Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
gx2Lm870CDescriptor | 1.3.6.1.4.1.1166.6.1.2.10.1 | |||
gx2lm870CAnalogTable | 1.3.6.1.4.1.1166.6.1.2.10.2 | no-access |
This table contains gx2Lm870C specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.10.2.1 | no-access |
This list contains the analog parameters and descriptions. |
||
gx2Lm870CAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.10.2.1.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
lm870ClabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.2 | displaystring | read-only |
The value of this object provides the label of the Fan Current Analog parameter. |
lm870CuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.3 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
lm870CmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.4 | float | read-only |
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.5 | float | read-only |
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.6 | float | read-only |
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.7 | float | read-only |
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.8 | float | read-only |
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.9 | integer | read-only |
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870CminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.10 | float | read-only |
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.11 | float | read-only |
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.12 | integer | read-only |
The value of this object provides the curent alarm state of the Fan Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
lm870Clabel12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.13 | displaystring | read-only |
The value of this object provides the label of the 12v Current Analog parameter. |
lm870Cuom12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.14 | displaystring | read-only |
The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
lm870CmajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.15 | float | read-only |
The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.16 | float | read-only |
The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.17 | float | read-only |
The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.18 | float | read-only |
The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CcurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.19 | float | read-only |
The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CstateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.20 | integer | read-only |
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870CminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.21 | float | read-only |
The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.22 | float | read-only |
The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CalarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.23 | integer | read-only |
The value of this object provides the curent alarm state of the 12v Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
lm870ClabelModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.24 | displaystring | read-only |
The value of this object provides the label of the Module Temperature Analog parameter. |
lm870CuomModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.25 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
lm870CmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.26 | float | read-only |
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.27 | float | read-only |
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.28 | float | read-only |
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.29 | float | read-only |
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.30 | float | read-only |
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.31 | integer | read-only |
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870CminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.32 | float | read-only |
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.33 | float | read-only |
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.34 | integer | read-only |
The value of this object provides the curent alarm state of the Module Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
lm870ClabelOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.35 | displaystring | read-only |
The value of this object provides the label of the OMI Offset Analog parameter. |
lm870CuomOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.36 | displaystring | read-only |
The value of this object provides the Unit of Measure of the OMI Offset Analog parameter. |
lm870CmajorHighOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.37 | float | read-only |
The value of this object provides the Major High alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmajorLowOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.38 | float | read-only |
The value of this object provides the Major Low alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorHighOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.39 | float | read-only |
The value of this object provides the Minor High alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorLowOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.40 | float | read-only |
The value of this object provides the Minor Low alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CcurrentValueOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.41 | float | read-only |
The value of this object provides the Current value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CstateFlagOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.42 | integer | read-only |
The value of this object provides the state of the OMI Offset Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870CminValueOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.43 | float | read-only |
The value of this object provides the minimum value the OMI Offset Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmaxValueOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.44 | float | read-only |
The value of this object provides the maximum value the OMI Offset Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CalarmStateOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.45 | integer | read-only |
The value of this object provides the curent alarm state of the OMI Offset Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
lm870ClabelOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.46 | displaystring | read-only |
The value of this object provides the label of the Optical Power Analog parameter. |
