SDH-ETS-MIB: View SNMP OID List / Download MIB
VENDOR: SAGEMCOM SAS
Home | MIB: SDH-ETS-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
sdhEts | 1.3.6.1.4.1.1038.110 |
The MIB module defines SDH transmition part of an equipment This MIB use the logical model defined in ETSI ETS 300 304. ETS 300 304 (February 1997) defines the SDH information model for the Network Element. This MIB refers to SHELF-MIB for the definition of the Board that supports the interface. This MIB is refered by XCON-MIB that uses the definition of termination point to create cross connection. This MIB also define configuration of the different SDH blocs such as alarm monitoring and severity and give the current status of the termination point. |
||
spiTTP | 1.3.6.1.4.1.1038.110.10 | |||
spiTTPNumber | 1.3.6.1.4.1.1038.110.10.1 | integer | read-only |
Number of synchronous physical interface in equipment = number of element in spiTTPTable |
spiTTPTable | 1.3.6.1.4.1.1038.110.10.2 | no-access |
List of synchronous physical interface in equipment. |
|
1.3.6.1.4.1.1038.110.10.2.1 | no-access |
A particular synchronous physical interface of the equipment. |
||
spiTTPIndex | 1.3.6.1.4.1.1038.110.10.2.1.1 | integer | read-only |
A unique value which identify a particular synchronous physical interface. The value of this index is a constant value assigned to an entry at equipment design time. It is usualy related to harware. Exemple: For ADR155c equipement index are 1,64,127,190 for STM1 interfaces. For ADR2500c equipement index are: 1,1009,2017,3025,4033,5041,6049,7057 for 8 STM16 or 8 STM4, 1,253,505,757 1009,1261,1513,1765 | 2017,2269,2521,2773 3025,3277,3529,3781 | --> for 8 (4*STM1) 4033,4285,4537,4789 5041,5293,5545,5797 | 6049,6301,6553,6805 7057,7309,7561,7813 | |
spiTTPStmLevel | 1.3.6.1.4.1.1038.110.10.2.1.2 | stmlevel | read-only |
The STM-n level of the interface. |
spiTTPType | 1.3.6.1.4.1.1038.110.10.2.1.3 | spittptype | read-only |
The kind of the interface: electrical or optical |
spiTTPName | 1.3.6.1.4.1.1038.110.10.2.1.4 | displaystring | read-write |
A text string which identifies the particular entry among the synchronous physical interface entries. |
spiTTPBoardIndex | 1.3.6.1.4.1.1038.110.10.2.1.5 | integer | read-only |
Index of the Board that supports the physical acces of this interface. This index refers to another MIB that defines the board |
spiTTPBoardAcces | 1.3.6.1.4.1.1038.110.10.2.1.6 | integer | read-only |
Friendly Index of the physical acces on the Board that supports the interface |
spiTTPMonitor | 1.3.6.1.4.1.1038.110.10.2.1.7 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this synchronous physical interface. |
spiTTPFailure | 1.3.6.1.4.1.1038.110.10.2.1.8 | spittpfailure | read-only |
Active failures on synchronous physical interface |
spiTTPSeverity | 1.3.6.1.4.1.1038.110.10.2.1.9 | severity | read-only |
Severity associed with active failure for synchronous physical interface. |
spiTTPLoopback | 1.3.6.1.4.1.1038.110.10.2.1.10 | loopback | read-write |
This field gives the active loopback status on the synchronous physical interface. When its value is `line' the data flow recieved from the port side is sent back to the line. When its value is `equipment' the data flow recieved form equipment side is send back. The field can be set to a particular loopback value, even if there no garantee that the loopback is really done. The real loopback status of the interface must be checked in the response. The loopback can be cleared by the equipment when it cannot remain for any reason. |
spiTTPLos | 1.3.6.1.4.1.1038.110.10.2.1.20 | severity | read-write |
Severity associed with Loss Of Signal failure for synchronous physical interface. |
spiTTPTf | 1.3.6.1.4.1.1038.110.10.2.1.21 | severity | read-write |
Severity associed with Tranmit Fail failure for synchronous physical interface. |
rsTTP | 1.3.6.1.4.1.1038.110.20 | |||
rsTTPTable | 1.3.6.1.4.1.1038.110.20.2 | no-access |
List of regenerator section terminaison in equipment. |
|
1.3.6.1.4.1.1038.110.20.2.1 | no-access |
A particular regenerator section terminaison of the equipment. |
||
rsTTPIndex | 1.3.6.1.4.1.1038.110.20.2.1.1 | integer | read-only |
A unique value which identify a particular synchronous physical interface. The value of this index is always the same as spiTTPIndex. |
rsTTPMonitor | 1.3.6.1.4.1.1038.110.20.2.1.2 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this regenerator section terminaison. |
rsTTPName | 1.3.6.1.4.1.1038.110.20.2.1.3 | displaystring | read-write |
A text string which identifies the particular entry among the regenerator section terminaison entries. |
rsTTPFailure | 1.3.6.1.4.1.1038.110.20.2.1.4 | rsttpfailure | read-only |
Active failures on regenerator section terminaison |
rsTTPSeverity | 1.3.6.1.4.1.1038.110.20.2.1.5 | severity | read-only |
Severity associed active Failure for regenerator section terminaison. |
rsTTPEOWMode | 1.3.6.1.4.1.1038.110.20.2.1.8 | eowmode | read-only |
Mode used for EOW: Codir or contradir Master |
rsTTPE1SrcPointer | 1.3.6.1.4.1.1038.110.20.2.1.9 | integer | read-only |
A reference to the object which sends the data flow to E1 RSOH byte (index in X21 table) Usualy E1 carries X21 EOW (engineering order wire) data and thus the pointer s value reference a mib X21 port entry. Zero indicates not used |
