ZHNSYSTEM: View SNMP OID List / Download MIB

VENDOR: ZHONE TECHNOLOGIES


 Home MIB: ZHNSYSTEM
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 zhnSystem 1.3.6.1.4.1.5504.2.5.2
This file defines the private Enterprise MIB extensions that define system related objects. ============================================================== == == == Copyright (C) 2008-2012 Zhone Technologies, Inc. == == == ==============================================================
     zhnSystemObjects 1.3.6.1.4.1.5504.2.5.2.1
         zhnSystemGeneralObjects 1.3.6.1.4.1.5504.2.5.2.1.1
             modelNumber 1.3.6.1.4.1.5504.2.5.2.1.1.1 displaystring read-only
model no. of the device
             macBaseAddress 1.3.6.1.4.1.5504.2.5.2.1.1.2 macaddress read-only
First MAC Address in series
             numberOfMacAddresses 1.3.6.1.4.1.5504.2.5.2.1.1.3 unsigned32 read-only
Number of MAC Address sequentially defined in the Unit starting at the MAC Base Address.
             wifiNetworkType 1.3.6.1.4.1.5504.2.5.2.1.1.4 wfnt read-write
Defines the Network Type or Mode of the Unit, i.e. Mesh or Base Station
             powerSupplyType 1.3.6.1.4.1.5504.2.5.2.1.1.5 upt read-only
Type of Power Supply that the unit is using
             locationLatitude 1.3.6.1.4.1.5504.2.5.2.1.1.6 displaystring read-write
The latitude of the unit's location represented in degrees decimal. The format of the location's latitude is: [+ | -]ddd.dddddddd where + indicates north - indicates south d is a decimal digit (0 <= d <= 9) Valid range is -90 to +90 degrees.
             locationLongitude 1.3.6.1.4.1.5504.2.5.2.1.1.7 displaystring read-write
The longitude of the unit's location represented in degrees decimal. The format of the location's longitude is: [+ | -]ddd.dddddddd where + indicates east - indicates west d is a decimal digit (0 <= d <= 9) Valid range is -180 to +180 degrees.
             zhnSystemAction 1.3.6.1.4.1.5504.2.5.2.1.1.8 rowstatus read-write
Action parameter to handle the action on other scalars.
             zhnSysLocation 1.3.6.1.4.1.5504.2.5.2.1.1.9 displaystring read-write
System location. This object is synonomous with the MIB II system sysLocation object.
             zhnSysContact 1.3.6.1.4.1.5504.2.5.2.1.1.10 displaystring read-write
System contact. This object is synonomous with the MIB II system sysContact object.
             sysTransmitClockSource 1.3.6.1.4.1.5504.2.5.2.1.1.11 tcsi read-write
T1 Clock source for PWE device. Since both T1/E1 interfaces will be required to have the same source, this object will replace the dsx1TransmitClockSource object in the DS1-MIB. This object is not supported by ZNID devices.
             sysLocalTimingReference 1.3.6.1.4.1.5504.2.5.2.1.1.12 ltri read-write
Source of the sysTransmitClockSource when set to Local. This object is not supported by ZNID devices.
             sysSynchronizationMode 1.3.6.1.4.1.5504.2.5.2.1.1.13 csmi read-write
Determines the method of ensuring Service Clock synchronization between the Source and Remote PWE devices.
             sysSynchronousEthernet 1.3.6.1.4.1.5504.2.5.2.1.1.14 sei read-write
Determines whether or not to use the 25MHz clock derived from the Synchronous Ethernet Port. This object is not supported by ZNID devices.
             sysClockMode 1.3.6.1.4.1.5504.2.5.2.1.1.15 cmi read-write
Determines the mode for which the PWE chip will be initialized.
             sysCfgDBAction 1.3.6.1.4.1.5504.2.5.2.1.1.16 cda read-write
Perform an action on the configuration database.
             sysSoftwareReboot 1.3.6.1.4.1.5504.2.5.2.1.1.17 rbt read-write
Perform a software reboot.
             sysSystemClockSource 1.3.6.1.4.1.5504.2.5.2.1.1.18 scs read-write
Determines the system-level clock mode for ZNID devices. uplink - the system will recover its clock from the configured uplink (e.g. GPON, SPF1, SFP2, etc.). ds1 - the system will recover its clock from the configured sysDs1ClockSourcePort. ieee1588 - the system will recover clock from the on-board 1588 clock circuitry.
             sysEthernetTransmitClockSource 1.3.6.1.4.1.5504.2.5.2.1.1.19 etcs read-write
Determines the transmit clock source for all ethernet ports requiring a clock. internal - all ethernet ports will recover clock from the local oscillator. systemClock - all ethernet ports will recover clock from the sysSystemClockSource.
