PROTECTION-MIB: View SNMP OID List / Download MIB

VENDOR: SAGEMCOM SAS


 Home MIB: PROTECTION-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 protection 1.3.6.1.4.1.1038.130
This MIB describe protection mechanisms used by SDH equipment
         msp 1.3.6.1.4.1.1038.130.10
               mspNumber 1.3.6.1.4.1.1038.130.10.1 integer read-only
Number of multiplex section protection in equipment.
               mspTable 1.3.6.1.4.1.1038.130.10.2 no-access
List of multiplex section protection in equipment.
                   mspEntry 1.3.6.1.4.1.1038.130.10.2.1 no-access
A particular multiplex section protection of the equipment. Each entry is created in using the msTTPTable of the Sdh-Ets MIB.
                       mspIndex 1.3.6.1.4.1.1038.130.10.2.1.1 integer read-only
A unique value which identify a particular multiplex section protection. This index is equal to an msTTPIndex(=spiIndex) which gives the interface involved . The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware.
                       mspWorkingPointer 1.3.6.1.4.1.1038.130.10.2.1.2 integer read-only
A reference to the object which sends the data flow to this function on working synchronous port interface side. In most equipments, this value cannot be changed and points to the working MST it is hard wired with.
                       mspProtectionPointer 1.3.6.1.4.1.1038.130.10.2.1.3 integer read-write
A reference to the object which sends the data flow to this function on protection synchronous port interface side. In most equipments, this value cannot be changed and points to the protection MST it is hard wired with. When this variable is setting, the protection is created and activated (if it's possible). The two considerated sections must have the same Stm Level.
                       mspType 1.3.6.1.4.1.1038.130.10.2.1.4 msptype read-write
Indication of the protection type.
                       mspDir 1.3.6.1.4.1.1038.130.10.2.1.5 mspdirection read-write
Indication of the direction.
                       mspTraffic 1.3.6.1.4.1.1038.130.10.2.1.6 trafficstatus read-only
The value of this field indicates the protection switch position.
                       mspRevertive 1.3.6.1.4.1.1038.130.10.2.1.7 sagemboolean read-write
If the value is true the msp function is allowed to spontaneously switch back to working chanel when it is available. If not, the msp can switch back to working chanel only if protection chanel fails.
                       mspWtr 1.3.6.1.4.1.1038.130.10.2.1.8 integer read-write
The time (in seconds) the msp function waits before considering a chanel as good after a fail.
                       mspSfSdPriority 1.3.6.1.4.1.1038.130.10.2.1.9 msppriority read-write
Signal Fail and Signal Degrade can be treated according to two set of priority. The equipement will send SF and SD events according to the value of this field.
                       mspSfSdHoldOffTime 1.3.6.1.4.1.1038.130.10.2.1.10 integer read-write
The period (in tenth of seconds) during which a sf or a Signal Degrade is ignored by the MSP switch.
                       mspCommand 1.3.6.1.4.1.1038.130.10.2.1.11 mspcommand read-write
Manual or forced commands can be apply to the protection switch. The forced and manual switch can be refused or cleared by equipment if a higher priority APS command is received or if the protection chanel is down. When this field is set to manual or forced, the mspTraffic field becomes read-write, and a set can be issued to specifie on which chanel the command does apply. Commands: LP (Lockout of Protection) LW (Lockout of Working channel) FSW (Forced Switch of a Working channel to protection) FSP (Forced Switch of a Protection channel to working) case 1+1 MSW (Manual Switch of a Working channel to protection) MSp (Manual Switch of a Protection channel to working) case 1+1 EXER (EXERcise)
                       mspInitiator 1.3.6.1.4.1.1038.130.10.2.1.12 mspinitiator read-only
Indicates the initiator equipment.
                       mspStatus 1.3.6.1.4.1.1038.130.10.2.1.13 mspstatus read-only
Indicates the initiator equipment status : lockoutProtection(15), forcedSwitch(14), highSF(13), lowSF(12), highSD(11), lowSD(10), manualSwitch(8), waitToRestore(6), exercise(4), reverseRequest(2), doNotRevert(1), noRequest(0)
                       mspMonitor 1.3.6.1.4.1.1038.130.10.2.1.14 sagemboolean read-write
When the value of this field is set to false, the failure detection is stopped for this multiplex section protection.
                       mspFailure 1.3.6.1.4.1.1038.130.10.2.1.15 mspfailure read-only
Active failures on multiplex section protection.
                       mspSeverity 1.3.6.1.4.1.1038.130.10.2.1.16 severity read-only
A reference to failure severity for multiplex section protection.
                       mspPam 1.3.6.1.4.1.1038.130.10.2.1.20 severity read-write
Severity associed with Protection Architecture Mismatch failure for multiplex section protection.