rsTTPF1SrcPointer | 1.3.6.1.4.1.1038.110.20.2.1.10 | integer | read-only |
A reference to the object which sends the data flow to F1 RSOH byte.Zero indicates not used |
rsTTPSesThreshold | 1.3.6.1.4.1.1038.110.20.2.1.11 | integer | read-only |
The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
rsTTPEOWByteLine | 1.3.6.1.4.1.1038.110.20.2.1.12 | integer | read-write |
The line determines the SOH byte selected for Engineering Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and finish with 5 lines of MSOH (5,6,7,8,9) E1 is on line 2 column 4. Zero indicates EOW not used, value different from 2 means EOW not on E1 |
rsTTPEOWByteColumn | 1.3.6.1.4.1.1038.110.20.2.1.13 | integer | read-write |
The column determines the SOH byte selected for Engineering Order Wire: SOH is composed of Col [1,9] E1 is on line 2 column 4. Zero indicates EOW not used, value different from 4 means EOW not on E1 |
rsTTPLof | 1.3.6.1.4.1.1038.110.20.2.1.20 | severity | read-write |
Severity associed with Loss Of Frame failure for regenerator section terminaison. |
rsCTP | 1.3.6.1.4.1.1038.110.25 | |||
msTTP | 1.3.6.1.4.1.1038.110.30 | |||
msTTPTable | 1.3.6.1.4.1.1038.110.30.2 | no-access |
List of multiplex section terminaison in equipment. |
|
1.3.6.1.4.1.1038.110.30.2.1 | no-access |
A particular multiplex section terminaison of the equipment. |
||
msTTPIndex | 1.3.6.1.4.1.1038.110.30.2.1.1 | integer | read-only |
A unique value which identify a particular synchronous physical interface. The value of this index is always the same as spiTTPIndex |
msTTPProtectionType | 1.3.6.1.4.1.1038.110.30.2.1.2 | protectiontype | read-write |
The value of this field indicates the kind of wanted multiplex section protection. The default value is NONE. if value is changed in msp(1) or msSPRing(2) then (if it's possible) an entry is created respectivelly in mspTable or msSPRingTable. But these tables have to be completed to obtain a configured protection. If value is changed in None(0)then the associated entry in mspTable or msSPRingTable is deleted (if it's possible). |
msTTPMonitor | 1.3.6.1.4.1.1038.110.30.2.1.3 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this multiplex section terminaison. |
msTTPName | 1.3.6.1.4.1.1038.110.30.2.1.4 | displaystring | read-write |
A text string which identifies the particular entry among the multiplex section terminaison entries. |
msTTPFailure | 1.3.6.1.4.1.1038.110.30.2.1.5 | msttpfailure | read-only |
Active failures on multiplex section terminaison |
msTTPSeverity | 1.3.6.1.4.1.1038.110.30.2.1.6 | severity | read-only |
Severity associed with active failures on multiplex section terminaison. |
msTTPEOWMode | 1.3.6.1.4.1.1038.110.30.2.1.7 | eowmode | read-only |
Mode used for EOW: Codir or contradir Master |
msTTPE2SrcPointer | 1.3.6.1.4.1.1038.110.30.2.1.8 | integer | read-only |
A reference to the object which sends the data flow to E2 MSOH byte. Usualy E2 carries X21 EOW (engineering order wire) data. The reference is an index in X21 table.Zero indicates not used |
msTTPEOWByteLine | 1.3.6.1.4.1.1038.110.30.2.1.9 | integer | read-write |
The line determines the SOH byte selected for Engineering Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and finish with 5 lines of MSOH (5,6,7,8,9) E2 is on line 9 column 7. Zero indicates not used, value different from 9 means EOW not on E2 |
msTTPEOWByteColumn | 1.3.6.1.4.1.1038.110.30.2.1.10 | integer | read-write |
The column determines the SOH byte selected for Engineering Order Wire: SOH is composed of Col [1,9] E2 is on line 9 column 7. Zero indicates EOW not used, value different from 7 means EOW not on E2 |
msTTPMonEber | 1.3.6.1.4.1.1038.110.30.2.1.11 | sagemboolean | read-write |
If the value of this field is true, the eber is monitored and is used as MSP and SETS criterium. If this defect is detected, an ais signal is send downstream and rdi upstream. |
msTTPSdThreshold | 1.3.6.1.4.1.1038.110.30.2.1.12 | integer | read-write |
A Signal Degrade failure is declared if the error block rate is greater than 1E(-mstSdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - mstSdThreshold). |
msTTPSesThreshold | 1.3.6.1.4.1.1038.110.30.2.1.13 | integer | read-only |
The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
msTTPEber | 1.3.6.1.4.1.1038.110.30.2.1.20 | severity | read-write |
Severity associed with Excecive Bit Error Rate failure for multiplex section terminaison. |
msTTPSd | 1.3.6.1.4.1.1038.110.30.2.1.21 | severity | read-write |
Severity associed with Signal Degrade failure for multiplex section terminaison. |
msTTPRdi | 1.3.6.1.4.1.1038.110.30.2.1.22 | severity | read-write |
Severity associed with Remote Defect Indication failure for multiplex section terminaison. |
msCTP | 1.3.6.1.4.1.1038.110.35 | |||
msa | 1.3.6.1.4.1.1038.110.60 | |||
msaTable | 1.3.6.1.4.1.1038.110.60.2 | no-access |
List of multiplex section adaptation in equipment. |
|
1.3.6.1.4.1.1038.110.60.2.1 | no-access |
A particular multiplex section adaptation of the equipment. |
||
msaIndex | 1.3.6.1.4.1.1038.110.60.2.1.1 | integer | read-only |
Index of a particular entry among the multiplex section adaptation entries. |
msaSTMLevel | 1.3.6.1.4.1.1038.110.60.2.1.2 | stmlevel | read-only |
