Zhone-GPON-MIB: View SNMP OID List / Download MIB

VENDOR: ZHONE TECHNOLOGIES


 Home MIB: Zhone-GPON-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
       zhoneGponObjectID 1.3.6.1.4.1.5504.5.14.1
           zhoneGponOltConfigTable 1.3.6.1.4.1.5504.5.14.1.1 no-access
Configuration parameters that apply to one OLT. This profile is auto-created.
               zhoneGponOltConfigEntry 1.3.6.1.4.1.5504.5.14.1.1.1 no-access
One row of the gpon olt config entry table.
                   zhoneGponOltIfIndex 1.3.6.1.4.1.5504.5.14.1.1.1.1 interfaceindex no-access
The ifIndex of the physical olt interface.
                   zhoneGponOltConfigMaxRtPropagationDelay 1.3.6.1.4.1.5504.5.14.1.1.1.2 integer32 read-write
Maximum round trip propagation delay. Combined with max ONU response time and preassigned delay determins maximum logical PON distance. Default 200 usec for 20 dm.
                   zhoneGponOltConfigMaxOnuResponseTime 1.3.6.1.4.1.5504.5.14.1.1.1.3 integer32 read-write
Combined with max rt propagation delay, determins maximum logical PON distance.
                   zhoneGponOltConfigPreassignedEqD 1.3.6.1.4.1.5504.5.14.1.1.1.4 integer32 read-write
Combined with max rt propagation delay and max onu response time determines max logical PON distance.
                   zhoneGponOltConfigLosAlpha 1.3.6.1.4.1.5504.5.14.1.1.1.5 integer32 read-write
Number of loss-of-signal occurrences to trigger alarm.
                   zhoneGponOltConfigLofAlpha 1.3.6.1.4.1.5504.5.14.1.1.1.6 integer32 read-write
Number of loss-of-frame occurrences to trigger alarm.
                   zhoneGponOltConfigLoamAlpha 1.3.6.1.4.1.5504.5.14.1.1.1.7 integer32 read-write
Number of loss-of-OAM occurrences to trigger alarm.
                   zhoneGponOltConfigScrambler 1.3.6.1.4.1.5504.5.14.1.1.1.8 zhoneenabledflag read-write
Description.
                   zhoneGponOltConfigFecMode 1.3.6.1.4.1.5504.5.14.1.1.1.9 zhoneenabledflag read-write
Enables or disables forward error correction.
                   zhoneGponOltConfigAutoLearn 1.3.6.1.4.1.5504.5.14.1.1.1.10 zhoneenabledflag read-write
Enable or disable password auto-learn mode.
                   zhoneGponOltConfigPowerLevel 1.3.6.1.4.1.5504.5.14.1.1.1.11 unsigned32 read-write
Olt power level. For the Broadlight 3000, values will be rounded down to one of 0, 3, or 6.
                   zhoneGponOltConfigGuardBitCount 1.3.6.1.4.1.5504.5.14.1.1.1.12 integer32 read-write
Number of guard bits for upstream transmission.
                   zhoneGponOltConfigDbaMode 1.3.6.1.4.1.5504.5.14.1.1.1.13 integer read-write
Working DBA mode. Enumeration: 'piggyback': 2, 'predictive': 1, 'wholeReport': 3.
                   zhoneGponOltConfigGemBlockSize 1.3.6.1.4.1.5504.5.14.1.1.1.14 integer32 read-write
Basic unit in bytes used by all ONUs for DBA reports of their queue occupancy (for piggyback and whole-report DBA only).
                   zhoneGponOltConfigUsBerInterval 1.3.6.1.4.1.5504.5.14.1.1.1.15 integer32 read-write
Interval for upstream bit error rate calculation.
                   zhoneGponOltConfigDsBerInterval 1.3.6.1.4.1.5504.5.14.1.1.1.16 integer32 read-write
Interval used for downstream bit error rate calculation.
                   zhoneGponOltConfigBerSfThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.17 integer32 read-write
Threshold is 10**(-N) for signal fail.
                   zhoneGponOltConfigBerSdThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.18 integer32 read-write
Threshold is 10**(-N) for signal degrade. Must exceed sf threshold.
                   zhoneGponOltConfigFecRequest 1.3.6.1.4.1.5504.5.14.1.1.1.19 zhoneenabledflag read-write
Indicates whether OLT turns on FEC indication for all Alloc-Id in the Upstream Bandwidth Map.
                   zhoneGponOltConfigKeyExchange 1.3.6.1.4.1.5504.5.14.1.1.1.20 zhoneenabledflag read-write
Specifies whether Single Key exchange should be performed during ONU activation process.
                   zhoneGponOltConfigMinRtPropagationDelay 1.3.6.1.4.1.5504.5.14.1.1.1.21 integer32 read-write
If closest ONU location is known, GPON_stack uses this value in order to limit the size of the quiet zone.
                   zhoneGponOltConfigMinOnuResponseTime 1.3.6.1.4.1.5504.5.14.1.1.1.22 integer32 read-write
GPON_stack uses this value in order to limit the size of the quiet zone.
                   zhoneGponOltConfigEqDMeasureCycles 1.3.6.1.4.1.5504.5.14.1.1.1.23 integer32 read-write
Defines the number of measurement cycles in the Ranging process.
                   zhoneGponOltConfigDriftControlInterval 1.3.6.1.4.1.5504.5.14.1.1.1.24 integer32 read-write
Defines the interval of periodic monitoring on drifts of upstream data.
                   zhoneGponOltConfigDriftControlLimit 1.3.6.1.4.1.5504.5.14.1.1.1.25 integer32 read-write
Indicates the limit of upstream data drift.
                   zhoneGponOltConfigAllocCycleLength 1.3.6.1.4.1.5504.5.14.1.1.1.26 integer32 read-write
Alloc-ID assignment map cycle length.
                   zhoneGponOltConfigMinUsAlloc 1.3.6.1.4.1.5504.5.14.1.1.1.27 integer32 read-write
Size of minimal upstream allocation per frame.
                   zhoneGponOltConfigAckTimeout 1.3.6.1.4.1.5504.5.14.1.1.1.28 integer32 read-write
Timeout length of Acknowledge message.
                   zhoneGponOltConfigPlsMaxAllocSize 1.3.6.1.4.1.5504.5.14.1.1.1.29 integer32 read-write
Indecates a size of unassigned allocation that should be attached to the end of ranging window.
                   zhoneGponOltConfigDbaCycle 1.3.6.1.4.1.5504.5.14.1.1.1.30 unsigned32 read-write
The Dynamic Bandwidth Allocation(dba) cycle determines the DBA interval size. Its an integer multiplicant of 2 milli seconds. The range of values for the dba cycle can be between 2ms-10ms.
                   zhoneGponOltConfigSrDbaReportingBlockSize 1.3.6.1.4.1.5504.5.14.1.1.1.31 unsigned32 read-write
For DBA of SR type, the block size defines the resolution of the status reports per PON link.The default value is 48 bytes.
                   zhoneGponOltConfigProtectionSwitchoverTimer 1.3.6.1.4.1.5504.5.14.1.1.1.32 unsigned32 read-write
If we receive LOS alarm for a link in Active state, the link state changes to Switch Over Pending state. If the actual switch-over does not happen after this protection-switchover-timeout expires, the link will go back to Active state
                   zhoneGponOltConfigPreambleOverride 1.3.6.1.4.1.5504.5.14.1.1.1.33 zhoneenabledflag read-write
Used to force the OLT to use the Preamble configuration in the OLT configuration profile. Otherwise the Preamble configuration will be determined at runtime and based on the SFP.
                   zhoneGponOltConfigPreambleType0 1.3.6.1.4.1.5504.5.14.1.1.1.34 octet string read-write
Byte number for preamble type 0. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
                   zhoneGponOltConfigPreambleType1 1.3.6.1.4.1.5504.5.14.1.1.1.35 octet string read-write
Byte number for preamble type 1. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
                   zhoneGponOltConfigPreambleType3PreRange 1.3.6.1.4.1.5504.5.14.1.1.1.36 octet string read-write
Byte number for preamble type 3 pre-ranging. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
                   zhoneGponOltConfigPreambleType3PostRange 1.3.6.1.4.1.5504.5.14.1.1.1.37 octet string read-write
Byte number for preamble type 3 post-ranging. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
                   zhoneGponOltConfigPreambleType3Pattern 1.3.6.1.4.1.5504.5.14.1.1.1.38 octet string read-write
Preamble type 3 pattern. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
                   zhoneGponOltConfigBipErrorMonitoring 1.3.6.1.4.1.5504.5.14.1.1.1.39 integer read-write
If in disabled mode, do not report BIP errors, do not disable ONU and do not throw any traps. If in monitorOnly mode, monitor BIP errors and if BIP Error Threshold exceeded, set appropriate zhoneGponOnuStatusWord bits based on the type of BIP errors and throw zhoneGponOnuError trap. If in blockOnError mode, monitor BIP errors and if BIP Error Threshold exceeded, block traffic, disable ONU ranging, set appropriate zhoneGponOnuStatusWord bits based on the type of BIP errors, and throw zhoneGponOnuError and linkDownTrap traps. Enumeration: 'disabled': 1, 'blockOnError': 3, 'monitorOnly': 2.
                   zhoneGponOltConfigBipErrorsPerSampleThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.40 integer32 read-write
If the number of BIP errors per sample exceeds this threshold, it is counted as an errored sample.
                   zhoneGponOltConfigBipErroredSamplesThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.41 integer32 read-write
If the number of errored samples exceed this sample threshold, report and disable the onu if in blockOnError mode, otherwise simply report the threshold as being exceeded.
                   zhoneGponOltConfigBipMaxSampleGap 1.3.6.1.4.1.5504.5.14.1.1.1.42 integer32 read-write
If two adjancent errored samples were taken farther apart than this threshold, do not count the earlier sample as an errored sample.
                   zhoneGponOltConfigRogueOnuDetection 1.3.6.1.4.1.5504.5.14.1.1.1.43 integer read-write
Controls detection of rogue ONU on fiber. Values are: 1. detection disabled 2. detect via measurement from rssi process 3. detect via indication from background process. 4. normally off, but switch to rssi mode if rogue is suspected. Enumeration: 'disabled': 1, 'backgroundProcess': 3, 'autoRssi': 4, 'rogueRssi': 2.
                   zhoneGponOltConfigRogueOnuDetectFrequency 1.3.6.1.4.1.5504.5.14.1.1.1.44 integer32 read-write
Frequency in seconds for detection background task.
                   zhoneGponOltConfigRogueOnuRxPowerThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.45 integer32 read-write
Power level below which to report rssi rogue ONU.
           zhoneGponOltOnuConfigTable 1.3.6.1.4.1.5504.5.14.1.2 no-access
Configuration parameters applying to a single onu stacked on an olt. This profile is auto-created.
