Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 xChassis 1.3.6.1.4.1.33.16
       xChassisBasic 1.3.6.1.4.1.33.16.1
           basicBase802Address 1.3.6.1.4.1.33.16.1.1 macaddress read-only
Base IEEE 802 global address for the chassis.
           basicSlot 1.3.6.1.4.1.33.16.1.2 integer read-only
Chassis slot number (slotIndex) of the system whose agent is supplying this MIB.
           basicSlotNumber 1.3.6.1.4.1.33.16.1.3 integer read-only
Number of slots in the chassis.
           basicNewBase802Address 1.3.6.1.4.1.33.16.1.4 macaddress read-write
New base IEEE 802 global address for the chassis. Must be set in conjunction with featType 'changeEthernetAddress' and featKey from the ITouch System MIB.
       xSegment 1.3.6.1.4.1.33.16.2
           segmentTable 1.3.6.1.4.1.33.16.2.1 no-access
A list of segment entries, one for each segment of each type on the chassis.
               segmentEntry 1.3.6.1.4.1.33.16.2.1.1 no-access
Values for a chassis segment.
                   segmentType 1.3.6.1.4.1.33.16.2.1.1.1 networktype read-only
The segment type.
                   segmentIndex 1.3.6.1.4.1.33.16.2.1.1.2 letter read-only
An index value that uniquely identifies a segment.
       xPort 1.3.6.1.4.1.33.16.3
           portIOCardType 1.3.6.1.4.1.33.16.3.1 iotype read-only
The hardware type of the I/O card in this slot.
           portIOCardSerialNumber 1.3.6.1.4.1.33.16.3.2 serialnumber read-only
The ITouch serial number of the I/O card in this slot.
           portIOCardOperStatus 1.3.6.1.4.1.33.16.3.3 integer read-only
Status of the I/O card relative to the function card in this slot. Enumeration: 'unknown': 1, 'good': 3, 'mismatch': 2.
           portTable 1.3.6.1.4.1.33.16.3.4 no-access
A list of port entries, one for each port of each type on the slots I/O card.
               portEntry 1.3.6.1.4.1.33.16.3.4.1 no-access
Values for an I/O card port.
                   portType 1.3.6.1.4.1.33.16.3.4.1.1 networktype read-only
The port type.
                   portIndex 1.3.6.1.4.1.33.16.3.4.1.2 integer read-only
An index value that uniquely identifies a port.
       xController 1.3.6.1.4.1.33.16.4
           controllerTable 1.3.6.1.4.1.33.16.4.1 no-access
A list of controller entries, one for each controller of each type on the local system.
               controllerEntry 1.3.6.1.4.1.33.16.4.1.1 no-access
Values for a controller.
                   controllerType 1.3.6.1.4.1.33.16.4.1.1.1 networktype read-only
The controller type.
                   controllerIndex 1.3.6.1.4.1.33.16.4.1.1.2 integer read-only
An index value that uniquely identifies a controller.
                   controllerNetwork 1.3.6.1.4.1.33.16.4.1.1.3 object identifier read-write
The instance identifier of the first object in the conceptual row entry for the segment, port, or controller this controller is to use, that is, segmentType, portType or controllerType.
       xInterface 1.3.6.1.4.1.33.16.5
           interfaceTable 1.3.6.1.4.1.33.16.5.1 no-access
A list of interface entries, corresponding to the MIB II Interface group. These are directly equivalent to hardware network controllers, and must be the lowest numbered interfaces on the system.
               interfaceEntry 1.3.6.1.4.1.33.16.5.1.1 no-access
Values for an interface.
                   interfaceIndex 1.3.6.1.4.1.33.16.5.1.1.1 integer read-only
An index value that uniquely identifies an interface. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
                   interfaceNetwork 1.3.6.1.4.1.33.16.5.1.1.2 object identifier read-write
The instance identifier of the first object in the conceptual row entry for the segment, port, or controller this interface is to use, that is, segmentType, portType, or controllerType.
