ZTE-AN-IEEE1588-MIB: View SNMP OID List / Download MIB

VENDOR: ZHONGXING TELECOM CO.,LTD. (ABBR. ZTE)


 Home MIB: ZTE-AN-IEEE1588-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 zxAnIeee1588Mib 1.3.6.1.4.1.3902.1082.120.15
The MIB module for the management of IEEE1588 .
       zxAnIeee1588GlobalObjects 1.3.6.1.4.1.3902.1082.120.15.1
           zxAnIeee1588Capabilities 1.3.6.1.4.1.3902.1082.120.15.1.1 bits read-only
The IEEE1588 capabilities of this equipment. The bit value 1 means the function represented by this bit is supported by this equipment. bit 0: value 1 means the following changes, adding zxAnPtpRemoteSrcPriority to the zxAnPtpRemoteSrcTable, adding zxAn1588LocalUtcTime to the zxAnIeee1588TimeStatusInfoObjs, adding zxAnPtpProtocolIpAddrPfxLen, zxAnPtpProtocolGatewayIpAddrType and zxAnPtpProtocolGatewayIpAddress to the zxAnPtpTable, adding zxAnSyncTime1ppsSrcFormat, zxAnSyncTime1ppsSrcCurrentQL, zxAnSyncTime1ppsSrcTimeAccuracy and zxAnSyncTime1ppsSrcTimeSrcType to the zxAnSyncTime1ppsSrcTable. bit 1: value 1 means the following changes, adding zxAnSyncTime1ppsSrcDlyCompensate to the zxAnSyncTime1ppsSrcTable. NOTE: No recommended to display it in NMS. Bits: 'from201602To201603': 0, 'add1ppsSrcDelayCompensation': 1.
           zxAnIeee1588AlmThreshObjects 1.3.6.1.4.1.3902.1082.120.15.1.11
                 zxAn1588FreqQLThresh 1.3.6.1.4.1.3902.1082.120.15.1.11.1 integer read-write
System frequency quality level threshold. A zxAnAccuracyDegradedAlm alarm will be generated when system frequency quality level is below the following threshold. qlprc(2): quality level of primary reference clock, it is defined in recommendation G.811. qlssua(4): quality level of type I/V slave clock, it is defined in recommendation G.812. qlssub(8): quality level of type VI slave clock, it is defined in recommendation G.812. qlsec(11): quality level of SDH equipment clock, it is defined in recommendation G.813. Enumeration: 'qlprc': 2, 'qlsec': 11, 'qlssua': 4, 'qlssub': 8.
                 zxAnPtpClockTraceClassThresh 1.3.6.1.4.1.3902.1082.120.15.1.11.2 integer32 read-write
PTP clock traceability class threshold. A zxAnPtpClockTCBelowThreshAlm alarm will be generated when PTP traceability clock class is below threshold.
                 zxAn1ppsInputSignalQLThresh 1.3.6.1.4.1.3902.1082.120.15.1.11.3 integer read-write
1PPS input signal quality level threshold. A zxAn1ppsInSignalQlBelowThreshAlm alarm will be generated when 1PPS input signal quality level of '1PPS+ToD' port is below the following threshold. locked(1): 1PPS input signal source is locked with grandmaster at this time. qlprc(2): quality level of primary reference clock, it is defined in recommendation G.811. 1PPS input signal is in holdover state at this time by using PRC. qlssua(4): quality level of type I/V slave clock, it is defined in recommendation G.812. 1PPS input signal is in holdover state at this time by using SSU-A. qlssub(8): quality level of type VI slave clock, it is defined in recommendation G.812. 1PPS input signal is in holdover state at this time by using SSU-B. qlsec(11): quality level of SDH equipment clock, it is defined in recommendation G.813. 1PPS input signal is in holdover state at this time by using SEC. Enumeration: 'qlprc': 2, 'qlsec': 11, 'locked': 1, 'qlssua': 4, 'qlssub': 8.
           zxAnIeee1588TimeStatusInfoObjs 1.3.6.1.4.1.3902.1082.120.15.1.12
                 zxAn1588TimeAccuracyDegradAlmRsn 1.3.6.1.4.1.3902.1082.120.15.1.12.1 integer no-access
The time accuracy degraded alarm reason. A zxAn1588TimeAccuracyDegradeAlm alarm will be generated because for the following threshold. freqLol(1): frequency loss of lock. freqQualityLevelBelowThresh(2): frequency quality level below threshold. Enumeration: 'freqLol': 1, 'freqQualityLevelBelowThresh': 2.
                 zxAn1588TimeSourceType 1.3.6.1.4.1.3902.1082.120.15.1.12.2 integer read-only
The current time source type. none(1): no time source. ptp(2): PTP time source. oneppsPlusTod: 1PPS+ToD time source. Enumeration: 'none': 1, 'oneppsPlusTod': 3, 'ptp': 2.