             sysDs1ClockSourcePort 1.3.6.1.4.1.5504.2.5.2.1.1.20 displaystring read-write
The interface name for the DS1 port providing transmit clock when the sysSystemClockSource is set to ds1.
             sysBootloaderVersion 1.3.6.1.4.1.5504.2.5.2.1.1.21 octet string read-only
System bootloader (CFE) firmware version.
             sysFirmwareVersion 1.3.6.1.4.1.5504.2.5.2.1.1.22 octet string read-only
The version of firmware the system is currently running.
             sysAltFirmwareVersion 1.3.6.1.4.1.5504.2.5.2.1.1.23 octet string read-only
The alternate firmware version currently stored in system flash.
             sysRestoreAltFirmwareVersion 1.3.6.1.4.1.5504.2.5.2.1.1.24 sysfirmwareaction read-write
This object can be used to restore the version of firmware to the alternate firmware version currently stored in flash.
             sysSnmpProvisioningLock 1.3.6.1.4.1.5504.2.5.2.1.1.25 truthvalue read-write
This object can be set by an SNMP client to indicate that system configuration is in progress. All other SNMP clients will be locked out while this is set to true. This lock will timeout after 30 seconds.
             sysSnmpProvisioningChange 1.3.6.1.4.1.5504.2.5.2.1.1.26 unsigned32 read-write
This object can be incremented by SNMP clients to indicate a sysCfgDBAction save has taken place.
         zhnSystemBoardObjects 1.3.6.1.4.1.5504.2.5.2.1.2
             numberOfBoards 1.3.6.1.4.1.5504.2.5.2.1.2.1 unsigned32 read-only
Number of boards in the Unit with Name, Part Number, Serial Number and Revision Number values
             boardDescriptorTable 1.3.6.1.4.1.5504.2.5.2.1.2.2 no-access
Table of boards: Name, Part Number, Serial Number and Revision Number values
                 boardDescriptorEntry 1.3.6.1.4.1.5504.2.5.2.1.2.2.1 no-access
Table of boards: Name, Part Number, Serial Number and Revision Number values
                     boardIndex 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.1 unsigned32 no-access
Board Index (Zero relative)
                     boardName 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.2 displaystring read-only
Name of the Board as created by the system
                     boardPartNumber 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.3 displaystring read-only
Part Number of the Board. Read from the board
                     boardSerialNumber 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.4 displaystring read-only
Serial Number of the Board. Read from the board
                     boardRevision 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.5 displaystring read-only
Revision Number of the Board. Read from the board
         zhnSystemPldObjects 1.3.6.1.4.1.5504.2.5.2.1.3
             numberOfPlds 1.3.6.1.4.1.5504.2.5.2.1.3.1 unsigned32 read-only
Number of PLDs in the Unit with Name and Version Number values
             pldDescriptorTable 1.3.6.1.4.1.5504.2.5.2.1.3.2 no-access
Table of boards: Name, Part Number, Serial Number and Revision Number values
                 pldDescriptorEntry 1.3.6.1.4.1.5504.2.5.2.1.3.2.1 no-access
Table of boards: Name, Part Number, Serial Number and Revision Number values
                     pldIndex 1.3.6.1.4.1.5504.2.5.2.1.3.2.1.1 unsigned32 no-access
PLD Index (Zero relative)
                     pldName 1.3.6.1.4.1.5504.2.5.2.1.3.2.1.2 displaystring read-only
Name of the PLD as created by the system
                     pldVersion 1.3.6.1.4.1.5504.2.5.2.1.3.2.1.3 displaystring read-only
PLD Software Version. Read from the PLD
         zhnSystemRadioObjects 1.3.6.1.4.1.5504.2.5.2.1.4
             numberOfRadios 1.3.6.1.4.1.5504.2.5.2.1.4.1 unsigned32 read-only
Number of Radios in the Unit
         zhnSystemEthernetLikeObjects 1.3.6.1.4.1.5504.2.5.2.1.5
             numberOfEthernetLikeInterfaces 1.3.6.1.4.1.5504.2.5.2.1.5.1 unsigned32 read-write
Number of Ethernet Like Interfaces with Name, Type and Subtype
             ethernetlikeInterfaceTable 1.3.6.1.4.1.5504.2.5.2.1.5.2 no-access
Table of ethernet-like Interfaces
                 ethernetlikeInterfaceEntry 1.3.6.1.4.1.5504.2.5.2.1.5.2.1 no-access
Table of ethernet-like interfaces having Name, type, subtype, number of ports, line power and number of pairs with power
                     etherIndex 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.1 unsigned32 no-access
Index of the Ethernet Like Interface (zero relative)
                     etherName 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.2 displaystring read-only