       xSlotBootControl 1.3.6.1.4.1.33.16.6
           slotBootControlTable 1.3.6.1.4.1.33.16.6.1 no-access
A list of slot boot control entries.
               slotBootControlEntry 1.3.6.1.4.1.33.16.6.1.1 no-access
Values for a chassis slot.
                   slotBootControlSlot 1.3.6.1.4.1.33.16.6.1.1.1 integer read-only
An index value that uniquely identifies a slot, defined the same as slotIndex.
                   slotBootControlIndex 1.3.6.1.4.1.33.16.6.1.1.2 integer read-only
An index value that uniquely identifies a boot control entry, from 1 to the number of entries for the slot.
                   slotBootControlStatus 1.3.6.1.4.1.33.16.6.1.1.3 integer read-write
The status of the entry. Set to 'disabled' to disable the entry. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlController 1.3.6.1.4.1.33.16.6.1.1.4 object identifier read-write
The instance identifier of the first object in the conceptual row entry for the controller this entry selects for bootstrap operation, that is, controllerType. This entry must be compatible with slotBootControlNetwork, including being of the same network type. The value 0.0 indicates default action.
                   slotBootControlNetwork 1.3.6.1.4.1.33.16.6.1.1.5 object identifier read-write
The instance identifier of the first object in the conceptual row entry for the segment or port this entry selects for bootstrap operation, that is, segmentType or portType. This entry must be compatible with slotBootControlController, including being of the same network type. The value 0.0 indicates default action.
                   slotBootControlMopFile 1.3.6.1.4.1.33.16.6.1.1.6 displaystring read-write
The software file name to request for down-line load of the server via MOP or XMOP.
                   slotBootControlInternetFile 1.3.6.1.4.1.33.16.6.1.1.7 displaystring read-write
The filename to request when loading an image via TFTP.
                   slotBootControlInternetAddress 1.3.6.1.4.1.33.16.6.1.1.8 ipaddress read-write
The internet address of the system is to use for itself when loading via TFTP. The value 0.0.0.0 indicates default action.
                   slotBootControlInternetServer 1.3.6.1.4.1.33.16.6.1.1.9 ipaddress read-write
The internet address of the server to use when loading an image via TFTP. The value 0.0.0.0 indicates default action.
                   slotBootControlInternetGateway 1.3.6.1.4.1.33.16.6.1.1.10 ipaddress read-write
The internet address of the gateway to use when loading an image via TFTP. The value 0.0.0.0 indicates default action.
                   slotBootControlInternetDelimiter 1.3.6.1.4.1.33.16.6.1.1.11 displaystring read-write
The character separating the load file directory name from the file name.
           slotBootControlFlagTable 1.3.6.1.4.1.33.16.6.2 no-access
A list of slot boot control source flag entries.
               slotBootControlFlagEntry 1.3.6.1.4.1.33.16.6.2.1 no-access
Values for a boot control flag.