                 zxAn1588TimeSourceId 1.3.6.1.4.1.3902.1082.120.15.1.12.3 displaystring read-only
The current time source identification. It indicates the PTP time source ID when zxAn1588TimeSourceType is ptp(1). It indicates the 1PPS+ToD time source ID when zxAn1588TimeSourceType is oneppsPlusTod(2). If zxAn1588TimeSourceType is none(1), the attribute value is empty string.
                 zxAn1588LocalTimeStatus 1.3.6.1.4.1.3902.1082.120.15.1.12.4 integer read-only
The local time status. freeRun(1): the local time has never been synchronized with any time source. synchronizing(2): the local time is synchronizing with a time source. locked(3): the local time has been synchronized with a time source. holdoverInspecification(4): the local time is no longer synchronized with a time source and is using information obtained while it was previously synchronized or other information sources were still available, to maintain performance within desired specification. It is defined in recommendation G.8275.1 appendix V. holdoverOutOfSpecification(5): the local time is no longer synchronized with a time source and, while it may be using information obtained while it was previously synchronized or other information sources were still available, it is unable to maintain performance within desired specification. It is defined in recommendation G.8275.1 appendix V. holdover(6): the local time is no longer synchronized with a time source, this value is only used for zxAn1588LocalTimeStatusChanged trap. Enumeration: 'holdoverOutOfSpecification': 5, 'locked': 3, 'holdoverInSpecification': 4, 'synchronizing': 2, 'holdover': 6, 'freeRun': 1.
                 zxAn1588LocalClockFreqStatus 1.3.6.1.4.1.3902.1082.120.15.1.12.5 integer read-only
The local clock frequency status. freerun(1): the local clock frequency is in free-run state. locked(2): the local clock frequency is in locked state. holdover(3): the local clock frequency is in holdover state. Enumeration: 'freeRun': 1, 'locked': 2, 'holdover': 3.
                 zxAn1588LocalClockFreqQltyLvl 1.3.6.1.4.1.3902.1082.120.15.1.12.6 integer read-only
The local clock frequency quality level. qlprc(2): quality level of primary reference clock, it is defined in recommendation G.811. 1PPS input signal is in holdover state at this time by using PRC. qlssua(4): quality level of type I/V slave clock, it is defined in recommendation G.812. qlssub(8): quality level of type VI slave clock, it is defined in recommendation G.812. qlsec(11): quality level of SDH equipment clock, it is defined in recommendation G.813. Enumeration: 'qlprc': 2, 'qlsec': 11, 'qlssua': 4, 'qlssub': 8.
                 zxAn1588PtpMessageReceiveStatus 1.3.6.1.4.1.3902.1082.120.15.1.12.7 integer read-only
The PTP message receiving status. normal(1): the PTP message receiving status is normal. annocMessageMissed(2): the PTP announcement message is missed. syncMessageMissed(3): the PTP synchronization message is missed. annocAndSyncMessagesMissed(4): the PTP announcement and synchronization messages are all missed. Enumeration: 'syncMessageMissed': 3, 'annocAndSyncMessagesMissed': 4, 'annocMessageMissed': 2, 'normal': 1.
                 zxAn1588LastTimeSourceType 1.3.6.1.4.1.3902.1082.120.15.1.12.8 integer read-only
The last time source type. none(1): no time source. ptp(2): PTP time source. oneppsPlusTod: 1PPS+ToD time source. Enumeration: 'none': 1, 'oneppsPlusTod': 3, 'ptp': 2.
                 zxAn1588LastTimeSourceId 1.3.6.1.4.1.3902.1082.120.15.1.12.9 displaystring read-only
The last time source identification. It indicates the PTP time source ID when zxAn1588TimeSourceType is ptp(1). It indicates the 1PPS+ToD time source ID when zxAn1588TimeSourceType is oneppsPlusTod(2). If zxAn1588TimeSourceType is none(1), the attribute value is empty string.
                 zxAn1588LocalUtcTime 1.3.6.1.4.1.3902.1082.120.15.1.12.10 displaystring read-only
The UTC time of Local clock. The format is yyyy-mm-dd HH:MM:SS.For example, 2001-01-01 02:22:33.
                 zxAn1588LastLocalTimeStatus 1.3.6.1.4.1.3902.1082.120.15.1.12.11 integer read-only
The last local time status. freeRun(1): the local time has never been synchronized with any time source. synchronizing(2): the local time is synchronizing with a time source. locked(3): the local time has been synchronized with a time source. holdoverInspecification(4): the local time is no longer synchronized with a time source and is using information obtained while it was previously synchronized or other information sources were still available, to maintain performance within desired specification. It is defined in recommendation G.8275.1 appendix V. holdoverOutOfSpecification(5): the local time is no longer synchronized with a time source and, while it may be using information obtained while it was previously synchronized or other information sources were still available, it is unable to maintain performance within desired specification. It is defined in recommendation G.8275.1 appendix V. holdover(6): the local time is no longer synchronized with a time source, this value is only used for zxAn1588LocalTimeStatusChanged trap. Enumeration: 'holdoverOutOfSpecification': 5, 'locked': 3, 'holdoverInSpecification': 4, 'synchronizing': 2, 'holdover': 6, 'freeRun': 1.