The STM-n level of the multiplex section adaptation. |
msaSinkType | 1.3.6.1.4.1.1038.110.60.2.1.3 | msasinktype | read-only |
Type of msa sinkPointer: msa or mst |
msaSinkPointer | 1.3.6.1.4.1.1038.110.60.2.1.4 | integer | read-only |
A reference to the object which sends the data flow to this function on synchronous port interface side. In most equipments, this value cannot be changed and points to the MST it is hard wired with. |
msaName | 1.3.6.1.4.1.1038.110.60.2.1.5 | displaystring | read-write |
A text string which identifies the particular entry among the multiplex section adaptation entries. |
msaSrc1Type | 1.3.6.1.4.1.1038.110.60.2.1.6 | msasrctype | read-only |
Type of msa srcPointer: msa or vc4 |
msaSrc2Type | 1.3.6.1.4.1.1038.110.60.2.1.7 | msasrctype | read-only |
Type of msa srcPointer: msa or vc4 |
msaSrc3Type | 1.3.6.1.4.1.1038.110.60.2.1.8 | msasrctype | read-only |
Type of msa srcPointer: msa or vc4 |
msaSrc4Type | 1.3.6.1.4.1.1038.110.60.2.1.9 | msasrctype | read-only |
Type of msa srcPointer: msa or vc4 |
msaSrc1Pointer | 1.3.6.1.4.1.1038.110.60.2.1.10 | integer | read-only |
Table index of the object which sends the data flow to this function on equipment side. For STM16: 4 pseudo STM4 (group of 4STM1) identified by their index in msaTable. Theses indexes must be differents to thoses used by the MST Table. For STM4: 4 VC4 identified by their index in vc4Table For STM1: 1 VC4 identified by its index in vc4Table |
msaSrc2Pointer | 1.3.6.1.4.1.1038.110.60.2.1.11 | integer | read-only |
A reference to the object which sends the data flow to this function on equipment side. In most equipments, this value cannot be changed and points to the VC4 function it is hard wired with. |
msaSrc3Pointer | 1.3.6.1.4.1.1038.110.60.2.1.12 | integer | read-only |
A reference to the object which sends the data flow to this function on equipment side. In most equipments, this value cannot be changed and points to the VC4 function it is hard wired with. |
msaSrc4Pointer | 1.3.6.1.4.1.1038.110.60.2.1.13 | integer | read-only |
A reference to the object which sends the data flow to this function on equipment side. In most equipments, this value cannot be changed and points to the VC4 function it is hard wired with. |
au4CTP | 1.3.6.1.4.1.1038.110.70 | |||
au4CTPNumber | 1.3.6.1.4.1.1038.110.70.1 | integer | read-only |
Number of administrative unit order 4 in equipment. |
au4CTPTable | 1.3.6.1.4.1.1038.110.70.2 | no-access |
List of administrative unit order 4 in equipment which are availables for new connection or used in connection. In that case, an indication on the connection type is set into the au4CTPCnxType Variable. All au4 CTP, which are made up of lower connection level (tu3 or tu12), are set to 'used' value with 'tu' type connection indication . |
|
1.3.6.1.4.1.1038.110.70.2.1 | no-access |
A particular administrative unit order 4 of the equipment. |
||
au4CTPIndex | 1.3.6.1.4.1.1038.110.70.2.1.1 | integer | read-only |
A unique value which identify a particular administrative unit order 4. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
au4CTPStatus | 1.3.6.1.4.1.1038.110.70.2.1.2 | ctpstatus | read-only |
au4 connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP |
au4CTPCnxType | 1.3.6.1.4.1.1038.110.70.2.1.3 | au4ctpcnxtype | read-only |
au4 connection Type: none, au4, au4-4c,au4-16c,tu. The 'none' value is used when there is no connection with this output CTP |
au4CTPName | 1.3.6.1.4.1.1038.110.70.2.1.4 | displaystring | read-write |
A text string which identifies the particular entry among the administrative unit order 4 entries. |
au4CTPMonitor | 1.3.6.1.4.1.1038.110.70.2.1.6 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this administrative unit order 4. |
au4CTPFailure | 1.3.6.1.4.1.1038.110.70.2.1.7 | au4ctpfailure | read-only |
Active failures on administrative unit order 4 |
au4CTPSeverity | 1.3.6.1.4.1.1038.110.70.2.1.8 | severity | read-only |
A reference to failure severity for administrative unit order 4. |
au4CTPAis | 1.3.6.1.4.1.1038.110.70.2.1.20 | severity | read-write |
Severity associed with Alarme Indication Signal failure for administrative unit order 4. |
au4CTPLop | 1.3.6.1.4.1.1038.110.70.2.1.21 | severity | read-write |
Severity associed with Loss Of Pointer failure for administrative unit order 4. |
au4CTPLom | 1.3.6.1.4.1.1038.110.70.2.1.22 | severity | read-write |
Severity associed with Loss Of MultiFrame failure for administrative unit order 4. |
vc4TTP | 1.3.6.1.4.1.1038.110.100 | |||
vc4TTPNumber | 1.3.6.1.4.1.1038.110.100.1 | integer | read-only |
Number of virtual container order 4 in equipment. |
vc4TTPTable | 1.3.6.1.4.1.1038.110.100.2 | no-access |
List of virtual container order 4 in equipment.The number of records depends on the kinds of configured boards |
|
1.3.6.1.4.1.1038.110.100.2.1 | no-access |
A particular virtual container order 4 of the equipment. |
||
vc4TTPIndex | 1.3.6.1.4.1.1038.110.100.2.1.1 | integer | read-only |
A unique value which identify a particular virtual container order 4. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
vc4TTPSinkPointer | 1.3.6.1.4.1.1038.110.100.2.1.2 | integer | read-only |
