OMNI-gx2RX1000-MIB: View SNMP OID List / Download MIB
VENDOR: GENERAL INSTRUMENT
Home | MIB: OMNI-gx2RX1000-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
gx2Rx1000Descriptor | 1.3.6.1.4.1.1166.6.1.2.9.1 | |||
gx2Rx1000AnalogTable | 1.3.6.1.4.1.1166.6.1.2.9.2 | no-access |
This table contains gx2Rx1000 specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.9.2.1 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
fprgx2Rx1000AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.2.1.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
fprlabelOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.2 | displaystring | read-only |
The value of this object provides the label of the Optical Power Analog parameter. |
fpruomOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.3 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
fprmajorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.4 | float | read-only |
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmajorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.5 | float | read-only |
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.6 | float | read-only |
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.7 | float | read-only |
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprcurrentValueOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.8 | float | read-only |
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprstateFlagOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.9 | integer | read-only |
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprminValueOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.10 | float | read-only |
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmaxValueOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.11 | float | read-only |
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fpralarmStateOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.12 | integer | read-only |
The value of this object provides the curent alarm state of the Optical Power Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
fprlabelModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.13 | displaystring | read-only |
The value of this object provides the label of the Module Temperature Analog parameter. |
fpruomModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.14 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
fprmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.15 | float | read-only |
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.16 | float | read-only |
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.17 | float | read-only |
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.18 | float | read-only |
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.19 | float | read-only |
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.20 | integer | read-only |
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.21 | float | read-only |
The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.22 | float | read-only |
The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fpralarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.23 | integer | read-only |
The value of this object provides the curent alarm state of the Module Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
fprlabelSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.24 | displaystring | read-only |
The value of this object provides the label of the Module Temperature Analog parameter. |
fpruomSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.25 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
fprmajorHighSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.26 | float | read-only |
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmajorLowSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.27 | float | read-only |
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorHighSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.28 | float | read-only |
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorLowSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.29 | float | read-only |
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprcurrentValueSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.30 | float | read-only |
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprstateFlagSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.31 | integer | read-only |
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprminValueSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.32 | float | read-only |
The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmaxValueSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.33 | float | read-only |
The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fpralarmStateSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.34 | integer | read-only |
The value of this object provides the curent alarm state of the Module Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
fprlabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.35 | displaystring | read-only |
The value of this object provides the label of the Fan Current Analog parameter. |
fpruomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.36 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
fprmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.37 | float | read-only |
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.38 | float | read-only |
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.39 | float | read-only |
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.40 | float | read-only |
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.41 | float | read-only |
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.42 | integer | read-only |
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.43 | float | read-only |
The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.44 | float | read-only |
The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fpralarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.45 | integer | read-only |
The value of this object provides the curent alarm state of the Fan Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
fprlabel12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.46 | displaystring | read-only |
The value of this object provides the label of the 12v Current Analog parameter. |
fpruom12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.47 | displaystring | read-only |
The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
fprmajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.48 | float | read-only |
The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.49 | float | read-only |
