ITOUCH-CONCENTRATOR-MIB: View SNMP OID List / Download MIB

VENDOR: MRV COMMUNICATIONS


 Home MIB: ITOUCH-CONCENTRATOR-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 xConcentrator 1.3.6.1.4.1.33.25
       concentratorMode 1.3.6.1.4.1.33.25.1 integer read-write
This variable controls the ring mode of the chassis. Enumeration: 'fourRing': 2, 'twoRing': 1.
       concentratorManagement 1.3.6.1.4.1.33.25.2 integer read-write
This variable controls the ability to manage token ring concentrators. Enumeration: 'disabled': 1, 'enabled': 2.
       concentratorBuildTopology 1.3.6.1.4.1.33.25.3 integer read-write
This variable causes the chassis token ring topology database to be constructed. Enumeration: 'ready': 1, 'execute': 2.
       concentratorTopologyLastBuild 1.3.6.1.4.1.33.25.4 timeticks read-only
This variable contains the value of sysUpTime at the time the chassis token ring topology database was last constructed.
       concentratorChassisRingDefaults 1.3.6.1.4.1.33.25.5 integer read-write
This variable causes the chassis ring area of NVS to be set to defaults. Enumeration: 'ready': 1, 'execute': 2.
       concentratorSlotTable 1.3.6.1.4.1.33.25.6 no-access
Table of descriptive and status information about a Token Ring Concentrator.
           concentratorSlotEntry 1.3.6.1.4.1.33.25.6.1 no-access
An entry in the table containing information about a specific concentrator.
               concentratorSlotIndex 1.3.6.1.4.1.33.25.6.1.1 integer read-only
This variable identifies the slot of the chassis.
               concentratorSlotIOType 1.3.6.1.4.1.33.25.6.1.2 iotype read-only
This variable represents the type of the I/O card.
               concentratorSlotIOFirmwareVersion 1.3.6.1.4.1.33.25.6.1.3 integer read-only
This variable represents the revision level of the firmware on the I/O card.
               concentratorSlotIOOperStatus 1.3.6.1.4.1.33.25.6.1.4 integer read-only
This variable represents the current operating status of the I/O card. Enumeration: 'invalidConfigStorage': 14, 'paramRequested': 5, 'maxserverCard': 13, 'dumping': 4, 'paramLoading': 6, 'running': 7, 'loading': 2, 'attended': 9, 'initializing': 8, 'securityLockdown': 15, 'loadRequested': 1, 'internal10': 10, 'internal11': 11, 'dumpRequested': 3, 'inhibited': 12.
               concentratorSlotUptime 1.3.6.1.4.1.33.25.6.1.5 timeticks read-only
This variable contains the value of sysUpTime at the time the concentrator was last reset.
               concentratorSlotNumPorts 1.3.6.1.4.1.33.25.6.1.6 integer read-only
This variable represents the number of Token Ring ports supported by the concentrator.
       concentratorSlotRingTable 1.3.6.1.4.1.33.25.7 no-access
Table of descriptive and status information about the rings of a controller.
           concentratorSlotRingEntry 1.3.6.1.4.1.33.25.7.1 no-access
An entry in the table containing information about a specific ring.
               concentratorSlotSlotIndex 1.3.6.1.4.1.33.25.7.1.1 integer read-only
This variable identifies the slot of the chassis.
               concentratorSlotRingIndex 1.3.6.1.4.1.33.25.7.1.2 integer read-only
This variable identifies the ring within the slot.
               concentratorSlotRingAdminName 1.3.6.1.4.1.33.25.7.1.3 displaystring read-write
This variable represents the user defined name of the ring.
               concentratorSlotRingAdminSpeed 1.3.6.1.4.1.33.25.7.1.4 integer read-write
This variable represents the user defined speed of the ring. Enumeration: 'mbps16': 2, 'mbps4': 1.
