ASCEND-MIBATMSIG-MIB: View SNMP OID List / Download MIB
VENDOR: ASCEND COMMUNICATIONS INC.
Home | MIB: ASCEND-MIBATMSIG-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
mibatmIntfSigParams | 1.3.6.1.4.1.529.23.52 | |||
mibatmIntfSigParamsTable | 1.3.6.1.4.1.529.23.52.1 | no-access |
A list of mibatmIntfSigParams profile entries. |
|
1.3.6.1.4.1.529.23.52.1.1 | no-access |
A mibatmIntfSigParams entry containing objects that maps to the parameters of mibatmIntfSigParams profile. |
||
atmIntfSigParams_Shelf_o | 1.3.6.1.4.1.529.23.52.1.1.1 | integer | read-only | |
atmIntfSigParams_Slot_o | 1.3.6.1.4.1.529.23.52.1.1.2 | integer | read-only | |
atmIntfSigParams_Item_o | 1.3.6.1.4.1.529.23.52.1.1.3 | integer | read-only | |
atmIntfSigParams_LogicalItem_o | 1.3.6.1.4.1.529.23.52.1.1.4 | integer | read-only | |
atmIntfSigParams_Address_PhysicalAddress_Shelf | 1.3.6.1.4.1.529.23.52.1.1.5 | integer | read-write |
The number of the shelf that the addressed physical device resides on. Enumeration: 'anyShelf': 1, 'shelf2': 3, 'shelf3': 4, 'shelf1': 2, 'shelf6': 7, 'shelf7': 8, 'shelf4': 5, 'shelf5': 6, 'shelf8': 9, 'shelf9': 10. |
atmIntfSigParams_Address_PhysicalAddress_Slot | 1.3.6.1.4.1.529.23.52.1.1.6 | integer | read-write |
The number of the slot that the addressed physical device resides on. Enumeration: 'aLim': 55, 'bLim': 56, 'trunkModule2': 46, 'slot36': 37, 'firstControlModule': 53, 'trunkModule1': 45, 'rightController': 50, 'slot28': 29, 'slot29': 30, 'slot24': 25, 'slot25': 26, 'slot26': 27, 'slot27': 28, 'slot20': 21, 'slot21': 22, 'slot22': 23, 'slot23': 24, 'slotPrimary': 59, 'cLim': 57, 'slot40': 41, 'secondControlModule': 54, 'leftController': 49, 'slot39': 40, 'controlModule': 51, 'slot9': 10, 'slot8': 9, 'controller': 42, 'slot38': 39, 'slot1': 2, 'slot3': 4, 'slot2': 3, 'slot5': 6, 'slot4': 5, 'slot7': 8, 'slot6': 7, 'slot11': 12, 'slot10': 11, 'slot13': 14, 'slot12': 13, 'slot15': 16, 'slot14': 15, 'slot17': 18, 'slot16': 17, 'slot19': 20, 'slot18': 19, 'slot31': 32, 'slot30': 31, 'slot37': 38, 'anySlot': 1, 'slot35': 36, 'slot34': 35, 'slot33': 34, 'dLim': 58, 'slot32': 33. |
atmIntfSigParams_Address_PhysicalAddress_ItemNumber | 1.3.6.1.4.1.529.23.52.1.1.7 | integer | read-write |
A number that specifies an addressable entity within the context of shelf and slot. |
atmIntfSigParams_Address_LogicalItem | 1.3.6.1.4.1.529.23.52.1.1.8 | integer | read-write |
A number that specifies an addressable logical entity within the context of a physical address. |
atmIntfSigParams_Q2931Options_MaxRestart | 1.3.6.1.4.1.529.23.52.1.1.9 | integer | read-write |
Maximum number of unacknowledged tx RESTART. |
atmIntfSigParams_Q2931Options_MaxStatenq | 1.3.6.1.4.1.529.23.52.1.1.10 | integer | read-write |
Maximum number of unacknowledged tx STATUS ENQ. |
atmIntfSigParams_Q2931Options_T301Ms | 1.3.6.1.4.1.529.23.52.1.1.11 | integer | read-write |
Timer (in msec) for alerting supervision function. This timer is started on receipt of ALERT in Call received/delivered state and stopped when CONNECT is received. |
atmIntfSigParams_Q2931Options_T303Ms | 1.3.6.1.4.1.529.23.52.1.1.12 | integer | read-write |
Timer (in msec) for a response after SETUP is sent. This timer is stopped when the CONNECT, CALL PROCEEDING, or RELEASE COMPLETE is received. |