                   slotBootControlFlagLoadBootpTftp 1.3.6.1.4.1.33.16.6.2.1.1 integer read-write
Control for performing load over BOOTP/TFTP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagParamBootpTftp 1.3.6.1.4.1.33.16.6.2.1.2 integer read-write
Control for performing parameter load over BOOTP/TFTP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagDumpBootpTftp 1.3.6.1.4.1.33.16.6.2.1.3 integer read-write
Control for performing dump over BOOTP/TFTP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagLoadTftpDirect 1.3.6.1.4.1.33.16.6.2.1.4 integer read-write
Control for performing load over direct TFTP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagParamTftpDirect 1.3.6.1.4.1.33.16.6.2.1.5 integer read-write
Control for performing parameter load over direct TFTP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagDumpTftpDirect 1.3.6.1.4.1.33.16.6.2.1.6 integer read-write
Control for performing dump over direct TFTP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagLoadLocal 1.3.6.1.4.1.33.16.6.2.1.7 integer read-write
Control for performing load from a local device. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagParamLocal 1.3.6.1.4.1.33.16.6.2.1.8 integer read-write
Control for performing parameter load from a local device. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagDumpLocal 1.3.6.1.4.1.33.16.6.2.1.9 integer read-write
Control for performing dump from a local device. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagLoadMop 1.3.6.1.4.1.33.16.6.2.1.10 integer read-write
Control for performing load over Digital's MOP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagParamMop 1.3.6.1.4.1.33.16.6.2.1.11 integer read-write
Control for performing parameter load over Digital's MOP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagDumpMop 1.3.6.1.4.1.33.16.6.2.1.12 integer read-write
Control for performing dump over Digital's MOP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagLoadXmop 1.3.6.1.4.1.33.16.6.2.1.13 integer read-write
Control for performing load over ITouch extended MOP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagParamXmop 1.3.6.1.4.1.33.16.6.2.1.14 integer read-write
Control for performing parameter load over ITouch extended MOP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagDumpXmop 1.3.6.1.4.1.33.16.6.2.1.15 integer read-write
Control for performing dump over ITouch extended MOP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagLoadRarpTftp 1.3.6.1.4.1.33.16.6.2.1.16 integer read-write
Control for performing load over RARP/TFTP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagParamRarpTftp 1.3.6.1.4.1.33.16.6.2.1.17 integer read-write
Control for performing parameter load over RARP/TFTP. Enumeration: 'disabled': 1, 'enabled': 2.
                   slotBootControlFlagDumpRarpTftp 1.3.6.1.4.1.33.16.6.2.1.18 integer read-write
Control for performing dump over RARP/TFTP. Enumeration: 'disabled': 1, 'enabled': 2.
           slotBootControlStorageTable 1.3.6.1.4.1.33.16.6.3 no-access
A list of slot boot control Storage entries.
               slotBootControlStorageEntry 1.3.6.1.4.1.33.16.6.3.1 no-access
Values for a chassis slot.
                   slotBootControlStorageClientSlot 1.3.6.1.4.1.33.16.6.3.1.1 integer read-only
An index value that uniquely identifies a slot, defined the same as slotIndex.
                   slotBootControlStorageServerSlot 1.3.6.1.4.1.33.16.6.3.1.2 integer read-only
An index value that uniquely identifies the slot in which the Storage record resides, with the same values as slotIndex.
                   slotBootControlStorageStatus 1.3.6.1.4.1.33.16.6.3.1.3 integer read-only
The status of the entry. Enumeration: 'failed': 2, 'notpresent': 4, 'ok': 3, 'present': 1.
                   slotBootControlStorageFailures 1.3.6.1.4.1.33.16.6.3.1.4 counter read-only
The number of times a read from or write to a given Storage location failed
       xSlot 1.3.6.1.4.1.33.16.7
           slotTable 1.3.6.1.4.1.33.16.7.1 no-access
A list of slot entries.
               slotEntry 1.3.6.1.4.1.33.16.7.1.1 no-access
Values for a chassis slot.
                   slotIndex 1.3.6.1.4.1.33.16.7.1.1.1 integer read-only
An index value that uniquely identifies a slot, in the range 0 to basicSlotNumber, where the value 0 indicates the same slot as basicSlot. As the objects found at instance zero are duplicates, that instance does not appear in responses a get-next, that is, the lowest numbered slotIndex returned by get-next is 1.
                   slotAdminAction 1.3.6.1.4.1.33.16.7.1.1.2 integer read-write
Control to cause reset of the system in a slot. When read, the value is always 'ready'. Setting to 'reset' or 'resetHold' causes a single attempt to take that action, but does not ensure transition to any particular value of slotOperStatus. Enumeration: 'ready': 1, 'reset': 2, 'resetHold': 3.
