Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 mibimaGroupConfig 1.3.6.1.4.1.529.23.23
       mibimaGroupConfigTable 1.3.6.1.4.1.529.23.23.1 no-access
A list of mibimaGroupConfig profile entries.
           mibimaGroupConfigEntry 1.3.6.1.4.1.529.23.23.1.1 no-access
A mibimaGroupConfig entry containing objects that maps to the parameters of mibimaGroupConfig profile.
               imaGroupConfig_Name 1.3.6.1.4.1.529.23.23.1.1.1 displaystring read-only
Name of IMA Group Config profile.
               imaGroupConfig_Active 1.3.6.1.4.1.529.23.23.1.1.2 integer read-write
TRUE if the line is enabled, otherwise FALSE. Enumeration: 'yes': 2, 'no': 1.
               imaGroupConfig_NailedGroup 1.3.6.1.4.1.529.23.23.1.1.3 integer read-write
The nailed group to which this IMA group belongs to
               imaGroupConfig_GroupSymmetryMode 1.3.6.1.4.1.529.23.23.1.1.4 integer read-write
Symmetry mode of group to which this link belongs to Enumeration: 'symmetricOperation': 2, 'configurationAsymmetric': 4, 'asymmetricOperation': 3.
               imaGroupConfig_Version 1.3.6.1.4.1.529.23.23.1.1.5 integer read-write
IMA spec version Enumeration: 'v10': 2, 'v11': 4.
               imaGroupConfig_DoVersionFallback 1.3.6.1.4.1.529.23.23.1.1.6 integer read-write
Automatically fall back to v 1.0 if FE is detected to be v 1.0, otherwise move to configAborted state Enumeration: 'yes': 2, 'no': 1.
               imaGroupConfig_Lasr 1.3.6.1.4.1.529.23.23.1.1.7 integer read-write
enable/disable LASR (Link addition and slow recovery) procedures Enumeration: 'yes': 2, 'no': 1.
               imaGroupConfig_NeTxClkMode 1.3.6.1.4.1.529.23.23.1.1.8 integer read-write
Group Clocking mode Enumeration: 'itc': 3, 'ctc': 2.
               imaGroupConfig_TxMinNumLinks 1.3.6.1.4.1.529.23.23.1.1.9 integer read-write
Minimum Number of Tx Links to be active for group to remain in operational state
               imaGroupConfig_RxMinNumLinks 1.3.6.1.4.1.529.23.23.1.1.10 integer read-write
Minimum Number of Rx Links to be active for group to remain in operational state
               imaGroupConfig_ImaId 1.3.6.1.4.1.529.23.23.1.1.11 integer read-write
IMA ID of the group
               imaGroupConfig_FrameLength 1.3.6.1.4.1.529.23.23.1.1.12 integer read-write
Frame length for the group (M) Enumeration: 'n-64': 65, 'n-256': 257, 'n-32': 33, 'n-128': 129.
               imaGroupConfig_DiffDelayMax 1.3.6.1.4.1.529.23.23.1.1.13 integer read-write
Maximum differential delay of group in msec
               imaGroupConfig_CheckFarEndImaId 1.3.6.1.4.1.529.23.23.1.1.14 integer read-write
check/compare the expected-far-end-ima-id with the far-end IMA ID during group start up Enumeration: 'yes': 2, 'no': 1.
               imaGroupConfig_ExpectedFarEndImaId 1.3.6.1.4.1.529.23.23.1.1.15 integer read-write
if check-far-end-ima-id set to yes, then the far-end IMA ID is compared against this number during group startup, GSM moves to ConfigAborted if it does not match
               imaGroupConfig_FarEndCheckFrameLength 1.3.6.1.4.1.529.23.23.1.1.16 integer read-write
check/compare the Expected frame length with the far-end frame length during group start up Enumeration: 'yes': 2, 'no': 1.
               imaGroupConfig_ExpectedFarEndFrameLength 1.3.6.1.4.1.529.23.23.1.1.17 integer read-write
If far-end-check-frame-length is set to yes, then the far-end frame length is compared against this number during group startup, GSM moves to ConfigAborted, if it does not match. Enumeration: 'n-64': 65, 'n-256': 257, 'n-32': 33, 'n-128': 129.
               imaGroupConfig_AtmIfDelay 1.3.6.1.4.1.529.23.23.1.1.18 integer read-write
minimum time (in seconds) between the subsequent ATM layer (ie IDCR changes) indications
               imaGroupConfig_TppTestLink 1.3.6.1.4.1.529.23.23.1.1.19 integer read-write
Designate a link index as the test link for use in the Test Pattern Procedure.
               imaGroupConfig_TppTestPattern 1.3.6.1.4.1.529.23.23.1.1.20 integer read-write
The test pattern transmitted in the ICP cell (octet 17) on the link during the IMA Test Pattern Procedure.
               imaGroupConfig_TppState 1.3.6.1.4.1.529.23.23.1.1.21 integer read-write
Enable or disable the Test Pattern Procedure. Enumeration: 'disabled': 2, 'operating': 3.
               imaGroupConfig_VpSwitchingVpi 1.3.6.1.4.1.529.23.23.1.1.22 integer read-write
The Vpi to be used for the VP switching. Rest of the valid VPIs in valid vpi-vci-range will be used for the VC switching. Changes in this range will take effect immediately. THE USER SHOULD BE VERY CAREFUL WHILE CHANGING THIS VALUE BECAUSE ALL CONNECTIONS ON THE LIM WHERE THIS PORT BELONGS WILL BE DROPPED IN ORDER TO MAKE THIS NEW VALUE EFFECTIVE IMMEDIATELY.
               imaGroupConfig_Action_o 1.3.6.1.4.1.529.23.23.1.1.23 integer read-write
Enumeration: 'deleteProfile': 3, 'createProfile': 2, 'noAction': 1.
               imaGroupConfig_IgnoreLineup 1.3.6.1.4.1.529.23.23.1.1.24 integer read-write
Ignore line up value for this IMA Group. Enumeration: 'yes': 3, 'no': 2, 'systemDefined': 1.