OMNI-gx2drr3x-MIB: View SNMP OID List / Download MIB

VENDOR: GENERAL INSTRUMENT


 Home MIB: OMNI-gx2drr3x-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 gx2drr3xDescriptor 1.3.6.1.4.1.1166.6.1.2.13.1
 gx2drr3xAnalogTable 1.3.6.1.4.1.1166.6.1.2.13.2 no-access
This table contains gx2drr3x specific analog parameters with nominal,limits and current values.
     gx2drr3xAnalogEntry 1.3.6.1.4.1.1166.6.1.2.13.2.1 no-access
This list contains the analog parameters and descriptions.
         gx2drr3xAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.13.2.1.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         drrlabelRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.2 displaystring read-only
The value of this object provides the label of the RF Channel A Attenuation Analog parameter.
         drruomRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.3 displaystring read-only
The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter.
         drrmajorHighRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.4 float read-only
The value of this object provides the Major High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrmajorLowRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.5 float read-only
The value of this object provides the Major Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorHighRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.6 float read-only
The value of this object provides the Minor High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorLowRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.7 float read-only
The value of this object provides the Minor Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrcurrentValueRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.8 float read-write
The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrstateFlagRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.9 integer read-only
The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrminValueRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.10 float read-only
The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmaxValueRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.11 float read-only
The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drralarmStateRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.12 integer read-only
The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         drrlabelRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.13 displaystring read-only
The value of this object provides the label of the RF Channel B Attenuation Analog parameter.
         drruomRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.14 displaystring read-only
The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter.
         drrmajorHighRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.15 float read-only
The value of this object provides the Major High alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrmajorLowRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.16 float read-only
The value of this object provides the Major Low alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorHighRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.17 float read-only
The value of this object provides the Minor High alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorLowRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.18 float read-only
The value of this object provides the Minor Low alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrcurrentValueRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.19 float read-write
The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrstateFlagRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.20 integer read-only
The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrminValueRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.21 float read-only
The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmaxValueRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.22 float read-only
The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drralarmStateRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.23 integer read-only
The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         drrlabelRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.24 displaystring read-only
The value of this object provides the label of the RF Channel C Attenuation Analog parameter.
         drruomRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.25 displaystring read-only
The value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter.
         drrmajorHighRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.26 float read-only
The value of this object provides the Major High alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrmajorLowRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.27 float read-only
The value of this object provides the Major Low alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorHighRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.28 float read-only
The value of this object provides the Minor High alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorLowRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.29 float read-only
The value of this object provides the Minor Low alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrcurrentValueRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.30 float read-write
The value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrstateFlagRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.31 integer read-only
The value of this object provides the state of the RF Channel C Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrminValueRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.32 float read-only
The value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmaxValueRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.33 float read-only
The value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drralarmStateRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.13.2.1.34 integer read-only
The value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         drrlabelTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.35 displaystring read-only
The value of this object provides the label of the trip point level Analog parameter.
         drruomTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.36 displaystring read-only
The value of this object provides the Unit of Measure of the trip point level Analog parameter.
         drrmajorHighTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.37 float read-only
The value of this object provides the Major High alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrmajorLowTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.38 float read-only
The value of this object provides the Major Low alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorHighTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.39 float read-only
The value of this object provides the Minor High alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorLowTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.40 float read-only
The value of this object provides the Minor Low alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrcurrentValueTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.41 float read-write
The value of this object provides the Current value of the trippoint level Analog parameter. The trip point level set the custumer preferred optical input level. This parameter combined with trippoint mode(inside digital table) decides the trippoint alarm and RF channel output impedance. when optical power level is lower than trip point level(Set by this parameter) 1) When trip point mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will be changed to high impedance. 2) When trippoint mode is ALARM_ONLY, trippoint alarm will be generated but RF output inpedance remains to be low impedance. This trip point level value is a floating point number that is represented as an IEEE 32 bit number.
         drrstateFlagTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.42 integer read-only
The value of this object provides the state of the trip point level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrminValueTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.43 float read-only
The value of this object provides the minimum value the trip point level Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmaxValueTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.44 float read-only
The value of this object provides the maximum value the trip point level Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drralarmStateTrippointLevel 1.3.6.1.4.1.1166.6.1.2.13.2.1.45 integer read-only
The value of this object provides the curent alarm state of the trip point level Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         drrlabelOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.46 displaystring read-only
The value of this object provides the label of the Optical Power Current Analog parameter.
         drruomOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.47 displaystring read-only
The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter.
         drrmajorHighOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.48 float read-only
The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmajorLowOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.49 float read-only
The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrminorHighOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.50 float read-only
The value of this object provides the Minor High alarm value of the Optical Power Current Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorLowOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.51 float read-only
The value of this object provides the Minor Low alarm value of the Optical Power Current Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrcurrentValueOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.52 float read-only
The value of this object provides the Current value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrstateFlagOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.53 integer read-only
The value of this object provides the state of the Optical Power Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrminValueOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.54 float read-only
The value of this object provides the minimum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. The input optical power in lower than this value, drrcurrentValueOptCurrent will report -99dBm
         drrmaxValueOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.55 float read-only
The value of this object provides the maximum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. The input optical power in higher than this value, drrcurrentValueOptCurrent will report 99dBm
         drralarmStateOptCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.56 integer read-only
The value of this object provides the curent alarm state of the Optical Power Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         drrlabel12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.57 displaystring read-only
The value of this object provides the label of the 12v power supply Current Analog parameter.
         drruom12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.58 displaystring read-only
The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter.
         drrmajorHigh12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.59 float read-only
The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmajorLow12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.60 float read-only
The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrminorHigh12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.61 float read-only
The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrminorLow12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.62 float read-only
The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrcurrentValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.63 float read-only
The value of this object provides the Current value of the 12v power supply Current parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrstateFlag12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.64 integer read-only
The value of this object provides the state of the 12v power supply Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrminValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.65 float read-only
The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmaxValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.66 float read-only
The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drralarmState12VCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.67 integer read-only
The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         drrlabelModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.68 displaystring read-only
The value of this object provides the label of the Module Temperature Analog parameter.
         drruomModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.69 displaystring read-only
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
         drrmajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.70 float read-only
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.71 float read-only
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.72 float read-only
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.73 float read-only
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrcurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.74 float read-only
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrstateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.75 integer read-only
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrminValueModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.76 float read-only
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.77 float read-only
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drralarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.13.2.1.78 integer read-only
The value of this object provides the curent alarm state of the Module Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         drrlabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.79 displaystring read-only
The value of this object provides the label of the Fan Current Analog parameter.
         drruomFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.80 displaystring read-only
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
         drrmajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.81 float read-only
The value of this object provides the Major High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.82 float read-only
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number.
         drrminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.83 float read-only
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.84 float read-only
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)
         drrcurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.85 float read-only
The value of this object provides the Current value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number.
         drrstateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.86 integer read-only
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.87 float read-only
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drrmaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.88 float read-only
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         drralarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.13.2.1.89 integer read-only
The value of this object provides the curent alarm state of the Fan Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
 gx2drr3xDigitalTable 1.3.6.1.4.1.1166.6.1.2.13.3 no-access
This table contains gx2drr3x specific digital parameters with nominal and current values.
     gx2drr3xDigitalEntry 1.3.6.1.4.1.1166.6.1.2.13.3.2 no-access
This list contains digital parameters and descriptions.
         gx2drr3xDigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.13.3.2.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         drrlabelTrippointMode 1.3.6.1.4.1.1166.6.1.2.13.3.2.2 displaystring read-only
The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR3X
         drrenumTrippointMode 1.3.6.1.4.1.1166.6.1.2.13.3.2.3 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
         drrvalueTrippointMode 1.3.6.1.4.1.1166.6.1.2.13.3.2.4 integer read-write
The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml as high impedance Enumeration: 'alarm-and-Switch': 3, 'alarmOnly': 2, 'off': 1.
         drrstateflagTrippointMode 1.3.6.1.4.1.1166.6.1.2.13.3.2.5 integer read-only
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'readOnly': 2.
