Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 cpqWcrm 1.3.6.1.4.1.232.167
         cpqWcrmMibRev 1.3.6.1.4.1.232.167.1
             cpqWcrmMibMajRev 1.3.6.1.4.1.232.167.1.1 integer read-only
The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information, correct interpretation of data may require a MIB document with the same major revision level.
             cpqWcrmMibMinRev 1.3.6.1.4.1.232.167.1.2 integer read-only
The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
             cpqWcrmMibCondition 1.3.6.1.4.1.232.167.1.3 integer read-only
The overall condition (status) of the system represented by this MIB. (2) OK (3) a minor problem, warning condition (yellow LED on Environmental Controller) (4) a major problem (red LED on Environmental Controller) (5) configuration of sensor units changed or unit detected (red/yellow/green LED on Environmental Controller) Enumeration: 'failed': 4, 'degraded': 3, 'other': 1, 'ok': 2, 'configChanged': 5.
         cpqWcrmStatus 1.3.6.1.4.1.232.167.2
             cpqWcrmStatusDeviceEnvironmentalController 1.3.6.1.4.1.232.167.2.1 integer read-only
General Status of Environmental Controller unit itself (1) failed (2) OK Enumeration: 'failed': 1, 'ok': 2.
             cpqWcrmUnitsConnected 1.3.6.1.4.1.232.167.2.2 integer read-only
Number of sensor units connected to the Environmental Controller, Port 1 to 2
             cpqWcrmStatusSensorInternal 1.3.6.1.4.1.232.167.2.3
                 cpqWcrmInternalTypeOfDevice 1.3.6.1.4.1.232.167.2.3.1 integer read-only
Type of sensor unit connected to port 1 Enumeration: 'unitIO': 3, 'unitWcrm': 2, 'notAvail': 1.
                 cpqWcrmInternalText 1.3.6.1.4.1.232.167.2.3.2 displaystring read-write
Descriptional text for sensor unit connected to port 1
                 cpqWcrmInternalSerial 1.3.6.1.4.1.232.167.2.3.3 integer read-only
Serialnumber of sensor unit connected to port 1
                 cpqWcrmInternalStatus 1.3.6.1.4.1.232.167.2.3.4 integer read-only
General Status sensor unit connected to port 1 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) reset from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low Enumeration: 'reset': 4, 'ok': 1, 'lowPower': 8, 'changed': 3, 'detected': 6, 'notAvail': 7, 'timeout': 5, 'error': 2.
                 cpqWcrmStatusInternalSensors 1.3.6.1.4.1.232.167.2.3.5
                     cpqWcrmInternalNumberOfSensors 1.3.6.1.4.1.232.167.2.3.5.1 integer read-only
Number of sensors connected to sensor unit 1
                     cpqWcrmInternalSensorTable 1.3.6.1.4.1.232.167.2.3.5.2 no-access
Headline of sensor table
                         cpqWcrmInternalSensorEntry 1.3.6.1.4.1.232.167.2.3.5.2.1 no-access
Entries of sensor table
                             internalSensorIndex 1.3.6.1.4.1.232.167.2.3.5.2.1.1 integer read-only
Index for the list of value entries. Its value ranges between 1 and the value of cpqWcrmInternalNumberOfSensors.
                             internalSensorType 1.3.6.1.4.1.232.167.2.3.5.2.1.2 integer read-only
Type of sensor which is connected to internal sensor to sensor[internalSensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage (OK, NOK) 18: voltage value 19: fan status, from Environmental Controller-FAS-Unit 20: leakage sensor Enumeration: 'motion': 6, 'airFlow': 8, 'temperature': 10, 'vibration': 5, 'current4to20': 11, 'fanOK': 19, 'humidity': 12, 'access': 4, 'failure': 2, 'userNC': 14, 'notAvail': 1, 'voltage': 18, 'smoke': 7, 'leakage': 20, 'overflow': 3, 'type6': 9, 'voltOK': 17, 'userNO': 13.