lm870CuomOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.47 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.. |
lm870CmajorHighOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.48 | float | read-only |
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmajorLowOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.49 | float | read-only |
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorHighOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.50 | float | read-only |
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorLowOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.51 | float | read-only |
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CcurrentValueOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.52 | float | read-only |
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CstateFlagOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.53 | integer | read-only |
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870CminValueOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.54 | float | read-only |
The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmaxValueOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.55 | float | read-only |
The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CalarmStateOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.56 | integer | read-only |
The value of this object provides the curent alarm state of the Optical Power Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
lm870ClabelLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.57 | displaystring | read-only |
The value of this object provides the label of the Laser Bias Current Analog parameter. |
lm870CuomLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.58 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
lm870CmajorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.59 | float | read-only |
The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmajorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.60 | float | read-only |
The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.61 | float | read-only |
The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.62 | float | read-only |
The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CcurrentValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.63 | float | read-only |
The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CstateFlagLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.64 | integer | read-only |
The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870CminValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.65 | float | read-only |
The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmaxValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.66 | float | read-only |
The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CalarmStateLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.67 | integer | read-only |
The value of this object provides the curent alarm state of the Laser Bias Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
lm870ClabelTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.68 | displaystring | read-only |
The value of this object provides the label of the TEC Current Analog parameter. |
lm870CuomTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.69 | displaystring | read-only |
The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
lm870CmajorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.70 | float | read-only |
The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmajorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.71 | float | read-only |
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.72 | float | read-only |
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.73 | float | read-only |
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CcurrentValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.74 | float | read-only |
The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CstateFlagTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.75 | integer | read-only |
The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870CminValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.76 | float | read-only |
The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmaxValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.77 | float | read-only |
The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CalarmStateTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.78 | integer | read-only |
The value of this object provides the curent alarm state of the TEC Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
lm870ClabelOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.79 | displaystring | read-only |
The value of this object provides the label of the OMI Offset Alarm Setpoint Analog parameter. |
lm870CuomOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.80 | displaystring | read-only |
The value of this object provides the Unit of Measure of the OMI Offset Alarm Setpoint Analog parameter.. |
lm870CmajorHighOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.81 | float | read-only |
The value of this object provides the Major High alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmajorLowOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.82 | float | read-only |
The value of this object provides the Major Low alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorHighOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.83 | float | read-only |
The value of this object provides the Minor High alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CminorLowOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.84 | float | read-only |
The value of this object provides the Minor Low alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CcurrentValueOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.85 | float | read-only |
The value of this object provides the Current value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CstateFlagOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.86 | integer | read-only |
The value of this object provides the state of the OMI Offset Alarm Setpoint Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870CminValueOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.87 | float | read-only |
The value of this object provides the minimum value the OMI Offset Alarm Setpoint Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CmaxValueOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.88 | float | read-only |
The value of this object provides the maximum value the OMI Offset Alarm Setpoint Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
lm870CalarmStateOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.89 | integer | read-only |