                       mspScm 1.3.6.1.4.1.1038.130.10.2.1.21 severity read-write
Severity associed with Selector Control Mismatch failure for multiplex section protection.
                       mspOtm 1.3.6.1.4.1.1038.130.10.2.1.22 severity read-write
Severity associed with Operation Type Mismatch failure for multiplex section protection.
         msSPRing 1.3.6.1.4.1.1038.130.20
               msSPRingNumber 1.3.6.1.4.1.1038.130.20.1 integer read-only
Number of multiplex section protection in equipment.
               msSPRingTable 1.3.6.1.4.1.1038.130.20.6 no-access
List of multiplex section protection in equipment.
                   msSPRingEntry 1.3.6.1.4.1.1038.130.20.6.1 no-access
A particular multiplex section protection of the equipment. Each entry is created in using the msTTPTable of the Sdh-Ets MIB. spiIndex gives the interface involved (line east or west)
                       msSPRingIndex 1.3.6.1.4.1.1038.130.20.6.1.1 integer read-only
A unique value which identify a particular SPRing = West STM index.
                       msSPRingWestPointer 1.3.6.1.4.1.1038.130.20.6.1.2 integer read-only
A reference to the object which sends the data flow to this function on synchronous port interface side. In most equipments, this value cannot be changed and points to the West MST it is hard wired with.
                       msSPRingEastPointer 1.3.6.1.4.1.1038.130.20.6.1.3 integer read-write
A reference to the object which sends the data flow to this function on synchronous port interface side. In most equipments, this value cannot be changed and points to the East MST it is hard wired with. When this variable is setting, the protection is created and activated (if it's possible). The two considerated sections must have the same Stm Level.
                       msSPRingWtr 1.3.6.1.4.1.1038.130.20.6.1.5 integer read-write
The time (in seconds) the spring function waits before considering a chanel as good after a fail.
                       msSPRingSfSdHoldOffTime 1.3.6.1.4.1.1038.130.20.6.1.6 integer read-write
The period (in tenth of seconds) during which a sf or a Signal Degrade is ignored by the SPRing switch.
                       msSPRingCommandSide 1.3.6.1.4.1.1038.130.20.6.1.7 integer read-write
Side of the command
                       msSPRingCommand 1.3.6.1.4.1.1038.130.20.6.1.8 msspringcommand read-write
Manual or forced commands can be apply to the protection switch.
                       msSPRingInitiator1 1.3.6.1.4.1.1038.130.20.6.1.10 msspringid read-only
A reference(ID) to the equipment that initiate the SWITCH; this is mainly the Master when the equipment is in SWITCH state; in some case like bidirectional SF both equipment of the couple equipment are Master. In PASS state Master and Slave are undeterminated
                       msSPRingInitiator2 1.3.6.1.4.1.1038.130.20.6.1.11 msspringid read-only
A reference(ID) to the equipment that respond to the SWITCH; this is mainly the Slave when the equipment is in SWITCH state; in some case like bidirectional SF both equipment of the couple equipment are Master. In PASS state Master and Slave are undeterminated
                       msSPRingMonitor 1.3.6.1.4.1.1038.130.20.6.1.12 sagemboolean read-write
When the value of this field is set to false, the failure detection is stopped for this multiplex section protection.
                       msSPRingFailure 1.3.6.1.4.1.1038.130.20.6.1.13 msspringfailure read-only
Active failures on multiplex section protection
                       msSPRingSeverity 1.3.6.1.4.1.1038.130.20.6.1.14 severity read-only
A reference to failure severity for multiplex section protection.
                       msSPRingAto 1.3.6.1.4.1.1038.130.20.6.1.21 severity read-write
Severity associed with APS Time Out failure failure for MS-SPRing.
                       msSPRingArv 1.3.6.1.4.1.1038.130.20.6.1.22 severity read-write
Severity associed with APS Rules Violation failure failure for MS-SPRing.
                       msSPRingAun 1.3.6.1.4.1.1038.130.20.6.1.23 severity read-write
Severity associed with APS Unknown Node failure failure for MS-SPRing.
                       msSPRingPtm 1.3.6.1.4.1.1038.130.20.6.1.24 severity read-write
Severity associed with Potential Traffic Misconnection failure for MS-SPRing.
                       msSPRingMms 1.3.6.1.4.1.1038.130.20.6.1.25 severity read-write
Severity associed with Mutiple Multiplex Section Fail failure for MS-SPRing.
                       msSPRingExr 1.3.6.1.4.1.1038.130.20.6.1.26 severity read-write
Severity associed with EXeRcise failure for MS-SPRing.
