Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 mibatmInterfaceProfile 1.3.6.1.4.1.529.23.40
       mibatmInterfaceProfileTable 1.3.6.1.4.1.529.23.40.1 no-access
A list of mibatmInterfaceProfile profile entries.
           mibatmInterfaceProfileEntry 1.3.6.1.4.1.529.23.40.1.1 no-access
A mibatmInterfaceProfile entry containing objects that maps to the parameters of mibatmInterfaceProfile profile.
               atmInterfaceProfile_Shelf_o 1.3.6.1.4.1.529.23.40.1.1.1 integer read-only
               atmInterfaceProfile_Slot_o 1.3.6.1.4.1.529.23.40.1.1.2 integer read-only
               atmInterfaceProfile_Item_o 1.3.6.1.4.1.529.23.40.1.1.3 integer read-only
               atmInterfaceProfile_LogicalItem_o 1.3.6.1.4.1.529.23.40.1.1.4 integer read-only
               atmInterfaceProfile_InterfaceAddress_PhysicalAddress_Shelf 1.3.6.1.4.1.529.23.40.1.1.5 integer read-write
The number of the shelf that the addressed physical device resides on. Enumeration: 'anyShelf': 1, 'shelf2': 3, 'shelf3': 4, 'shelf1': 2, 'shelf6': 7, 'shelf7': 8, 'shelf4': 5, 'shelf5': 6, 'shelf8': 9, 'shelf9': 10.
               atmInterfaceProfile_InterfaceAddress_PhysicalAddress_Slot 1.3.6.1.4.1.529.23.40.1.1.6 integer read-write
The number of the slot that the addressed physical device resides on. Enumeration: 'aLim': 55, 'bLim': 56, 'trunkModule2': 46, 'slot36': 37, 'firstControlModule': 53, 'trunkModule1': 45, 'rightController': 50, 'slot28': 29, 'slot29': 30, 'slot24': 25, 'slot25': 26, 'slot26': 27, 'slot27': 28, 'slot20': 21, 'slot21': 22, 'slot22': 23, 'slot23': 24, 'slotPrimary': 59, 'cLim': 57, 'slot40': 41, 'secondControlModule': 54, 'leftController': 49, 'slot39': 40, 'controlModule': 51, 'slot9': 10, 'slot8': 9, 'controller': 42, 'slot38': 39, 'slot1': 2, 'slot3': 4, 'slot2': 3, 'slot5': 6, 'slot4': 5, 'slot7': 8, 'slot6': 7, 'slot11': 12, 'slot10': 11, 'slot13': 14, 'slot12': 13, 'slot15': 16, 'slot14': 15, 'slot17': 18, 'slot16': 17, 'slot19': 20, 'slot18': 19, 'slot31': 32, 'slot30': 31, 'slot37': 38, 'anySlot': 1, 'slot35': 36, 'slot34': 35, 'slot33': 34, 'dLim': 58, 'slot32': 33.
               atmInterfaceProfile_InterfaceAddress_PhysicalAddress_ItemNumber 1.3.6.1.4.1.529.23.40.1.1.7 integer read-write
A number that specifies an addressable entity within the context of shelf and slot.
               atmInterfaceProfile_InterfaceAddress_LogicalItem 1.3.6.1.4.1.529.23.40.1.1.8 integer read-write
A number that specifies an addressable logical entity within the context of a physical address.
               atmInterfaceProfile_Name 1.3.6.1.4.1.529.23.40.1.1.9 displaystring read-write
Name of ATM Interface.
               atmInterfaceProfile_SvcOptions_Enabled 1.3.6.1.4.1.529.23.40.1.1.10 integer read-write
SVC signalling (Q.93b) is enabled on this link. Enumeration: 'yes': 2, 'no': 1.
               atmInterfaceProfile_SvcOptions_AtmProtocol 1.3.6.1.4.1.529.23.40.1.1.11 integer read-write
ATM protocol on this link. Enumeration: 'uni30': 2, 'uni31': 3.
               atmInterfaceProfile_SvcOptions_AtmAddress_NumberingPlan 1.3.6.1.4.1.529.23.40.1.1.12 integer read-write
Numbering plan for an SVC address Enumeration: 'x121': 9, 'unknown': 5, 'aesa': 3, 'undefined': 1, 'isdn': 2.
               atmInterfaceProfile_SvcOptions_AtmAddress_E164NativeAddress 1.3.6.1.4.1.529.23.40.1.1.13 displaystring read-write
An SVC address in a native E.164 format.
               atmInterfaceProfile_SvcOptions_AtmAddress_AesaAddress_Format 1.3.6.1.4.1.529.23.40.1.1.14 integer read-write
An AESA address format used to define this SVC address. Enumeration: 'icdAesa': 6, 'e164Aesa': 4, 'dccAesa': 2, 'undefined': 1, 'customAesa': 5.
