CONTIVITY-TRAPS-V1-MIB: View SNMP OID List / Download MIB

VENDOR: NEW OAK COMMUNICATIONS


 Home MIB: CONTIVITY-TRAPS-V1-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 coldStart 1.3.6.1.2.1.110.0
A coldStart trap signifies that the SNMPv2 entity, acting in an agent role, is reinitializing itself and that its configuration may have been altered.
 linkDown 1.3.6.1.2.1.110.2
A linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communication links represented in the agent's configuration. Varbind list: ifIndex -- ifIndex of the interface. ifAdminStatus -- ifAdminStatus of the interface. ifOperStatus -- ifOperStatus of the interface. ifDescr -- ifDescr of the interface. ifType -- ifType, this provides descrimination of interfaces that are tunnels. ifReasonForStatus-ces -- reason for the change in status. ifPhysLocation-ces -- this is the slot number. ifPhysRelPos-ces -- the port number on the board defined in interfacePhysLocation. ifIpAddr-ces -- IP address assigned to the phys port or the local IP address of a tunnel. ifName-ces -- Name of the tunnel or physical interface. ifTunnelRemoteIpAddr-ces -- for non-tunnel interfaces it is zero. sysObjectID -- sysObjectID of the unit. sysName -- sysName of the unit.
 linkUp 1.3.6.1.2.1.110.3
A linkUp trap signifies that the sending protocol entity recognizes that one of the communication links represented in the agent's configuration has come up. Varbind list: ifIndex -- ifIndex of the interface. ifAdminStatus -- ifAdminStatus of the interface. ifOperStatus -- ifOperStatus of the interface. ifDescr -- ifDescr of the interface. ifType -- ifType, this provides descrimination of interfaces that are tunnels. ifReasonForStatus-ces -- reason for the change in status ifPhysLocation-ces -- this is the slot number. ifPhysRelPos-ces -- the port number on the board defined in interfacePhysLocation. ifIpAddr-ces -- IP address assigned to the phys port or the local IP address of a tunnel. ifName-ces -- Name of the tunnel or physical interface. ifTunnelRemoteIpAddr-ces -- for non-tunnel interfaces it is zero. sysObjectID -- sysObjectID of the unit. sysName -- sysName of the unit.
 authenticationFailure 1.3.6.1.2.1.110.5
An authenticationFailure trap signifies that the SNMPv2 entity, acting in an agent role, has received a protocol message that is not properly authenticated. The snmpEnableAuthenTraps object indicates whether this trap will be generated. snmpAuthenOperation-ces identifies the operation( ie. GetRequest, GetNextRequest,... ) was being attempted. snmpAuthenIpAddress-ces identifies the source IP address of the operation. snmpAuthenCommString-ces identifies the community string that was used in the operation.
       contivityTrapsV1 1.3.6.1.4.1.2505.1.0
This MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router.
       hardwareCESTrapInfo 1.3.6.1.4.1.2505.1.1
           hardDisk1Status 1.3.6.1.4.1.2505.1.1.1 displaystring read-only
Hard Disk Number 1 Status. Possible Values: Warning: Hard Disk 1 : Device /ide1/ not available Warning: Hard Disk 1 : Utilization exceeds 75%% on /ide1/ Alert: Hard Disk 1 : Utilization exceeds 87.5%% on /ide1/
           hardDisk0Status 1.3.6.1.4.1.2505.1.1.2 displaystring read-only
Hard Disk Number 0 Status. Possible Values: Warning: Hard Disk 0 : Device /ide0/ not available Warning: Hard Disk 0 : Utilization exceeds 75%% on /ide0/ Alert: Hard Disk 0 : Utilization exceeds 87.5%% on /ide0/
           memoryUsage 1.3.6.1.4.1.2505.1.1.3 displaystring read-only
Memory Usage Status. Possible Values: Warning: Memory Usage : Utilization exceeds 75% Alert: Memory Usage : Utilization exceeds 87.5%
           lanCardStatus 1.3.6.1.4.1.2505.1.1.4 displaystring read-only
Status of any LAN cards on the system. Possible Values: Please note that X corresponds to the Xth slot in the system. Please note that Y corresponds to the relative position of the port on the card in the Xth slot in the system. Warning: LAN on Slot X Interface Y: Device feiX has no IP address; Warning: LAN on Slot X Interface Y: Device feiX disabled; Alert: LAN on Slot X Interface Y: Device feiX down; Alert: LAN on Slot X Interface Y: Device feiX Invalid Device X The Alert status above indicates that the interface has no link when it should. Possible causes are improper connection speeds and duplex, improper cabling or a configuration issue.
           cpuTwoStatus 1.3.6.1.4.1.2505.1.1.5 displaystring read-only
Status of second CPU. Possible Values: Alert: CPU 2: Program load failed; Alert: CPU 2: Bootup did not complete; Alert: CPU 2: Communication lost; Alert: CPU 2: Failed. Reason unknown; Each of these indicates that the application CPU is not functioning correctly. The system will continue to function without the application processor. This can only be sent from a system with multiple CPUs. See the Admin Guide for a list of systems that contain multiple CPUs. The CES will emit an audible alarm and the networking performance will be degraded. A Nortel support representative should be contacted if rese ing the CES does not correct the problem. The effect is the same in each case. The system will be running with only one CPU.
           fanOneStatus 1.3.6.1.4.1.2505.1.1.6 displaystring read-only
Status of the first CPU fan. Possible Values: Alert: CPU One Fan: Fan not functioning; This indicates that the fan on the primary processor is running either below the specified speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. This is a high priority event which can prove catastrophic to the processor as well as the system. This trap can only be sent by systems which contain an actual fan on the primary CPU.
