ZHONE-SECHTOR100-MIB: View SNMP OID List / Download MIB

VENDOR: ZHONE TECHNOLOGIES


 Home MIB: ZHONE-SECHTOR100-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
         sechtor100Environment 1.3.6.1.4.1.5504.2.4.1.1
All the scalar objects under sechor100Environment are deprecated and replaced by their respective objects indexed by zhoneShelfIndex and zhoneSlotIndex.
             s100FanOperationalStatus 1.3.6.1.4.1.5504.2.4.1.1.1 integer read-only
This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'. Enumeration: 'fanFailure': 2, 'operational': 1.
             s100ThermoAUpperThreshold 1.3.6.1.4.1.5504.2.4.1.1.2 integer32 read-write
This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius.
             s100ThermoBUpperThreshold 1.3.6.1.4.1.5504.2.4.1.1.3 integer32 read-write
This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius.
             s10ThermoALowerThreshold 1.3.6.1.4.1.5504.2.4.1.1.4 integer32 read-write
This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
             s100ThermoBLowerThreshold 1.3.6.1.4.1.5504.2.4.1.1.5 integer32 read-write
This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
             s100ThermoATemperature 1.3.6.1.4.1.5504.2.4.1.1.6 integer32 read-only
The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
             s100ThermoBTemperature 1.3.6.1.4.1.5504.2.4.1.1.7 integer32 read-only
The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
             s100ThermoAOperationalStatus 1.3.6.1.4.1.5504.2.4.1.1.8 integer read-only
The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold. Enumeration: 'overUpperThreshold': 2, 'belowLowerThreshold': 3, 'withinOperationalRange': 1.
             s100ThermoBOperationalStatus 1.3.6.1.4.1.5504.2.4.1.1.9 integer read-only
The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold. Enumeration: 'overUpperThreshold': 2, 'belowLowerThreshold': 3, 'withinOperationalRange': 1.
         sechtor100Traps 1.3.6.1.4.1.5504.2.4.1.2
All Sechtor 100 MIB traps are defined under sechtor100Traps.
             sechtor100TrapsPrefix 1.3.6.1.4.1.5504.2.4.1.2.0
Prefix 0 for Sechtor 100 MIB traps as required by SNMPv2.
                 s100FanStatusChange 1.3.6.1.4.1.5504.2.4.1.2.0.1
This trap is generated whenever the value of s100FanOperationalStatus changes. This trap is deprecated and is replaced by sechtor100FanStatusChange.
                 s100ThermoStatusChange 1.3.6.1.4.1.5504.2.4.1.2.0.2
This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. This trap is deprecated and is replaced by sechtor100ThermoStatusChange.
                 sechtor100FanStatusChange 1.3.6.1.4.1.5504.2.4.1.2.0.3
This trap is generated whenever the value of sechtor100FanOperationalStatus changes. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects.
                 sechtor100ThermoStatusChange 1.3.6.1.4.1.5504.2.4.1.2.0.4
This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects.
         sechtor100ConfigTable 1.3.6.1.4.1.5504.2.4.1.3 no-access
This table contains redundancy variables and environmental variables for monitoring fans and thermometers. For redundancy, the peer MAC address is maintained in this table. Also, one variable specifies whether redundancy is enabled or not. There are two thermometers on the Sechtor 100 board. In this MIB, thermometers 'A' and 'B' are used to differentiate these two thermometers: Thermometer A - the thermometer located near the 750 processor. It is expected that this thermometer have a higher temperature reading than thermometer B because of the heat generated by the processor. It is recommended that a higher upper threshold is set for this thermometer. Thermometer B - the thermometer located near the outlet on the right side of the Sechtor 100 board. The profile for this table will be auto-created as 1/1 with the sechtor100RedundancyEnable variable set to FALSE. This profile should not be deleted except for the following two cases: 1) When a unit operating in simplex mode is intended to be used in duplex mode as the slot 2 of the redundant system. The user needs to create a 1/2 profile. 2) The unit configured as slot 2 of a redundant system is intended to be used in simplex mode. Then the 1/2 profile should be deleted and replaced with a 1/1 profile.
             sechtor100ConfigEntry 1.3.6.1.4.1.5504.2.4.1.3.1 no-access
An entry in the sechtor100ConfigTable.
                 sechtor100PeerMacAddress 1.3.6.1.4.1.5504.2.4.1.3.1.1 macaddress read-write
This is the Mac address of the peer s100 unit.
                 sechtor100RedundancyEnable 1.3.6.1.4.1.5504.2.4.1.3.1.2 truthvalue read-write
Whether or not the redundancy functionality has been enabled. If this value is false, redundancy is not enable.
                 sechtor100FanOperationalStatus 1.3.6.1.4.1.5504.2.4.1.3.1.3 integer read-only
This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'. Enumeration: 'fanFailure': 2, 'operational': 1.
                 sechtor100ThermoAUpperThreshold 1.3.6.1.4.1.5504.2.4.1.3.1.4 integer32 read-write
This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius.
                 sechtor100ThermoBUpperThreshold 1.3.6.1.4.1.5504.2.4.1.3.1.5 integer32 read-write
This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius.
                 sechtor100ThermoALowerThreshold 1.3.6.1.4.1.5504.2.4.1.3.1.6 integer32 read-write
This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
                 sechtor100ThermoBLowerThreshold 1.3.6.1.4.1.5504.2.4.1.3.1.7 integer32 read-write
This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
                 sechtor100ThermoATemperature 1.3.6.1.4.1.5504.2.4.1.3.1.8 integer32 read-only
The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
                 sechtor100ThermoBTemperature 1.3.6.1.4.1.5504.2.4.1.3.1.9 integer32 read-only
The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
                 sechtor100ThermoAOperationalStatus 1.3.6.1.4.1.5504.2.4.1.3.1.10 integer read-only
The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold. Enumeration: 'overUpperThreshold': 2, 'belowLowerThreshold': 3, 'withinOperationalRange': 1.
                 sechtor100ThermoBOperationalStatus 1.3.6.1.4.1.5504.2.4.1.3.1.11 integer read-only
The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold. Enumeration: 'overUpperThreshold': 2, 'belowLowerThreshold': 3, 'withinOperationalRange': 1.
                 sechtor100RowStatus 1.3.6.1.4.1.5504.2.4.1.3.1.12 zhonerowstatus read-only
Used to control row creation and deletion. A row in this table is created using a single SNMP SET request with varbinds for: a) sechtor100RowStatus set to'CreateAndGo', b) the following READ-CREATE object(s): * If 'createAndGo' successfully created a new row, the RowStatus will be 'active'. Subsequent to successful row creation, the RowStatus can be retrieved via an SNMP GET and the returned RowStatus value is active. If the 'createAndGo' was unsuccessful an SNMP error will be returned and a subsequent GET on the non-existent row will also return an SNMP error of noSuchInstance. An SNMP SET with the RowStatus value of 'destroy' indicates that the agent should remove the row from service and then delete it.
 zhoneSechtor100 1.3.6.1.4.1.5504.6.19
MIB module for elements specific to Sechtor 100 products.