScheduleCtrl 1.3.6.1.4.1.171.12.11.1.11.6
                     swEquipPowerSavingHibernationTable 1.3.6.1.4.1.171.12.11.1.11.6.1 no-access
A list of the system hibernation configurations of the power saving.
                         swEquipPowerSavingHibernationEntry 1.3.6.1.4.1.171.12.11.1.11.6.1.1 no-access
An entry containing the system hibernation configurations of the power saving.
                             swEquipPowerSavingHiberRowStatus 1.3.6.1.4.1.171.12.11.1.11.6.1.1.100 rowstatus read-only
This object indicates the status of this entry.
                     swEquipPowerSavingPortLedTable 1.3.6.1.4.1.171.12.11.1.11.6.2 no-access
A list of the port LED configurations of the power saving.
                         swEquipPowerSavingPortLedEntry 1.3.6.1.4.1.171.12.11.1.11.6.2.1 no-access
An entry containing the port LED configurations of the power saving.
                             swEquipPowerSavingPortLedRowStatus 1.3.6.1.4.1.171.12.11.1.11.6.2.1.100 rowstatus read-only
This object indicates the status of this entry.
                     swEquipPowerSavingPortTable 1.3.6.1.4.1.171.12.11.1.11.6.3 no-access
A list of the port configurations of the power saving.
                         swEquipPowerSavingPortEntry 1.3.6.1.4.1.171.12.11.1.11.6.3.1 no-access
An entry containing the port configurations of the power saving.
                             swEquipPowerSavingPortIndex 1.3.6.1.4.1.171.12.11.1.11.6.3.1.1 integer no-access
Indicates the module's port number.(1..Max port number in the module).
                             swEquipPowerSavingPortRowStatus 1.3.6.1.4.1.171.12.11.1.11.6.3.1.100 rowstatus read-only
This object indicates the status of this entry.
           swEquipmentTemperatureCtrl 1.3.6.1.4.1.171.12.11.1.12
                 swTemperatureTrapState 1.3.6.1.4.1.171.12.11.1.12.1 integer read-write
This object can enable or disable the warning temperature trap. Enumeration: 'disabled': 2, 'enabled': 1.
                 swTemperatureLogState 1.3.6.1.4.1.171.12.11.1.12.2 integer read-write
This object can enable or disable the warning temperature log. Enumeration: 'disabled': 2, 'enabled': 1.
           swEquipmentLEDCtrl 1.3.6.1.4.1.171.12.11.1.13
                 swEquipmentPortLEDState 1.3.6.1.4.1.171.12.11.1.13.1 integer read-write
This object indicates the LED admin state of all ports. Enumeration: 'disabled': 2, 'enabled': 1.
           swExternalAlarmStackingTable 1.3.6.1.4.1.171.12.11.1.15 no-access
A list of the status of each of the alarm channels by this agent.
                 swExternalAlarmStackingEntry 1.3.6.1.4.1.171.12.11.1.15.1 no-access
An entry containing objects with the status of each alarm channel.
                     swExternalAlarmStackingUnitIndex 1.3.6.1.4.1.171.12.11.1.15.1.1 integer no-access
Indicates the unit ID in the System..
                     swExternalAlarmStackingChannel 1.3.6.1.4.1.171.12.11.1.15.1.2 integer no-access
The number of the alarm channel.
                     swExternalAlarmStackingMessage 1.3.6.1.4.1.171.12.11.1.15.1.3 displaystring read-write
Used to configure the alarm message when an alarm occurs on this channel. If no alarm message is configured on this channel, a default alarm message will be generated.
                     swExternalAlarmStackingStatus 1.3.6.1.4.1.171.12.11.1.15.1.4 integer read-only
Shows the current status of each alarm channel. Enumeration: 'alarming': 1, 'normal': 2.
       swEquipmentNotify 1.3.6.1.4.1.171.12.11.2
           swEquipmentNotifyMgmt 1.3.6.1.4.1.171.12.11.2.1
               swEquipUnitNotifyMgmt 1.3.6.1.4.1.171.12.11.2.1.1
                   swUnitInsertSeverity 1.3.6.1.4.1.171.12.11.2.1.1.1 agentnotifylevel read-write
Indicates the swUnitInsert detection level.
                   swUnitRemoveSeverity 1.3.6.1.4.1.171.12.11.2.1.1.2 agentnotifylevel read-write
Indicates the swUnitRemove detection level.
                   swUnitFailureSeverity 1.3.6.1.4.1.171.12.11.2.1.1.3 agentnotifylevel read-write
Indicates the swUnitFailure detection level.
               swEquipPowerNotifyMgmt 1.3.6.1.4.1.171.12.11.2.1.2
                   swPowerStatusChgSeverity 1.3.6.1.4.1.171.12.11.2.1.2.1 agentnotifylevel read-write
Indicates the swPowerStatusChg detection level.
                   swPowerFailureSeverity 1.3.6.1.4.1.171.12.11.2.1.2.2 agentnotifylevel read-write
Indicates the swPowerFailure detection level.
                   swPowerRecoverSeverity 1.3.6.1.4.1.171.12.11.2.1.2.3 agentnotifylevel read-write
Indicates the swPowerRecover detection level.
               swEquipFanNotifyMgmt 1.3.6.1.4.1.171.12.11.2.1.3
                   swFanFailureSeverity 1.3.6.1.4.1.171.12.11.2.1.3.1 agentnotifylevel read-write
Indicates the swFanFailure detection level.
                   swFanRecoverSeverity 1.3.6.1.4.1.171.12.11.2.1.3.2 agentnotifylevel read-write
Indicates the swFanRecover detection level.