                   slotOperStatus 1.3.6.1.4.1.33.16.7.1.1.3 integer read-only
Relative to the chassis, the current operating status of the system in the slot. Enumeration: 'unknown': 68, 'invalidConfigStorage': 14, 'paramRequested': 5, 'maxserverCard': 13, 'selfTest': 65, 'notApplicable': 69, 'dumping': 4, 'resetHold': 64, 'paramLoading': 6, 'notResponding': 66, 'broken': 67, 'running': 7, 'loading': 2, 'attended': 9, 'initializing': 8, 'securityLockdown': 15, 'loadRequested': 1, 'internal10': 10, 'internal11': 11, 'dumpRequested': 3, 'inhibited': 12.
                   slotSecondsSinceReset 1.3.6.1.4.1.33.16.7.1.1.4 gauge read-only
The number of seconds since the system in the slot was last reset by hardware or software.
                   slotHardwareType 1.3.6.1.4.1.33.16.7.1.1.5 hardwaretype read-only
The type of hardware in the slot.
                   slotHardwareSerialNumber 1.3.6.1.4.1.33.16.7.1.1.6 serialnumber read-only
The ITouch serial number of the function card hardware in this slot.
                   slotHardwareRevision 1.3.6.1.4.1.33.16.7.1.1.7 integer read-only
This revision level of the function card hardware in the slot.
                   slotIOCardType 1.3.6.1.4.1.33.16.7.1.1.8 iotype read-only
The hardware type of the I/O card in this slot.
                   slotIOCardSerialNumber 1.3.6.1.4.1.33.16.7.1.1.9 serialnumber read-only
The ITouch serial number of the I/O card in this slot.
                   slotIOCardOperStatus 1.3.6.1.4.1.33.16.7.1.1.10 integer read-only
Status of the I/O card relative to the function card in this slot. Enumeration: 'unknown': 1, 'good': 3, 'mismatch': 2, 'notApplicable': 4.
                   slotBootstrapFirmwareRevision 1.3.6.1.4.1.33.16.7.1.1.11 integer read-only
The firmware revision level of the bootstrap ROM installed in the system in the slot.
                   slotElementalFirmwareRevision 1.3.6.1.4.1.33.16.7.1.1.12 integer read-only
The firmware revision level of the minimal function ROM (management bus microprocessor) installed in the system in the slot.
                   slotMemorySize 1.3.6.1.4.1.33.16.7.1.1.13 integer read-only
The number of bytes of memory installed in the system in the slot.
                   slotLedNumber 1.3.6.1.4.1.33.16.7.1.1.14 gauge read-only
The number of LEDs on the system in the slot. A value of 0 indicates none, unknown, or status not readable.
                   slotLedStatus 1.3.6.1.4.1.33.16.7.1.1.15 octet string read-only
The status of the LEDs displayed on the front and back of the system in the slot. The first bit is the high-order bit of the first byte of the value, proceeding to the low-order bit, then to then next byte. On the system hardware, the first LED is at the top, left, front, proceeding left to right, top to bottom, and front to back.
                   slotBase802Address 1.3.6.1.4.1.33.16.7.1.1.16 macaddress read-only
Base IEEE 802 global address for the slot.
                   slotIpAddress 1.3.6.1.4.1.33.16.7.1.1.17 ipaddress read-only
An internet address to which the system in this slot might respond. May be one of many.
                   slotPlus5Status 1.3.6.1.4.1.33.16.7.1.1.18 integer read-only
Status of the +5 volt power to the slot. Enumeration: 'unknown': 1, 'good': 3, 'broken': 2.
                   slotPlus12Status 1.3.6.1.4.1.33.16.7.1.1.19 integer read-only
Status of the +12 volt power to the slot. Enumeration: 'unknown': 1, 'good': 3, 'broken': 2.
                   slotMinus12Status 1.3.6.1.4.1.33.16.7.1.1.20 integer read-only
Status of the -12 volt power to the slot. Enumeration: 'unknown': 1, 'good': 3, 'broken': 2.
                   slotPlus5Watts 1.3.6.1.4.1.33.16.7.1.1.21 gauge read-only
Tenths of watts of +5 volt power currently drawn by the slot.
