ASCEND-MIBCLTM-MIB: View SNMP OID List / Download MIB

VENDOR: ASCEND COMMUNICATIONS INC.


 Home MIB: ASCEND-MIBCLTM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 mibcltmCmd 1.3.6.1.4.1.529.23.66
       mibcltmCmdTable 1.3.6.1.4.1.529.23.66.1 no-access
A list of mibcltmCmd profile entries.
           mibcltmCmdEntry 1.3.6.1.4.1.529.23.66.1.1 no-access
A mibcltmCmd entry containing objects that maps to the parameters of mibcltmCmd profile.
               cltmCmd_Index_o 1.3.6.1.4.1.529.23.66.1.1.1 integer read-only
               cltmCmd_CltmSlot 1.3.6.1.4.1.529.23.66.1.1.2 integer read-only
Identify the CLTM slot within the system. Enumeration: 'slot11': 12, 'slot10': 11, 'slot13': 14, 'slot12': 13, 'slot15': 16, 'slot14': 15, 'slot16': 17, 'anySlot': 1, 'slot1': 2, 'slot3': 4, 'slot2': 3, 'slot5': 6, 'slot4': 5, 'slot7': 8, 'slot6': 7.
               cltmCmd_TestTimeStamp 1.3.6.1.4.1.529.23.66.1.1.3 integer read-only
Value of the sysUpTime when the last test command was issued. This parameter is cleared when any of the test parameters are changed.
               cltmCmd_TestSequence 1.3.6.1.4.1.529.23.66.1.1.4 integer read-only
Sequence of the last issued test command.
               cltmCmd_TestOperation 1.3.6.1.4.1.529.23.66.1.1.5 integer read-write
The current operation that is active on the CLT Module. Defaultls to 'none'. Set to 'none' to stop the test procedure. Enumeration: 'detRingerTest': 25, 'toneSend': 12, 'dmmLbalTest': 35, 'btapTest': 27, 'tdrGet': 15, 'voiceDetTest': 28, 'cltmDownload': 18, 'dmmDcdelTest': 19, 'measVoiceTest': 38, 'measDtaTest': 39, 'cltmVersion': 17, 'lineSignsTest': 5, 'lineInlsTest': 3, 'dmmAllTest': 21, 'lineShortlocTest': 30, 'toneRecv': 13, 'cltmReset': 16, 'txTraceToneTest': 23, 'dmmCapeTest': 20, 'detAturTest': 26, 'dmmSoakTest': 36, 'setBypassTest': 32, 'detaptorTest': 40, 'lineImpstartTest': 8, 'lineLpresTest': 6, 'lineCldetTest': 7, 'sendVoiceTest': 37, 'splitterDetectTest': 33, 'dmmAcdelTest': 34, 'dmmTest': 2, 'lineImpreadTest': 10, 'setResponderTest': 31, 'none': 1, 'tdrSet': 14, 'lineImpstopTest': 9, 'lineBgnsTest': 4, 'stopToneTest': 24, 'calibTest': 11, 'txCtrlToneTest': 22, 'lineFcllocTest': 29.
               cltmCmd_DmmType 1.3.6.1.4.1.529.23.66.1.1.6 integer read-write
DMM Measurement Type. Enumeration: 'capacitance': 4, 'acVoltage': 3, 'resistance': 1, 'dcVoltage': 2.
               cltmCmd_DmmLead 1.3.6.1.4.1.529.23.66.1.1.7 integer read-write
DMM Measurement Leads. Enumeration: 'ringSleeve': 3, 'tipSleeve': 2, 'tipRing': 1.
               cltmCmd_BackgroundNoiseFilter 1.3.6.1.4.1.529.23.66.1.1.8 integer read-write
Line Filter Type for Background Noise Test. Enumeration: 'e': 2, 'g': 4, 'psd': 1, 'f': 3.
