ACD-DESC-MIB: View SNMP OID List / Download MIB
VENDOR: ACCEDIAN
Home | MIB: ACD-DESC-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
acdDesc | 1.3.6.1.4.1.22420.1.1 |
The Accedian Networks device Description MIB. |
||
acdDescNotifications | 1.3.6.1.4.1.22420.1.1.0 | |||
acdPowerLost | 1.3.6.1.4.1.22420.1.1.0.1 |
The SNMP trap that is generated by a unit when it detect a power lost. It's the equivalent of the 802.3ah dying gasp. |
||
acdDescCommercialName | 1.3.6.1.4.1.22420.1.1.1 | displaystring | read-only |
This string is to describe the type of device. |
acdDescMacBaseAddr | 1.3.6.1.4.1.22420.1.1.2 | macaddress | read-only |
This is the Base of the EtherNID MAC addresses. |
acdDescIdentifier | 1.3.6.1.4.1.22420.1.1.3 | displaystring | read-only |
Identifies the EtherNID on your network. |
acdDescFirmwareVersion | 1.3.6.1.4.1.22420.1.1.4 | displaystring | read-only |
Indicates the version of the firmware currently loaded. |
acdDescHardwareVersion | 1.3.6.1.4.1.22420.1.1.5 | displaystring | read-only |
Indicates the assembly ID of the hardware. |
acdDescSerialNumber | 1.3.6.1.4.1.22420.1.1.6 | displaystring | read-only |
Indicates the serial number. |
acdDescConnectorTable | 1.3.6.1.4.1.22420.1.1.10 | no-access |
Table of all connectors info |
|
1.3.6.1.4.1.22420.1.1.10.1 | no-access |
This is the product connector definition. |
||
acdDescConnectorID | 1.3.6.1.4.1.22420.1.1.10.1.1 | unsigned32 | no-access |
Unique value for each connector. Starting to one from left to right. |
acdDescConnectorName | 1.3.6.1.4.1.22420.1.1.10.1.2 | displaystring | read-only |
Identifies the connector on the silkscreen. |
acdDescConnectorType | 1.3.6.1.4.1.22420.1.1.10.1.3 | integer | read-only |
Describe the connector type, for instance an RJ-45 or an SFP. Enumeration: 'fiberST': 10, 'fiberSC': 8, 'telco': 11, 'fAUI': 6, 'mAUI': 7, 'fiberMIC': 9, 'mtrj': 12, 'db9': 4, 'rj45': 2, 'other': 1, 'hssdc': 13, 'rj45S': 3, 'bnc': 5, 'fiberLC': 14. |
acdDescConnectorPoESupport | 1.3.6.1.4.1.22420.1.1.10.1.4 | truthvalue | read-only |
This is to indicate if the port support PoE or not. |
acdDescPwrTable | 1.3.6.1.4.1.22420.1.1.11 | no-access |
Table of all Power Supplies |
|
1.3.6.1.4.1.22420.1.1.11.1 | no-access |
This is the product available power supplies information. |
||
acdDescPwrID | 1.3.6.1.4.1.22420.1.1.11.1.1 | unsigned32 | no-access |
Unique value for each power supply. |
acdDescPwrName | 1.3.6.1.4.1.22420.1.1.11.1.2 | displaystring | read-only |
Identifies the power supply. |
acdDescPwrType | 1.3.6.1.4.1.22420.1.1.11.1.3 | integer | read-only |
Describe the Power Supply type. Enumeration: 'pwrplus5volts': 1, 'pwrminus48volts': 2. |
acdDescPwrPresent | 1.3.6.1.4.1.22420.1.1.11.1.4 | truthvalue | read-only |
This is to indicate if the power supply is present or not. |
acdDescTsTable | 1.3.6.1.4.1.22420.1.1.12 | no-access |
Table of all Teperature Sensors. |
|
1.3.6.1.4.1.22420.1.1.12.1 | no-access |
This is the product available Temperature sensor information. |
||
acdDescTsID | 1.3.6.1.4.1.22420.1.1.12.1.1 | unsigned32 | no-access |
Unique value for each Temperature Sensor. |
acdDescTsCurrentTemp | 1.3.6.1.4.1.22420.1.1.12.1.2 | integer32 | read-only |
Current temperature in Celsius around the temperature sensor. |
acdDescTsFirstThres | 1.3.6.1.4.1.22420.1.1.12.1.3 | integer32 | read-only |
Temperature value in Celsius to declare this threshold crossed. |
acdDescTsFisrtThresPass | 1.3.6.1.4.1.22420.1.1.12.1.4 | truthvalue | read-only |
This is to indicate if the temperature cross the first threshold. |
acdDescTsSecondThres | 1.3.6.1.4.1.22420.1.1.12.1.5 | integer32 | read-only |
Temperature value in Celsius to declare this second threshold crossed. |
acdDescTsSecondThresPass | 1.3.6.1.4.1.22420.1.1.12.1.6 | truthvalue | read-only |
This is to indicate if the temperature cross the second threshold. |
acdDescMIBObjects | 1.3.6.1.4.1.22420.1.1.15 | |||
acdDescConformance | 1.3.6.1.4.1.22420.1.1.15.1 | |||
acdDescCompliances | 1.3.6.1.4.1.22420.1.1.15.1.1 | |||
acdAlarmCompliance | 1.3.6.1.4.1.22420.1.1.15.1.1.1 |
The compliance statement for support of the ACD-DESC-MIB module. |
||
acdDescGroups | 1.3.6.1.4.1.22420.1.1.15.1.2 | |||
acdDescGenGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.1 |
. |
||
acdDescConnectorGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.2 |
. |
||
acdDescPwrGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.3 |
. |
||
acdDescTsGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.4 |
. |
||
acdDescNotificationsGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.5 |
Objects for the Notifications group. |
||
acdDescCpuUsageCurrent | 1.3.6.1.4.1.22420.1.1.20 | gauge32 | read-only |
Indicates the current percentage of CPU usage. |
acdDescCpuUsageAverage15 | 1.3.6.1.4.1.22420.1.1.21 | gauge32 | read-only |
Indicates the average percentage of CPU usage over the last 15 seconds. This object range from (0..100). |
acdDescCpuUsageAverage30 | 1.3.6.1.4.1.22420.1.1.22 | gauge32 | read-only |
Indicates the average percentage of CPU usage over the last 30 seconds. This object range from (0..100). |
acdDescCpuUsageAverage60 | 1.3.6.1.4.1.22420.1.1.23 | gauge32 | read-only |
Indicates the average percentage of CPU usage over the last 60 seconds. This object range from (0..100). |
acdDescCpuUsageAverage900 | 1.3.6.1.4.1.22420.1.1.24 | gauge32 | read-only |
Indicates the average percentage of CPU usage over the last 900 seconds. This object range from (0..100). |