               zhoneGponOltOnuConfigEntry 1.3.6.1.4.1.5504.5.14.1.2.1 no-access
A row in the gpon olt-onu config table.
                   zhoneGponOltOnuIfIndex 1.3.6.1.4.1.5504.5.14.1.2.1.1 interfaceindex no-access
IfIndex of the onu interface stacked on the olt.
                   zhoneGponOltOnuConfigSerialNoVendorId 1.3.6.1.4.1.5504.5.14.1.2.1.2 zhoneadminstring read-write
This is a string of 4 ascii characters representing the vendor ID portion of the onu serial number. Example: 'ZNTS' for Zhone.
                   zhoneGponOltOnuConfigSerialNoVendorSpecific 1.3.6.1.4.1.5504.5.14.1.2.1.3 zhoneadminstring read-write
This is a string of ascii decimal digits representing the vendor-specific portion of the onu serial number.
                   zhoneGponOltOnuConfigPassword 1.3.6.1.4.1.5504.5.14.1.2.1.4 zhoneadminstring read-write
Password (10 bytes).
                   zhoneGponOltOnuConfigAutoLearn 1.3.6.1.4.1.5504.5.14.1.2.1.5 zhoneenabledflag read-write
Indicates whether password is auto-learned.
                   zhoneGponOltOnuConfigPowerLevel 1.3.6.1.4.1.5504.5.14.1.2.1.6 integer32 read-write
Olt power level. For the Broadlight 3000, values will be rounded down to one of 0, 3, or 6.
                   zhoneGponOltOnuConfigUsBerInterval 1.3.6.1.4.1.5504.5.14.1.2.1.7 integer32 read-write
Interval for upstream bit error rate calculation.
                   zhoneGponOltOnuConfigDsBerInterval 1.3.6.1.4.1.5504.5.14.1.2.1.8 integer32 read-write
Interval for downstream bit error rate.
                   zhoneGponOltOnuConfigOnuAdded 1.3.6.1.4.1.5504.5.14.1.2.1.9 truthvalue read-write
Indicates to Broadlight that onu is activated. May not be used.
                   zhoneGponOltOnuConfigOmciFileName 1.3.6.1.4.1.5504.5.14.1.2.1.10 zhoneadminstring read-write
Name of OMCI configuration file for this ONT.
                   zhoneGponOltOnuConfigMEProfileName 1.3.6.1.4.1.5504.5.14.1.2.1.11 zhoneadminstring read-write
This is the name of a Profile that contains OMCI commands which can configure an ONU. It is expected that this Profile contain OMCI commands that configure the Managed Entities (ME) on an ONU.
                   zhoneGponOltOnuConfigGenericProfileName 1.3.6.1.4.1.5504.5.14.1.2.1.12 zhoneadminstring read-write
This is the name of a Profile that contains OMCI commands which can configure an ONU. It is expected that this Profile contain generic commands that are common to multiple ONUs.
                   zhoneGponOltOnuConfigPhysicalTraps 1.3.6.1.4.1.5504.5.14.1.2.1.13 zhoneenabledflag read-write
If enabled, then an asynchronous notification from the ONT with ME class ONT-G triggers an omciOnuAlarms trap. The alarm conditions for this ME class are: equipment alarm, powering alarm, battery missing, battery failure, battery low, physical intrusion alarm, and self-test failure.
                   zhoneGponOltOnuConfigOntTraps 1.3.6.1.4.1.5504.5.14.1.2.1.14 zhoneenabledflag read-write
If enabled, then an asynchronous notification from the ONT with ME class other than ONT-G triggers an omciOnuAlarms trap.
                   zhoneGponOltOnuConfigLineStatusTraps 1.3.6.1.4.1.5504.5.14.1.2.1.15 integer read-write
If enabled, then gponOnuLineStatusChange traps, and also LinkUp/LinkDown traps, are sent whenever line status changes between up and down. If disabled, none of these traps is sent. If auto, then line status traps are sent if the 'dying gasp' flag is on (for line down), or if the 'dying gasp' flag was on (for line up). Link down/up traps are not sent. Enumeration: 'disabled': 2, 'auto': 3, 'enabled': 1, 'linkonly': 4.
                   zhoneGponOltOnuConfigAutoUpgrade 1.3.6.1.4.1.5504.5.14.1.2.1.16 zhoneenabledflag read-write
If enabled, then the ONU s/w will be upgraded if the ONU version does not match the assoicated remote upgrade profile. Changing this variable to disabled will not abort a remote software upgrade already in progress.
                   zhoneGponOltOnuConfigSerialNoVendorSpecificFsan 1.3.6.1.4.1.5504.5.14.1.2.1.17 octet string read-write
This is a string of ascii decimal digits representing the vendor-specific portion of the onu serial number in hex format ( FSAN ).
                   zhoneGponOltOnuConfigUseRegId 1.3.6.1.4.1.5504.5.14.1.2.1.18 zhoneenabledflag read-write
If enabled, and if the onu is activated, then when an ONT is discovered with a registration ID that matches this ONU's password field, then the ONU will be auto-assigned to that ONT.
                   zhoneGponOltOnuConfigModel 1.3.6.1.4.1.5504.5.14.1.2.1.19 octet string read-only
Model ID returned from this Onu.
                   zhoneGponOltOnuConfigOntVersion 1.3.6.1.4.1.5504.5.14.1.2.1.20 octet string read-only
This object defines the version of the ONT as defined by the vendor. The character value '0' indicates that the version information is not available or applicable.
                   zhoneGponOltOnuConfigImageVersionActive 1.3.6.1.4.1.5504.5.14.1.2.1.21 octet string read-only
Version information for the active s/w image.
                   zhoneGponOltOnuConfigImageVersionStandby 1.3.6.1.4.1.5504.5.14.1.2.1.22 octet string read-only
Version information for the standby s/w image.
                   zhoneGponOltOnuConfigUsRxPowerMonitoring 1.3.6.1.4.1.5504.5.14.1.2.1.23 integer read-write
If in disabled mode, do not report Upstream Onu Rx Power errors, do not disable ONU and do not throw any traps. If in monitorOnly mode, monitor Upstream Onu Rx Power levels and if level is outside of thresholds, set appropriate zhoneGponOnuStatusWord bits and throw zhoneGponOnuError trap. If in blockOnError mode, monitor Upstream Onu Rx Power levels and if level is outside of thresholds, block traffic, disable ONU ranging, set appropriate zhoneGponOnuStatusWord bits and throw both zhoneGponOnuError and linkDownTrap traps. Enumeration: 'disabled': 1, 'blockOnError': 3, 'monitorOnly': 2.
                   zhoneGponOltOnuConfigUsRxPowerHighThreshold 1.3.6.1.4.1.5504.5.14.1.2.1.24 integer32 read-write
Upstream Receive Power High Threshold value.
                   zhoneGponOltOnuConfigUsRxPowerLowThreshold 1.3.6.1.4.1.5504.5.14.1.2.1.25 integer32 read-write
Upstream Receive Power Low Threshold value.
                   zhoneGponOltOnuConfigDbaStatusReporting 1.3.6.1.4.1.5504.5.14.1.2.1.26 zhoneenabledflag read-write
There are two types of DBA, Status Reporting and Non Status Reporting. The value is enabled or disabled. The default is disabled.
                   zhoneGponOltOnuConfigOmciDataSync 1.3.6.1.4.1.5504.5.14.1.2.1.27 unsigned32 read-only
If the MIB data sync value returned from the ONU on a MIB audit matches the MXK value, config not required.
                   zhoneGponOltOnuConfigSnmpDataSync 1.3.6.1.4.1.5504.5.14.1.2.1.28 unsigned32 read-only
If the SNMP provisioning change value returned from the CPE matches the MXK value, config not required.
                   zhoneGponOltOnuConfigNextAvailableGemPort 1.3.6.1.4.1.5504.5.14.1.2.1.29 integer32 read-only
Next available GEM PORT for the ONU.
                   zhoneGponOltOnuConfigAutoConfigState 1.3.6.1.4.1.5504.5.14.1.2.1.30 integer read-only
Track whether the ONU has been auto-configured. Enumeration: 'disabled': 3, 'init': 1, 'done': 2, 'error': 4.
                   zhoneGponOltOnuConfigLinkStatusAlarmSeverity 1.3.6.1.4.1.5504.5.14.1.2.1.31 integer read-write
Based on the severity set in this field LinkUp/LinkDown alarms are raised. Enumeration: 'major': 2, 'critical': 1, 'minor': 3.
           zhoneGponPortConfigTable 1.3.6.1.4.1.5504.5.14.1.3 no-access
The gpon port is similiar to VCLs in ATM. Data is transferred between OLT and ONU via ports. This profile is dynamically created during CLI bridge-add, host-add, interface-add commands but must be explicitly created during SNMP operation. GEM ports can be created using a supplied I/F index value or using the next available I/F index value. Since the GEM Port is a virtual device, ZMS prefers to supply the I/F index value because ZMS cannot lookup the newly created GEM port using shelf/slot/olt/port indexing ( virual devices do not support these values). How to create a GEM port using next available I/F Index value, using a single SNMP packet with multiple var-binds: 1. Do an SNMP-Next of the object ifIndexNext to determine the I/F index value of the new GEM port. The SNMP-Next will not result in the auto-increment of ifIndexNext. 2. Issue single SNMP set command containing the following: zhoneGponPortConfigRowStatus.1 = create zhoneGponPortConfigRowShelf.1 = 1 zhoneGponPortConfigRowSlot.1 = GEM port slot zhoneGponPortConfigRowOlt.1 = GEM port OLT zhoneGponPortConfigRowPort.1 = GEM Port ID value zhoneGponPortConfigRowTrafficProfile.1 = traffic profile The GEM port will be created using the next available ifIndex. How to create a GEM port with a specified I/F index value, using a single SNMP packet with multiple var-binds: 1. Do an SNMP-Get of the object ifIndexNext to determine the next available I/F index value. The SNMP-Get will result in the auto-increment of ifIndexNext. 2. Issue single SNMP set command containing the following: zhoneGponPortConfigRowStatus.aaa = create zhoneGponPortConfigRowShelf.aaa = 1 zhoneGponPortConfigRowSlot.aaa = GEM port slot zhoneGponPortConfigRowOlt.aaa = GEM port OLT zhoneGponPortConfigRowPort.aaa = GEM Port ID value zhoneGponPortConfigRowTrafficProfile.aaa = traffic profile where aaa is the I/F index value collected in step 1. A GEM Port cannot be created if an I/F translate record already exists using the supplied I/F index value. How to delete a GEM port using a single SNMP packet: 1. Determine I/F index of GEM port config profile (aaa) 2. Issue single SNMP set command containing the following: zhoneGponPortConfigRowStatus.aaa = destroy Special Notes: 1. The deletion of a GEM port will be prevented if the GEM port supports bridges, interfaces, etc. 2. The GEM port ID value determines the GEM port ONU.