Name of the ethernet Like Interface as created by the system
                     etherType 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.3 eltype read-only
Type of Ethernet interface
                     etherSubtype 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.4 elsubtype read-only
Subtype of Ethernet interface
                     etherNumberOfPorts 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.5 unsigned32 read-only
Number of Ports on the Ethernet interface
                     etherLinePower 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.6 lpt read-only
Line Power Type on this Ethernet Interface
                     etherPowerPairs 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.7 integer32 read-only
Number of line Pairs providing power on the Ethernet interface
         zhnSystemTempSensorObjects 1.3.6.1.4.1.5504.2.5.2.1.6
             numberOfTemperatureSensors 1.3.6.1.4.1.5504.2.5.2.1.6.1 unsigned32 read-only
Number of Temperature Sensors in the Unit
             temperatureSensorTable 1.3.6.1.4.1.5504.2.5.2.1.6.2 no-access
Table of Temperature Sensors: Name, Maximum, and Minimum values
                 temperatureSensorEntry 1.3.6.1.4.1.5504.2.5.2.1.6.2.1 no-access
Table of Temperature Sensors: Name, Maximum, and Minimum values
                     temperatureSensorIndex 1.3.6.1.4.1.5504.2.5.2.1.6.2.1.1 unsigned32 no-access
Temperature Sensor Index (Zero relative)
                     temperatureSensorName 1.3.6.1.4.1.5504.2.5.2.1.6.2.1.2 displaystring read-only
Name of the ethernet Like Interface as created by the system
                     temperatureSensorMaximum 1.3.6.1.4.1.5504.2.5.2.1.6.2.1.3 displaystring read-only
Maximum Temperature Recorded
                     temperatureSensorMinimum 1.3.6.1.4.1.5504.2.5.2.1.6.2.1.4 displaystring read-only
Minimum Temperature Recorded
         zhnSystemSNMPObjects 1.3.6.1.4.1.5504.2.5.2.1.7
             numberOfCommunities 1.3.6.1.4.1.5504.2.5.2.1.7.1 unsigned32 read-only
Number of SNMP Communities configured in the Unit
             zhnCommunityTable 1.3.6.1.4.1.5504.2.5.2.1.7.2 no-access
This table is used to set the various configuration parameters for a particular community.
                 zhnCommunityTableEntry 1.3.6.1.4.1.5504.2.5.2.1.7.2.1 no-access
This object corresponds to an entry in the community table.
                     communityName 1.3.6.1.4.1.5504.2.5.2.1.7.2.1.1 displaystring no-access
This object corresponds to the SNMP community string.
                     communityType 1.3.6.1.4.1.5504.2.5.2.1.7.2.1.2 integer read-write
The access type of the community string. The default value of this object should be read-only(1). Enumeration: 'readWrite': 2, 'readOnly': 1.
                     communityRowStatus 1.3.6.1.4.1.5504.2.5.2.1.7.2.1.3 rowstatus read-only
When written, this object can be used to createAndGo(4) or destroy(6) a row from the table. A rowStatus value of notInService(2) will also destroy a row. RowStatus values of active(1), notReady(3), and createAndWait(5) are ignored.
             zhnFixedCommunityTable 1.3.6.1.4.1.5504.2.5.2.1.7.3 no-access
This table is used to configure a read-only and a read-write community.
                 zhnFixedCommunityTableEntry 1.3.6.1.4.1.5504.2.5.2.1.7.3.1 no-access
This object corresponds to an entry in the fixed community table.
                     fixedCommunityName 1.3.6.1.4.1.5504.2.5.2.1.7.3.1.1 displaystring read-only
This object corresponds to the SNMP community string.
                     fixedCommunityType 1.3.6.1.4.1.5504.2.5.2.1.7.3.1.2 integer read-only
The access type of the community string. The default value of this object should be read-only(1). Enumeration: 'readWrite': 2, 'readOnly': 1.
                     fixedCommunityRowStatus 1.3.6.1.4.1.5504.2.5.2.1.7.3.1.3 rowstatus read-only
When written, this object is ignored. When read, a value of active(1) or notReady(3) will be returned.
         zhnSystemTrapObjects 1.3.6.1.4.1.5504.2.5.2.1.8
             numberOfTrapManagers 1.3.6.1.4.1.5504.2.5.2.1.8.1 unsigned32 read-only
Number of Trap Managers configured in the Unit
             zhnDefaultTrapCommunity 1.3.6.1.4.1.5504.2.5.2.1.8.2 displaystring read-write
This object corresponds to the default trap community string. The default trap community string will be used when a community name is not configured for a particular trap manager.