           fanTwoStatus 1.3.6.1.4.1.2505.1.1.7 displaystring read-only
Status of the second CPU fan Possible Values: Alert: CPU Two Fan: Fan not functioning; This indicates that the fan on the auxiliary processor is running either below the specified speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. This is a high priority event which can prove catastrophic to the processor as well as the system. This trap can only be sent by systems which contain an actual fan on the auxiliary CPU.
           chassisFanStatus 1.3.6.1.4.1.2505.1.1.8 displaystring read-only
Status of the chassis fan. Possible Values: Alert: Chassis Fan: Fan not functioning; Alert: Chassis Fan 2: Fan not functioning; This indicates that one of the chassis fans is running either below the specified range of speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. If either of the fans are not working properly, the box must be looked at by a service technician as soon as possible. Not doing so will result in overheating of the system, improper system operation, and possible component failure.
           fiveVoltsPositive 1.3.6.1.4.1.2505.1.1.9 displaystring read-only
Status of +5 Volt power. Possible Values: Alert: Voltage 5 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
           fiveVoltsMinus 1.3.6.1.4.1.2505.1.1.10 displaystring read-only
Status of -5 Volt power. Possible Values: Alert: Voltage 5 V Minus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
           threeVoltsPositive 1.3.6.1.4.1.2505.1.1.11 displaystring read-only
Status of +3 Volt power. Possible Values: Alert: Voltage 3.3 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
           twoDotFiveVA 1.3.6.1.4.1.2505.1.1.12 displaystring read-only
Status of 2.5VA power. Possible Values: Alert: Voltage 2.5 VA: Voltage out of range; This is the voltage supplied to the primary processor. The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
           twoDotFiveVB 1.3.6.1.4.1.2505.1.1.13 displaystring read-only
Status of 2.5VB power. Possible Values: Alert: Voltage 2.5 VB: Voltage out of range; This is the voltage supplied to the seconary processor. The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
           twelveVoltsPositive 1.3.6.1.4.1.2505.1.1.14 displaystring read-only
Status of +12 Volt power. Possible Values: Alert: Voltage 12 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
           twelveVoltsMinus 1.3.6.1.4.1.2505.1.1.15 displaystring read-only
Status of -12 Volt power. Possible Values: Alert: Voltage 12 V Minus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
           normalTemperature 1.3.6.1.4.1.2505.1.1.16 displaystring read-only
Status of normal temperature reading. Possible Values: Alert: Normal Temperature: Normal temperature out of range; This indicates that the box is running above its rated normal operating temperature. This may be the result of an improperly working fan or a high ambient temperature. The box is not guaranteed to run properly while running above the normal operating temperature range. Performance will be degraded. Not taking action to correct this situation can result in component failure. Do not rely on waiting for the criticalTemperatureTrap as that is only supported by certain platforms.
           criticalTemperature 1.3.6.1.4.1.2505.1.1.17 displaystring read-only
Status of critical temperature reading. Possible Values: Alert: Critical Temperature: Critial temperature out of range; This indicates that the box is running at a critically high temperature above the normal operating range. This is only supported on certain platforms. See the Admin Guide for a list of platforms which support this. The box must be shut down immediately. Component failure may already have occurred. If the reason for such a high operating temperature cannot be determined, contact a qualified Nortel representative.
           chassisIntrusion 1.3.6.1.4.1.2505.1.1.18 displaystring read-only
The chassis intrusion sensor indicates that the unit has been opened. Possible Values: Alert: Intrusion: Box has been opened; The cover to the CES has been opened or is in the process of being opened. This indicates a possible physical security intrusion. The system will continue to operate while the box is opened. Check to insure that no unauthorized persons have opened the unit.
           dualPowerSupply 1.3.6.1.4.1.2505.1.1.19 displaystring read-only
Status of the redundant power supplies. Possible Values: Alert: Dual Power Supply: Redundant supply faulted This indicates that, on systems with redundant power supplies, one of the power supplies is not working. This trap can only be sent from systems which have redundant power supplies. The system will continue to run with only one power supply working. A new power supply must be obtained via an authorized Nortel representative as quickly as possible. This will help reduce the risk window of system failure in the event that the working power supply ceases to function.
           t1WANStatus 1.3.6.1.4.1.2505.1.1.20 displaystring read-only
Status of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device WanicX not initialized Warning: Device WanicX PPP negotiating Alert: Device WanicX PPP down Alert: Device WanicX FR no support Alert: Device WanicX Unknown DL For T1: Alert: Invalid Device X Warning: Device LMCDTEX disabled Alert: Device LMCDTEX down Warning: Device LMCDTEX not initialized For CSU/DSU: Alert: Invalid Device X Warning: Device LMCCDX disabled Alert: Device LMCCDX down Warning: Device LMCCDX not initialized
           t3WANStatus 1.3.6.1.4.1.2505.1.1.21 displaystring read-only
Status of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Alert: Device HSSIX PPP down Warning: Device HSSIX PP initializing
           hwAccelStatus 1.3.6.1.4.1.2505.1.1.22 displaystring read-only
Status of hardware accelerator card.