               cltmCmd_BackgroundNoiseTermination 1.3.6.1.4.1.529.23.66.1.1.9 integer read-write
Line Termination Type for Background Noise Test. Enumeration: 'term135': 2, 'term100': 1, 'bridge100': 3, 'bridge135': 4.
               cltmCmd_LoopResistanceUnit 1.3.6.1.4.1.529.23.66.1.1.10 integer read-write
Measurement System for Loop Resistance Test. Enumeration: 'metric': 1, 'english': 2.
               cltmCmd_LoopResistanceTemp 1.3.6.1.4.1.529.23.66.1.1.11 integer read-write
Line Temperature for Loop Resistance Test. Assigned in degree celsius/fahrenheit.
               cltmCmd_ImpulseNoiseStartThresh 1.3.6.1.4.1.529.23.66.1.1.12 integer read-write
Threshold for Impulse Noise Test. The Range is 50-100 dBrm.
               cltmCmd_ImpulseNoiseStartDelta 1.3.6.1.4.1.529.23.66.1.1.13 integer read-write
Delta Value for Impulse Noise Test. The delta range is 2-6 dB
               cltmCmd_ImpulseNoiseStartMaxCount 1.3.6.1.4.1.529.23.66.1.1.14 integer read-write
Max Count for Impulse Noise Test. The range of the value is 1-1999.
               cltmCmd_ImpulseNoiseStartDeadTime 1.3.6.1.4.1.529.23.66.1.1.15 integer read-write
Dead Time Value for Impulse Noise Start Test. The value is assigned in 0.1 ms increments.
               cltmCmd_ImpulseNoiseStartTimer 1.3.6.1.4.1.529.23.66.1.1.16 integer read-write
Timer values for Impulse Noise Start Test. The value is assigned in 1 minute increment.
               cltmCmd_CalibrationType 1.3.6.1.4.1.529.23.66.1.1.17 integer read-write
Calibration Type Enumeration: 'insertionLoss': 1, 'backgroundNoise': 2.
               cltmCmd_ToneSendFreq 1.3.6.1.4.1.529.23.66.1.1.18 integer read-write
Tone Send Frequency in KHz.
               cltmCmd_ToneSendLevel 1.3.6.1.4.1.529.23.66.1.1.19 integer read-write
Tone Send Level in dBm.
               cltmCmd_ToneSendPeriod 1.3.6.1.4.1.529.23.66.1.1.20 integer read-write
Amount of time a tone is sent (1-20 Minutes).
               cltmCmd_TdrUnit 1.3.6.1.4.1.529.23.66.1.1.21 integer read-write
Measurement System for TDR Test. Enumeration: 'metric': 1, 'english': 2.
               cltmCmd_TdrGauge 1.3.6.1.4.1.529.23.66.1.1.22 integer read-write
TDR gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.
               cltmCmd_TdrVp 1.3.6.1.4.1.529.23.66.1.1.23 integer read-write
TDR VP as percentage of the speed of light.
               cltmCmd_TdrAvg 1.3.6.1.4.1.529.23.66.1.1.24 integer read-write
Number of trials to get the avarage.
               cltmCmd_TdrGetType 1.3.6.1.4.1.529.23.66.1.1.25 integer read-write
TDR Test Range Measurement Type. If set to automatic cltmCmdTdrStartLen and cltmCmdTdrMeasureLen do not need to be set. Enumeration: 'manual': 2, 'automatic': 1.
               cltmCmd_TdrStartDistance 1.3.6.1.4.1.529.23.66.1.1.26 integer read-write
TDR Start Length for MANUAL mode, the value is given in feet (15..20000) for the English system and cm (460..609750) for the metric system.
               cltmCmd_TdrMeasurementLength 1.3.6.1.4.1.529.23.66.1.1.27 integer read-write
TDR Measurement Length for MANUAL mode, the value is given in feet (300..20000) for the English system and cm (9150..609750) for the metric system.
