OMNI-gx2drt4x-MIB: View SNMP OID List / Download MIB
VENDOR: GENERAL INSTRUMENT
Home | MIB: OMNI-gx2drt4x-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
gx2drt4xDescriptor | 1.3.6.1.4.1.1166.6.1.2.25.1 | |||
gx2drt4xAnalogTable | 1.3.6.1.4.1.1166.6.1.2.25.2 | no-access |
This table contains Gx2drt4x specific analog parameters with nominal,limits and current values. |
|
1.3.6.1.4.1.1166.6.1.2.25.2.1 | no-access |
This list contains the analog parameters and descriptions. |
||
gx2drt4xAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.25.2.1.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
drt4xlabelRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.2 | displaystring | read-only |
The value of this object provides the label of the RF Channel A Attenuation Analog parameter. |
drt4xuomRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.3 | displaystring | read-only |
The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. |
drt4xmajorHighRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.4 | float | read-only |
The value of this object provides the Major High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF) |
drt4xmajorLowRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.5 | float | read-only |
The value of this object provides the Major Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF) |
drt4xminorHighRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.6 | float | read-only |
The value of this object provides the Minor High alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. Set as the invalid float value (0xFFFFFFFF) |
drt4xminorLowRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.7 | float | read-only |
The value of this object provides the Minor Low alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. Set as the invalid float value (0xFFFFFFFF) |
drt4xvalueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.8 | float | read-write |
The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.9 | integer | read-only |
The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.10 | float | read-only |
The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.11 | float | read-only |
The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.12 | integer | read-only |
The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabelRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.13 | displaystring | read-only |
The value of this object provides the label of the RF Channel B Attenuation Analog parameter. |
drt4xuomRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.14 | displaystring | read-only |
The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter. |
drt4xmajorHighRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.15 | float | read-only |
The value of this object provides the Major High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xmajorLowRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.16 | float | read-only |
The value of this object provides the Major Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xminorHighRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.17 | float | read-only |
The value of this object provides the Minor High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xminorLowRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.18 | float | read-only |
The value of this object provides the Minor Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xvalueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.19 | float | read-write |
The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.20 | integer | read-only |
The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.21 | float | read-only |
The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.22 | float | read-only |
The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.23 | integer | read-only |
The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabelRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.24 | displaystring | read-only |
The value of this object provides the label of the RF Channel C Attenuation Analog parameter. |
drt4xuomRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.25 | displaystring | read-only |
The value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter. |
drt4xmajorHighRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.26 | float | read-only |
The value of this object provides the Major High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xmajorLowRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.27 | float | read-only |
The value of this object provides the Major Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xminorHighRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.28 | float | read-only |
The value of this object provides the Minor High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xminorLowRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.29 | float | read-only |
The value of this object provides the Minor Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xvalueRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.30 | float | read-write |
The value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.31 | integer | read-only |
The value of this object provides the state of the RF Channel C Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.32 | float | read-only |
The value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.33 | float | read-only |
The value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.34 | integer | read-only |
The value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabelRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.35 | displaystring | read-only |
The value of this object provides the label of the RF Channel D Attenuation Analog parameter. |
drt4xuomRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.36 | displaystring | read-only |
The value of this object provides the Unit of Measure of the RF Channel D Attenuation Analog parameter. |
drt4xmajorHighRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.37 | float | read-only |
The value of this object provides the Major High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xmajorLowRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.38 | float | read-only |
The value of this object provides the Major Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xminorHighRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.39 | float | read-only |
The value of this object provides the Minor High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xminorLowRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.40 | float | read-only |
The value of this object provides the Minor Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xvalueRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.41 | float | read-write |
The value of this object provides the Current value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.42 | integer | read-only |
The value of this object provides the state of the RF Channel D Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.43 | float | read-only |
The value of this object provides the minimum value the RF Channel D Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.44 | float | read-only |
The value of this object provides the maximum value the RF Channel D Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.45 | integer | read-only |
The value of this object provides the curent alarm state of the RF Channel D Attenuation Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabelLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.46 | displaystring | read-only |
The value of this object provides the label of the trip point level Analog parameter. |
drt4xuomLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.47 | displaystring | read-only |