           zxAnIeee1588TimeStatusConfObjs 1.3.6.1.4.1.3902.1082.120.15.1.13
                 zxAnIeee1588TimeStatusDftPri1 1.3.6.1.4.1.3902.1082.120.15.1.13.1 integer32 read-write
The default value of priority 1 delivered to PTP master. This value will be used when OLT is in holdover state.
                 zxAnIeee1588TimeStatusDftPri2 1.3.6.1.4.1.3902.1082.120.15.1.13.2 integer32 read-write
The default value of priority 2 delivered to PTP master, This value will be used when OLT is in holdover state.
                 zxAnIeee1588TimeStatusDftClkCls 1.3.6.1.4.1.3902.1082.120.15.1.13.3 integer32 read-write
The default value of clock class delivered to PTP master, This value will be used when OLT is in holdover state.
       zxAnIeee1588Objects 1.3.6.1.4.1.3902.1082.120.15.2
           zxAnIeee1588PtpObjects 1.3.6.1.4.1.3902.1082.120.15.2.1
               zxAnIeee1588PtpGlobalObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.1
                   zxAnPtpMasterObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1
                       zxAnPtpMstDomainId 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.1 integer32 read-only
The domain identification of the master. It is a logic number and the range is from 0 to 255, the value 0 indicates the default domain.
                       zxAnPtpMstIsLeap59 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.2 integer read-only
In PTP systems whose epoch is the PTP epoch, the value 'yes' indicates that the last minute of the current UTC day contains 59 seconds, the value 'no' indicates that the last minute of the current UTC day does not contain 59 seconds or the epoch is not PTP epoch. Enumeration: 'yes': 1, 'no': 2.
                       zxAnPtpMstIsLeap61 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.3 integer read-only
In PTP systems whose epoch is the PTP epoch, the value 'yes' indicates that the last minute of the current UTC day contains 61 seconds, the value 'no' indicates that the last minute of the current UTC day does not contain 61 seconds or the epoch is not PTP epoch. Enumeration: 'yes': 1, 'no': 2.
                       zxAnPtpMstIsTimeTraceable 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.4 integer read-only
The value 'yes' indicates that the current UTC offset can be traced to a primary reference and 'no' otherwise. Enumeration: 'yes': 1, 'no': 2.
                       zxAnPtpMstIsFreqTraceable 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.5 integer read-only
The value 'yes' indicates that the time frequency can be traced to a primary reference and 'no' otherwise. Enumeration: 'yes': 1, 'no': 2.
                       zxAnPtpMstIsUtcOffsetValid 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.6 integer read-only
The value 'yes' indicates that the current UTC offset is known to be valid and 'no' otherwise. Enumeration: 'yes': 1, 'no': 2.
                       zxAnPtpMstCurrentUtcOffset 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.7 integer32 read-only
The current UTC offset between TAI(International Atomic Time) and UTC.
                       zxAnPtpMstClockId 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.8 octet string read-only
The master clock identity. This attribute value is hexadecimal data.
                       zxAnPtpMstGrdmstClockId 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.9 octet string read-only
The grandmaster clock identity. This attribute value is hexadecimal data.
                       zxAnPtpMstGrdmstIsPtpTimescale 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.10 integer read-only
The value 'yes' indicates that the clock timescale of the grandmaster clock is PTP and 'no' otherwise. Enumeration: 'yes': 1, 'no': 2.
                       zxAnPtpMstGrdmstPriority1 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.11 integer32 read-only
The grandmaster clock priority 1. The value 0 indicates the highest priority.
                       zxAnPtpMstGrdmstPriority2 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.12 integer32 read-only
The grandmaster clock priority 2. The value 0 indicates the highest priority.
                       zxAnPtpMstGrdmstClockTraceClass 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.13 integer32 read-only
The grandmaster clock traceability class of the time or frequency distributed. The value 0 indicates the best traceability class.
                       zxAnPtpMstGrdmstClockAccuracy 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.14 integer32 read-only
The grandmaster clock accuracy. The value 0 indicates the highest clock accuracy.
                       zxAnPtpMstGrdmstClockOslv 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.15 integer32 read-only
The grandmaster clock offset scaled log variance. It is computed based on the theory of Allan deviation.
                       zxAnPtpMstGrdmstTraversedClocks 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.16 integer32 read-only
The clocks traversed between the local clock and the grandmaster clock.
