ASCEND-MIBLESNET-MIB: View SNMP OID List / Download MIB

VENDOR: ASCEND COMMUNICATIONS INC.


 Home MIB: ASCEND-MIBLESNET-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 miblesNetworkProfile 1.3.6.1.4.1.529.23.178
         miblesNetworkProfileTable 1.3.6.1.4.1.529.23.178.1 no-access
A list of miblesNetworkProfile profile entries.
             miblesNetworkProfileEntry 1.3.6.1.4.1.529.23.178.1.1 no-access
A miblesNetworkProfile entry containing objects that maps to the parameters of miblesNetworkProfile profile.
                 lesNetworkProfile_Shelf_o 1.3.6.1.4.1.529.23.178.1.1.1 integer read-only
                 lesNetworkProfile_Slot_o 1.3.6.1.4.1.529.23.178.1.1.2 integer read-only
                 lesNetworkProfile_Item_o 1.3.6.1.4.1.529.23.178.1.1.3 integer read-only
                 lesNetworkProfile_Name 1.3.6.1.4.1.529.23.178.1.1.4 displaystring read-write
For future use. The current design does not use the name field but instead references lines by the physical address; we may in the future support referencing lines by name as well as by address. The name consists of a null terminated ascii string supplied by the user; it defaults to the ascii form of the line physical address.
                 lesNetworkProfile_PhysicalAddress_Shelf 1.3.6.1.4.1.529.23.178.1.1.5 integer read-write
The number of the shelf that the addressed physical device resides on. Enumeration: 'anyShelf': 1, 'shelf2': 3, 'shelf3': 4, 'shelf1': 2, 'shelf6': 7, 'shelf7': 8, 'shelf4': 5, 'shelf5': 6, 'shelf8': 9, 'shelf9': 10.
                 lesNetworkProfile_PhysicalAddress_Slot 1.3.6.1.4.1.529.23.178.1.1.6 integer read-write
The number of the slot that the addressed physical device resides on. Enumeration: 'aLim': 55, 'bLim': 56, 'trunkModule2': 46, 'slot36': 37, 'firstControlModule': 53, 'trunkModule1': 45, 'rightController': 50, 'slot28': 29, 'slot29': 30, 'slot24': 25, 'slot25': 26, 'slot26': 27, 'slot27': 28, 'slot20': 21, 'slot21': 22, 'slot22': 23, 'slot23': 24, 'slotPrimary': 59, 'cLim': 57, 'slot40': 41, 'secondControlModule': 54, 'leftController': 49, 'slot39': 40, 'controlModule': 51, 'slot9': 10, 'slot8': 9, 'controller': 42, 'slot38': 39, 'slot1': 2, 'slot3': 4, 'slot2': 3, 'slot5': 6, 'slot4': 5, 'slot7': 8, 'slot6': 7, 'slot11': 12, 'slot10': 11, 'slot13': 14, 'slot12': 13, 'slot15': 16, 'slot14': 15, 'slot17': 18, 'slot16': 17, 'slot19': 20, 'slot18': 19, 'slot31': 32, 'slot30': 31, 'slot37': 38, 'anySlot': 1, 'slot35': 36, 'slot34': 35, 'slot33': 34, 'dLim': 58, 'slot32': 33.
                 lesNetworkProfile_PhysicalAddress_ItemNumber 1.3.6.1.4.1.529.23.178.1.1.7 integer read-write
A number that specifies an addressable entity within the context of shelf and slot.
                 lesNetworkProfile_Enabled 1.3.6.1.4.1.529.23.178.1.1.8 integer read-write
TRUE if Loop Emulation Services are enabled, otherwise FALSE. Enumeration: 'yes': 2, 'no': 1.
                 lesNetworkProfile_NailedGroup 1.3.6.1.4.1.529.23.178.1.1.9 integer read-write
A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group.
                 lesNetworkProfile_Action_o 1.3.6.1.4.1.529.23.178.1.1.10 integer read-write
Enumeration: 'deleteProfile': 3, 'createProfile': 2, 'noAction': 1.
         miblesNetworkProfile_PotsLineConfigTable 1.3.6.1.4.1.529.23.178.2 no-access
A list of miblesNetworkProfile__pots_line_config profile entries.
             miblesNetworkProfile_PotsLineConfigEntry 1.3.6.1.4.1.529.23.178.2.1 no-access
A miblesNetworkProfile__pots_line_config entry containing objects that maps to the parameters of miblesNetworkProfile__pots_line_config profile.
                 lesNetworkProfile_PotsLineConfig_Shelf_o 1.3.6.1.4.1.529.23.178.2.1.1 integer read-only
                 lesNetworkProfile_PotsLineConfig_Slot_o 1.3.6.1.4.1.529.23.178.2.1.2 integer read-only
                 lesNetworkProfile_PotsLineConfig_Item_o 1.3.6.1.4.1.529.23.178.2.1.3 integer read-only
                 lesNetworkProfile_PotsLineConfig_Index_o 1.3.6.1.4.1.529.23.178.2.1.4 integer read-only
                 lesNetworkProfile_PotsLineConfig_Enabled 1.3.6.1.4.1.529.23.178.2.1.5 integer read-write
TRUE if this loop is enabled, otherwise FALSE. Enumeration: 'yes': 2, 'no': 1.
                 lesNetworkProfile_PotsLineConfig_Mode 1.3.6.1.4.1.529.23.178.2.1.6 integer read-write
POT's loop mode. Enumeration: 'groundStart': 1, 'loopStart': 2.
                 lesNetworkProfile_PotsLineConfig_EncodingFormatProfile 1.3.6.1.4.1.529.23.178.2.1.7 integer read-write
ITU-T standardized Encoding Format Profiles. From Annex B through H of I.366.2.
                 lesNetworkProfile_PotsLineConfig_FwdDisc 1.3.6.1.4.1.529.23.178.2.1.8 integer read-write
TRUE if Forward Disconnect feature is enabled, otherwise FALSE. Enumeration: 'yes': 2, 'no': 1.
                 lesNetworkProfile_PotsLineConfig_OverRideCid 1.3.6.1.4.1.529.23.178.2.1.9 integer read-write
Override default allocation of CID's when ELCP is not used.