Zhone-PTP-MIB: View SNMP OID List / Download MIB

VENDOR: ZHONE TECHNOLOGIES


 Home MIB: Zhone-PTP-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
       zhonePtpObjectID 1.3.6.1.4.1.5504.4.17.1
           zhonePtpConfigTable 1.3.6.1.4.1.5504.4.17.1.1 no-access
Table of configuration values for the Precision Timing Protocol.
               zhonePtpConfigEntry 1.3.6.1.4.1.5504.4.17.1.1.1 no-access
Row in the PtpConfigTable
                   zhonePtpConfigIfIndex 1.3.6.1.4.1.5504.4.17.1.1.1.1 interfaceindex no-access
Index for this table.
                   zhonePtpConfigClockMode 1.3.6.1.4.1.5504.4.17.1.1.1.2 integer read-only
Describes the mode and function of this clock. Enumeration: 'forward': 5, 'slave': 2, 'boundary': 3, 'master': 1, 'transparent': 4.
                   zhonePtpConfigSyncMsgInterval 1.3.6.1.4.1.5504.4.17.1.1.1.3 integer32 read-only
Log of mean time interval between successive Sync messages when transmitted as multicast messages.
                   zhonePtpConfigAnnounceInterval 1.3.6.1.4.1.5504.4.17.1.1.1.4 integer32 read-only
Log of time, in seconds, to send announce messages.
                   zhonePtpConfigDelayReqInterval 1.3.6.1.4.1.5504.4.17.1.1.1.5 integer32 read-only
Log of minimum permitted mean time between successive Delay_Req messages sent by a slave to a specific port on the master.
                   zhonePtpConfigDomain1MS 1.3.6.1.4.1.5504.4.17.1.1.1.6 unsigned32 read-only
The domain for this PTP. If clockMode is boundary, then this is the domain for the slave port.
                   zhonePtpConfigVariance 1.3.6.1.4.1.5504.4.17.1.1.1.7 unsigned32 read-only
Log of variance used in determination of the best master clock.
                   zhonePtpConfigPriority1 1.3.6.1.4.1.5504.4.17.1.1.1.8 unsigned32 read-only
Precedence value used in best master algorithm, if master.
                   zhonePtpConfigPriority2 1.3.6.1.4.1.5504.4.17.1.1.1.9 unsigned32 read-only
Precedence used in best master determination, if master
                   zhonePtpConfigDomain2M 1.3.6.1.4.1.5504.4.17.1.1.1.10 integer32 read-only
If clockMode is boundary, then this is the domain for the master port. Otherwise, it is unused.
                   zhonePtpConfigRowStatus 1.3.6.1.4.1.5504.4.17.1.1.1.11 zhonerowstatus read-only
Row status for this table.
                   zhonePtpConfigIpIfIndex 1.3.6.1.4.1.5504.4.17.1.1.1.12 interfaceindex read-only
The management ip index on this system.
                   zhonePtpConfigAcceptableMaster1 1.3.6.1.4.1.5504.4.17.1.1.1.13 ipaddress read-only
First acceptable PTP master.
                   zhonePtpConfigAcceptableMaster2 1.3.6.1.4.1.5504.4.17.1.1.1.14 ipaddress read-only
Second acceptable PTP master.
           zhonePtpStatusTable 1.3.6.1.4.1.5504.4.17.1.2 no-access
The read-only attributes associated with the 1588 module.
               zhonePtpStatusEntry 1.3.6.1.4.1.5504.4.17.1.2.1 no-access
A row in the zhonePtpStatusTable
                   zhonePtpStatusMacAddress 1.3.6.1.4.1.5504.4.17.1.2.1.1 macaddress read-only
The ptpMacAddr is used to set the PTP ClockIdentifier defined in the PTP standard. It identifies the clock in the PTP network and as such should be unique within the PTP network.
                   zhonePtpConfigTimeSource 1.3.6.1.4.1.5504.4.17.1.2.1.2 integer read-only
Time source for the PTP. Enumeration: 'ntp': 5, 'handSet': 6, 'internalOscillator': 8, 'other': 7, 'radio': 3, 'atom': 1, 'gps': 2, 'ptp': 4.
                   zhonePtpConfigClockStratum 1.3.6.1.4.1.5504.4.17.1.2.1.3 integer read-only
Indicates the stratum level of the local clock. Enumeration: 'stratum3': 5, 'force': 1, 'bestClockStratumThatCanBeSlave': 4, 'stratum4': 6, 'defaultStratum': 7, 'primaryReference': 2, 'secondaryReference': 3.
                   zhonePtpConfigClockAccuracy 1.3.6.1.4.1.5504.4.17.1.2.1.4 integer read-only
Accuracy of this clock. Used in determining best master clock. Enumeration: 'gT10S': 18, 'uSec10': 6, 'uSec2point5': 5, 'nSec25': 1, 'mSec250': 15, 'mSec1': 10, 'mSec10': 12, 'nSec250': 3, 'sec1': 16, 'mSec2point5': 11, 'uSec1': 4, 'uSec250': 9, 'mSec100': 14, 'sec10': 17, 'mSec25': 13, 'accUnknown': 19, 'nSec100': 2, 'uSec100': 8, 'uSec25': 7.
                   zhonePtpStatusTxMode 1.3.6.1.4.1.5504.4.17.1.2.1.5 integer read-only
By default, Semtech sends multicast messages (e.g. Announce Messages) if they are meant for more than one node. Messages destined to a single node are sent as unicast messages. If we want to support Acceptable Master and Slave tables, we need the uniOnly option. Enumeration: 'uniOnly': 2, 'multiOnly': 3, 'standard': 1.
 zhonePtpModule 1.3.6.1.4.1.5504.6.119
Managed data objects for Zhone's 1588 Precision Timing Protocol.
     zhonePtpGroup 1.3.6.1.4.1.5504.9.1.52
Object groups for ptp objects.