           v90WANStatus 1.3.6.1.4.1.2505.1.1.24 displaystring read-only
Status of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: V.90 Invalid index X Disabled: Device IntModem-X disabled Healthy: Device IntModem-X: PPP is UP. Alert: Device IntModem-X down Warning: Device IntModem-X not initialized Alert: Device IntModem-X: Call is UP. Internal Error. Warning: Device IntModem-X is Down. Last dial-out attempt FAILED. Healthy: Device IntModem-X is Down (No Active calls) Warning: Device IntModem-X is in an UNKNOWN state
           briWANStatus 1.3.6.1.4.1.2505.1.1.25 displaystring read-only
Status of ISDN BRI Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: BRI Invalid index X Alert: Device BRI-X not Responding. Needs Host Reboot. Disabled: Device BRI-X disabled Alert: Device BRI-X down Warning: Device BRI-X not initialized Healthy: Device BRI-X: PPP is UP. Alert: Device BRI-X: Call is UP. Internal Error. Warning: Device BRI-X is Down. Last dial-out attempt FAILED. Healthy: Device BRI-X is Down (No Active calls) Alert: Device BRI-X is in an UNKNOWN state
           serUartStatus 1.3.6.1.4.1.2505.1.1.26 displaystring read-only
Status of Serial (COM) port/interface Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: COM port Invalid index X Healthy: Device COMX is set for Serial Menu. Disabled: Device COMX disabled Warning: Device COMX not initialized Healthy: Device COMX: PPP is UP. Alert: Device COMX: Call is UP. Internal Error. Warning: Device COMX is Down. Last dial-out attempt FAILED. Healthy: Device COMX is Down (No Active calls) Alert: Device COMX is in an UNKNOWN state
           adslWANStatus 1.3.6.1.4.1.2505.1.1.27 displaystring read-only
Status of ADI ADSL card Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: Invalid index X Alert: Device ADIADSLX off line Disabled: Device ADIADSLX disabled Alert: Device ADIADSLX down Warning: Device ADIADSLX not initialized Healthy: Device ADIADSLX up
       serverCESTrapInfo 1.3.6.1.4.1.2505.1.2
           radiusAcctServer 1.3.6.1.4.1.2505.1.2.1 displaystring read-only
Status of External Radius Accounting Server. Possible Values: Warning: RADIUS Accounting Server: Server not configured Alert: RADIUS Accounting Server: Error Alert: RADIUS Accounting Server: Not Configured
           backupServer 1.3.6.1.4.1.2505.1.2.2 displaystring read-only
Status of External Disk Backup Server. Possible Values: Warning: Auto Backup Servers: Server not configured. Warning: Auto Backup Servers: Can't backup to xxx yyy zzz Alert: Auto Backup Servers: Can't backup to xxx yyy zzz Can't backup to xxx yyy zzz is issued as an alert when none of the servers can be reached.
           diskRedundency 1.3.6.1.4.1.2505.1.2.3 displaystring read-only
Status of Local Disk Redundency. Possible Values: Alert: Disk Redundancy: Not Configured Alert: Disk Redundancy: Error
           intLDAPServer 1.3.6.1.4.1.2505.1.2.4 displaystring read-only
Status of Internal LDAP Server. Possible Values: Warning : Internal LDAP Server : Restore in progress Alert : Internal LDAP Server : Server is down
           loadBalancingServer 1.3.6.1.4.1.2505.1.2.5 displaystring read-only
Status of Load Balancing Server. Possible Values: Disabled: Load Balancing Service: Server not enabled; Warning: Load Balancing Service: Timed out waiting for response from server;
           dnsServer 1.3.6.1.4.1.2505.1.2.6 displaystring read-only
Status of DNS Server. Possible Values: Warning: DNS Servers : Error Warning: DNS Servers : Operational Alert: DNS Servers : Configured Alert: DNS Servers : Error The values have the following meaning: Warning: DNS Servers : Error -- SysInitCls::InitComplete failed Warning: DNS Servers : Operational -- At least one of the servers is reachable Alert: DNS Servers : Configured -- All servers configured, but none are reachable. Alert: DNS Servers : Error --
           snmpServer 1.3.6.1.4.1.2505.1.2.7 displaystring read-only
Status of SNMP Server. Possible Values: Warning: SNMP Servers : Error Warning: SNMP Servers : Can't reach xxx.xxx.xxx.xxx or yyy.yyy.yyy.yyy Alert: SNMP Servers : Error The values have the following meaning: Warning: SNMP Servers : Error -- SysInitCls::InitComplete failed Alert: SNMP Servers : Error -- AT least one server configured, but none are reachable.
           ipAddressPool 1.3.6.1.4.1.2505.1.2.8 displaystring read-only
Status of the IP address pool. Possible Values: Warning: IP Address Pool : Reserved address count is low. Warning: IP Address Pool : DHCP server(s) unavailable Alert: IP Address Pool : Server is down Alert: IP Address Pool : Not Configured Alert: IP Address Pool : No IP address available. Alert: IP Address Pool : Reserved address count is low. Alert: IP Address Pool : Associated system task failed. Alert: IP Address Pool : Server not configured Alert: IP Address Pool : Error The values have the following meaning: Warning: IP Address Pool : Reserved address count is low. -- Haven't hit desired cache size yet. Alert: IP Address Pool : Server is down -- SysInitCls::InitComplete failed Alert: IP Address Pool : Not Configured -- Task failed sanity check. Alert: IP Address Pool : No IP address available. -- No addresses in BOUND state. Alert: IP Address Pool : Associated system task failed. Alert: IP Address Pool : Server not configured Alert: IP Address Pool : Error
           extLDAPServer 1.3.6.1.4.1.2505.1.2.9 displaystring read-only
Status of External LDAP Server. Possible Values: Warning: External LDAP Servers : Server is down Alert: External LDAP Servers : Server is down The values have the following meaning: Warning: External LDAP Servers : Server is down -- One server is down Alert: External LDAP Servers : Server is down -- All servers are down
           radiusAuthServer 1.3.6.1.4.1.2505.1.2.10 displaystring read-only
Status of Radius Authentication Server. Possible Values: Warning: RADIUS Authentication Servers : Error Alert: RADIUS Authentication Servers : Error The values have the following meaning: Warning: RADIUS Authentication Servers : Error -- At least one server is available Alert: RADIUS Authentication Servers : Error -- No servers are available
           certificateServer 1.3.6.1.4.1.2505.1.2.11 displaystring read-only
Status of Certificates Validity. Possible Values: Alert: Certificates Validity: All certificates are going to expire/expired; Warning: Certificates Validity: One/more certificate is invalid; Disabled: Certificates Validity: No certificate defined;
           extLDAPAuthServer 1.3.6.1.4.1.2505.1.2.12 displaystring read-only
Status of External LDAP Authentication Server. Possible Values: Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable); Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);
           cmpServer 1.3.6.1.4.1.2505.1.2.13 displaystring read-only
Status of CMP Server. Possible Values: One/more Certificate Requests error: there is at least one request error; One/more Certificate Requests processing: there is at least one request in processing; No Certificate Requests submitted: there is no request sent;
           dhcpServer 1.3.6.1.4.1.2505.1.2.14 displaystring read-only
Status of DHCP Server. Possible Values: Disabled: DHCP Server is Disabled Alert: DHCP Server is NOT configured Alert: DHCP Server is configured and operational, Using backup config Alert: No IP Address available for subnet Alert: DHCP Server is configured and server is DOWN Healthy: DHCP Server is Operational Warning: Subnet low on IP Addresses Warning: DHCP Server Initializing Warning: DHCP Server is Enabled, but status Unknown cannot be determined
           sshServer 1.3.6.1.4.1.2505.1.2.15 displaystring read-only
Status of SSH Server. Possible Values: Disabled : -- SSH Server is Disabled Healthy : -- SSH Server is Operational Warning : -- SSH Server is Restarting Warning : -- SSH Server is Initializing Warning : -- SSH Server is Unknown Alert : -- SSH Server is Down
           ntpServer 1.3.6.1.4.1.2505.1.2.16 displaystring read-only
Status of NTP Server. Possible Values: Disabled : -- NTP server is globally disabled. Healthy : -- NTP server operational. Warning : -- Frequency correction. Warning : -- Frenquncy set. Warning : -- Time set. Warning : -- Spike detected. Warning : -- Clock synchronized. Warning : -- NTP initialized - not synchronized. Warning : -- Clock never set.
