OMNI-gx2CEB-MIB: View SNMP OID List / Download MIB
VENDOR: GENERAL INSTRUMENT
Home | MIB: OMNI-gx2CEB-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
gx2CEBDescriptor | 1.3.6.1.4.1.1166.6.1.2.20.1 | |||
gx2CEBAnalogTable | 1.3.6.1.4.1.1166.6.1.2.20.2 | no-access |
This table contains gx2CEB specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.20.2.1 | no-access |
This list contains the analog parameters and descriptions. |
||
gx2CEBAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.20.2.1.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
ceblabelModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.2 | displaystring | read-only |
The value of this object provides the label of the Module Temperature Analog parameter. |
cebuomModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.3 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
cebmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.4 | float | read-only |
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.5 | float | read-only |
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.6 | float | read-only |
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.7 | float | read-only |
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.8 | float | read-only |
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.9 | integer | read-only |
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
cebminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.10 | float | read-only |
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.11 | float | read-only |
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.12 | integer | read-only |
The value of this object provides the curent alarm state of the Module Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
ceblabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.13 | displaystring | read-only |
The value of this object provides the label of the Fan Current Analog parameter. |
cebuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.14 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
cebmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.15 | float | read-only |
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.16 | float | read-only |
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.17 | float | read-only |
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.18 | float | read-only |
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.19 | float | read-only |
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.20 | integer | read-only |
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
cebminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.21 | float | read-only |
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.22 | float | read-only |
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.23 | integer | read-only |
The value of this object provides the curent alarm state of the Fan Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
ceblabelAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.24 | displaystring | read-only |
The value of this object provides the label of the Analog Voltage number 01 Analog parameter. |
cebuomAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.25 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Analog Voltage number 01 Analog parameter. |
cebmajorHighAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.26 | float | read-only |
The value of this object provides the Major High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebmajorLowAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.27 | float | read-only |
The value of this object provides the Major Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorHighAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.28 | float | read-only |
The value of this object provides the Minor High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorLowAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.29 | float | read-only |
The value of this object provides the Minor Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebcurrentValueAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.30 | float | read-only |
The value of this object provides the Current value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebstateFlagAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.31 | integer | read-only |
The value of this object provides the state of the Analog Voltage number 01 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
cebminValueAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.32 | float | read-only |
The value of this object provides the minimum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebmaxValueAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.33 | float | read-only |
The value of this object provides the maximum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebalarmStateAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.34 | integer | read-only |
The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
ceblabelAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.35 | displaystring | read-only |
The value of this object provides the label of the Analog Voltage number 02 Analog parameter. |
cebuomAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.36 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Analog Voltage number 02 Analog parameter. |
cebmajorHighAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.37 | float | read-only |
The value of this object provides the Major High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebmajorLowAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.38 | float | read-only |
The value of this object provides the Major Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorHighAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.39 | float | read-only |
The value of this object provides the Minor High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorLowAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.40 | float | read-only |
The value of this object provides the Minor Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebcurrentValueAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.41 | float | read-only |
The value of this object provides the Current value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebstateFlagAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.42 | integer | read-only |
The value of this object provides the state of the Analog Voltage number 02 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
cebminValueAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.43 | float | read-only |
The value of this object provides the minimum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebmaxValueAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.44 | float | read-only |
The value of this object provides the maximum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebalarmStateAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.45 | integer | read-only |
The value of this object provides the curent alarm state of the Analog Voltage number 02 Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
ceblabelAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.46 | displaystring | read-only |
The value of this object provides the label of the Analog Voltage number 03 Analog parameter. |
cebuomAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.47 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Analog Voltage number 03 Analog parameter. |
cebmajorHighAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.48 | float | read-only |
The value of this object provides the Major High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebmajorLowAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.49 | float | read-only |
The value of this object provides the Major Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorHighAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.50 | float | read-only |
The value of this object provides the Minor High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorLowAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.51 | float | read-only |
The value of this object provides the Minor Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebcurrentValueAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.52 | float | read-only |
The value of this object provides the Current value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebstateFlagAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.53 | integer | read-only |
The value of this object provides the state of the Analog Voltage number 03 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
cebminValueAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.54 | float | read-only |
The value of this object provides the minimum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebmaxValueAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.55 | float | read-only |
The value of this object provides the maximum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebalarmStateAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.56 | integer | read-only |
The value of this object provides the curent alarm state of the Analog Voltage number 03 Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
ceblabelAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.57 | displaystring | read-only |
The value of this object provides the label of the Analog Voltage number 04 Analog parameter. |
cebuomAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.58 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Analog Voltage number 04 Analog parameter. |
cebmajorHighAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.59 | float | read-only |
The value of this object provides the Major High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebmajorLowAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.60 | float | read-only |
The value of this object provides the Major Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorHighAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.61 | float | read-only |
The value of this object provides the Minor High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorLowAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.62 | float | read-only |
The value of this object provides the Minor Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebcurrentValueAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.63 | float | read-only |
The value of this object provides the Current value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebstateFlagAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.64 | integer | read-only |
The value of this object provides the state of the Analog Voltage number 04 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
cebminValueAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.65 | float | read-only |
The value of this object provides the minimum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebmaxValueAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.66 | float | read-only |
The value of this object provides the maximum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebalarmStateAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.67 | integer | read-only |
The value of this object provides the curent alarm state of the Analog Voltage number 04 Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
ceblabelAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.68 | displaystring | read-only |
The value of this object provides the label of the Analog Voltage number 05 Analog parameter. |
cebuomAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.69 | displaystring | read-only |
The value of this object provides the Unit of Measure of the Analog Voltage number 05 Analog parameter. |
cebmajorHighAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.70 | float | read-only |
The value of this object provides the Major High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebmajorLowAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.71 | float | read-only |
The value of this object provides the Major Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorHighAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.72 | float | read-only |
The value of this object provides the Minor High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebminorLowAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.73 | float | read-only |
The value of this object provides the Minor Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
cebcurrentValueAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.74 | float | read-only |
The value of this object provides the Current value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebstateFlagAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.75 | integer | read-only |
The value of this object provides the state of the Analog Voltage number 05 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
cebminValueAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.76 | float | read-only |
The value of this object provides the minimum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebmaxValueAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.77 | float | read-only |
The value of this object provides the maximum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
cebalarmStateAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.78 | integer | read-only |
The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6. |
gx2CEBStatusTable | 1.3.6.1.4.1.1166.6.1.2.20.3 | no-access |
This table contains gx2CEB specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.20.3.2 | no-access |
This list contains Status parameters and descriptions. |
||
gx2CEBStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.20.3.2.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
ceblabelBoot | 1.3.6.1.4.1.1166.6.1.2.20.3.2.2 | displaystring | read-only |
The value of this object provides the label of the Boot Status Status parameter. |
cebvalueBoot | 1.3.6.1.4.1.1166.6.1.2.20.3.2.3 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
cebstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.20.3.2.4 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
ceblabelFlash | 1.3.6.1.4.1.1166.6.1.2.20.3.2.5 | displaystring | read-only |
The value of this object provides the label of the Flash Status Status parameter. |
cebvalueFlash | 1.3.6.1.4.1.1166.6.1.2.20.3.2.6 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
cebstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.20.3.2.7 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
ceblabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.20.3.2.8 | displaystring | read-only |
The value of this object provides the label of the Factory Data CRC Status parameter. |
cebvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.20.3.2.9 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
cebstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.20.3.2.10 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
ceblabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.20.3.2.11 | displaystring | read-only |
The value of this object provides the label of the Alarm Data Crc parameter. |
cebvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.20.3.2.12 | integer | read-only |
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4. |
cebstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.20.3.2.13 | integer | read-only |
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2. |
gx2CEBFactoryTable | 1.3.6.1.4.1.1166.6.1.2.20.4 | no-access |
This table contains gx2CEB specific parameters with nominal and current values. |
|
1.3.6.1.4.1.1166.6.1.2.20.4.3 | no-access |
This list contains Factory parameters and descriptions. |
||
gx2CEBFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.20.4.3.1 | integer | read-only |
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
cebbootControlByte | 1.3.6.1.4.1.1166.6.1.2.20.4.3.2 | integer | read-only |
The value of this object indicates which bank the firmware is currently being boot from. |
cebbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.20.4.3.3 | integer | read-only |
This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail) |
cebbank1CRC | 1.3.6.1.4.1.1166.6.1.2.20.4.3.4 | integer | read-only |
This object provides the CRC code of bank 0. The display formate for the data is Hex. |
cebbank2CRC | 1.3.6.1.4.1.1166.6.1.2.20.4.3.5 | integer | read-only |
This object provides the CRC code of bank 1.The display formate for the data is Hex. |
cebprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.20.4.3.6 | integer | read-only |
This object indicates if the EEPROM has been programmed |
cebfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.20.4.3.7 | integer | read-only |
This object provides the CRC code for the Factory data. |
cebcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.20.4.3.8 | integer | read-only |
This object indicates which of the Enums will have the CRC calculated. Enumeration: 'na': 2, 'alarm': 3, 'factory': 1. |
cebhourMeter | 1.3.6.1.4.1.1166.6.1.2.20.4.3.9 | integer | read-only |
This object provides the hour meter reading of the module. |
cebflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.20.4.3.10 | integer | read-only |
This object provides the number of times Bank 1 flash has been programmed. |
cebflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.20.4.3.11 | integer | read-only |
This object provides the number of times Bank 1 flash has been programmed. |
cebflashBankARev | 1.3.6.1.4.1.1166.6.1.2.20.4.3.12 | displaystring | read-only |
This object provides the revision of flash bank 0. The rev is 2 characters. |
cebflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.20.4.3.13 | displaystring | read-only |
This object provides the revision of flash bank 1. The rev is 2 characters. |
trapCEBConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.200.1 |
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapCEBConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.200.2 |
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
||
trapCEBfanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.200.3 |
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapCEBModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.200.4 |
This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
||
trapCEBFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.200.5 |
This trap is issued when the Laser Modules detects an error during Flash memory operations. |
||
trapCEBBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.200.6 |
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. |
||
trapCEBAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.200.7 |
This trap is issued when the Alarm Data CRC is incorrect. |
||
trapCEBFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.200.8 |
This trap is issued when the Factory Data CRC is incorrect. |