               concentratorSlotRingAdminState 1.3.6.1.4.1.33.25.7.1.5 integer read-write
This variable defines whether the slot ring is to be inserted into the defined chassis ring or is to be isolated. Enumeration: 'inserted': 2, 'isolated': 1.
               concentratorSlotRingZero 1.3.6.1.4.1.33.25.7.1.6 integer read-write
This variable is used to control the slot ring's counters. The agent always returns 'ready' for this value. Setting the value to 'ready' has no effect. Enumeration: 'ready': 1, 'execute': 2.
               concentratorSlotRingSinceZero 1.3.6.1.4.1.33.25.7.1.7 timeticks read-only
This variable reflects the number of time ticks since the counters were last zeroed. This variable is set to zero when concentratoSlotRingZero is written with the value 2
               concentratorSlotRingChassisRing 1.3.6.1.4.1.33.25.7.1.8 letter read-write
This variable represents the chassis ring into which the slot ring is to be inserted if it is to be inserted.
               concentratorSlotRingOperName 1.3.6.1.4.1.33.25.7.1.9 displaystring read-only
This variable represents the name currently being used to identify the slot ring. If inserted, this name will be the user defined name of the chassis ring into which it is inserted. If isolated, this name will be the user defined name of the slot ring.
               concentratorSlotRingOperSpeed 1.3.6.1.4.1.33.25.7.1.10 integer read-only
This variable represents the current speed of the slot ring. If inserted, this speed will be the user defined speed of the chassis ring into which it is inserted. If isolated, this speed will be the user defined speed of the slot ring. Enumeration: 'mbps16': 2, 'mbps4': 1.
               concentratorSlotRingOperState 1.3.6.1.4.1.33.25.7.1.11 integer read-only
This variable indicates whether the slot ring is inserted into the defined chassis ring or is isolated. Enumeration: 'inserted': 2, 'isolated': 1.
               concentratorSlotRingChassisRingsAllowed 1.3.6.1.4.1.33.25.7.1.12 octet string read-only
The list of chassis rings into which this slot ring may be inserted. The OCTET STRING contains a bit map, with a bit for 'none' (indicating it may be isolated) and one bit for each chassis ring, and enough octets for all chassis rings. The high order bit of the first octet corresponds to 'none' and each subsequent bit in ascending order corresponds to the chassis rings in order beginning with A.
       concentratorChassisRingTable 1.3.6.1.4.1.33.25.8 no-access
Table of descriptive and status information about the rings of a the chassis.
           concentratorChassisRingEntry 1.3.6.1.4.1.33.25.8.1 no-access
An entry in the table containing information about a specific ring.
               concentratorChassisRingIndex 1.3.6.1.4.1.33.25.8.1.1 letter read-only
This variable identifies the ring of the chassis.
               concentratorChassisRingName 1.3.6.1.4.1.33.25.8.1.2 displaystring read-write
This variable represents the name of the ring. All segments of a given chassis ring will have the same base name, All segment of that ring will appear as 'baseNamex' where x is the identified segment
               concentratorChassisRingSpeed 1.3.6.1.4.1.33.25.8.1.3 integer read-write
This variable indicates the speed of the ring segment. All segments of a given chassis ring are at the same speed. Enumeration: 'mbps16': 2, 'mbps4': 1.
               concentratorChassisRingTopologyChanges 1.3.6.1.4.1.33.25.8.1.4 counter read-only
This variable reflects the number of times the topology has changed for this ring. This variable is set to zero when concentratorChassisRingZero is written with the value 2.
               concentratorChassisRingZero 1.3.6.1.4.1.33.25.8.1.5 integer read-write
This variable is used to control the ring's counters. The agent always returns 'ready' for this value. Setting the value to 'ready' has no effect. Enumeration: 'ready': 1, 'execute': 2.
               concentratorChassisRingSinceZero 1.3.6.1.4.1.33.25.8.1.6 timeticks read-only
This variable reflects the number of time ticks since the counters were last zeroed. This variable is set to zero when concentratoChassisRingZero is written with the value 2
       concentratorChassisRingTopologyTable 1.3.6.1.4.1.33.25.9 no-access
Table of descriptive and status information about the segments of the chassis rings.