           ospfServer 1.3.6.1.4.1.2505.1.2.17 displaystring read-only
Status of OSPF Server. Possible Values: Disabled : -- OSPF is globally disabled Warning : -- OSPF tunnel local addr A.B.C.D remote addr A.B.C.D is DOWN Warning : -- OSPF interface A.B.C.D is DOWN Alert : -- No connection to Routing Table Manager Alert : -- No connection to Routing Policy Service Healthy : -- Operational
           clipServer 1.3.6.1.4.1.2505.1.2.18 displaystring read-only
Status of Circuitless IP. Possible Values: Disabled : -- CLIP is Disabled Healthy : -- CLIP is operational
           dhcprelayServer 1.3.6.1.4.1.2505.1.2.19 displaystring read-only
Status of DHCP Relay Server. Possible Values: Alert : -- DHCP Relay requires reboot to start Alert : -- DHCP Relay task does not exist Alert : -- DHCP Relay task is suspended Healthy : -- DHCP Relay is up
           gdsServer 1.3.6.1.4.1.2505.1.2.20 displaystring read-only
Status of Global Demand Services Services. Possible Values: Healthy : -- Global Demand Services operational. Disabled : -- Global Demand Services disabled.
           demandintfServer 1.3.6.1.4.1.2505.1.2.21 displaystring read-only
Status of Demand Interface. Possible Values: Healthy : -- Demand Interface Connected. Healthy : -- Demand Interface Connecting. Healthy : -- Demand Interface Activated. Healthy : -- Demand Interface Idle. Disabled : -- Demand Interface Disabled.
           crlServer 1.3.6.1.4.1.2505.1.2.22 displaystring read-only
Status of CRL Server. Possible Values: Healthy : -- All Certificates are Valid Alert : -- One/more certificate is expired Warning : -- One/more certificate is going to expire Warning : -- Duplicate CA certs detected on the switch. Disabled : -- No certificate defined
           ocspServer 1.3.6.1.4.1.2505.1.2.23 displaystring read-only
Status of OCSP Server. Possible Values: Disabled : -- No OCSP server configured Alert : -- All OCSP servers are down. Cert:%s Warning : -- At least one server is down. Cert:%s Warning : -- OCSP is enabled but not configured. Cert:%s Healthy : -- All servers are up
       serviceCESTrapInfo 1.3.6.1.4.1.2505.1.3
           netBuffers 1.3.6.1.4.1.2505.1.3.1 displaystring read-only
Network buffer usage. Possible Values: Warning: Buffer Usage : Utilization exceeds 75% Alert: Buffer Usage : Utilization exceeds 87.5%
           fireWall 1.3.6.1.4.1.2505.1.3.2 displaystring read-only
Status of internal firewall. Possible Values: Disabled: Firewall: Firewall disabled; Disabled: Firewall: Firewall stopped; Warning: Firewall: Current Firewall is %s. Reboot is required to start %s; Warning: Firewall: Firewall state is not known!; Warning: Firewall: Daemon loading policy; Alert: Firewall: Firewall requires reboot to start; Alert: Firewall: Daemon task does not exist; Alert: Firewall: Daemon task is suspended; The values have the following meaning: -- The first two possible values are common to all firewalls. Disabled: Firewall: Firewall disabled; Warning: Firewall: Current Firewall is %s. Reboot is required to start %s; -- The firewall type (Contivity / CheckPoint) has been changed, but for it -- to take effect, the VPN Router must be restarted. -- Contivity Firewall specific values. Warning: Firewall: Firewall state is not known!; -- The Contivity firewall's -- state cannot be determined. -- CheckPoint Firewall specific values. Disabled: Firewall: Firewall stopped; Warning: Firewall: Daemon loading policy; Alert: Firewall: Firewall requires reboot to start; Alert: Firewall: Daemon task does not exist; Alert: Firewall: Daemon task is suspended;
           fipsStatus 1.3.6.1.4.1.2505.1.3.3 displaystring read-only
Status of FIPS. Possible Values: Warning: FIPS: Random generator test failed; Warning: FIPS: DESMAC check on executables Failed; Warning: FIPS: DES KAT Test Failed; Warning: FIPS: SHA1 Self Test Failed; Alert: FIPS: status not known;
           licensingStatus 1.3.6.1.4.1.2505.1.3.4 displaystring read-only
Status of temporary SW Licenses. Possible Values: Warning: Licensing: Temporary key will expire within 5 days; Alert: Licensing: Temporary key has expired;
           natStatus 1.3.6.1.4.1.2505.1.3.5 displaystring read-only
Status of Network Address Translator. Possible Values: Disabled: NAT: NAT disabled; Warning: NAT: Reboot is required to start Interface NAT; Warning: NAT: NAT state is not known!; Alert: NAT: All Addresses in the Address Translation pool are used; Alert: NAT: LDAP policy parse failed - Using system default policy; The values have the following meaning: -- The first two possible values are common to all firewalls. Disabled: NAT: NAT disabled; Existing NAT sessions are not deleted, but -- no new address bindings are created for Interface NAT. Branch Office NAT -- is not affected. Warning: NAT: Reboot is required to start Interface NAT; -- To take effect, the VPN Router must be restarted.
