CDM-570: View SNMP OID List / Download MIB
VENDOR: COMTECH EFDATA CORPORATION
Home | MIB: CDM-570 | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
cdm570 | 1.3.6.1.4.1.6247.24 |
Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems. |
||
cdm570Objects | 1.3.6.1.4.1.6247.24.1 | |||
cdm570System | 1.3.6.1.4.1.6247.24.1.1 | |||
cdm570SystemInfo | 1.3.6.1.4.1.6247.24.1.1.1 | |||
cdm570SerialNumber | 1.3.6.1.4.1.6247.24.1.1.1.1 | displaystring | read-only |
Used to query the unit 9-digit serial number. Unit returns its S/N in the form xxxxxxxxx. |
cdm570Temperature | 1.3.6.1.4.1.6247.24.1.1.1.2 | integer | read-only |
Unit returns the value of the internal temperature, in degrees Celsius. |
cdm570SystemEquipmentID | 1.3.6.1.4.1.6247.24.1.1.2 | |||
cdm570TurboOption | 1.3.6.1.4.1.6247.24.1.1.2.1 | integer | read-only |
Turbo option, where: 0 = None 1 = Turbo 2 = TPC/LDPC Enumeration: 'turbo': 1, 'none': 0, 'tpcLdpc': 2. |
cdm570ModelNumber | 1.3.6.1.4.1.6247.24.1.1.2.2 | integer | read-only |
Modem model number. |
cdm570DataRateOption | 1.3.6.1.4.1.6247.24.1.1.2.3 | integer | read-only |
Data rate option, where: 0 = Base (512 kbps) 1 = Up to 2048 kbps 2 = Up to 5000 kbps 3 = Up to 9980 kbps Enumeration: 'base512kbps': 0, 'upto5000kbps': 2, 'upto9980kbps': 3, 'upto2048kbps': 1. |
cdm570HigherOrderModulation | 1.3.6.1.4.1.6247.24.1.1.2.4 | integer | read-only |
Higer order modulation, where: 0 = None 1 = 8-PSK/8-QAM 2 = 16-QAM 3 = 8-PSK/8-QAM and 16-QAM Enumeration: 'modulation16QAM': 2, 'none': 0, 'modulation8PSK8QAM': 1, 'modulation8PSK8QAM16QAM': 3. |
cdm570IPOption | 1.3.6.1.4.1.6247.24.1.1.2.5 | integer | read-only |
IP Controller card, where: 0 = None 1 = Installed Enumeration: 'none': 0, 'installed': 1. |
cdm570RSCodecOption | 1.3.6.1.4.1.6247.24.1.1.2.6 | integer | read-only |
RS Codec Option, where: 0 = None 1 = Installed Enumeration: 'none': 0, 'installed': 1. |
cdm570SystemFirmware | 1.3.6.1.4.1.6247.24.1.1.3 | |||
cdm570FirmwareRevision | 1.3.6.1.4.1.6247.24.1.1.3.1 | displaystring | read-only |
Unit returns the value of the internal software revision installed in the unit, in the form of: Boot: XXXXXX Bulk1: YYYYYY Bulk2: ZZZZZZ, where: XXXXXX = software version of boot YYYYYY = software version of bulk1 ZZZZZZ = software version of bulk2 |
cdm570Config | 1.3.6.1.4.1.6247.24.1.2 | |||
cdm570EthernetRemoteControl | 1.3.6.1.4.1.6247.24.1.2.1 | |||
cdm570IpAddress | 1.3.6.1.4.1.6247.24.1.2.1.1 | ipaddress | read-write |
The IP address for the 10/100 BaseTx Ethernet management port. |
cdm570IpSubnetMask | 1.3.6.1.4.1.6247.24.1.2.1.2 | integer | read-write |
The network prefix length for the 10/100 BaseTx Ethernet management port. |
cdm570DefaultGateway | 1.3.6.1.4.1.6247.24.1.2.1.3 | ipaddress | read-write |
The IP address of the default gateway. |
cdm570MacAddress | 1.3.6.1.4.1.6247.24.1.2.1.4 | macaddress | read-only |
The MAC address of the Ethernet interface. |
cdm570AccessLists | 1.3.6.1.4.1.6247.24.1.2.1.5 | |||
cdm570AccessListEnforcement | 1.3.6.1.4.1.6247.24.1.2.1.5.1 | integer | read-write |
Enable or disable enforcement of the the access list. Note: Be sure that you have added the SNMP browser's/manager's IP Address to the access list before enabling access list filtering. Otherwise, the SNMP browser/manager will no longer be able to gain access to the unit. Enumeration: 'disabled': 0, 'enabled': 1. |
cdm570AccessListTable | 1.3.6.1.4.1.6247.24.1.2.1.5.2 | no-access |
The table that holds the access list. |
|
1.3.6.1.4.1.6247.24.1.2.1.5.2.1 | no-access |
The entry for the access list table. |
||
cdm570AccessListIndex | 1.3.6.1.4.1.6247.24.1.2.1.5.2.1.1 | integer | read-only |
The index for the access list from 1..4. |
cdm570AccessIPAddress | 1.3.6.1.4.1.6247.24.1.2.1.5.2.1.2 | ipaddress | read-write |
The IP addresses that can access the unit. The value of 0.0.0.0 means not defined. |