                             internalSensorText 1.3.6.1.4.1.232.167.2.3.5.2.1.3 displaystring read-write
Descriptional text for each sensor (entry in the table)
                             internalSensorStatus 1.3.6.1.4.1.232.167.2.3.5.2.1.4 integer read-only
Actual status of the sensor Enumeration: 'on': 6, 'ok': 4, 'lost': 2, 'tooHigh': 9, 'changed': 3, 'warning': 7, 'notAvail': 1, 'off': 5, 'tooLow': 8.
                             internalSensorValue 1.3.6.1.4.1.232.167.2.3.5.2.1.5 integer read-only
Value of sensor
                             internalSensorSetHigh 1.3.6.1.4.1.232.167.2.3.5.2.1.6 integer read-write
Value for high setpoint of sensor
                             internalSensorSetLow 1.3.6.1.4.1.232.167.2.3.5.2.1.7 integer read-write
Value for low setpoint of sensor, also used as alarm delay
                             internalSensorSetWarn 1.3.6.1.4.1.232.167.2.3.5.2.1.8 integer read-write
Value for warning setpoint of sensor, also used as fan threshold
                 cpqWcrmStatusInternalOutputs 1.3.6.1.4.1.232.167.2.3.6
                     cpqWcrmInternalNumberOfOutputs 1.3.6.1.4.1.232.167.2.3.6.1 integer read-only
Number of outputs available on internal sensor
                     cpqWcrmInternalOutputTable 1.3.6.1.4.1.232.167.2.3.6.2 no-access
Headline of output table
                         cpqWcrmInternalOutputEntry 1.3.6.1.4.1.232.167.2.3.6.2.1 no-access
Entries of output table
                             internalOutputIndex 1.3.6.1.4.1.232.167.2.3.6.2.1.1 integer read-only
Index for the list of output entries. Its value ranges between 1 and the value of cpqWcrmInternalNumberOfOutputs.
                             internalOutputType 1.3.6.1.4.1.232.167.2.3.6.2.1.2 integer read-only
Type of output which is connected to internal sensor to output[internalOutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 6, universal relay output 5: output type 8, power output Enumeration: 'failure': 2, 'overflow': 3, 'notAvail': 1, 'universalOut': 4, 'powerOut': 5.
                             internalOutputText 1.3.6.1.4.1.232.167.2.3.6.2.1.3 displaystring read-write
Descriptional text for each output (entry in the table)
                             internalOutputStatus 1.3.6.1.4.1.232.167.2.3.6.2.1.4 integer read-write
Actual status of the output Enumeration: 'on': 6, 'ok': 4, 'setOn': 8, 'lost': 2, 'setOff': 7, 'changed': 3, 'notAvail': 1, 'off': 5.
                             internalOutputValue 1.3.6.1.4.1.232.167.2.3.6.2.1.5 integer read-write
Value for output
                             internalOutputSet 1.3.6.1.4.1.232.167.2.3.6.2.1.6 integer read-write
Command for output Enumeration: 'on': 2, 'unlock': 4, 'off': 1, 'unlockDelay': 5, 'lock': 3.
                             internalOutputConfig 1.3.6.1.4.1.232.167.2.3.6.2.1.7 integer read-write
Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control Enumeration: 'enRemote': 2, 'disRemote': 1.
                             internalOutputDelay 1.3.6.1.4.1.232.167.2.3.6.2.1.8 integer read-write
Unsigned Value for delay, after this time the output will fall into the previous state
                             internalOutputTimeoutAction 1.3.6.1.4.1.232.167.2.3.6.2.1.9 integer read-write
State for output if timeout (RS422) occurs Enumeration: 'on': 3, 'off': 2, 'stay': 1.
                 cpqWcrmStatusInternalMsg 1.3.6.1.4.1.232.167.2.3.7
                     cpqWcrmInternalNumberOfMsgs 1.3.6.1.4.1.232.167.2.3.7.1 integer read-only
Number of messages that can be created with internal sensor
                     cpqWcrmInternalMsgTable 1.3.6.1.4.1.232.167.2.3.7.2 no-access
Headline of message table
                         cpqWcrmInternalMsgEntry 1.3.6.1.4.1.232.167.2.3.7.2.1 no-access
Entries of message table
                             internalMsgIndex 1.3.6.1.4.1.232.167.2.3.7.2.1.1 integer read-only
Index for the list of message entries. Its value ranges between 1 and the value of cpqWcrmInternalNumberOfMsgs.