           antiSpoofingStatus 1.3.6.1.4.1.2505.1.3.6 displaystring read-only
Status of Anti Spoofing Feature. Possible Values: Disabled: Anti-Spoofing is Disabled; Warning: Anti-Spoofing : Packets Dropped; Alert: Anti-Spoofing state not known!; The values have the following meaning: -- The first means the feature is disabled -- The second means packets were dropped due to a detected spoofed address -- The third should never happen, but means the status has been set to a bogus value.
           sslVpnStatus 1.3.6.1.4.1.2505.1.3.7 displaystring read-only
Status of SSL-VPN Accelerator. Possible Values: Disabled: Disabled -- The unit is administrativley disabled. Disabled: HW not installed -- There is no SSL-VPN Accelerator installed. Warning: Initialization in progress. -- The unit is being Initialized. Warning: Configuration Errors - see eventlog for details. Healthy: Operational -- The unit is Operational. Alert: Unreachable: Error Comminicating with SSL-VPN
           usrIpAddrStatus 1.3.6.1.4.1.2505.1.3.8 displaystring read-only
Status of User Ip Address Pool server. Possible Values: Alert : -- Server is down. Alert : -- Object not found. Alert : -- Server Not Configured. Alert : -- No IP address available. Warning : -- Reserved address count is low. Healthy : -- User Ip Address Pool operational. Alert : -- Associated system task failed. Warning : -- No DHCP Pool selected for any group/subgroup. Warning : -- DHCP server(s) unavailable. Healthy : -- Local pool: %s; Healthy : -- DHCP pool: %s; Healthy : -- All User IP Pools are under quota exhausted. Alert : -- At least one User IP Pool exceeds %d percent
           vrrpStatus 1.3.6.1.4.1.2505.1.3.9 displaystring read-only
Status of VRRP Server. Possible Values: Disabled : -- VRRP is globally disabled Alert : -- Configuration errors -- see syslog for details Warning : -- LDAP has changed -- see syslog for details Healthy : -- VRRP is operational
           mcastRelayStatus 1.3.6.1.4.1.2505.1.3.10 displaystring read-only
Status of Multicast Relay. Possible Values: Warning : -- Multicast Relay Not Initialized Disabled : -- Multicast Relay is Globally Disabled Alert : -- RPS Reg Blocked Healthy : -- Multicast Relay is operational
           dlswStatus 1.3.6.1.4.1.2505.1.3.11 displaystring read-only
Status of DLSW Server. Possible Values: Healthy : -- DLSw local peer enabled Disabled : -- DLSw local peer disabled Disabled : -- DLSw feature disabled Disabled : -- No DLSw local peer defined
           ipsecFailoverStatus 1.3.6.1.4.1.2505.1.3.12 displaystring read-only
Status of IPsec Failover service. Possible Values: Disabled : -- Failover service disabled Healthy : -- Failover service operational Alert : -- Failover service not initialized
           tunnelGuardStatus 1.3.6.1.4.1.2505.1.3.13 displaystring read-only
Status of TunnelGuard. Possible Values: Disabled : -- Tunnelguard Disabled Healthy : -- Tunnelguard Operational Alert : -- Fatal error encountered during tunnelguard processing Warning : -- Tunnelguard state unknown!
           ripStatus 1.3.6.1.4.1.2505.1.3.14 displaystring read-only
Status of RIP Server. Possible Values: Warning : -- Rip Not Initalized Disabled : -- Rip is Globally Disabled Alert : -- RTM Open Blocked Alert : -- RPS Reg Blocked Healthy : -- RIP is operational
           routePolicyStatus 1.3.6.1.4.1.2505.1.3.15 displaystring read-only
Status of Route Policy. Possible Values: Disable : -- Routing Policy Server disabled. Alert : -- Routing Policy Server requires reboot to start. Alert : -- Routing Policy Server task does not exist. Alert : -- Routing Policy Server task is suspended. Healthy : -- Routing Policy Server is up.
           cRoutesMStatus 1.3.6.1.4.1.2505.1.3.16 displaystring read-only
Status of Client Routes Marshaler. Possible Values: Alert : -- ClientRoutesMarshaler does not exist!!! Warning : -- ClientRoutesMarshaler's task cannot be verified! Disabled: -- ClientRoutesMarshaler is disabled. Healthy : -- ClientRoutesMarshaler is UP.
