DKSF-201-9-X-X-1: View SNMP OID List / Download MIB

VENDOR: ZAO LIGHT COMMUNICATION


 Home MIB: DKSF-201-9-X-X-1
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 lightcom 1.3.6.1.4.1.25728
             npTrapInfo 1.3.6.1.4.1.25728.90
                   npTrapEmailTo 1.3.6.1.4.1.25728.90.1 displaystring read-only
user-specified e-mail for NetPing Trap Forwarding Service
             netPing2PWR220SMSv3 1.3.6.1.4.1.25728.201
Generic MIB for NetPing remote sensing and control
             npReboot 1.3.6.1.4.1.25728.911
                     npSoftReboot 1.3.6.1.4.1.25728.911.1 integer read-write
Write 1 to reboot device after current operations completition
                     npResetStack 1.3.6.1.4.1.25728.911.2 integer read-write
Write 1 to re-initialize network stack
                     npForcedReboot 1.3.6.1.4.1.25728.911.3 integer read-write
Write 1 to immediate forced reboot
             npGsm 1.3.6.1.4.1.25728.3800
                       npGsmInfo 1.3.6.1.4.1.25728.3800.1
                           npGsmFailed 1.3.6.1.4.1.25728.3800.1.1 integer read-only
Firmware's GSM module status Enumeration: 'failed': 1, 'ok': 0, 'fatalError': 2.
                           npGsmRegistration 1.3.6.1.4.1.25728.3800.1.2 integer read-only
Status of modem registration in GSM network (AT+CREG? result) Enumeration: 'infoUpdate': 255, 'unknown': 4, 'searching': 2, 'denied': 3, 'impossible': 0, 'roaming': 5, 'homeNetwork': 1.
                           npGsmStrength 1.3.6.1.4.1.25728.3800.1.3 integer read-only
GSM signal strength. 0..31 = 0..100%, 99 = unknown or n/a, 255 = updating info
                       npGsmTraps 1.3.6.1.4.1.25728.3800.2
                           npGsmTrapPrefix 1.3.6.1.4.1.25728.3800.2.0
                               npGsmTrap 1.3.6.1.4.1.25728.3800.2.0.1
GSM modem or SMS firmware problems
             npRelay 1.3.6.1.4.1.25728.5500
                       npRelayTable 1.3.6.1.4.1.25728.5500.5 no-access
Watchdog and outlet/relay control table
                           npRelayEntry 1.3.6.1.4.1.25728.5500.5.1 no-access
Relay/outlet table row
                               npRelayN 1.3.6.1.4.1.25728.5500.5.1.1 integer read-only
The N of output relay
                               npRelayMode 1.3.6.1.4.1.25728.5500.5.1.2 integer read-write
Control of relay: 0 - manual off 1 - manual on 2 - watchdog 3 - schedule 4 - both schedule and watchdog (while switched on by schedule) 5 - logic Enumeration: 'on': 1, 'off': 0, 'schedule': 3, 'logic': 5, 'scheduleAndWatchdog': 4, 'watchdog': 2.
                               npRelayStartReset 1.3.6.1.4.1.25728.5500.5.1.3 integer read-write
Write 1 to start reset (switch relay off for some time)
                               npRelayMemo 1.3.6.1.4.1.25728.5500.5.1.6 displaystring read-only
Relay memo
                               npRelayFlip 1.3.6.1.4.1.25728.5500.5.1.14 integer read-only
Write -1 to flip between manual on and manual off states of relay Enumeration: 'flip': -1.
                               npRelayState 1.3.6.1.4.1.25728.5500.5.1.15 integer read-only
Actual relay state at the moment, regardless of source of control. 0 - relay is off 1 - relay is on Enumeration: 'on': 1, 'off': 0.
             npPwr 1.3.6.1.4.1.25728.5800
                       npPwrTable 1.3.6.1.4.1.25728.5800.3 no-access
Watchdog and outlet/relay control table
                           npPwrEntry 1.3.6.1.4.1.25728.5800.3.1 no-access
Watchdog and outlet/relay control table row
                               npPwrChannelN 1.3.6.1.4.1.25728.5800.3.1.1 integer read-only
The id of watchdog/power channel
                               npPwrStartReset 1.3.6.1.4.1.25728.5800.3.1.2 integer read-write
Write 1 to start forced reset On read: 0 - normal operation 1 - reset is active 2 - reboot pause is active or watchdog is inactive
                               npPwrManualMode 1.3.6.1.4.1.25728.5800.3.1.3 integer read-write
Mode of power channel 0 - manual off 1 - manual on 2 - watchdog 3 - schedule 4 - schedule and watchdog 5 - controlled by Logic Enumeration: 'on': 1, 'off': 0, 'schedule': 3, 'logic': 5, 'scheduleAndWatchdog': 4, 'watchdog': 2.
