CPQSERVICE-MIB: View SNMP OID List / Download MIB

VENDOR: COMPAQ


 Home MIB: CPQSERVICE-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 cpqService 1.3.6.1.4.1.232.164
         cpqServiceMibRev 1.3.6.1.4.1.232.164.1
             cpqServiceMibRevMinor 1.3.6.1.4.1.232.164.1.1 integer read-only
The Minor Revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
             cpqServiceMibRevMajor 1.3.6.1.4.1.232.164.1.2 integer read-only
The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information. Correct interpretation of data may require a MIB document with the same major revision level.
         cpqServiceIncident 1.3.6.1.4.1.232.164.2
             cpqServiceIncidentSeverity 1.3.6.1.4.1.232.164.2.1 integer read-only
The severity of the service incident. Enumeration: 'important': 1, 'informational': 2.
             cpqServiceIncidentStatus 1.3.6.1.4.1.232.164.2.2 integer read-only
The status of the service incident. Enumeration: 'assigned': 5, 'delivered': 3, 'intransit': 2, 'submitted-to-ISEE': 7, 'undelivered': 4, 'other': 1, 'closed': 6.
             cpqServiceIncidentInformation 1.3.6.1.4.1.232.164.2.3 displaystring read-only
Provides the URL to the event analysis report.
             cpqServiceIncidentEvent 1.3.6.1.4.1.232.164.2.4 displaystring read-only
Brief description of the event that initiated the service incident.
             cpqServiceIncidentUniqueID 1.3.6.1.4.1.232.164.2.5 displaystring read-only
Unique Event Analysis Identifier assigned to the incident.
             cpqServiceIncidentTimeofOriginalEvent 1.3.6.1.4.1.232.164.2.6 displaystring read-only
Time of the original event this service event relates to.
             cpqServiceIncidentSourceSystemName 1.3.6.1.4.1.232.164.2.7 displaystring read-only
Name of the system this service event relates to.
             cpqServiceIncidentIPAddessOfSource 1.3.6.1.4.1.232.164.2.8 ipaddress read-only
IP Address of the system this service event relates to.
             cpqServiceISEEIncidentInformation 1.3.6.1.4.1.232.164.2.9 displaystring read-only
This is a URL pointing to the Service Incident status in ISEE if available.
             cpqServiceIncidentIdentifier 1.3.6.1.4.1.232.164.2.10 displaystring read-only
Service Incident Identifier assigned to the incident report by the ISEE client.
             cpqServiceIncidentReceiveTrapOID 1.3.6.1.4.1.232.164.2.11 object identifier read-only
The ID of the originally received event.
             cpqServiceIncidentFilterOID 1.3.6.1.4.1.232.164.2.12 object identifier read-only
The OID of the value that is used by the OSEM filter.
             cpqServiceIncidentFilterValue 1.3.6.1.4.1.232.164.2.13 displaystring read-only
The value contained in the Filter OID.
             cpqServiceRecommendedAction1 1.3.6.1.4.1.232.164.2.14 displaystring read-only
Recommended action.
             cpqServiceRecommendedAction2 1.3.6.1.4.1.232.164.2.15 displaystring read-only
Recommended action continued
             cpqServiceRecommendedAction3 1.3.6.1.4.1.232.164.2.16 displaystring read-only
Recommended action continued
             cpqServiceCustomerSelfRepairInstructionURL 1.3.6.1.4.1.232.164.2.17 displaystring read-only
A URL pointing to additional repair information
             cpqServiceEventSeverity 1.3.6.1.4.1.232.164.2.18 integer read-only
The severity of the service incident. Enumeration: 'informational': 5, 'major': 2, 'critical': 1, 'warning': 4, 'minor': 3.
             cpqServiceAnalyzerSystemName 1.3.6.1.4.1.232.164.2.19 displaystring read-only
Name of the system this service event was analyzed on.
             cpqServiceFRUList1 1.3.6.1.4.1.232.164.2.20 displaystring read-only
Replaceable Unit information
             cpqServiceFRUList2 1.3.6.1.4.1.232.164.2.21 displaystring read-only
Replaceable Unit information continued
             cpqServiceFRUList3 1.3.6.1.4.1.232.164.2.22 displaystring read-only
Replaceable Unit information continued
             cpqServiceFRUList4 1.3.6.1.4.1.232.164.2.23 displaystring read-only
Replaceable Unit information continued
             cpqServiceLocation1 1.3.6.1.4.1.232.164.2.24 displaystring read-only
Replaceable Unit location
             cpqServiceLocation2 1.3.6.1.4.1.232.164.2.25 displaystring read-only
Replaceable Unit location continued
           cpqServiceInformation 1.3.6.1.4.1.232.1640.164001
This trap will be sent any time a service incident is logged or updated. A service incident is generated when it is determined that a service event has occurred based upon an analysis of system initiated event traps or an update to a service event has occurred. User Action: None Required
           cpqService2Information 1.3.6.1.4.1.232.1640.164002
This event will be sent any time a service incident is reported. A service incident is generated when it is determined that a serviceable event has occurred based upon analysis of system-initiated events. User Action: Refer to the Recommended Action section under the event details section
           cpqService3Information 1.3.6.1.4.1.232.1640.164003
This event will be sent any time a service incident is reported. A service incident is generated when it is determined that a serviceable event has occurred based upon analysis of system-initiated events. User Action: Refer to the Recommended Action section under the event details section