               atmInterfaceProfile_SvcOptions_AtmAddress_AesaAddress_IdpPortion_Afi 1.3.6.1.4.1.529.23.40.1.1.15 displaystring read-write
An Authority and Format Identifier(AFI) for AESA address. Must be defined for every AESA address.
               atmInterfaceProfile_SvcOptions_AtmAddress_AesaAddress_IdpPortion_Idi 1.3.6.1.4.1.529.23.40.1.1.16 displaystring read-write
An Initial Domain Identifier (IDI) portion of the AESA address.
               atmInterfaceProfile_SvcOptions_AtmAddress_AesaAddress_DspPortion_HoDsp 1.3.6.1.4.1.529.23.40.1.1.17 displaystring read-write
A High-Order Domain-Specific Part of AESA address. The IDP portion determine the format of the HO-DSP.
               atmInterfaceProfile_SvcOptions_AtmAddress_AesaAddress_DspPortion_Esi 1.3.6.1.4.1.529.23.40.1.1.18 displaystring read-write
An End System Identifier (ESI) which uniquely identifies the end system within the specified subnetwork.
               atmInterfaceProfile_SvcOptions_AtmAddress_AesaAddress_DspPortion_Sel 1.3.6.1.4.1.529.23.40.1.1.19 displaystring read-write
A selector (SEL) field that may be used by the end system.
               atmInterfaceProfile_SvcOptions_InsertCallingPartyAddr 1.3.6.1.4.1.529.23.40.1.1.20 integer read-write
Insert ATM address of this interface in calling party address IE during call setup. Enumeration: 'yes': 2, 'no': 1.
               atmInterfaceProfile_SvcOptions_Q93bOptions_MaxRestart 1.3.6.1.4.1.529.23.40.1.1.21 integer read-write
Maximum number of unacknowledged tx RESTART.
               atmInterfaceProfile_SvcOptions_Q93bOptions_MaxStatenq 1.3.6.1.4.1.529.23.40.1.1.22 integer read-write
Maximum number of unacknowledged tx STATUS ENQ.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T301Ms 1.3.6.1.4.1.529.23.40.1.1.23 integer read-write
Timer (in msec) for alerting supervision function. This timer is started on receipt of ALERT in Call received/delivered state and stopped when CONNECT is received.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T303Ms 1.3.6.1.4.1.529.23.40.1.1.24 integer read-write
Timer (in msec) for a response after SETUP is sent. This timer is stopped when the CONNECT, CALL PROCEEDING, or RELEASE COMPLETE is received.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T306Ms 1.3.6.1.4.1.529.23.40.1.1.25 integer read-write
Timer (in msec) for a RELEASE_COMPLETE to be received after a release has been sent.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T308Ms 1.3.6.1.4.1.529.23.40.1.1.26 integer read-write
Timer (in msec) for a response after RELEASE is sent. This is a release indication timer. This timer is started when the RELEASE message is sent and normally is stopped when the RELEASE or RELEASE COMPLETE is received.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T309Ms 1.3.6.1.4.1.529.23.40.1.1.27 integer read-write
Timer (in msec) for Q.SAAL to reconnect. After this time, calls are dropped. When set to 0, a default value based on an ATM signaling protocol will be used.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T310Ms 1.3.6.1.4.1.529.23.40.1.1.28 integer read-write
Timer (in msec) for a response after SETUP is received. Also called the CALL PROCEEDING timer.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T313Ms 1.3.6.1.4.1.529.23.40.1.1.29 integer read-write
Timer (in msec) for a response after CONNECT is sent. Also called the connect request timer. It is started when the CONNECT is sent and stopped when the CONNECT ACKNOWLEDGE is recieved.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T316Ms 1.3.6.1.4.1.529.23.40.1.1.30 integer read-write
Timer (in msec) for a response after RESTART is sent. Also called the restart request timer. It is started when the RESTART is sent and stopped when the RESTART ACKNOWLEDGE is recieved.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T317Ms 1.3.6.1.4.1.529.23.40.1.1.31 integer read-write
Timer (in msec) for internal clearing of call references. This timer is started as a result of a restart and cleared when all the internal call references are cleared. Should be less than the the likely value of T316 of the peer.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T322Ms 1.3.6.1.4.1.529.23.40.1.1.32 integer read-write
Timer (in msec) for a response after STATUS ENQ is sent.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T331Ms 1.3.6.1.4.1.529.23.40.1.1.33 integer read-write
Timer (in msec) for internal clearing of call references.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T333Ms 1.3.6.1.4.1.529.23.40.1.1.34 integer read-write
Timer (in msec) for internal clearing of call references.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T397Ms 1.3.6.1.4.1.529.23.40.1.1.35 integer read-write
Timer (in msec) for internal clearing of call references.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T398Ms 1.3.6.1.4.1.529.23.40.1.1.36 integer read-write
Timer (in msec) for receipt of a response to a DROP PARTY that was sent.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T399Ms 1.3.6.1.4.1.529.23.40.1.1.37 integer read-write
Timer (in msec) for receipt of a response to an ADD PARTY that was sent.