The value of this object provides the Unit of Measure of the trip point level Analog parameter. |
drt4xmajorHighLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.48 | float | read-only |
The value of this object provides the Major High alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xmajorLowLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.49 | float | read-only |
The value of this object provides the Major Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xminorHighLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.50 | float | read-only |
The value of this object provides the Minor High alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xminorLowLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.51 | float | read-only |
The value of this object provides the Minor Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
drt4xvalueLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.52 | float | read-only |
The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input level. When trip point mode is ALARM_SWITCH, when optical power level is lower than trip point level (Set by this parameter), trip point alarm will be generated and RF output impedance will be changed to high impedance as >8.2K. This trip point level value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.53 | integer | read-only |
The value of this object provides the state of the trip point level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.54 | float | read-only |
The value of this object provides the minimum value the trip point level Analog parameter can achive. The minimum value is -19dBm This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.55 | float | read-only |
The value of this object provides the maximum value the trip point level Analog parameter can achive.which is -1dBm This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.56 | integer | read-only |
The value of this object provides the curent alarm state of the trip point level Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabelLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.57 | displaystring | read-only |
The value of this object provides the label of the Optical Power Current Analog parameter. |
drt4xuomLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.58 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter. |
drt4xmajorHighLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.59 | float | read-only |
The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmajorLowLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.60 | float | read-only |
The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorHighLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.61 | float | read-only |
The value of this object provides the Minor High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorLowLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.62 | float | read-only |
The value of this object provides the Minor Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xvalueLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.63 | float | read-only |
The value of this object provides the Current value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.64 | integer | read-only |
The value of this object provides the state of the Optical Power Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.65 | float | read-only |
The value of this object provides the minimum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.66 | float | read-only |
The value of this object provides the maximum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.67 | integer | read-only |
The value of this object provides the curent alarm state of the Optical Power Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabelLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.68 | displaystring | read-only |
The value of this object provides the label of the Laser TEC Temperature Analog parameter. |
drt4xuomLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.69 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Laser TEC Temperature Analog parameter. |
drt4xmajorHighLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.70 | float | read-only |
The value of this object provides the Major High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmajorLowLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.71 | float | read-only |
The value of this object provides the Major Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorHighLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.72 | float | read-only |
The value of this object provides the Minor High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorLowLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.73 | float | read-only |
The value of this object provides the Minor Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xvalueLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.74 | float | read-only |
The value of this object provides the Current value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.75 | integer | read-only |
The value of this object provides the state of the Laser TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.76 | float | read-only |
The value of this object provides the minimum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.77 | float | read-only |
The value of this object provides the maximum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.78 | integer | read-only |
The value of this object provides the curent alarm state of the Laser TEC Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabelLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.79 | displaystring | read-only |
The value of this object provides the label of the Laser TEC Current Analog parameter. |
drt4xuomLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.80 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Laser TEC Current Analog parameter. |
drt4xmajorHighLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.81 | float | read-only |
The value of this object provides the Major High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmajorLowLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.82 | float | read-only |
The value of this object provides the Major Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorHighLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.83 | float | read-only |
The value of this object provides the Minor High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorLowLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.84 | float | read-only |
The value of this object provides the Minor Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xvalueLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.85 | float | read-only |
The value of this object provides the Current value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.86 | integer | read-only |
The value of this object provides the state of the Laser TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.87 | float | read-only |
The value of this object provides the minimum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.88 | float | read-only |
The value of this object provides the maximum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.89 | integer | read-only |
The value of this object provides the curent alarm state of the Laser TEC Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabel12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.90 | displaystring | read-only |
The value of this object provides the label of the 12v power supply Current Analog parameter. |
drt4xuom12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.91 | displaystring | read-only |
The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter. |
