Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
raritan | 1.3.6.1.4.1.13742 |
This MIB describes the SNMP functions of the Schroff Varistar LHX heat exchanger supported by Raritan devices. |
||
lhxgw | 1.3.6.1.4.1.13742.9 | |||
traps | 1.3.6.1.4.1.13742.9.0 | |||
trapInformation | 1.3.6.1.4.1.13742.9.0.0 | |||
deviceName | 1.3.6.1.4.1.13742.9.0.0.1 | displaystring | no-access |
The user-defined name for the Device. |
deviceInetAddressType | 1.3.6.1.4.1.13742.9.0.0.2 | inetaddresstype | no-access |
The type of address format |
deviceInetIPAddress | 1.3.6.1.4.1.13742.9.0.0.3 | inetaddress | no-access |
The current IP address. A value of 0.0.0.0 indicates an error or an unset option. |
lhxErrorCode | 1.3.6.1.4.1.13742.9.0.0.4 | displaystring | no-access |
The LHX error code (F1 - F25, EP). |
portId | 1.3.6.1.4.1.13742.9.0.0.5 | integer32 | no-access |
A unique value for the physical port, the LHX controlller is connected to. Its value ranges between 1 and the value of portCount. |
probeId | 1.3.6.1.4.1.13742.9.0.0.6 | displaystring | no-access |
The physical Sensor ID (F1 - F7). |
fanId | 1.3.6.1.4.1.13742.9.0.0.7 | displaystring | no-access |
The Fan ID (M1 - M6). |
powerSupplyId | 1.3.6.1.4.1.13742.9.0.0.8 | displaystring | no-access |
The Power Supply ID (1, 2). |
oldSensorState | 1.3.6.1.4.1.13742.9.0.0.9 | sensorstateenumeration | no-access |
The old sensor state used in Sensor State Transition traps. |
sensorTypeId | 1.3.6.1.4.1.13742.9.0.0.10 | gwsensortypeenumeration | no-access |
A unique value for the type of sensor. |
sensorId | 1.3.6.1.4.1.13742.9.0.0.11 | integer32 | no-access |
A unique value for each sensor. Its value ranges between 1 and the value of sensorCount. |
oldOperationalState | 1.3.6.1.4.1.13742.9.0.0.12 | operationalstateenumeration | read-only |
The old operational state used in Operational State Transition traps. |
agentInetPortNumber | 1.3.6.1.4.1.13742.9.0.0.13 | inetportnumber | no-access |
The UDP port number used for accessing the SNMP agent on the device. Examples: If the associated device MIB (PX2-MIB, EMD-MIB) has deviceCascadeType set to portForwarding, then master: 50500 slave 1:50501 slave 2: 50502 ...... If cascading mode is not portForwarding and default (Standard) ports are being used, then port: 161 |
lhxSensorFailure | 1.3.6.1.4.1.13742.9.0.1 |
A sensor failure (broken or short circuit) occurred. |
||
lhxFanFailure | 1.3.6.1.4.1.13742.9.0.2 |
A fan motor failure occurred. |
||
lhxPowerSupplyFailure | 1.3.6.1.4.1.13742.9.0.3 |
A power supply failure occurred. |
||
lhxThresholdAirOutlet | 1.3.6.1.4.1.13742.9.0.4 |
The air outlet temperature threshold was crossed. |
||
lhxThresholdAirInlet | 1.3.6.1.4.1.13742.9.0.5 |
The air inlet temperature threshold was crossed. |
||
lhxThresholdWaterInlet | 1.3.6.1.4.1.13742.9.0.6 |
The water inlet temperature threshold was crossed. |
||
lhxDoorOpened | 1.3.6.1.4.1.13742.9.0.7 |
The door was opened. |
||
lhxMaximumCoolingRequest | 1.3.6.1.4.1.13742.9.0.8 |
Maximum cooling was requested. |
||
lhxEmergencyCooling | 1.3.6.1.4.1.13742.9.0.9 |
Emergency cooling was activated. |
||
lhxWaterLeak | 1.3.6.1.4.1.13742.9.0.10 |
Water leakage was detected. |
||
lhxThresholdHumidity | 1.3.6.1.4.1.13742.9.0.11 |
The humidity threshold was crossed. |
||
lhxExternalWaterCoolingFailure | 1.3.6.1.4.1.13742.9.0.12 |
An external water cooling failure occurred. |
||
lhxThresholdWaterOutlet | 1.3.6.1.4.1.13742.9.0.13 |
The water outlet temperature threshold was crossed. |
||
lhxParameterDataLoss | 1.3.6.1.4.1.13742.9.0.14 |
Data loss in parameter memory was detected. |
||
lhxStBusError | 1.3.6.1.4.1.13742.9.0.15 |
An ST-Bus communication error was detected. |
||