               atmInterfaceProfile_SvcOptions_Q93bOptions_SaalRetryMs 1.3.6.1.4.1.529.23.40.1.1.38 integer read-write
Timer value for retrying AAL_ESTABLISH messages.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T303NumReties 1.3.6.1.4.1.529.23.40.1.1.39 integer read-write
Number of times SETUP could be resent in case of T303 timer expiry.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T308NumRetries 1.3.6.1.4.1.529.23.40.1.1.40 integer read-write
Number of times RELEASE could be sent in case of T308 timer expiry.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T316NumRetries 1.3.6.1.4.1.529.23.40.1.1.41 integer read-write
Number of times RESTART could be sent in case RESTART ACK is not received withinn T316 timer expiry.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T322NumRetries 1.3.6.1.4.1.529.23.40.1.1.42 integer read-write
Number of times STAT ENQ could be sent before a response is received within the T322 timer expiry.
               atmInterfaceProfile_SvcOptions_Q93bOptions_T331NumRetries 1.3.6.1.4.1.529.23.40.1.1.43 integer read-write
               atmInterfaceProfile_SvcOptions_Q93bOptions_AssignVpiVci 1.3.6.1.4.1.529.23.40.1.1.44 integer read-write
In the case of UNI4.0 and PNNI this parameter specifies who assigns the VPI/VCI. TRUE will allow the local stack and FALSE will let the partner stack to assign. Enumeration: 'yes': 2, 'no': 1.
               atmInterfaceProfile_SvcOptions_QsaalOptions_WindowSize 1.3.6.1.4.1.529.23.40.1.1.45 integer read-write
Q.SAAL window size
               atmInterfaceProfile_SvcOptions_QsaalOptions_MaxCc 1.3.6.1.4.1.529.23.40.1.1.46 integer read-write
Maximum number of control PDU (BGN, END, RESYNC) retransmissions.
               atmInterfaceProfile_SvcOptions_QsaalOptions_MaxPd 1.3.6.1.4.1.529.23.40.1.1.47 integer read-write
Maximum number of Sequenced data PDU's between poll.
               atmInterfaceProfile_SvcOptions_QsaalOptions_MaxStat 1.3.6.1.4.1.529.23.40.1.1.48 integer read-write
Maximum length of STAT PDU.
               atmInterfaceProfile_SvcOptions_QsaalOptions_TccMs 1.3.6.1.4.1.529.23.40.1.1.49 integer read-write
Retry time (in msec) for control PDU's(BGN, END, RESYNC).
               atmInterfaceProfile_SvcOptions_QsaalOptions_TpollMs 1.3.6.1.4.1.529.23.40.1.1.50 integer read-write
Poll sent (in msec) when active. When set to 0, a default value based on an ATM signaling protocol will be used.
               atmInterfaceProfile_SvcOptions_QsaalOptions_TkeepaliveMs 1.3.6.1.4.1.529.23.40.1.1.51 integer read-write
Poll sent (in msec) when in transient state. When set to 0, a default value based on an ATM signaling protocol will be used.
               atmInterfaceProfile_SvcOptions_QsaalOptions_TnoresponseMs 1.3.6.1.4.1.529.23.40.1.1.52 integer read-write
STAT received at least this period(in msec). When set to 0, a default value based on an ATM signaling protocol will be used.
               atmInterfaceProfile_SvcOptions_QsaalOptions_TidleMs 1.3.6.1.4.1.529.23.40.1.1.53 integer read-write
Poll sent (in msec) when idle -- UNI 3.1, only.
               atmInterfaceProfile_SvcOptions_QsaalOptions_PollAfterRetransmission 1.3.6.1.4.1.529.23.40.1.1.54 integer read-write
Specifies after retransmitting PDUs whether a POLL must be sent before sending any further PDUs. Enumeration: 'yes': 2, 'no': 1.
               atmInterfaceProfile_SvcOptions_QsaalOptions_RepeatUstat 1.3.6.1.4.1.529.23.40.1.1.55 integer read-write
Specifies whether two USTAT messages should be sent each time it is required to be sent. Enumeration: 'yes': 2, 'no': 1.
               atmInterfaceProfile_SvcOptions_QsaalOptions_UstatRspToPoll 1.3.6.1.4.1.529.23.40.1.1.56 integer read-write
Specifies whether a USTAT should be sent in response to a POLL indicating an out of sequence PDU. Enumeration: 'yes': 2, 'no': 1.
               atmInterfaceProfile_Action_o 1.3.6.1.4.1.529.23.40.1.1.57 integer read-write
Enumeration: 'deleteProfile': 3, 'createProfile': 2, 'noAction': 1.