             zhnTrapTypeLinkUpDown 1.3.6.1.4.1.5504.2.5.2.1.8.3 integer read-write
Enable or disable all link up/down traps. Enumeration: 'enable': 1, 'disable': 2.
             zhnTrapTypeAuthFailure 1.3.6.1.4.1.5504.2.5.2.1.8.4 integer read-write
Enable or disable the generation of authorization failure traps. Enumeration: 'enable': 1, 'disable': 2.
             zhnTrapTypeConfigChange 1.3.6.1.4.1.5504.2.5.2.1.8.5 integer read-write
Enable or disable the generation of configuration change traps. This object is not supported by ZNID devices. Rather, the only mechanism to disable the generation of configuration change traps in a ZNID device is to disable the generation of all enterprise traps via the zhnTrapTypeEnterpise object. Enumeration: 'enable': 1, 'disable': 2.
             zhnTrapManagerInfoTable 1.3.6.1.4.1.5504.2.5.2.1.8.6 no-access
This table is used to set the trap destination address for a particular community.
                 zhnTrapManagerInfoTableEntry 1.3.6.1.4.1.5504.2.5.2.1.8.6.1 no-access
This object corresponds to an entry in the community trap address info table.
                     trapDestination 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.1 ipaddress no-access
The IP Address of the destination to which a trap must be sent.
                     trapCommunityName 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.2 displaystring read-write
This object corresponds to the trap community string. If not specified, the trapCommunityName will be set to the zhnDefaultTrapCommunity object.
                     trapVersion 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.3 integer read-write
The trap types automatically supported by net-snmp and enabled/disabled in snmpd.conf. If not specified, the trapVersion will be set the default value of v2c. Enumeration: 'v2c': 2, 'v1': 1.
                     trapPort 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.4 integer read-write
The udp/tcp port number to which a trap must be sent. If not specified, the trapPort will be set the default value of 162.
                     trapRowStatus 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.5 rowstatus read-only
When written, this object can be used to createAndGo(4) or destroy(6) a row from the table. A rowStatus value of notInService(2) will also destroy a row. RowStatus values of active(1), notReady(3), and createAndWait(5) are ignored.
             zhnTrapTypeColdStart 1.3.6.1.4.1.5504.2.5.2.1.8.7 integer read-write
Enable or disable the generation of coldstart traps. A coldstart trap is generated each time the device is restarted. Enumeration: 'enable': 1, 'disable': 2.
             zhnTrapTypeWarmStart 1.3.6.1.4.1.5504.2.5.2.1.8.8 integer read-write
Enable or disable the generation of warmstart traps. A warmstart trap is generated each time the device's SNMP agent is restarted. Enumeration: 'enable': 1, 'disable': 2.
             zhnTrapTypeEnterprise 1.3.6.1.4.1.5504.2.5.2.1.8.9 integer read-write
Enable or disable the generation of all enterprise traps. Enumeration: 'enable': 1, 'disable': 2.
         zhnSystemSyslogObjects 1.3.6.1.4.1.5504.2.5.2.1.9
             sysLogAdminStatus 1.3.6.1.4.1.5504.2.5.2.1.9.1 sysadminstatus read-write
Enable or disable the Syslog service.
             sysLogLocalLogLevel 1.3.6.1.4.1.5504.2.5.2.1.9.2 sysloglevel read-write
SysLog local log level options, per RFC 3164. All logged events with a severity at or greater than this level will be logged to the local log file. Note, the local log file is not persistent across system reboots.
             sysLogRemoteLogLevel 1.3.6.1.4.1.5504.2.5.2.1.9.3 sysloglevel read-write
SysLog remote log level options, per RFC 3164. All logged events with a severity at or greater that this level will be sent to a remote Syslog server if the remote server address is configured and a route exists to the remote server.
             sysLogDisplayLogLevel 1.3.6.1.4.1.5504.2.5.2.1.9.4 sysloglevel read-write
SysLog log level options, per RFC 3164 for the display of log messages via a web browser. All logged events with a severity level at or greater than this level will be displayed.
             sysLogMode 1.3.6.1.4.1.5504.2.5.2.1.9.5 syslogmode read-write
SysLog logging mode of operation: local(1), -- Log messages only to the local, non-persistent log file remote(2), -- Log messages only to a remote syslog server both(3), -- Log messages to both a local log file and a remote syslog server
             sysLogRemoteServerAddress 1.3.6.1.4.1.5504.2.5.2.1.9.6 ipaddress read-write
The IP address of the remote syslog server.