drt4xmajorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.92 | float | read-only |
The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmajorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.93 | float | read-only |
The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.94 | float | read-only |
The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.95 | float | read-only |
The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xvalue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.96 | float | read-only |
The value of this object provides the Current value of the 12v power supply Current parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlag12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.97 | integer | read-only |
The value of this object provides the state of the 12v power supply Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.98 | float | read-only |
The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.99 | float | read-only |
The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmState12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.100 | integer | read-only |
The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabelModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.101 | displaystring | read-only |
The value of this object provides the label of the Module Temperature Analog parameter. |
drt4xuomModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.102 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
drt4xmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.103 | float | read-only |
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.104 | float | read-only |
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.105 | float | read-only |
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.106 | float | read-only |
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xvalueModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.107 | float | read-only |
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.108 | integer | read-only |
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.109 | float | read-only |
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.110 | float | read-only |
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.111 | integer | read-only |
The value of this object provides the curent alarm state of the Module Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
drt4xlabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.112 | displaystring | read-only |
The value of this object provides the label of the Fan Current Analog parameter. |
drt4xuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.113 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
drt4xmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.114 | float | read-only |
The value of this object provides the Major High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.115 | float | read-only |
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.116 | float | read-only |
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.117 | float | read-only |
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xvalueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.118 | float | read-only |
The value of this object provides the Current value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.119 | integer | read-only |
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.120 | float | read-only |
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.121 | float | read-only |
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
drt4xalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.122 | integer | read-only |
The value of this object provides the curent alarm state of the Fan Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
gx2drt4xDigitalTable | 1.3.6.1.4.1.1166.6.1.2.25.3 | no-access |
This table contains gx2drt4x specific digital parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.25.3.2 | no-access |
This list contains digital parameters and descriptions. |
||
gx2drt4xDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.25.3.2.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
drt4xlabelBaseITUChannel | 1.3.6.1.4.1.1166.6.1.2.25.3.2.2 | displaystring | read-only |
The value of this object provides the label of the Base ITU Channel Digital parameter. |
drt4xenumBaseITUChannel | 1.3.6.1.4.1.1166.6.1.2.25.3.2.3 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. |
drt4xvalueBaseITUChannel | 1.3.6.1.4.1.1166.6.1.2.25.3.2.4 | integer | read-only |
The value of this object is the value of the Base ITU Channel. There are 10 possible value: 1-ch20, 2-ch24, 3-ch28, 4-ch32, 5-ch36, 6-ch40, 7-ch44, 8-ch48, 9-ch52, 10-ch56. Enumeration: 'ch36': 5, 'ch24': 2, 'ch32': 4, 'ch20': 1, 'ch28': 3, 'ch56': 10, 'ch40': 6, 'ch52': 9, 'ch44': 7, 'ch48': 8. |
drt4xstateflagBaseITUChannel | 1.3.6.1.4.1.1166.6.1.2.25.3.2.5 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'readOnly': 2. |
drt4xlabelITUChannelSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.6 | displaystring | read-write |
The value of this object provides the label of the ITU Channel Setting Digital parameter. |
drt4xenumITUChannelSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.7 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. |
drt4xvalueITUChannelSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.8 | integer | read-write |
The value of this object is the value of the ITU Channel Setting. There are 4 possible value: 1-base (base ITU channel), 2-basePlus1 (base ITU Channel + 1), 3-basePlus2 (base ITU Channel + 2), and 4-basePlus3 (base ITU Channel + 3). Enumeration: 'base': 1, 'basePlus1': 2, 'basePlus2': 3, 'basePlus3': 4. |
drt4xstateflagITUChannelSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.9 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'readOnly': 2. |
drt4xlabelOpticalPowerSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.10 | displaystring | read-only |
The value of this object provides the label of the Optical Power Setting Digital parameter. This parameter defines the operating power level of the DRT-4X |
drt4xenumOpticalPowerSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.11 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
drt4xvalueOpticalPowerSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.12 | integer | read-write |
The value of this object is the setting of the Optical Power. There are two possible value: 1-low, and 2-high. Enumeration: 'high': 2, 'low': 1. |
drt4xstateflagOpticalPowerSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.13 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'readOnly': 2. |
drt4xlabelLaserControl | 1.3.6.1.4.1.1166.6.1.2.25.3.2.14 | displaystring | read-only |
The value of this object provides the label of the Laser Control Digital parameter. The Laser Control allows the DRT-4X laser to be turned off or on. |
drt4xenumLaserControl | 1.3.6.1.4.1.1166.6.1.2.25.3.2.15 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. |
drt4xvalueLaserControl | 1.3.6.1.4.1.1166.6.1.2.25.3.2.16 | integer | read-write |
The value of this object represents the Laser Control. There are two possible values: 1-off, and 2-on. Enumeration: 'on': 2, 'off': 1. |
drt4xstateflagLaserControl | 1.3.6.1.4.1.1166.6.1.2.25.3.2.17 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'readOnly': 2. |
drt4xlabelFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.25.3.2.18 | displaystring | read-only |
The value of this object provides the label of the Factory Default Reset Digital parameter. |
drt4xenumFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.25.3.2.19 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
drt4xvalueFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.25.3.2.20 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'on': 2, 'off': 1. |