               cltmCmd_DmmdcdPeriod 1.3.6.1.4.1.529.23.66.1.1.28 integer read-write
Amount of time measurement is made (0,1-5 100ms;0=MAX).
               cltmCmd_DmmdcdVoltage 1.3.6.1.4.1.529.23.66.1.1.29 integer read-write
Test voltage to be used (-230 to 230 Volts).
               cltmCmd_DmmdcdImpedance 1.3.6.1.4.1.529.23.66.1.1.30 integer read-write
Output Impedance to be used (10 to 1000 Kohms).
               cltmCmd_DmmcapPeriod 1.3.6.1.4.1.529.23.66.1.1.31 integer read-write
Amount of time measurement is made (0,1-5 100ms;0=MAX).
               cltmCmd_DmmallType 1.3.6.1.4.1.529.23.66.1.1.32 integer read-write
DMM Measurement Type. Enumeration: 'capacitance': 4, 'acVoltage': 3, 'resistance': 1, 'dcVoltage': 2.
               cltmCmd_DmmallPeriod 1.3.6.1.4.1.529.23.66.1.1.33 integer read-write
Amount of time measurement is made (0,1-5 100ms;0=MAX).
               cltmCmd_DmmallInputImp 1.3.6.1.4.1.529.23.66.1.1.34 integer read-write
Input Impedance (100, 1000 Kohm).
               cltmCmd_CtoneType 1.3.6.1.4.1.529.23.66.1.1.35 integer read-write
Control tone, type of DSL service (ADSL, GLITE). Enumeration: 'adsl': 1, 'glite': 2.
               cltmCmd_CtoneTone 1.3.6.1.4.1.529.23.66.1.1.36 integer read-write
Control tone, type of Tone (QUIET, RESTORE). Enumeration: 'restore': 2, 'quiet': 1.
               cltmCmd_TtoneLead 1.3.6.1.4.1.529.23.66.1.1.37 integer read-write
trace tone, Measurement Leads. Enumeration: 'ringSleeve': 3, 'tipSleeve': 2, 'tipRing': 1.
               cltmCmd_TtoneLevel 1.3.6.1.4.1.529.23.66.1.1.38 integer read-write
trace tone, Tone Send Level in dBm.
               cltmCmd_TtonePeriod 1.3.6.1.4.1.529.23.66.1.1.39 integer read-write
trace tone, Amount of time a tone is sent (1-20 Minutes).
               cltmCmd_BtapStartLength 1.3.6.1.4.1.529.23.66.1.1.40 integer read-write
Measurement start length (15 - 20000 ft. or 5 - 6097 meter).
               cltmCmd_BtapMeasureLength 1.3.6.1.4.1.529.23.66.1.1.41 integer read-write
Measurement length (100 - 20000 ft. or 32 - 6097 meter).
               cltmCmd_Action_o 1.3.6.1.4.1.529.23.66.1.1.42 integer read-write
Enumeration: 'deleteProfile': 3, 'createProfile': 2, 'noAction': 1.
               cltmCmd_FcllocUnit 1.3.6.1.4.1.529.23.66.1.1.43 integer read-write
Measurement System for FCLLOC Test. Enumeration: 'metric': 1, 'english': 2.
               cltmCmd_FcllocGauge 1.3.6.1.4.1.529.23.66.1.1.44 integer read-write
FCLLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.
               cltmCmd_ShortlocUnit 1.3.6.1.4.1.529.23.66.1.1.45 integer read-write
Measurement System for SHORTLOC Test. Enumeration: 'metric': 1, 'english': 2.
               cltmCmd_ShortlocGauge 1.3.6.1.4.1.529.23.66.1.1.46 integer read-write
SHORTLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.
               cltmCmd_ShortlocType 1.3.6.1.4.1.529.23.66.1.1.47 integer read-write
SHORTLOC test type. Enumeration: 'noDetect': 2, 'detect': 1.