Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 mibdBAProfile 1.3.6.1.4.1.529.23.71
       mibdBAProfileTable 1.3.6.1.4.1.529.23.71.1 no-access
A list of mibdBAProfile profile entries.
           mibdBAProfileEntry 1.3.6.1.4.1.529.23.71.1.1 no-access
A mibdBAProfile entry containing objects that maps to the parameters of mibdBAProfile profile.
               dBAProfile_Shelf_o 1.3.6.1.4.1.529.23.71.1.1.1 integer read-only
               dBAProfile_Slot_o 1.3.6.1.4.1.529.23.71.1.1.2 integer read-only
               dBAProfile_Item_o 1.3.6.1.4.1.529.23.71.1.1.3 integer read-only
               dBAProfile_LogicalItem_o 1.3.6.1.4.1.529.23.71.1.1.4 integer read-only
               dBAProfile_LogicalAddress_PhysicalAddress_Shelf 1.3.6.1.4.1.529.23.71.1.1.5 integer read-write
The number of the shelf that the addressed physical device resides on. Enumeration: 'anyShelf': 1, 'shelf2': 3, 'shelf3': 4, 'shelf1': 2, 'shelf6': 7, 'shelf7': 8, 'shelf4': 5, 'shelf5': 6, 'shelf8': 9, 'shelf9': 10.
               dBAProfile_LogicalAddress_PhysicalAddress_Slot 1.3.6.1.4.1.529.23.71.1.1.6 integer read-write
The number of the slot that the addressed physical device resides on. Enumeration: 'aLim': 55, 'bLim': 56, 'trunkModule2': 46, 'slot36': 37, 'firstControlModule': 53, 'trunkModule1': 45, 'rightController': 50, 'slot28': 29, 'slot29': 30, 'slot24': 25, 'slot25': 26, 'slot26': 27, 'slot27': 28, 'slot20': 21, 'slot21': 22, 'slot22': 23, 'slot23': 24, 'slotPrimary': 59, 'cLim': 57, 'slot40': 41, 'secondControlModule': 54, 'leftController': 49, 'slot39': 40, 'controlModule': 51, 'slot9': 10, 'slot8': 9, 'controller': 42, 'slot38': 39, 'slot1': 2, 'slot3': 4, 'slot2': 3, 'slot5': 6, 'slot4': 5, 'slot7': 8, 'slot6': 7, 'slot11': 12, 'slot10': 11, 'slot13': 14, 'slot12': 13, 'slot15': 16, 'slot14': 15, 'slot17': 18, 'slot16': 17, 'slot19': 20, 'slot18': 19, 'slot31': 32, 'slot30': 31, 'slot37': 38, 'anySlot': 1, 'slot35': 36, 'slot34': 35, 'slot33': 34, 'dLim': 58, 'slot32': 33.
               dBAProfile_LogicalAddress_PhysicalAddress_ItemNumber 1.3.6.1.4.1.529.23.71.1.1.7 integer read-write
A number that specifies an addressable entity within the context of shelf and slot.
               dBAProfile_LogicalAddress_LogicalItem 1.3.6.1.4.1.529.23.71.1.1.8 integer read-write
A number that specifies an addressable logical entity within the context of a physical address.
               dBAProfile_Name 1.3.6.1.4.1.529.23.71.1.1.9 displaystring read-write
DBA Profiles are recognized by their names given them by the user. The name is a standard null terminated ASCII string.
               dBAProfile_PhoneNumber 1.3.6.1.4.1.529.23.71.1.1.10 displaystring read-write
The number to dial for this call.
               dBAProfile_BillingNumber 1.3.6.1.4.1.529.23.71.1.1.11 displaystring read-write
The billing number to use which is either a 'calling party number' or a 'billing suffix' that is appended to the end of the phone number.