                             internalMsgText 1.3.6.1.4.1.232.167.2.3.7.2.1.2 displaystring read-write
Descriptional text for each message (entry in the table)
                             internalMsgStatus 1.3.6.1.4.1.232.167.2.3.7.2.1.3 integer read-only
Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF Enumeration: 'setOff': 9, 'configChanged': 2, 'ok': 4, 'setOn': 10, 'tooHigh': 8, 'alarm': 5, 'warning': 6, 'notAvail': 1, 'error': 3, 'tooLow': 7.
                             internalMsgRelay 1.3.6.1.4.1.232.167.2.3.7.2.1.4 integer read-write
Setup of Alarm relay for this message/alarm 1: no switching of alarm relay 2: switching of alarm relay Enumeration: 'enable': 2, 'disable': 1.
                             internalMsgBeeper 1.3.6.1.4.1.232.167.2.3.7.2.1.5 integer read-write
Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm Enumeration: 'enable': 2, 'disable': 1.
                             internalMsgTrap1 1.3.6.1.4.1.232.167.2.3.7.2.1.6 integer read-write
Trap receiver 1 activated Enumeration: 'enable': 2, 'disable': 1.
                             internalMsgTrap2 1.3.6.1.4.1.232.167.2.3.7.2.1.7 integer read-write
Trap receiver 2 activated Enumeration: 'enable': 2, 'disable': 1.
                             internalMsgTrap3 1.3.6.1.4.1.232.167.2.3.7.2.1.8 integer read-write
Trap receiver 3 activated Enumeration: 'enable': 2, 'disable': 1.
                             internalMsgTrap4 1.3.6.1.4.1.232.167.2.3.7.2.1.9 integer read-write
Trap receiver 4 and Event Logging activated Enumeration: 'enable': 2, 'disable': 1.
                             internalMsgReset 1.3.6.1.4.1.232.167.2.3.7.2.1.10 integer read-write
Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key Enumeration: 'auto': 1, 'manual': 2.
             cpqWcrmStatusSensorWaterCoolUnit 1.3.6.1.4.1.232.167.2.4
                 cpqWcrmWaterCoolUnitTypeOfDevice 1.3.6.1.4.1.232.167.2.4.1 integer read-only
Type of sensor unit connected to port 2 Enumeration: 'unitIO': 3, 'unitWcrm': 2, 'notAvail': 1.
                 cpqWcrmWaterCoolUnitText 1.3.6.1.4.1.232.167.2.4.2 displaystring read-write
Descriptional text for sensor unit connected to port 2
                 cpqWcrmWaterCoolUnitSerial 1.3.6.1.4.1.232.167.2.4.3 integer read-only
Serialnumber of sensor unit connected to port 2
                 cpqWcrmWaterCoolUnitStatus 1.3.6.1.4.1.232.167.2.4.4 integer read-only
General Status sensor unit connected to port 2 (1) OK (2) error (3) configuration of sensor unit has changed, confirmation required (4) reset from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required (6) sensor unit detected, needs to be confirmed (8) supply voltage is too low Enumeration: 'reset': 4, 'ok': 1, 'lowPower': 8, 'changed': 3, 'detected': 6, 'notAvail': 7, 'timeout': 5, 'error': 2.
                 cpqWcrmStatusWaterCoolUnitSensors 1.3.6.1.4.1.232.167.2.4.5
                     cpqWcrmWaterCoolUnitNumberOfSensors 1.3.6.1.4.1.232.167.2.4.5.1 integer read-only
Number of sensors connected to water cool unit
                     cpqWcrmWaterCoolUnitSensorTable 1.3.6.1.4.1.232.167.2.4.5.2 no-access
Headline of sensor table
                         cpqWcrmWaterCoolUnitSensorEntry 1.3.6.1.4.1.232.167.2.4.5.2.1 no-access
Entries of sensor table
                             waterCoolUnitSensorIndex 1.3.6.1.4.1.232.167.2.4.5.2.1.1 integer read-only
Index for the list of value entries. Its value ranges between 1 and the value of cpqWcrmWaterCoolUnitNumberOfSensors.