           concentratorChassisRingTopologyEntry 1.3.6.1.4.1.33.25.9.1 no-access
An entry in the table containing information about a specific ring segment.
               concentratorChassisRingTopologySlotIndex 1.3.6.1.4.1.33.25.9.1.1 integer read-only
This variable identifies a slot number that is included in the ring segment.
               concentratorChassisRingTopologyRingIndex 1.3.6.1.4.1.33.25.9.1.2 letter read-only
This variable identifies the ring of the chassis.
               concentratorChassisRingTopologyWrapUp 1.3.6.1.4.1.33.25.9.1.3 integer read-only
This variable represents the upper wrap state for the chassis ring which passes through this slot. By setting this variable to Wrap, the user can create a segment which would contain this slot, and all slots above this one which are on the same segment. Enumeration: 'wrap': 2, 'unwrap': 1.
               concentratorChassisRingTopologyWrapDown 1.3.6.1.4.1.33.25.9.1.4 integer read-only
This variable represents the lower wrap state for the chassis ring which passes through this slot. By setting this variable to Wrap, the user can create a segment which would contain this slot, and all slots below this one which are on the same segment. Enumeration: 'wrap': 2, 'unwrap': 1.
               concentratorChassisRingTopologyUpState 1.3.6.1.4.1.33.25.9.1.5 integer read-only
This variable represents the type of upper wrap for the chassis ring which passes through this slot. Enumeration: 'dynamic': 2, 'static': 1.
               concentratorChassisRingTopologyDownState 1.3.6.1.4.1.33.25.9.1.6 integer read-only
This variable represents the type of lower wrap for the chassis ring which passes through this slot. Enumeration: 'dynamic': 2, 'static': 1.
               concentratorChassisRingTopologySegment 1.3.6.1.4.1.33.25.9.1.7 integer read-only
This variable represents the segment number for the chassis ring which passes through this slot.
               concentratorChassisRingTopologyName 1.3.6.1.4.1.33.25.9.1.8 displaystring read-only
This variable represents the name of the ring segment. The ring segment name is the base ring name with '-segment number' appended to the end.
               concentratorChassisRingTopologySpeed 1.3.6.1.4.1.33.25.9.1.9 integer read-only
This variable indicates the speed of the ring segment. All segments of a given chassis ring are at the same speed as the parent ring. Enumeration: 'mbps16': 2, 'mbps4': 1.
               concentratorChassisRingTopologyCardType 1.3.6.1.4.1.33.25.9.1.10 iotype read-only
This variable represents the type of the I/O card.
               concentratorChassisRingTopologyAutoUpChanges 1.3.6.1.4.1.33.25.9.1.11 counter read-only
This variable reflects the number of times the topology has changed for this ring due to a dynamic wrap up. This variable is set to zero when concentratorSlotRingZero is written with the value 2.
               concentratorChassisRingTopologyAutoDownChanges 1.3.6.1.4.1.33.25.9.1.12 counter read-only
This variable reflects the number of times the topology has changed for this ring due to a dynamic wrap down. This variable is set to zero when concentratorSlotRingZero is written with the value 2.
       concentratorPortTable 1.3.6.1.4.1.33.25.10 no-access
Table of information and status concerning the ports of a concentrator.
             concentratorPortEntry 1.3.6.1.4.1.33.25.10.1 no-access
An entry in the table containing control and status information for a port.
                 concentratorPortSlotIndex 1.3.6.1.4.1.33.25.10.1.1 integer read-only
This variable identifies the slot of the chassis.
                 concentratorPortIndex 1.3.6.1.4.1.33.25.10.1.2 integer read-only
This variable identifies target port.
                 concentratorPortName 1.3.6.1.4.1.33.25.10.1.3 displaystring read-write
This variable represents the user defined name of the port.