               zhoneGponPortConfigEntry 1.3.6.1.4.1.5504.5.14.1.3.1 no-access
A row in the gpon port config table.
                   zhoneGponPortIfIndex 1.3.6.1.4.1.5504.5.14.1.3.1.1 interfaceindex no-access
The ifIndex of the gpon-port interface stacked on the olt.
                   zhoneGponPortConfigRowStatus 1.3.6.1.4.1.5504.5.14.1.3.1.2 zhonerowstatus read-only
The row status for the port config table.
                   zhoneGponPortConfigMulticast 1.3.6.1.4.1.5504.5.14.1.3.1.3 truthvalue read-only
Specifies whether this is a multicast or unicast port. If unicast, only one onu may be given, and the unicast-onu-id field is used. If multicast is true, then the multicast-onu-ids is used to name the onus.
                   zhoneGponPortConfigEncrypted 1.3.6.1.4.1.5504.5.14.1.3.1.4 truthvalue read-only
Specifies whether port-id PLOAM messages are encrypted. Must be false if multicast.
                   zhoneGponPortConfigDirection 1.3.6.1.4.1.5504.5.14.1.3.1.5 integer read-only
Direction of data for this port. Enumeration: 'down': 1, 'bidirectional': 3, 'up': 2.
                   zhoneGponPortConfigTrafficProfile 1.3.6.1.4.1.5504.5.14.1.3.1.6 unsigned32 read-only
Index of GEM Port traffic profile for this port. A zero value indicates no GEM Port traffic profile has been selected.
                   zhoneGponPortConfigRowShelf 1.3.6.1.4.1.5504.5.14.1.3.1.7 unsigned32 read-only
This is a WRITE-ONLY variable used during port create/delete operations.
                   zhoneGponPortConfigRowSlot 1.3.6.1.4.1.5504.5.14.1.3.1.8 unsigned32 read-only
This is a WRITE-ONLY variable used during port create/delete operations.
                   zhoneGponPortConfigRowOlt 1.3.6.1.4.1.5504.5.14.1.3.1.9 unsigned32 read-only
This is a WRITE-ONLY variable used during port create/delete operations.
                   zhoneGponPortConfigRowPort 1.3.6.1.4.1.5504.5.14.1.3.1.10 unsigned32 read-only
This is a WRITE-ONLY variable used during port create/delete operations.
                   zhoneGponPortConfigRowTrafficProfile 1.3.6.1.4.1.5504.5.14.1.3.1.11 unsigned32 read-only
This is a WRITE-ONLY variable used during port create/delete operations.
                   zhoneGponPortConfigRowOnuId 1.3.6.1.4.1.5504.5.14.1.3.1.12 unsigned32 read-only
The subPort of the ONU on which this GEM port is to be stacked. This is a write-only variable during row create.
                   zhoneGponPortConfigTrafficManagementProfileIndex 1.3.6.1.4.1.5504.5.14.1.3.1.13 unsigned32 read-only
This object points to the associated Traffic Management profile. If there is no traffic control for the GEM port, set it to 0.
           zhoneGponAllocIdTable 1.3.6.1.4.1.5504.5.14.1.4 no-access
Table for management of upstream bandwidth
               zhoneGponAllocIdEntry 1.3.6.1.4.1.5504.5.14.1.4.1 no-access
Entry in the gpon allocId table.
                   zhoneGponAllocIdIndex 1.3.6.1.4.1.5504.5.14.1.4.1.1 integer32 no-access
An Id number which must be unique for a given OLT.
                   zhoneGponAllocIdRowStatus 1.3.6.1.4.1.5504.5.14.1.4.1.2 zhonerowstatus read-only
Row status for the gpon alloc-id table.
                   zhoneGponAllocIdOnuId 1.3.6.1.4.1.5504.5.14.1.4.1.3 integer32 read-only
The onu number for this olt to which we are allocating bandwidth. Cannot be greater than number of onus for the olt. This field cannot be changed once the alloc-id has been created.
                   zhoneGponAllocIdGuaranteedBw 1.3.6.1.4.1.5504.5.14.1.4.1.4 integer32 read-only
Bandwidth guaranteed by this alloc-id. This value is specified in kilobits per second. Only multiples of 512 are allowed, and the value may not exceed 2621440 (i.e. 2.5 gigabits per second).
                   zhoneGponAllocIdTrafficClass 1.3.6.1.4.1.5504.5.14.1.4.1.5 integer read-only
Whether traffic is Constant Bit Rate or Unspecified Bit Rate. Enumeration: 'cbr': 1, 'ubr': 2.
                   zhoneGponAllocIdCompensated 1.3.6.1.4.1.5504.5.14.1.4.1.6 truthvalue read-only
For CBR, indicates whether compensated.
           zhoneGponSerialNoTable 1.3.6.1.4.1.5504.5.14.1.5 no-access
Table of discovered serial numbers available for assignment to onus.
               zhoneGponSerialNoEntry 1.3.6.1.4.1.5504.5.14.1.5.1 no-access
Row in the Gpon onu serial number table
                   zhoneGponSerialNoOltLgIfIndex 1.3.6.1.4.1.5504.5.14.1.5.1.1 interfaceindex no-access
Linegroup ifIndex of the Olt on which serial number was discovered.
                   zhoneGponSerialNoIndexId 1.3.6.1.4.1.5504.5.14.1.5.1.2 unsigned32 no-access
An identifying number, unique within olt, for this discovered onu serial number.
                   zhoneGponSerialNoVendorId 1.3.6.1.4.1.5504.5.14.1.5.1.3 zhoneadminstring read-only
The 4-character vendor id portion of serial number.
                   zhoneGponSerialNoVendorSpecific 1.3.6.1.4.1.5504.5.14.1.5.1.4 zhoneadminstring read-write
Vendor specific portion of the unassigned onu serial number, a string of decimal digits.
                   zhoneGponSerialNoTimeStamp 1.3.6.1.4.1.5504.5.14.1.5.1.5 octet string read-only
Time, as ascii string, that the serial number was discovered.
           zhoneGponTrapPrefix 1.3.6.1.4.1.5504.5.14.1.6
Place-holder object for gpon traps, which must have a final digit of 0 in OID.
               zhoneGponTraps 1.3.6.1.4.1.5504.5.14.1.6.0
Traps raised by Gpon Rp.
                   zhoneGponSerialNumberFound 1.3.6.1.4.1.5504.5.14.1.6.0.1
Notification that an ONU serial number has been discovered.
                   zhoneGponSerialNumberLost 1.3.6.1.4.1.5504.5.14.1.6.0.2
Notification that a previously discovered ONU serial number is no longer available.
                   zhoneGponOnuLineStatusChange 1.3.6.1.4.1.5504.5.14.1.6.0.3
Description.
                   zhoneGponOmciOnuAlarmsTrap 1.3.6.1.4.1.5504.5.14.1.6.0.4
Current active alarms for an ONU entity. Alarms contained in the trap bindings will be for only one specific entity. If an entity alarm is not contained in the trap bindings then the alarm is either not active, not enabled, or not supported. If there are no alarms for the entity, then there will only be one alarm in the trap bindings and that alarm will have a value of zero and the alarm string will be 'None'.
                   zhoneGponOmciOnuDownloadStatusChange 1.3.6.1.4.1.5504.5.14.1.6.0.5
Trap will be raised for Image Download status changes.
                   zhoneGponOltOpticsAlarmsTrap 1.3.6.1.4.1.5504.5.14.1.6.0.6
Raised when SFP reports optics alarms condition for an SFP.
                   zhoneGponOnuError 1.3.6.1.4.1.5504.5.14.1.6.0.7
One of the ONU error conditions is present for the specified ONU. Report zhoneGponOnuStatusWord to indicate which error has occurred.
                   zhoneGponRogueOnuTrap 1.3.6.1.4.1.5504.5.14.1.6.0.8
A rogue ONU has been detected on this OLT by the background process
                   zhoneGponRssiRogueOnuTrap 1.3.6.1.4.1.5504.5.14.1.6.0.9
Rogue ONU has been detected by RSSI process on this OLT.
                   zhoneGponOltStatusWordTrap 1.3.6.1.4.1.5504.5.14.1.6.0.10
Change in one of the gpol olt status word bits has been detected.
                   zhoneGponOnuAutoAssign 1.3.6.1.4.1.5504.5.14.1.6.0.11
Notification that an ONU ID has been auto assigned.
           zhoneGponOnuStatusTable 1.3.6.1.4.1.5504.5.14.1.7 no-access
Current status of onu as reported from Gpon driver.
               zhoneGponOnuStatusEntry 1.3.6.1.4.1.5504.5.14.1.7.1 no-access
Row in the zhoneGponOnuStatusTable.
                   zhoneGponOnuStatusWord 1.3.6.1.4.1.5504.5.14.1.7.1.1 bits read-only
Bit-encoded current onu status from gpon driver Bits: 'messageError': 14, 'signalDegrade': 6, 'startUpFailure': 10, 'lossOfSignal': 2, 'noAlarm': 0, 'inactive': 1, 'excessiveBipErrorsOnuDisabled': 18, 'physEquipError': 15, 'remoteDefect': 8, 'driftOfWindow': 4, 'signalFail': 5, 'usRxPowerErrorOnuNotDisabled': 21, 'excessiveBipErrorsOnuNotDisabled': 19, 'lossOfFrame': 3, 'bit17notUsed': 17, 'lossOfGemChanDelin': 7, 'transmitterFailure': 9, 'rogueOn': 22, 'lossOfAck': 11, 'dyingGasp': 12, 'manualOnuRebooted': 23, 'usRxPowerErrorOnuDisabled': 20, 'bit16notUsed': 16, 'lossOfPloamSync': 13.
                   zhoneGponOnuOmciState 1.3.6.1.4.1.5504.5.14.1.7.1.2 integer read-only
Current configuration status for ONU. 1. queued for configuration (waiting) 2. transitional state before configuration (pending) 3. in process of configuration (config) 4. unspecified error (error) 5. configuration successful (done) 6. image download in progress (download) 7. image download aborted (aborted) 8. state cannot be determined (unknown) 9. ONU is down (down) 10. no configuration has been attempted (noConfig) 11. ONU unreachable for RG configuration (rgComError) 12. Some RG commands failed, may impact service (rgServiceSetupErr) 13. OMCI configuration failed (omciFailed) 14. OMCI failed and also ONU unreachable for RG (omciErrAndRgComErr) 15. OMCI failed and also RG commands failed (omciErrAndRgServErr) 16. Some post-config commands failed (postCfgError) 17. OMCI failed and also some post-config commands failed (omciErrAndPostCfgErr) Enumeration: 'omciErrAndPostCfgErr': 17, 'rgComError': 11, 'unknown': 8, 'noConfig': 10, 'omciErrAndRgComErr': 14, 'down': 9, 'waiting': 1, 'rgServiceSetupErr': 12, 'done': 5, 'postCfgError': 16, 'aborted': 7, 'error': 4, 'download': 6, 'omciErrAndRgServErr': 15, 'config': 3, 'omciFailed': 13, 'pending': 2.