                             waterCoolUnitSensorType 1.3.6.1.4.1.232.167.2.4.5.2.1.2 integer read-only
Type of sensor which is connected to internal sensor to sensor[internalSensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: average temperature of air inlet to rack, average or max/min from each HEX 5: average temperature of air outlet from rack, average or max/min from each HEX 6: heatflow sensor 7: alarm: Bit 0: Leakage Bit 1: IIC Failure 8: warning: Bit 0..2: Fan Tach 1..3 Bit 3,4: Temp. sensor HEX1 In,Out Bit 5,6: Temp. sensor HEX2 In,Out Bit 7,8: Temp. sensor HEX3 In,Out Bit 9: Air temp. sensor Bit 10..12: IIC failure, HEX1..3 Bit 13: Waterflow low Bit 14,15: Watertemp. In,Out Bit 16: Waterflow sensor fail. Bit 17: Magnetic valve fail. Bit 18: Leakdetector fail. Bit 19: Uneven heat load Bit 20: Condensation Pump Cycles > Max Bit 21: Condensation Pump Running Time > Max 9: rpm speed of Fan1 10: rpm speed of Fan2 11: rpm speed of Fan3 12: fanSpeed setpoint, calculated from average temperatures 13: temperature air inlet to rack, HEX 1 14: temperature air outlet from rack, HEX 1 15: temperature air inlet to rack, HEX 1 16: temperature air outlet from rack, HEX 1 17: temperature air inlet to rack, HEX 1 18: temperature air outlet from rack, HEX 1 19: water temperature In 20: water temperature Out 21: water Flow 22: water valve status: MCS:0: Valve opened, 1: valve closed; MCSS: valve setpoint (%) 23: status: Bit 0..Bit 2: fan module 1..3 available Bit 3: water module available 24: condensation pump number of seconds on counter (last operating time) 25: condensation pump on/off cycle counter 26: rpm speed of Fan4 27: rpm speed of Fan5 28: rpm speed of Fan6 29: status of transfer switch, 1=AC1, 2=AC2, 3=AC1 and AC2 30: water valve actual value (%) Enumeration: 'waterFlow': 21, 'heatFlow': 6, 'warning': 8, 'fanSpeed': 12, 'tempOut2': 16, 'tempOut3': 18, 'tempOut1': 14, 'transfSwitch': 29, 'valve': 22, 'condensateCycles': 25, 'status': 23, 'condensateDuration': 24, 'rpmFan5': 27, 'rpmFan4': 26, 'rpmFan6': 28, 'rpmFan1': 9, 'tempWaterIn': 19, 'rpmFan3': 11, 'rpmFan2': 10, 'failure': 2, 'tempWaterOut': 20, 'tempOut': 5, 'overflow': 3, 'tempIn2': 15, 'tempIn3': 17, 'tempIn1': 13, 'valveActValue': 30, 'tempIn': 4, 'alarm': 7, 'notAvail': 1.
                             waterCoolUnitSensorText 1.3.6.1.4.1.232.167.2.4.5.2.1.3 displaystring read-write
Descriptional text for each sensor (entry in the table)
                             waterCoolUnitSensorStatus 1.3.6.1.4.1.232.167.2.4.5.2.1.4 integer read-only
Actual status of the sensor Enumeration: 'on': 6, 'ok': 4, 'lost': 2, 'tooHigh': 9, 'changed': 3, 'warning': 7, 'notAvail': 1, 'off': 5, 'tooLow': 8.