                       zxAnPtpMstGrdmstTimeSource 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.17 integer read-only
The source of time used by the grandmaster clock. Enumeration: 'atomicClock': 16, 'ntp': 80, 'handset': 96, 'internalOscillator': 160, 'other': 144, 'terrestrialRadio': 48, 'gps': 32, 'ptp': 64.
                       zxAnPtpMstSourcePortLocation 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.18 integer read-only
The source port location. uplinkCard(1): it means that the PTP master source port is located at the uplink card. masterControlCard(2): it means that the PTP master source port is located at the master control card. slaveControlCard(3): it means that the PTP master source port is located at the slave control card. Enumeration: 'uplinkCard': 1, 'slaveControlCard': 3, 'masterControlCard': 2.
               zxAnPtpIfConfTable 1.3.6.1.4.1.3902.1082.120.15.2.1.7 no-access
The IEEE 1588 PTP port table.
                   zxAnPtpIfConfEntry 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1 no-access
The IEEE 1588 PTP port entry.
                       zxAnPtpIfConfClockId 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.1 octet string read-only
The PTP port clock identity. This attribute value is hexadecimal data.
                       zxAnPtpIfConfNumber 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.2 integer32 read-only
The PTP port number.
                       zxAnPtpIfConfState 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.3 integer read-only
The PTP port state. Enumeration: 'uncalibrated': 8, 'passive': 7, 'slave': 9, 'preMaster': 5, 'disabled': 3, 'master': 6, 'listening': 4, 'initializing': 1, 'faulty': 2.
                       zxAnPtpIfConfMinDelayReqInterval 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.4 integer read-only
The minimum interval between successive Delay_Req messages. us31250 means interval 2**(-5)s us62500 means interval 2**(-4)s us125000 means interval 2**(-3)s us250000 means interval 2**(-2)s us500000 means interval 2**(-1)s oneSecond means interval 2**(0)s Enumeration: 'us62500': 2, 'us31250': 1, 'us250000': 4, 'oneSecond': 6, 'us500000': 5, 'us125000': 3.
                       zxAnPtpIfConfAnnounceInterval 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.6 integer read-only
The interval between successive Announce messages. us31250 means interval 2**(-5)s us62500 means interval 2**(-4)s us125000 means interval 2**(-3)s us250000 means interval 2**(-2)s us500000 means interval 2**(-1)s oneSecond means interval 2**(0)s Enumeration: 'us62500': 2, 'us31250': 1, 'us250000': 4, 'oneSecond': 6, 'us500000': 5, 'us125000': 3.
                       zxAnPtpIfConfMaxLossAnnounceMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.7 integer32 read-only
The maximum number of Announce messages loss.
                       zxAnPtpIfConfSyncInterval 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.8 integer read-only
The interval between successive synchronization messages. us31250 means interval 2**(-5)s us62500 means interval 2**(-4)s us125000 means interval 2**(-3)s us250000 means interval 2**(-2)s us500000 means interval 2**(-1)s oneSecond means interval 2**(0)s Enumeration: 'us62500': 2, 'us31250': 1, 'us250000': 4, 'oneSecond': 6, 'us500000': 5, 'us125000': 3.
                       zxAnPtpIfConfLocalPriority 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.13 integer32 read-only
The PTP port local priority.
                       zxAnPtpIfConfPtpMsgProtocolType 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.21 integer read-only
The PTP message protocol type. ipv4(1): it means the PTP messages is IPv4 protocol. ethernet(2): it means the PTP messages is Ethernet protocol. Enumeration: 'ethernet': 2, 'ipv4': 1.
                       zxAnPtpIfConfAddressType 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.22 integer read-only
The PTP port address type. multicast(1): it means the PTP port address type is multicast. unicast(2): it means the PTP port address type is unicast. Enumeration: 'unicast': 2, 'multicast': 1.
                       zxAnPtpIfConfMsgForwardOption 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.23 integer read-only
The PTP message forwarding option. forwardable(1): it means the PTP messages is preferable to forward the PTP messages through the PTP port. nonforwardable(2): it means the PTP messages must never be forwarded through the PTP port. Enumeration: 'forwardable': 1, 'nonforwardable': 2.
                       zxAnPtpIfConfDelayCompensation 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.24 integer32 read-only
The PTP port delay compensation.
                       zxAnPtpIfConfAdminStatus 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.25 integer read-only
The PTP port administrative status. Enables or disables the PTP port. Enumeration: 'disabled': 2, 'enabled': 1.
                       zxAnPtpIfConfRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.50 rowstatus read-only
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
               zxAnPtpProfileObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.20
                     zxAnPtpProfileGlobalObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.20.1
                         zxAnPtpPrfSystemPtpPrf 1.3.6.1.4.1.3902.1082.120.15.2.1.20.1.1 displaystring read-write
The system PTP profile name. Refers to 'zxAnPtpPrfName'. An empty string indicates no binding any profile.
                     zxAnPtpPrfTable 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2 no-access
The IEEE 1588 PTP profile table.