             sysLogRemoteServerPort 1.3.6.1.4.1.5504.2.5.2.1.9.7 unsigned32 read-write
The UDP port to use to transfer syslog messages to the remote syslog server.
         zhnSystemSNTPObjects 1.3.6.1.4.1.5504.2.5.2.1.10
               sntpAdminStatus 1.3.6.1.4.1.5504.2.5.2.1.10.1 sysadminstatus read-write
Enable or disable the SNTP client.
               sntpOperStatus 1.3.6.1.4.1.5504.2.5.2.1.10.2 sysadminstatus read-write
Current operational status of the SNTP client.
               sntpServer1 1.3.6.1.4.1.5504.2.5.2.1.10.3 octet string read-write
The domain name or IP address of the first SNTP server with which to synchronize the system time.
               sntpServer2 1.3.6.1.4.1.5504.2.5.2.1.10.4 octet string read-write
The domain name or IP address of the second SNTP server with which to synchronize the system time.
               sntpServer3 1.3.6.1.4.1.5504.2.5.2.1.10.5 octet string read-write
The domain name or IP address of the third SNTP server with which to synchronize the system time.
               sntpServer4 1.3.6.1.4.1.5504.2.5.2.1.10.6 octet string read-write
The domain name or IP address of the fourth SNTP server with which to synchronize the system time.
               sntpServer5 1.3.6.1.4.1.5504.2.5.2.1.10.7 octet string read-write
The domain name or IP address of the fifth SNTP server with which to synchronize the system time.
               sntpLocalTimeZone 1.3.6.1.4.1.5504.2.5.2.1.10.8 syssntptimezones read-write
Indicates the local time zone.
               sntpCurrentDateAndTime 1.3.6.1.4.1.5504.2.5.2.1.10.9 displaystring read-write
Indicates the current date and time.
         zhnSystemUserLoginObjects 1.3.6.1.4.1.5504.2.5.2.1.11
               adminUserName 1.3.6.1.4.1.5504.2.5.2.1.11.1 octet string read-only
The username required to login as the system administrator. This user has unrestricted access to change and view all configuration, status and test parameters.
               adminPassword 1.3.6.1.4.1.5504.2.5.2.1.11.2 octet string read-write
The password required to login as the system administrator. This field cannot contain a SPACE and is returned as a string of asterisks.
               supportUserName 1.3.6.1.4.1.5504.2.5.2.1.11.3 octet string read-only
The username required to login to support the system. This user has access to system parameters required to maintain the system and run diagnostic tests.
               supportPassword 1.3.6.1.4.1.5504.2.5.2.1.11.4 octet string read-write
The password required to login to support the system. This field cannot contain a SPACE and is returned as a string of asterisks.
               userUserName 1.3.6.1.4.1.5504.2.5.2.1.11.5 octet string read-only
The username required to login as a general user of the system. This user can view configuration settings and statistics, as well as, update the system's software.
               userPassword 1.3.6.1.4.1.5504.2.5.2.1.11.6 octet string read-write
The password required to login as a general user of the system. field cannot contain a SPACE and is returned as a string of asterisks.
         zhnSystemPowerSheddingObjects 1.3.6.1.4.1.5504.2.5.2.1.12
               powerSheddingAdminStatus 1.3.6.1.4.1.5504.2.5.2.1.12.1 sysadminstatus read-only
Configuration of parameters for the power-shedding feature. The power-shedding objects are only supported by systems that include on-board power-management circuitry. When the system detects that it is running on battery power, it has the option to shut down all support (excluding the voice over IP telephone service).The power-shedding administrative state will enable or disable the power-shedding feature.
               powerSheddingShutdownDelay 1.3.6.1.4.1.5504.2.5.2.1.12.2 unsigned32 read-only
The shutdown delay is the time delay, in minutes, after AC power is lost, before shutting down non-voice services.
               powerSheddingRestoreDelay 1.3.6.1.4.1.5504.2.5.2.1.12.3 unsigned32 read-only
The restore delay is the time delay, in minutes, after AC power is restored before switching on the services that were shut down due to the power loss.
         zhnSystemFirewallObjects 1.3.6.1.4.1.5504.2.5.2.1.13
               sysFirewallEnable 1.3.6.1.4.1.5504.2.5.2.1.13.1 truthvalue read-write
Enables or disables the firewall feature for the entire system.
               sysFirewallTcpSynCookies 1.3.6.1.4.1.5504.2.5.2.1.13.2 truthvalue read-only
Enables or disables the TCP SYNCookie protection against SYN flooding denial-of-service attack.
