ZYXEL-AS-MIB: View SNMP OID List / Download MIB

VENDOR: ZYXEL COMMUNICATIONS CORP.


 Home MIB: ZYXEL-AS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 zyxel 1.3.6.1.4.1.890
         products 1.3.6.1.4.1.890.1
             accessSwitch 1.3.6.1.4.1.890.1.5
                 accessSwitchCommon 1.3.6.1.4.1.890.1.5.1
                     accessSwitchMgnt 1.3.6.1.4.1.890.1.5.1.1
                         accessSwitchSystemCurrentStatus 1.3.6.1.4.1.890.1.5.1.1.1 integer read-only
This variable indicates the status of the system. The sysCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sysNoDefect 2 sysOverHeat 3 sysFanRpmLow 4 sysVoltageLow 5 sysThermalSensorFailure
                         accessSwitchProblemCause 1.3.6.1.4.1.890.1.5.1.1.2 displaystring read-only
The variable is the description of sytsem problem.
                         accessSwitchSystemTemperature 1.3.6.1.4.1.890.1.5.1.1.3 displaystring read-only
The variable is the current temperature in Celsius of the system.
                         accessSwitchFanRpmTable 1.3.6.1.4.1.890.1.5.1.1.4 no-access
A table that contains rpm information about the fans.
                             accessSwitchFanRpmEntry 1.3.6.1.4.1.890.1.5.1.1.4.1 no-access
A list of rpm information for each fan.
                                 accessSwitchFanRpmIndex 1.3.6.1.4.1.890.1.5.1.1.4.1.1 integer read-only
The identity of the fan.
                                 accessSwitchFanRpmCurValue 1.3.6.1.4.1.890.1.5.1.1.4.1.2 integer read-only
The current rpm of the fan.
                                 accessSwitchFanRpmMaxValue 1.3.6.1.4.1.890.1.5.1.1.4.1.3 integer read-only
The maximum rpm ever performed by the fan.
                                 accessSwitchFanRpmMinValue 1.3.6.1.4.1.890.1.5.1.1.4.1.4 integer read-only
The minimum rpm ever performed by the fan.
                                 accessSwitchFanRpmLowThresh 1.3.6.1.4.1.890.1.5.1.1.4.1.5 integer read-only
The low threshold of the rpm of the fan. If the current rpm is less than the threshold, the device will initiate the fanRpmLow trap.
                                 accessSwitchFanRpmDescr 1.3.6.1.4.1.890.1.5.1.1.4.1.6 displaystring read-only
The description of the fan (e.g. location, function, etc.).
                         accessSwitchVoltageTable 1.3.6.1.4.1.890.1.5.1.1.5 no-access
A table that contains voltage information about the system.
                             accessSwitchVoltageEntry 1.3.6.1.4.1.890.1.5.1.1.5.1 no-access
A list of voltage information for each sensor.
                                 accessSwitchVoltageIndex 1.3.6.1.4.1.890.1.5.1.1.5.1.1 integer read-only
The identity of the sensor.
                                 accessSwitchVoltageCurValue 1.3.6.1.4.1.890.1.5.1.1.5.1.2 integer read-only
The current voltage detected by the sensor (in milli-voltage).
                                 accessSwitchVoltageMaxValue 1.3.6.1.4.1.890.1.5.1.1.5.1.3 integer read-only
The maximum voltage ever detected by the sensor (in milli-voltage).
                                 accessSwitchVoltageMinValue 1.3.6.1.4.1.890.1.5.1.1.5.1.4 integer read-only
The minimum voltage ever detected by the sensor (in milli-voltage).
                                 accessSwitchVoltageNominalValue 1.3.6.1.4.1.890.1.5.1.1.5.1.5 integer read-only
The nominal voltage which the power should supply (in milli-voltage).
                                 accessSwitchVoltageLowThresh 1.3.6.1.4.1.890.1.5.1.1.5.1.6 integer read-only
The low threshold of the voltage. If the current voltage is less than the threshold, the device will initiate the voltageLow trap.