                               npPwrResetsCounter 1.3.6.1.4.1.25728.5800.3.1.4 integer read-write
Counter of watchdog resets Write 0 to clear.
                               npPwrRepeatingResetsCounter 1.3.6.1.4.1.25728.5800.3.1.5 integer read-only
Counter of continous failed watchdog resets
                               npPwrMemo 1.3.6.1.4.1.25728.5800.3.1.6 displaystring read-only
Relay channel memo
                               npPwrRelayFlip 1.3.6.1.4.1.25728.5800.3.1.14 integer read-write
Write -1 to flip between manual on and manual off states of relay Enumeration: 'flip': -1.
                               npPwrRelayState 1.3.6.1.4.1.25728.5800.3.1.15 integer read-only
Actual relay state at the moment, regardless of source of control. 0 - relay is off 1 - relay is on Enumeration: 'on': 1, 'off': 0.
             npIr 1.3.6.1.4.1.25728.7900
                       npIrCtrl 1.3.6.1.4.1.25728.7900.1
                           npIrPlayCmd 1.3.6.1.4.1.25728.7900.1.1 integer read-write
Write IR command number to send IR command
                           npIrReset 1.3.6.1.4.1.25728.7900.1.2 integer read-write
Write 1 to reset IR transiever. After reset, send IR command and check npIrStatus.
                           npIrStatus 1.3.6.1.4.1.25728.7900.1.3 integer read-only
IR transiever status Enumeration: 'busyCaptureWaitingButton': 1, 'busyCaptureWaitingIr': 2, 'ok': 0, 'busyPlayback': 3, 'error': 255.
             npRelHumidity 1.3.6.1.4.1.25728.8400
                       npRelHumSensor 1.3.6.1.4.1.25728.8400.2
                           npRelHumSensorValueH 1.3.6.1.4.1.25728.8400.2.2 integer read-only
Relative humidity value, %
                           npRelHumSensorStatus 1.3.6.1.4.1.25728.8400.2.3 integer read-only
Status of the Rel.Humidity Sensor One 0=Normal, 1=Error or Sensor isn't connected Enumeration: 'ok': 0, 'error': 1.
                           npRelHumSensorValueT 1.3.6.1.4.1.25728.8400.2.4 integer read-only
Sensor temperature, deg.C
                           npRelHumSensorStatusH 1.3.6.1.4.1.25728.8400.2.5 integer read-only
Status of Relative Humiduty Enumeration: 'sensorFailed': 0, 'aboveSafeRange': 3, 'inSafeRange': 2, 'belowSafeRange': 1.
                           npRelHumSafeRangeHigh 1.3.6.1.4.1.25728.8400.2.7 integer read-only
Relative Humidity safe range, top margin, %RH
                           npRelHumSafeRangeLow 1.3.6.1.4.1.25728.8400.2.8 integer read-only
Relative Humidity safe range, bottom margin, %RH
                           npRelHumSensorValueT100 1.3.6.1.4.1.25728.8400.2.9 integer32 read-only
Sensor temperature, deg.C * 100 (fixed point two decimal places) Used to get access to the fractional part of T value
                       npRelHumTraps 1.3.6.1.4.1.25728.8400.9
                           npRelHumTrapPrefix 1.3.6.1.4.1.25728.8400.9.0
                               npRelHumTrap 1.3.6.1.4.1.25728.8400.9.0.1
Status of Relative Humidity RH sensor has changed!
             npThermo 1.3.6.1.4.1.25728.8800
                       npThermoTable 1.3.6.1.4.1.25728.8800.1 no-access
Thermo Sensors Table
                           npThermoEntry 1.3.6.1.4.1.25728.8800.1.1 no-access
Thermo Sensors Table Row
                               npThermoSensorN 1.3.6.1.4.1.25728.8800.1.1.1 integer read-only
The id of temperature sensor, 1 to 8
                               npThermoValue 1.3.6.1.4.1.25728.8800.1.1.2 integer read-only
Temperature, deg.C
                               npThermoStatus 1.3.6.1.4.1.25728.8800.1.1.3 integer read-only
Temperature status (0=fault, 1=underheat, 2=normal, 3=overheat) Enumeration: 'high': 3, 'failed': 0, 'low': 1, 'norm': 2.