cdm570AccessSubnetMaskLength | 1.3.6.1.4.1.6247.24.1.2.1.5.2.1.3 | integer | read-write |
The subnet mask length of the IP address for the access list. Subnet mask can be from 8..32. The value of 0 means not defined. |
cdm570SNMP | 1.3.6.1.4.1.6247.24.1.2.1.6 | |||
cdm570SNMPTrapDestinationIpAddress1 | 1.3.6.1.4.1.6247.24.1.2.1.6.1 | ipaddress | read-write |
The IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a SNMP manager or browser. |
cdm570SNMPTrapDestinationIpAddress2 | 1.3.6.1.4.1.6247.24.1.2.1.6.2 | ipaddress | read-write |
The IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a SNMP manager or browser. |
cdm570SNMPTrapCommunity | 1.3.6.1.4.1.6247.24.1.2.1.6.3 | displaystring | read-write |
The community that will be included in SNMP notifications (traps) that are sent from unit. |
cdm570SNMPTrapVersion | 1.3.6.1.4.1.6247.24.1.2.1.6.4 | integer | read-write |
The SNMP version that will be used when sending traps from the unit. SNMPv1 will send V1 traps. SNMPv2 will send V2 notifications. Enumeration: 'snmpV1': 1, 'snmpV2': 2. |
cdm570Tx | 1.3.6.1.4.1.6247.24.1.2.2 | |||
cdm570TxFrequency | 1.3.6.1.4.1.6247.24.1.2.2.1 | integer | read-write |
Transmit frequency for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modems. L-Band is 950 MHz to 1950 MHz. IF-Band is 50 MHz to 90 MHz and 100 MHz to 180 MHz. Units = Hz. Resolution = 100 Hz. |
cdm570TxDataRate | 1.3.6.1.4.1.6247.24.1.2.2.2 | integer | read-write |
Tx data rate in bps (Varies based on chart below.) Units = bps Resolution = 1 bps FEC Type Modulation Code Rate Data Rate High Rate -------- ----------- ---------- --------------------- --------- None BPSK Uncoded 4.8 kbps to 3.0 Mbps None QPSK/OQPSK Uncoded 9.6 kbps to 5.0 Mbps Viterbi BPSK Rate 1/2 2.4 kbps to 1.5 Mbps Viterbi QPSK/OQPSK Rate 1/2 4.8 kbps to 3.0 Mbps Viterbi QPSK/OQPSK Rate 3/4 7.2 kbps to 4.5 Mbps Viterbi QPSK/OQPSK Rate 7/8 8.4 kbps to 5.0 Mbps Vit + RS BPSK Rate 1/2 2.4 kbps to 1.363 Mbps Vit + RS QPSK/OQPSK Rate 1/2 4.3 kbps to 2.727 Mbps Vit + RS QPSK/OQPSK Rate 3/4 6.5 kbps to 4.091 Mbps Vit + RS QPSK/OQPSK Rate 7/8 7.5 kbps to 4.666 Mbps Vit + RS 16-QAM Rate 3/4 13.0 kbps to 4.0 Mbps Vit + RS 16-QAM Rate 7/8 16.8 kbps to 4.666 Mbps TCM + RS 8-PSK Rate 2/3 8.7 kbps to 4.4 Mbps Turbo BPSK Rate 5/16 2.4 kbps to 0.937 Mbps Turbo BPSK Rate 21/44 2.4 kbps to 1.430 Mbps Turbo QPSK/OQPSK Rate 21/44 4.8 kbps to 2.860 Mbps Turbo QPSK/OQPSK Rate 3/4 7.2 kbps to 4.5 Mbps N/A Turbo QPSK/OQPSK Rate 7/8 8.4 kbps to 5.0 Mbps 5.25 Mbps Turbo QPSK/OQPSK Rate 0.95 9.1 kbps to 5.0 Mbps 5.667 Mbps Turbo 8-PSK/8-QAM Rate 3/4 10.8 kbps to 5.0 Mbps 6.75 Mbps Turbo 8-PSK/Q-QAM Rate 7/8 13.6 kbps to 5.0 Mbps 7.875 Mbps Turbo 8-PSK/Q-QAM Rate 0.95 15.3 kbps to 5.0 Mbps 8.5 Mbps Turbo 16-QAM Rate 3/4 14.4 kbps to 5.0 Mbps 9.0 Mbps Turbo 16-QAM Rate 7/8 16.8 kbps to 5.0 Mbps 9.98 Mbps |
cdm570TxFECCodeRate | 1.3.6.1.4.1.6247.24.1.2.2.3 | integer | read-write |
Transmit code rate, where 0 = Rate 5/16 (Turbo only) 1 = Rate 22/44 (Turbo only) 2 = Rate 1/2 3 = Rate 2/3 (8-PSK TCM or 16-QAM only) 4 = Rate 3/4 5 = Rate 7/8 6 = Rate 0.95 (Turbo only) 7 = Rate 1/1 (Uncoded or No FEC) Enumeration: 'rate78': 5, 'rate23': 3, 'rate34': 4, 'uncoded': 7, 'rate516': 0, 'rate12': 2, 'rate2144': 1, 'rate095': 6. |
cdm570TxModType | 1.3.6.1.4.1.6247.24.1.2.2.4 | integer | read-write |
Transmit modulation type, where: 0 = BPSK 1 = QPSK 2 = OQPSK 3 = 8-PSK 4 = 16-QAM (Turbo or Viterbi + RS only) 5 = 8-QAM Depending on FEC type, not all of these selections will be valid. Enumeration: 'mod8PSK': 3, 'modBPSK': 0, 'modQPSK': 1, 'mod16QAM': 4, 'modOQPSK': 2, 'mod8QAM': 5. |
cdm570TxFECType | 1.3.6.1.4.1.6247.24.1.2.2.5 | integer | read-write |