The value of this object provides the curent alarm state of the OMI Offset Alarm Setpoint Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
gx2lm870CDigitalTable | 1.3.6.1.4.1.1166.6.1.2.10.3 | no-access |
This table contains gx2Lm870C specific parameters with discrete values. |
|
1.3.6.1.4.1.1166.6.1.2.10.3.2 | no-access |
This list contains digital parameters and descriptions. |
||
gx2Lm870CDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.10.3.2.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
lm870ClabelOMIOffsetAlarms | 1.3.6.1.4.1.1166.6.1.2.10.3.2.2 | displaystring | read-only |
The value of this object provides the label of the OMI Offset Alarm mode Digital parameter. |
lm870CenumOMIOffsetAlarms | 1.3.6.1.4.1.1166.6.1.2.10.3.2.3 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the OMI Offset Alarm modeDigital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
lm870CvalueOMIOffsetAlarms | 1.3.6.1.4.1.1166.6.1.2.10.3.2.4 | integer | read-write |
The value of this object is the current value of the parameter. Note that the value to be read will always be 1 or 2 because the set value (3) is always changed to the on value (2) by the firmware Enumeration: 'on': 2, 'set': 3, 'off': 1. |
lm870CstateFlagOMIOffsetAlarms | 1.3.6.1.4.1.1166.6.1.2.10.3.2.5 | integer | read-only |
The value of this object provides the state of the OMI Offset Alarm mode Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.10.3.2.6 | displaystring | read-only |
The value of this object provides the label of the Reset to Factory Default Control Digital parameter. |
lm870CenumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.10.3.2.7 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the Reste to Factory Default Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
lm870CvalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.10.3.2.8 | integer | read-write |
The value of this object is the current value of the parameter. Enumeration: 'on': 2, 'off': 1. |
lm870CstateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.10.3.2.9 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelOMISetpoint | 1.3.6.1.4.1.1166.6.1.2.10.3.2.10 | displaystring | read-only |
The value of this object provides the label of the OMI Setpoint Digital parameter. |
lm870CenumOMISetpoint | 1.3.6.1.4.1.1166.6.1.2.10.3.2.11 | displaystring | read-only |
The value of this object represents the Enumeration values possible for the OMI Setpoint Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
lm870CvalueOMISetpoint | 1.3.6.1.4.1.1166.6.1.2.10.3.2.12 | integer | read-only |
The value of this object is the current value of the OMI Setpoint parameter. |
lm870CstateFlagOMISetpoint | 1.3.6.1.4.1.1166.6.1.2.10.3.2.13 | integer | read-only |
The value of this object provides the state of the OMI Setpoint Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
gx2lm870CStatusTable | 1.3.6.1.4.1.1166.6.1.2.10.4 | no-access |
This table contains gx2Lm870C specific parameters with current values. |
|
1.3.6.1.4.1.1166.6.1.2.10.4.3 | no-access |
This list contains Status parameters and descriptions. |
||
gx2Lm870CStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.10.4.3.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
lm870ClabelBoot | 1.3.6.1.4.1.1166.6.1.2.10.4.3.2 | displaystring | read-only |
The value of this object provides the label of the Boot Status Status parameter. |
lm870CvalueBoot | 1.3.6.1.4.1.1166.6.1.2.10.4.3.3 | integer | read-only |
The value of this object provides the current value of the boot status parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
lm870CstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.10.4.3.4 | integer | read-only |
The value of this object provides the state of the the boot status parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelFlash | 1.3.6.1.4.1.1166.6.1.2.10.4.3.5 | displaystring | read-only |
The value of this object provides the label of the Flash Status Status parameter. |
lm870CvalueFlash | 1.3.6.1.4.1.1166.6.1.2.10.4.3.6 | integer | read-only |
The value of this object provides the current value of the Flash Status parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
lm870CstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.10.4.3.7 | integer | read-only |
The value of this object provides the state current of the the Flash Status parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelRFOverload | 1.3.6.1.4.1.1166.6.1.2.10.4.3.8 | displaystring | read-only |
The value of this object provides the label for the RF Overload Status parameter. |
lm870CvalueRFOverload | 1.3.6.1.4.1.1166.6.1.2.10.4.3.9 | integer | read-only |
The value of this object provides the current value of the RF Overload parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
lm870CstateflagRFOverload | 1.3.6.1.4.1.1166.6.1.2.10.4.3.10 | integer | read-only |
The value of this object provides the current state of the RF Overload parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelRFPower | 1.3.6.1.4.1.1166.6.1.2.10.4.3.11 | displaystring | read-only |
The value of this object provides the label for the RF Power Status parameter. |
lm870CvalueRFPower | 1.3.6.1.4.1.1166.6.1.2.10.4.3.12 | integer | read-only |
The value of this object provides the current value of the RF Power parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
lm870CstateflagRFPower | 1.3.6.1.4.1.1166.6.1.2.10.4.3.13 | integer | read-only |
The value of this object provides the current state of the RF Power parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.14 | displaystring | read-only |
The value of this object provides the label of the Factory Data CRC Status parameter. |
lm870CvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.15 | integer | read-only |
The value of this object provides the current value of the Factory Data CRC parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
lm870CstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.16 | integer | read-only |
The value of this object provides the current state of the the Factory Data CRC parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.10.4.3.17 | displaystring | read-only |
The value of this object provides the label of the Alarm Data Crc parameter. |
lm870CvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.10.4.3.18 | integer | read-only |
The value of this object provides the current value of the Alarm Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
lm870CstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.10.4.3.19 | integer | read-only |
The value of this object provides the current state of the the Alarm Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelModSetDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.20 | displaystring | read-only |