         zhnSystemDNSClientObjects 1.3.6.1.4.1.5504.2.5.2.1.14
               sysDNSAddressingType 1.3.6.1.4.1.5504.2.5.2.1.14.1 ipinterfaceaddressingtypevalues read-write
Type of IP interface addressing method used to reach the DNS.
               sysDNSDHCPSource 1.3.6.1.4.1.5504.2.5.2.1.14.2 octet string read-write
Name of the interface used by the DHCP Client to obtain DNS information.
               sysDNSPrimaryIPAddress 1.3.6.1.4.1.5504.2.5.2.1.14.3 ipaddress read-write
Primary Address of DNS when the addressing type is set to Static.
               sysDNSSecondaryIPAddress 1.3.6.1.4.1.5504.2.5.2.1.14.4 ipaddress read-write
Secondary Address of DNS when the addressing type is set to Static.
         zhnSystemDNSProxyObjects 1.3.6.1.4.1.5504.2.5.2.1.15
               zhnDnsProxyHostMaxHostEntries 1.3.6.1.4.1.5504.2.5.2.1.15.1 unsigned32 read-write
The maximum number of host entries in the DnsProxyHostObjectTable.
               zhnDnsProxyHostTable 1.3.6.1.4.1.5504.2.5.2.1.15.2 no-access
This table is used to configure a DNS Proxy Host entry.
                   zhnDnsProxyHostEntry 1.3.6.1.4.1.5504.2.5.2.1.15.2.1 no-access
This object corresponds to an entry in the DNS Proxy Host table.
                       dnsProxyHostIndex 1.3.6.1.4.1.5504.2.5.2.1.15.2.1.1 unsigned32 no-access
Index into the DNS Proxy Host table
                       dnsProxyHostIPAddress 1.3.6.1.4.1.5504.2.5.2.1.15.2.1.2 ipaddress read-write
The local proxy host IP address.
                       dnsProxyHostName 1.3.6.1.4.1.5504.2.5.2.1.15.2.1.3 octet string read-write
The domain name assigned to the host IP address.
                       dnsProxyRowStatus 1.3.6.1.4.1.5504.2.5.2.1.15.2.1.4 zhonerowstatus read-only
Create or destroy a DNS Proxy Host. Upon creation, the dnsProxyHostIPAddress must be provided.
         zhnSystemWanBackupObjects 1.3.6.1.4.1.5504.2.5.2.1.16
               failoverTimer 1.3.6.1.4.1.5504.2.5.2.1.16.1 unsigned32 read-write
The WAN Failover Timer is used to determine how long (in seconds) the Fiber uplink interface must be operationally DOWN before a USB Cellular WAN Backup connection will be initiated. The Default value is 0 seconds, which DISABLES this feature. The recommended value to enable this feature is 60 seconds.
               restoralTimer 1.3.6.1.4.1.5504.2.5.2.1.16.2 unsigned32 read-write
The WAN Restoral Timer is used to determine how long (in seconds) the Fiber uplink interface must remain in an operational UP condition before the Cellular Backup connection will be terminated and the traffic that was being forwarded out the USB interface is forwarded to the 5xx GEM instead. The default value is 60 seconds.
               backupDataVlan 1.3.6.1.4.1.5504.2.5.2.1.16.3 unsigned32 read-write
This is the Internet Access VLAN (GEM 5xx), which is the only service that can be backed up using the USB Cellular modem.
               cellularPinNumber 1.3.6.1.4.1.5504.2.5.2.1.16.4 octet string read-write
A 4 digit PIN code used to unlock the SIM card. For GPRS/UMTS networks, *99# is typically used. For CDMA/EVDO networks, #777 is typically used.
               cellularDataNumber 1.3.6.1.4.1.5504.2.5.2.1.16.5 octet string read-write
This is the number that the USB modem will dial to establish a cellular a cellular data connection. For GPRS/UMTS networks, *99# is typically used. For CDMA/EVDO networks, #777 is typically used.
               atInitCommands 1.3.6.1.4.1.5504.2.5.2.1.16.6 octet string read-write
AT initialization command strings, if needed.
               accessPointName 1.3.6.1.4.1.5504.2.5.2.1.16.7 octet string read-write
The Access Point Name (APN) for connections to the GPRS/UMTS network. This should be provided by the ISP. In North America, 3G cellular carriers do not require an APN.
               chapPapUsername 1.3.6.1.4.1.5504.2.5.2.1.16.8 octet string read-write
Required for CHAP or PAP authentication. This configuration item should be left blank if CHAP or PAP is not used.
               chapPapPassword 1.3.6.1.4.1.5504.2.5.2.1.16.9 octet string read-write
Required for CHAP or PAP authentication. This configuration item should be left blank if CHAP or PAP is not used.