Transmit FEC type where: 0 = Uncoded 1 = Viterbi 2 = Viterbit + Reed-Solomon 5 = TCM + Reed-Solomon (Code Rate = 2/3) 6 = Turbo 7 = TPC/LDPC Depending on hardware, not all of these selections will be valid. Enumeration: 'turbo': 6, 'uncoded': 0, 'viterbi': 1, 'viterbiReedSolomon': 2, 'tpcLdpc': 7, 'tcmReedSolomon': 5. |
cdm570TxSpectrumInvert | 1.3.6.1.4.1.6247.24.1.2.2.6 | integer | read-write |
Transmit spectrum invert selection, where: 0 = Normal 1 = Transmit spectrum inverted Enumeration: 'inverted': 1, 'normal': 0. |
cdm570TxDataInvert | 1.3.6.1.4.1.6247.24.1.2.2.7 | integer | read-write |
Invert transmit data, where: 0 = Normal 1 = Inverted Enumeration: 'inverted': 1, 'normal': 0. |
cdm570TxClockSource | 1.3.6.1.4.1.6247.24.1.2.2.8 | integer | read-write |
Transmit clock source, where: 0 = Internal 1 = Tx Terrestrial 2 = Loop-Timed Enumeration: 'txTerrestrial': 1, 'internal': 0, 'loopTimed': 2. |
cdm570TxScrambler | 1.3.6.1.4.1.6247.24.1.2.2.9 | integer | read-write |
Transmit scrambler state, where: 0 = Off 1 = On (Default scrambler type) 2 = On = IESS-315 (Turbo only) Enumeration: 'off': 0, 'onIESS315': 2, 'onDefaul': 1. |
cdm570TxPowerLevel | 1.3.6.1.4.1.6247.24.1.2.2.10 | integer | read-write |
Transmit output power level for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modem. CDM-570L power level is between -40 and 0 dBm. CDM-570 power level is between -25 and 0 dBm. Units = 0.1 dBm |
cdm570TxCarrierState | 1.3.6.1.4.1.6247.24.1.2.2.11 | integer | read-write |
Transmit carrier state, where: 0 = Off 1 = On 2 = RTI (Receive/Transmit Inhibit) The following values are query only: 3 = External Control (read only) 4 = BUC warm-up delay (read only) 5 = STDMA Burst (ready only) Enumeration: 'on': 1, 'off': 0, 'stdmaBurstReadOnly': 5, 'rxTxInhibit': 2, 'bucWarmUpDelayReadOnly': 4, 'externalControlReadOnly': 3. |
cdm570TxSymbolRate | 1.3.6.1.4.1.6247.24.1.2.2.12 | integer | read-only |
Tx symbol rate in symbols per second (sps) Units = symbols per second (sps) Resolution = 1 sps |
cdm570Rx | 1.3.6.1.4.1.6247.24.1.2.3 | |||
cdm570RxFrequency | 1.3.6.1.4.1.6247.24.1.2.3.1 | integer | read-write |
Receive frequency for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modems. L-Band is 950 MHz to 1950 MHz. IF-Band is 50 MHz to 90 MHz and 100 MHz to 180 MHz. Units = Hz. Resolution = 100 Hz. |
cdm570RxDataRate | 1.3.6.1.4.1.6247.24.1.2.3.2 | integer | read-write |
Rx data rate in bps (Varies based on chart below.) Units = bps Resolution = 1 bps FEC Type Modulation Code Rate Data Rate High Rate -------- ----------- ---------- --------------------- --------- None BPSK Uncoded 4.8 kbps to 3.0 Mbps None QPSK/OQPSK Uncoded 9.6 kbps to 5.0 Mbps Viterbi BPSK Rate 1/2 2.4 kbps to 1.5 Mbps Viterbi QPSK/OQPSK Rate 1/2 4.8 kbps to 3.0 Mbps Viterbi QPSK/OQPSK Rate 3/4 7.2 kbps to 4.5 Mbps Viterbi QPSK/OQPSK Rate 7/8 8.4 kbps to 5.0 Mbps Vit + RS BPSK Rate 1/2 2.4 kbps to 1.363 Mbps Vit + RS QPSK/OQPSK Rate 1/2 4.3 kbps to 2.727 Mbps Vit + RS QPSK/OQPSK Rate 3/4 6.5 kbps to 4.091 Mbps Vit + RS QPSK/OQPSK Rate 7/8 7.5 kbps to 4.666 Mbps Vit + RS 16-QAM Rate 3/4 13.0 kbps to 4.0 Mbps Vit + RS 16-QAM Rate 7/8 16.8 kbps to 4.666 Mbps TCM + RS 8-PSK Rate 2/3 8.7 kbps to 4.4 Mbps Turbo BPSK Rate 5/16 2.4 kbps to 0.937 Mbps Turbo BPSK Rate 21/44 2.4 kbps to 1.430 Mbps Turbo QPSK/OQPSK Rate 21/44 4.8 kbps to 2.860 Mbps Turbo QPSK/OQPSK Rate 3/4 7.2 kbps to 4.5 Mbps N/A Turbo QPSK/OQPSK Rate 7/8 8.4 kbps to 5.0 Mbps 5.25 Mbps Turbo QPSK/OQPSK Rate 0.95 9.1 kbps to 5.0 Mbps 5.667 Mbps Turbo 8-PSK/8-QAM Rate 3/4 10.8 kbps to 5.0 Mbps 6.75 Mbps Turbo 8-PSK/Q-QAM Rate 7/8 13.6 kbps to 5.0 Mbps 7.875 Mbps Turbo 8-PSK/Q-QAM Rate 0.95 15.3 kbps to 5.0 Mbps 8.5 Mbps Turbo 16-QAM Rate 3/4 14.4 kbps to 5.0 Mbps 9.0 Mbps Turbo 16-QAM Rate 7/8 16.8 kbps to 5.0 Mbps 9.98 Mbps |
cdm570RxFECCodeRate | 1.3.6.1.4.1.6247.24.1.2.3.3 | integer | read-write |