lhxCollectiveFault | 1.3.6.1.4.1.13742.9.0.16 |
An error was detected. |
||
gwSensorStateChange | 1.3.6.1.4.1.13742.9.0.17 |
Sensor State Change. |
||
gwLhxOperationalStateChange | 1.3.6.1.4.1.13742.9.0.18 |
Operational State Change. |
||
lhxVoltageLow | 1.3.6.1.4.1.13742.9.0.19 |
The supply voltage of an LHX became low. |
||
lhxBaseElectronicsFailure | 1.3.6.1.4.1.13742.9.0.20 |
The base electronics of an LHX controller failed. |
||
lhxCondenserPumpFailure | 1.3.6.1.4.1.13742.9.0.21 |
An LHX condenser pump failed. |
||
configuration | 1.3.6.1.4.1.13742.9.1 | |||
portCount | 1.3.6.1.4.1.13742.9.1.1 | integer32 | read-only |
The number of lhx units supported. |
sensorCountTable | 1.3.6.1.4.1.13742.9.1.2 | no-access |
A list of lhx sensor count extries. |
|
1.3.6.1.4.1.13742.9.1.2.1 | no-access |
An entry containing the number of lhx sensors of a certain type. |
||
sensorCount | 1.3.6.1.4.1.13742.9.1.2.1.1 | integer32 | read-only |
The number of sensors. |
lhx | 1.3.6.1.4.1.13742.9.1.3 | |||
lhxConfigurationTable | 1.3.6.1.4.1.13742.9.1.3.1 | no-access |
A list of lhx controller configuration extries. The number of entries is given by the value of portCount. |
|
1.3.6.1.4.1.13742.9.1.3.1.1 | no-access |
An entry containing parameters for an lhx. |
||
operationalState | 1.3.6.1.4.1.13742.9.1.3.1.1.1 | operationalstateenumeration | read-write |
The operational state of the lhx controller. To switch LHX power state while controller is connected, set operationalState to 1 (off) or 2 (on). Switching power state while LHX is disconnected or to 0 (disconnected) is undefined. |
setpointVentilators | 1.3.6.1.4.1.13742.9.1.3.1.1.2 | integer32 | read-write |
The setpoint of the ventilators. |
setpointWaterValve | 1.3.6.1.4.1.13742.9.1.3.1.1.3 | integer32 | read-write |
The setpoint of the water valve. |
defaultFanSpeed | 1.3.6.1.4.1.13742.9.1.3.1.1.4 | integer32 | read-write |
The 'default' fan speed during normal operation in per mill. Default is 80% (= 800). |
maximumCoolingState | 1.3.6.1.4.1.13742.9.1.3.1.1.5 | truthvalue | read-write |
Indicates whether maximum cooling was requested or not. To request maximum cooling, set maximumCoolingState to 1 (true). Setting maximumCoolingState to 2 (false) is undefined, set alertState to 2 (false) instead. |
alertState | 1.3.6.1.4.1.13742.9.1.3.1.1.6 | truthvalue | read-write |
Indicates whether LHX controler is in alert state or not. To acknowledge alert status, set alertState to 2 (false). Setting alertState to 1 (true) is undefined. |
model | 1.3.6.1.4.1.13742.9.1.3.1.1.7 | displaystring | read-only |
The model indentifier of an LHX controller. |
fwVersion | 1.3.6.1.4.1.13742.9.1.3.1.1.8 | displaystring | read-only |
The firmware version of an LHX controller. |
gwSensors | 1.3.6.1.4.1.13742.9.1.4 | |||
sensorConfigurationTable | 1.3.6.1.4.1.13742.9.1.4.1 | no-access |
A list of lhx sensor configuration extries. The number of entries is given by the value of portCount. |
|
1.3.6.1.4.1.13742.9.1.4.1.1 | no-access |
An entry containing parameters for an lhx. |
||
portIdx | 1.3.6.1.4.1.13742.9.1.4.1.1.1 | integer32 | no-access |
A unique value for each port. Its value ranges between 1 and the value of portCount. |
sensorTypeIdx | 1.3.6.1.4.1.13742.9.1.4.1.1.2 | integer32 | no-access |
A unique value for the type of sensor. |
sensorIdx | 1.3.6.1.4.1.13742.9.1.4.1.1.3 | integer32 | no-access |
A unique value for each sensor. Its value ranges between 1 and the value of sensorCount. |
sensorLabel | 1.3.6.1.4.1.13742.9.1.4.1.1.4 | displaystring | read-only |
The short ID of the sensor (e.g. F1, M2). |
sensorUnit | 1.3.6.1.4.1.13742.9.1.4.1.1.5 | sensorunitsenumeration | read-only |