               swEquipTemperatureNotifyMgmt 1.3.6.1.4.1.171.12.11.2.1.4
                   swHighTemperatureSeverity 1.3.6.1.4.1.171.12.11.2.1.4.1 agentnotifylevel read-write
Indicates the swHighTemperature detection level.
                   swHighTemperatureRecoverSeverity 1.3.6.1.4.1.171.12.11.2.1.4.2 agentnotifylevel read-write
Indicates the swHighTemperatureRecover detection level.
                   swLowTemperatureSeverity 1.3.6.1.4.1.171.12.11.2.1.4.3 agentnotifylevel read-write
Indicates the swLowTemperature detection level.
                   swLowTemperatureRecoverSeverity 1.3.6.1.4.1.171.12.11.2.1.4.4 agentnotifylevel read-write
Indicates the swLowTemperatureRecover detection level.
           swEquipmentNotification 1.3.6.1.4.1.171.12.11.2.2
               swEquipUnitNotification 1.3.6.1.4.1.171.12.11.2.2.1
                   swEquipUnitNotifyPrefix 1.3.6.1.4.1.171.12.11.2.2.1.0
                       swUnitInsert 1.3.6.1.4.1.171.12.11.2.2.1.0.1
Unit Hot Insert notification.
                       swUnitRemove 1.3.6.1.4.1.171.12.11.2.2.1.0.2
Unit Hot Remove notification.
                       swUnitFailure 1.3.6.1.4.1.171.12.11.2.2.1.0.3
Unit Failure notification.
                       swUnitTPChange 1.3.6.1.4.1.171.12.11.2.2.1.0.4
The stacking topology change notification.
                       swUnitRoleChange 1.3.6.1.4.1.171.12.11.2.2.1.0.5
The stacking unit role change notification.
               swEquipPowerNotification 1.3.6.1.4.1.171.12.11.2.2.2
                   swEquipPowerNotifyPerfix 1.3.6.1.4.1.171.12.11.2.2.2.0
                       swPowerStatusChg 1.3.6.1.4.1.171.12.11.2.2.2.0.1
Power Status change notification. The notification is issued when the swPowerStatus changes in the following cases: lowVoltage -> overCurrent. lowVoltage -> working. lowVoltage -> disconnect. lowVoltage -> connect. overCurrent -> lowVoltage. overCurrent -> working. overCurrent -> disconnect. overCurrent -> connect. working -> lowVoltage. working -> overCurrent. working -> connect. working -> disconnect. fail -> connect. fail -> disconnect. connect -> lowVoltage. connect -> overCurrent. connect -> working. connect -> disconnect. disconnect -> lowVoltage. disconnect -> overCurrent. disconnect -> working. disconnect -> connect.
                       swPowerFailure 1.3.6.1.4.1.171.12.11.2.2.2.0.2
Power Failure notification. The notification is issued when the swPowerStatus changes in the following cases: lowVoltage -> fail. overCurrent -> fail. working -> fail. connect -> fail. disconnect -> fail.
                       swPowerRecover 1.3.6.1.4.1.171.12.11.2.2.2.0.3
Power Recover notification. The notification is issued when the swPowerStatus changes in the following cases: fail -> lowVoltage. fail -> overCurrent. fail -> working.
               swEquipFanNotification 1.3.6.1.4.1.171.12.11.2.2.3
                   swEquipFanNotifyPrefix 1.3.6.1.4.1.171.12.11.2.2.3.0
                       swFanFailure 1.3.6.1.4.1.171.12.11.2.2.3.0.1
Fan Failure notification.
                       swFanRecover 1.3.6.1.4.1.171.12.11.2.2.3.0.2
Fan Recover notification.
               swEquipTemperatureNotification 1.3.6.1.4.1.171.12.11.2.2.4
                   swEquipTemperatureNotifyPrefix 1.3.6.1.4.1.171.12.11.2.2.4.0
                       swHighTemperature 1.3.6.1.4.1.171.12.11.2.2.4.0.1
High Temperature notification.
                       swHighTemperatureRecover 1.3.6.1.4.1.171.12.11.2.2.4.0.2
High Temperature notification.
                       swLowTemperature 1.3.6.1.4.1.171.12.11.2.2.4.0.3
Low Temperature notification.
                       swLowTemperatureRecover 1.3.6.1.4.1.171.12.11.2.2.4.0.4
Low Temperature notification.
               swEquipExternalAlarmNotification 1.3.6.1.4.1.171.12.11.2.2.5
                   swEquipExternalAlarmNotifyPrefix 1.3.6.1.4.1.171.12.11.2.2.5.0
                       swExternalAlarm 1.3.6.1.4.1.171.12.11.2.2.5.0.1
The notice of an Alarm in the specified channel.
                       swExternalAlarmStacking 1.3.6.1.4.1.171.12.11.2.2.5.0.2
The notice of an Alarm in the specified channel.
           swNotificationBindings 1.3.6.1.4.1.171.12.11.2.3
               swEquipTemperNotifyBindings 1.3.6.1.4.1.171.12.11.2.3.1
                   swTemperSensorID 1.3.6.1.4.1.171.12.11.2.3.1.1 integer no-access
This object indicates the ID of the temperature sensor in the unit.
               swEquipUnitNotifyBindings 1.3.6.1.4.1.171.12.11.2.3.2
                   swStackTopologyType 1.3.6.1.4.1.171.12.11.2.3.2.1 integer no-access
This object indicates the MAC address of the switch. Enumeration: 'ring': 2, 'chain': 1.
                   swStackRoleChangeType 1.3.6.1.4.1.171.12.11.2.3.2.2 integer no-access
This object indicates the role information of the switch. Enumeration: 'slave-to-master': 2, 'backup-to-master': 1.