OMNI-gx2Rx085BX4-MIB: View SNMP OID List / Download MIB
VENDOR: GENERAL INSTRUMENT
Home | MIB: OMNI-gx2Rx085BX4-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
gx2Rx085BX4Descriptor | 1.3.6.1.4.1.1166.6.1.2.32.1 | |||
gx2Rx085BX4AnalogTable | 1.3.6.1.4.1.1166.6.1.2.32.2 | no-access |
This table contains gx2Rx085BX4 specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.32.2.1 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
gx2Rx085BX4AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.32.2.1.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
rx085labelOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.2 | displaystring | read-only |
The value of this object provides the label of the Optical Power Analog parameter. |
rx085uomOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.3 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
rx085majorHighOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.4 | float | read-only |
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085majorLowOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.5 | float | read-only |
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorHighOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.6 | float | read-only |
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorLowOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.7 | float | read-only |
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085currentValueOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.8 | float | read-only |
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085stateFlagOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.9 | integer | read-only |
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085minValueOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.10 | float | read-only |
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085maxValueOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.11 | float | read-only |
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085alarmStateOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.12 | integer | read-only |
The value of this object provides the curent alarm state of the Optical Power Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
rx085labelOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.13 | displaystring | read-only |
The value of this object provides the label of the Optical Power Analog parameter. |
rx085uomOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.14 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
rx085majorHighOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.15 | float | read-only |
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085majorLowOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.16 | float | read-only |
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorHighOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.17 | float | read-only |
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorLowOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.18 | float | read-only |
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085currentValueOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.19 | float | read-only |
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085stateFlagOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.20 | integer | read-only |
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085minValueOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.21 | float | read-only |
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085maxValueOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.22 | float | read-only |
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085alarmStateOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.23 | integer | read-only |
The value of this object provides the curent alarm state of the Optical Power Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
rx085labelOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.24 | displaystring | read-only |
The value of this object provides the label of the Optical Power Analog parameter. |
rx085uomOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.25 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
rx085majorHighOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.26 | float | read-only |
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085majorLowOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.27 | float | read-only |
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorHighOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.28 | float | read-only |
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorLowOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.29 | float | read-only |
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085currentValueOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.30 | float | read-only |
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085stateFlagOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.31 | integer | read-only |
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085minValueOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.32 | float | read-only |
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085maxValueOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.33 | float | read-only |
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085alarmStateOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.34 | integer | read-only |
The value of this object provides the curent alarm state of the Optical Power Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
rx085labelOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.35 | displaystring | read-only |
The value of this object provides the label of the Optical Power Analog parameter. |
rx085uomOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.36 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
rx085majorHighOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.37 | float | read-only |
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085majorLowOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.38 | float | read-only |
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorHighOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.39 | float | read-only |
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorLowOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.40 | float | read-only |
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085currentValueOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.41 | float | read-only |
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085stateFlagOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.42 | integer | read-only |
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085minValueOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.43 | float | read-only |
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085maxValueOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.44 | float | read-only |