The base units. This parameter does not apply to state sensors. |
sensorDecimalDigits | 1.3.6.1.4.1.13742.9.1.4.1.1.6 | unsigned32 | read-only |
The number of digits displayed to the right of the decimal point. This parameter does not apply to state sensors. |
sensorMaximum | 1.3.6.1.4.1.13742.9.1.4.1.1.7 | integer32 | read-only |
The largest possible value. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors. |
sensorMinimum | 1.3.6.1.4.1.13742.9.1.4.1.1.8 | integer32 | read-only |
The smallest possible value. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors. |
sensorHysteresis | 1.3.6.1.4.1.13742.9.1.4.1.1.9 | unsigned32 | read-write |
The hysteresis used for deassertions. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors. |
sensorLowerCriticalThreshold | 1.3.6.1.4.1.13742.9.1.4.1.1.10 | integer32 | read-write |
The lower critical threshold. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors. |
sensorLowerWarningThreshold | 1.3.6.1.4.1.13742.9.1.4.1.1.11 | integer32 | read-write |
The lower non-critical (warning) threshold. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors. |
sensorUpperCriticalThreshold | 1.3.6.1.4.1.13742.9.1.4.1.1.12 | integer32 | read-write |
The upper critical threshold. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors. |
sensorUpperWarningThreshold | 1.3.6.1.4.1.13742.9.1.4.1.1.13 | integer32 | read-write |
The upper non-critical (warning) threshold. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors. |
sensorEnabledThresholds | 1.3.6.1.4.1.13742.9.1.4.1.1.14 | bits | read-write |
A bit string which indicates which thresholds are enabled. This parameter does not apply to state sensors. Bits: 'lowerWarning': 1, 'upperCritical': 3, 'upperWarning': 2, 'lowerCritical': 0. |
sensorThresholdMaximum | 1.3.6.1.4.1.13742.9.1.4.1.1.15 | integer32 | read-only |
The largest possible threshold value. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors. |
sensorThresholdMinimum | 1.3.6.1.4.1.13742.9.1.4.1.1.16 | integer32 | read-only |
The smallest possible threshold value. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors. |
sensorName | 1.3.6.1.4.1.13742.9.1.4.1.1.17 | displaystring | read-only |
The descriptive ID of the sensor (e.g. Fan Speed 1). |
measurements | 1.3.6.1.4.1.13742.9.2 | |||
sensorMeasurementsTable | 1.3.6.1.4.1.13742.9.2.1 | no-access |
A list of external sensor entries. The number of entries is given by the value of sensorCount for the LHX. |
|
1.3.6.1.4.1.13742.9.2.1.1 | no-access |
An entry containing measurement objects for an external sensor. |
||
measurementsSensorIsAvailable | 1.3.6.1.4.1.13742.9.2.1.1.1 | truthvalue | read-only |
Is the sensor available? |
measurementsSensorState | 1.3.6.1.4.1.13742.9.2.1.1.2 | sensorstateenumeration | read-only |
The sensor state. |
measurementsSensorValue | 1.3.6.1.4.1.13742.9.2.1.1.3 | integer32 | read-only |
The sensor reading. This parameter does not apply to state sensors. |
measurementsSensorTimeStamp | 1.3.6.1.4.1.13742.9.2.1.1.4 | unsigned32 | read-only |
The sensor reading timestamp. |
conformance | 1.3.6.1.4.1.13742.9.3 | |||
compliances | 1.3.6.1.4.1.13742.9.3.1 | |||
complianceRev1 | 1.3.6.1.4.1.13742.9.3.1.1 |
The requirements for conformance to the LHX-MIB. |
||
groups | 1.3.6.1.4.1.13742.9.3.2 | |||
configurationGroup | 1.3.6.1.4.1.13742.9.3.2.1 |
A collection of objects representing configuration data. |
||
measurementsGroup | 1.3.6.1.4.1.13742.9.3.2.2 |
A collection of objects providing the measurement capability of LHX. |
||
trapInformationGroup | 1.3.6.1.4.1.13742.9.3.2.3 |
A collection of objects providing information in the traps. |
||
trapsGroup | 1.3.6.1.4.1.13742.9.3.2.4 |
A collection of traps. |