                             waterCoolUnitSensorValue 1.3.6.1.4.1.232.167.2.4.5.2.1.5 integer read-only
Value of sensor added to traps, msg index also added (waterCoolUnitMsgIndex) If msg index = 1, 5 or 6 This value represents the actual Server Intake Temperature. If msg index = 2: This value represents the bit coded warning condition Bit 0: Top Fan Module Failed Bit 1: Middle Fan Module Failed Bit 2: Bottom Fan Module Failed Bit 3: Top HEX Intake Air Temperature Sensor to Server Failed Bit 4: Top HEX Exhaust Air Temperature Sensor from Server Failed Bit 5: Middle HEX Intake Air Temperature Sensor to Server Failed Bit 6: Middle HEX Exhaust Air Temperature Sensor from Server Failed Bit 7: Bottom HEX Intake Air Temperature Sensor to Server Failed Bit 8: Bottom HEX Exhaust Air Temperature Sensor from Server Failed Bit 9: Air Temperature Sensor Failed Bit 10: Top Fan not installed Bit 11: Middle Fan not installed Bit 12: Bottom Fan not installed Bit 13: Waterflow low Bit 14: Water Unit Temperature Input Out of Range Bit 15: Water Unit Temperature Output Out of Range Bit 16: Waterflow Sensor Value Out of Range Bit 17: Water Valve Failed Bit 18: Leakdetector Failed Bit 19: Heat Load Warning Bit 20: The Condensation Pump has exceeded the max. number of cycles Bit 21: The Condensation Pump has exceeded the max. Running Time If msg index = 3: This value represents the bit coded alarm condition Bit 0: Leakage Detected Bit 1: Comm. Failure IIC
                             waterCoolUnitSensorSetHigh 1.3.6.1.4.1.232.167.2.4.5.2.1.6 integer read-write
Value for high setpoint of sensor
                             waterCoolUnitSensorSetLow 1.3.6.1.4.1.232.167.2.4.5.2.1.7 integer read-write
Value for low setpoint of sensor, also used as alarm delay
                             waterCoolUnitSensorSetWarn 1.3.6.1.4.1.232.167.2.4.5.2.1.8 integer read-write
Value for warning setpoint of sensor, also used as fan threshold
                 cpqWcrmStatusWaterCoolUnitOutputs 1.3.6.1.4.1.232.167.2.4.6
                     cpqWcrmWaterCoolUnitNumberOfOutputs 1.3.6.1.4.1.232.167.2.4.6.1 integer read-only
Number of outputs available on sensor water cool unit
                     cpqWcrmWaterCoolUnitOutputTable 1.3.6.1.4.1.232.167.2.4.6.2 no-access
Headline of output table
                         cpqWcrmWaterCoolUnitOutputEntry 1.3.6.1.4.1.232.167.2.4.6.2.1 no-access
Entries of output table
                             waterCoolUnitOutputIndex 1.3.6.1.4.1.232.167.2.4.6.2.1.1 integer read-only
Index for the list of output entries. Its value ranges between 1 and the value of cpqWcrmWaterCoolUnitNumberOfOutputs.
                             waterCoolUnitOutputType 1.3.6.1.4.1.232.167.2.4.6.2.1.2 integer read-only
Type of output which is connected to water cool unit to output[waterCoolUnitOutputIndex] 1: no output connected 2: output failure 3: value overflow 4: water valve setpoint 5: water valve hysteresis 6: command for manual control 7: Flow Meter Model, 0=SIKA, 1=Chemline 8: minimum fan speed 9: min delta T, used for fan control 10: max delta T, used for fan control 11: specific heat capacity 12: setpoint heatload warning 13: setpoint Water Flow Loss Emergency Door Opening 14: setpoint High Temperature Emergency Door Opening 15: setpoint Condensation Pump Cycles (Warning) 16: setpoint Condensation Pump Running Time (Warning) 17: command for door opening, 0=lock door, 1=unlock door 18: KP parameter for PID controller 19: KI parameter for PID controller 20: KD parameter for PID controller 21: sampling time PID controller Enumeration: 'setCondCycles': 15, 'setCondRun': 16, 'pidContrKD': 20, 'setHeatload': 12, 'cpWatert': 11, 'pidSampleTime': 21, 'pidContrKI': 19, 'setpoint': 4, 'dTmax': 10, 'doorControl': 17, 'setEdoHeat': 14, 'hysteresis': 5, 'pidContrKP': 18, 'failure': 2, 'command': 6, 'dTmin': 9, 'setEdoFlow': 13, 'notAvail': 1, 'overflow': 3, 'controlMode': 7, 'fanSpeedMin': 8.