A reference to the object which sends the data flow to this function on synchronous or unsynchronous port interface side. This pointer corresponds to an index in the msTTPTable or nspiTTPTable. |
vc4TTPSinkType | 1.3.6.1.4.1.1038.110.100.2.1.3 | vc4ttpsinktype | read-only |
A reference to the kind of the sink Pointer |
vc4TTPName | 1.3.6.1.4.1.1038.110.100.2.1.5 | displaystring | read-write |
A text string which identifies the particular entry among the virtual container order 4 entries. |
vc4TTPMonitor | 1.3.6.1.4.1.1038.110.100.2.1.6 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this virtual container order 4. |
vc4TTPFailure | 1.3.6.1.4.1.1038.110.100.2.1.7 | vc4ttpfailure | read-only |
Active failures on virtual container order 4 |
vc4TTPSeverity | 1.3.6.1.4.1.1038.110.100.2.1.8 | severity | read-only |
A reference to failure severity for virtual container order 4. |
vc4TTPTraceMode | 1.3.6.1.4.1.1038.110.100.2.1.9 | vc4ttptracemode | read-write |
Configuration of the pathTrace length (1 byte or 16 bytes). |
vc4TTPPathTraceExpected | 1.3.6.1.4.1.1038.110.100.2.1.11 | octet string | read-write |
The path trace is a user string that always follows the vc4. If the value the received path trace does not match this one, a tim (Trail Identifier Mismatch) failure is issued. The value `? ' match all possible received path trace. |
vc4TTPPathTraceSent | 1.3.6.1.4.1.1038.110.100.2.1.12 | octet string | read-write |
The path trace is a user string that always follows the vc4. The value of this field is sent in j1 byte as path trace for this vc4. The default value is `all 0'. |
vc4TTPPathTraceReceived | 1.3.6.1.4.1.1038.110.100.2.1.13 | octet string | read-only |
The path trace is a user string that always follows the vc4. The value is the actual path trace received in j1 byte |
vc4TTPLabelExpected | 1.3.6.1.4.1.1038.110.100.2.1.14 | vc4ttpsignallabel | read-only |
The signal label indicates the multiplexing structure of the vc4. If the signal label received for this vc4 is not null and does not match this field, a Signal Label Mismatch failure is detected. If the received label is null a virtual container UNEQuiped failure is detected. |
vc4TTPLabelSent | 1.3.6.1.4.1.1038.110.100.2.1.15 | vc4ttpsignallabel | read-write |
The signal label indicates the multiplexing structure of the vc4. The value of this field in sent as signal label for the vc4. |
vc4TTPLabelReceived | 1.3.6.1.4.1.1038.110.100.2.1.16 | vc4ttpsignallabel | read-only |
The signal label indicates the multiplexing structure of the vc4. The value of this field is the actual received signal label for this vc4 |
vc4TTPSdThreshold | 1.3.6.1.4.1.1038.110.100.2.1.17 | integer | read-write |
A Signal Degrade failure is declared if the error block rate is greater than 1E(-SdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - SdThreshold). |
vc4TTPSesThreshold | 1.3.6.1.4.1.1038.110.100.2.1.18 | integer | read-only |
The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
vc4TTPBidirectionnal | 1.3.6.1.4.1.1038.110.100.2.1.19 | sagemboolean | read-write |
If set to false the equipment does not send Remote Defect Indication. |
vc4TTPRdi | 1.3.6.1.4.1.1038.110.100.2.1.20 | severity | read-write |
Severity associed with Remote Defect Indication failure for virtual container order 4. |
vc4TTPSd | 1.3.6.1.4.1.1038.110.100.2.1.21 | severity | read-write |
Severity associed with Signal Degrade failure for virtual container order 4. |
vc4TTPUneq | 1.3.6.1.4.1.1038.110.100.2.1.22 | severity | read-write |
Severity associed with virtual container UNEQuiped failure for virtual container order 4. |
vc4TTPPlm | 1.3.6.1.4.1.1038.110.100.2.1.23 | severity | read-write |
Severity associed with Path Label Mismatch failure for virtual container order 4. |
vc4TTPTimDis | 1.3.6.1.4.1.1038.110.100.2.1.24 | sagemboolean | read-write |
If set to true the equipment does not manage the Tim Failure. |
vc4TTPTim | 1.3.6.1.4.1.1038.110.100.2.1.25 | severity | read-write |
Severity associed with Trail Identifier Mismatch failure for virtual container order 4. |
tu3CTP | 1.3.6.1.4.1.1038.110.120 | |||
tu3CTPNumber | 1.3.6.1.4.1.1038.110.120.1 | integer | read-only |
Number of tributary unit in equipment. |
tu3CTPTable | 1.3.6.1.4.1.1038.110.120.2 | no-access |
List of tributary units order 3 in equipment which are availables for new connection or used in the same connection level. In that case, an indication on the connection point status is set into the tu3CTPStatus Variable. All tu3 CTP, which are involved in different connection level (tu12 or au4), disappear from this List. |
|
1.3.6.1.4.1.1038.110.120.2.1 | no-access |
A particular tributary unit of the equipment. |
||
tu3CTPIndex | 1.3.6.1.4.1.1038.110.120.2.1.1 | integer | read-only |
Index that identifies the particular entry among the tributary unit entries. |
tu3CTPStatus | 1.3.6.1.4.1.1038.110.120.2.1.2 | ctpstatus | read-only |
tu3 connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP |
tu3CTPName | 1.3.6.1.4.1.1038.110.120.2.1.5 | displaystring | read-write |
A text string which identifies the particular entry among the tributary unit entries. |
tu3CTPMonitor | 1.3.6.1.4.1.1038.110.120.2.1.6 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this tributary unit. |
tu3CTPFailure | 1.3.6.1.4.1.1038.110.120.2.1.7 | tu3ctpfailure | read-only |
Active failures on tributary unit |