                         zxAnPtpPrfEntry 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1 no-access
The IEEE 1588 PTP profile entry.
                             zxAnPtpPrfName 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.1 displaystring no-access
The PTP profile name.
                             zxAnPtpPrfPriority2 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.3 integer32 read-only
The PTP priority 2. The value 0 indicates the highest priority.
                             zxAnPtpPrfDomainNumber 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.4 integer32 read-only
The PTP domain number.
                             zxAnPtpPrfLocalPriority 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.5 integer32 read-only
The PTP local priority. The value 1 indicates the highest priority.
                             zxAnPtpPrfMaxStepsRemoved 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.6 integer32 read-only
The PTP maximum steps removed. The parameter is defined in [IEEE1588] is used to indicate the distance between a clock and the grandmaster clock in the network. It was originally intended to be used as a helpful tool to detect cyclic paths that may occur in PTP systems. By default it is required that a clock not qualify any Announce messages where the stepsRemoved field is equal to, or greater than, 255 in order to ensure that rogue frames are extinguished.
                             zxAnPtpPrfBmcaOption 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.7 integer read-only
The PTP BMCA (best master clock algorithm) option. g82751(1): BMCA complies with G.8275.1. ieee1588(2): BMCA complies with IEEE 1588. Enumeration: 'g82751': 1, 'ieee1588': 2.
                             zxAnPtpPrfTraceOption 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.8 integer read-only
The PTP trace option. g82751(1): PTP trace complies with G.8275.1. g82751note3(2): PTP trace complies with G.8275.1 note 3. ieee1588(3): PTP trace complies with IEEE 1588. Enumeration: 'g82751': 1, 'ieee1588': 3, 'g82751note3': 2.
                             zxAnPtpPrfHoldoverInTimeout 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.9 integer32 read-only
The holdover-in timeout. The value 0 indicates that the system clock do not enter into the holdover-in status.
                             zxAnPtpPrfRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.50 rowstatus read-only
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
               zxAnPtpStatsObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.25
                     zxAnPtpIfStatsTable 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2 no-access
The IEEE 1588 PTP port statistics table.
                         zxAnPtpIfStatsEntry 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1 no-access
The IEEE 1588 PTP port statistics entry.
                             zxAnPtpIfStatsAnnounceMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.1 counter32 read-only
The number of PTP announce messages.
                             zxAnPtpIfStatsSyncMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.2 counter32 read-only
The number of PTP synchronization messages.
                             zxAnPtpIfStatsDelayReqMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.3 counter32 read-only
The number of PTP delay_req messages.
                             zxAnPtpIfStatsDelayRespMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.4 counter32 read-only
The number of PTP delay_resp messages.
                             zxAnPtpIfStatsFollowUpMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.5 counter32 read-only
The number of PTP follow_up messages.
           zxAnIeee15881ppsObjects 1.3.6.1.4.1.3902.1082.120.15.2.2
               zxAnSyncTime1ppsSrcTable 1.3.6.1.4.1.3902.1082.120.15.2.2.3 no-access
This table includes 1PPS source information in NE equipment.
                   zxAnSyncTime1ppsSrcEntry 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1 no-access
An entry in zxAnSyncTime1ppsSrcTable. to create a 1pps source,it must comply with the multi-variables usage rule - all the mib variables related to same fuction must be in one snmp set operation. the variables have two type mandatory and optional: Mandatory variables must be in the one snmp set operation. Optional variables may be in the one snmp set operation with the mandatory variables, but must not be used alone. case 1 - to create 1PPS signal source from 1PPS port: -Mandatory: zxAnSyncTime1ppsSrcRack, zxAnSyncTime1ppsSrcShelf, zxAnSyncTime1ppsSrcSlot, zxAnSyncTime1ppsSrcSignalType, zxAnSyncTime1ppsSrcPortType, zxAnSyncTime1ppsSrcPort, zxAnSyncTime1ppsSrcPriority, zxAnSyncTime1ppsSrcRowStatus, -Optional: case 3 - to destroy 1PPS signal -Mandatory: zxAnSyncTime1ppsSrcRowStatus,
                       zxAnSyncTime1ppsSrcId 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.1 integer32 no-access
This '1PPS+ToD' source id.
                       zxAnSyncTime1ppsSrcRack 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.2 integer32 read-only
This object indicates the rack number.
                       zxAnSyncTime1ppsSrcShelf 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.3 integer32 read-only
This object indicates the shelf number.
                       zxAnSyncTime1ppsSrcSlot 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.4 integer32 read-only
This object indicates the slot number. Only support time card, such as cick.
                       zxAnSyncTime1ppsSrcFirstPtp 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.5 truthvalue read-only
The PTP node provided '1PPS+ToD' siginal is the first node of this slot or not.