Rx code rate, where 0 = Rate 5/16 (Turbo only) 1 = Rate 22/44 (Turbo only) 2 = Rate 1/2 3 = Rate 2/3 (8-PSK TCM or 16-QAM only) 4 = Rate 3/4 5 = Rate 7/8 6 = Rate 0.95 (Turbo only) 7 = Rate 1/1 (Uncoded or No FEC) Enumeration: 'rate78': 5, 'rate23': 3, 'rate34': 4, 'uncoded': 7, 'rate516': 0, 'rate12': 2, 'rate2144': 1, 'rate095': 6. |
cdm570RxDemodType | 1.3.6.1.4.1.6247.24.1.2.3.4 | integer | read-write |
Rx demodulation type, where: 0 = BPSK 1 = QPSK 2 = OQPSK 3 = 8-PSK 4 = 16-QAM (Turbo or Viterbi + RS only) 5 = 8-QAM Depending on FEC type, not all of these selections will be valid. Enumeration: 'demodBPSK': 0, 'demod16QAM': 4, 'demodOQPSK': 2, 'demod8PSK': 3, 'demod8QAM': 5, 'demodQPSK': 1. |
cdm570RxFECType | 1.3.6.1.4.1.6247.24.1.2.3.5 | integer | read-write |
Rx FEC type where: 0 = Uncoded 1 = Viterbi 2 = Viterbit + Reed-Solomon 5 = TCM + Reed-Solomon (Code Rate = 2/3) 6 = Turbo 7 = TPC/LDPC Depending on hardware, not all of these selections will be valid. Enumeration: 'turbo': 6, 'uncoded': 0, 'viterbi': 1, 'viterbiReedSolomon': 2, 'tpcLdpc': 7, 'tcmReedSolomon': 5. |
cdm570RxEbNoAlarmPoint | 1.3.6.1.4.1.6247.24.1.2.3.6 | integer | read-write |
Rx Eb/No alarm point in 0.1 dB, with a range between 0.1 dB and 16 dB. Units = 0.1 dB. Resolution = 0.1 dB. |
cdm570RxSpectrumInvert | 1.3.6.1.4.1.6247.24.1.2.3.7 | integer | read-write |
Rx spectrum inversion, where: 0 = Normal 1 = Rx spectrum inverted Enumeration: 'inverted': 1, 'normal': 0. |
cdm570RxDataInvert | 1.3.6.1.4.1.6247.24.1.2.3.8 | integer | read-write |
Invert receive data, where: 0 = Normal 1 = Inverted Enumeration: 'inverted': 1, 'normal': 0. |
cdm570RxBufferSize | 1.3.6.1.4.1.6247.24.1.2.3.9 | integer | read-write |
Rx buffer size, where: 0 = Buffer disabled (Clock mode = Rx satellite) 1 = +/- 1024 bits 2 = +/- 2048 bits 3 = +/- 4096 bits 4 = +/- 8192 bits 5 = +/- 16384 bits 6 = +/- 32786 bits 7 = +/- 128 bits 8 = +/- 256 bits 9 = +/- 512 bits Enumeration: 'size512bits': 9, 'size2048bits': 2, 'size4096bits': 3, 'size256bits': 8, 'size128bits': 7, 'size8192bits': 4, 'disabled': 0, 'size16384bits': 5, 'size32786bits': 6, 'size1024bits': 1. |
cdm570RxDescrambler | 1.3.6.1.4.1.6247.24.1.2.3.10 | integer | read-write |
Rx descrambler state, where: 0 = Off 1 = On (default descrambler type) 2 = On - IESS-315 (Turbo only) Enumeration: 'off': 0, 'onIESS315': 2, 'onDefault': 1. |
cdm570RxDemodAcqSweepWidth | 1.3.6.1.4.1.6247.24.1.2.3.11 | integer | read-write |
Rx +/- acquisition sweep range of demodulator, in KHz, ranging from: +/- 1 to +/- 32 KHz (rates < 625 ksym/second) or +/- 1 to 200 KHz (rates >= 625 ksym/second). |
cdm570RxSymbolRate | 1.3.6.1.4.1.6247.24.1.2.3.12 | integer | read-only |
Rx symbol rate in symbols per second (sps) Units = symbols per second (sps) Resolution = 1 sps |
cdm570Frame | 1.3.6.1.4.1.6247.24.1.2.4 | |||
cdm570FramingMode | 1.3.6.1.4.1.6247.24.1.2.4.1 | integer | read-write |
Unit operating mode, where: 0 = Unframed 1 = EDMAC Framing 2 = EDMAC-2 Framing Enumeration: 'framingEDMAC': 1, 'unframed': 0, 'framingEDMAC2': 2. |
cdm570EDMAC | 1.3.6.1.4.1.6247.24.1.2.4.2 | |||
cdm570EDMACMode | 1.3.6.1.4.1.6247.24.1.2.4.2.1 | integer | read-write |
EDMAC mode, where: 0 = EDMAC Idle 1 = EDMAC Master 2 = EDMAC Slave Enumeration: 'slave': 2, 'idle': 0, 'master': 1. |
cdm570EDMACAddress | 1.3.6.1.4.1.6247.24.1.2.4.2.2 | integer | read-write |
For a Master, the EDMA Address is the range of addresses of distant-end units (modems or transceivers) which this unit, as the Master, will forward messages for. Only values which are integer multiples of ten are permitted. (10, 20, 30, 40, etc....) For a Slave, the EDMAC address is the address of the slave and is query only. |
cdm570AUPC | 1.3.6.1.4.1.6247.24.1.2.4.3 | |||
cdm570AUPCEnable | 1.3.6.1.4.1.6247.24.1.2.4.3.1 | integer | read-write |