tu3CTPSeverity | 1.3.6.1.4.1.1038.110.120.2.1.8 | severity | read-only |
A reference to failure severity for tributary unit. |
tu3CTPAis | 1.3.6.1.4.1.1038.110.120.2.1.20 | severity | read-write |
Severity associed with Alarme Indication Signal failure for tributary unit. |
tu3CTPLop | 1.3.6.1.4.1.1038.110.120.2.1.21 | severity | read-write |
Severity associed with Loss Of Pointer failure for tributary unit. |
vc3TTP | 1.3.6.1.4.1.1038.110.130 | |||
vc3TTPNumber | 1.3.6.1.4.1.1038.110.130.1 | integer | read-only |
Number of virtual container order 3 in equipment. |
vc3TTPTable | 1.3.6.1.4.1.1038.110.130.2 | no-access |
List of virtual container order 3 in equipment.The number of records depends on the kinds of configured boards |
|
1.3.6.1.4.1.1038.110.130.2.1 | no-access |
A particular virtual container order 3 of the equipment. |
||
vc3TTPIndex | 1.3.6.1.4.1.1038.110.130.2.1.1 | integer | read-only |
A unique value which identify a particular virtual container order 3. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
vc3TTPSinkPointer | 1.3.6.1.4.1.1038.110.130.2.1.2 | integer | read-only |
A reference to the object which sends the data flow to this function on non-sdh physical port side. |
vc3TTPSinkType | 1.3.6.1.4.1.1038.110.130.2.1.3 | vc3ttpsinktype | read-only |
A reference to the kind of the sink Pointer |
vc3TTPName | 1.3.6.1.4.1.1038.110.130.2.1.5 | displaystring | read-write |
A text string which identifies the particular entry among the virtual container order 3 entries. |
vc3TTPMonitor | 1.3.6.1.4.1.1038.110.130.2.1.6 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this virtual container order 3. |
vc3TTPFailure | 1.3.6.1.4.1.1038.110.130.2.1.7 | vclofailure | read-only |
Active failures on virtual container order 3 |
vc3TTPSeverity | 1.3.6.1.4.1.1038.110.130.2.1.8 | severity | read-only |
A reference to failure severity for virtual container order 3. |
vc3TTPPathTraceExpected | 1.3.6.1.4.1.1038.110.130.2.1.9 | octet string | read-write |
The path trace is a user string that always follows the vc3. If the value the received path trace does not match this one, a tim (Trail Identifier Mismatch) failure is issued. The value `? ' match all possible received path trace. |
vc3TTPPathTraceSent | 1.3.6.1.4.1.1038.110.130.2.1.10 | octet string | read-write |
The path trace is a user string that always follows the vc3. The value of this field is sent in j1 byte as path trace for this vc3. The default value is `all 0'. |
vc3TTPPathTraceReceived | 1.3.6.1.4.1.1038.110.130.2.1.11 | octet string | read-only |
The path trace is a user string that always follows the vc3. The value is the actual path trace received in j1 byte |
vc3TTPLabelExpected | 1.3.6.1.4.1.1038.110.130.2.1.12 | vc3ttpsignallabel | read-only |
The signal label indicates the multiplexing structure of the vc3. Usualy the value of this field cannot be modified as most equipment use the asynchronous bit multiplexing. For historical reasons the receipt of label `unspecified ' does not produce a Signal Label Mismatch failure. |
vc3TTPLabelSent | 1.3.6.1.4.1.1038.110.130.2.1.13 | vc3ttpsignallabel | read-write |
The signal label indicates the multiplexing structure of the vc3. The value of this field is sent as signal label for the vc3. The unspecified value is used for compatibilty with old sdh equipments. The `unequiped' value actives low order unequiped generator (lug). In this case all 1 signal is inserted down and up stream. |
vc3TTPLabelReceived | 1.3.6.1.4.1.1038.110.130.2.1.14 | vc3ttpsignallabel | read-only |
The signal label indicates the multiplexing structure of the vc3. The value of this field is the actual received signal label for this vc3 |
vc3TTPSdThreshold | 1.3.6.1.4.1.1038.110.130.2.1.15 | integer | read-write |
A Signal Degrade failure is declared if the error block rate is greater than 1E(-SdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - SdThreshold). |
vc3TTPSesThreshold | 1.3.6.1.4.1.1038.110.130.2.1.16 | integer | read-only |
The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
vc3TTPBidirectionnal | 1.3.6.1.4.1.1038.110.130.2.1.17 | sagemboolean | read-write |
If set to false the equipment does not send Remote Defect Indication. |
vc3TTPRdi | 1.3.6.1.4.1.1038.110.130.2.1.20 | severity | read-write |
Severity associed with Remote Defect Indication failure for virtual container order 3. |
vc3TTPSd | 1.3.6.1.4.1.1038.110.130.2.1.21 | severity | read-write |
Severity associed with Signal Degrade failure for virtual container order 3. |
vc3TTPUneq | 1.3.6.1.4.1.1038.110.130.2.1.22 | severity | read-write |
Severity associed with virtual container UNEQuiped failure for virtual container order 3. |
vc3TTPPlm | 1.3.6.1.4.1.1038.110.130.2.1.23 | severity | read-write |
Severity associed with Path Label Mismatch failure for virtual container order 3. |
vc3TTPTim | 1.3.6.1.4.1.1038.110.130.2.1.24 | severity | read-write |
Severity associed with Trail Identifier Mismatch failure for virtual container order 3. |
tu12CTP | 1.3.6.1.4.1.1038.110.140 | |||
tu12CTPNumber | 1.3.6.1.4.1.1038.110.140.1 | integer | read-only |
Number of tributary unit in equipment. |
tu12CTPTable | 1.3.6.1.4.1.1038.110.140.2 | no-access |