                       msSPRingSimpleFailure 1.3.6.1.4.1.1038.130.20.6.1.27 sagemboolean read-write
Indicate if simple or multi ring failure must be considerated
                       msSPRingId 1.3.6.1.4.1.1038.130.20.6.1.28 msspringid read-write
Ring Identifier of the equipement
                       msSPRingNodeState 1.3.6.1.4.1.1038.130.20.6.1.29 state read-only
                       msSPRingSwitchingSide 1.3.6.1.4.1.1038.130.20.6.1.30 integer read-only
Switching SideSide
                       msSPRingWestTraffic 1.3.6.1.4.1.1038.130.20.6.1.31 trafficstatus read-only
The value of this field indicates the protection switch position.
                       msSPRingEastTraffic 1.3.6.1.4.1.1038.130.20.6.1.32 trafficstatus read-only
The value of this field indicates the protection switch position.
                       msSPRingWestStatus 1.3.6.1.4.1.1038.130.20.6.1.33 msspringstatus read-only
Indicates the local status: OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8), manualSwitch-R(6), waitToRestore(5),exer-R(3),noRequest(0)
                       msSPRingEastStatus 1.3.6.1.4.1.1038.130.20.6.1.34 msspringstatus read-only
Indicates the local status: OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8), manualSwitch-R(6), waitToRestore(5),exer-R(3),noRequest(0)
               msSPRingTopoMapTable 1.3.6.1.4.1.1038.130.20.11 no-access
Topology Map of the ring = West STM index + Val (1<=Val<=16).
                     msSPRingTopoMapEntry 1.3.6.1.4.1.1038.130.20.11.1 no-access
A particular entry of the ring topology map.
                         msSPRingTopoMapIndex 1.3.6.1.4.1.1038.130.20.11.1.1 integer read-only
index
                         msSPRingTopoMapID 1.3.6.1.4.1.1038.130.20.11.1.2 msspringid read-write
identifier of the node
               msSPRingMisconMapTable 1.3.6.1.4.1.1038.130.20.21 no-access
Connectivity (misconnection) Map of the ring.
                     msSPRingMisconMapEntry 1.3.6.1.4.1.1038.130.20.21.1 no-access
A particular entry of the ring connectivity (misconnection) map. All entries are created after setting the msSPRingWestPointer.
                         msSPRingMisconMapIndex 1.3.6.1.4.1.1038.130.20.21.1.1 integer read-only
Index = West STM index + Val (1<=Val<=16) ADR2500c : val = 1 to 8 for West and 9 to 16 for East
                         msSPRingMisconMapSide 1.3.6.1.4.1.1038.130.20.21.1.2 msspringside read-only
Side (WestPointer/msSPRingEast) of the interface that supports the AU4
                         msSPRingMisconMapIn 1.3.6.1.4.1.1038.130.20.21.1.3 msspringid read-write
Node of the ring where the Au4 traffic enters the ring
                         msSPRingMisconMapOut 1.3.6.1.4.1.1038.130.20.21.1.4 msspringid read-write
Node of the ring where the Au4 traffic exits the ring
                         msSPRingMisconMapTimeSlot 1.3.6.1.4.1.1038.130.20.21.1.5 integer read-write
Time Slot assignment for the AU4
                         msSPRingMisconMapType 1.3.6.1.4.1.1038.130.20.21.1.6 misconmaptype read-write
If the value is equal to terminated, the traffic in the ring is inserted or extracted at this node. If the value is equal to passedThrough the traffic only cross the node
                         msSPRingMisconMapLOAccess 1.3.6.1.4.1.1038.130.20.21.1.7 sagemboolean read-write
True if the AU4 is accessed at LO layers somewhere in the ring
               msSPRingNUTTable 1.3.6.1.4.1.1038.130.20.31 no-access
Topology Map of the ring.
                     msSPRingNUTEntry 1.3.6.1.4.1.1038.130.20.31.1 no-access
A particular entry of the ring topology map.
                         msSPRingNUTIndex 1.3.6.1.4.1.1038.130.20.31.1.1 integer read-only
AU4 index = West STM index + Val (Val = working timeSlot; 1<=Val<=8)
                         msSPRingNUTisNut 1.3.6.1.4.1.1038.130.20.31.1.2 sagemboolean read-write
Define if the traffic is used for NUT Traffic
         sncp 1.3.6.1.4.1.1038.130.30
               sncNumber 1.3.6.1.4.1.1038.130.30.1 integer read-only
Number of snc in equipment.
               sncTable 1.3.6.1.4.1.1038.130.30.2 no-access
List of snc protection in equipment.
                   sncEntry 1.3.6.1.4.1.1038.130.30.2.1 no-access
A particular SNC protection which is created in using the linkTable of the Xconnection MIB.
