OMNI-gx2litePS-MIB: View SNMP OID List / Download MIB
VENDOR: GENERAL INSTRUMENT
Home | MIB: OMNI-gx2litePS-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
gx2LitepsDescriptor | 1.3.6.1.4.1.1166.6.1.2.23.1 | |||
gx2LitepsAnalogTable | 1.3.6.1.4.1.1166.6.1.2.23.2 | no-access |
This table contains gx2Liteps specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.23.2.1 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
gx2LitepsAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.23.2.1.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
litepslabel12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.2 | displaystring | read-only |
The value of this object provides the label of the 12 Volt Analog parameter. |
litepsuom12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.3 | displaystring | read-only |
The value of this object provides the unit of measure of the 12 Volt Analog parameter. |
litepsmajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.4 | float | read-only |
The value of this object provides the Major High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsmajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.5 | float | read-only |
The value of this object provides the Major Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.6 | float | read-only |
The value of this object provides the Minor High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.7 | float | read-only |
The value of this object provides the Minor Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepscurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.8 | float | read-only |
The value of this object provides the Current value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsstateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.9 | integer | read-only |
The value of this object provides the state of the 12 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
litepsminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.10 | float | read-only |
The value of this object provides the minimum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsmaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.11 | float | read-only |
The value of this object provides the maximum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsalarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.12 | integer | read-only |
The value of this object provides the curent alarm state of the 12 Volt Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
litepslabel5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.13 | displaystring | read-only |
The value of this object provides the label of the Attenuator Setting Analog parameter. |
litepsuom5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.14 | displaystring | read-only |
The value of this object provides the Unit of Measure of the 5 Volt Analog parameter. |
litepsmajorHigh5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.15 | float | read-only |
The value of this object provides the Major High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsmajorLow5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.16 | float | read-only |
The value of this object provides the Major Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsminorHigh5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.17 | float | read-only |
The value of this object provides the Minor High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsminorLow5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.18 | float | read-only |
The value of this object provides the Minor Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepscurrentValue5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.19 | float | read-only |
The value of this object provides the Current value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsstateFlag5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.20 | integer | read-only |
The value of this object provides the state of the 5 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
litepsminValue5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.21 | float | read-only |
The value of this object provides the minimum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsmaxValue5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.22 | float | read-only |
The value of this object provides the maximum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsalarmState5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.23 | integer | read-only |
The value of this object provides the curent alarm state of the 5 Volt Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
litepslabel3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.24 | displaystring | read-only |
The value of this object provides the label of the 3 Anode Volt Analog parameter. |
litepsuom3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.25 | displaystring | read-only |
The value of this object provides the Unit of Measure of the 3.7V anode voltage analog parameter. |
litepsmajorHigh3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.26 | float | read-only |
The value of this object provides the Major High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsmajorLow3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.27 | float | read-only |
The value of this object provides the Major Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsminorHigh3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.28 | float | read-only |
The value of this object provides the Minor High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsminorLow3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.29 | float | read-only |
The value of this object provides the Minor Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepscurrentValue3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.30 | float | read-only |
The value of this object provides the Current value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsstateFlag3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.31 | integer | read-only |
The value of this object provides the state of the 3 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
litepsminValue3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.32 | float | read-only |
The value of this object provides the minimum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsmaxValue3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.33 | float | read-only |
The value of this object provides the maximum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
litepsalarmState3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.34 | integer | read-only |
The value of this object provides the curent alarm state of the 3.7V anode voltage analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
gx2LitepsStatusTable | 1.3.6.1.4.1.1166.6.1.2.23.3 | no-access |
This table contains gx2Liteps specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.23.3.2 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
gx2LitepsStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.23.3.2.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
litepslabelFan1Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.2 | displaystring | read-only |
The value of this object provides the label of the Fan 1 Status parameter. |
litepsvalueFan1Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.3 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
litepsstateflagFan1Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.4 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
litepslabelFan2Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.5 | displaystring | read-only |
The value of this object provides the label of the Fan 2 Status parameter. |
litepsvalueFan2Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.6 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
litepsstateflagFan2Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.7 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
trapLitepsConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.230.1 |
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapLitepsConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.230.2 |
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapLitepsFanCurrent1 | 1.3.6.1.4.1.1166.6.1.2.230.3 |
This trap is issued when Fan 1 is in an alarm condition. |
||
trapLitepsFanCurrent2 | 1.3.6.1.4.1.1166.6.1.2.230.4 |
This trap is issued when Fan 2 is in an alarm condition. |
||
trapLiteps12Volt | 1.3.6.1.4.1.1166.6.1.2.230.5 |
This trap is issued when the 12 Volts is in an alarm condition. |
||
trapLiteps5Volt | 1.3.6.1.4.1.1166.6.1.2.230.6 |
This trap is issued when the 5.1 Volts is in an alarm condition. |
||
trapLiteps3Volt | 1.3.6.1.4.1.1166.6.1.2.230.7 |
This trap is issued when the 3.7 Volts is in an alarm condition. |