           igmpStatus 1.3.6.1.4.1.2505.1.3.17 displaystring read-only
Status of IGMP Server. Possible Values: Disabled : -- IGMP is not initialized Warning : -- IGMP(CMS) is not initialized Warning : -- No Upstream interface is up Alert : -- No downstream interface is up Healthy : -- IGMP is operational
       loginCESTrapInfo 1.3.6.1.4.1.2505.1.4
           failedLogin 1.3.6.1.4.1.2505.1.4.1 displaystring read-only
Failed Login Attempt. Possible Values: Failed Login Attempt: Username=IPSEC Encrypted: Date/Time=(xx) ; Failed Login Attempt: Username=(userid): Date/Time=(xx) ; Failed Login Attempt. Invalid Account: Username=(userid): Date/Time=(xx) ; Failed Remote Network Login: Username=(userid): Date/Time=(xx) ; Failed Remote Application Login: Username=(userid): Date/Time=(xx) ; The values have the following meaning: --(userid) is a place holder for the actual userid of the person or branch office --trying to login. --(xx) is a place holder for the date and time string.
       intrusionCESTrapInfo 1.3.6.1.4.1.2505.1.5
           securityIntrusion 1.3.6.1.4.1.2505.1.5.1 displaystring read-only
Security Intrusion. Possible Values: Intruder: : Source: %s, Destination: %s;
       powerUpTrap 1.3.6.1.4.1.2505.1.6 displaystring read-only
Power Up. Possible Values: Cold Start
       severityLevel 1.3.6.1.4.1.2505.1.7 integer read-only
Severity of specific trap. Enumeration: 'disabled': 3, 'healthy': 4, 'warning': 2, 'unknown': 5, 'alert': 1.
       systemName 1.3.6.1.4.1.2505.1.8 displaystring read-only
System Name.
       systemDate 1.3.6.1.4.1.2505.1.9 displaystring read-only
System Date.
       systemTime 1.3.6.1.4.1.2505.1.10 displaystring read-only
System Time.
             hardDisk1StatusTrap 1.3.6.1.4.1.2505.1.10.1001
Hard Disk Number 1 Status
             hardDisk0StatusTrap 1.3.6.1.4.1.2505.1.10.1002
Hard Disk Number 0 Status
             memoryUsageTrap 1.3.6.1.4.1.2505.1.10.1003
Memory Usage Status
             lanCardStatusTrap 1.3.6.1.4.1.2505.1.10.1004
Status of any LAN cards on the system
             cpuTwoStatusTrap 1.3.6.1.4.1.2505.1.10.1005
Status of second CPU.
             fanOneStatusTrap 1.3.6.1.4.1.2505.1.10.1006
Status of the first CPU fan
             fanTwoStatusTrap 1.3.6.1.4.1.2505.1.10.1007
Status of the second CPU fan
             chassisFanStatusTrap 1.3.6.1.4.1.2505.1.10.1008
Status of the chassis fan.
             fiveVoltsPosStatusTrap 1.3.6.1.4.1.2505.1.10.1009
Status of the +5 Volt power
             fiveVoltsMinusTrap 1.3.6.1.4.1.2505.1.10.10010
Status of -5 Volt power
             threeVoltsPositiveTrap 1.3.6.1.4.1.2505.1.10.10011
Status of +3 Volt power
             twoDotFiveVATrap 1.3.6.1.4.1.2505.1.10.10012
Status of 2.5VA power
             twoDotFiveVBTrap 1.3.6.1.4.1.2505.1.10.10013
Status of 2.5VB power
             twelveVoltsPositveTrap 1.3.6.1.4.1.2505.1.10.10014
Status of +12 Volt power
             twelveVoltsMinsTrap 1.3.6.1.4.1.2505.1.10.10015
Status of -12 Volt power
             normalTemperatureTrap 1.3.6.1.4.1.2505.1.10.10016
Status of the normal temperature reading
             criticalTemperatureTrap 1.3.6.1.4.1.2505.1.10.10017
Status of the critical temperature reading
             chassisIntrusionTrap 1.3.6.1.4.1.2505.1.10.10018
The chassis intrusion sensor indicates that the unit has been physically opened
             dualPowerSupplyTrap 1.3.6.1.4.1.2505.1.10.10019
Status of the redundant power supplies
             t1WANStatusTrap 1.3.6.1.4.1.2505.1.10.10020
Status of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device WanicX not initialized Warning: Device WanicX PPP negotiating Alert: Device WanicX PPP down Alert: Device WanicX FR no support Alert: Device WanicX Unknown DL For T1: Alert: Invalid Device X Warning: Device LMCDTEX disabled Alert: Device LMCDTEX down Warning: Device LMCDTEX not initialized For CSU/DSU: Alert: Invalid Device X Warning: Device LMCCDX disabled Alert: Device LMCCDX down Warning: Device LMCCDX not initialized
             t3WANStatusTrap 1.3.6.1.4.1.2505.1.10.10021
Status of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Alert: Device HSSIX PPP down Warning: Device HSSIX PP initializing
             hwAccelTrap 1.3.6.1.4.1.2505.1.10.10022
Status of hardware accelerator card. Possible Values: Invalid hardware accelerator unit %d; Unknown hardware accelerator unit %d; Healthy: Bulk Accelerator in slot %d: Unit %d Status 1 - ATTACHED; Warning: Bulk Accelerator in slot %d: Unit %d Status 2 - DISABLED; Healthy: Bulk Accelerator in slot %d: Unit %d Status 3 - ACTIVE; Warning: Bulk Accelerator in slot %d: Unit %d Status 4 - RECOVERING; Warning: Bulk Accelerator in slot %d: Unit %d Status 5 - SHUTDOWN; Alert: Bulk Accelerator in slot %d: Unit %d Status 6 - FAILED;
             v90WANStatusTrap 1.3.6.1.4.1.2505.1.10.10024
Status of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: V.90 Invalid index X Disabled: Device IntModem-X disabled Healthy: Device IntModem-X: PPP is UP. Alert: Device IntModem-X down Warning: Device IntModem-X not initialized Alert: Device IntModem-X: Call is UP. Internal Error. Warning: Device IntModem-X is Down. Last dial-out attempt FAILED. Healthy: Device IntModem-X is Down (No Active calls) Warning: Device IntModem-X is in an UNKNOWN state
             briWANStatusTrap 1.3.6.1.4.1.2505.1.10.10025
Status of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: BRI Invalid index X Alert: Device BRI-X not Responding. Needs Host Reboot. Disabled: Device BRI-X disabled Alert: Device BRI-X down Warning: Device BRI-X not initialized Healthy: Device BRI-X: PPP is UP. Alert: Device BRI-X: Call is UP. Internal Error. Warning: Device BRI-X is Down. Last dial-out attempt FAILED. Healthy: Device BRI-X is Down (No Active calls) Alert: Device BRI-X is in an UNKNOWN state
             serUartStatusTrap 1.3.6.1.4.1.2505.1.10.10026
Status of Serial (COM) port/interface Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: COM port Invalid index X Healthy: Device COMX is set for Serial Menu. Disabled: Device COMX disabled Warning: Device COMX not initialized Healthy: Device COMX: PPP is UP. Alert: Device COMX: Call is UP. Internal Error. Warning: Device COMX is Down. Last dial-out attempt FAILED. Healthy: Device COMX is Down (No Active calls) Alert: Device COMX is in an UNKNOWN state
             adslWANStatusTrap 1.3.6.1.4.1.2505.1.10.10027
Status of ADI ADSL card Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: Invalid index X Alert: Device ADIADSLX off line Disabled: Device ADIADSLX disabled Alert: Device ADIADSLX down Warning: Device ADIADSLX not initialized Healthy: Device ADIADSLX up
       systemUpTime 1.3.6.1.4.1.2505.1.11 displaystring read-only
System Up Time.
