CDM-570: View SNMP OID List / Download MIB

VENDOR: COMTECH EFDATA CORPORATION


 Home MIB: CDM-570
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 cdm570 1.3.6.1.4.1.6247.24
Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems.
       cdm570Objects 1.3.6.1.4.1.6247.24.1
           cdm570System 1.3.6.1.4.1.6247.24.1.1
               cdm570SystemInfo 1.3.6.1.4.1.6247.24.1.1.1
                   cdm570SerialNumber 1.3.6.1.4.1.6247.24.1.1.1.1 displaystring read-only
Used to query the unit 9-digit serial number. Unit returns its S/N in the form xxxxxxxxx.
                   cdm570Temperature 1.3.6.1.4.1.6247.24.1.1.1.2 integer read-only
Unit returns the value of the internal temperature, in degrees Celsius.
               cdm570SystemEquipmentID 1.3.6.1.4.1.6247.24.1.1.2
                   cdm570TurboOption 1.3.6.1.4.1.6247.24.1.1.2.1 integer read-only
Turbo option, where: 0 = None 1 = Turbo 2 = TPC/LDPC Enumeration: 'turbo': 1, 'none': 0, 'tpcLdpc': 2.
                   cdm570ModelNumber 1.3.6.1.4.1.6247.24.1.1.2.2 integer read-only
Modem model number.
                   cdm570DataRateOption 1.3.6.1.4.1.6247.24.1.1.2.3 integer read-only
Data rate option, where: 0 = Base (512 kbps) 1 = Up to 2048 kbps 2 = Up to 5000 kbps 3 = Up to 9980 kbps Enumeration: 'base512kbps': 0, 'upto5000kbps': 2, 'upto9980kbps': 3, 'upto2048kbps': 1.
                   cdm570HigherOrderModulation 1.3.6.1.4.1.6247.24.1.1.2.4 integer read-only
Higer order modulation, where: 0 = None 1 = 8-PSK/8-QAM 2 = 16-QAM 3 = 8-PSK/8-QAM and 16-QAM Enumeration: 'modulation16QAM': 2, 'none': 0, 'modulation8PSK8QAM': 1, 'modulation8PSK8QAM16QAM': 3.
                   cdm570IPOption 1.3.6.1.4.1.6247.24.1.1.2.5 integer read-only
IP Controller card, where: 0 = None 1 = Installed Enumeration: 'none': 0, 'installed': 1.
                   cdm570RSCodecOption 1.3.6.1.4.1.6247.24.1.1.2.6 integer read-only
RS Codec Option, where: 0 = None 1 = Installed Enumeration: 'none': 0, 'installed': 1.
               cdm570SystemFirmware 1.3.6.1.4.1.6247.24.1.1.3
                   cdm570FirmwareRevision 1.3.6.1.4.1.6247.24.1.1.3.1 displaystring read-only
Unit returns the value of the internal software revision installed in the unit, in the form of: Boot: XXXXXX Bulk1: YYYYYY Bulk2: ZZZZZZ, where: XXXXXX = software version of boot YYYYYY = software version of bulk1 ZZZZZZ = software version of bulk2
           cdm570Config 1.3.6.1.4.1.6247.24.1.2
               cdm570EthernetRemoteControl 1.3.6.1.4.1.6247.24.1.2.1
                   cdm570IpAddress 1.3.6.1.4.1.6247.24.1.2.1.1 ipaddress read-write
The IP address for the 10/100 BaseTx Ethernet management port.
                   cdm570IpSubnetMask 1.3.6.1.4.1.6247.24.1.2.1.2 integer read-write
The network prefix length for the 10/100 BaseTx Ethernet management port.
                   cdm570DefaultGateway 1.3.6.1.4.1.6247.24.1.2.1.3 ipaddress read-write
The IP address of the default gateway.
                   cdm570MacAddress 1.3.6.1.4.1.6247.24.1.2.1.4 macaddress read-only
The MAC address of the Ethernet interface.
                   cdm570AccessLists 1.3.6.1.4.1.6247.24.1.2.1.5
                       cdm570AccessListEnforcement 1.3.6.1.4.1.6247.24.1.2.1.5.1 integer read-write
Enable or disable enforcement of the the access list. Note: Be sure that you have added the SNMP browser's/manager's IP Address to the access list before enabling access list filtering. Otherwise, the SNMP browser/manager will no longer be able to gain access to the unit. Enumeration: 'disabled': 0, 'enabled': 1.
                       cdm570AccessListTable 1.3.6.1.4.1.6247.24.1.2.1.5.2 no-access
The table that holds the access list.
                           cdm570AccessListEntry 1.3.6.1.4.1.6247.24.1.2.1.5.2.1 no-access
The entry for the access list table.
                               cdm570AccessListIndex 1.3.6.1.4.1.6247.24.1.2.1.5.2.1.1 integer read-only
The index for the access list from 1..4.
                               cdm570AccessIPAddress 1.3.6.1.4.1.6247.24.1.2.1.5.2.1.2 ipaddress read-write
The IP addresses that can access the unit. The value of 0.0.0.0 means not defined.