                                 accessSwitchVoltageDescr 1.3.6.1.4.1.890.1.5.1.1.5.1.7 displaystring read-only
The description of the voltage (e.g. location, nominal value, etc.).
                         accessSwitchSysTempTable 1.3.6.1.4.1.890.1.5.1.1.6 no-access
A table that contains temperature information about system.
                             accessSwitchSysTempEntry 1.3.6.1.4.1.890.1.5.1.1.6.1 no-access
A list of temperature information for each sensor.
                                 accessSwitchSysTempIndex 1.3.6.1.4.1.890.1.5.1.1.6.1.1 integer read-only
The identity of the sensor.
                                 accessSwitchSysTempCurValue 1.3.6.1.4.1.890.1.5.1.1.6.1.2 integer read-only
The current temperature detected in Celsius by the sensor.
                                 accessSwitchSysTempMaxValue 1.3.6.1.4.1.890.1.5.1.1.6.1.3 integer read-only
The maximum temperature ever detected in Celsius by the sensor.
                                 accessSwitchSysTempMinValue 1.3.6.1.4.1.890.1.5.1.1.6.1.4 integer read-only
The minimum temperature ever detected in Celsius by the sensor.
                                 accessSwitchSysTempHighThresh 1.3.6.1.4.1.890.1.5.1.1.6.1.5 integer read-only
The high threshold of the temperature in Celsius. If the current temperature is higher than the threshold, the device will initiate the overheat trap.
                                 accessSwitchSysTempDescr 1.3.6.1.4.1.890.1.5.1.1.6.1.6 displaystring read-only
The description of the temperature sensor (e.g. location, function, etc.).
                         accessSwitchMaintenance 1.3.6.1.4.1.890.1.5.1.1.7 integer read-write
The managed object is for system maintenance. When the EMS wants to trigger the system maitenance operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: config save BIT 2: reset BIT 3: local loopback test BIT 4: remote loopback test
                         accessSwitchMaintenancePort 1.3.6.1.4.1.890.1.5.1.1.8 integer read-write
The port which the maintenance operation should be performed on. The value of 0 means the maintenance should be performed on the system.
                         accessSwitchMaxNumOfStaticVlans 1.3.6.1.4.1.890.1.5.1.1.9 integer read-only
The maximum number of static VLANs which the system supports
                         acccessSwitchChassisId 1.3.6.1.4.1.890.1.5.1.1.10 integer read-write
The chassis Id of the module
                         accessSwitchSlotId 1.3.6.1.4.1.890.1.5.1.1.11 asslotnum read-write
The slot Id of the module
                         accessSwitchModuleType 1.3.6.1.4.1.890.1.5.1.1.12 asmoduletype read-only
The type of the module
                         accessSwitchFWVersion 1.3.6.1.4.1.890.1.5.1.1.13 displaystring read-only
The firmware version of the access switch.
                         accessSwitchDriverVersion 1.3.6.1.4.1.890.1.5.1.1.14 displaystring read-only
The driver version of the access port in this access switch
                         accessSwitchModemCodeVersion 1.3.6.1.4.1.890.1.5.1.1.15 displaystring read-only
The modem code version of the access port in this access switch
                         accessSwitchDSLConfOps 1.3.6.1.4.1.890.1.5.1.1.16 integer read-write
The managed object is for xDSL line configuration. When the EMS wants to issue the desired operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: enable port BIT 2: disable port BIT 3: set DSL mode BIT 4: set profile
                         accessSwitchDSLConfTarget 1.3.6.1.4.1.890.1.5.1.1.17 octet string read-write
The managed object is used for identify the target on which the line configuration should be performed. The target is encoded as: Byte 1~4: reserved Byte 5~7: each octet specifies a set of eight ports, with the first octet specifying ports 1 through 8, etc. Byte 8~10: reserved
                         accessSwitchDSLConfProfileName 1.3.6.1.4.1.890.1.5.1.1.18 displaystring read-write
The DSL profile name
                         accessSwitchDSLConfMode 1.3.6.1.4.1.890.1.5.1.1.19 integer read-write
The DSL mode. The semantic for each bit is: Bit 1: ADSL, G.lite Bit 2: ADSL, G.dmt Bit 3: ADSL, T1.413 Bit 4: ADSL, Auto
                         asPacketForwardingTable 1.3.6.1.4.1.890.1.5.1.1.20 no-access
This table includes the configuration of packet forwarding.