AUPC mode enable/disable, where: 0 = Disable 1 = Enable Note: To enable AUPC, framing must FIRST be enabled. Enumeration: 'enable': 1, 'disable': 0. |
cdm570AUPCRemoteDemodTargetEbNo | 1.3.6.1.4.1.6247.24.1.2.4.3.2 | integer | read-write |
Target Eb/No value for remote demod, from 0.0 to 14.9 dB. Units = 0.1 dB. |
cdm570AUPCTxPowerMaxIncrease | 1.3.6.1.4.1.6247.24.1.2.4.3.3 | integer | read-write |
Max increase in Tx Power permitted, from 0 to 9 dB. Units = dB. |
cdm570AUPCActionOnMaxPower | 1.3.6.1.4.1.6247.24.1.2.4.3.4 | integer | read-write |
Defines action on max. power condition, where: 0 = No action 1 = Generate Tx alarm Enumeration: 'generateTxAlarm': 1, 'noAction': 0. |
cdm570AUPCActionOnRemoteDemodUnlock | 1.3.6.1.4.1.6247.24.1.2.4.3.5 | integer | read-write |
Defines action on remote demod unlock, where: 0 = Go to nominal power 1 = Go to max power Enumeration: 'goToMaxPower': 1, 'goToNominalPower': 0. |
cdm570Interface | 1.3.6.1.4.1.6247.24.1.2.5 | |||
cdm570DataInterface | 1.3.6.1.4.1.6247.24.1.2.5.1 | integer | read-write |
Terrestrial interface type, where: 0 = EIA-422/EIA-530 DCE 1 = V.35 DCE 2 = EIA-232 (sync) 3 = G.703 T1 AMI (forces Rx and Tx data rates to 1544 kbps) 4 = G.703 T1 B8ZS (forces Rx and Tx data rates to 1544 kbps) 5 = G.703 E1 Unbal AMI (forces Rx and Tx data rates to 2048 kbps) 6 = G.703 E1 Unbal HDB3 (forces Rx and Tx data rates to 2048 kbps) 7 = G.703 E1 Bal AMI (forces Rx and Tx data rates to 2048 kbps) 8 = G.703 E1 Bal HDB3 (forces Rx and Tx data rates to 2048 kbps) 9 = IP (Ethernet) Enumeration: 'interfaceG703E1BalHDB3': 8, 'interfaceG703T1AMI': 3, 'interfaceV35': 1, 'interfaceG703E1UnbalHDB3': 6, 'interfaceEIA232': 2, 'interfaceIP': 9, 'interfaceEIA422': 0, 'interfaceG703E1UnbalAMI': 5, 'interfaceG703T1B8ZS': 4, 'interfaceG703E1BalAMI': 7. |
cdm570RTSCTSOper | 1.3.6.1.4.1.6247.24.1.2.5.2 | |||
cdm570RTS | 1.3.6.1.4.1.6247.24.1.2.5.2.1 | integer | read-write |
Defines how RTS/CTS will operate at the main data interface, where: 0 = RTS/CTS Loop, No Action (RTS and CTS are looped, so that CTS echoes the state of RTS, but RTS does not control the ON/OFF state of the carrier) 1 = Loop, RTS controls Tx Ouput (RTS and CTS are looped, so that CTS echoes the state of RTS and RTS controls the ON/OFF state of the carrier - the modem will not bring up its TX carrier until RTS is asserted.) 2 = Ignore RTS, Assert CTS Query Only: 3 = 1:N system in use, RTS/CTS ignored Enumeration: 'loopRTSCTSNoAction': 0, 'loopRTSControlsTx': 1, 'ignoreRTSAssertCTS': 2, 'ignoreRTSCTS': 3. |
cdm570G703T1 | 1.3.6.1.4.1.6247.24.1.2.5.3 | |||
cdm570T1LineBuildOut | 1.3.6.1.4.1.6247.24.1.2.5.3.1 | integer | read-write |
Valid only for T1 interface, where: 0 = 0 - 133 feet 1 = 133 - 266 feet 2 = 266 - 399 feet 3 = 399 - 533 feet 4 = 533 - 655 feet Enumeration: 'distance399To533feet': 3, 'distance0To133feet': 0, 'distance133To266feet': 1, 'distance533To655feet': 4, 'distance266To399feet': 2. |
cdm570Reference | 1.3.6.1.4.1.6247.24.1.2.6 | |||
cdm570ReferenceFrequency | 1.3.6.1.4.1.6247.24.1.2.6.1 | integer | read-write |
External reference frequency, where: 0 = Internal 10 MHz 1 = External 1 MHz 2 = External 2 MHz 3 = External 5 MHz 4 = External 10 MHz 5 = External 20 MHz Enumeration: 'ext5MHz': 3, 'ext1MHz': 1, 'ext20MHz': 5, 'ext2MHz': 2, 'ext10MHz': 4, 'int10MHz': 0. |
cdm570AlarmMask | 1.3.6.1.4.1.6247.24.1.2.7 | |||
cdm570AlarmMaskTxFIFO | 1.3.6.1.4.1.6247.24.1.2.7.1 | integer | read-write |
Tx FIFO alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1. |
cdm570AlarmMaskG703BPV | 1.3.6.1.4.1.6247.24.1.2.7.2 | integer | read-write |
G.703 BPV alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1. |
cdm570AlarmMaskTxAIS | 1.3.6.1.4.1.6247.24.1.2.7.3 | integer | read-write |
Tx-AIS alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1. |
cdm570AlarmMaskRxAGC | 1.3.6.1.4.1.6247.24.1.2.7.4 | integer | read-write |