List of tributary unit order 12 in equipment which are availables for new connection or used in the same connection level. In that case, an indication on the connection point Status is set into the tu12CTPStatus Variable. All tu12 CTP, which are involved in a different connection level (tu3 or au4), disappear from this List. |
|
1.3.6.1.4.1.1038.110.140.2.1 | no-access |
A particular tributary unit of the equipment. |
||
tu12CTPIndex | 1.3.6.1.4.1.1038.110.140.2.1.1 | integer | read-only |
A unique value which identify a particular tu12. |
tu12CTPStatus | 1.3.6.1.4.1.1038.110.140.2.1.2 | ctpstatus | read-only |
tu12 connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP |
tu12CTPName | 1.3.6.1.4.1.1038.110.140.2.1.5 | displaystring | read-write |
A text string which identifies the particular entry among the tributary unit entries. |
tu12CTPMonitor | 1.3.6.1.4.1.1038.110.140.2.1.6 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this tributary unit. |
tu12CTPFailure | 1.3.6.1.4.1.1038.110.140.2.1.7 | tu12ctpfailure | read-only |
Active failures on tributary unit |
tu12CTPSeverity | 1.3.6.1.4.1.1038.110.140.2.1.8 | severity | read-only |
A reference to failure severity for tributary unit. |
tu12CTPAis | 1.3.6.1.4.1.1038.110.140.2.1.20 | severity | read-write |
Severity associed with Alarme Indication Signal failure for tributary unit. |
tu12CTPLop | 1.3.6.1.4.1.1038.110.140.2.1.21 | severity | read-write |
Severity associed with Loss Of Pointer failure for tributary unit. |
vc12TTP | 1.3.6.1.4.1.1038.110.150 | |||
vc12TTPNumber | 1.3.6.1.4.1.1038.110.150.1 | integer | read-only |
Number of virtual container order 12 in equipment. |
vc12TTPTable | 1.3.6.1.4.1.1038.110.150.2 | no-access |
List of virtual container order 12 in equipment.The number of records depends on the kinds of configured boards |
|
1.3.6.1.4.1.1038.110.150.2.1 | no-access |
A particular virtual container order 12 of the equipment. |
||
vc12TTPIndex | 1.3.6.1.4.1.1038.110.150.2.1.1 | integer | read-only |
A unique value which identify a particular virtual container order 12. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
vc12TTPSinkPointer | 1.3.6.1.4.1.1038.110.150.2.1.2 | integer | read-only |
A reference to the object which sends the data flow to this function on non-sdh physical port side. |
vc12TTPSinkType | 1.3.6.1.4.1.1038.110.150.2.1.3 | vc12ttpsinktype | read-only |
A reference to the kind of the sink Pointer |
vc12TTPName | 1.3.6.1.4.1.1038.110.150.2.1.5 | displaystring | read-write |
A text string which identifies the particular entry among the virtual container order 12 entries. |
vc12TTPMonitor | 1.3.6.1.4.1.1038.110.150.2.1.6 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this virtual container order 12. |
vc12TTPFailure | 1.3.6.1.4.1.1038.110.150.2.1.7 | vclofailure | read-only |
Active failures on virtual container order 12 |
vc12TTPSeverity | 1.3.6.1.4.1.1038.110.150.2.1.8 | severity | read-only |
A reference to failure severity for virtual container order 12. |
vc12TTPPathTraceExpected | 1.3.6.1.4.1.1038.110.150.2.1.9 | octet string | read-write |
The path trace is a user string that always follows the vc12. If the value the received path trace does not match this one, a tim (Trail Identifier Mismatch) failure is issued. The value `? ' match all possible received path trace. |
vc12TTPPathTraceSent | 1.3.6.1.4.1.1038.110.150.2.1.10 | octet string | read-write |
The path trace is a user string that always follows the vc12. The value of this field is sent in j2 byte as path trace for this vc12. The default value is `all 0'. |
vc12TTPPathTraceReceived | 1.3.6.1.4.1.1038.110.150.2.1.11 | octet string | read-only |
The path trace is a user string that always follows the vc12. The value is the actual path trace received in j2 byte |
vc12TTPLabelExpected | 1.3.6.1.4.1.1038.110.150.2.1.12 | vc12ttpsignallabel | read-only |
The signal label indicates the multiplexing structure of the vc12. Usualy the value of this field cannot be modified as most equipment use the asynchronous bit multiplexing. For historical reasons the receipt of label `unspecified ' does not produce a Signal Label Mismatch failure. |
vc12TTPLabelSent | 1.3.6.1.4.1.1038.110.150.2.1.13 | vc12ttpsignallabel | read-write |
The signal label indicates the multiplexing structure of the vc12. The value of this field is sent as signal label for the vc12. The unspecified value is used for compatibilty with old sdh equipments. The `unequiped' value actives low order unequiped generator (lug). In this case all 1 signal is inserted down and up stream. |
vc12TTPLabelReceived | 1.3.6.1.4.1.1038.110.150.2.1.14 | vc12ttpsignallabel | read-only |
The signal label indicates the multiplexing structure of the vc12. The value of this field is the actual received signal label for this vc12 |
vc12TTPSdThreshold | 1.3.6.1.4.1.1038.110.150.2.1.15 | integer | read-write |
A Signal Degrade failure is declared if the error block rate is greater than 1E(-SdThreshold). The Signal Degrade failure desapeared when the error block rate is less than 1E(1 - SdThreshold). |
vc12TTPSesThreshold | 1.3.6.1.4.1.1038.110.150.2.1.16 | integer | read-only |
The number of errors above which the second is declared severely errored for this interface/function. This value apply for near and far interface/function |