                   slotPlus12Watts 1.3.6.1.4.1.33.16.7.1.1.22 gauge read-only
Tenths of watts of +12 volt power currently drawn by the slot.
                   slotMinus12Watts 1.3.6.1.4.1.33.16.7.1.1.23 gauge read-only
Tenths of watts of -12 volt power currently drawn by the slot.
                   slotIOCardHardwareVersion 1.3.6.1.4.1.33.16.7.1.1.24 integer read-only
Version number of I/O card in the slot.
                   slotRestoreNVS 1.3.6.1.4.1.33.16.7.1.1.25 integer read-write
Setting to 'execute' causes the non-volatile parameter storage to be restored from an installed memory card. Setting to 'ready' has no effect. Enumeration: 'ready': 1, 'execute': 2.
                   slotDefaultNVS 1.3.6.1.4.1.33.16.7.1.1.26 integer read-write
Setting to 'execute' causes non-volatile stored parameters to be reset to factory defaults. Setting to 'ready' has no effect. Enumeration: 'ready': 1, 'execute': 2.
           slotBootTable 1.3.6.1.4.1.33.16.7.2 no-access
A list of slot bootstrap status entries. A given slot has an entry in this table only when slotOperStatus is one of: loadRequested, loading, dumpRequested, dumping, paramRequested, paramLoading
               slotBootEntry 1.3.6.1.4.1.33.16.7.2.1 no-access
Bootstrap status values for a chassis slot.
                   slotBootIndex 1.3.6.1.4.1.33.16.7.2.1.1 integer read-only
An index value that uniquely identifies a slot, defined the same as slotIndex.
                   slotBootIfIndex 1.3.6.1.4.1.33.16.7.2.1.2 integer read-only
An index value that uniquely identifies the interface in use for bootstrap functions. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
                   slotBootNetwork 1.3.6.1.4.1.33.16.7.2.1.3 object identifier read-only
The instance identifier of the first object in the conceptual row entry for the segment or port this interface is using, that is, segmentType or portType.
                   slotBootProtocol 1.3.6.1.4.1.33.16.7.2.1.4 integer read-only
The protocol in use for bootstrap operation. Enumeration: 'managementBus': 9, 'unknown': 2, 'mop': 3, 'bootpTftp': 6, 'other': 1, 'xmop': 4, 'tftp': 7, 'rarpTftp': 5, 'local': 8.
                   slotBoot802Address 1.3.6.1.4.1.33.16.7.2.1.5 macaddress read-only
IEEE 802 global address in use for bootstrap operation.
                   slotBootAddressType 1.3.6.1.4.1.33.16.7.2.1.6 addresstype read-only
The type of network address contained in slotBootAddress.
                   slotBootAddress 1.3.6.1.4.1.33.16.7.2.1.7 octet string read-only
The network address the system in the slot is using to identify itself for bootstrap operation.
                   slotBootServerAddressType 1.3.6.1.4.1.33.16.7.2.1.8 addresstype read-only
The type of network address contained in slotBootServerAddress.
                   slotBootServerAddress 1.3.6.1.4.1.33.16.7.2.1.9 octet string read-only
The network address of the system supplying bootstrap services to the system in the slot.
                   slotBootGatewayAddress 1.3.6.1.4.1.33.16.7.2.1.10 ipaddress read-only
The internet address of the router in use for bootstrap operation.
                   slotBootFileName 1.3.6.1.4.1.33.16.7.2.1.11 displaystring read-only
The full name of the file in use for bootstrap operation.
                   slotBootBlockNumber 1.3.6.1.4.1.33.16.7.2.1.12 gauge read-only
The current block number being transferred for bootstrap operation, zero if unknown or not applicable.
                   slotBootCrashCode 1.3.6.1.4.1.33.16.7.2.1.13 octet string read-only
If slotOperStatus is dumpRequested or dumping, a code number to identify the crash reason; otherwise zero length.