                               cdm570AccessSubnetMaskLength 1.3.6.1.4.1.6247.24.1.2.1.5.2.1.3 integer read-write
The subnet mask length of the IP address for the access list. Subnet mask can be from 8..32. The value of 0 means not defined.
                   cdm570SNMP 1.3.6.1.4.1.6247.24.1.2.1.6
                       cdm570SNMPTrapDestinationIpAddress1 1.3.6.1.4.1.6247.24.1.2.1.6.1 ipaddress read-write
The IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a SNMP manager or browser.
                       cdm570SNMPTrapDestinationIpAddress2 1.3.6.1.4.1.6247.24.1.2.1.6.2 ipaddress read-write
The IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a SNMP manager or browser.
                       cdm570SNMPTrapCommunity 1.3.6.1.4.1.6247.24.1.2.1.6.3 displaystring read-write
The community that will be included in SNMP notifications (traps) that are sent from unit.
                       cdm570SNMPTrapVersion 1.3.6.1.4.1.6247.24.1.2.1.6.4 integer read-write
The SNMP version that will be used when sending traps from the unit. SNMPv1 will send V1 traps. SNMPv2 will send V2 notifications. Enumeration: 'snmpV1': 1, 'snmpV2': 2.
               cdm570Tx 1.3.6.1.4.1.6247.24.1.2.2
                   cdm570TxFrequency 1.3.6.1.4.1.6247.24.1.2.2.1 integer read-write
Transmit frequency for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modems. L-Band is 950 MHz to 1950 MHz. IF-Band is 50 MHz to 90 MHz and 100 MHz to 180 MHz. Units = Hz. Resolution = 100 Hz.
                   cdm570TxDataRate 1.3.6.1.4.1.6247.24.1.2.2.2 integer read-write
Tx data rate in bps (Varies based on chart below.) Units = bps Resolution = 1 bps FEC Type Modulation Code Rate Data Rate High Rate -------- ----------- ---------- --------------------- --------- None BPSK Uncoded 4.8 kbps to 3.0 Mbps None QPSK/OQPSK Uncoded 9.6 kbps to 5.0 Mbps Viterbi BPSK Rate 1/2 2.4 kbps to 1.5 Mbps Viterbi QPSK/OQPSK Rate 1/2 4.8 kbps to 3.0 Mbps Viterbi QPSK/OQPSK Rate 3/4 7.2 kbps to 4.5 Mbps Viterbi QPSK/OQPSK Rate 7/8 8.4 kbps to 5.0 Mbps Vit + RS BPSK Rate 1/2 2.4 kbps to 1.363 Mbps Vit + RS QPSK/OQPSK Rate 1/2 4.3 kbps to 2.727 Mbps Vit + RS QPSK/OQPSK Rate 3/4 6.5 kbps to 4.091 Mbps Vit + RS QPSK/OQPSK Rate 7/8 7.5 kbps to 4.666 Mbps Vit + RS 16-QAM Rate 3/4 13.0 kbps to 4.0 Mbps Vit + RS 16-QAM Rate 7/8 16.8 kbps to 4.666 Mbps TCM + RS 8-PSK Rate 2/3 8.7 kbps to 4.4 Mbps Turbo BPSK Rate 5/16 2.4 kbps to 0.937 Mbps Turbo BPSK Rate 21/44 2.4 kbps to 1.430 Mbps Turbo QPSK/OQPSK Rate 21/44 4.8 kbps to 2.860 Mbps Turbo QPSK/OQPSK Rate 3/4 7.2 kbps to 4.5 Mbps N/A Turbo QPSK/OQPSK Rate 7/8 8.4 kbps to 5.0 Mbps 5.25 Mbps Turbo QPSK/OQPSK Rate 0.95 9.1 kbps to 5.0 Mbps 5.667 Mbps Turbo 8-PSK/8-QAM Rate 3/4 10.8 kbps to 5.0 Mbps 6.75 Mbps Turbo 8-PSK/Q-QAM Rate 7/8 13.6 kbps to 5.0 Mbps 7.875 Mbps Turbo 8-PSK/Q-QAM Rate 0.95 15.3 kbps to 5.0 Mbps 8.5 Mbps Turbo 16-QAM Rate 3/4 14.4 kbps to 5.0 Mbps 9.0 Mbps Turbo 16-QAM Rate 7/8 16.8 kbps to 5.0 Mbps 9.98 Mbps
                   cdm570TxFECCodeRate 1.3.6.1.4.1.6247.24.1.2.2.3 integer read-write
Transmit code rate, where 0 = Rate 5/16 (Turbo only) 1 = Rate 22/44 (Turbo only) 2 = Rate 1/2 3 = Rate 2/3 (8-PSK TCM or 16-QAM only) 4 = Rate 3/4 5 = Rate 7/8 6 = Rate 0.95 (Turbo only) 7 = Rate 1/1 (Uncoded or No FEC) Enumeration: 'rate78': 5, 'rate23': 3, 'rate34': 4, 'uncoded': 7, 'rate516': 0, 'rate12': 2, 'rate2144': 1, 'rate095': 6.
                   cdm570TxModType 1.3.6.1.4.1.6247.24.1.2.2.4 integer read-write
Transmit modulation type, where: 0 = BPSK 1 = QPSK 2 = OQPSK 3 = 8-PSK 4 = 16-QAM (Turbo or Viterbi + RS only) 5 = 8-QAM Depending on FEC type, not all of these selections will be valid. Enumeration: 'mod8PSK': 3, 'modBPSK': 0, 'modQPSK': 1, 'mod16QAM': 4, 'modOQPSK': 2, 'mod8QAM': 5.