vc12TTPBidirectionnal | 1.3.6.1.4.1.1038.110.150.2.1.17 | sagemboolean | read-write |
If set to false the equipment does not send Remote Defect Indication. |
vc12TTPRdi | 1.3.6.1.4.1.1038.110.150.2.1.20 | severity | read-write |
Severity associed with Remote Defect Indication failure for virtual container order 12. |
vc12TTPSd | 1.3.6.1.4.1.1038.110.150.2.1.21 | severity | read-write |
Severity associed with Signal Degrade failure for virtual container order 12. |
vc12TTPUneq | 1.3.6.1.4.1.1038.110.150.2.1.22 | severity | read-write |
Severity associed with virtual container UNEQuiped failure for virtual container order 12. |
vc12TTPPlm | 1.3.6.1.4.1.1038.110.150.2.1.23 | severity | read-write |
Severity associed with Path Label Mismatch failure for virtual container order 12. |
vc12TTPTim | 1.3.6.1.4.1.1038.110.150.2.1.24 | severity | read-write |
Severity associed with Trail Identifier Mismatch failure for virtual container order 12. |
nspiCTP | 1.3.6.1.4.1.1038.110.160 | |||
nspiCTPNumber | 1.3.6.1.4.1.1038.110.160.1 | integer | read-only |
A unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
nspiCTPTable | 1.3.6.1.4.1.1038.110.160.2 | no-access |
List of non-sdh physical port in equipment. |
|
1.3.6.1.4.1.1038.110.160.2.1 | no-access |
A particular non-sdh physical port of the equipment. |
||
nspiCTPIndex | 1.3.6.1.4.1.1038.110.160.2.1.1 | integer | read-only |
A unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
nspiCTPTTPType | 1.3.6.1.4.1.1038.110.160.2.1.2 | nspisrctype | read-only |
The type of VC which is associated to the nspi interface. |
nspiCTPStatus | 1.3.6.1.4.1.1038.110.160.2.1.3 | ctpstatus | read-only |
nspi connection point Status: free or used. The 'free' value is used when there is no connection with this output CTP |
nspiCTPName | 1.3.6.1.4.1.1038.110.160.2.1.4 | displaystring | read-write |
A text string which identifies the particular entry among the non-sdh physical port entries. |
nspiTTP | 1.3.6.1.4.1.1038.110.170 | |||
nspiTTPNumber | 1.3.6.1.4.1.1038.110.170.1 | integer | read-only |
A unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
nspiTTPTable | 1.3.6.1.4.1.1038.110.170.2 | no-access |
List of non-sdh physical port in equipment. |
|
1.3.6.1.4.1.1038.110.170.2.1 | no-access |
A particular non-sdh physical port of the equipment. |
||
nspiTTPIndex | 1.3.6.1.4.1.1038.110.170.2.1.1 | integer | read-only |
A unique value which identify a particular non-sdh physical port. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
nspiTTPType | 1.3.6.1.4.1.1038.110.170.2.1.2 | nspittptype | read-only |
The type of media for the nspi interface. |
nspiTTPLevel | 1.3.6.1.4.1.1038.110.170.2.1.3 | nspittplevel | read-only |
The rate level of the nspi interface. |
nspiTTPName | 1.3.6.1.4.1.1038.110.170.2.1.4 | displaystring | read-write |
A text string which identifies the particular entry among the non-sdh physical port entries. |
nspiTTPBoardIndex | 1.3.6.1.4.1.1038.110.170.2.1.5 | integer | read-only |
Index of the Board that supports the physical acces of this interface |
nspiTTPBoardAcces | 1.3.6.1.4.1.1038.110.170.2.1.6 | integer | read-only |
Friendly Index of the physical acces on the Board that supports the interface |
nspiTTPSrcType | 1.3.6.1.4.1.1038.110.170.2.1.7 | nspisrctype | read-only |
A reference to the type of object which sends the data flow to this interface. Usually the value is vc12, vc3 or vc4 types. |
nspiTTPSrcPointer | 1.3.6.1.4.1.1038.110.170.2.1.8 | integer | read-only |
A reference to the object which sends the data flow to this interface. Usually the value is the Index of a vc12, vc3 or vc4. |
nspiTTPMonitor | 1.3.6.1.4.1.1038.110.170.2.1.9 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this non-sdh physical port. |
nspiTTPFailure | 1.3.6.1.4.1.1038.110.170.2.1.10 | nspittpfailure | read-only |
Active failures on non-sdh physical port |
nspiTTPSeverity | 1.3.6.1.4.1.1038.110.170.2.1.11 | severity | read-only |
A reference to failure severity for non-sdh physical port. |
nspiTTPLoopback | 1.3.6.1.4.1.1038.110.170.2.1.14 | loopback | read-write |
This field gives the active loopback status on the non-sdh physical port. When its value is `line' the data flow recieved from the port side is sent back to the line. When its value is `equipment' the data flow recieved form equipment side is send back. The field can be set to a particular loopback value, even if there no garantee that the loopback is really done. The real loopback status of the interface must be checked in the response. The loopback can be cleared by the equipment when it cannot remain for any reason. |
nspiTTPLos | 1.3.6.1.4.1.1038.110.170.2.1.20 | severity | read-write |
Severity associed with Loss Of Signal failure for non-sdh physical port. |
nspiTTPAis | 1.3.6.1.4.1.1038.110.170.2.1.21 | severity | read-write |
Severity associed with Alarme Indication Signal failure for non-sdh physical port. |
channel | 1.3.6.1.4.1.1038.110.180 | |||
channelNumber | 1.3.6.1.4.1.1038.110.180.1 | integer | read-only |
Number of SDH Channels in equipment. |
channelTable | 1.3.6.1.4.1.1038.110.180.2 | no-access |
List of SDH Channels in equipment. |
|
1.3.6.1.4.1.1038.110.180.2.1 | no-access |
A particular SDH Channel of the equipment. |
||
channelIndex | 1.3.6.1.4.1.1038.110.180.2.1.1 | integer | read-only |