                       zxAnSyncTime1ppsSrcSignalType 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.6 integer read-only
The type of '1PPS+ToD' signal source. ptp(1) : 1PPS come from PTP onepps(2) : 1PPS come from physical 1pps port Enumeration: 'onepps': 2, 'ptp': 1.
                       zxAnSyncTime1ppsSrcPriority 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.7 integer32 read-only
The priority of '1PPS+ToD' signal source, value 1 is the highest priority.
                       zxAnSyncTime1ppsSrcPortType 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.8 integer read-only
The '1PPS+ToD' signal source port type. It is valid only for the 'onepps' signal type. typeTtl(1) : physical port type TTL type422(2) : from physical port as RJ45 Enumeration: 'typeTtl': 1, 'type422': 2.
                       zxAnSyncTime1ppsSrcPort 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.9 integer32 read-only
The physical port number. It is valid only for the 'onepps' signal type.
                       zxAnSyncTime1ppsSrcWorkStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.10 integer read-only
The '1PPS+ToD' signal source work status, none(1) : indicates PTP source is invalid. active(2) : indicates PTP source is active, standby(3) : indicates PTP source is standby source, Enumeration: 'active': 2, 'standby': 3, 'none': 1.
                       zxAnSyncTime1ppsSrcValidStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.11 integer read-only
The '1PPS+ToD' singnal source work status. valid(1) : indicates the 1PPS signal is valid invalid(2): indicates the 1PPS signal is invalid When the value is invalid, then zxAnSyncTime1ppsSrcWorkStatus is none. Enumeration: 'valid': 1, 'invalid': 2.
                       zxAnSyncTime1ppsSrcPortStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.12 integer read-only
The '1PPS+ToD' signal source port status. It is valid only for the 'onepps' signal type. If zxAnSyncTime1ppsSrcSignalType is 'ptp', then the value is none. When the value is none or signalLos, then zxAnSyncTime1ppsSrcValidStatus is invalid. Enumeration: 'none': 1, 'signalLos': 3, 'normal': 2.
                       zxAnSyncTime1ppsSrcFormat 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.13 integer read-only
The '1PPS+ToD' singnal source format. unknown(1): it indicates the '1PPS+ToD' signal source format is unknown. gpzda(2): it indicates the '1PPS+ToD' signal source format is GPZDA. gprmc(3): it indicates the '1PPS+ToD' signal source format is GPRMC. cmcc(4): it indicates the '1PPS+ToD' signal source format is CMCC. Enumeration: 'gprmc': 3, 'unknown': 1, 'cmcc': 4, 'gpzda': 2.
                       zxAnSyncTime1ppsSrcCurrentQL 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.14 integer read-only
The '1PPS+ToD' singnal source current quality level. locked(1): 1PPS input signal source is locked with grandmaster at this time. qlprc(2): quality level of primary reference clock, it is defined in recommendation G.811. qlssua(4): quality level of type I/V slave clock, it is defined in recommendation G.812. qlssub(8): quality level of type VI slave clock, it is defined in recommendation G.812. qlsec(11): quality level of SDH equipment clock, it is defined in recommendation G.813. qldnu(15): quality level of unusable clock, it is defined in recommendation G.813. Enumeration: 'locked': 1, 'qlsec': 11, 'qlprc': 2, 'qlssua': 4, 'qlssub': 8, 'qldn': 15.
                       zxAnSyncTime1ppsSrcTimeAccuracy 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.15 integer32 read-only
The '1PPS+ToD' singnal source time accuracy, value 0 indicates the highest accuracy.
                       zxAnSyncTime1ppsSrcTimeSrcType 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.16 integer read-only
The '1PPS+ToD' singnal source time source type. bds(1): the time source type is beidou bavigation satellite system. gps(2): the time source type is global positioning system. ptp(3): the time source type is precision timing protocol system. other(255): the time source type is other system. Enumeration: 'ptp': 3, 'other': 255, 'bds': 1, 'gps': 2.
                       zxAnSyncTime1ppsSrcDlyCompensate 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.17 integer32 read-only
The '1PPS+ToD' delay compensation.
                       zxAnSyncTime1ppsSrcRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.30 rowstatus read-only
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
               zxAnSyncTimeTodSrcTable 1.3.6.1.4.1.3902.1082.120.15.2.2.4 no-access
This table includes TOD source information in NE equipment.
                   zxAnSyncTimeTodSrcEntry 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1 no-access
An entry in zxAnSyncTimeTodSrcTable. to create a TOD source,it must comply with the multi-variables usage rule - all the mib variables related to same fuction must be in one snmp set operation. the variables have two type mandatory and optional: Mandatory variables must be in the one snmp set operation. Optional variables may be in the one snmp set operation with the mandatory variables, but must not be used alone. case 1 - to create tod source from physical tod port: -Mandatory: zxAnSyncTimeTodSrcRack, zxAnSyncTimeTodSrcShelf, zxAnSyncTimeTodSrcSlot, zxAnSyncTimeTodSrcPort, zxAnSyncTimeTodSrcSignalType, zxAnSyncTimeTodSrcRowStatus, -Optional: zxAnSyncTimeTodSrcYearAdjust, case 2 - to destroy tod source -Mandatory: zxAnSyncTimeTodSrcRowStatus,
                       zxAnSyncTimeTodSrcId 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.1 integer32 no-access
This tod source id.