                   cdm570TxFECType 1.3.6.1.4.1.6247.24.1.2.2.5 integer read-write
Transmit FEC type where: 0 = Uncoded 1 = Viterbi 2 = Viterbit + Reed-Solomon 5 = TCM + Reed-Solomon (Code Rate = 2/3) 6 = Turbo 7 = TPC/LDPC Depending on hardware, not all of these selections will be valid. Enumeration: 'turbo': 6, 'uncoded': 0, 'viterbi': 1, 'viterbiReedSolomon': 2, 'tpcLdpc': 7, 'tcmReedSolomon': 5.
                   cdm570TxSpectrumInvert 1.3.6.1.4.1.6247.24.1.2.2.6 integer read-write
Transmit spectrum invert selection, where: 0 = Normal 1 = Transmit spectrum inverted Enumeration: 'inverted': 1, 'normal': 0.
                   cdm570TxDataInvert 1.3.6.1.4.1.6247.24.1.2.2.7 integer read-write
Invert transmit data, where: 0 = Normal 1 = Inverted Enumeration: 'inverted': 1, 'normal': 0.
                   cdm570TxClockSource 1.3.6.1.4.1.6247.24.1.2.2.8 integer read-write
Transmit clock source, where: 0 = Internal 1 = Tx Terrestrial 2 = Loop-Timed Enumeration: 'txTerrestrial': 1, 'internal': 0, 'loopTimed': 2.
                   cdm570TxScrambler 1.3.6.1.4.1.6247.24.1.2.2.9 integer read-write
Transmit scrambler state, where: 0 = Off 1 = On (Default scrambler type) 2 = On = IESS-315 (Turbo only) Enumeration: 'off': 0, 'onIESS315': 2, 'onDefaul': 1.
                   cdm570TxPowerLevel 1.3.6.1.4.1.6247.24.1.2.2.10 integer read-write
Transmit output power level for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modem. CDM-570L power level is between -40 and 0 dBm. CDM-570 power level is between -25 and 0 dBm. Units = 0.1 dBm
                   cdm570TxCarrierState 1.3.6.1.4.1.6247.24.1.2.2.11 integer read-write
Transmit carrier state, where: 0 = Off 1 = On 2 = RTI (Receive/Transmit Inhibit) The following values are query only: 3 = External Control (read only) 4 = BUC warm-up delay (read only) 5 = STDMA Burst (ready only) Enumeration: 'on': 1, 'off': 0, 'stdmaBurstReadOnly': 5, 'rxTxInhibit': 2, 'bucWarmUpDelayReadOnly': 4, 'externalControlReadOnly': 3.
                   cdm570TxSymbolRate 1.3.6.1.4.1.6247.24.1.2.2.12 integer read-only
Tx symbol rate in symbols per second (sps) Units = symbols per second (sps) Resolution = 1 sps
               cdm570Rx 1.3.6.1.4.1.6247.24.1.2.3
                   cdm570RxFrequency 1.3.6.1.4.1.6247.24.1.2.3.1 integer read-write
Receive frequency for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modems. L-Band is 950 MHz to 1950 MHz. IF-Band is 50 MHz to 90 MHz and 100 MHz to 180 MHz. Units = Hz. Resolution = 100 Hz.
                   cdm570RxDataRate 1.3.6.1.4.1.6247.24.1.2.3.2 integer read-write
Rx data rate in bps (Varies based on chart below.) Units = bps Resolution = 1 bps FEC Type Modulation Code Rate Data Rate High Rate -------- ----------- ---------- --------------------- --------- None BPSK Uncoded 4.8 kbps to 3.0 Mbps None QPSK/OQPSK Uncoded 9.6 kbps to 5.0 Mbps Viterbi BPSK Rate 1/2 2.4 kbps to 1.5 Mbps Viterbi QPSK/OQPSK Rate 1/2 4.8 kbps to 3.0 Mbps Viterbi QPSK/OQPSK Rate 3/4 7.2 kbps to 4.5 Mbps Viterbi QPSK/OQPSK Rate 7/8 8.4 kbps to 5.0 Mbps Vit + RS BPSK Rate 1/2 2.4 kbps to 1.363 Mbps Vit + RS QPSK/OQPSK Rate 1/2 4.3 kbps to 2.727 Mbps Vit + RS QPSK/OQPSK Rate 3/4 6.5 kbps to 4.091 Mbps Vit + RS QPSK/OQPSK Rate 7/8 7.5 kbps to 4.666 Mbps Vit + RS 16-QAM Rate 3/4 13.0 kbps to 4.0 Mbps Vit + RS 16-QAM Rate 7/8 16.8 kbps to 4.666 Mbps TCM + RS 8-PSK Rate 2/3 8.7 kbps to 4.4 Mbps Turbo BPSK Rate 5/16 2.4 kbps to 0.937 Mbps Turbo BPSK Rate 21/44 2.4 kbps to 1.430 Mbps Turbo QPSK/OQPSK Rate 21/44 4.8 kbps to 2.860 Mbps Turbo QPSK/OQPSK Rate 3/4 7.2 kbps to 4.5 Mbps N/A Turbo QPSK/OQPSK Rate 7/8 8.4 kbps to 5.0 Mbps 5.25 Mbps Turbo QPSK/OQPSK Rate 0.95 9.1 kbps to 5.0 Mbps 5.667 Mbps Turbo 8-PSK/8-QAM Rate 3/4 10.8 kbps to 5.0 Mbps 6.75 Mbps Turbo 8-PSK/Q-QAM Rate 7/8 13.6 kbps to 5.0 Mbps 7.875 Mbps Turbo 8-PSK/Q-QAM Rate 0.95 15.3 kbps to 5.0 Mbps 8.5 Mbps Turbo 16-QAM Rate 3/4 14.4 kbps to 5.0 Mbps 9.0 Mbps Turbo 16-QAM Rate 7/8 16.8 kbps to 5.0 Mbps 9.98 Mbps
                   cdm570RxFECCodeRate 1.3.6.1.4.1.6247.24.1.2.3.3 integer read-write
Rx code rate, where 0 = Rate 5/16 (Turbo only) 1 = Rate 22/44 (Turbo only) 2 = Rate 1/2 3 = Rate 2/3 (8-PSK TCM or 16-QAM only) 4 = Rate 3/4 5 = Rate 7/8 6 = Rate 0.95 (Turbo only) 7 = Rate 1/1 (Uncoded or No FEC) Enumeration: 'rate78': 5, 'rate23': 3, 'rate34': 4, 'uncoded': 7, 'rate516': 0, 'rate12': 2, 'rate2144': 1, 'rate095': 6.