               dBAProfile_oCallType 1.3.6.1.4.1.529.23.71.1.1.12 integer read-write
session channel type. Enumeration: 'callCh2Ch': 4, 'callChNByBonding': 2, 'callChFt1StaticBo': 8, 'callCh1Ch': 3, 'callChFt1Aim': 6, 'callChFt1Bo': 7, 'callChFt1': 5, 'callChNBy': 1, 'numberOfCallChTypes': 9.
               dBAProfile_oCallMgm 1.3.6.1.4.1.529.23.71.1.1.13 integer read-write
One of the management type listed above. Enumeration: 'callMgmtOneOfEight': 6, 'callMgmtTimeOfDay': 5, 'callMgmtDynamicRate': 3, 'callMgmtDeltaRate': 4, 'numberOfCallMgmtProtocols': 12, 'callMgmtBonding0': 8, 'callMgmtBonding1': 9, 'callMgmtBonding2': 10, 'callMgmtBonding3': 11, 'callMgmtOneOfFourty': 7, 'callMgmtStaticRate': 1, 'callMgmtManualRate': 2.
               dBAProfile_oDataSvc 1.3.6.1.4.1.529.23.71.1.1.14 integer read-write
The type of bearer channel capability to set up for each switched call in the session. Enumeration: 'modem': 43, 'n-1024Clear': 24, 'x30RestrictedBearer': 39, 'n-2456krV110': 51, 'n-64kClear': 3, 'n-14464krV110': 80, 'v32': 66, 'n-1600Clear': 32, 'n-38456krV110': 55, 'n-64kX30Restricted': 41, 'n-1280Clear': 28, 'n-1856Clear': 36, 'n-28864krV110': 81, 'n-19264kV110': 59, 'n-896Clear': 22, 'n-192kClear': 11, 'n-9656krV110': 53, 'n-512Clear': 16, 'n-144kClear': 255, 'n-576Clear': 17, 'n-448Clear': 15, 'n-960Clear': 23, 'n-2464kV110': 56, 'n-4856kV110': 47, 'n-4856krV110': 52, 'n-14456kV110': 74, 'frameRelaySvc': 71, 'n-9664krV110': 63, 'iptoip': 263, 'n-19256krV110': 54, 'v110ClearBearer': 40, 'n-56kRestricted': 2, 'n-704Clear': 19, 'n-1088Clear': 25, 'n-1344Clear': 29, 'wormarq': 73, 'n-14464kV110': 78, 'atmodem': 44, 'n-9656kV110': 48, 'vpnTunnel': 72, 'n-28856krV110': 77, 'n-19264krV110': 64, 'n-38464kV110': 60, 'n-1472Clear': 31, 'atmSvc': 70, 'n-9664kV110': 58, 'n-4864krV110': 62, 'n-38456kV110': 50, 'n-14456krV110': 76, 'n-1536kClear': 8, 'n-1216Clear': 27, 'n-28856kV110': 75, 'n-2464krV110': 61, 'n-384kRestricted': 6, 'n-1792Clear': 35, 'n-56kClear': 5, 'n-320kClear': 13, 'n-19256kV110': 49, 'n-768Clear': 20, 'dws384Clear': 14, 'n-2456kV110': 46, 'voice': 1, 'n-1536kRestricted': 9, 'n-64kRestricted': 4, 'n-128kClear': 10, 'n-4864kV110': 57, 'n-384kClear': 7, 'n-1920Clear': 37, 'phs64k': 67, 'n-1728Clear': 34, 'n-1152Clear': 26, 'n-1664Clear': 33, 'n-56kV110Clear': 42, 'n-1408Clear': 30, 'n-256kClear': 12, 'voiceOverIp': 68, 'n-28864kV110': 79, 'n-832Clear': 21, 'n-640Clear': 18, 'modem31khzAudio': 82, 'n-38464krV110': 65, 'x25Svc': 83.
               dBAProfile_Force56 1.3.6.1.4.1.529.23.71.1.1.15 integer read-write
TRUE if the data should be treated as 7-bit data even if the switchedCallType would normally imply 8 bit data. Enumeration: 'yes': 2, 'no': 1.