       periodicHeartbeat 1.3.6.1.4.1.2505.1.12 displaystring read-only
Periodic Heartbeat. Possible Values: Has been executed n times
       snmpAgentTrapInfo_ces 1.3.6.1.4.1.2505.1.14
             snmpAgentAuthTrapInfo_ces 1.3.6.1.4.1.2505.1.14.1
                 snmpAuthenOperation_ces 1.3.6.1.4.1.2505.1.14.1.1 integer read-only
SNMP operation attempted. Enumeration: 'getNextRequest': 161, 'setRequest': 163, 'getRequest': 160, 'getBulkRequest': 165.
                 snmpAuthenIpAddress_ces 1.3.6.1.4.1.2505.1.14.1.2 ipaddress read-only
IP address of host trying to access the CES.
                 snmpAuthenCommString_ces 1.3.6.1.4.1.2505.1.14.1.3 displaystring read-only
Community string used to access the CES.
             snmpAgentInterfaceInfo_ces 1.3.6.1.4.1.2505.1.14.2
                 ifReasonForStatus_ces 1.3.6.1.4.1.2505.1.14.2.1 ifreasonforstatus_ces read-only
The reason for the status change. These include: unknown(1) -- the reason could not be determined. timed-out(2) -- connection(tunnel) timed out.
                 ifPhysLocation_ces 1.3.6.1.4.1.2505.1.14.2.2 portlocation_ces read-only
The physical location of the port. This has the values of motherBoardOrSlot0, slot1, slot2, slot3, slot4, slot5.
                 ifPhysRelPos_ces 1.3.6.1.4.1.2505.1.14.2.3 integer read-only
The relative position of the physical port at the location defined by interfacePhysLocation.
                 ifIpAddr_ces 1.3.6.1.4.1.2505.1.14.2.4 ipaddress read-only
For physical ports this is the associated IP address. For a tunnel connection it is the local IP address.
                 ifName_ces 1.3.6.1.4.1.2505.1.14.2.5 displaystring read-only
The name of the interface, same as ifName.
                 ifTunnelRemoteIpAddr_ces 1.3.6.1.4.1.2505.1.14.2.6 ipaddress read-only
The remote IP address of a tunnel connection.
             snmpAgentFirewallInfo_ces 1.3.6.1.4.1.2505.1.14.3
                 firewallPolicyType_ces 1.3.6.1.4.1.2505.1.14.3.1 firewallpolicytype_ces read-only
Policy type.
                 firewallRuleType_ces 1.3.6.1.4.1.2505.1.14.3.2 firewallruletype_ces read-only
Type of rule that triggered this event.
                 firewallRuleNumber_ces 1.3.6.1.4.1.2505.1.14.3.3 integer read-only
Number of the rule that triggered this event.
                 firewallSrcAddr_ces 1.3.6.1.4.1.2505.1.14.3.6 ipaddress read-only
Source IP address of the packet.
                 firewallSrcPort_ces 1.3.6.1.4.1.2505.1.14.3.7 integer read-only
Source port address of the packet.
                 firewallDestAddr_ces 1.3.6.1.4.1.2505.1.14.3.8 ipaddress read-only
Destination IP address of the packet.
                 firewallDestPort_ces 1.3.6.1.4.1.2505.1.14.3.9 integer read-only
Destination port of the packet.
                 firewallProtocolID_ces 1.3.6.1.4.1.2505.1.14.3.10 integer read-only
The value of the protocol field in the IP header.
                 firewallRuleAction_ces 1.3.6.1.4.1.2505.1.14.3.11 firewallruleaction_ces read-only
Action defined for the triggered rule.
                   firewallRuleTriggeredTrap 1.3.6.1.4.1.2505.1.14.30.1
An event sent at the user's request to signal that a rule has been matched. firewallPolicyType-ces -- Policy type. firewallRuleType-ces -- Type of rule that triggered this event. firewallRuleNumber-ces -- Number of the rule that triggered this event. ifIndex -- ifIndex is the index into the ifTable for port that received the packet. ifName-ces -- The name of the interface, same as ifName. firewallSrcAddr-ces -- Source IP address of the packet. firewallSrcPort-ces -- Source port address of the packet. firewallDestAddr-ces -- Destination IP address of the packet. firewallDestPort-ces -- Destination port of the packet. firewallProtocolID-ces -- The value of the protocol field in the IP header. firewallRuleAction-ces -- Action defined for the triggered rule.