                             waterCoolUnitOutputText 1.3.6.1.4.1.232.167.2.4.6.2.1.3 displaystring read-write
Descriptional text for each output (entry in the table)
                             waterCoolUnitOutputStatus 1.3.6.1.4.1.232.167.2.4.6.2.1.4 integer read-write
Actual status of the output Enumeration: 'on': 6, 'ok': 4, 'setOn': 8, 'lost': 2, 'setOff': 7, 'changed': 3, 'notAvail': 1, 'off': 5.
                             waterCoolUnitOutputValue 1.3.6.1.4.1.232.167.2.4.6.2.1.5 integer read-write
Signed value for output
                             waterCoolUnitOutputSet 1.3.6.1.4.1.232.167.2.4.6.2.1.6 integer read-write
Command for output Enumeration: 'on': 2, 'unlock': 4, 'off': 1, 'unlockDelay': 5, 'lock': 3.
                             waterCoolUnitOutputConfig 1.3.6.1.4.1.232.167.2.4.6.2.1.7 integer read-write
Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control Enumeration: 'enRemote': 2, 'disRemote': 1.
                             waterCoolUnitOutputDelay 1.3.6.1.4.1.232.167.2.4.6.2.1.8 integer read-write
Unsigned Value for delay, after this time the output will fall into the previous state
                             waterCoolUnitOutputTimeoutAction 1.3.6.1.4.1.232.167.2.4.6.2.1.9 integer read-write
State for output if timeout (RS422) occurs Enumeration: 'on': 3, 'off': 2, 'stay': 1.
                 cpqWcrmStatusWaterCoolUnitMsg 1.3.6.1.4.1.232.167.2.4.7
                     cpqWcrmWaterCoolUnitNumberOfMsgs 1.3.6.1.4.1.232.167.2.4.7.1 integer read-only
Number of alarms that can be created with water cool unit
                     cpqWcrmWaterCoolUnitMsgTable 1.3.6.1.4.1.232.167.2.4.7.2 no-access
Headline of message table
                         cpqWcrmWaterCoolUnitMsgEntry 1.3.6.1.4.1.232.167.2.4.7.2.1 no-access
Entries of message table
                             waterCoolUnitMsgIndex 1.3.6.1.4.1.232.167.2.4.7.2.1.1 integer read-only
Index for the list of alarm entries. Its value ranges between 1 and the value of cpqWcrmWaterCoolUnitNumberOfMsgs.
                             waterCoolUnitMsgText 1.3.6.1.4.1.232.167.2.4.7.2.1.2 displaystring read-write
Descriptional text for each message (entry in the table)
                             waterCoolUnitMsgStatus 1.3.6.1.4.1.232.167.2.4.7.2.1.3 integer read-only
Actual message status 4: OK 5: alarm 6: warning 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold Enumeration: 'setOff': 9, 'configChanged': 2, 'ok': 4, 'setOn': 10, 'tooHigh': 8, 'alarm': 5, 'warning': 6, 'notAvail': 1, 'error': 3, 'tooLow': 7.
                             waterCoolUnitMsgRelay 1.3.6.1.4.1.232.167.2.4.7.2.1.4 integer read-write
Setup of Alarm relay for this alarm 2: no switching of alarm relay 1: switching of alarm relay Enumeration: 'enable': 2, 'disable': 1.