         drrlabelFrontPanelTest 1.3.6.1.4.1.1166.6.1.2.13.3.2.6 displaystring read-only
The value of this object provides the label of the Front panel test point Digital parameter.
         drrenumFrontPanelTest 1.3.6.1.4.1.1166.6.1.2.13.3.2.7 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         drrvalueFrontPanelTest 1.3.6.1.4.1.1166.6.1.2.13.3.2.8 integer read-write
The value of this object is the current value of Front panel RF test point Channel number Enumeration: 'chanA': 1, 'chanC': 3, 'chanB': 2.
         drrstateflagFrontPanelTest 1.3.6.1.4.1.1166.6.1.2.13.3.2.9 integer read-only
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'readOnly': 2.
         drrlabelFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.13.3.2.10 displaystring read-only
The value of this object provides the label of the Factory Default Reset Digital parameter.
         drrenumFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.13.3.2.11 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         drrvalueFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.13.3.2.12 integer read-write
The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter Enumeration: 'on': 2, 'off': 1.
         drrstateflagFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.13.3.2.13 integer read-only
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
 gx2drr3xStatusTable 1.3.6.1.4.1.1166.6.1.2.13.4 no-access
This table contains gx2drr3x specific status parameters with nominal and current values.
     gx2drr3xStatusEntry 1.3.6.1.4.1.1166.6.1.2.13.4.3 no-access
This list contains Status parameters and descriptions.
         gx2drr3xStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.13.4.3.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         drrlabelBoot 1.3.6.1.4.1.1166.6.1.2.13.4.3.2 displaystring read-only
The value of this object provides the label of the Boot Status parameter.
         drrvalueBoot 1.3.6.1.4.1.1166.6.1.2.13.4.3.3 integer read-only
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         drrstateflagBoot 1.3.6.1.4.1.1166.6.1.2.13.4.3.4 integer read-only
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrlabelFlash 1.3.6.1.4.1.1166.6.1.2.13.4.3.5 displaystring read-only
The value of this object provides the label of the Flash Status parameter.
         drrvalueFlash 1.3.6.1.4.1.1166.6.1.2.13.4.3.6 integer read-only
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         drrstateflagFlash 1.3.6.1.4.1.1166.6.1.2.13.4.3.7 integer read-only
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrlabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.13.4.3.8 displaystring read-only
The value of this object provides the label of the Factory Data CRC Status parameter.
         drrvalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.13.4.3.9 integer read-only
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         drrstateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.13.4.3.10 integer read-only
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrlabelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.13.4.3.11 displaystring read-only
The value of this object provides the label of the Alarm Data Crc parameter.
         drrvalueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.13.4.3.12 integer read-only
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         drrstateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.13.4.3.13 integer read-only
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrlabelHardwareStatus 1.3.6.1.4.1.1166.6.1.2.13.4.3.14 displaystring read-only
The value of this object provides the label of the Module Hardware Status parameter.
         drrvalueHardwareStatus 1.3.6.1.4.1.1166.6.1.2.13.4.3.15 integer read-only
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         drrstateflagHardwareStatus 1.3.6.1.4.1.1166.6.1.2.13.4.3.16 integer read-only
The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrlabelOpticTripPointStatus 1.3.6.1.4.1.1166.6.1.2.13.4.3.17 displaystring read-only
The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value
         drrvalueOpticTripPointStatus 1.3.6.1.4.1.1166.6.1.2.13.4.3.18 integer read-only
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         drrstateflagOpticTripPointStatus 1.3.6.1.4.1.1166.6.1.2.13.4.3.19 integer read-only
The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         drrlabelLinkStatus 1.3.6.1.4.1.1166.6.1.2.13.4.3.20 displaystring read-only
The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.
         drrvalueLinkStatus 1.3.6.1.4.1.1166.6.1.2.13.4.3.21 integer read-only
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         drrstateflagLinkStatus 1.3.6.1.4.1.1166.6.1.2.13.4.3.22 integer read-only
The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
 gx2drr3xFactoryTable 1.3.6.1.4.1.1166.6.1.2.13.5 no-access
This table contains gx2drr3x specific factory setting parameters with nominal and current values.