                   cdm570RxDemodType 1.3.6.1.4.1.6247.24.1.2.3.4 integer read-write
Rx demodulation type, where: 0 = BPSK 1 = QPSK 2 = OQPSK 3 = 8-PSK 4 = 16-QAM (Turbo or Viterbi + RS only) 5 = 8-QAM Depending on FEC type, not all of these selections will be valid. Enumeration: 'demodBPSK': 0, 'demod16QAM': 4, 'demodOQPSK': 2, 'demod8PSK': 3, 'demod8QAM': 5, 'demodQPSK': 1.
                   cdm570RxFECType 1.3.6.1.4.1.6247.24.1.2.3.5 integer read-write
Rx FEC type where: 0 = Uncoded 1 = Viterbi 2 = Viterbit + Reed-Solomon 5 = TCM + Reed-Solomon (Code Rate = 2/3) 6 = Turbo 7 = TPC/LDPC Depending on hardware, not all of these selections will be valid. Enumeration: 'turbo': 6, 'uncoded': 0, 'viterbi': 1, 'viterbiReedSolomon': 2, 'tpcLdpc': 7, 'tcmReedSolomon': 5.
                   cdm570RxEbNoAlarmPoint 1.3.6.1.4.1.6247.24.1.2.3.6 integer read-write
Rx Eb/No alarm point in 0.1 dB, with a range between 0.1 dB and 16 dB. Units = 0.1 dB. Resolution = 0.1 dB.
                   cdm570RxSpectrumInvert 1.3.6.1.4.1.6247.24.1.2.3.7 integer read-write
Rx spectrum inversion, where: 0 = Normal 1 = Rx spectrum inverted Enumeration: 'inverted': 1, 'normal': 0.
                   cdm570RxDataInvert 1.3.6.1.4.1.6247.24.1.2.3.8 integer read-write
Invert receive data, where: 0 = Normal 1 = Inverted Enumeration: 'inverted': 1, 'normal': 0.
                   cdm570RxBufferSize 1.3.6.1.4.1.6247.24.1.2.3.9 integer read-write
Rx buffer size, where: 0 = Buffer disabled (Clock mode = Rx satellite) 1 = +/- 1024 bits 2 = +/- 2048 bits 3 = +/- 4096 bits 4 = +/- 8192 bits 5 = +/- 16384 bits 6 = +/- 32786 bits 7 = +/- 128 bits 8 = +/- 256 bits 9 = +/- 512 bits Enumeration: 'size512bits': 9, 'size2048bits': 2, 'size4096bits': 3, 'size256bits': 8, 'size128bits': 7, 'size8192bits': 4, 'disabled': 0, 'size16384bits': 5, 'size32786bits': 6, 'size1024bits': 1.
                   cdm570RxDescrambler 1.3.6.1.4.1.6247.24.1.2.3.10 integer read-write
Rx descrambler state, where: 0 = Off 1 = On (default descrambler type) 2 = On - IESS-315 (Turbo only) Enumeration: 'off': 0, 'onIESS315': 2, 'onDefault': 1.
                   cdm570RxDemodAcqSweepWidth 1.3.6.1.4.1.6247.24.1.2.3.11 integer read-write
Rx +/- acquisition sweep range of demodulator, in KHz, ranging from: +/- 1 to +/- 32 KHz (rates < 625 ksym/second) or +/- 1 to 200 KHz (rates >= 625 ksym/second).
                   cdm570RxSymbolRate 1.3.6.1.4.1.6247.24.1.2.3.12 integer read-only
Rx symbol rate in symbols per second (sps) Units = symbols per second (sps) Resolution = 1 sps
               cdm570Frame 1.3.6.1.4.1.6247.24.1.2.4
                   cdm570FramingMode 1.3.6.1.4.1.6247.24.1.2.4.1 integer read-write
Unit operating mode, where: 0 = Unframed 1 = EDMAC Framing 2 = EDMAC-2 Framing Enumeration: 'framingEDMAC': 1, 'unframed': 0, 'framingEDMAC2': 2.