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085alarmStateOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.45 | integer | read-only |
The value of this object provides the curent alarm state of the Optical Power Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
rx085labelModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.46 | displaystring | read-only |
The value of this object provides the label of the Module Temperature Analog parameter. |
rx085uomModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.47 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
rx085majorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.48 | float | read-only |
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085majorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.49 | float | read-only |
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.50 | float | read-only |
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.51 | float | read-only |
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085currentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.52 | float | read-only |
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085stateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.53 | integer | read-only |
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085minValueModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.54 | float | read-only |
The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085maxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.55 | float | read-only |
The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085alarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.56 | integer | read-only |
The value of this object provides the curent alarm state of the Module Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
rx085labelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.57 | displaystring | read-only |
The value of this object provides the label of the Fan Current Analog parameter. |
rx085uomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.58 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
rx085majorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.59 | float | read-only |
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085majorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.60 | float | read-only |
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.61 | float | read-only |
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.62 | float | read-only |
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085currentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.63 | float | read-only |
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085stateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.64 | integer | read-only |
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085minValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.65 | float | read-only |
The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085maxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.66 | float | read-only |
The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085alarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.67 | integer | read-only |
The value of this object provides the curent alarm state of the Fan Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
rx085label12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.68 | displaystring | read-only |
The value of this object provides the label of the 12v Current Analog parameter. |
rx085uom12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.69 | displaystring | read-only |
The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
rx085majorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.70 | float | read-only |
The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085majorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.71 | float | read-only |
The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.72 | float | read-only |
The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085minorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.73 | float | read-only |
The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085currentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.74 | float | read-only |
The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085stateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.75 | integer | read-only |
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085minValue12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.76 | float | read-only |
The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085maxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.77 | float | read-only |
The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
rx085alarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.78 | integer | read-only |
The value of this object provides the curent alarm state of the 12v Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
gx2Rx085BX4DigitalTable | 1.3.6.1.4.1.1166.6.1.2.32.3 | no-access |
This table contains gx2Rx085BX4 specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.32.3.2 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
gx2Rx085BX4DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.32.3.2.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
rx085labelModeOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.2 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
rx085enumModeOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.3 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueModeOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.4 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'manual': 2, 'off': 1, 'agc': 3. |
rx085stateFlagModeOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.5 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.6 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
rx085enumWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.7 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.8 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'nM1590': 17, 'nM1450': 10, 'nM1570': 16, 'nM1610': 18, 'nM1490': 12, 'nM1430': 9, 'nM1370': 6, 'nM1470': 11, 'nM1550': 15, 'nM1350': 5, 'nM1270': 1, 'nM1310': 3, 'nM1510': 13, 'nM1390': 7, 'nM1330': 4, 'nM1410': 8, 'nM1530': 14, 'nM1290': 2. |
rx085stateFlagWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.9 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.10 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
rx085enumAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.11 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.12 | integer | read-write |
The value of this object is the current value of the parameter. It is an integer value from 0 to 60. Each increment represents 1/2 dB of attenuation from 0 to 30 dB. Where 0 = 0db and 60 = 30db |