           slotControllerTable 1.3.6.1.4.1.33.16.7.3 no-access
A list of controller entries, one for each controller of each type in each slot.
               slotControllerEntry 1.3.6.1.4.1.33.16.7.3.1 no-access
Values for a controller.
                   slotControllerType 1.3.6.1.4.1.33.16.7.3.1.1 networktype read-only
The controller type.
                   slotControllerIndex 1.3.6.1.4.1.33.16.7.3.1.2 integer read-only
An index value that uniquely identifies a controller.
                   slotControllerNetwork 1.3.6.1.4.1.33.16.7.3.1.3 object identifier read-only
The instance identifier of the first object in the conceptual row entry for the segment or port this controller is to use, that is, segmentType or portType.
       xPowerSupply 1.3.6.1.4.1.33.16.8
           powerSupplyTable 1.3.6.1.4.1.33.16.8.1 no-access
A list of power supply entries.
               powerSupplyEntry 1.3.6.1.4.1.33.16.8.1.1 no-access
Values for a chassis power supply.
                   powerSupplyIndex 1.3.6.1.4.1.33.16.8.1.1.1 integer read-only
An index value that uniquely identifies a power supply, in the range 1 to the number of power supply slots in the chassis.
                   powerSupplyAdminAction 1.3.6.1.4.1.33.16.8.1.1.2 integer read-write
Control to cause reset of the power supply. When read, the value is always 'ready'. Setting to 'reset' or 'resetHold' causes a single attempt to take that action, but does not ensure transition to any particular value of powerSupplyRedundancyStatus. Enumeration: 'ready': 1, 'reset': 2, 'resetHold': 3.
                   powerSupplyFirmwareVersion 1.3.6.1.4.1.33.16.8.1.1.3 integer read-only
Version number of power supply firmware.
                   powerSupplyRedundancyStatus 1.3.6.1.4.1.33.16.8.1.1.4 integer read-only
The current redundancy status of the power supply. Enumeration: 'disabled': 2, 'unknown': 1, 'engaged': 4, 'redundant': 3.
                   powerSupplyPlus5Status 1.3.6.1.4.1.33.16.8.1.1.5 integer read-only
Status of the +5 volt power from the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyPlus12Status 1.3.6.1.4.1.33.16.8.1.1.6 integer read-only
Status of the +12 volt power from the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyMinus12Status 1.3.6.1.4.1.33.16.8.1.1.7 integer read-only
Status of the -12 volt power from the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyThermalWarningStatus 1.3.6.1.4.1.33.16.8.1.1.8 integer read-only
The current thermal warning status of the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyThermalShutdownStatus 1.3.6.1.4.1.33.16.8.1.1.9 integer read-only
The current thermal shutdown status of the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyFanStatus 1.3.6.1.4.1.33.16.8.1.1.10 integer read-only
The current status of the power supply's fan. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyHardwareInhibitStatus 1.3.6.1.4.1.33.16.8.1.1.11 integer read-only
The current status of the power supply's hardware inhibit. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyPlus5History 1.3.6.1.4.1.33.16.8.1.1.12 integer read-only
History of the +5 volt power from the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyPlus12History 1.3.6.1.4.1.33.16.8.1.1.13 integer read-only
History of the +12 volt power from the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyMinus12History 1.3.6.1.4.1.33.16.8.1.1.14 integer read-only
History of the -12 volt power from the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyThermalWarningHistory 1.3.6.1.4.1.33.16.8.1.1.15 integer read-only
The thermal warning history of the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyThermalShutdownHistory 1.3.6.1.4.1.33.16.8.1.1.16 integer read-only
The thermal shutdown history of the power supply. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyFanHistory 1.3.6.1.4.1.33.16.8.1.1.17 integer read-only
The status history of the power supply's fan. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyHardwareInhibitHistory 1.3.6.1.4.1.33.16.8.1.1.18 integer read-only
The status history of the power supply's hardware inhibit. Enumeration: 'unknown': 1, 'good': 2, 'broken': 3.