atmIntfSigParams_Q2931Options_T306Ms | 1.3.6.1.4.1.529.23.52.1.1.13 | integer | read-write |
Timer (in msec) for a RELEASE_COMPLETE to be received after a release has been sent. |
atmIntfSigParams_Q2931Options_T308Ms | 1.3.6.1.4.1.529.23.52.1.1.14 | integer | read-write |
Timer (in msec) for a response after RELEASE is sent. This is a release indication timer. This timer is started when the RELEASE message is sent and normally is stopped when the RELEASE or RELEASE COMPLETE is received. |
atmIntfSigParams_Q2931Options_T309Ms | 1.3.6.1.4.1.529.23.52.1.1.15 | integer | read-write |
Timer (in msec) for Q.SAAL to reconnect. After this time, calls are dropped. When set to 0, a default value based on an ATM signaling protocol will be used. |
atmIntfSigParams_Q2931Options_T310Ms | 1.3.6.1.4.1.529.23.52.1.1.16 | integer | read-write |
Timer (in msec) for a response after SETUP is received. Also called the CALL PROCEEDING timer. |
atmIntfSigParams_Q2931Options_T313Ms | 1.3.6.1.4.1.529.23.52.1.1.17 | integer | read-write |
Timer (in msec) for a response after CONNECT is sent. Also called the connect request timer. It is started when the CONNECT is sent and stopped when the CONNECT ACKNOWLEDGE is recieved. |
atmIntfSigParams_Q2931Options_T316Ms | 1.3.6.1.4.1.529.23.52.1.1.18 | integer | read-write |
Timer (in msec) for a response after RESTART is sent. Also called the restart request timer. It is started when the RESTART is sent and stopped when the RESTART ACKNOWLEDGE is recieved. |
atmIntfSigParams_Q2931Options_T317Ms | 1.3.6.1.4.1.529.23.52.1.1.19 | integer | read-write |
Timer (in msec) for internal clearing of call references. This timer is started as a result of a restart and cleared when all the internal call references are cleared. Should be less than the the likely value of T316 of the peer. |
atmIntfSigParams_Q2931Options_T322Ms | 1.3.6.1.4.1.529.23.52.1.1.20 | integer | read-write |
Timer (in msec) for a response after STATUS ENQ is sent. |
atmIntfSigParams_Q2931Options_T331Ms | 1.3.6.1.4.1.529.23.52.1.1.21 | integer | read-write |
Timer (in msec) for internal clearing of call references. |
atmIntfSigParams_Q2931Options_T333Ms | 1.3.6.1.4.1.529.23.52.1.1.22 | integer | read-write |
Timer (in msec) for internal clearing of call references. |
atmIntfSigParams_Q2931Options_T397Ms | 1.3.6.1.4.1.529.23.52.1.1.23 | integer | read-write |
Timer (in msec) for internal clearing of call references. |
atmIntfSigParams_Q2931Options_T398Ms | 1.3.6.1.4.1.529.23.52.1.1.24 | integer | read-write |
Timer (in msec) for receipt of a response to a DROP PARTY that was sent. |
atmIntfSigParams_Q2931Options_T399Ms | 1.3.6.1.4.1.529.23.52.1.1.25 | integer | read-write |
Timer (in msec) for receipt of a response to an ADD PARTY that was sent. |
atmIntfSigParams_Q2931Options_SaalRetryMs | 1.3.6.1.4.1.529.23.52.1.1.26 | integer | read-write |
Timer value for retrying AAL_ESTABLISH messages. |
atmIntfSigParams_Q2931Options_T303NumReties | 1.3.6.1.4.1.529.23.52.1.1.27 | integer | read-write |
Number of times SETUP could be resent in case of T303 timer expiry. |
atmIntfSigParams_Q2931Options_T308NumRetries | 1.3.6.1.4.1.529.23.52.1.1.28 | integer | read-write |