               dBAProfile_BaseChannelCount 1.3.6.1.4.1.529.23.71.1.1.16 integer read-write
When the session is initially set up, and if it is a fixed session, the number of channels to be used for the call.
               dBAProfile_IncrementChannelCount 1.3.6.1.4.1.529.23.71.1.1.17 integer read-write
Number of channels to increment as a block.
               dBAProfile_DecrementChannelCount 1.3.6.1.4.1.529.23.71.1.1.18 integer read-write
Number of channels to decrement as a block.
               dBAProfile_oFailAction 1.3.6.1.4.1.529.23.71.1.1.19 integer read-write
If unable to establish a dba session based on the parameters specified, then the action to be taken is specified in the failureAction. Enumeration: 'numberOfFailureActions': 4, 'disc': 1, 'reduce': 2, 'retry': 3.
               dBAProfile_BitInversionRequired 1.3.6.1.4.1.529.23.71.1.1.20 integer read-write
TRUE if the data being transferred from the host should be inverted before being sent to the network, and FALSE otherwise. I think this needs to be supported by the device, but I will check before committing. Also, this affects the network interface too, I think. Enumeration: 'yes': 2, 'no': 1.
               dBAProfile_Ft1Caller 1.3.6.1.4.1.529.23.71.1.1.21 integer read-write
BOOLEAN which is true for Fractional T1 calls when this side is the caller, and FALSE otherwise. Enumeration: 'yes': 2, 'no': 1.
               dBAProfile_Ft1Timeout 1.3.6.1.4.1.529.23.71.1.1.22 integer read-write
               dBAProfile_CallByCallID 1.3.6.1.4.1.529.23.71.1.1.23 integer read-write
The ID for the call-by-call signalling for PRI.
               dBAProfile_CalledNumberType 1.3.6.1.4.1.529.23.71.1.1.24 integer read-write
Indication of whether national number, international number, etc. is specified.
               dBAProfile_UnknownPlanUnknown 1.3.6.1.4.1.529.23.71.1.1.25 integer read-write
If TRUE indicates that UNKNOWN number plan is used in conjunction with unknown number instead of default, ISDN. Enumeration: 'yes': 2, 'no': 1.
               dBAProfile_LocalPlanIsdn 1.3.6.1.4.1.529.23.71.1.1.26 integer read-write
If TRUE indicates that ISDN number plan is used in conjunction with local number instead of default, PRIVATE. Enumeration: 'yes': 2, 'no': 1.
               dBAProfile_TransitNumber 1.3.6.1.4.1.529.23.71.1.1.27 displaystring read-write
The string for use in the 'transit network ie' for PRI calling when going through a LEC.
               dBAProfile_oAutoBERT 1.3.6.1.4.1.529.23.71.1.1.28 integer read-write
Should we BERT at session startup and for how long. Enumeration: 'n-15Sec': 2, 'off': 1, 'n-30Sec': 3, 'n-120Sec': 6, 'n-60Sec': 4, 'numberOfBertTestOptions': 7, 'n-90Sec': 5.
               dBAProfile_TimedCall 1.3.6.1.4.1.529.23.71.1.1.29 integer read-write
TRUE if we should pay attention to the following time period parameters. Not used when the call type is dynamic N-by. Enumeration: 'yes': 2, 'no': 1.
               dBAProfile_FlagIdle 1.3.6.1.4.1.529.23.71.1.1.30 integer read-write
TRUE if looking for flag idle, FALSE when looking for mark idle. Enumeration: 'yes': 2, 'no': 1.
               dBAProfile_oDynAlg 1.3.6.1.4.1.529.23.71.1.1.31 integer read-write
The algorithm to use for determining weighted line utilization. Enumeration: 'quadratic': 3, 'constant': 1, 'linear': 2.
               dBAProfile_SecondsOfHistory 1.3.6.1.4.1.529.23.71.1.1.32 integer read-write
Number of seconds to keep history data around for. This number is in the range of 1 through MAX_HISTORY_SECONDS.