                               asPacketForwardingEntry 1.3.6.1.4.1.890.1.5.1.1.20.1 no-access
An entry in asPacketForwardingTable.
                                   asPacketForwardingPortList 1.3.6.1.4.1.890.1.5.1.1.20.1.1 portlist read-write
The list defines the ports to which the packets will be forwarded.
                         asDhcpRelayEnable 1.3.6.1.4.1.890.1.5.1.1.21 integer read-write
Enable/disable DHCP relay function. Enumeration: 'enable': 1, 'disable': 2.
                         asDhcpRelayOption82Enable 1.3.6.1.4.1.890.1.5.1.1.22 integer read-write
Enable/disable the relay agent information option. Enumeration: 'enable': 1, 'disable': 2.
                         asDhcpRelayOption82Info 1.3.6.1.4.1.890.1.5.1.1.23 displaystring read-write
User specific relay agent information.
                         asMaxNumOfDhcpServers 1.3.6.1.4.1.890.1.5.1.1.24 integer read-only
The maximum number of DHCP servers.
                         asDhcpServerTable 1.3.6.1.4.1.890.1.5.1.1.25 no-access
A table that contains DHCP server information.
                               asDhcpServerEntry 1.3.6.1.4.1.890.1.5.1.1.25.1 no-access
The entry of DHCP server table.
                                   asDhcpServerIp 1.3.6.1.4.1.890.1.5.1.1.25.1.1 ipaddress read-only
The IP address of the DHCP server.
                                   asDhcpServerRowStatus 1.3.6.1.4.1.890.1.5.1.1.25.1.2 rowstatus read-write
The row status of the DHCP server entry.
                         asMaxNumberOfRadiusServers 1.3.6.1.4.1.890.1.5.1.1.28 integer read-only
The max number of the RADIUS Servers.
                         asRadiusServerTable 1.3.6.1.4.1.890.1.5.1.1.29 no-access
A table that contains Radius Server information.
                               asRadiusServerEntry 1.3.6.1.4.1.890.1.5.1.1.29.1 no-access
The entry of Radius Server table.
                                   asRadiusServerIndex 1.3.6.1.4.1.890.1.5.1.1.29.1.1 integer read-only
The identity of the RADIUS server.
                                   asRadiusServerIp 1.3.6.1.4.1.890.1.5.1.1.29.1.2 ipaddress read-write
The IP address of the Radius Server.
                                   asRadiusServerPort 1.3.6.1.4.1.890.1.5.1.1.29.1.3 integer read-write
The UDP port of the Radius Server.
                                   asRadiusSharedSecret 1.3.6.1.4.1.890.1.5.1.1.29.1.4 displaystring read-write
The shared secret of the Radius Server.
                                   asRadiusServerRowStatus 1.3.6.1.4.1.890.1.5.1.1.29.1.5 rowstatus read-write
The row status of the Radius Server entry.
                         asDot1xEnable 1.3.6.1.4.1.890.1.5.1.1.30 integer read-write
Enable/disable the 802.1x function. Enumeration: 'enable': 1, 'disable': 2.
                         asDot1xPortTable 1.3.6.1.4.1.890.1.5.1.1.31 no-access
This table includes the configuration of 802.1x.
                               asDot1xPortEntry 1.3.6.1.4.1.890.1.5.1.1.31.1 no-access
An entry in asDot1xPortTable.
                                   asDot1xPortEnable 1.3.6.1.4.1.890.1.5.1.1.31.1.1 integer read-write
The option defines if the port enables 802.1x settings. Enumeration: 'enable': 1, 'disable': 2.
