BIANCA-X4000-MIBSYS-MIB: View SNMP OID List / Download MIB

VENDOR: BINTEC COMMUNICATIONS GMBH


 Home MIB: BIANCA-X4000-MIBSYS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 org 1.3
     dod 1.3.6
         internet 1.3.6.1
             private 1.3.6.1.4
                 enterprises 1.3.6.1.4.1
                     bintec 1.3.6.1.4.1.272
                             bibo 1.3.6.1.4.1.272.4
                                 sys 1.3.6.1.4.1.272.4.17
                                       x4 1.3.6.1.4.1.272.4.17.2
                                           sysX4Config 1.3.6.1.4.1.272.4.17.2.1
                                               sysX4ConfigLcdBrightness 1.3.6.1.4.1.272.4.17.2.1.1 integer read-write
This variable allows to control the brightness of the LCD display. Lower values mean less, higher values mean more brightness. Zero means no brightness.
                                               sysX4ConfigLcdContrast 1.3.6.1.4.1.272.4.17.2.1.2 integer read-write
This variable allows to control the contrast of the LCD display. Lower values mean less, higher values mean more contrast. Zero means factory settings.
                                               sysX4ConfigLcdConfigure 1.3.6.1.4.1.272.4.17.2.1.3 integer read-write
This variable determines whether it is possible to configure the brick by using the LCD display and the buttons. Enumeration: 'on': 2, 'off': 1.
                                               sysX4ConfigLcdPin 1.3.6.1.4.1.272.4.17.2.1.4 displaystring read-write
The PIN is the personal identification number that is needed for authorisation for display configurations. It consists solely of digits and must be 4 characters long. Default Value is '0000'.
                                               sysX4ConfigLcdIdleTimer 1.3.6.1.4.1.272.4.17.2.1.5 integer read-write
After this time the display screen changes to default screen. Default Value is 5. If this value is set to 0, change to defaultscreen is disabled
                                               sysX4ConfigLcdDefaultScreen 1.3.6.1.4.1.272.4.17.2.1.6 displaystring read-write
This screen will be displayed after the LcdIdleTimer has elapsed. Default Value is MainMenu.
                                               sysX4ConfigLcdLanguage 1.3.6.1.4.1.272.4.17.2.1.7 displaystring read-write
Choose your display language.
                                               sysX4ConfigTempUnit 1.3.6.1.4.1.272.4.17.2.1.8 integer read-only
This variable defines the unit of sysX4Config*Temp, either Celsius or Fahrenheit. Enumeration: 'fahrenheit': 2, 'celsius': 1.
                                               sysX4ConfigMainTemp 1.3.6.1.4.1.272.4.17.2.1.9 integer read-only
This variable shows the actual main board temperature measured in the units Fahrenheit or Celsius.
                                               sysX4ConfigMainTempAlarmThreshold 1.3.6.1.4.1.272.4.17.2.1.10 integer read-write
system mainboard temperature threshold.
                                               sysX4ConfigMainTempAlarmTrap 1.3.6.1.4.1.272.4.17.2.1.11 integer read-only
If the system temperature raises above the threshold, a alarm trap is generated every 60 seconds. Enumeration: 'critical': 2, 'normal': 1.
                                               sysX4ConfigMod1Temp 1.3.6.1.4.1.272.4.17.2.1.12 integer read-only
This variable shows the actual module sensor1 temperature in the units Fahrenheit or Celsius.
                                               sysX4ConfigMod1TempAlarmThreshold 1.3.6.1.4.1.272.4.17.2.1.13 integer read-write
actual module sensor1 temperature threshold.
                                               sysX4ConfigMod1TempAlarmTrap 1.3.6.1.4.1.272.4.17.2.1.14 integer read-only
If the actual module sensor1 temperature raises above the threshold, a alarm trap is generated every 60 seconds. Enumeration: 'critical': 2, 'normal': 1.
                                               sysX4ConfigMod2Temp 1.3.6.1.4.1.272.4.17.2.1.15 integer read-only
This variable shows the actual module sensor2 temperature in the units Fahrenheit or Celsius.
                                               sysX4ConfigMod2TempAlarmThreshold 1.3.6.1.4.1.272.4.17.2.1.16 integer read-write
actual module sensor2 temperature threshold.
                                               sysX4ConfigMod2TempAlarmTrap 1.3.6.1.4.1.272.4.17.2.1.17 integer read-only
If the actual module sensor2 temperature raises above the threshold, a alarm trap is generated every 60 seconds. Enumeration: 'critical': 2, 'normal': 1.
                                           sysX4Traps 1.3.6.1.4.1.272.4.17.2.2
                                                 sysX4TrapMainTempCritical 1.3.6.1.4.1.272.4.17.2.20.1
This trap signifies that the system board temperature raises above the critical alarm-threshold
                                                 sysX4TrapMainTempOk 1.3.6.1.4.1.272.4.17.2.20.2
Normal system board temperature has been restored.
                                                 sysX4TrapMod1TempCritical 1.3.6.1.4.1.272.4.17.2.20.3
This trap signifies that the actual module (sensor 1) temperature raises above the critical alarm-threshold
                                                 sysX4TrapMod1Temp1Ok 1.3.6.1.4.1.272.4.17.2.20.4
Normal temperature of actual module (sensor 1) has been restored.
                                                 sysX4TrapMod2TempCritical 1.3.6.1.4.1.272.4.17.2.20.5
This trap signifies that the actual module (sensor 2) temperature raises above the critical alarm-threshold
                                                 sysX4TrapMod2TempOk 1.3.6.1.4.1.272.4.17.2.20.6
Normal temperature of actual module (sensor 2) has been restored.