                   zhoneGponOnuOpticRssi 1.3.6.1.4.1.5504.5.14.1.7.1.3 integer32 read-only
RSSI power of the SFP per ONU. The value is in tenths of dB.
                   zhoneGponOntRxPower 1.3.6.1.4.1.5504.5.14.1.7.1.4 integer32 read-only
Rx Power as reported by the ONT. The value is in tenths of dB.
                   zhoneGponOntVersion 1.3.6.1.4.1.5504.5.14.1.7.1.5 octet string read-only
This object defines the version of the ONT as defined by the vendor. The character value '0' indicates that the version information is not available or applicable.
                   zhoneGponOnuDistance 1.3.6.1.4.1.5504.5.14.1.7.1.6 unsigned32 read-only
Distance from Olt to Ont in meters, as computed from Eqd.
           zhoneOnuOmciMEProfileTable 1.3.6.1.4.1.5504.5.14.1.8 no-access
Table containing the OMCI commands for the Managed Entities (ME) on an ONU. The following 'how to' examples demonstrate access of the object zhoneOnuOmciMEOmciCommands. How to create ME profile: 1. Determine ME profile instance 2. Place file into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = create zhoneOnuOmciMEProfileName.aaa = ME profile name zhoneOnuOmciMEProfileFilename.aaa = How to update existing ME profile from a file: 1. Determine ME profile instance 2. Place file into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = import zhoneOnuOmciMEProfileName.aaa = ME profile name zhoneOnuOmciMEProfileFilename.aaa = How to extract ME profile into a file: 1. Determine ME profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = export zhoneOnuOmciMEProfileFilename.aaa = 3. The file now exists on uplink file system How to delete ME profile: 1. Determine ME profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = destroy
               zhoneOnuOmciMEProfileEntry 1.3.6.1.4.1.5504.5.14.1.8.1 no-access
Row in the ME Profile table.
                   zhoneOnuOmciMEProfileIndex 1.3.6.1.4.1.5504.5.14.1.8.1.1 unsigned32 no-access
A unique index for each row entry (1..n).
                   zhoneOnuOmciMEProfileRowStatus 1.3.6.1.4.1.5504.5.14.1.8.1.2 integer read-only
Row status for the Me profile entry. Not really used for the configuration on the ONUs Enumeration: 'create': 2, 'revert': 7, 'export': 4, 'import': 5, 'active': 1, 'destroy': 3, 'append': 6.
                   zhoneOnuOmciMEProfileName 1.3.6.1.4.1.5504.5.14.1.8.1.3 octet string read-only
Name given to each row entry in the ME Profile table. The name must contain ascii printable characters and cannot contain blanks or forward-slash characters. The name must be null-terminated and the null character is included in the object data length. The name must be unique in the ME profiles.
                   zhoneOnuOmciMEProfileOmciCommands 1.3.6.1.4.1.5504.5.14.1.8.1.4 octet string read-only
Contains the set of OMCI commands and the variable substitutions used in configuring the ONUs. This object will go through some character substitution before being inserted into the database so the maximum string size will not be available. Available string size will vary based on string contents but expect about 10 percent loss. This object cannot be accessed directly. See the comments section for zhoneOnuCmciMEProfileTable on how to acces this object.
                   zhoneOnuOmciMEProfileFileName 1.3.6.1.4.1.5504.5.14.1.8.1.5 octet string read-only
Name of file to be loaded into profile. This object is write-only and is not preserved.
           zhoneOnuOmciGenericProfileTable 1.3.6.1.4.1.5504.5.14.1.9 no-access
Table containing Generic OMCI commands for an ONU. The Generic profile is 'created' from an existing ME profile. During this operation, the 'variable' defintions from the ME profile are extracted from the ME profile and placed into the Generic profile. The Generic profile is 'updated' from a file placed into the uplink's file system. The following 'how to' examples demonstrate access of the object zhoneOnuOmciGenericOmciCommands. How to create Generic profile from ME profile: 1. Determine Generic profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = create zhoneOnuOmciGenericProfileName.aaa = profile name zhoneOnuOmciGenericProfileMESrcProfileName = ME profile source 3. Profile is now created and the profile will not contain any variables and values. How to update existing Generic profile from a file: 1. Determine Generic profile instance 2. Place file into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = import zhoneOnuOmciGenericProfileFileName.aaa = How to extract Generic profile into a file: 1. Determine ME profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = export zhoneOnuOmciGenericProfileFilename.aaa = 3. The file now exists on uplink file system How to delete Generic profile: 1. Determine Generic profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = destroy
               zhoneOnuOmciGenericProfileEntry 1.3.6.1.4.1.5504.5.14.1.9.1 no-access
Row in the OMCI Generic Profile table
                   zhoneOnuOmciGenericProfileIndex 1.3.6.1.4.1.5504.5.14.1.9.1.1 unsigned32 no-access
A unique index for each row entry ( 1..n ).
                   zhoneOnuOmciGenericProfileRowStatus 1.3.6.1.4.1.5504.5.14.1.9.1.2 integer read-only
Row status for the Generic profile entry. Not really used for the configuration of the ONUs Enumeration: 'active': 1, 'destroy': 3, 'create': 2, 'export': 4, 'import': 5.
                   zhoneOnuOmciGenericProfileName 1.3.6.1.4.1.5504.5.14.1.9.1.3 octet string read-only
Name given to each row entry in the Generic Profile table. The name must contain ascii printable characters and cannot contain blanks or forward-slash characters. The name must be null-terminated and the null character is included in the object data length. The name must be unique in the Generic profiles.
                   zhoneOnuOmciGenericProfileOmciCommands 1.3.6.1.4.1.5504.5.14.1.9.1.4 octet string read-only
Contains the generic set of OMCI commands and the variable substitutions used in configuring the ONUs. This object will go through some character substitution before being inserted into the database so the maximum string size will not be available. Available string size will vary based on string contents but expect about 10 percent loss.
                   zhoneOnuOmciGenericProfileMESrcProfileName 1.3.6.1.4.1.5504.5.14.1.9.1.5 octet string read-only
Name of ME profile used to create the Generic profile. The value for this object is only initialized when the profile is created.
                   zhoneOnuOmciGenericProfileFileName 1.3.6.1.4.1.5504.5.14.1.9.1.6 octet string read-only
Name of file to be loaded into profile. This object is write-only and is not preserved.
           zhoneOnuOmciSpecificProfileTable 1.3.6.1.4.1.5504.5.14.1.10 no-access
Table containing Specific OMCI commands for an ONU. The Specific profile is 'created' from existing ME and Generic profiles. During this operation, the 'variable' defintions from the ME and Generic profile are extracted from the profiles and placed into the Specific profile. The ME and Generic profile names are extracted from the ONU's Olt/Onu config profile. The Specific profile is 'updated' from a file placed into the uplink's file system. The following 'how to' examples demonstrate access of the object zhoneOnuOmciSpecificOmciCommands. How to create Specific profile from ME and Generic profiles: 1. Determine Specific profile instance (from ONU's ifIndex) 2. Issue single SNMP set command containing the following: zhoneOnuOmciSpecificProfileRowStatus.aaa = create zhoneOnuOmciSpecificProfileFileName = 3. The profile is now created and the omciCommands contents have been placed into . The name of the ME profile used to create the Speofic profile is installed into zhoneOnuOmciSpecificProfileMESrcProfile. How to update existing Specific profile from a file: 1. Determine Specific profile instance (from ONU's ifIndex) 2. Place file into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = import zhoneOnuOmciGenericProfileFileName.aaa = How to extract Specific profile into a file: 1. Determine Specific profile instance (from ONU's ifIndex) 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = export zhoneOnuOmciGenericProfileFilename.aaa = 3. The file now exists on uplink file system How to delete Specific profile: 1. Determine Specific profile instance (from ONU's ifIndex) 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = destroy
                 zhoneOnuOmciSpecificProfileEntry 1.3.6.1.4.1.5504.5.14.1.10.1 no-access
Row in the OMCI Specific Profile table
                     zhoneOnuOmciSpecificProfileIndex 1.3.6.1.4.1.5504.5.14.1.10.1.1 interfaceindex no-access
A unique index for each row entry. The index value corresponds to the ifIndex of the ONU which uses this profile.
                     zhoneOnuOmciSpecificProfileRowStatus 1.3.6.1.4.1.5504.5.14.1.10.1.2 integer read-only
Row status for the Specific Profile entry. Not really used for the configuration of the ONUs Enumeration: 'active': 1, 'destroy': 3, 'create': 2, 'export': 4, 'import': 5.
                     zhoneOnuOmciSpecificProfileOmciCommands 1.3.6.1.4.1.5504.5.14.1.10.1.3 octet string read-only
Contains the Specific set of OMCI commands and the variable substitutions used in configuring the ONUs. This object will go through some character substitution before being inserted into the database so the maximum string size will not be available. Available string size will vary based on string contents but expect about 10 percent loss.
                     zhoneOnuOmciSpecificProfileMESrcProfileName 1.3.6.1.4.1.5504.5.14.1.10.1.4 octet string read-only
Name of ME profile used to create the Specific profile. The value for this object is only initialized when the profile is created.
                     zhoneOnuOmciSpecificProfileFileName 1.3.6.1.4.1.5504.5.14.1.10.1.5 octet string read-only
Name of file to be loaded into profile. This object is write-only and is not preserved.
           zhoneGponOmciOnuAlarmsTable 1.3.6.1.4.1.5504.5.14.1.11 no-access
A table of all GPON OMCI ONU alarms.
                 zhoneGponOmciOnuAlarmsEntry 1.3.6.1.4.1.5504.5.14.1.11.1 no-access
An entry for each ONU in the zhoneGponOmciOnuAlarmsTable.
                     zhoneGponOmciOnuAlarmsText 1.3.6.1.4.1.5504.5.14.1.11.1.1 octet string read-only
This is a long ascii string which contains the GPON OMCI ONU alarms. Each line of text in this string has the following format: aaa,bbb,ccc,'aaaStr,'bbbStr',d\n where aaa : ME classId ( numeric decimal value ) bbb : alarm index ( numeric decimal value ) ccc : entityId ( numeric decimal value ) aaaStr : string version of ME name bbbStr : string version of alarm name d : alarm severity ( 1=critical, 2=major, 3=minor, 4=warning ) The ME classId is the standard value from the 'Managed entity identifiers' table of G984.4. The alarm index is the zero-based index (G984.4 or G983.2) within the ME class. the entityId is the physical port number on the ONT. Here is a sample: 11,0,513,'PptpEthUni','LanLos',2\n 256,1,0,'OntG','PoweringAlarm',3\n If this string has zero length then there are no active alarms. If this string has a single entry with a classId of 65535 then the alarm collection failed. WARNING! In this description, replace the sinqle quote characters with double quote characters! The Zhone scripts have problems with double quote characters!