               dBAProfile_AddSecondsOfPersistence 1.3.6.1.4.1.529.23.71.1.1.33 integer read-write
Once the upper threshold of utilization is passed, the number of seconds it should stay there is defined here.
               dBAProfile_RemoveSecondsOfPersistence 1.3.6.1.4.1.529.23.71.1.1.34 integer read-write
Once the lower threshold of utilization is passed, the number of seconds it should stay there is defined here.
               dBAProfile_NailedUpGroup 1.3.6.1.4.1.529.23.71.1.1.35 integer read-write
Nailed-up group letter. This is a group or number field as defined in lcdparam.h.
               dBAProfile_CallPassword 1.3.6.1.4.1.529.23.71.1.1.36 displaystring read-write
DBA call password authenticated against port's password on receiver side. Ignored if port's password is not defined.
               dBAProfile_DbaPriNumberingPlanId 1.3.6.1.4.1.529.23.71.1.1.37 integer read-write
PRI Called Party element's Numbering-Plan-ID value for outgoing T1-to-PRI calls.
               dBAProfile_Action_o 1.3.6.1.4.1.529.23.71.1.1.38 integer read-write
Enumeration: 'deleteProfile': 3, 'createProfile': 2, 'noAction': 1.
       mibdBAProfile_TimerPeriodParametersTable 1.3.6.1.4.1.529.23.71.2 no-access
A list of mibdBAProfile__timer_period_parameters profile entries.
           mibdBAProfile_TimerPeriodParametersEntry 1.3.6.1.4.1.529.23.71.2.1 no-access
A mibdBAProfile__timer_period_parameters entry containing objects that maps to the parameters of mibdBAProfile__timer_period_parameters profile.
               dBAProfile_TimerPeriodParameters_Shelf_o 1.3.6.1.4.1.529.23.71.2.1.1 integer read-only
               dBAProfile_TimerPeriodParameters_Slot_o 1.3.6.1.4.1.529.23.71.2.1.2 integer read-only
               dBAProfile_TimerPeriodParameters_Item_o 1.3.6.1.4.1.529.23.71.2.1.3 integer read-only
               dBAProfile_TimerPeriodParameters_LogicalItem_o 1.3.6.1.4.1.529.23.71.2.1.4 integer read-only
               dBAProfile_TimerPeriodParameters_Index_o 1.3.6.1.4.1.529.23.71.2.1.5 integer read-only
               dBAProfile_TimerPeriodParameters_oActiv 1.3.6.1.4.1.529.23.71.2.1.6 integer read-write
Like the other sub-structures above, the number of time-periods actually used is variable. Therefore, this is an indication within each structure of usage. Enumeration: 'disabled': 1, 'enabled': 2, 'shutdown': 3.
               dBAProfile_TimerPeriodParameters_StartingTime 1.3.6.1.4.1.529.23.71.2.1.7 integer read-write
Each time period has a starting time, and an ending time (which is implicit by the next starting time specified in another structure). The starting time is specified internally as the number of seconds after midnight, where midnight itself has a value of zero.
               dBAProfile_TimerPeriodParameters_MinimumChannelCount 1.3.6.1.4.1.529.23.71.2.1.8 integer read-write
The smallest number of channels to use during this time period.
               dBAProfile_TimerPeriodParameters_MaximumChannelCount 1.3.6.1.4.1.529.23.71.2.1.9 integer read-write
The maximum number of channels to use during this time period.
               dBAProfile_TimerPeriodParameters_TargetUtilization 1.3.6.1.4.1.529.23.71.2.1.10 integer read-write
The percentage utilization to aim for. This is used as a parameter to the bandwidth heuristics.
               dBAProfile_TimerPeriodParameters_X25chanTargetUtilization 1.3.6.1.4.1.529.23.71.2.1.11 integer read-write
The percentage utilization to aim for. This is used as a parameter to the bandwidth heuristics.