The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.50 | float | read-only |
The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.51 | float | read-only |
The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprcurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.52 | float | read-only |
The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprstateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.53 | integer | read-only |
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.54 | float | read-only |
The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fprmaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.55 | float | read-only |
The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
fpralarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.56 | integer | read-only |
The value of this object provides the curent alarm state of the 12v Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
gx2Rx1000DigitalTable | 1.3.6.1.4.1.1166.6.1.2.9.3 | no-access |
This table contains gx2Rx1000 specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.9.3.2 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
fprgx2Rx1000DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.3.2.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
fprlabelSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.2 | displaystring | read-only |
The value of this object provides the label of the RX1000's AttnSetting Digital parameter. |
fprenumSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.3 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0. |
fprvalueSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.4 | integer | read-write |
The value of this object is the current value of the parameter. It is an integer value from 0 to 6. Each increment represents 1/2 dB of slope from 0 to 3 dB. Where 0 = 0db and 6 = 3db |
fprstateFlagSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.5 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelAttnSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.6 | displaystring | read-only |
The value of this object provides the label of the RX1000's AttnSetting Digital parameter. |
fprenumAttnSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.7 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0. |
fprvalueAttnSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.8 | integer | read-write |
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/4 dB of attenuation from 0 to 10 dB. Where 0 = 0db and 40 = 10db |
fprstateFlagAttnSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.9 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelWavelength | 1.3.6.1.4.1.1166.6.1.2.9.3.2.10 | displaystring | read-only |
The value of this object provides the label of the RX1000's Wavelength Digital parameter. |
fprenumWavelength | 1.3.6.1.4.1.1166.6.1.2.9.3.2.11 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0. |
fprvalueWavelength | 1.3.6.1.4.1.1166.6.1.2.9.3.2.12 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'nM1310': 1, 'nM1550': 2. |
fprstateFlagWavelength | 1.3.6.1.4.1.1166.6.1.2.9.3.2.13 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.9.3.2.14 | displaystring | read-only |
The value of this object provides the label of the Factory Default Reset Digital parameter. |
fprenumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.9.3.2.15 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
fprvalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.9.3.2.16 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'on': 2, 'off': 1. |
fprstateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.9.3.2.17 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.9.3.2.18 | displaystring | read-only |
The value of this object provides the label of the RX1000's Switch Mode Threshold Digital parameter. |
fprenumSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.9.3.2.19 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0. |
fprvalueSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.9.3.2.20 | integer | read-write |
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 0.5 dB increments ranging from -9 to +1 dB. The user can enter a number from 0 to 20, where 0 = -9db and 20= +1db |
fprstateFlagSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.9.3.2.21 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.22 | displaystring | read-only |
The value of this object provides the label of the RX1000's Switch Mode Setting Digital parameter. |
fprenumSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.23 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0. |
fprvalueSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.24 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'alarm-and-switch': 3, 'alarm-only': 2, 'off': 1. |
fprstateFlagSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.25 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
gx2Rx1000StatusTable | 1.3.6.1.4.1.1166.6.1.2.9.4 | no-access |
This table contains gx2Rx1000 specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.9.4.3 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
fprgx2Rx1000StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.4.3.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
fprlabelBoot | 1.3.6.1.4.1.1166.6.1.2.9.4.3.2 | displaystring | read-only |
The value of this object provides the label of the Boot Status Status parameter. |
fprvalueBoot | 1.3.6.1.4.1.1166.6.1.2.9.4.3.3 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
fprstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.9.4.3.4 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelFlash | 1.3.6.1.4.1.1166.6.1.2.9.4.3.5 | displaystring | read-only |
The value of this object provides the label of the Flash Status Status parameter. |
fprvalueFlash | 1.3.6.1.4.1.1166.6.1.2.9.4.3.6 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
fprstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.9.4.3.7 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.8 | displaystring | read-only |
The value of this object provides the label of the Factory Data CRC Status parameter. |
fprvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.9 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
fprstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.10 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.11 | displaystring | read-only |
The value of this object provides the label of the Alarm Data CRC Status parameter. |
fprvalueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.12 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
fprstateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.13 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.14 | displaystring | read-only |