                             waterCoolUnitMsgBeeper 1.3.6.1.4.1.232.167.2.4.7.2.1.5 integer read-write
Setup of Alarm beeper for this alarm 2: no audible alarm 1: audible alarm Enumeration: 'enable': 2, 'disable': 1.
                             waterCoolUnitMsgTrap1 1.3.6.1.4.1.232.167.2.4.7.2.1.6 integer read-write
Trap receiver 1 activated Enumeration: 'enable': 2, 'disable': 1.
                             waterCoolUnitMsgTrap2 1.3.6.1.4.1.232.167.2.4.7.2.1.7 integer read-write
Trap receiver 2 activated Enumeration: 'enable': 2, 'disable': 1.
                             waterCoolUnitMsgTrap3 1.3.6.1.4.1.232.167.2.4.7.2.1.8 integer read-write
Trap receiver 3 activated Enumeration: 'enable': 2, 'disable': 1.
                             waterCoolUnitMsgTrap4 1.3.6.1.4.1.232.167.2.4.7.2.1.9 integer read-write
Trap receiver 4 and Event Logging activated Enumeration: 'enable': 2, 'disable': 1.
                             waterCoolUnitMsgReset 1.3.6.1.4.1.232.167.2.4.7.2.1.10 integer read-write
Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key Enumeration: 'auto': 1, 'manual': 2.
             cpqWcrmURL 1.3.6.1.4.1.232.167.2.7 displaystring read-only
URL of the management interface in the format http[s]://ipaddr[:port#][/page]
         cpqWcrmSetup 1.3.6.1.4.1.232.167.3
             cpqWcrmSetupGeneral 1.3.6.1.4.1.232.167.3.1
                 cpqWcrmSetTempUnit 1.3.6.1.4.1.232.167.3.1.1 integer read-write
Unit of all temperature values and setpoints, Celsius or Fahrenheit Enumeration: 'fahrenheit': 2, 'celsius': 1.
                 cpqWcrmSetBeeper 1.3.6.1.4.1.232.167.3.1.2 integer read-write
Audible alarm in Environmental Controller unit: (2): beeper is on (1): beeper is off (general) Enumeration: 'on': 2, 'off': 1.
                 cpqWcrmResetRelay 1.3.6.1.4.1.232.167.3.1.3 integer read-write
Enable or disable acknowledging currently active alarm relay (with 'C' on Environmental Controller). Enumeration: 'disabled': 1, 'enabled': 2.
                 cpqWcrmLogicRelay 1.3.6.1.4.1.232.167.3.1.4 integer read-write
Logic of alarm relay: (1) Relay will pick up in case of an alarm (2) Relay will release in case of an alarm (3) Relay off (general) Enumeration: 'off': 3, 'openAtAlarm': 2, 'closeAtAlarm': 1.
                 cpqWcrmWebAccess 1.3.6.1.4.1.232.167.3.1.5 integer read-write
Web access via HTTP: (1) view only (2) full Access, read and set (3) Web disabled (general) Enumeration: 'viewOnly': 1, 'fullAccess': 2, 'off': 3.
                 cpqWcrmSetupDate 1.3.6.1.4.1.232.167.3.1.6 displaystring read-write
actual Date in format DD.MM.YYYY
                 cpqWcrmSetupTime 1.3.6.1.4.1.232.167.3.1.7 displaystring read-write
actual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59)
                 cpqWcrmTimerTable1 1.3.6.1.4.1.232.167.3.1.8
                     cpqWcrmTimerNumber 1.3.6.1.4.1.232.167.3.1.8.1 integer read-only
Number of value-table entries=number of outlets available on this unit
                     cpqWcrmTimerTable 1.3.6.1.4.1.232.167.3.1.8.2 no-access
Headline of status-table
                         cpqWcrmTimerEntry 1.3.6.1.4.1.232.167.3.1.8.2.1 no-access
Entries of timer-table
                             cpqWcrmTimerIndex 1.3.6.1.4.1.232.167.3.1.8.2.1.1 integer read-only
Index for the list of timer entries. Its value ranges between 1 and the value of cpqWcrmTimerNumber.
