CDM-570L: View SNMP OID List / Download MIB

VENDOR: COMTECH EFDATA CORPORATION


 Home MIB: CDM-570L
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 cdm570 1.3.6.1.4.1.6247.24
Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems.
                   cdm570LBUCOption 1.3.6.1.4.1.6247.24.1.1.2.7 integer read-only
BUC option, where: 0 = None 1 = 100 watt 2 = 150 watt Enumeration: 'none': 0, 'buc100watt': 1, 'buc150watt': 2.
                   cdm570LAlarmMaskBUC 1.3.6.1.4.1.6247.24.1.2.7.9 integer read-write
BUC alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
                   cdm570LAlarmMaskLNB 1.3.6.1.4.1.6247.24.1.2.7.10 integer read-write
LNB alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
                   cdm570LBUC 1.3.6.1.4.1.6247.24.1.2.8.1
                       cdm570LBUCDCPower 1.3.6.1.4.1.6247.24.1.2.8.1.1 integer read-write
BUC power control, where: 0 = Disable BUC DC Power 1 = Enable BUC DC Power Enumeration: 'enable': 1, 'disable': 0.
                       cdm570LBUCFSK 1.3.6.1.4.1.6247.24.1.2.8.1.2
                           cdm570LBUCComms 1.3.6.1.4.1.6247.24.1.2.8.1.2.1 integer read-write
Enables or disables communication, via the FSK link, with an externally connected Block Up Converted (BUC), where: 0 = Disabled 1 = Enabled Enumeration: 'disabled': 0, 'enabled': 1.
                           cdm570LBUCAddress 1.3.6.1.4.1.6247.24.1.2.8.1.2.2 integer read-write
Indicates the BUC address, between 1 and 15.
                           cdm570LBUCRFOutput 1.3.6.1.4.1.6247.24.1.2.8.1.2.3 integer read-write
Indicates BUC output enable, where: 0 = Off (output disabled) 1 = On (output enabled) Enumeration: 'on': 1, 'off': 0.
                       cdm570LBUC10MHzReference 1.3.6.1.4.1.6247.24.1.2.8.1.3 integer read-write
Enables or disables the 10 MHz frequency reference to the BUC, where: 0 = Disabled 1 = Enabled Enumeration: 'disabled': 0, 'enabled': 1.
                       cdm570LBUCAlarm 1.3.6.1.4.1.6247.24.1.2.8.1.4
                           cdm570LBUCHighCurrentLimit 1.3.6.1.4.1.6247.24.1.2.8.1.4.1 integer read-write
BUC high current limit, between 500 and 4000 mA.
                           cdm570LBUCLowCurrentLimit 1.3.6.1.4.1.6247.24.1.2.8.1.4.2 integer read-write
BUC low current limit, between 0 and 3000 mA. BUC low current limit must not exceed BUC high current limit.
                       cdm570LBUCLO 1.3.6.1.4.1.6247.24.1.2.8.1.5
                           cdm570LBUCLOFrequency 1.3.6.1.4.1.6247.24.1.2.8.1.5.1 integer read-write
BUC transmit LO frequency in the range of 3000 to 65000 MHz. Setting 0 disables this feature. Terminal Frequency = BUC_LO +/- Tx_Frequency (depending on LO mix).
                           cdm570LBUCLOMix 1.3.6.1.4.1.6247.24.1.2.8.1.5.2 integer read-write
BUC LO frequency mix, where: 0 = Low-side mix 1 = High-side mix Enumeration: 'lowSideMix': 0, 'highSideMix': 1.
                   cdm570LLNB 1.3.6.1.4.1.6247.24.1.2.8.2
                       cdm570LLNBDCPower 1.3.6.1.4.1.6247.24.1.2.8.2.1 integer read-write
LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage Enumeration: 'on13volts': 1, 'off': 0, 'on18volts': 2, 'on24volts': 3.
                       cdm570LLNB10MHzReference 1.3.6.1.4.1.6247.24.1.2.8.2.2 integer read-write
LNB 10MHz frequency reference, where: 0 = Disable LNB 10MHz reference 1 = Enable LNB 10MHz reference Enumeration: 'enable': 1, 'disable': 0.
                       cdm570LLNBAlarm 1.3.6.1.4.1.6247.24.1.2.8.2.3
                           cdm570LLNBHighCurrentLimit 1.3.6.1.4.1.6247.24.1.2.8.2.3.1 integer read-write
LNB upper alarm limit for current, between 50 and 600 mA.