             radiusAcctServerTrap 1.3.6.1.4.1.2505.1.20.3001
Status of External Radius Accounting Server
             backupServerTrap 1.3.6.1.4.1.2505.1.20.3002
Status of External Disk Backup Server
             diskRedundencyTrap 1.3.6.1.4.1.2505.1.20.3003
Status of Local Disk Redundency
             intLDAPServerTrap 1.3.6.1.4.1.2505.1.20.3004
Status of Internal LDAP Server
             loadBalancingServerTrap 1.3.6.1.4.1.2505.1.20.3005
Status of Load Balancing Server
             dnsServerTrap 1.3.6.1.4.1.2505.1.20.3006
Status of DNS Server
             snmpServerTrap 1.3.6.1.4.1.2505.1.20.3007
Status of SNMP Server
             ipAddressPoolTrap 1.3.6.1.4.1.2505.1.20.3008
Status of the IP address pool
             extLDAPServerTrap 1.3.6.1.4.1.2505.1.20.3009
Status of External LDAP Server
             radiusAuthServerTrap 1.3.6.1.4.1.2505.1.20.30010
Status of Radius Authentication Server
             certificateServerTrap 1.3.6.1.4.1.2505.1.20.30011
Status of Certificates Validity Possible Values: Healthy: Certificates Validity: Operational; Alert: Certificates Validity: All certificates are going to expire/expired; Warning: Certificates Validity: One/more certificate is invalid; Disabled: Certificates Validity: No certificate defined;
             extLDAPAuthServerTrap 1.3.6.1.4.1.2505.1.20.30012
Status of External LDAP Authentication Server. Possible Values: Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable); Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);
             cmpServerTrap 1.3.6.1.4.1.2505.1.20.30013
Status of CMP Server. Possible Values: One/more Certificate Requests error: there is at least one request error; One/more Certificate Requests processing: there is at least one request in processing; No Certificate Requests submitted: there is no request sent;
             dhcpServerTrap 1.3.6.1.4.1.2505.1.20.30014
Status of DHCP Server Possible Values: Disabled: DHCP Server is Disabled Alert: DHCP Server is NOT configured Alert: DHCP Server is configured and operational, Using backup config Alert: No IP Address available for subnet Alert: DHCP Server is configured and server is DOWN Healthy: DHCP Server is Operational Warning: Subnet low on IP Addresses Warning: DHCP Server Initializing Warning: DHCP Server is Enabled, but status Unknown cannot be determined
             sshServerTrap 1.3.6.1.4.1.2505.1.20.30015
Status of SSH Server.
             ntpServerTrap 1.3.6.1.4.1.2505.1.20.30016
Status of NTP Server.
             ospfServerTrap 1.3.6.1.4.1.2505.1.20.30017
Status of OSPF Server.
             clipServerTrap 1.3.6.1.4.1.2505.1.20.30018
Status of Circuitless IP.
             dhcprelayServerTrap 1.3.6.1.4.1.2505.1.20.30019
Status of DHCP Relay Server.
             gdsServerTrap 1.3.6.1.4.1.2505.1.20.30020
Status of Global Demand Services Services.
             demandintfServerTrap 1.3.6.1.4.1.2505.1.20.30021
Status of Demand Interface.
             crlServerTrap 1.3.6.1.4.1.2505.1.20.30022
Status of CRL Server.
             ocspServerTrap 1.3.6.1.4.1.2505.1.20.30023
Status of OCSP Server.
             netBuffersTrap 1.3.6.1.4.1.2505.1.30.5001
Network buffer usage
             fireWallTrap 1.3.6.1.4.1.2505.1.30.5002
Status of internal firewall
             fipsStatusTrap 1.3.6.1.4.1.2505.1.30.5003
Status of FIPS
             licensingStatusTrap 1.3.6.1.4.1.2505.1.30.5004
Status temporary SW Licenses
             natStatusTrap 1.3.6.1.4.1.2505.1.30.5005
Status of Network Address Translator
             antiSpoofingStatusTrap 1.3.6.1.4.1.2505.1.30.5006
Status of Anti Spoofing Feature
             sslVpnStatusTrap 1.3.6.1.4.1.2505.1.30.5007
Status of SSL-VPN Accelerator
             usrIpAddrStatusTrap 1.3.6.1.4.1.2505.1.30.5008
Status of User Ip Address Pool server
             vrrpStatusTrap 1.3.6.1.4.1.2505.1.30.5009
Status of VRRP Server
             mcastRelayStatusTrap 1.3.6.1.4.1.2505.1.30.50010
Status of Multicast Relay
             dlswStatusTrap 1.3.6.1.4.1.2505.1.30.50011
Status of DLSW Server
             ipsecFailoverStatusTrap 1.3.6.1.4.1.2505.1.30.50012
Status of IPsec Failover service
             tunnelGuardStatusTrap 1.3.6.1.4.1.2505.1.30.50013
Status of TunnelGuard
             ripStatusTrap 1.3.6.1.4.1.2505.1.30.50014
Status of RIP Server
             routePolicyStatusTrap 1.3.6.1.4.1.2505.1.30.50015
Status of Route Policy
             cRoutesMStatusTrap 1.3.6.1.4.1.2505.1.30.50016
Status of Client Routes Marshaler
             igmpStatusTrap 1.3.6.1.4.1.2505.1.30.50017
Status of IGMP Server
             failedLoginTrap 1.3.6.1.4.1.2505.1.40.101
Failed Login Attempt
             securityIntrusionTrap 1.3.6.1.4.1.2505.1.50.201
Security Intrusion
         powerUpTrapEntry 1.3.6.1.4.1.2505.10.401
Power Up
         periodicHeartbeatTrap 1.3.6.1.4.1.2505.10.601
Periodic Heartbeat