           zhoneGponTrafficProfileTable 1.3.6.1.4.1.5504.5.14.1.12 no-access
A table of the GPON GEM Port Traffic profiles.
                 zhoneGponTrafficProfileEntry 1.3.6.1.4.1.5504.5.14.1.12.1 no-access
Row in the zhoneGponPortTrafProfileTable.
                     zhoneGponTrafficProfileIndex 1.3.6.1.4.1.5504.5.14.1.12.1.1 unsigned32 no-access
Used to index an entry in the GEM port traffic profile table
                     zhoneGponTrafficProfileRowStatus 1.3.6.1.4.1.5504.5.14.1.12.1.2 zhonerowstatus read-only
The row status for the GEM Port Traffic profile.
                     zhoneGponTrafficProfileGuaranteedUpstreamBw 1.3.6.1.4.1.5504.5.14.1.12.1.3 integer32 read-only
Bandwidth guaranteed by this alloc-id. This value is specified in kilobits per second. Only multiples of 512 are allowed, and the value may not exceed 2621440 (i.e. 2.5 gigabits per second).
                     zhoneGponTrafficProfileClass 1.3.6.1.4.1.5504.5.14.1.12.1.4 integer read-only
Whether traffic is Constant Bit Rate or Unspecified Bit Rate. Enumeration: 'cbr': 1, 'ubr': 2.
                     zhoneGponTrafficProfileCompensated 1.3.6.1.4.1.5504.5.14.1.12.1.5 truthvalue read-only
For CBR, indicates whether compensated.
                     zhoneGponTrafficProfileShared 1.3.6.1.4.1.5504.5.14.1.12.1.6 truthvalue read-only
TRUE if the GEM Port which uses this traffic descriptor shares and allocation ID with another GEM port. FALSE otherwise. When used more than once in the same ONU, the GEM ports are assigned the same alloc-id value.
                     zhoneGponTrafficProfileDbaEnabled 1.3.6.1.4.1.5504.5.14.1.12.1.7 truthvalue read-only
A flag to indicate if dynamic or static bandwidth allocation is used. The default value of DbaEnabled is false.
                     zhoneGponTrafficProfileDbaFixedUsUbrBw 1.3.6.1.4.1.5504.5.14.1.12.1.8 unsigned32 read-only
Fixed UBR bandwidth will be always allocated UBR bandwidth. The min values of Fixed Ubr bandwidth can be 0 or 128kilo bits per second.Only multiples of 64 kilobits per second are allowed.
                     zhoneGponTrafficProfileDbaFixedUsCbrBw 1.3.6.1.4.1.5504.5.14.1.12.1.9 unsigned32 read-only
Fixed CBR bandwidth will be always allocated CBR bandwidth. The min value of Fixed Cbr bandwidth can be 0 or 512 kilobits per second.Only multiples of 64 kilo bits per second are allowed.
                     zhoneGponTrafficProfileDbaAssuredUsBw 1.3.6.1.4.1.5504.5.14.1.12.1.10 unsigned32 read-only
DBA Assured bandwidth will be allocated when traffic demand exists. The min value of Assured bandwidth can be 0 or 256 kilobits per second. Only multiples of 64 kilo bits per second are allowed.
                     zhoneGponTrafficProfileMaxUsBw 1.3.6.1.4.1.5504.5.14.1.12.1.11 unsigned32 read-only
The Max Bandwidth value should be larger or equal to the sum of Fixed UBR, Fixed CBR and Assured.The increments should be done in the order of 64 kilobits per second.The default value of maximum bandwidth is 0.
                     zhoneGponTrafficProfileExtraUsBwType 1.3.6.1.4.1.5504.5.14.1.12.1.12 integer read-only
Extra Bandwidth = MaxBw - (Assured+FixedUbr+FixedCbr) The two Extra bandwidth types supported are : 1.nonassured 2.besteffort By default the value is nonassured.Nonassured has higher priority for getting unused bandwidth than besteffort. Enumeration: 'nonassured': 1, 'besteffort': 2.
           zhoneGponPortStatusTable 1.3.6.1.4.1.5504.5.14.1.13 no-access
Current status of GEM port as reported from Gpon driver.
                 zhoneGponPortStatusEntry 1.3.6.1.4.1.5504.5.14.1.13.1 no-access
Row in the zhoneGponPortStatusTable.
                     zhoneGponPortStatusAllocId 1.3.6.1.4.1.5504.5.14.1.13.1.1 unsigned32 read-only
The current dynamic alloc-id value for the GEM port.
                     zhoneGponPortStatusDbaStatus 1.3.6.1.4.1.5504.5.14.1.13.1.2 integer read-only
The current DBA status for this GEM port. DBA status reporting is on a per-ONU basis. All GEM ports on the ONU will report the same value. Possible values: sr - DBA type is SR and there is no error nsr - DBA type is NSR and there is no error nsrError - DBA type is NSR and there is an error or the ONU does not support NSR notEnabled - DBA has been disabled notAvailable - cannot communicate with ONU notAdded - ONU is not added to the OLT error - internal error prevents data collection Enumeration: 'notEnabled': 4, 'sr': 1, 'notAdded': 6, 'error': 7, 'notAvailable': 5, 'nsrError': 3, 'nsr': 2.
           zhoneGponOmciStatsCurrentTable 1.3.6.1.4.1.5504.5.14.1.14 no-access
Table of current-interval statistics gathered via OMCI from ONT's as specified in the ME profiles used by that ONT.
                 zhoneGponOmciStatsCurrentEntry 1.3.6.1.4.1.5504.5.14.1.14.1 no-access
Row in zhoneGponOmciStatsCurrentTable. Each row retrieves counters for the current 15-minute interval for one managed entity on one logical port of one ONT.
                     zhoneGponOmciStatsCurrentMEId 1.3.6.1.4.1.5504.5.14.1.14.1.1 unsigned32 no-access
This is the ID of the managed entity in the ITU G984.4 standard for the OMCI statistics we want to read.
                     zhoneGponOmciStatsCurrentLogicalPort 1.3.6.1.4.1.5504.5.14.1.14.1.2 unsigned32 no-access
This specifies which entity on the ONT we want the statistics for. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
                     zhoneGponOmciStatsCurrentText 1.3.6.1.4.1.5504.5.14.1.14.1.3 octet string read-only
Blob of statistics information returned. Format is: PhysPort,I1,A1,I2,A2,...In,An where PhysPort - physical port ID value Ii = attribute index (0-15, ascii-coded decimal integer) within ME according to G984,4 standard. Ai = attribute value (counter, ascii-coded decimal integer) n = number of attributes returned = number requested. Maximum number of attributes per ME is 16.
           zhoneGponOmciStatsPreviousTable 1.3.6.1.4.1.5504.5.14.1.15 no-access
Table of previous-interval statistics gathered via OMCI from ONT's as specified in the ME profiles used by that ONT.
                 zhoneGponOmciStatsPreviousEntry 1.3.6.1.4.1.5504.5.14.1.15.1 no-access
Row in zhoneGponOmciStatsPreviousTable. Each row retrieves counters for the last completed 15-minute interval for one managed entity on one logical port of one ONT.
                     zhoneGponOmciStatsPreviousMEId 1.3.6.1.4.1.5504.5.14.1.15.1.1 unsigned32 no-access
This is the ID of the managed entity in the ITU G984.4 standard for the OMCI statistics we want to read.
                     zhoneGponOmciStatsPreviousLogicalPort 1.3.6.1.4.1.5504.5.14.1.15.1.2 unsigned32 no-access
This specifies which entity on the ONT we want the statistics for. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
                     zhoneGponOmciStatsPreviousText 1.3.6.1.4.1.5504.5.14.1.15.1.3 octet string read-only
Blob of statistics information returned. Format is: PhysPort,I1,A1,I2,A2,...In,An where PhysPort - physical port ID value Ii = attribute index (0-15, ascii-coded decimal integer) within ME according to G984,4 standard. Ai = attribute value (counter, ascii-coded decimal integer) n = number of attributes returned = number requested. Maximum number of attributes per ME is 16.
           zhoneGponOmciStatusTable 1.3.6.1.4.1.5504.5.14.1.16 no-access
Table of current-interval statistics gathered via OMCI from ONT's as specified in the ME profiles used by that ONT.
                 zhoneGponOmciStatusEntry 1.3.6.1.4.1.5504.5.14.1.16.1 no-access
Row in zhoneGponOmciStatsCurrentTable. Each row retrieves counters for the current 15-minute interval for one managed entity on one logical port of one ONT.
                     zhoneGponOmciStatusMEId 1.3.6.1.4.1.5504.5.14.1.16.1.1 unsigned32 no-access
This is the ID of the managed entity in the ITU G984.4 standard for the OMCI statistics we want to read.
                     zhoneGponOmciStatusLogicalPort 1.3.6.1.4.1.5504.5.14.1.16.1.2 unsigned32 no-access
This specifies which entity on the ONT we want the statistics for. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
                     zhoneGponOmciStatusText 1.3.6.1.4.1.5504.5.14.1.16.1.3 octet string read-only
Blob of status information returned. Format is: PhysPort,attrId1,attrName1,attrNumValue1,attrStrValue1... attrIdn,attrNamen,attrNumValuen,attrStrValuen where PhysPort - physical port ID value attrIdn = index number (0-15) of the attribute within the the ME (ascii decimal) attrNamen = name of the attribute (returned by OCS) attrNumValuen = value of the attribute (ascii decimal) attrStrValuen = interpreted value ( 'up', 'down', etc ) n = number of attributes returned = number requested. Maximum number of attributes per ME is 16.
           zhoneGponOmciOnuRebootTable 1.3.6.1.4.1.5504.5.14.1.17 no-access
Table of objects used to reboot an ONU via the OMCI.
                 zhoneGponOmciOnuRebootEntry 1.3.6.1.4.1.5504.5.14.1.17.1 no-access
A single entry in the table
                     zhoneGponOmciOnuReboot 1.3.6.1.4.1.5504.5.14.1.17.1.1 integer read-only
Set this object to 'reboot to reboot an ONU. The reboot command is sent to the ONU over the OMCI. Successful transmission of the reboot command to the ONU does no guarantee the ONU will reboot. The ONU may be in a fatal lockup which prevents the processing of the reboot command. Enumeration: 'none': 0, 'reboot': 1.
           zhoneGponOmciOnuPortAdminTable 1.3.6.1.4.1.5504.5.14.1.18 no-access
Table of objects used to configure the admin state of a physical port on an ONU.
                 zhoneGponOmciOnuPortAdminEntry 1.3.6.1.4.1.5504.5.14.1.18.1 no-access
A single entry in the table
                     zhoneGponOmciOnuPortAdminMEId 1.3.6.1.4.1.5504.5.14.1.18.1.1 unsigned32 no-access
This is the ID of the managed entity in the ITU G984.4 standard.