Number of times RELEASE could be sent in case of T308 timer expiry. |
atmIntfSigParams_Q2931Options_T316NumRetries | 1.3.6.1.4.1.529.23.52.1.1.29 | integer | read-write |
Number of times RESTART could be sent in case RESTART ACK is not received withinn T316 timer expiry. |
atmIntfSigParams_Q2931Options_T322NumRetries | 1.3.6.1.4.1.529.23.52.1.1.30 | integer | read-write |
Number of times STAT ENQ could be sent before a response is received within the T322 timer expiry. |
atmIntfSigParams_Q2931Options_T331NumRetries | 1.3.6.1.4.1.529.23.52.1.1.31 | integer | read-write | |
atmIntfSigParams_Q2931Options_AssignVpiVci | 1.3.6.1.4.1.529.23.52.1.1.32 | integer | read-write |
In the case of UNI4.0 and PNNI this parameter specifies who assigns the VPI/VCI. TRUE will allow the local stack and FALSE will let the partner stack to assign. Enumeration: 'yes': 2, 'no': 1. |
atmIntfSigParams_QsaalOptions_WindowSize | 1.3.6.1.4.1.529.23.52.1.1.33 | integer | read-write |
Q.SAAL window size |
atmIntfSigParams_QsaalOptions_MaxCc | 1.3.6.1.4.1.529.23.52.1.1.34 | integer | read-write |
Maximum number of control PDU (BGN, END, RESYNC) retransmissions. |
atmIntfSigParams_QsaalOptions_MaxPd | 1.3.6.1.4.1.529.23.52.1.1.35 | integer | read-write |
Maximum number of Sequenced data PDU's between poll. |
atmIntfSigParams_QsaalOptions_MaxStat | 1.3.6.1.4.1.529.23.52.1.1.36 | integer | read-write |
Maximum length of STAT PDU. |
atmIntfSigParams_QsaalOptions_TccMs | 1.3.6.1.4.1.529.23.52.1.1.37 | integer | read-write |
Retry time (in msec) for control PDU's(BGN, END, RESYNC). |
atmIntfSigParams_QsaalOptions_TpollMs | 1.3.6.1.4.1.529.23.52.1.1.38 | integer | read-write |
Poll sent (in msec) when active. When set to 0, a default value based on an ATM signaling protocol will be used. |
atmIntfSigParams_QsaalOptions_TkeepaliveMs | 1.3.6.1.4.1.529.23.52.1.1.39 | integer | read-write |
Poll sent (in msec) when in transient state. When set to 0, a default value based on an ATM signaling protocol will be used. |
atmIntfSigParams_QsaalOptions_TnoresponseMs | 1.3.6.1.4.1.529.23.52.1.1.40 | integer | read-write |
STAT received at least this period(in msec). When set to 0, a default value based on an ATM signaling protocol will be used. |
atmIntfSigParams_QsaalOptions_TidleMs | 1.3.6.1.4.1.529.23.52.1.1.41 | integer | read-write |
Poll sent (in msec) when idle -- UNI 3.1, only. |
atmIntfSigParams_QsaalOptions_PollAfterRetransmission | 1.3.6.1.4.1.529.23.52.1.1.42 | integer | read-write |
Specifies after retransmitting PDUs whether a POLL must be sent before sending any further PDUs. Enumeration: 'yes': 2, 'no': 1. |
atmIntfSigParams_QsaalOptions_RepeatUstat | 1.3.6.1.4.1.529.23.52.1.1.43 | integer | read-write |
Specifies whether two USTAT messages should be sent each time it is required to be sent. Enumeration: 'yes': 2, 'no': 1. |
atmIntfSigParams_QsaalOptions_UstatRspToPoll | 1.3.6.1.4.1.529.23.52.1.1.44 | integer | read-write |
Specifies whether a USTAT should be sent in response to a POLL indicating an out of sequence PDU. Enumeration: 'yes': 2, 'no': 1. |
atmIntfSigParams_Action_o | 1.3.6.1.4.1.529.23.52.1.1.45 | integer | read-write |
Enumeration: 'deleteProfile': 3, 'createProfile': 2, 'noAction': 1. |