rx085stateFlagAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.13 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.14 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
rx085enumSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.15 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.16 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'alarm-and-switch': 3, 'alarm-only': 2, 'off': 1. |
rx085stateFlagSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.17 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.18 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
rx085enumSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.19 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.20 | integer | read-write |
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
rx085stateFlagSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.21 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelModeTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.22 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
rx085enumModeTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.23 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueModeTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.24 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'manual': 2, 'off': 1, 'agc': 3. |
rx085stateFlagModeTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.25 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.26 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
rx085enumWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.27 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.28 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'nM1590': 17, 'nM1450': 10, 'nM1570': 16, 'nM1610': 18, 'nM1490': 12, 'nM1430': 9, 'nM1370': 6, 'nM1470': 11, 'nM1550': 15, 'nM1350': 5, 'nM1270': 1, 'nM1310': 3, 'nM1510': 13, 'nM1390': 7, 'nM1330': 4, 'nM1410': 8, 'nM1530': 14, 'nM1290': 2. |
rx085stateFlagWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.29 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.30 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
rx085enumAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.31 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.32 | integer | read-write |
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
rx085stateFlagAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.33 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.34 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
rx085enumSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.35 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.36 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'alarm-and-switch': 3, 'alarm-only': 2, 'off': 1. |
rx085stateFlagSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.37 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.38 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
rx085enumSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.39 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.40 | integer | read-write |
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
rx085stateFlagSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.41 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelModeThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.42 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
rx085enumModeThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.43 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueModeThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.44 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'manual': 2, 'off': 1, 'agc': 3. |
rx085stateFlagModeThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.45 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.46 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
rx085enumWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.47 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.48 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'nM1590': 17, 'nM1450': 10, 'nM1570': 16, 'nM1610': 18, 'nM1490': 12, 'nM1430': 9, 'nM1370': 6, 'nM1470': 11, 'nM1550': 15, 'nM1350': 5, 'nM1270': 1, 'nM1310': 3, 'nM1510': 13, 'nM1390': 7, 'nM1330': 4, 'nM1410': 8, 'nM1530': 14, 'nM1290': 2. |
rx085stateFlagWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.49 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.50 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
rx085enumAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.51 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.52 | integer | read-write |
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
rx085stateFlagAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.53 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.54 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
rx085enumSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.55 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.56 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'alarm-and-switch': 3, 'alarm-only': 2, 'off': 1. |
rx085stateFlagSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.57 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.58 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
rx085enumSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.59 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.60 | integer | read-write |
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
rx085stateFlagSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.61 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelModeFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.62 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
rx085enumModeFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.63 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueModeFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.64 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'manual': 2, 'off': 1, 'agc': 3. |
rx085stateFlagModeFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.65 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.66 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
rx085enumWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.67 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.68 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'nM1590': 17, 'nM1450': 10, 'nM1570': 16, 'nM1610': 18, 'nM1490': 12, 'nM1430': 9, 'nM1370': 6, 'nM1470': 11, 'nM1550': 15, 'nM1350': 5, 'nM1270': 1, 'nM1310': 3, 'nM1510': 13, 'nM1390': 7, 'nM1330': 4, 'nM1410': 8, 'nM1530': 14, 'nM1290': 2. |
rx085stateFlagWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.69 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.70 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
rx085enumAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.71 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.72 | integer | read-write |
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