A unique value which identify a particular SDH Channel. The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. |
channelEncaps | 1.3.6.1.4.1.1038.110.180.2.1.2 | channelencaps | read-write |
The type of encapsulation used to map Data stream into Sdh containers |
channelNbVc4 | 1.3.6.1.4.1.1038.110.180.2.1.5 | integer | read-write |
Number of VC4 into the channel. |
channelNbVc3 | 1.3.6.1.4.1.1038.110.180.2.1.6 | integer | read-write |
Number of VC3 into the channel. |
channelNbVc12 | 1.3.6.1.4.1.1038.110.180.2.1.7 | integer | read-write |
Number of VC12 into the channel. |
channelConcat | 1.3.6.1.4.1.1038.110.180.2.1.8 | channelconcat | read-write |
The type of Concatenation used within the channel |
channelAdminStatus | 1.3.6.1.4.1.1038.110.180.2.1.9 | integer | read-write |
The desired state of the channel. The testing(3) state indicates that no operational packets can be passed. Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
channelOperStatus | 1.3.6.1.4.1.1038.110.180.2.1.10 | integer | read-only |
The current operational state of the channel. The testing(3) state indicates that no operational packets can be passed. Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
channelFirstIndex | 1.3.6.1.4.1.1038.110.180.2.1.11 | integer | read-write |
Index of the first Vc in the Channel when it is configured. Otherwise this field is set to 0. |
channelDelay | 1.3.6.1.4.1.1038.110.180.2.1.12 | integer | read-write |
This field give the maximum delay (in millisecondes) for receiving virtual concatenated frames. This field is set to 0 when channelConcat is different to virtual(1) |
channelMonitor | 1.3.6.1.4.1.1038.110.180.2.1.13 | sagemboolean | read-write |
When the value of this field is set to false, the failure detection is stopped for this channel. |
channelFailure | 1.3.6.1.4.1.1038.110.180.2.1.14 | channelfailure | read-only |
Active failures on channel |
channelSeverity | 1.3.6.1.4.1.1038.110.180.2.1.15 | severity | read-only |
A reference to failure severity for non-sdh physical port. |
channelLoa | 1.3.6.1.4.1.1038.110.180.2.1.16 | severity | read-write |
Severity associated with Loss Of Alignment failure for channel. |
channelLom | 1.3.6.1.4.1.1038.110.180.2.1.17 | severity | read-write |
Severity associated with Loss Of Multiframe failure for channel. |
channelSqm | 1.3.6.1.4.1.1038.110.180.2.1.18 | severity | read-write |
Severity associated with Sequence Mismatch failure for channel. |
bandwidth | 1.3.6.1.4.1.1038.110.190 | |||
bandwidthNumber | 1.3.6.1.4.1.1038.110.190.1 | integer | read-only |
Number of bandwidth units which are available in the equipement. The number of units depends on their type (Vc4, Vc3, Vc12), on the number of Data card and on the bandwidth size which has been configured for this card. For a Data card which is mapped on a STM16, there are 16 Vc4 entries (or 3*16 Vc3 entries or 63*16 Vc12 entries) in the BandwidthTable. |
bandwidthTable | 1.3.6.1.4.1.1038.110.190.2 | no-access |
List of Bandwidth units in equipment. It represent the bandwidth occupation of each non-sdh card |
|
1.3.6.1.4.1.1038.110.190.2.1 | no-access |
A particular unit part of a non-sdh card bandwidth. |
||
bandwidthIndex | 1.3.6.1.4.1.1038.110.190.2.1.1 | integer | read-only |
A unique value which identify a particular unit of a non-sdh card bandwidth. The value of index is a Vc Index which change when bandwidthSrcType value is modified. |
bandwidthBoardIndex | 1.3.6.1.4.1.1038.110.190.2.1.2 | integer | read-only |
Index of the Board that supports the bandwidth unit. |
bandwidthSrcType | 1.3.6.1.4.1.1038.110.190.2.1.3 | nspisrctype | read-write |
Define the decomposition level of the bandwidth. |
bandwidthSrcPointer | 1.3.6.1.4.1.1038.110.190.2.1.4 | integer | read-only |
this field is set to bandwidthIndex when the unit is used by a channel and set to 0 otherwise. It defines the TTP and CTP index associated to the channel. |
bandwidthSinkType | 1.3.6.1.4.1.1038.110.190.2.1.5 | nspisrctype | read-write |
A reference to the kind of the sink Pointer. Usually the value is Channel. |
bandwidthSinkPointer | 1.3.6.1.4.1.1038.110.190.2.1.6 | integer | read-write |
A reference to the object which sends the data flow to this function on unsynchronous port interface side. This pointer corresponds to an index in the channelTable. |
bandwidthAdminStatus | 1.3.6.1.4.1.1038.110.190.2.1.7 | integer | read-write |
The desired state of the Vc. The testing(3) state indicates that no operational packets can be passed. Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
bandwidthOperStatus | 1.3.6.1.4.1.1038.110.190.2.1.8 | integer | read-only |
The current operational state of the Vc. The testing(3) state indicates that no operational packets can be passed. Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
bandwidthPrevIndex | 1.3.6.1.4.1.1038.110.190.2.1.9 | integer | read-only |
A reference to the previous VC into the channel. This field is set to 0 if the VC is not associated to a channel or if it is the first Vc of the channel. |
bandwidthNextIndex | 1.3.6.1.4.1.1038.110.190.2.1.10 | integer | read-only |
A reference to the next VC into the channel. This field is set to 0 if the VC is not associated to a channel or if it is the last Vc of the channel. |