               connectionTimeout 1.3.6.1.4.1.5504.2.5.2.1.16.10 unsigned32 read-write
Specifies the duration of inactivity in seconds before the cellular data call will automatically terminate. A new call will be initiated automatically when a packet must be sent upstream on the designated VLAN if the WAN uplink is still Operationally Down. A value of 0 will DISABLE the Connection Timeout feature.
               backupIpAddressMode 1.3.6.1.4.1.5504.2.5.2.1.16.11 basicaddressingtypevalues read-write
The WAN IP Address, Default Gateway IP Address, Subnet Mask and DNS Server IP Address must all be defined for the USB Cellular Backup connection. When IP Address Mode is set to DHCP, a DHCP Request will be sent upstream after the Cellular Data Connection has been established to acquire this information dynamically. When the WAN Backup IP Addess Mode is set to Static, this information ust be statically configured.
               backupIpAddress 1.3.6.1.4.1.5504.2.5.2.1.16.12 ipaddress read-write
The IP Address to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
               backupDefaultGateway 1.3.6.1.4.1.5504.2.5.2.1.16.13 ipaddress read-write
The IP Address of the Default Gateway to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
               backupSubnetMask 1.3.6.1.4.1.5504.2.5.2.1.16.14 ipaddress read-write
The Subnet Mask to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
               backupPrimaryDns 1.3.6.1.4.1.5504.2.5.2.1.16.15 ipaddress read-write
The IP Address of the Primary DNS Server to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
               backupSecondaryDns 1.3.6.1.4.1.5504.2.5.2.1.16.16 ipaddress read-write
The IP Address of the Secondary DNS Server to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
         zhnSystemTr69cObjects 1.3.6.1.4.1.5504.2.5.2.1.17
               sysTr69cConfigObjects 1.3.6.1.4.1.5504.2.5.2.1.17.1
                   sysTr69cConfigLoggingSOAP 1.3.6.1.4.1.5504.2.5.2.1.17.1.1 truthvalue read-write
Enable or disable showing SOAP messages on serial console and local TR69 Client log file.
                   sysTr69cConfigConnectionRequestAuthentication 1.3.6.1.4.1.5504.2.5.2.1.17.1.2 truthvalue read-write
Enable or disable connection request authentication.
               sysTr69cServerObjects 1.3.6.1.4.1.5504.2.5.2.1.17.2
                   sysTr69cServerURL 1.3.6.1.4.1.5504.2.5.2.1.17.2.1 octet string read-write
URL for the CPE to connect to the ACS using the CPE WAN Management Protocol. This parameter MUST be in the form of a valid HTTP or HTTPS URL. The host portion of this URL is used by the CPE for server-side certificate authentication when using SSL or TLS.
                   sysTr69cServerLastConnectedURL 1.3.6.1.4.1.5504.2.5.2.1.17.2.2 octet string read-only
This value records the last URL which connected successfully to the TR69 client.
                   sysTr69cServerUsername 1.3.6.1.4.1.5504.2.5.2.1.17.2.3 octet string read-write
Username used to authenticate the CPE when making a connection to the ACS using the CPE WAN Management Protocol. This username is used only for HTTP-based authentication of the CPE.
                   sysTr69cServerPassword 1.3.6.1.4.1.5504.2.5.2.1.17.2.4 octet string read-write
Password used to authenticate the CPE when making a connection to the ACS using the CPE WAN Management Protocol. This username is used only for HTTP-based authentication of the CPE. When read by an ACS, this parameter returns an empty string, regardless of the value.
                   sysTr69cServerPeriodicInformEnable 1.3.6.1.4.1.5504.2.5.2.1.17.2.5 truthvalue read-write
When set to TRUE, the CPE will periodically send CPE information to the TR69 Server using the Inform method calls.
                   sysTr69cServerPeriodicInformInterval 1.3.6.1.4.1.5504.2.5.2.1.17.2.6 unsigned32 read-write
The duration in seconds of the interval for which the CPE MUST attempt to connect with the ACS and call the Inform method if PeriodicInform-Enable is true.
                   sysTr69cServerParameterKey 1.3.6.1.4.1.5504.2.5.2.1.17.2.7 octet string read-only
ParameterKey provides the ACS a reliable and extensible means to track changes made by the ACS. The value of ParameterKey MUST be equal to the value of the ParameterKey argument from the most recent successful SetParameterValues, AddObject, or DeleteObject method call from the ACS. The CPE MUST set ParameterKey to the value specified in the corresponding method arguments if and only if the method completes successfully and no fault response is generated. If a method call does not complete successfully implying that the changes requested in the method did not take effect, the value of ParameterKey MUST NOT be modified. The CPE MUST only modify the value of ParameterKey as a result of SetParameterValues, AddObject, DeleteObject, or due to a factory reset. On factory reset, the value of ParameterKey MUST be set to empty.