                   cdm570EDMAC 1.3.6.1.4.1.6247.24.1.2.4.2
                       cdm570EDMACMode 1.3.6.1.4.1.6247.24.1.2.4.2.1 integer read-write
EDMAC mode, where: 0 = EDMAC Idle 1 = EDMAC Master 2 = EDMAC Slave Enumeration: 'slave': 2, 'idle': 0, 'master': 1.
                       cdm570EDMACAddress 1.3.6.1.4.1.6247.24.1.2.4.2.2 integer read-write
For a Master, the EDMA Address is the range of addresses of distant-end units (modems or transceivers) which this unit, as the Master, will forward messages for. Only values which are integer multiples of ten are permitted. (10, 20, 30, 40, etc....) For a Slave, the EDMAC address is the address of the slave and is query only.
                   cdm570AUPC 1.3.6.1.4.1.6247.24.1.2.4.3
                       cdm570AUPCEnable 1.3.6.1.4.1.6247.24.1.2.4.3.1 integer read-write
AUPC mode enable/disable, where: 0 = Disable 1 = Enable Note: To enable AUPC, framing must FIRST be enabled. Enumeration: 'enable': 1, 'disable': 0.
                       cdm570AUPCRemoteDemodTargetEbNo 1.3.6.1.4.1.6247.24.1.2.4.3.2 integer read-write
Target Eb/No value for remote demod, from 0.0 to 14.9 dB. Units = 0.1 dB.
                       cdm570AUPCTxPowerMaxIncrease 1.3.6.1.4.1.6247.24.1.2.4.3.3 integer read-write
Max increase in Tx Power permitted, from 0 to 9 dB. Units = dB.
                       cdm570AUPCActionOnMaxPower 1.3.6.1.4.1.6247.24.1.2.4.3.4 integer read-write
Defines action on max. power condition, where: 0 = No action 1 = Generate Tx alarm Enumeration: 'generateTxAlarm': 1, 'noAction': 0.
                       cdm570AUPCActionOnRemoteDemodUnlock 1.3.6.1.4.1.6247.24.1.2.4.3.5 integer read-write
Defines action on remote demod unlock, where: 0 = Go to nominal power 1 = Go to max power Enumeration: 'goToMaxPower': 1, 'goToNominalPower': 0.
               cdm570Interface 1.3.6.1.4.1.6247.24.1.2.5
                   cdm570DataInterface 1.3.6.1.4.1.6247.24.1.2.5.1 integer read-write
Terrestrial interface type, where: 0 = EIA-422/EIA-530 DCE 1 = V.35 DCE 2 = EIA-232 (sync) 3 = G.703 T1 AMI (forces Rx and Tx data rates to 1544 kbps) 4 = G.703 T1 B8ZS (forces Rx and Tx data rates to 1544 kbps) 5 = G.703 E1 Unbal AMI (forces Rx and Tx data rates to 2048 kbps) 6 = G.703 E1 Unbal HDB3 (forces Rx and Tx data rates to 2048 kbps) 7 = G.703 E1 Bal AMI (forces Rx and Tx data rates to 2048 kbps) 8 = G.703 E1 Bal HDB3 (forces Rx and Tx data rates to 2048 kbps) 9 = IP (Ethernet) Enumeration: 'interfaceG703E1BalHDB3': 8, 'interfaceG703T1AMI': 3, 'interfaceV35': 1, 'interfaceG703E1UnbalHDB3': 6, 'interfaceEIA232': 2, 'interfaceIP': 9, 'interfaceEIA422': 0, 'interfaceG703E1UnbalAMI': 5, 'interfaceG703T1B8ZS': 4, 'interfaceG703E1BalAMI': 7.
                   cdm570RTSCTSOper 1.3.6.1.4.1.6247.24.1.2.5.2
                       cdm570RTS 1.3.6.1.4.1.6247.24.1.2.5.2.1 integer read-write
Defines how RTS/CTS will operate at the main data interface, where: 0 = RTS/CTS Loop, No Action (RTS and CTS are looped, so that CTS echoes the state of RTS, but RTS does not control the ON/OFF state of the carrier) 1 = Loop, RTS controls Tx Ouput (RTS and CTS are looped, so that CTS echoes the state of RTS and RTS controls the ON/OFF state of the carrier - the modem will not bring up its TX carrier until RTS is asserted.) 2 = Ignore RTS, Assert CTS Query Only: 3 = 1:N system in use, RTS/CTS ignored Enumeration: 'loopRTSCTSNoAction': 0, 'loopRTSControlsTx': 1, 'ignoreRTSAssertCTS': 2, 'ignoreRTSCTS': 3.
                   cdm570G703T1 1.3.6.1.4.1.6247.24.1.2.5.3
                       cdm570T1LineBuildOut 1.3.6.1.4.1.6247.24.1.2.5.3.1 integer read-write
Valid only for T1 interface, where: 0 = 0 - 133 feet 1 = 133 - 266 feet 2 = 266 - 399 feet 3 = 399 - 533 feet 4 = 533 - 655 feet Enumeration: 'distance399To533feet': 3, 'distance0To133feet': 0, 'distance133To266feet': 1, 'distance533To655feet': 4, 'distance266To399feet': 2.