rx085stateFlagAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.73 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.74 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
rx085enumSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.75 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.76 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'alarm-and-switch': 3, 'alarm-only': 2, 'off': 1. |
rx085stateFlagSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.77 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.78 | displaystring | read-only |
The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
rx085enumSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.79 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.80 | integer | read-write |
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
rx085stateFlagSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.81 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelModuleConfig | 1.3.6.1.4.1.1166.6.1.2.32.3.2.82 | displaystring | read-only |
The value of this object provides the label of the Factory Default Reset Digital parameter. |
rx085enumModuleConfig | 1.3.6.1.4.1.1166.6.1.2.32.3.2.83 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueModuleConfig | 1.3.6.1.4.1.1166.6.1.2.32.3.2.84 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'master': 2, 'slave': 1, 'burst': 3. |
rx085stateFlagModuleConfig | 1.3.6.1.4.1.1166.6.1.2.32.3.2.85 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelRevertTime | 1.3.6.1.4.1.1166.6.1.2.32.3.2.86 | displaystring | read-only |
The value of this object provides the label of the Factory Default Reset Digital parameter. |
rx085enumRevertTime | 1.3.6.1.4.1.1166.6.1.2.32.3.2.87 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueRevertTime | 1.3.6.1.4.1.1166.6.1.2.32.3.2.88 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'six-hundred-sec': 4, 'ten-sec': 2, 'one-sec': 1, 'sixty-sec': 3. |
rx085stateFlagRevertTime | 1.3.6.1.4.1.1166.6.1.2.32.3.2.89 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.32.3.2.90 | displaystring | read-only |
The value of this object provides the label of the Test point Select Digital parameter. |
rx085enumTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.32.3.2.91 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.32.3.2.92 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'four': 4, 'three': 3, 'two': 2, 'one': 1. |
rx085stateFlagTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.32.3.2.93 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.32.3.2.94 | displaystring | read-only |
The value of this object provides the label of the Factory Default Reset Digital parameter. |
rx085enumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.32.3.2.95 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
rx085valueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.32.3.2.96 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'on': 2, 'off': 1. |
rx085stateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.32.3.2.97 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
gx2Rx085BX4StatusTable | 1.3.6.1.4.1.1166.6.1.2.32.4 | no-access |
This table contains gx2Rx085BX4 specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.32.4.3 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
gx2Rx085BX4StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.32.4.3.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
rx085labelBoot | 1.3.6.1.4.1.1166.6.1.2.32.4.3.2 | displaystring | read-only |
The value of this object provides the label of the Boot Status Status parameter. |
rx085valueBoot | 1.3.6.1.4.1.1166.6.1.2.32.4.3.3 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.32.4.3.4 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelFlash | 1.3.6.1.4.1.1166.6.1.2.32.4.3.5 | displaystring | read-only |
The value of this object provides the label of the Flash Status Status parameter. |
rx085valueFlash | 1.3.6.1.4.1.1166.6.1.2.32.4.3.6 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.32.4.3.7 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.8 | displaystring | read-only |
The value of this object provides the label of the Factory Data CRC Status parameter. |
rx085valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.9 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.10 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.11 | displaystring | read-only |
The value of this object provides the label of the Alarm Data CRC Status parameter. |
rx085valueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.12 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.13 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.14 | displaystring | read-only |
The value of this object provides the label of the Calibration Data CRC Status parameter. |
rx085valueCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.15 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.16 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelHW | 1.3.6.1.4.1.1166.6.1.2.32.4.3.17 | displaystring | read-only |
The value of this object provides the label of the Hardware Status parameter. |
rx085valueHW | 1.3.6.1.4.1.1166.6.1.2.32.4.3.18 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagHW | 1.3.6.1.4.1.1166.6.1.2.32.4.3.19 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelOptSigOne | 1.3.6.1.4.1.1166.6.1.2.32.4.3.20 | displaystring | read-only |
The value of this object provides the label of the Optical Signal Status parameter. |
rx085valueOptSigOne | 1.3.6.1.4.1.1166.6.1.2.32.4.3.21 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagOptSigOne | 1.3.6.1.4.1.1166.6.1.2.32.4.3.22 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelOptSigTwo | 1.3.6.1.4.1.1166.6.1.2.32.4.3.23 | displaystring | read-only |
The value of this object provides the label of the Optical Signal Status parameter. |
rx085valueOptSigTwo | 1.3.6.1.4.1.1166.6.1.2.32.4.3.24 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagOptSigTwo | 1.3.6.1.4.1.1166.6.1.2.32.4.3.25 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelOptSigThree | 1.3.6.1.4.1.1166.6.1.2.32.4.3.26 | displaystring | read-only |
The value of this object provides the label of the Optical Signal Status parameter. |
rx085valueOptSigThree | 1.3.6.1.4.1.1166.6.1.2.32.4.3.27 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagOptSigThree | 1.3.6.1.4.1.1166.6.1.2.32.4.3.28 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelOptSigFour | 1.3.6.1.4.1.1166.6.1.2.32.4.3.29 | displaystring | read-only |
The value of this object provides the label of the Optical Signal Status parameter. |
rx085valueOptSigFour | 1.3.6.1.4.1.1166.6.1.2.32.4.3.30 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagOptSigFour | 1.3.6.1.4.1.1166.6.1.2.32.4.3.31 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
rx085labelBackupCable | 1.3.6.1.4.1.1166.6.1.2.32.4.3.32 | displaystring | read-only |
The value of this object provides the label of the Backup Cable Status parameter. |