                     zhoneGponOmciOnuPortAdminLogicalPort 1.3.6.1.4.1.5504.5.14.1.18.1.2 unsigned32 no-access
This specifies which entity on the ONT we want. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
                     zhoneGponOmciOnuPortAdminState 1.3.6.1.4.1.5504.5.14.1.18.1.3 integer read-only
This object is used to place an ONU physical port in a DOWN or UP state. This state is a configuration parameter and is preserved. Enumeration: 'down': 2, 'none': 0, 'up': 1.
                     zhoneGponOmciOnuPortAdminAutoDetect 1.3.6.1.4.1.5504.5.14.1.18.1.4 integer read-only
This object is used to set the auto detection rate of an ONU physical port.This state is a configuration parameter and is preserved. Enumeration: 'none': 0, 'hundredFull': 3, 'auto': 1, 'thousandHalf': 8, 'autoFull': 10, 'tenHalf': 6, 'tenAuto': 5, 'hundredHalf': 7, 'autoHalf': 11, 'tenFull': 2, 'thousandFull': 4, 'hundredAuto': 12, 'thousandAuto': 9.
           zhoneGponOmciOnuImageUpgradeTable 1.3.6.1.4.1.5504.5.14.1.19 no-access
This table is used to perform ONU software upgrades. There is one table entry for each ONU. Each ONU is addressed by it's ifIndex.
                 zhoneGponOmciOnuImageUpgradeEntry 1.3.6.1.4.1.5504.5.14.1.19.1 no-access
An entry for one ONU.
                     zhoneGponOmciOnuImageUpgradeAction 1.3.6.1.4.1.5504.5.14.1.19.1.1 integer read-only
Which software upgrade action to perform. Enumeration: 'none': 0, 'activate': 2, 'downloadActivate': 4, 'abortDownload': 6, 'activateCommit': 7, 'download': 1, 'commit': 3, 'downloadActivateCommit': 5.
                     zhoneOnuOmciImageUpgradeFilename 1.3.6.1.4.1.5504.5.14.1.19.1.2 octet string read-only
Name of file to be loaded downloaded to ONU. Required on download actions.
                     zhoneGponOmciOnuImageUpgradePartition 1.3.6.1.4.1.5504.5.14.1.19.1.3 integer read-only
Optional on all actions. Indicates which partition or 'none'in which case default is to use inactive partition for download or activate action, or to the uncommitted partion for commit action. On a read, returns the partition used for current or latest upgrade. Enumeration: 'none': 0, 'partitionNumber0': 1, 'partitionNumber1': 2.
                     zhoneOnuOmciImageUpgradeImageVersionPartition0 1.3.6.1.4.1.5504.5.14.1.19.1.4 octet string read-only
Version information for s/w image loaded into partition 0.
                     zhoneOnuOmciImageUpgradeImageVersionPartition1 1.3.6.1.4.1.5504.5.14.1.19.1.5 octet string read-only
Version information for s/w image loaded into partition 1.
                     zhoneOnuOmciImageUpgradeIsCommittedPartition0 1.3.6.1.4.1.5504.5.14.1.19.1.6 integer read-only
Current commit status for partition 0. Enumeration: 'false': 2, 'none': 0, 'true': 1.
                     zhoneOnuOmciImageUpgradeIsCommittedPartition1 1.3.6.1.4.1.5504.5.14.1.19.1.7 integer read-only
Current commit status for partition 1. Enumeration: 'false': 2, 'none': 0, 'true': 1.
                     zhoneOnuOmciImageUpgradeIsActivatedPartition0 1.3.6.1.4.1.5504.5.14.1.19.1.8 integer read-only
Current activated status for partition 0. Enumeration: 'false': 2, 'none': 0, 'true': 1.
                     zhoneOnuOmciImageUpgradeIsActivatedPartition1 1.3.6.1.4.1.5504.5.14.1.19.1.9 integer read-only
Current activated status for partition 1. Enumeration: 'false': 2, 'none': 0, 'true': 1.
                     zhoneOnuOmciImageUpgradeIsValidPartition0 1.3.6.1.4.1.5504.5.14.1.19.1.10 integer read-only
Current valid status for partition 0. Enumeration: 'false': 2, 'none': 0, 'true': 1.
                     zhoneOnuOmciImageUpgradeIsValidPartition1 1.3.6.1.4.1.5504.5.14.1.19.1.11 integer read-only
Current valid status for partition 0. Enumeration: 'false': 2, 'none': 0, 'true': 1.
                     zhoneOnuOmciImageUpgradeDownloadStatus 1.3.6.1.4.1.5504.5.14.1.19.1.12 onuupgradestate read-only
Current s/w image download status.
                     zhoneGponOmciOnuImageUpgradeModel 1.3.6.1.4.1.5504.5.14.1.19.1.13 octet string read-only
Model id read from this onu.
                     zhoneGponOmciOnuImageUpgradeStartTime 1.3.6.1.4.1.5504.5.14.1.19.1.14 octet string read-only
Start time, as ascii string, of most recent upgrade.
                     zhoneGponOmciOnuImageUpgradeWillBeActivated 1.3.6.1.4.1.5504.5.14.1.19.1.15 truthvalue read-only
If true, the downloaded image will be activated when download completes.
                     zhoneGponOmciOnuImageUpgradeWillBeCommitted 1.3.6.1.4.1.5504.5.14.1.19.1.16 truthvalue read-only
If true, this image will be committed on successful activation.
                     zhoneGponOmciOnuImageUpgradeType 1.3.6.1.4.1.5504.5.14.1.19.1.17 integer read-only
Indicates the reason for the upgrade. Enumeration: 'bulk': 3, 'auto': 2, 'none': 0, 'manual': 1.
                     zhoneGponOmciOnuImageDownloadProgressPercentage 1.3.6.1.4.1.5504.5.14.1.19.1.18 integer read-only
Image download progress. This object is only valid during image download.
                     zhoneGponOmciOnuImageUpgradeMethod 1.3.6.1.4.1.5504.5.14.1.19.1.19 integer read-only
The download method used for upgrading this ONU. TFTP is used where possible, else OMCI (default). Enumeration: 'tftp': 2, 'omci': 1.
           zhoneGponOltStatusTable 1.3.6.1.4.1.5504.5.14.1.20 no-access
Current Status of OLT as reported from the Gpon Driver.
                 zhoneGponOltStatusEntry 1.3.6.1.4.1.5504.5.14.1.20.1 no-access
Row in the zhoneGponOltStatusTable.
                     zhoneGponOltOpticTemperature 1.3.6.1.4.1.5504.5.14.1.20.1.1 integer32 read-only
Internally measured Tranceiver Temperature of the OLT in Celcius.
                     zhoneGponOltOpticVoltage 1.3.6.1.4.1.5504.5.14.1.20.1.2 unsigned32 read-only
Internally measured Tranceiver Supply Voltage of the OLT in Volts. The measured value will be in the order of hundredths of Volts.
                     zhoneGponOltOpticTxBiasCurrent 1.3.6.1.4.1.5504.5.14.1.20.1.3 unsigned32 read-only
Measured Tx Bias current per OLT in milli Amperes.
                     zhoneGponOltOpticTxPower 1.3.6.1.4.1.5504.5.14.1.20.1.4 integer32 read-only
Measured Tx Output Power of the OLT in dB. The measured value will be in tenths of dB.
                     zhoneGponOltOpticStatus 1.3.6.1.4.1.5504.5.14.1.20.1.5 integer read-only
When the End Of Life(EOL) Alarm bit is set an alarm will be raised. Alarm is set at about 150% of original current.Alarm will be level Major. It will be cleared when the SFP is replaced, or when the Alarm bit is cleared. Warning indication will be provided when user asks for status. Warning is set when EOL is at about 130% original current. Enumeration: 'oltactive': 16, 'sfpnotpresent': 8, 'alarm': 4, 'warning': 2, 'ok': 1.
                     zhoneGponOltOpticAlarms 1.3.6.1.4.1.5504.5.14.1.20.1.6 bits read-only
Bitmap of alarm conditions present, as reported from the SFP. Bits: 'txPwrHigh': 6, 'tempLow': 1, 'txBiasLow': 5, 'rxPwrLow': 9, 'tempHigh': 0, 'vccLow': 3, 'txBiasHigh': 4, 'vccHigh': 2, 'rxPwrHigh': 8, 'txPwrLow': 7.
                     zhoneGponOltStatusWord 1.3.6.1.4.1.5504.5.14.1.20.1.7 bits read-only
The bit-coded OLT status word. Bits: 'outOfService': 9, 'rogueOnuRssi': 11, 'rogueOn': 10, 'lossOfSignal': 6, 'noAlarm': 0, 'sgmiiGeLinkDown': 12, 'notused8': 8, 'notused4': 4, 'notused5': 5, 'notused7': 7, 'notused1': 1, 'notused2': 2, 'notused3': 3.
                     zhoneGponOltConfiguredOnuCount 1.3.6.1.4.1.5504.5.14.1.20.1.8 unsigned32 read-only
Count of the ONUs on this OLT where onu-added = TRUE.
                     zhoneGponOltActiveOnuCount 1.3.6.1.4.1.5504.5.14.1.20.1.9 unsigned32 read-only
Number of ONUs on this OLT currently in operational state UP.
           zhoneGponOltDbaStatusTable 1.3.6.1.4.1.5504.5.14.1.21 no-access
Current status of OLT DBA as reported from CAC.
                 zhoneGponOltDbaStatusEntry 1.3.6.1.4.1.5504.5.14.1.21.1 no-access
Row in the zhoneGponOltDbaStatusTable.
                     zhoneGponOltDbaTotalAvailableBw 1.3.6.1.4.1.5504.5.14.1.21.1.1 unsigned32 read-only
The Total Available DBA Bandwidth per OLT.The unit is Kilobits( 1000 bits).
                     zhoneGponOltDbaTotalAvailableCompensatedCbrBw 1.3.6.1.4.1.5504.5.14.1.21.1.2 unsigned32 read-only
The Total Available DBA Compensated CBR bandwidth per OLT. The unit is Kilobits(1000 bits).
                     zhoneGponOltDbaAllocatedUbrBw 1.3.6.1.4.1.5504.5.14.1.21.1.3 unsigned32 read-only
The Total Available DBA Allocated UBR bandwidth per OLT. The unit is Kilobits(1000 bits).
                     zhoneGponOltDbaAllocatedCbrBw 1.3.6.1.4.1.5504.5.14.1.21.1.4 unsigned32 read-only
The Total Available DBA Allocated CBR bandwidth per OLT. The unit is Kilobits(1000 bits).
                     zhoneGponOltDbaAllocatedCompensatedCbrBw 1.3.6.1.4.1.5504.5.14.1.21.1.5 unsigned32 read-only
The Total Available DBA Allocated CBR Compensated bandwidth per OLT. The unit is Kilobits(1000 bits).