Rx AGC alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1. |
cdm570AlarmMaskEbNoAlarm | 1.3.6.1.4.1.6247.24.1.2.7.5 | integer | read-write |
Eb/No alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1. |
cdm570AlarmMaskRxAIS | 1.3.6.1.4.1.6247.24.1.2.7.6 | integer | read-write |
Rx-AIS alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1. |
cdm570AlarmMaskBufferSlip | 1.3.6.1.4.1.6247.24.1.2.7.7 | integer | read-write |
Buffer slip alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1. |
cdm570AlarmMaskExtReference | 1.3.6.1.4.1.6247.24.1.2.7.8 | integer | read-write |
External reference alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1. |
cdm570ODU | 1.3.6.1.4.1.6247.24.1.2.8 | |||
cdm570Monitor | 1.3.6.1.4.1.6247.24.1.3 | |||
cdm570Alarms | 1.3.6.1.4.1.6247.24.1.3.1 | |||
cdm570UnitAlarms | 1.3.6.1.4.1.6247.24.1.3.1.1 | integer | read-only |
Modem Unit Faults: Value Description of unit fault 0 No faults 1 +5 Volt power supply 2 +12 Volt power supply 3 -5 Volt power supply 4 +23 Volt power supply 5 -12 Volt power supply 6 Tx synthesizer lock 7 Rx 1st LO synthesize lock 8 Rx 2nd LO synthesize lock 9 Ref PLL lock 14 MPP50 (IP Module) Fault 15 EEPROM checksum error Enumeration: 'rx1stLOSynthesizerLock': 7, 'rx2ndLOSynthesizerLock': 8, 'powerSupply5volts': 1, 'powerSupplyNeg12volts': 5, 'txSynthesizerLock': 6, 'noFaults': 0, 'powerSupply12volts': 2, 'mpp50Fault': 14, 'refPLLLock': 9, 'powerSupply23volts': 4, 'checksumErrorEEPROM': 15, 'powerSupplyNeg5volts': 3. |
cdm570TxAlarms | 1.3.6.1.4.1.6247.24.1.3.1.2 | integer | read-only |
Modem TX Traffic Faults: Value Description of Tx Traffic status 0 Tx traffic OK 1 No clock from terrestrial interface 3 Tx FIFO slip 5 Loss of External Reference 7 AUPC upper limit reached 9 AIS Detected on incoming data 11 Bipolar violation on G.705 interface Enumeration: 'aupcUpperLimitReached': 7, 'noClockFromTerrestrialInterface': 1, 'aisDetectedOnIncomingData': 9, 'bipolarViolationOnG703Interface': 11, 'txFIFOSlip': 3, 'lostExternalReference': 5, 'txTrafficOK': 0. |
cdm570RxAlarms | 1.3.6.1.4.1.6247.24.1.3.1.3 | integer | read-only |
Modem RX Traffic Faults Value Description of status parameter 0 Rx Traffic OK 1 Demodulator unlocked 3 AGC Alarm - signal out of range 5 RS Frame sync alarm 7 EDMAC Frame sync alarm 10 Buffer underflow 11 Buffer overflow 13 Eb/No alarm 15 AIS detected on incoming data Enumeration: 'demodulatorUnlocked': 1, 'ebNoAlarm': 13, 'rxTrafficOK': 0, 'aisDetectedOnIncomingData': 15, 'agcAlarmSignalOutOfRange': 3, 'bufferOverflow': 11, 'edmacFrameSyncAlarm': 7, 'bufferUnderflow': 10, 'rsFrameSyncAlarm': 5. |
cdm570RxParams | 1.3.6.1.4.1.6247.24.1.3.2 | |||
cdm570RxBERMultiplier | 1.3.6.1.4.1.6247.24.1.3.2.1 | integer | read-only |
Estimated corrected BER. The BER is calculated by mubliplying the Multiplier by 10E-10. Calculuation: RxBER = (Multiplier) * 0.0000000001 Returns 2147483647 (max int) if demod is unlocked. |
cdm570BufferFillState | 1.3.6.1.4.1.6247.24.1.3.2.2 | integer | read-only |
Unit returns the value of the buffer fill state, between 1 to 99%. Returns 0 if demodulator is unlocked. Returns -1 if buffer is disabled. |
cdm570RxFrequencyOffset | 1.3.6.1.4.1.6247.24.1.3.2.3 | integer | read-only |
Unit returns the value of the measured frequency offset of the carrier being demodulated in Hz. Units = Hz. Resolution 100 Hz. Range = -200,000 Hz to 0 Hz and 0 Hz to 200,000 Hz. |
cdm570RxSignalLevel | 1.3.6.1.4.1.6247.24.1.3.2.4 | integer | read-only |
Unit returns the value of the Rx signal level, in dBm, between -99 dBm and -5 dBm. Returns -100 if signal is less than -99 dBm. Returns -4 if signal is greater than -5 dBm. |
cdm570RxEbNo | 1.3.6.1.4.1.6247.24.1.3.2.5 | integer | read-only |
Unit returns the value of Eb/No, between 0 and 16 db. Units = 0.1 dB. Resolution 0.1 dB. Returns 999 if demod is unlocked. For values greater than 16 dB, the reply will be 160. |