                                   asDot1xPortControl 1.3.6.1.4.1.890.1.5.1.1.31.1.2 integer read-write
The configuration defines the 802.1x port control type. Enumeration: 'auto': 1, 'forceUnAuth': 3, 'forceAuth': 2.
                                   asDot1xPortReAuthEnable 1.3.6.1.4.1.890.1.5.1.1.31.1.3 integer read-write
The option defines if the port enables 802.1x re-authentication. Enumeration: 'on': 1, 'off': 2.
                                   asDot1xPortReAuthPeriod 1.3.6.1.4.1.890.1.5.1.1.31.1.4 integer read-write
The configuration defines the 802.1x re-authentication period for each port.
                     accessSwitchStats 1.3.6.1.4.1.890.1.5.1.2
                         asMacStats 1.3.6.1.4.1.890.1.5.1.2.1
                             asMacDisplayTarget 1.3.6.1.4.1.890.1.5.1.2.1.1 integer read-write
This managed object is a filter used for identify the target from which the MAC addresses are learned in macTable. The target should be IfIndex which is used for identifying subscriber ports (e.g. 300 means all ports in slot 3 and 301 means port 1 in slot 3).
                             asMacTable 1.3.6.1.4.1.890.1.5.1.2.1.2 no-access
A table that contains information about unicast entries for which the bridge has forwarding and/or filtering information. This information is used by the transparent bridging function in determining how to propagate a received frame.
                                 asMacEntry 1.3.6.1.4.1.890.1.5.1.2.1.2.1 no-access
An entry of asMacTable.
                                     asMacAddress 1.3.6.1.4.1.890.1.5.1.2.1.2.1.1 macaddress read-only
A unicast MAC address for which the bridge has forwarding and/or filtering information.
                                     asMacPort 1.3.6.1.4.1.890.1.5.1.2.1.2.1.2 integer read-only
The port from which the mac address has been learned.
                                     asMacStatus 1.3.6.1.4.1.890.1.5.1.2.1.2.1.3 integer read-only
The status of this entry. Enumeration: 'learned': 3, 'other': 1, 'self': 4, 'invalid': 2, 'mgmt': 5.
                   reboot 1.3.6.1.4.1.890.1.50.1
Send a message to the manager that the system is going to reboot. The variable is the reason why the system reboots.
                   systemShutdown 1.3.6.1.4.1.890.1.50.2
Send a message to the manager that the system is going to shutdown. The variable is the reason that causes the system to shutdown.
                   overheat 1.3.6.1.4.1.890.1.50.3
Send a message to the manager that the system is overheated. The variable in the binding list is the current temperature in Celsius of the system.
                   overheatOver 1.3.6.1.4.1.890.1.50.4
Send a message to the manager that the overheated condition is over. The variable in the binding list is the current temperature in Celsius of the system.
                   errLog 1.3.6.1.4.1.890.1.50.5
Send a message to the manager that an error log is created in system. The variable in the binding list is the content of the error log.
                   fanRpmLow 1.3.6.1.4.1.890.1.50.6
Send a message to the manager that the rpm of the fan is too low. The variable in the binding list is the current rpm of the fan.
                   fanRpmNormal 1.3.6.1.4.1.890.1.50.7
Send a message to the manager that the low-rpm condition of the fan is over. The variable in the binding list is the current rpm of the fan.
                   voltageOutOfRange 1.3.6.1.4.1.890.1.50.8
Send a message to the manager that the voltage of the system is out of range. The variable in the binding list is the current voltage in volt of the system.
                   voltageNormal 1.3.6.1.4.1.890.1.50.9
Send a message to the manager that the low-voltage condition is over. The variable in the binding list is the current voltage in volt of the system.
                   systemMaintenanceFailure 1.3.6.1.4.1.890.1.50.10
Send a message to the manager that the system maintence operation fail. The variable in the variable binding indicates the problem.
                   configChange 1.3.6.1.4.1.890.1.50.11
Send a message to the manager that the system configuration data is changed.
                   thermalSensorFailure 1.3.6.1.4.1.890.1.50.12
The trap signifies that the thermal sensor failed.