                           cdm570LLNBLowCurrentLimit 1.3.6.1.4.1.6247.24.1.2.8.2.3.2 integer read-write
LNB lower alarm limit for current, between 10 and 400 mA.
                       cdm570LLNBLO 1.3.6.1.4.1.6247.24.1.2.8.2.4
                           cdm570LLNBLOFrequency 1.3.6.1.4.1.6247.24.1.2.8.2.4.1 integer read-write
LNB receieve LO frequency, in the range of 3000 to 65000 MHz. Setting a 0 disables the feature. Terminal Frequency = LNB_LO +/- Rx_Frequency (depending on High/Low Mix)
                           cdm570LLNBLOMix 1.3.6.1.4.1.6247.24.1.2.8.2.4.2 integer read-write
LO frequency mix, where: 0 = Low-side mix 1 = High-side mix Enumeration: 'lowSideMix': 0, 'highSideMix': 1.
                   cdm570LODUAlarms 1.3.6.1.4.1.6247.24.1.3.1.4 integer read-only
ODU Faults Value Description of status parameter 0 No ODU faults 1 BUC PLL 3 BUC current 5 BUC voltage 7 LNB current 9 LNB voltage 11 BUC temperature 13 BUC checksum Enumeration: 'bucChecksum': 13, 'noODUfaults': 0, 'bucCurrent': 3, 'bucPLL': 1, 'lnbCurrent': 7, 'bucTemperature': 11, 'bucVoltage': 5, 'lnbVoltage': 9.
                   cdm570LBUCParams 1.3.6.1.4.1.6247.24.1.3.6.1
                       cdm570LBUCCurrent 1.3.6.1.4.1.6247.24.1.3.6.1.1 integer read-only
Indicates the value of the BUC current, between 0 and 9999 mA. Units = mA.
                       cdm570LBUCVoltage 1.3.6.1.4.1.6247.24.1.3.6.1.2 integer read-only
Indicates the value ofthe BUC voltage, between 0 and 64 volts in 0.1 volts. Units = 0.1 volts.
                       cdm570LBUCTemperature 1.3.6.1.4.1.6247.24.1.3.6.1.3 integer read-only
Indicates the BUC temperature in degrees Celsius. If not available, response is -99. Note: This query is only valid when FSK and BUC power are turned On.
                       cdm570LBUCSoftwareVersion 1.3.6.1.4.1.6247.24.1.3.6.1.4 integer read-only
Indicates the BUC software version, between 1 and 15. If not available, response is 0.
                       cdm570LBUCPLLAlarm 1.3.6.1.4.1.6247.24.1.3.6.1.5 integer read-only
BUC PLL lock state, where: 0 = Locked 1 = Unlocked 9 = Unavailable Enumeration: 'locked': 0, 'unavailable': 9, 'unlocked': 1.
                       cdm570LBUCPowerLevel 1.3.6.1.4.1.6247.24.1.3.6.1.6 integer read-only
BUC output power level in 0.1 watts. Units = 0.1 watts. Returns 0 when FSK and BUC power are not enabled.
                       cdm570LBUCTerminalTxFrequency 1.3.6.1.4.1.6247.24.1.3.6.1.7 integer read-only
Terminal Tx Frequency = BUC_LO +/- Tx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if BUC LO is zero.
                   cdm570LLNBParams 1.3.6.1.4.1.6247.24.1.3.6.2
                       cdm570LLNBCurrent 1.3.6.1.4.1.6247.24.1.3.6.2.1 integer read-only
Indicates the value of the LNB current, between 0 and 999 mA.
                       cdm570LLNBVoltage 1.3.6.1.4.1.6247.24.1.3.6.2.2 integer read-only
Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0.
                       cdm570LLNBTerminalRxFrequency 1.3.6.1.4.1.6247.24.1.3.6.2.3 integer read-only
Terminal Rx frequency = LNB LO +/- Rx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if LNB_LO is zero.
       cdm570Notifications 1.3.6.1.4.1.6247.24.2
           cdm570NotificationsPrefix 1.3.6.1.4.1.6247.24.2.0
               cdm570LODUAlarm 1.3.6.1.4.1.6247.24.2.0.4
CDM-570L BUC and LNB ODU Alarm Trap
           cdm570LGroups 1.3.6.1.4.1.6247.24.3.3
               cdm570LObjectsGroup 1.3.6.1.4.1.6247.24.3.3.1
CDM-570L Objects Group.
               cdm570LNotificationsGroup 1.3.6.1.4.1.6247.24.3.3.2
CDM-570L Notifications Group.
           cdm570LCompliances 1.3.6.1.4.1.6247.24.3.4
               cdm570LCompliance 1.3.6.1.4.1.6247.24.3.4.1
CDM-570L Compliance.