                     zhoneGponOltDbaAllocatedAssuredBw 1.3.6.1.4.1.5504.5.14.1.21.1.6 unsigned32 read-only
The Total Available DBA Allocated Assured bandwidth per OLT. The unit is Kilobits(1000 bits).
                     zhoneGponOltDbaAllocatedNonAssuredBw 1.3.6.1.4.1.5504.5.14.1.21.1.7 unsigned32 read-only
The Total Available DBA Allocated Non Assured bandwidth per OLT. The unit is Kilobits(1000 bits).
                     zhoneGponOltDbaAllocatedBestEffortBw 1.3.6.1.4.1.5504.5.14.1.21.1.8 unsigned32 read-only
The Total Available DBA Allocated Best Effort bandwidth per OLT. The unit is Kilobits(1000 bits).
                     zhoneGponOltDbaMaxAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.9 unsigned32 read-only
Maximum number of alloc-Ids supported by this OLT.
                     zhoneGponOltDbaAvailAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.10 unsigned32 read-only
Total number of available alloc-Ids for this OLT.
                     zhoneGponOltDbaUsedAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.11 unsigned32 read-only
Total number of alloc-Ids in use for this OLT.
                     zhoneGponOltDbaMaxDbaAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.12 unsigned32 read-only
Maximum number of DBA alloc-Ids supported by this OLT.
                     zhoneGponOltDbaAvailDbaAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.13 unsigned32 read-only
Total number of available DBA alloc-Ids for this OLT.
                     zhoneGponOltDbaUsedDbaAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.14 unsigned32 read-only
Total number of DBA alloc-Ids in use for this OLT.
                     zhoneGponOltDbaTotalOltGemPorts 1.3.6.1.4.1.5504.5.14.1.21.1.15 unsigned32 read-only
Total number GEM Ports currently on this OLT.
                     zhoneGponOltDbaLastCacRc 1.3.6.1.4.1.5504.5.14.1.21.1.16 gponcacrc read-only
This object contains the result code of the last GPON CAC request for the OLT.
           zhoneGponUpgradeByStateTable 1.3.6.1.4.1.5504.5.14.1.22 no-access
Information about onu upgrade.
                 zhoneGponUpgradeByStateEntry 1.3.6.1.4.1.5504.5.14.1.22.1 no-access
Row in onu upgrade table.
                     zhoneGponUpgradeOlt 1.3.6.1.4.1.5504.5.14.1.22.1.1 integer32 no-access
Olt number on the card.
                     zhoneGponUpgradeOnu 1.3.6.1.4.1.5504.5.14.1.22.1.2 integer32 no-access
Onu number within olt.
                     zhoneGponUpgradeModel 1.3.6.1.4.1.5504.5.14.1.22.1.3 octet string read-only
Model ID returned from this Onu.
                     zhoneGponUpgradeStartTime 1.3.6.1.4.1.5504.5.14.1.22.1.4 octet string read-only
Last upgrade start time, as ascii string
                     zhoneGponUpgradeIfIndex 1.3.6.1.4.1.5504.5.14.1.22.1.5 interfaceindex read-only
Onu ifIndex
                     zhoneGponUpgradeByStateOnuState 1.3.6.1.4.1.5504.5.14.1.22.1.6 onuupgradestate read-only
The actual upgrade state of the onu.
                     zhoneGponUpgradeByStateWillBeActivated 1.3.6.1.4.1.5504.5.14.1.22.1.7 truthvalue read-only
If true, the image will be activated if download is successful.
                     zhoneGponUpgradeByStateWillBeCommitted 1.3.6.1.4.1.5504.5.14.1.22.1.8 truthvalue read-only
If true, image will be committed after successful activation.
                     zhoneGponUpgradeByStateUpgradeType 1.3.6.1.4.1.5504.5.14.1.22.1.9 integer read-only
Indicates the reason for the upgrade. Enumeration: 'bulk': 3, 'auto': 2, 'none': 0, 'manual': 1.
                     zhoneGponUpgradeByStatePartition 1.3.6.1.4.1.5504.5.14.1.22.1.10 integer read-only
If upgrade has been requested, this is the image partition of the latest upgrade. Enumeration: 'none': 0, 'partitionNumber0': 1, 'partitionNumber1': 2.
                     zhoneGponUpgradeProgressPercentage 1.3.6.1.4.1.5504.5.14.1.22.1.11 integer read-only
Image download progress. This object is only valid during image download.
                     zhoneGponUpgradeByStateMethod 1.3.6.1.4.1.5504.5.14.1.22.1.12 integer read-only
The download method used for upgrading this ONU. TFTP is used where possible, else OMCI (default). Enumeration: 'tftp': 2, 'omci': 1.
           zhoneGponCmd 1.3.6.1.4.1.5504.5.14.1.23
                 zhoneGponCmdOperation 1.3.6.1.4.1.5504.5.14.1.23.1 integer read-write
GPON Command operation. This object must be supplied with each operation. Enumeration: 'onuApply': 1, 'onuEnableAutoCfg': 5, 'onuSet2default': 4, 'onuResync': 2, 'onuDisableAutoCfg': 6, 'onuReboot': 3.
                 zhoneGponCmdFilterMask 1.3.6.1.4.1.5504.5.14.1.23.2 bits read-write
GPON Command operation filter. This object must be supplied with each operation. Bits: 'filterSlot': 1, 'filterOlt': 2, 'filterShelf': 0, 'filterOn': 3.
                 zhoneGponCmdShelf 1.3.6.1.4.1.5504.5.14.1.23.3 unsigned32 read-write
GPON command 'SHELF' filter value. This parameter is for future use and is currently not supported.
                 zhoneGponCmdSlot 1.3.6.1.4.1.5504.5.14.1.23.4 unsigned32 read-write
GPON command 'SLOT' filter value. If this object is included in the SNMP packet then the associated filter must be enabled in the filter (zhoneGponCmdFilterMask).
                 zhoneGponCmdOlt 1.3.6.1.4.1.5504.5.14.1.23.5 unsigned32 read-write
GPON command 'OLT' filter value. If this object is included in the SNMP packet then the associated filter must be enabled in the filter (zhoneGponCmdFilterMask).
                 zhoneGponCmdOnu 1.3.6.1.4.1.5504.5.14.1.23.6 unsigned32 read-write
GPON command 'ONU' filter value. If this object is included in the SNMP packet then the associated filter must be enabled in the filter (zhoneGponCmdFilterMask).
           zhoneGponOltStatisticsTable 1.3.6.1.4.1.5504.5.14.1.24 no-access
Per OLT statistics gathered from Broadlight device.
                 zhoneGponOltStatisticsEntry 1.3.6.1.4.1.5504.5.14.1.24.1 no-access
Per OLT statistics gathered from Broadlight device.
                     zhoneGponOltStatisticsUpstreamValidGemFrames 1.3.6.1.4.1.5504.5.14.1.24.1.1 counter64 read-only
UpstreamValidGemFrames counter.
                     zhoneGponOltStatisticsUpstreamDiscardedFrames 1.3.6.1.4.1.5504.5.14.1.24.1.2 counter64 read-only
UpstreamDiscardedFrames counter.
                     zhoneGponOltStatisticsUpstreamGemFrames 1.3.6.1.4.1.5504.5.14.1.24.1.3 counter64 read-only
UpstreamGemFrames counter.
                     zhoneGponOltStatisticsUpstreamOmciFrames 1.3.6.1.4.1.5504.5.14.1.24.1.4 counter64 read-only
UpstreamOmciFrames counter.
                     zhoneGponOltStatisticsUpstreamPloamFrames 1.3.6.1.4.1.5504.5.14.1.24.1.5 counter64 read-only
UpstreamPloamFrames counter.
                     zhoneGponOltStatisticsUpstreamIdlePloamFrames 1.3.6.1.4.1.5504.5.14.1.24.1.6 counter64 read-only
UpstreamIdlePloamFrames counter.
                     zhoneGponOltStatisticsDownstreamValidGemFrames 1.3.6.1.4.1.5504.5.14.1.24.1.7 counter64 read-only
DownstreamValidGemFrames counter.
                     zhoneGponOltStatisticsDownstreamDiscardedFrames 1.3.6.1.4.1.5504.5.14.1.24.1.8 counter64 read-only
DownstreamDiscardedFrames counter.
                     zhoneGponOltStatisticsDownstreamGemFrames 1.3.6.1.4.1.5504.5.14.1.24.1.9 counter64 read-only
DownstreamGemFrames counter.
                     zhoneGponOltStatisticsDownstreamOmciFrames 1.3.6.1.4.1.5504.5.14.1.24.1.10 counter64 read-only
DownstreamOmciFrames counter.
                     zhoneGponOltStatisticsDownstreamPloamFrames 1.3.6.1.4.1.5504.5.14.1.24.1.11 counter64 read-only
DownstreamPloamFrames counter.
                     zhoneGponOltStatisticsDownstreamIdlePloamFrames 1.3.6.1.4.1.5504.5.14.1.24.1.12 counter64 read-only
DownstreamIdlePloamFrames counter.
                     zhoneGponOltStatisticsDownstreamPonValidEthernetPkts 1.3.6.1.4.1.5504.5.14.1.24.1.13 counter64 read-only
DownstreamPonValidEthernetPkts counter.
                     zhoneGponOltStatisticsDownstreamPonCpuPkts 1.3.6.1.4.1.5504.5.14.1.24.1.14 counter64 read-only
DownstreamPonCpuPkts counter.
                     zhoneGponOltStatisticsDownstreamTxBytes 1.3.6.1.4.1.5504.5.14.1.24.1.15 counter64 read-only
DownstreamTxBytes counter.
                     zhoneGponOltStatisticsUpstreamPonValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.16 counter64 read-only
Description.
                     zhoneGponOltStatisticsUpstreamPonValidNotIdlePloams 1.3.6.1.4.1.5504.5.14.1.24.1.17 counter64 read-only
UpstreamPonValidNotIdlePloams counter.
                     zhoneGponOltStatisticsUpstreamPonErrorPloams 1.3.6.1.4.1.5504.5.14.1.24.1.18 counter64 read-only
UpstreamPonErrorPloams counter.
                     zhoneGponOltStatisticsUpstreamPonInvalidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.19 counter64 read-only
UpstreamPonInvalidPkts counter.
                     zhoneGponOltStatisticsUpstreamDroppedPktsInactivePorts 1.3.6.1.4.1.5504.5.14.1.24.1.20 counter64 read-only
UpstreamDroppedPktsInactivePorts counter.
                     zhoneGponOltStatisticsUpstreamDroppedPloamsFifoFull 1.3.6.1.4.1.5504.5.14.1.24.1.21 counter64 read-only
UpstreamDroppedPloamsFifoFull counter.