                             cpqWcrmTimerStatus 1.3.6.1.4.1.232.167.3.1.8.2.1.2 integer read-only
Actual status of the timer Enumeration: 'switchedOn': 2, 'noTime': 3, 'switchedOff': 1.
                             cpqWcrmTimerDayOfWeek 1.3.6.1.4.1.232.167.3.1.8.2.1.3 integer read-write
Selection of day of week for timer to switch Enumeration: 'mon-sun': 10, 'wed': 4, 'sun': 1, 'th': 5, 'tue': 3, 'mon': 2, 'mon-fri': 9, 'fri': 6, 'sat-sun': 8, 'sat': 7.
                             cpqWcrmTimeOn 1.3.6.1.4.1.232.167.3.1.8.2.1.4 displaystring read-write
Time to switch on current function, Format: HH:MM
                             cpqWcrmTimeOff 1.3.6.1.4.1.232.167.3.1.8.2.1.5 displaystring read-write
Time to switch off current function, Format: HH:MM
                             cpqWcrmTimeControl 1.3.6.1.4.1.232.167.3.1.8.2.1.6 integer read-write
Control via RTC Enumeration: 'disabled': 1, 'enabled': 2.
                             cpqWcrmTimerFunction 1.3.6.1.4.1.232.167.3.1.8.2.1.7 integer read-write
Function which is controlled via timer 1-4: sending Traps to this Trap receiver will be disabled 5 - 8: scheduled alarm off Enumeration: 'schedule4': 8, 'disTrapRec2': 2, 'schedule3': 7, 'disTrapRec4': 4, 'schedule1': 5, 'schedule2': 6, 'disTrapRec3': 3, 'disTrapRec1': 1.
                 cpqWcrmSetFlowUnit 1.3.6.1.4.1.232.167.3.1.9 integer read-write
Unit of Water Flow, Liter/min or Gallon/min Enumeration: 'literMin': 1, 'gallonMin': 2.
         cpqWcrmTrapControl 1.3.6.1.4.1.232.167.4
             cpqWcrmTraps 1.3.6.1.4.1.232.167.4.7
                 cpqWcrmTraptableNumber 1.3.6.1.4.1.232.167.4.7.1 integer read-only
Number of trapTable entries. The number of trap-receiver
                 cpqWcrmTrapTableTable 1.3.6.1.4.1.232.167.4.7.2 no-access
A list of trap-receiver entries
                     cpqWcrmTrapTableEntry 1.3.6.1.4.1.232.167.4.7.2.1 no-access
Entries of trapTable
                         trapIndex 1.3.6.1.4.1.232.167.4.7.2.1.1 integer read-only
Index for the trap-receiver-table. Its value ranges between 1 and the value of traptableNumber
                         trapStatus 1.3.6.1.4.1.232.167.4.7.2.1.2 integer read-write
Enable or disable trap receiver Enumeration: 'disabled': 1, 'enabled': 2.
                         trapIPaddress 1.3.6.1.4.1.232.167.4.7.2.1.3 displaystring read-write
IP-address of trap-receiver
         cpqWcrmControl 1.3.6.1.4.1.232.167.5
             cpqWcrmResetUnit 1.3.6.1.4.1.232.167.5.1 integer read-write
Command to reset (acknowledge) alarms of Environmental Controller unit. Setting to 'reset' (2) will have same result as pressing 'C' on Units. Variable is automatically set back to 'noReset' (1). Enumeration: 'reset': 2, 'noReset': 1.
           alarmSensorInternal 1.3.6.1.4.1.232.1670.1
Internal Sensor Alarm
           alarmSensorWaterCoolUnit 1.3.6.1.4.1.232.1670.2
Water Cool Unit Sensor Alarm
           alarmInternal 1.3.6.1.4.1.232.1670.5
Internal Unit Alarm
           alarmWaterCoolUnit 1.3.6.1.4.1.232.1670.6
Water Cool Unit System Alarm
           testTrap 1.3.6.1.4.1.232.1670.10
Test trap sent to a trap receiver to check proper reception of traps