ZHONE-PHY-SONET-MIB: View SNMP OID List / Download MIB

VENDOR: ZHONE TECHNOLOGIES


 Home MIB: ZHONE-PHY-SONET-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
     sonetClockTable 1.3.6.1.4.1.5504.5.9.1 no-access
MIB table for clock related configuration for SONET interfaces.
         sonetClockEntry 1.3.6.1.4.1.5504.5.9.1.1 no-access
An entry of the sonetClockEntry. sonetClockEntry is augmented to sonetMediumEntry defined in rfc2558.mib. Whenever a row is instantiated in the sonetMediumTable, a corresponding row will be instantiated in the sonetClockTable.
             sonetClockExternalRecovery 1.3.6.1.4.1.5504.5.9.1.1.1 integer read-write
This variable indicates if external clock recovery is enabled for this SONET interface. The default value is 'enabled'. Enumeration: 'disabled': 2, 'enabled': 1.
             sonetClockTransmitSource 1.3.6.1.4.1.5504.5.9.1.1.2 integer read-write
This variable describes the SONET transmit clock source. Valid values are: loopTiming - transmit clock synthesized from the recovered receive clock. throughTiming - transmit clock is derived from the recovered receive clock of another SONET interface. localTiming - transmit clock synthesized from a local clock source or that an external clock is attached to the box containing the interface. external155MHz - transmit clock synthesized from an external 155.52 MHz source. The default value is 'loopTiming'. 'external155MHz' option is not valid for Sechtor 100. Enumeration: 'localTiming': 3, 'loopTiming': 1, 'throughTiming': 2, 'external155MHz': 4.
     sonetMediumExtTable 1.3.6.1.4.1.5504.5.9.2 no-access
This is an extenion of the standard Sonet MIB (RFC 2558).
         sonetMediumExtEntry 1.3.6.1.4.1.5504.5.9.2.1 no-access
Each row is an extension to the sonetMediumTable for Zhone specific fields. This row is created when the augmented sonetMediumEntry is created.
             sonetMediumExtScrambleEnabled 1.3.6.1.4.1.5504.5.9.2.1.1 truthvalue read-write
This field describes the enabled status of the Sonet Scramble mode. If this field is true(1) then Scramble mode is enabled, if this field is false(2) scramble mode is disable.
             sonetMediumExtLineScrmEnabled 1.3.6.1.4.1.5504.5.9.2.1.2 truthvalue read-write
This field describes the enabled status of the Line level Sonet Scramble mode. If this field is true(1), then Scramble mode is enabled. If this field is false(2), scramble mode is disable.
     sonetTraps 1.3.6.1.4.1.5504.5.9.3
All Zhone Sonet traps will be defined under this object identity.
         sonetV2Traps 1.3.6.1.4.1.5504.5.9.3.0
This object identity adds a zero(0) for the next to last sub-identifier which should be used for new SNMPv2 Traps.
             sonetClockTransmitSourceChange 1.3.6.1.4.1.5504.5.9.3.0.1
A notification trap is sent when either sonetClockExternalRecovery or sonetClockTransmitSource is changed. The trap object is identified by the OID instance of sonetClockTransmitSource described in the OBJECTS clause.
             sonetSectionStatusChange 1.3.6.1.4.1.5504.5.9.3.0.2
A notification trap is sent when there is a change in the sonet SECTION status. Currenly the following are supported: NO-DEFECT = 1 LOS = 2 LOF = 4 The trap object is identified by the OID instance of sonetSectionCurrentStatus described in the OBJECTS clause.
             sonetLineStatusChange 1.3.6.1.4.1.5504.5.9.3.0.3
A notification trap is sent when there is a change in the sonet LINE status. Currenly the following are supported: NO-DEFECT = 1 AIS = 2 RDI = 4 The trap object is identified by the OID instance of sonetLineCurrentStatus described in the OBJECTS clause.
             sonetPathStatusChange 1.3.6.1.4.1.5504.5.9.3.0.4
A notification trap is sent when there is a change in the sonetPathCurrentStatus. Currenly the following are supported: 1 sonetPathNoDefect 2 sonetPathSTSLOP 4 sonetPathSTSAIS 8 sonetPathSTSRDI 16 sonetPathUnequipped 32 sonetPathSignalLabelMismatch The trap object is identified by the OID instance of sonetPathCurrentStatus described in the OBJECTS clause.
     zhoneSonetErrorStatsTable 1.3.6.1.4.1.5504.5.9.6 no-access
Description.
         zhoneSonetErrorStatsEntry 1.3.6.1.4.1.5504.5.9.6.1 no-access
Description.
             zhoneSonetErrorStatsIndex 1.3.6.1.4.1.5504.5.9.6.1.1 interfaceindex no-access
Description.
             zhoneSonetErrorStatsLineFebeCount 1.3.6.1.4.1.5504.5.9.6.1.2 integer32 read-only
Number of RLOP far-end block errors (FEBE).
             zhoneSonetErrorStatsPathFebeCount 1.3.6.1.4.1.5504.5.9.6.1.3 integer32 read-only
Number of RPOP far-end block errors (FEBE).
             zhoneSonetErrorStatsLineBipCount 1.3.6.1.4.1.5504.5.9.6.1.4 integer32 read-only
Number of Receive Line Overhead Processor (RLOP) BIP-8 errors. The RLOP is responsible for line-level alarms and for monitoring performance.
             zhoneSonetErrorStatsSectionBipCount 1.3.6.1.4.1.5504.5.9.6.1.5 integer32 read-only
Number of Receive Section Overhead Processor (RSOP) bit-interleaved parity (BIP)-8 errors. The RSOP synchronizes and descrambles frames and provides section-level alarms and performance monitoring.
             zhoneSonetErrorStatsPathBipCount 1.3.6.1.4.1.5504.5.9.6.1.6 integer32 read-only
Number of Receive Path Overhead Processor (RPOP) BIP-8 errors. The RSOP interprets pointers and extracts path overhead and the synchronous payload envelope. It is also responsible for path-level alarms and for monitoring performance.
             zhoneSonetErrorStatsOofCount 1.3.6.1.4.1.5504.5.9.6.1.7 integer32 read-only
Near end is out of frame. False indicates that the line is up and in frame.
             zhoneSonetErrorStatsRxCellCount 1.3.6.1.4.1.5504.5.9.6.1.8 integer32 read-only
Receive ATM Cell Processor (RACP) receive cell count.
             zhoneSonetErrorStatsTxCellCount 1.3.6.1.4.1.5504.5.9.6.1.9 integer32 read-only
Transmit ATM Cell Processor (TACP) transmit cell count.
             zhoneSonetErrorStatsHecCorrectedCount 1.3.6.1.4.1.5504.5.9.6.1.10 integer32 read-only
Number of corrected HEC cells.
             zhoneSonetErrorStatsHecUncorrectedCount 1.3.6.1.4.1.5504.5.9.6.1.11 integer32 read-only
Number of uncorrected dropped HEC cells.
             zhoneSonetErrorStatsCellFifoOverflowCount 1.3.6.1.4.1.5504.5.9.6.1.12 integer32 read-only
Number of cells dropped because of first in, first out (FIFO) overflow.
             zhoneSonetErrorStatsLocdCount 1.3.6.1.4.1.5504.5.9.6.1.13 integer32 read-only
Loss of cell delineation.
 phySonet 1.3.6.1.4.1.5504.6.16
SONET physical MIB to configure and monitor SONET physical attributes.