cdm570EventLog | 1.3.6.1.4.1.6247.24.1.3.3 | |||
cdm570StoredEventsTable | 1.3.6.1.4.1.6247.24.1.3.3.1 | no-access |
The table for stored events. |
|
1.3.6.1.4.1.6247.24.1.3.3.1.1 | no-access |
The entry for the stored events table. |
||
cdm570EventIndex | 1.3.6.1.4.1.6247.24.1.3.3.1.1.1 | integer | read-only |
The index for stored events table. |
cdm570EventDate | 1.3.6.1.4.1.6247.24.1.3.3.1.1.2 | displaystring | read-only |
The date of the event in the form ddmmyy, where dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) |
cdm570EventTime | 1.3.6.1.4.1.6247.24.1.3.3.1.1.3 | displaystring | read-only |
The time of the event in the form hhmmss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) |
cdm570EventDescription | 1.3.6.1.4.1.6247.24.1.3.3.1.1.4 | displaystring | read-only |
The event description string with following format: {1 of the following: Clear, Fault, Info} - {Texual Description of Event} |
cdm570ClearAllStoredEvents | 1.3.6.1.4.1.6247.24.1.3.3.2 | integer | read-write |
Forces the software to clear the event log. This is a command only. Enumeration: 'clearAll': 1. |
cdm570Statistics | 1.3.6.1.4.1.6247.24.1.3.4 | |||
cdm570StatisticsSampleInterval | 1.3.6.1.4.1.6247.24.1.3.4.1 | integer | read-write |
Used to set the sample interval for the statistics logging function, where the enumerated lists goes from 0 to 9 in 10 minute steps. Setting 0 disables the statistics logging function. Enumeration: 'mins70': 7, 'mins40': 4, 'mins50': 5, 'disabled': 0, 'mins10': 1, 'mins60': 6, 'mins80': 8, 'mins90': 9, 'mins20': 2, 'mins30': 3. |
cdm570StoredStatisticsTable | 1.3.6.1.4.1.6247.24.1.3.4.2 | no-access |
Description. |
|
1.3.6.1.4.1.6247.24.1.3.4.2.1 | no-access |
Entry for stored statistics table. |
||
cdm570StatisticIndex | 1.3.6.1.4.1.6247.24.1.3.4.2.1.1 | integer | read-only |
Index for stored statistics table. |
cdm570StatisticDate | 1.3.6.1.4.1.6247.24.1.3.4.2.1.2 | displaystring | read-only |
The date of the statistic in the form ddmmyy, where: dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) |
cdm570StatisticTime | 1.3.6.1.4.1.6247.24.1.3.4.2.1.3 | displaystring | read-only |
The time of the statistic in the form hhmmss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) |
cdm570StatisticMinEbNo | 1.3.6.1.4.1.6247.24.1.3.4.2.1.4 | integer | read-only |
Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period. |
cdm570StatisticAvgEbNo | 1.3.6.1.4.1.6247.24.1.3.4.2.1.5 | integer | read-only |
Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period. |
cdm570StatisticMaxTxPowerIncrease | 1.3.6.1.4.1.6247.24.1.3.4.2.1.6 | integer | read-only |
Max. Tx power level increase during sample period. Units = 0.1 dB |
cdm570StatisticAvgTxPowerIncrease | 1.3.6.1.4.1.6247.24.1.3.4.2.1.7 | integer | read-only |
Average Tx power level increase during sample period. Units = 0.1 dB |
cdm570ClearAllStoredStatistics | 1.3.6.1.4.1.6247.24.1.3.4.3 | integer | read-write |
Forces the software to clear the statistics log. This is a command only. Enumeration: 'clearAll': 1. |
cdm570AUPCParams | 1.3.6.1.4.1.6247.24.1.3.5 | |||
cdm570AUPCRemoteDemodEbNo | 1.3.6.1.4.1.6247.24.1.3.5.1 | integer | read-only |
Returns the value of the Eb/No ofthe remote demodulator. Units = 0.1 dB Responds 999 = remote demod unlocked. Responds 0 = EDMAC is disabled. |
cdm570AUPCTxPowerIncrease | 1.3.6.1.4.1.6247.24.1.3.5.2 | integer | read-only |
Returns the increase in Tx power level, in 0.1 dB (from the nominal setting) due to the action of AUPC. Responds with 999 if AUPC is disabled. |
cdm570ODUParams | 1.3.6.1.4.1.6247.24.1.3.6 | |||
cdm570Test | 1.3.6.1.4.1.6247.24.1.4 | |||
cdm570UnitTestMode | 1.3.6.1.4.1.6247.24.1.4.1 | integer | read-write |