     gx2drr3xFactoryEntry 1.3.6.1.4.1.1166.6.1.2.13.5.4 no-access
This list contains Factory setting parameters and descriptions.
         gx2drr3xFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.13.5.4.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         drrbootControlByte 1.3.6.1.4.1.1166.6.1.2.13.5.4.2 integer read-only
The value of this object indicates which bank the firmware is currently being boot from.
         drrbootStatusByte 1.3.6.1.4.1.1166.6.1.2.13.5.4.3 integer read-only
This object indicates the status of the last boot
         drrbank1CRC 1.3.6.1.4.1.1166.6.1.2.13.5.4.4 integer read-only
This object provides the CRC code of bank 0.
         drrbank2CRC 1.3.6.1.4.1.1166.6.1.2.13.5.4.5 integer read-only
This object provides the CRC code of bank 1.
         drrprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.13.5.4.6 integer read-only
This object indicates if the EEPROM has been programmed
         drrfactoryCRC 1.3.6.1.4.1.1166.6.1.2.13.5.4.7 integer read-only
This object provides the CRC code for the Factory data.
         drrcalculateCRC 1.3.6.1.4.1.1166.6.1.2.13.5.4.8 integer read-only
This object indicates which of the Emnums will have the CRC calculated. Enumeration: 'alarm': 2, 'factory': 1.
         drrhourMeter 1.3.6.1.4.1.1166.6.1.2.13.5.4.9 integer read-only
This object provides the hour meter reading of the module.
         drrflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.13.5.4.10 integer read-only
This object provides the number of times Bank 0 flash has been programmed.
         drrflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.13.5.4.11 integer read-only
This object provides the number of times Bank 1 flash has been programmed.
         drrflashBankARev 1.3.6.1.4.1.1166.6.1.2.13.5.4.12 displaystring read-only
This object provides the revision of flash bank 0.
         drrflashBankBRev 1.3.6.1.4.1.1166.6.1.2.13.5.4.13 displaystring read-only
This object provides the revision of flash bank 1.
   trapdrrConfigChangeInteger 1.3.6.1.4.1.1166.6.1.2.130.1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
   trapdrrConfigChangeDisplayString 1.3.6.1.4.1.1166.6.1.2.130.2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
   trapdrr12VCurrentAlarm 1.3.6.1.4.1.1166.6.1.2.130.3
This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapdrrModuleTempAlarm 1.3.6.1.4.1.1166.6.1.2.130.4
This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapdrrFanCurrentAlarm 1.3.6.1.4.1.1166.6.1.2.130.5
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapdrrFlashAlarm 1.3.6.1.4.1.1166.6.1.2.130.6
This trap is issued when the detects an error during Flash memory operations.
   trapdrrBankBootAlarm 1.3.6.1.4.1.1166.6.1.2.130.7
This trap is issued when the detects an error while booting from bank 0 or bank 1.
   trapdrrAlarmDataCRCAlarm 1.3.6.1.4.1.1166.6.1.2.130.8
This trap is issued when the Alarm Data CRC is incorrect.
   trapdrrHardwareErrAlarm 1.3.6.1.4.1.1166.6.1.2.130.9
This trap is issued when hardware is abnormal.
   trapdrrOpticalSignalAlarm 1.3.6.1.4.1.1166.6.1.2.130.10
This trap is issued when the optical signal is beyond the reason range.
   trapdrrFactoryDataCRCAlarm 1.3.6.1.4.1.1166.6.1.2.130.11
This trap is issued when the Factory Data CRC is incorrect.
   trapdrrResetFactoryDefaultAlarm 1.3.6.1.4.1.1166.6.1.2.130.12
This trap is issued when the Factory Default Reset occurs.
   trapdrrTripPointAlarm 1.3.6.1.4.1.1166.6.1.2.130.13
This trap is issued when the Input optical power is lower than the custumer set trip point.
   trapdrrLinkAlarm 1.3.6.1.4.1.1166.6.1.2.130.14
This trap is issued when receiver is out of SYN with transmitter