drt4xstateflagFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.25.3.2.21 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
gx2drt4xStatusTable | 1.3.6.1.4.1.1166.6.1.2.25.4 | no-access |
This table contains gx2drt4x specific status parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.25.4.3 | no-access |
This list contains Status parameters and descriptions. |
||
gx2drt4xStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.25.4.3.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
drt4xlabelBoot | 1.3.6.1.4.1.1166.6.1.2.25.4.3.2 | displaystring | read-only |
The value of this object provides the label of the Boot Status parameter. |
drt4xvalueBoot | 1.3.6.1.4.1.1166.6.1.2.25.4.3.3 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
drt4xstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.25.4.3.4 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xlabelFlash | 1.3.6.1.4.1.1166.6.1.2.25.4.3.5 | displaystring | read-only |
The value of this object provides the label of the Flash Status parameter. |
drt4xvalueFlash | 1.3.6.1.4.1.1166.6.1.2.25.4.3.6 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
drt4xstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.25.4.3.7 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xlabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.25.4.3.8 | displaystring | read-only |
The value of this object provides the label of the Factory Data CRC Status parameter. |
drt4xvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.25.4.3.9 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
drt4xstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.25.4.3.10 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xlabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.11 | displaystring | read-only |
The value of this object provides the label of the Alarm Data Crc parameter. |
drt4xvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.12 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
drt4xstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.13 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xlabelCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.14 | displaystring | read-only |
The value of this object provides the label of the Calibration Data CRC parameter. |
drt4xvalueCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.15 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
drt4xstateflagCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.16 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
drt4xlabelHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.25.4.3.17 | displaystring | read-only |
The value of this object provides the label of the Module Hardware Status parameter. |
drt4xvalueHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.25.4.3.18 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
drt4xstateflagHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.25.4.3.19 | integer | read-only |
The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
gx2drt4xFactoryTable | 1.3.6.1.4.1.1166.6.1.2.25.5 | no-access |
This table contains gx2drt4x specific factory setting parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.25.5.4 | no-access |
This list contains Factory setting parameters and descriptions. |
||
gx2drt4xFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.25.5.4.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
drt4xbootControlByte | 1.3.6.1.4.1.1166.6.1.2.25.5.4.2 | integer | read-only |
The value of this object indicates which bank the firmware is currently being boot from. |
drt4xbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.25.5.4.3 | integer | read-only |
This object indicates the status of the last boot |
drt4xbank1CRC | 1.3.6.1.4.1.1166.6.1.2.25.5.4.4 | integer | read-only |
This object provides the CRC code of bank 0. |
drt4xbank2CRC | 1.3.6.1.4.1.1166.6.1.2.25.5.4.5 | integer | read-only |
This object provides the CRC code of bank 1. |
drt4xprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.25.5.4.6 | integer | read-only |
This object indicates if the EEPROM has been programmed |
drt4xfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.25.5.4.7 | integer | read-only |
This object provides the CRC code for the Factory data. |
drt4xcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.25.5.4.8 | integer | read-only |
This object indicates which of the Emnums will have the CRC calculated. Enumeration: 'alarm': 2, 'factory': 1. |
drt4xhourMeter | 1.3.6.1.4.1.1166.6.1.2.25.5.4.9 | integer | read-only |
This object provides the hour meter reading of the module. |
drt4xflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.25.5.4.10 | integer | read-only |
This object provides the number of times Bank 0 flash has been programmed. |
drt4xflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.25.5.4.11 | integer | read-only |
This object provides the number of times Bank 1 flash has been programmed. |
drt4xflashBankARev | 1.3.6.1.4.1.1166.6.1.2.25.5.4.12 | displaystring | read-only |
This object provides the revision of flash bank 0. |
drt4xflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.25.5.4.13 | displaystring | read-only |
This object provides the revision of flash bank 1. |
drt4xSubAgentRev | 1.3.6.1.4.1.1166.6.1.2.25.5.4.14 | displaystring | read-only |
This object provides the subagent revision of receiver module. |
trapdrt4xConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.250.1 |
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapdrt4xConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.250.2 |
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapdrt4xModulePlus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.250.3 |
This trap is issued when the Module +12V Supply Current goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapdrt4xModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.250.4 |
This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapdrt4xFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.250.5 |
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapdrt4xFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.250.6 |
This trap is issued when the detects an error during Flash memory operations. |
||
trapdrt4xBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.250.7 |
This trap is issued when the detects an error while booting from bank 0 or bank 1. |
||
trapdrt4xFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.250.8 |
This trap is issued when the Factory Data CRC is incorrect. |
||
trapdrt4xAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.250.9 |
This trap is issued when the Alarm Data CRC is incorrect. |
||
trapdrt4xCalibrationDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.250.10 |
This trap is issued when the Calibration Data CRC is incorrect. |
||
trapdrt4xHardwareErrorAlarm | 1.3.6.1.4.1.1166.6.1.2.250.11 |
This trap is issued when hardware is abnormal. |
||
trapdrt4xOpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.250.12 |
This trap is issued when the optical power is out of range. |
||
trapdrt4xTECTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.250.13 |
This trap is issued when the TEC Temperature is out of range. |
||
trapdrt4xTECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.250.14 |
This trap is issued when the TEC Current is out of range. |
||
trapdrt4xLaserBiasCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.250.15 |
This trap is issued when the Laser Bias Current is out of range. |
||
trapdrt4xResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.250.16 |
This trap is issued when the Factory Default Reset occurs. |
||
trapdrt4xLaserOnOffInfo | 1.3.6.1.4.1.1166.6.1.2.250.17 |
This trap is issued when the When the Laser turns on/off. |