               cdm570Reference 1.3.6.1.4.1.6247.24.1.2.6
                   cdm570ReferenceFrequency 1.3.6.1.4.1.6247.24.1.2.6.1 integer read-write
External reference frequency, where: 0 = Internal 10 MHz 1 = External 1 MHz 2 = External 2 MHz 3 = External 5 MHz 4 = External 10 MHz 5 = External 20 MHz Enumeration: 'ext5MHz': 3, 'ext1MHz': 1, 'ext20MHz': 5, 'ext2MHz': 2, 'ext10MHz': 4, 'int10MHz': 0.
               cdm570AlarmMask 1.3.6.1.4.1.6247.24.1.2.7
                   cdm570AlarmMaskTxFIFO 1.3.6.1.4.1.6247.24.1.2.7.1 integer read-write
Tx FIFO alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
                   cdm570AlarmMaskG703BPV 1.3.6.1.4.1.6247.24.1.2.7.2 integer read-write
G.703 BPV alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
                   cdm570AlarmMaskTxAIS 1.3.6.1.4.1.6247.24.1.2.7.3 integer read-write
Tx-AIS alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
                   cdm570AlarmMaskRxAGC 1.3.6.1.4.1.6247.24.1.2.7.4 integer read-write
Rx AGC alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
                   cdm570AlarmMaskEbNoAlarm 1.3.6.1.4.1.6247.24.1.2.7.5 integer read-write
Eb/No alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
                   cdm570AlarmMaskRxAIS 1.3.6.1.4.1.6247.24.1.2.7.6 integer read-write
Rx-AIS alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
                   cdm570AlarmMaskBufferSlip 1.3.6.1.4.1.6247.24.1.2.7.7 integer read-write
Buffer slip alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
                   cdm570AlarmMaskExtReference 1.3.6.1.4.1.6247.24.1.2.7.8 integer read-write
External reference alarm mask, where: 0 = Unmasked 1 = Masked Enumeration: 'unmasked': 0, 'masked': 1.
               cdm570ODU 1.3.6.1.4.1.6247.24.1.2.8
           cdm570Monitor 1.3.6.1.4.1.6247.24.1.3
               cdm570Alarms 1.3.6.1.4.1.6247.24.1.3.1
                   cdm570UnitAlarms 1.3.6.1.4.1.6247.24.1.3.1.1 integer read-only
Modem Unit Faults: Value Description of unit fault 0 No faults 1 +5 Volt power supply 2 +12 Volt power supply 3 -5 Volt power supply 4 +23 Volt power supply 5 -12 Volt power supply 6 Tx synthesizer lock 7 Rx 1st LO synthesize lock 8 Rx 2nd LO synthesize lock 9 Ref PLL lock 14 MPP50 (IP Module) Fault 15 EEPROM checksum error Enumeration: 'rx1stLOSynthesizerLock': 7, 'rx2ndLOSynthesizerLock': 8, 'powerSupply5volts': 1, 'powerSupplyNeg12volts': 5, 'txSynthesizerLock': 6, 'noFaults': 0, 'powerSupply12volts': 2, 'mpp50Fault': 14, 'refPLLLock': 9, 'powerSupply23volts': 4, 'checksumErrorEEPROM': 15, 'powerSupplyNeg5volts': 3.
                   cdm570TxAlarms 1.3.6.1.4.1.6247.24.1.3.1.2 integer read-only
Modem TX Traffic Faults: Value Description of Tx Traffic status 0 Tx traffic OK 1 No clock from terrestrial interface 3 Tx FIFO slip 5 Loss of External Reference 7 AUPC upper limit reached 9 AIS Detected on incoming data 11 Bipolar violation on G.705 interface Enumeration: 'aupcUpperLimitReached': 7, 'noClockFromTerrestrialInterface': 1, 'aisDetectedOnIncomingData': 9, 'bipolarViolationOnG703Interface': 11, 'txFIFOSlip': 3, 'lostExternalReference': 5, 'txTrafficOK': 0.
                   cdm570RxAlarms 1.3.6.1.4.1.6247.24.1.3.1.3 integer read-only
Modem RX Traffic Faults Value Description of status parameter 0 Rx Traffic OK 1 Demodulator unlocked 3 AGC Alarm - signal out of range 5 RS Frame sync alarm 7 EDMAC Frame sync alarm 10 Buffer underflow 11 Buffer overflow 13 Eb/No alarm 15 AIS detected on incoming data Enumeration: 'demodulatorUnlocked': 1, 'ebNoAlarm': 13, 'rxTrafficOK': 0, 'aisDetectedOnIncomingData': 15, 'agcAlarmSignalOutOfRange': 3, 'bufferOverflow': 11, 'edmacFrameSyncAlarm': 7, 'bufferUnderflow': 10, 'rsFrameSyncAlarm': 5.
               cdm570RxParams 1.3.6.1.4.1.6247.24.1.3.2
                   cdm570RxBERMultiplier 1.3.6.1.4.1.6247.24.1.3.2.1 integer read-only
Estimated corrected BER. The BER is calculated by mubliplying the Multiplier by 10E-10. Calculuation: RxBER = (Multiplier) * 0.0000000001 Returns 2147483647 (max int) if demod is unlocked.
                   cdm570BufferFillState 1.3.6.1.4.1.6247.24.1.3.2.2 integer read-only
Unit returns the value of the buffer fill state, between 1 to 99%. Returns 0 if demodulator is unlocked. Returns -1 if buffer is disabled.