The value of this object provides the label of the Calibration Data CRC Status parameter. |
fprvalueCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.15 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
fprstateflagCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.16 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelFacCalSettingCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.17 | displaystring | read-only |
The value of this object provides the label of the Factor Cal Setting CRC Status parameter. |
fprvalueFacCalSettingCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.18 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
fprstateflagFacCalSettingCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.19 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
fprlabelInputSig | 1.3.6.1.4.1.1166.6.1.2.9.4.3.20 | displaystring | read-only |
The value of this object provides the label of the Input Sig Status parameter. |
fprvalueInputSig | 1.3.6.1.4.1.1166.6.1.2.9.4.3.21 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
fprstateflagInputSig | 1.3.6.1.4.1.1166.6.1.2.9.4.3.22 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
gx2Rx1000FactoryTable | 1.3.6.1.4.1.1166.6.1.2.9.5 | no-access |
This table contains gx2Rx1000 specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.9.5.4 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
fprgx2Rx1000FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.5.4.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
fprbootControlByte | 1.3.6.1.4.1.1166.6.1.2.9.5.4.2 | integer | read-only |
The value of this object indicates which bank the firmware is currently being boot from. |
fprbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.9.5.4.3 | integer | read-only |
This object indicates the status of the last boot |
fprbank0CRC | 1.3.6.1.4.1.1166.6.1.2.9.5.4.4 | integer | read-only |
This object provides the CRC code of bank 0. |
fprbank1CRC | 1.3.6.1.4.1.1166.6.1.2.9.5.4.5 | integer | read-only |
This object provides the CRC code of bank 1. |
fprprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.9.5.4.6 | integer | read-only |
This object indicates if the EEPROM has been programmed |
fprfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.9.5.4.7 | integer | read-only |
This object provides the CRC code for the Factory data. |
fprcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.9.5.4.8 | integer | read-only |
This object indicates which of the Emnums will have the CRC calculated. Enumeration: 'calSetting': 4, 'factory': 1, 'alarmdata': 3, 'calibration': 2. |
fprhourMeter | 1.3.6.1.4.1.1166.6.1.2.9.5.4.9 | integer | read-only |
This object provides the hour meter reading of the module. |
fprflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.9.5.4.10 | integer | read-only |
This object provides the number of times the flash has been programmed on side A. |
fprflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.9.5.4.11 | integer | read-only |
This object provides the number of times the flash has been programmed on side B. |
fprfwRev0 | 1.3.6.1.4.1.1166.6.1.2.9.5.4.12 | displaystring | read-only |
This object provides the Revision of the firmware stores in bank 0. |
fprfwRev1 | 1.3.6.1.4.1.1166.6.1.2.9.5.4.13 | displaystring | read-only |
This object provides the Revision of the firmware stores in bank 1. |
gx2Rx1000HoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.9.6 | no-access |
This table contains gx2Rx1000 specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.9.6.5 | no-access |
This list contains digital product class and the associated RF channel parameters and descriptions. |
||
gx2Rx1000HoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.6.5.1 | integer | read-only |
The value of this object is the index of the data object. |
gx2Rx1000HoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.9.6.5.2 | integer | read-only |
The value of this object identifies the index of the alarm object to be modified. |
gx2Rx1000HoldTimeData | 1.3.6.1.4.1.1166.6.1.2.9.6.5.3 | integer | read-write |
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
trapRX1000ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.90.1 |
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapRX1000ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.90.2 |
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapRX1000OpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.90.3 |
This trap is issued when the input Optical Power parameter goes out of range. |
||
trapRX1000ModuleTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.90.4 |
This trap is issued when the RX1000 Module's Temperature goes out of range. |
||
trapRX1000HeatSinkTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.90.5 |
This trap is issued when the RX1000 Heat Sink Temperature goes out of range. |
||
trapRX1000FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.90.6 |
This trap is issued when the RX1000 Module's Fan Currrent parameter goes out of range. |
||
trapRX1000Plus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.90.7 |
This trap is issued when the RX1000 Module's positive 12 volt current parameter goes out of range. |
||
trapRX1000OpticalSwitchAlarm | 1.3.6.1.4.1.1166.6.1.2.90.8 |
This trap is issued when the RX1000 Redundancy signal indicates a low input signal. |
||
trapRX1000Boot0Alarm | 1.3.6.1.4.1.1166.6.1.2.90.9 |
This trap is issued when the RX1000 Module's Bank 0 Boot sequence has detected an error. |
||
trapRX1000Boot1Alarm | 1.3.6.1.4.1.1166.6.1.2.90.10 |
This trap is issued when the RX1000 Module's Bank 1 Boot sequence has detected an error. |
||
trapRX1000FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.90.11 |
This trap is issued when the RX1000 Module's boot or flash programming sequence has detected a Flash error. |
||
trapRX1000AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.90.12 |
This trap is issued when the RX1000 Module detects an error calculating the alarm limit CRC. |
||
trapRX1000FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.90.13 |
This trap is issued when the RX1000 Module detects an error calculating the Factory data CRC. |
||
trapRX1000CalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.90.14 |
This trap is issued when the RX1000 Module detects an error calculating the Calibration data CRC. |
||
trapRX1000ResetFacDefault | 1.3.6.1.4.1.1166.6.1.2.90.15 |
This trap is issued when the RX1000 resets to factory defaults |
||
trapRX1000FacCalSettingCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.90.16 |
This trap is issued when the RX1000 Module detects factory calibration setting CRC alarm. |