                 concentratorPortType 1.3.6.1.4.1.33.25.10.1.4 integer read-only
This variable represents the type of connector provided for the port. Enumeration: 'rj45': 1, 'fiber': 2.
                 concentratorPortZero 1.3.6.1.4.1.33.25.10.1.5 integer read-write
This variable is used to control the ports counters. The agent always returns 'ready' for this value. Setting the value to 'ready' has no effect. Enumeration: 'ready': 1, 'execute': 2.
                 concentratorPortSinceZero 1.3.6.1.4.1.33.25.10.1.6 timeticks read-only
This variable reflects the number of time ticks since the counters were las zeroed. This variable is set to zero when concentratorPortZero is written with the value 2
                 concentratorPortAdminState 1.3.6.1.4.1.33.25.10.1.7 integer read-write
This variable reflects the enable/disable state of the port. Enumeration: 'disabled': 1, 'enabled': 2.
                 concentratorPortOperState 1.3.6.1.4.1.33.25.10.1.8 integer read-only
This variable reflects the enable/disable state of the port. Enumeration: 'notInserted': 2, 'inserted': 1, 'rateMismatch': 3.
                 concentratorPortInsertions 1.3.6.1.4.1.33.25.10.1.9 counter read-only
This variable reflects the number of times the port was inserted into the ring.
                 concentratorPortInsertFailures 1.3.6.1.4.1.33.25.10.1.10 counter read-only
This variable reflects the number of times the port was not inserted due to a data rate mismatch.
                 concentratorPortAdminInsert 1.3.6.1.4.1.33.25.10.1.11 integer read-write
This variable reflects the desired insertion of the port. Auto indicates to insert the port into the first slot ring with a matching data rate beginning with 1. Enumeration: 'ring9': 10, 'ring8': 9, 'ring7': 8, 'auto': 1, 'ring5': 6, 'ring4': 5, 'ring3': 4, 'ring2': 3, 'ring1': 2, 'ring10': 11, 'ring6': 7.
                 concentratorPortOperInsert 1.3.6.1.4.1.33.25.10.1.12 integer read-only
This variable reflects the slot ring to which the port is attached. Enumeration: 'notInserted': 1, 'ring9': 10, 'ring8': 9, 'ring7': 8, 'ring6': 7, 'ring5': 6, 'ring4': 5, 'ring3': 4, 'ring2': 3, 'ring1': 2, 'ring10': 11.
                 concentratorPortSpeed 1.3.6.1.4.1.33.25.10.1.13 integer read-only
This variable reflects the measured speed of the port. Enumeration: 'mbs16': 2, 'mbs4': 1.
                 concentratorPortAdminLoopback 1.3.6.1.4.1.33.25.10.1.14 integer read-write
This variable reflects the whether this port will be inserted into a ring or the data loop backed. Enumeration: 'insert': 1, 'loopback': 2.
                 concentratorPortStationType 1.3.6.1.4.1.33.25.10.1.15 integer read-write
This variable reflects the concentrator port type. Enumeration: 'station': 1, 'trunk': 2.
                 concentratorPortAdminTrunkInsert 1.3.6.1.4.1.33.25.10.1.16 integer read-write
This variable is used to control the insertion of trunk ports. When set to 'execute' the trunk port will be inserted into the ring immediately and not wait for the trunk timer to expire. The agent always returns 'ready' for this value. Setting the value to 'ready' has no effect. Enumeration: 'ready': 1, 'execute': 2.
                 concentratorPortSlotRingsAllowed 1.3.6.1.4.1.33.25.10.1.17 octet string read-only
The list of slot rings into which this port may be inserted. The OCTET STRING contains a bit map, with a bit for 'none' (indicating it may be isolated) and one bit for each slot ring, and enough octets for all slot rings. The high order bit of the first octet corresponds to 'none' and each subsequent bit in ascending order corresponds to the slot rings in order beginning with 1.