                   cdm570RxFrequencyOffset 1.3.6.1.4.1.6247.24.1.3.2.3 integer read-only
Unit returns the value of the measured frequency offset of the carrier being demodulated in Hz. Units = Hz. Resolution 100 Hz. Range = -200,000 Hz to 0 Hz and 0 Hz to 200,000 Hz.
                   cdm570RxSignalLevel 1.3.6.1.4.1.6247.24.1.3.2.4 integer read-only
Unit returns the value of the Rx signal level, in dBm, between -99 dBm and -5 dBm. Returns -100 if signal is less than -99 dBm. Returns -4 if signal is greater than -5 dBm.
                   cdm570RxEbNo 1.3.6.1.4.1.6247.24.1.3.2.5 integer read-only
Unit returns the value of Eb/No, between 0 and 16 db. Units = 0.1 dB. Resolution 0.1 dB. Returns 999 if demod is unlocked. For values greater than 16 dB, the reply will be 160.
               cdm570EventLog 1.3.6.1.4.1.6247.24.1.3.3
                   cdm570StoredEventsTable 1.3.6.1.4.1.6247.24.1.3.3.1 no-access
The table for stored events.
                       cdm570StoredEventsEntry 1.3.6.1.4.1.6247.24.1.3.3.1.1 no-access
The entry for the stored events table.
                           cdm570EventIndex 1.3.6.1.4.1.6247.24.1.3.3.1.1.1 integer read-only
The index for stored events table.
                           cdm570EventDate 1.3.6.1.4.1.6247.24.1.3.3.1.1.2 displaystring read-only
The date of the event in the form ddmmyy, where dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99)
                           cdm570EventTime 1.3.6.1.4.1.6247.24.1.3.3.1.1.3 displaystring read-only
The time of the event in the form hhmmss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59)
                           cdm570EventDescription 1.3.6.1.4.1.6247.24.1.3.3.1.1.4 displaystring read-only
The event description string with following format: {1 of the following: Clear, Fault, Info} - {Texual Description of Event}
                   cdm570ClearAllStoredEvents 1.3.6.1.4.1.6247.24.1.3.3.2 integer read-write
Forces the software to clear the event log. This is a command only. Enumeration: 'clearAll': 1.
               cdm570Statistics 1.3.6.1.4.1.6247.24.1.3.4
                   cdm570StatisticsSampleInterval 1.3.6.1.4.1.6247.24.1.3.4.1 integer read-write
Used to set the sample interval for the statistics logging function, where the enumerated lists goes from 0 to 9 in 10 minute steps. Setting 0 disables the statistics logging function. Enumeration: 'mins70': 7, 'mins40': 4, 'mins50': 5, 'disabled': 0, 'mins10': 1, 'mins60': 6, 'mins80': 8, 'mins90': 9, 'mins20': 2, 'mins30': 3.
                   cdm570StoredStatisticsTable 1.3.6.1.4.1.6247.24.1.3.4.2 no-access
Description.
                       cdm570StoredStatisticsEntry 1.3.6.1.4.1.6247.24.1.3.4.2.1 no-access
Entry for stored statistics table.
                           cdm570StatisticIndex 1.3.6.1.4.1.6247.24.1.3.4.2.1.1 integer read-only
Index for stored statistics table.
                           cdm570StatisticDate 1.3.6.1.4.1.6247.24.1.3.4.2.1.2 displaystring read-only
The date of the statistic in the form ddmmyy, where: dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99)
                           cdm570StatisticTime 1.3.6.1.4.1.6247.24.1.3.4.2.1.3 displaystring read-only
The time of the statistic in the form hhmmss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59)
                           cdm570StatisticMinEbNo 1.3.6.1.4.1.6247.24.1.3.4.2.1.4 integer read-only
Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period.
                           cdm570StatisticAvgEbNo 1.3.6.1.4.1.6247.24.1.3.4.2.1.5 integer read-only
Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period.
                           cdm570StatisticMaxTxPowerIncrease 1.3.6.1.4.1.6247.24.1.3.4.2.1.6 integer read-only
Max. Tx power level increase during sample period. Units = 0.1 dB
                           cdm570StatisticAvgTxPowerIncrease 1.3.6.1.4.1.6247.24.1.3.4.2.1.7 integer read-only
Average Tx power level increase during sample period. Units = 0.1 dB
                   cdm570ClearAllStoredStatistics 1.3.6.1.4.1.6247.24.1.3.4.3 integer read-write
Forces the software to clear the statistics log. This is a command only. Enumeration: 'clearAll': 1.
               cdm570AUPCParams 1.3.6.1.4.1.6247.24.1.3.5
                   cdm570AUPCRemoteDemodEbNo 1.3.6.1.4.1.6247.24.1.3.5.1 integer read-only
Returns the value of the Eb/No ofthe remote demodulator. Units = 0.1 dB Responds 999 = remote demod unlocked. Responds 0 = EDMAC is disabled.
                   cdm570AUPCTxPowerIncrease 1.3.6.1.4.1.6247.24.1.3.5.2 integer read-only
Returns the increase in Tx power level, in 0.1 dB (from the nominal setting) due to the action of AUPC. Responds with 999 if AUPC is disabled.