                   sysTr69cServerBoundIfName 1.3.6.1.4.1.5504.2.5.2.1.17.2.8 octet string read-write
Name of the WAN interface that the TR69 client should use when establishing communications with the ACS.
                   sysTr69cServerConnectionRequestURL 1.3.6.1.4.1.5504.2.5.2.1.17.2.9 octet string read-only
HTTP URL for an ACS to make a Connection Request notification to the CPE. In the form: http://host:port/path. The host portion of the URL MAY be the IP address for the management interface of the CPE in lieu of a host name.
                   sysTr69cServerConnectionRequestUsername 1.3.6.1.4.1.5504.2.5.2.1.17.2.10 octet string read-write
Username used to authenticate an ACS making a Connection Request to the CPE.
                   sysTr69cServerConnectionRequestPassword 1.3.6.1.4.1.5504.2.5.2.1.17.2.11 octet string read-write
Password used to authenticate an ACS making a Connection Request to the CPE. When read by an ACS, this parameter returns an empty string, regardless of the actual value.
                   sysTr69cServerUpgradesManaged 1.3.6.1.4.1.5504.2.5.2.1.17.2.12 truthvalue read-write
Indicates whether or not the ACS will manage upgrades for the CPE. If true (1), the CPE SHOULD not use other means other than the ACS to seek out available upgrades. If false (0), the CPE MAY use other means for this purpose.
     zhnSystemConformance 1.3.6.1.4.1.5504.2.5.2.2
         zhnSystemGroups 1.3.6.1.4.1.5504.2.5.2.2.1
             zhnSystemActiveGroup 1.3.6.1.4.1.5504.2.5.2.2.1.1
A collection of System Information objects that are required for the device to be functional
             zhnSystemTablesItems 1.3.6.1.4.1.5504.2.5.2.2.1.2
The table items for the device that are filled in when the table is present
             zhnSystemConfigItems 1.3.6.1.4.1.5504.2.5.2.2.1.3
The collection of configurable scalar system objects.
             zhnSystemTrapItems 1.3.6.1.4.1.5504.2.5.2.2.1.4
The collection of SNMP trap objects.
             zhnSystemCommunityItems 1.3.6.1.4.1.5504.2.5.2.2.1.5
The collection of SNMP community objects.
             zhnSystemFixedCommunityItems 1.3.6.1.4.1.5504.2.5.2.2.1.6
The collection of pre-provisioned SNMP community objects.
             zhnSystemClockingItems 1.3.6.1.4.1.5504.2.5.2.2.1.7
The collection of system-wide clocking parameters only supported by ZNID devices.
             zhnSyslogConfigGroup 1.3.6.1.4.1.5504.2.5.2.2.1.8
The collection of system-wide logging parameters only supported by ZNID devices.
             zhnSntpConfigGroup 1.3.6.1.4.1.5504.2.5.2.2.1.9
The collection of SNTP server parameters only supported by ZNID devices.
             zhnUserLoginGroup 1.3.6.1.4.1.5504.2.5.2.2.1.10
The collection of User login parameters only supported by ZNID devices.
             zhnPowerSheddingGroup 1.3.6.1.4.1.5504.2.5.2.2.1.11
The collection of configurable power-shedding parameters only supported by ZNID devices.
             zhnSystemFirewallGroup 1.3.6.1.4.1.5504.2.5.2.2.1.12
The collection of system firewall parameters only supported by ZNID devices.
             zhnSystemDNSClientGroup 1.3.6.1.4.1.5504.2.5.2.2.1.13
The collection of system DNS Client parameters only supported by ZNID devices.
             zhnSystemDNSProxyHostGroup 1.3.6.1.4.1.5504.2.5.2.2.1.14
The collection of system DNS Proxy Host parameters only supported by ZNID devices.
             zhnSystemWanBackupGroup 1.3.6.1.4.1.5504.2.5.2.2.1.15
The collection of system WAN Backup parameters only supported by ZNID devices.
             zhnSystemTr69cGroup 1.3.6.1.4.1.5504.2.5.2.2.1.16
The collection of system TR69 Client parameters only supported by ZNID devices.
         zhnSystemCompliances 1.3.6.1.4.1.5504.2.5.2.2.2
             zhnSystemCompliance 1.3.6.1.4.1.5504.2.5.2.2.2.1
The Compliance statement for SNMP entities which manage the display of Zhone System Information