rx085valueBackupCable | 1.3.6.1.4.1.1166.6.1.2.32.4.3.33 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
rx085stateflagBackupCable | 1.3.6.1.4.1.1166.6.1.2.32.4.3.34 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
gx2Rx085BX4FactoryTable | 1.3.6.1.4.1.1166.6.1.2.32.5 | no-access |
This table contains gx2Rx085BX4 specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.32.5.4 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
gx2Rx085BX4FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.32.5.4.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
rx085bootControlByte | 1.3.6.1.4.1.1166.6.1.2.32.5.4.2 | integer | read-only |
The value of this object indicates which bank the firmware is currently being boot from. |
rx085bootStatusByte | 1.3.6.1.4.1.1166.6.1.2.32.5.4.3 | integer | read-only |
This object indicates the status of the last boot |
rx085bank0CRC | 1.3.6.1.4.1.1166.6.1.2.32.5.4.4 | integer | read-only |
This object provides the CRC code of bank 0. |
rx085bank1CRC | 1.3.6.1.4.1.1166.6.1.2.32.5.4.5 | integer | read-only |
This object provides the CRC code of bank 1. |
rx085prgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.32.5.4.6 | integer | read-only |
This object indicates if the EEPROM has been programmed |
rx085factoryCRC | 1.3.6.1.4.1.1166.6.1.2.32.5.4.7 | integer | read-only |
This object provides the CRC code for the Factory data. |
rx085calculateCRC | 1.3.6.1.4.1.1166.6.1.2.32.5.4.8 | integer | read-only |
This object indicates which of the Emnums will have the CRC calculated. Enumeration: 'alarm': 3, 'tempComp': 4, 'factory': 1, 'calibration': 2. |
rx085hourMeter | 1.3.6.1.4.1.1166.6.1.2.32.5.4.9 | integer | read-only |
This object provides the hour meter reading of the module. |
rx085flashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.32.5.4.10 | integer | read-only |
This object provides the number of times the flash has been programmed on side A. |
rx085flashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.32.5.4.11 | integer | read-only |
This object provides the number of times the flash has been programmed on side B. |
rx085fwRev0 | 1.3.6.1.4.1.1166.6.1.2.32.5.4.12 | displaystring | read-only |
This object provides the Revision of the firmware stores in bank 0. |
rx085fwRev1 | 1.3.6.1.4.1.1166.6.1.2.32.5.4.13 | displaystring | read-only |
This object provides the Revision of the firmware stores in bank 1. |
trapRx085BX4ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.320.1 |
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapRx085BX4ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.320.2 |
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapRx085BX4OpticalPower1Alarm | 1.3.6.1.4.1.1166.6.1.2.320.3 |
This trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4OpticalPower2Alarm | 1.3.6.1.4.1.1166.6.1.2.320.4 |
This trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4OpticalPower3Alarm | 1.3.6.1.4.1.1166.6.1.2.320.5 |
This trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4OpticalPower4Alarm | 1.3.6.1.4.1.1166.6.1.2.320.6 |
This trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4ModuleTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.320.7 |
This trap is issued when the Rx085BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.320.8 |
This trap is issued when the Rx085BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Plus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.320.9 |
This trap is issued when the Rx085BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Boot0Alarm | 1.3.6.1.4.1.1166.6.1.2.320.10 |
This trap is issued when the Rx085BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Boot1Alarm | 1.3.6.1.4.1.1166.6.1.2.320.11 |
This trap is issued when the Rx085BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.320.12 |
This trap is issued when the Rx085BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.320.13 |
This trap is issued when the Rx085BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.320.14 |
This trap is issued when the Rx085BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4CalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.320.15 |
This trap is issued when the Rx085BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4DefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.320.16 |
This trap is issued when the Rx085BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Mode1Alarm | 1.3.6.1.4.1.1166.6.1.2.320.17 |
This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Mode2Alarm | 1.3.6.1.4.1.1166.6.1.2.320.18 |
This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Mode3Alarm | 1.3.6.1.4.1.1166.6.1.2.320.19 |
This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Mode4Alarm | 1.3.6.1.4.1.1166.6.1.2.320.20 |
This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Output1SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.320.21 |
This trap is issued when the Rx085BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Output2SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.320.22 |
This trap is issued when the Rx085BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Output3SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.320.23 |
This trap is issued when the Rx085BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4Output4SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.320.24 |
This trap is issued when the Rx085BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapRx085BX4RX1StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.320.25 |
This trap is issued when receiver 1 of the Rx085BX4 Module output is turned on or off. |
||
trapRx085BX4RX2StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.320.26 |
This trap is issued when receiver 2 of the Rx085BX4 Module output is turned on or off. |
||
trapRx085BX4RX3StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.320.27 |
This trap is issued when receiver 3 of the Rx085BX4 Module output is turned on or off. |
||
trapRx085BX4RX4StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.320.28 |
This trap is issued when receiver 4 of the Rx085BX4 Module output is turned on or off. |
||
trapRx085BX4BackupCableAlarm | 1.3.6.1.4.1.1166.6.1.2.320.29 |
This trap is issued when the slave receiver loses connection to the master receiver. |
||
trapRx085BX4OptPwr1BadAlarm | 1.3.6.1.4.1.1166.6.1.2.320.30 |
This trap is issued when the receiver 1 optical power level falls below the user set switching threshold. |
||
trapRx085BX4OptPwr2BadAlarm | 1.3.6.1.4.1.1166.6.1.2.320.31 |
This trap is issued when the receiver 2 optical power level falls below the user set switching threshold. |
||
trapRx085BX4OptPwr3BadAlarm | 1.3.6.1.4.1.1166.6.1.2.320.32 |
This trap is issued when the receiver 3 optical power level falls below the user set switching threshold. |
||
trapRx085BX4OptPwr4BadAlarm | 1.3.6.1.4.1.1166.6.1.2.320.33 |
This trap is issued when the receiver 4 optical power level falls below the user set switching threshold. |