                       zxAnSyncTimeTodSrcRack 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.2 integer32 read-only
This object indicates the rack number.
                       zxAnSyncTimeTodSrcShelf 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.3 integer32 read-only
This object indicates the shelf number.
                       zxAnSyncTimeTodSrcSlot 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.4 integer32 read-only
This object indicates the slot number. Only support time card, such as cick.
                       zxAnSyncTimeTodSrcPort 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.5 integer32 read-only
This object indicates the port number.
                       zxAnSyncTimeTodSrcSignalType 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.6 integer read-only
The signal type of TOD signal source. gps(1) : GPS TOD form chinaMobile(2) : China Mobile Telecom's TOD form chinaUnicom(3) : China Unicom Telecom's TOD form chinaTelecom(4): China Telecom's TOD form Enumeration: 'chinaTelecom': 4, 'chinaUnicom': 3, 'chinaMobile': 2, 'gps': 1.
                       zxAnSyncTimeTodSrcYearAdjust 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.7 integer32 read-only
The year adjustment value of TOD signal source. It is valid only for the 'gps' signal type.
                       zxAnSyncTimeTodSrcPortStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.8 integer read-only
The TOD signal source port status. none(1) : none normal(2) : no alarm signalLos(3) : Loss of TOD Enumeration: 'none': 1, 'signalLos': 3, 'normal': 2.
                       zxAnSyncTimeTodSrcRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.30 rowstatus read-only
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
               zxAnSyncTimeOutputPortTable 1.3.6.1.4.1.3902.1082.120.15.2.2.5 no-access
This table includes 1PPS and TOD signal output ports information in NE equipment.
                   zxAnSyncTimeOutputPortEntry 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1 no-access
An entry in zxAnSyncTimeOutputPortTable. to create a TOD output,it must comply with the multi-variables usage rule - all the mib variables related to same fuction must be in one snmp set operation. the variables have two type mandatory and optional: Mandatory variables must be in the one snmp set operation. Optional variables may be in the one snmp set operation with the mandatory variables, but must not be used alone. case 1 - to create tod output: -Mandatory: zxAnSyncTimeOutputRack, zxAnSyncTimeOutputShelf, zxAnSyncTimeOutputSlot, zxAnSyncTimeOutputPort, zxAnSyncTimeOutputPortEnable, zxAnSyncTimeOutputPortRowStatus, -Optional: case 3 - to destroy tod output -Mandatory: zxAnSyncTimeOutputPortRowStatus,
                       zxAnSyncTimeOutputId 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.1 integer32 no-access
This time output id.
                       zxAnSyncTimeOutputRack 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.2 integer32 read-only
This object indicates the rack number.
                       zxAnSyncTimeOutputShelf 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.3 integer32 read-only
This object indicates the shelf number.
                       zxAnSyncTimeOutputSlot 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.4 integer32 read-only
This object indicates the slot number. Only support pon card.
                       zxAnSyncTimeOutputPort 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.5 integer32 read-only
This object indicates the port number.
                       zxAnSyncTimeOutputPortEnable 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.6 integer read-only
Enables or disables the output port of 1PPS and TOD signal. enable(1) : enable disable(2): disable Enumeration: 'enable': 1, 'disable': 2.
                       zxAnSyncTimeOutputPortPhaseAdjus 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.7 integer32 read-only
The phase adjustment value. It is valid only for the 1PPS signal.
                       zxAnSyncTimeOutputPortRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.30 rowstatus read-only
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
       zxAnIeee1588Notifications 1.3.6.1.4.1.3902.1082.120.15.3
           zxAnIeee1588GlobalTraps 1.3.6.1.4.1.3902.1082.120.15.3.1
               zxAn1588TimeAccuracyDegradeAlm 1.3.6.1.4.1.3902.1082.120.15.3.1.1
A zxAnAccuracyDegradedAlm trap is sent when the agent has detected that the time accuracy has been degraded.
               zxAn1588TimeAccuracyDegradeClr 1.3.6.1.4.1.3902.1082.120.15.3.1.2
A zxAn1588TimeAccuracyDegradeClr trap is sent when the agent has detected that the time accuracy has come into the accurate status.
               zxAn1588TimeSourceChanged 1.3.6.1.4.1.3902.1082.120.15.3.1.3
A zxAn1588TimeSourceChanged trap is sent when the agent has detected that the current time source of IEEE1588 device has been changed to another new time source.