                               npThermoLow 1.3.6.1.4.1.25728.8800.1.1.4 integer read-only
Bottom margin of normal temperature range, deg.C
                               npThermoHigh 1.3.6.1.4.1.25728.8800.1.1.5 integer read-only
Top margin of normal temperature range, deg.C
                               npThermoMemo 1.3.6.1.4.1.25728.8800.1.1.6 displaystring read-only
T channel memo
                       npThermoTraps 1.3.6.1.4.1.25728.8800.2
                           npThermoTrapPrefix 1.3.6.1.4.1.25728.8800.2.0
                               npThermoTrap 1.3.6.1.4.1.25728.8800.2.0.1
Status of Thermo sensor is changed (crossing of normal temp. range)
                           npThermoTrapSensorN 1.3.6.1.4.1.25728.8800.2.1 integer read-only
The id of temperature sensor, 1 to 8
                           npThermoTrapValue 1.3.6.1.4.1.25728.8800.2.2 integer read-only
Temperature, deg.C
                           npThermoTrapStatus 1.3.6.1.4.1.25728.8800.2.3 integer read-only
Temperature status (0=fault, 1=underheat, 2=normal, 3=overheat) Enumeration: 'high': 3, 'failed': 0, 'low': 1, 'norm': 2.
                           npThermoTrapLow 1.3.6.1.4.1.25728.8800.2.4 integer read-only
Bottom margin of normal temperature range, deg.C
                           npThermoTrapHigh 1.3.6.1.4.1.25728.8800.2.5 integer read-only
Top margin of normal temperature range, deg.C
                           npThermoTrapMemo 1.3.6.1.4.1.25728.8800.2.6 displaystring read-only
T channel memo
             npIo 1.3.6.1.4.1.25728.8900
                       npIoTable 1.3.6.1.4.1.25728.8900.1 no-access
Digital Input/output Table
                           npIoEntry 1.3.6.1.4.1.25728.8900.1.1 no-access
Digital Input/output Table Row
                               npIoLineN 1.3.6.1.4.1.25728.8900.1.1.1 integer read-only
Number of IO line, from 1 to max supported
                               npIoLevelIn 1.3.6.1.4.1.25728.8900.1.1.2 integer read-only
Input level, 0 or 1
                               npIoLevelOut 1.3.6.1.4.1.25728.8900.1.1.3 integer read-write
Output level Enumeration: 'high': 1, 'flip': -1, 'low': 0.
                               npIoMemo 1.3.6.1.4.1.25728.8900.1.1.6 displaystring read-only
IO line memo
                               npIoPulseCounter 1.3.6.1.4.1.25728.8900.1.1.9 counter32 read-write
Pulse Counter on IO input line (counts positive fronts) Write 0 to reset.
                               npIoSinglePulseDuration 1.3.6.1.4.1.25728.8900.1.1.12 integer read-write
Set duration of single pulse on IO output line, 100ms to 25500ms, min. step is 100ms
                               npIoSinglePulseStart 1.3.6.1.4.1.25728.8900.1.1.13 integer read-write
Write 1 to start single pulse on IO output. Output will be inverted for time, specified by npIoSinglePulseDuration
                       npIoTraps 1.3.6.1.4.1.25728.8900.2
                           npIoTrapPrefix 1.3.6.1.4.1.25728.8900.2.0
                               npIoTrap 1.3.6.1.4.1.25728.8900.2.0.1
Input state of IO line is changed
                           npIoTrapLineN 1.3.6.1.4.1.25728.8900.2.1 integer read-only
Trap data, Number of IO line
                           npIoTrapLevelIn 1.3.6.1.4.1.25728.8900.2.2 integer read-only
Trap data, new Input level, 0 or 1
                           npIoTrapMemo 1.3.6.1.4.1.25728.8900.2.6 displaystring read-only
Trap data, IO line memo