               cdm570ODUParams 1.3.6.1.4.1.6247.24.1.3.6
           cdm570Test 1.3.6.1.4.1.6247.24.1.4
               cdm570UnitTestMode 1.3.6.1.4.1.6247.24.1.4.1 integer read-write
Unit Test Mode where: 0 = Normal Mode 1 = IF Loopback 2 = Digital Loopback 3 = IO Loopback 4 = RF Loopback 5 = Tx CW 6 = Tx Alternating Pattern Enumeration: 'normalMode': 0, 'digitalLoopBack': 2, 'ioLoopBack': 3, 'ifLoopBack': 1, 'rfLoopback': 4, 'txCW': 5, 'txAlternatingPattern': 6.
           cdm570SaveLoad 1.3.6.1.4.1.6247.24.1.5
               cdm570ConfigurationSave 1.3.6.1.4.1.6247.24.1.5.1 integer read-write
Causes the device to store the current modem configuration in configuration memory location defined by the argument (0 to 9). This is a COMMAND ONLY. Get always responds with 0.
               cdm570ConfigurationLoad 1.3.6.1.4.1.6247.24.1.5.2 integer read-write
Causes the device to retrieve a previously stored modem configuration from configuration memory location defined by the argument (0 to 9). This is a COMMAND ONLY. Get always responds with 0.
           cdm570Util 1.3.6.1.4.1.6247.24.1.6
               cdm570Buffer 1.3.6.1.4.1.6247.24.1.6.1
                   cdm570ReCenterBuffer 1.3.6.1.4.1.6247.24.1.6.1.1 integer read-write
Forces the software to recenter the receive Plesiochronous/Doppler buffer. This is a command only. Enumeration: 'reCenter': 1.
               cdm570RealTimeClock 1.3.6.1.4.1.6247.24.1.6.2
                   cdm570RTCDate 1.3.6.1.4.1.6247.24.1.6.2.1 displaystring read-write
A date in the form dd/mm/yy, where dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99)
                   cdm570RTCTime 1.3.6.1.4.1.6247.24.1.6.2.2 displaystring read-write
A time in the form hh:mm:ss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59)
               cdm570InternalReference 1.3.6.1.4.1.6247.24.1.6.3
                   cdm570WarmUpDelay 1.3.6.1.4.1.6247.24.1.6.3.2 integer read-write
Warm-up delay for internal frequency reference (OCXO), where: 0 = Disabled (instant on - no delay for OCXO to reach temperature) 1 = Enabled (unit waits until OCXO reaches correct temperature) Enumeration: 'enable': 1, 'disable': 0.
                   cdm570WarmUpCountdown 1.3.6.1.4.1.6247.24.1.6.3.3 integer read-write
As a query, returns the Warm-up delay countdown in seconds remaining. As a command, only takes the argument 0 and is used to truncate the warm-up delay period to zero, forcing the unit into 'instanct-on' mode.
               cdm570ID 1.3.6.1.4.1.6247.24.1.6.4
                   cdm570CircuitID 1.3.6.1.4.1.6247.24.1.6.4.1 displaystring read-write
Sets or queries the user-defined Circuit ID string, which is a fixed length of 24 characters. Valid characters include: Space ( ) * + - , . / 0 thru 9 and A thru Z
               cdm570Redundancy 1.3.6.1.4.1.6247.24.1.6.5
                   cdm570RedundancyState 1.3.6.1.4.1.6247.24.1.6.5.1 integer read-only
Unit returns the redundancy state of the unit, where: 0 = Offline 1 = Online Enumeration: 'offline': 0, 'online': 1.
                   cdm570ForceRedundentSwitch 1.3.6.1.4.1.6247.24.1.6.5.2 integer read-write
Force redundundent switch command. Enumeration: 'forceSwitch': 1.
               cdm570ODUComms 1.3.6.1.4.1.6247.24.1.6.6
                   cdm570ODUCommsEnabled 1.3.6.1.4.1.6247.24.1.6.6.1 integer read-write
ODU Comms, where 0 = Disabled 1 = Enabled Enumeration: 'disabled': 0, 'enabled': 1.
       cdm570Notifications 1.3.6.1.4.1.6247.24.2
           cdm570NotificationsPrefix 1.3.6.1.4.1.6247.24.2.0
               cdm570UnitAlarm 1.3.6.1.4.1.6247.24.2.0.1
Modem Unit Faults Trap
               cdm570TxTrafficAlarm 1.3.6.1.4.1.6247.24.2.0.2
Modem TX Traffic Faults Trap
               cdm570RxTrafficAlarm 1.3.6.1.4.1.6247.24.2.0.3
Modem RX Traffic Faults Trap
       cdm570Conformance 1.3.6.1.4.1.6247.24.3
           cdm570Groups 1.3.6.1.4.1.6247.24.3.1
               cdm570ObjectsGroup 1.3.6.1.4.1.6247.24.3.1.1
CDM-570 (Both L-Band and IF-Band) Objects Group.
               cdm570NotificationsGroup 1.3.6.1.4.1.6247.24.3.1.2
CDM-570 (Both L-Band and IF-Band) Notifications Group.
           cdm570Compliances 1.3.6.1.4.1.6247.24.3.2
               cdm570Compliance 1.3.6.1.4.1.6247.24.3.2.1
CDM-570 (Both L-Band and IF-Band) Compliance.