Unit Test Mode where: 0 = Normal Mode 1 = IF Loopback 2 = Digital Loopback 3 = IO Loopback 4 = RF Loopback 5 = Tx CW 6 = Tx Alternating Pattern Enumeration: 'normalMode': 0, 'digitalLoopBack': 2, 'ioLoopBack': 3, 'ifLoopBack': 1, 'rfLoopback': 4, 'txCW': 5, 'txAlternatingPattern': 6. |
cdm570SaveLoad | 1.3.6.1.4.1.6247.24.1.5 | |||
cdm570ConfigurationSave | 1.3.6.1.4.1.6247.24.1.5.1 | integer | read-write |
Causes the device to store the current modem configuration in configuration memory location defined by the argument (0 to 9). This is a COMMAND ONLY. Get always responds with 0. |
cdm570ConfigurationLoad | 1.3.6.1.4.1.6247.24.1.5.2 | integer | read-write |
Causes the device to retrieve a previously stored modem configuration from configuration memory location defined by the argument (0 to 9). This is a COMMAND ONLY. Get always responds with 0. |
cdm570Util | 1.3.6.1.4.1.6247.24.1.6 | |||
cdm570Buffer | 1.3.6.1.4.1.6247.24.1.6.1 | |||
cdm570ReCenterBuffer | 1.3.6.1.4.1.6247.24.1.6.1.1 | integer | read-write |
Forces the software to recenter the receive Plesiochronous/Doppler buffer. This is a command only. Enumeration: 'reCenter': 1. |
cdm570RealTimeClock | 1.3.6.1.4.1.6247.24.1.6.2 | |||
cdm570RTCDate | 1.3.6.1.4.1.6247.24.1.6.2.1 | displaystring | read-write |
A date in the form dd/mm/yy, where dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) |
cdm570RTCTime | 1.3.6.1.4.1.6247.24.1.6.2.2 | displaystring | read-write |
A time in the form hh:mm:ss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) |
cdm570InternalReference | 1.3.6.1.4.1.6247.24.1.6.3 | |||
cdm570WarmUpDelay | 1.3.6.1.4.1.6247.24.1.6.3.2 | integer | read-write |
Warm-up delay for internal frequency reference (OCXO), where: 0 = Disabled (instant on - no delay for OCXO to reach temperature) 1 = Enabled (unit waits until OCXO reaches correct temperature) Enumeration: 'enable': 1, 'disable': 0. |
cdm570WarmUpCountdown | 1.3.6.1.4.1.6247.24.1.6.3.3 | integer | read-write |
As a query, returns the Warm-up delay countdown in seconds remaining. As a command, only takes the argument 0 and is used to truncate the warm-up delay period to zero, forcing the unit into 'instanct-on' mode. |
cdm570ID | 1.3.6.1.4.1.6247.24.1.6.4 | |||
cdm570CircuitID | 1.3.6.1.4.1.6247.24.1.6.4.1 | displaystring | read-write |
Sets or queries the user-defined Circuit ID string, which is a fixed length of 24 characters. Valid characters include: Space ( ) * + - , . / 0 thru 9 and A thru Z |
cdm570Redundancy | 1.3.6.1.4.1.6247.24.1.6.5 | |||
cdm570RedundancyState | 1.3.6.1.4.1.6247.24.1.6.5.1 | integer | read-only |
Unit returns the redundancy state of the unit, where: 0 = Offline 1 = Online Enumeration: 'offline': 0, 'online': 1. |
cdm570ForceRedundentSwitch | 1.3.6.1.4.1.6247.24.1.6.5.2 | integer | read-write |
Force redundundent switch command. Enumeration: 'forceSwitch': 1. |
cdm570ODUComms | 1.3.6.1.4.1.6247.24.1.6.6 | |||
cdm570ODUCommsEnabled | 1.3.6.1.4.1.6247.24.1.6.6.1 | integer | read-write |
ODU Comms, where 0 = Disabled 1 = Enabled Enumeration: 'disabled': 0, 'enabled': 1. |
cdm570Notifications | 1.3.6.1.4.1.6247.24.2 | |||
cdm570NotificationsPrefix | 1.3.6.1.4.1.6247.24.2.0 | |||
cdm570UnitAlarm | 1.3.6.1.4.1.6247.24.2.0.1 |
Modem Unit Faults Trap |
||
cdm570TxTrafficAlarm | 1.3.6.1.4.1.6247.24.2.0.2 |
Modem TX Traffic Faults Trap |
||
cdm570RxTrafficAlarm | 1.3.6.1.4.1.6247.24.2.0.3 |
Modem RX Traffic Faults Trap |
||
cdm570Conformance | 1.3.6.1.4.1.6247.24.3 | |||
cdm570Groups | 1.3.6.1.4.1.6247.24.3.1 | |||
cdm570ObjectsGroup | 1.3.6.1.4.1.6247.24.3.1.1 |
CDM-570 (Both L-Band and IF-Band) Objects Group. |
||
cdm570NotificationsGroup | 1.3.6.1.4.1.6247.24.3.1.2 |
CDM-570 (Both L-Band and IF-Band) Notifications Group. |
||
cdm570Compliances | 1.3.6.1.4.1.6247.24.3.2 | |||
cdm570Compliance | 1.3.6.1.4.1.6247.24.3.2.1 |
CDM-570 (Both L-Band and IF-Band) Compliance. |