                       sncIndex 1.3.6.1.4.1.1038.130.30.2.1.1 integer read-only
sncIndex = 1000*sncType + sncTTPSink = linkIndex
                       sncCTPSink 1.3.6.1.4.1.1038.130.30.2.1.2 integer read-only
The value of this field is the index of the Output Connection to which an snc function is applied.
                       sncLinkType 1.3.6.1.4.1.1038.130.30.2.1.3 linktype read-only
Trail level of the connection
                       sncCTPSourceW 1.3.6.1.4.1.1038.130.30.2.1.4 integer read-only
The value of this field indicates the Working Input Connection Point which composes the protection link of the Output Connection Point (sncIndex).
                       sncCTPSourceP 1.3.6.1.4.1.1038.130.30.2.1.5 integer read-write
The value of this field indicates the Protected Input Connection Point which composes the protection link of the Output Connection Point (sncIndex). When this variable is setting, the protection is created and activated (if it's possible).
                       sncTrafficStatus 1.3.6.1.4.1.1038.130.30.2.1.6 trafficstatus read-only
This field indicates the Protection unit switch position.
                       sncWorkingTriggerType 1.3.6.1.4.1.1038.130.30.2.1.8 triggercriterion read-write
The value of this field is the criterion to trigger a switch for the Working Input Connection Point.SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 , AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs. SNC/N uses also SD criterion for switching: SD-V5 for VC12, SD-B3 for VC3/VC4. SNC+LAN adds MS-RDI as switching criterion for LAN connection. NONE means that just board extractions and some board failures activate switching.
                       sncProtectionTriggerType 1.3.6.1.4.1.1038.130.30.2.1.9 triggercriterion read-write
The value of this field is the criterion to trigger a switch for the Protection Input Connection Point. SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 , AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs. SNC/N uses also SD criterion for switching: SD-V5 for VC12, SD-B3 for VC3/VC4. SNC+LAN adds MS-RDI as switching criterion for LAN connection. NONE means that just board extractions and some board failures activate switching.
                       sncRevertive 1.3.6.1.4.1.1038.130.30.2.1.20 sagemboolean read-write
If the value is true the Protection unit function is allowed to spontaneously switch back to working chanel when it is available. If not, the snc can switch back to working chanel only if protection chanel fails.
                       sncWtr 1.3.6.1.4.1.1038.130.30.2.1.21 integer read-write
The time (in seconds) the Protection unit function waits before considering a chanel as good after a fail.
                       sncStateProcess 1.3.6.1.4.1.1038.130.30.2.1.22 sncstateprocess read-only
The value of this field indicates the state of the snc protection process.
                       sncHoldOffTime 1.3.6.1.4.1.1038.130.30.2.1.23 integer read-write
The time in tenth of seconds during which a protection trigger criterion is ignored.
                       sncCommand 1.3.6.1.4.1.1038.130.30.2.1.24 snccommand read-write
Manual or forced commands can be apply to the protection unit. The forced and manual switch can be refused or cleared by equipment if a higher priority evenement is received or if the protection chanel is down.
         cardp 1.3.6.1.4.1.1038.130.40
               cardpNumber 1.3.6.1.4.1.1038.130.40.1 integer read-only
Number of card protections in equipment.
               cardpTable 1.3.6.1.4.1.1038.130.40.2 no-access
List of card protections in equipment.
                   cardpEntry 1.3.6.1.4.1.1038.130.40.2.1 no-access
A particular card protection which is created in using the boardTable of the Shelf MIB.
                       cardpIndex 1.3.6.1.4.1.1038.130.40.2.1.1 integer read-only
cardpIndex = boardIndex in the Shelf Mib. This index points to the working board.
                       cardpBoardFamily 1.3.6.1.4.1.1038.130.40.2.1.2 cardpfamily read-only
This field indicates the family of board concerned by the protection.
                       cardpReliefIndex 1.3.6.1.4.1.1038.130.40.2.1.3 integer read-write
A reference to the relief card. It must be an existing index in the boardTable of Shelf Mib. The relief card and the protected Card must below to the same familly. When this variable is setting, the protection is created and activated (if it's possible).
                       cardpTrafficStatus 1.3.6.1.4.1.1038.130.40.2.1.4 trafficstatus read-only
Indication of the protection switch position.
                       cardpCommand 1.3.6.1.4.1.1038.130.40.2.1.5 cardpcommand read-write
Manual commands can be apply to the protection unit. The manual switch can be refused or cleared by equipment if a higher priority evenement is received or if the protection chanel is down.
                       cardpStatus 1.3.6.1.4.1.1038.130.40.2.1.6 cardpstatus read-only
Indication of the current protection status