The value of this object provides the label of the Module Settings Data Crc parameter. |
lm870CvalueModSetDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.21 | integer | read-only |
The value of this object provides the current value of the Module Settings Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
lm870CstateflagModSetDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.22 | integer | read-only |
The value of this object provides the current state of the the Module Settings Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelOptCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.23 | displaystring | read-only |
The value of this object provides the label of the Optical Calibration Data Crc parameter. |
lm870CvalueOptCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.24 | integer | read-only |
The value of this object provides the current value of the Optical Calibration Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
lm870CstateflagOptCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.25 | integer | read-only |
The value of this object provides the current state of the the Optical Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
lm870ClabelRFCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.26 | displaystring | read-only |
The value of this object provides the label of the RF Calibration Data Crc parameter. |
lm870CvalueRFCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.27 | integer | read-only |
The value of this object provides the current value of the RF Calibration Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
lm870CstateflagRFCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.28 | integer | read-only |
The value of this object provides the current state of the the RF Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
gx2lm870CFactoryTable | 1.3.6.1.4.1.1166.6.1.2.10.5 | no-access |
This table contains gx2Lm870C specific parameters with stored factory values. |
|
1.3.6.1.4.1.1166.6.1.2.10.5.4 | no-access |
This list contains Factory parameters and descriptions. |
||
gx2Lm870CFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.10.5.4.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
lm870CbootControlByte | 1.3.6.1.4.1.1166.6.1.2.10.5.4.2 | integer | read-only |
The value of this object indicates which bank the firmware is currently being boot from. |
lm870CbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.10.5.4.3 | integer | read-only |
This object indicates the status of the last boot |
lm870Cbank1CRC | 1.3.6.1.4.1.1166.6.1.2.10.5.4.4 | integer | read-only |
This object provides the CRC code of bank 0. |
lm870Cbank2CRC | 1.3.6.1.4.1.1166.6.1.2.10.5.4.5 | integer | read-only |
This object provides the CRC code of bank 1. |
lm870CprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.10.5.4.6 | integer | read-only |
This object indicates if the EEPROM has been programmed |
lm870CfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.10.5.4.7 | integer | read-only |
This object provides the CRC code for the Factory data. |
lm870CcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.10.5.4.8 | integer | read-only |
This object indicates which of the Emnums will have the CRC calculated. Enumeration: 'opticalCal': 4, 'rfCal': 5, 'alarm': 3, 'factory': 1, 'settings': 2. |
lm870ChourMeter | 1.3.6.1.4.1.1166.6.1.2.10.5.4.9 | integer | read-only |
This object provides the hour meter reading of the module. |
lm870CflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.10.5.4.10 | integer | read-only |
This object provides the number of times Bank 1 flash has been programmed. |
lm870CflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.10.5.4.11 | integer | read-only |
This object provides the number of times Bank 1 flash has been programmed. |
lm870CflashBankARev | 1.3.6.1.4.1.1166.6.1.2.10.5.4.12 | displaystring | read-only |
This object provides the revision of flash bank 0. |
lm870CflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.10.5.4.13 | displaystring | read-only |
This object provides the revision of flash bank 1. |
trapLM870CConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.100.1 |
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapLMCConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.100.2 |
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapLMCFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.100.3 |
This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapLMC12vAlarm | 1.3.6.1.4.1.1166.6.1.2.100.4 |
This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapLMCModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.100.5 |
This trap is issued when the Laser Module Temperature goes out of range. |
||
trapLMCRFPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.100.6 |
This trap is issued when the Laser Modules RF Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapLMCOPTPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.100.7 |
This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapLMCLaserBiasAlarm | 1.3.6.1.4.1.1166.6.1.2.100.8 |
This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapLMCTECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.100.9 |
This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapLMCFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.100.10 |
This trap is issued when the Laser Modules detects an error during Flash memory operations. |
||
trapLMCBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.100.11 |
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. |
||
trapLMCAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.100.12 |
This trap is issued when the Alarm Data CRC is incorrect. |
||
trapLMCModSetDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.100.13 |
This trap is issued when the Module Settings CRC is incorrect. |
||
trapLMCFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.100.14 |
This trap is issued when the Factory Data CRC is incorrect. |
||
trapLMCResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.100.15 |
This trap is issued when the Factory Default Reset occurs. |
||
trapLMCOPCalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.100.16 |
This trap is issued when the Optical Calibration Data CRC is incorrect. |
||
trapLMCRFCalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.100.17 |
This trap is issued when the RF Calibration Data CRC is incorrect. |
||
trapLMCRFOverloadAlarm | 1.3.6.1.4.1.1166.6.1.2.100.18 |
This trap is issued when the RF Overload alarm occurs. |
||
trapLMCOMIoffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.100.19 |
This trap is issued when an OMI Offset alarm occurs. |