               zxAn1588LocalTimeStatusChanged 1.3.6.1.4.1.3902.1082.120.15.3.1.4
A zxAn1588LocalTimeStatusChanged trap is sent when the agent has detected that the current time status of IEEE1588 device has been changed to another new time status.
           zxAnIeee1588PtpTraps 1.3.6.1.4.1.3902.1082.120.15.3.2
               zxAnPtpNeverSyncAlm 1.3.6.1.4.1.3902.1082.120.15.3.2.1
A zxAnPtpNeverSyncAlm trap is sent when the agent has detected that the PTP clock has never been synchronized with a time source.
               zxAnPtpNeverSyncClr 1.3.6.1.4.1.3902.1082.120.15.3.2.2
A zxAnPtpNeverSyncClr trap is sent when the agent has detected that the PTP clock has been synchronized with a time source.
               zxAnPtpLolAlm 1.3.6.1.4.1.3902.1082.120.15.3.2.3
A zxAnPtpLolAlm trap is sent when the agent has detected that the PTP clock was in the loss of lock status.
               zxAnPtpLolClr 1.3.6.1.4.1.3902.1082.120.15.3.2.4
A zxAnPtpLolClr trap is sent when the agent has detected that the PTP clock has been locked again.
               zxAnPtpClockTCBelowThreshAlm 1.3.6.1.4.1.3902.1082.120.15.3.2.5
A zxAnPtpClockTCBelowThreshAlm trap is sent when the agent has detected that the PTP clock traceability class has been below zxAnPtpClockTraceClassThresh threshold.
               zxAnPtpClockTCBelowThreshClr 1.3.6.1.4.1.3902.1082.120.15.3.2.6
A zxAnPtpClockTCBelowThreshClr trap is sent when the agent has detected that the PTP clock traceability class has not been below zxAnPtpClockTraceClassThresh threshold.
               zxAnPtpAnnounceMsgLostAlm 1.3.6.1.4.1.3902.1082.120.15.3.2.7
A zxAnPtpAnnounceMsgLostAlm trap is sent when the agent has detected that the announce messages lost.
               zxAnPtpAnnounceMsgLostClr 1.3.6.1.4.1.3902.1082.120.15.3.2.8
A zxAnPtpAnnounceMsgLostClr trap is sent when the agent has detected that the announce messages are received again.
           zxAnIeee15881ppsTraps 1.3.6.1.4.1.3902.1082.120.15.3.3
               zxAn1ppsPlusTodLosAlm 1.3.6.1.4.1.3902.1082.120.15.3.3.1
A zxAn1ppsPlusTodLosAlm trap is sent when the agent has detected that the '1PPS+ToD' port was in the loss of signal status.
               zxAn1ppsPlusTodLosClr 1.3.6.1.4.1.3902.1082.120.15.3.3.2
A zxAn1ppsPlusTodLosClr trap is sent when the agent has detected that the '1PPS+ToD' port has restored signal.
               zxAn1ppsInSignalQlBelowThreshAlm 1.3.6.1.4.1.3902.1082.120.15.3.3.3
A zxAn1ppsInSignalQlBelowThreshAlm trap is sent when the agent has detected that the 1PPS input signal quality level of '1PPS+ToD' port has been below zxAn1ppsInputSignalQLThresh threshold.
               zxAn1ppsInSignalQlBelowThreshClr 1.3.6.1.4.1.3902.1082.120.15.3.3.4
A zxAn1ppsInSignalQlBelowThreshClr trap is sent when the agent has detected that the 1PPS input signal quality level of '1PPS+ToD' port has not been below zxAn1ppsInputSignalQLThresh threshold.
       zxAnIeee1588Conformance 1.3.6.1.4.1.3902.1082.120.15.4
           zxAnIeee1588Compliances 1.3.6.1.4.1.3902.1082.120.15.4.1
               zxAnIeee1588Compliance 1.3.6.1.4.1.3902.1082.120.15.4.1.1
The compliance statement for entities which implement the Zte An IEEE1588 MIB. Implementation of this MIB is based on individual product needs.
           zxAnIeee1588Groups 1.3.6.1.4.1.3902.1082.120.15.4.2
               zxAnIeee1588PtpPrfObjectsGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.1
A collection of objects providing IEEE1588 functions.
               zxAnIeee1588PtpIfObjectsGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.2
A collection of objects providing IEEE1588 port functions.
               zxAnIeee15881ppsObjectsGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.3
A collection of global objects providing 1PPS functions.
               zxAnIeee1588PtpMstInfoGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.4
A collection of objects providing PTP master information.
               zxAnIeee1588TimeStatusGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.5
A collection of objects providing time status information.
               zxAnIeee1588PktStatsGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.6
A collection of objects providing packets statistics.
               zxAnIeee1588AlmThreshGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.7
A collection of objects providing alarm thresholds.
               zxAnIeee1588AlmTrapGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.8
A collection of objects providing 1588 alarm functions