                     zhoneGponOltStatisticsDownstreamTmValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.22 counter64 read-only
DownstreamTmValidPkts counter.
                     zhoneGponOltStatisticsDownstreamTmCrcPkts 1.3.6.1.4.1.5504.5.14.1.24.1.23 counter64 read-only
DownstreamTmCrcPkts counter.
                     zhoneGponOltStatisticsDownstreamTmDroppedCpuPkts 1.3.6.1.4.1.5504.5.14.1.24.1.24 counter64 read-only
DownstreamTmDroppedCpuPkts counter.
                     zhoneGponOltStatisticsDownstreamTmMacLookupMiss 1.3.6.1.4.1.5504.5.14.1.24.1.25 counter64 read-only
DownstreamTmMacLookupMiss counter.
                     zhoneGponOltStatisticsDownstreamTmPktsForwardedFromHmToPon 1.3.6.1.4.1.5504.5.14.1.24.1.26 counter64 read-only
DownstreamTmPktsForwardedFromHmToPon counter.
                     zhoneGponOltStatisticsDownstreamTmPktsDroppedGemPidNotEnabled 1.3.6.1.4.1.5504.5.14.1.24.1.27 counter64 read-only
DownstreamTmPktsDroppedGemPidNotEnabled counter.
                     zhoneGponOltStatisticsDownstreamTmQ0ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.28 counter64 read-only
DownstreamTmQ0ValidPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ0DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.29 counter64 read-only
DownstreamTmQ0DroppedPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ1ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.30 counter64 read-only
DownstreamTmQ1ValidPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ1DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.31 counter64 read-only
DownstreamTmQ1DroppedPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ2ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.32 counter64 read-only
DownstreamTmQ2ValidPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ2DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.33 counter64 read-only
DownstreamTmQ2DroppedPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ3ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.34 counter64 read-only
DownstreamTmQ3ValidPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ3DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.35 counter64 read-only
DownstreamTmQ3DroppedPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ4ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.36 counter64 read-only
DownstreamTmQ4ValidPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ4DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.37 counter64 read-only
DownstreamTmQ4DroppedPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ5ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.38 counter64 read-only
DownstreamTmQ5ValidPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ5DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.39 counter64 read-only
DownstreamTmQ5DroppedPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ6ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.40 counter64 read-only
DownstreamTmQ6ValidPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ6DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.41 counter64 read-only
DownstreamTmQ6DroppedPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ7ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.42 counter64 read-only
DownstreamTmQ7ValidPkts counter.
                     zhoneGponOltStatisticsDownstreamTmQ7DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.43 counter64 read-only
DownstreamTmQ7DroppedPkts counter.
                     zhoneGponOltStatisticsUpstreamTmDroppedCpuPkts 1.3.6.1.4.1.5504.5.14.1.24.1.44 counter64 read-only
UpstreamTmDroppedCpuPkts counter.
                     zhoneGponOltStatisticsUpstreamTmDroppedPktsCrcError 1.3.6.1.4.1.5504.5.14.1.24.1.45 counter64 read-only
UpstreamTmDroppedPktsCrcError counter.
                     zhoneGponOltStatisticsUpstreamTmDroppedPktsSecurity 1.3.6.1.4.1.5504.5.14.1.24.1.46 counter64 read-only
UpstreamTmDroppedPktsSecurity counter.
                     zhoneGponOltStatisticsUpstreamTmLearnFailures 1.3.6.1.4.1.5504.5.14.1.24.1.47 counter64 read-only
UpstreamTmLearnFailures counter.
                     zhoneGponOltStatisticsUpstreamTmQ0ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.48 counter64 read-only
UpstreamTmQ0ValidPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ0DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.49 counter64 read-only
UpstreamTmQ0DroppedPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ1ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.50 counter64 read-only
UpstreamTmQ1ValidPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ1DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.51 counter64 read-only
UpstreamTmQ1DroppedPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ2ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.52 counter64 read-only
UpstreamTmQ2ValidPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ2DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.53 counter64 read-only
UpstreamTmQ2DroppedPkts
                     zhoneGponOltStatisticsUpstreamTmQ3ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.54 counter64 read-only
UpstreamTmQ3ValidPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ3DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.55 counter64 read-only
UpstreamTmQ3DroppedPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ4ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.56 counter64 read-only
UpstreamTmQ4ValidPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ4DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.57 counter64 read-only
UpstreamTmQ4DroppedPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ5ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.58 counter64 read-only
UpstreamTmQ5ValidPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ5DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.59 counter64 read-only
UpstreamTmQ5DroppedPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ6ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.60 counter64 read-only
UpstreamTmQ6ValidPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ6DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.61 counter64 read-only
UpstreamTmQ6DroppedPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ7ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.62 counter64 read-only
UpstreamTmQ7ValidPkts counter.
                     zhoneGponOltStatisticsUpstreamTmQ7DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.63 counter64 read-only
UpstreamTmQ7DroppedPkts counter.
                     zhoneGponOltStatisticsClearStats 1.3.6.1.4.1.5504.5.14.1.24.1.64 truthvalue read-write
Clear all statistics for the selected interface.
           zhoneGponUpstreamOntStatisticsTable 1.3.6.1.4.1.5504.5.14.1.25 no-access
Per ONT Upstream Statistics provided by Broadlight.
                 zhoneGponUpstreamOntStatisticsEntry 1.3.6.1.4.1.5504.5.14.1.25.1 no-access
Per ONT Upstream Statistics provided by Broadlight.
                     zhoneGponUpstreamOntStatisticsUpstreamBipErrors 1.3.6.1.4.1.5504.5.14.1.25.1.1 counter64 read-only
UpstreamOntStatisticsUpstreamBipErrors counter.
                     zhoneGponUpstreamOntStatisticsFecCorrectedBytes 1.3.6.1.4.1.5504.5.14.1.25.1.2 counter64 read-only
UpstreamOntStatisticsFecCorrectedBytes counter.
                     zhoneGponUpstreamOntStatisticsFecCorrectedCodewords 1.3.6.1.4.1.5504.5.14.1.25.1.3 counter64 read-only
UpstreamOntStatisticsFecCorrectedCodewords counter.
                     zhoneGponUpstreamOntStatisticsFecUncorrectedCodewords 1.3.6.1.4.1.5504.5.14.1.25.1.4 counter64 read-only
UpstreamOntStatisticsFecUncorrectedCodewords counter.
                     zhoneGponUpstreamOntStatisticsTotalRxCodewords 1.3.6.1.4.1.5504.5.14.1.25.1.5 counter64 read-only
UpstreamOntStatisticsTotalRxCodewords counter.
                     zhoneGponUpstreamOntStatisticsUnreceivedBursts 1.3.6.1.4.1.5504.5.14.1.25.1.6 counter64 read-only
UpstreamOntStatisticsUnreceivedBursts counter.
                     zhoneGponUpstreamOntStatisticsBipErrors 1.3.6.1.4.1.5504.5.14.1.25.1.7 counter64 read-only
UpstreamOntStatisticsBipErrors counter.
                     zhoneGponUpstreamOntStatisticsRemoteBipErrors 1.3.6.1.4.1.5504.5.14.1.25.1.8 counter64 read-only
UpstreamOntStatisticsRemoteBipErrors counter.
                     zhoneGponUpstreamOntStatisticsDriftOfWindowIndications 1.3.6.1.4.1.5504.5.14.1.25.1.9 counter64 read-only
UpstreamOntStatisticsDriftOfWindowIndications counter.
                     zhoneGponUpstreamOntStatisticsMessageErrorMessage 1.3.6.1.4.1.5504.5.14.1.25.1.10 counter64 read-only
UpstreamOntStatisticsMessageErrorMessage counter.
                     zhoneGponUpstreamOntStatisticsClearStats 1.3.6.1.4.1.5504.5.14.1.25.1.11 truthvalue read-write
Clear all statistics for the selected interface.
 zhoneGponOltMIB 1.3.6.1.4.1.5504.6.111
This is the Zhone GPON mib which contains SNMP objects for GPON ONU configuration, alarms, and status.It also includes the GPON OLT status information.
     zhoneGponOltConfigGroup 1.3.6.1.4.1.5504.9.1.10
GPON OLT Config group
     zhoneGponOnuConfigGroup 1.3.6.1.4.1.5504.9.1.11
GPON ONU Config group
     zhoneGponPortConfigGroup 1.3.6.1.4.1.5504.9.1.12
GPON Port Config group
     zhoneGponAllocIdGroup 1.3.6.1.4.1.5504.9.1.13
GPON Allocation ID group
     zhoneGponSerialNoGroup 1.3.6.1.4.1.5504.9.1.14
GPON Serial Number group
     zhoneGponOnuStatusGroup 1.3.6.1.4.1.5504.9.1.15
GPON ONU Status group
     zhoneOnuOmciMeProfileGroup 1.3.6.1.4.1.5504.9.1.16
GPON OMCI ONU ME Profile group
     zhoneOnuOmciGenericProfileGroup 1.3.6.1.4.1.5504.9.1.17
GPON OMCI ONU Generic Profile group
     zhoneOnuOmciSpecificProfileGroup 1.3.6.1.4.1.5504.9.1.18
GPON OMCI ONU Specific Profile group
     zhoneGponOmciOnuAlarmsGroup 1.3.6.1.4.1.5504.9.1.19
GPON OMCI ONU Alarms group
     zhoneGponTrapGroup 1.3.6.1.4.1.5504.9.1.20
Gpon Trap objects.
     zhoneGponTrafficProfileGroup 1.3.6.1.4.1.5504.9.1.21
Gpon Traffic Profile objects.
     zhoneGponPortStatusGroup 1.3.6.1.4.1.5504.9.1.22
Gpon Port Status objects.
     zhoneGponOmciStatusGroup 1.3.6.1.4.1.5504.9.1.24
Gpon Omci Status objects.
     zhoneGponOmciOnuRebootGroup 1.3.6.1.4.1.5504.9.1.25
Gpon Omci Reboot objects.
     zhoneGponOmciOnuPortAdminGroup 1.3.6.1.4.1.5504.9.1.26
Gpon Port Admin objects.
     zhoneGponOmciOnuImageUpgradeGroup 1.3.6.1.4.1.5504.9.1.27
Group of ONU Image Upgrade objects
     zhoneGponOltStatusGroup 1.3.6.1.4.1.5504.9.1.28
GPON OLT Status Group.
     zhoneGponeOltDbaStatusGroup 1.3.6.1.4.1.5504.9.1.29
GPON OLT Dba Status Group.
     zhoneGponCmdGroup 1.3.6.1.4.1.5504.9.1.31
GPON Command objects
     zhoneGponOltStatisticsGroup 1.3.6.1.4.1.5504.9.1.32
Gpon OLT Statistics objects.
     zhoneGponUpstreamOntStatisticsGroup 1.3.6.1.4.1.5504.9.1.33
Gpon Upstream ONT Statistics objects.
     zhoneGponDeprecated 1.3.6.1.4.1.5504.9.1.34
Gpon Deprecated objects.