                   powerSupplyPlus5Volts 1.3.6.1.4.1.33.16.8.1.1.19 gauge read-only
In hundredths, volts of +5 volt power currently provided by the power supply. A value of 0 indicates unknown.
                   powerSupplyPlus12Volts 1.3.6.1.4.1.33.16.8.1.1.20 gauge read-only
In hundredths, volts of +12 volt power currently provided by the power supply. A value of 0 indicates unknown.
                   powerSupplyMinus12Volts 1.3.6.1.4.1.33.16.8.1.1.21 gauge read-only
In hundredths, volts of -12 volt power currently provided by the power supply. A value of 0 indicates unknown.
                   powerSupplyWatts 1.3.6.1.4.1.33.16.8.1.1.22 gauge read-only
Watts of power currently drawn from this power supply. A value of 0 indicates unknown.
                   powerSupplyWattsMax 1.3.6.1.4.1.33.16.8.1.1.23 gauge read-only
Maximum watts of power available from this power supply. A value of 0 indicates unknown.
                   powerSupplyChassisWatts 1.3.6.1.4.1.33.16.8.1.1.24 gauge read-only
Total watts of power currently drawn by the entire chassis. A value of 0 indicates unknown.
                   powerSupplyChassisWattsMax 1.3.6.1.4.1.33.16.8.1.1.25 gauge read-only
Total maximum watts of power available from all the power supplies in the chassis. A value of 0 indicates unknown.
                   powerSupplyHardwareType 1.3.6.1.4.1.33.16.8.1.1.26 integer read-only
The type of power supply. Enumeration: 'other': 1, 'ps130': 2, 'bb190': 3.
       xFirmwareUpdate 1.3.6.1.4.1.33.16.9
           firmwareUpdateTable 1.3.6.1.4.1.33.16.9.1 no-access
Table of descriptive and status information concerning the writing of firmware to a target I/O card.
               firmwareUpdateEntry 1.3.6.1.4.1.33.16.9.1.1 no-access
An entry in the table concerning the writing of firmware to a target I/O card.
                   firmwareUpdateSlotIndex 1.3.6.1.4.1.33.16.9.1.1.1 integer read-only
This variable identifies the slot to which is to be the target of the firmware update.
                   firmwareUpdateDefaultFileName 1.3.6.1.4.1.33.16.9.1.1.2 displaystring read-only
This variable when read will obtain the default file name from the target.
                   firmwareUpdateFileName 1.3.6.1.4.1.33.16.9.1.1.3 displaystring read-write
This variable contains the name of the file to be read from the flash memory card and written to the target.
                   firmwareUpdateStatus 1.3.6.1.4.1.33.16.9.1.1.4 integer read-write
This variable is used to start the update process. The agent always 'ready' for this value. Setting this value to 'execute' causes the agent to write the file specified by firmwareUpdateFileName to be written to the taget. Setting this value to 'execute' when firmwareUpdateFileName has not been written or when firmwareUpdateState is 'writing' causes bad value to be returned. Enumeration: 'ready': 1, 'execute': 2.
                   firmwareUpdateState 1.3.6.1.4.1.33.16.9.1.1.5 integer read-only
This variable indicates the current state of firmware update, 'idle' indicates that firmware update may be initiated, and 'writing' indicates that an update is in process. Enumeration: 'idle': 1, 'writing': 2.
                   firmwareUpdateCompletionStatus 1.3.6.1.4.1.33.16.9.1.1.6 integer read-only
This variable indicates the completion status of the the last firmware update attempt. 'none' indicates that no firmware update has yet been attempted. Enumeration: 'busError': 4, 'none': 1, 'targetError': 6, 'success': 2, 'noTarget': 3, 'badFileName': 5, 'timeout': 7.
                   firmwareUpdateMethod 1.3.6.1.4.1.33.16.9.1.1.7 integer read-write
This variable indicates the method of update of the firmware update attempt. Enumeration: 'local': 2, 'card': 1.