Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 xfRadioLinkPtpRadioMIB 1.3.6.1.4.1.193.81.3.4.3
This MIB defines objects for point-to-point Radio Link RAUs.
     xfRadioLinkPtpRadioObjects 1.3.6.1.4.1.193.81.3.4.3.1
         xfRAUTable 1.3.6.1.4.1.193.81.3.4.3.1.1 no-access
Table for Radiolink point-to-point radios managed objects. Table indexed with entPhysicalIndex.
             xfRAUEntry 1.3.6.1.4.1.193.81.3.4.3.1.1.1 no-access
An entry in xfRadioTable.
                 xfRAUAlarmStatus 1.3.6.1.4.1.193.81.3.4.3.1.1.1.1 bits read-only
This object shows the alarm status of the radio unit. atpcCability - The terminal is configured for ATPC, but the radio does not support ATPC. This alarm is activated only if ATPC is turned on (any direction). sdcHwErrorMain - Received RF input signal level for Main path (of SDC TRX) has dropped below the threshold for the receiver. sdcHwErrorDiv - Received RF input signal level for Diversity path (of SDC TRX) has dropped below the threshold for the receiver. sdcDadeCalMismatch - A TRX is connected and its Serial Number doesn't match with the serial number stored into MO xfTRXSdcSerialNumber. insufficientResourceRauXpic - Connected RAU is missing capabilities for XPIC. companionRauMismatch - Connected RAU does not match with the companion one, either in 1+1 RLP or XPIC. Bits: 'insufficientResourceRauXpic2': 17, 'sdcHwErrorDiv2': 11, 'sdcHwErrorMain2': 8, 'sdcHwErrorMain1': 7, 'sdcHwErrorMain0': 6, 'insufficientResourceRauXpic1': 16, 'sdcHwErrorDiv1': 10, 'atpcCapability1': 1, 'atpcCapability0': 0, 'atpcCapability2': 2, 'companionRauMismatch1': 19, 'sdcHwErrorDiv0': 9, 'companionRauMismatch2': 20, 'insufficientResourceRauXpic0': 15, 'sdcDadeCalMismatch2': 14, 'sdcDadeCalMismatch1': 13, 'sdcDadeCalMismatch0': 12, 'configurationInvalid0': 3, 'configurationInvalid1': 4, 'configurationInvalid2': 5, 'companionRauMismatch0': 18.
                 xfRAURfLoopAvailable 1.3.6.1.4.1.193.81.3.4.3.1.1.1.2 raurfloopavailable read-only
This object inidicates if RF loop is available in radio unit.
                 xfRAUAtpcCapability 1.3.6.1.4.1.193.81.3.4.3.1.1.1.3 rauatpccapability read-only
This object indicates if the radio unit supports ATPC or not.
                 xfRAULocalCtrlCapability 1.3.6.1.4.1.193.81.3.4.3.1.1.1.4 integer read-only
This object indicates if the radio unit supports local transmit power control or not. Enumeration: 'other': 1, 'supportsLocalControl': 3, 'noLocalControlSupport': 2.
                 xfRAUModCapability 1.3.6.1.4.1.193.81.3.4.3.1.1.1.5 raumodcapability read-only
This object shows the modulation methods supported by the radio unit.
                 xfRAUFrequencyband 1.3.6.1.4.1.193.81.3.4.3.1.1.1.6 unsigned32 read-only
This object shows the frequency band for the radio unit.
                 xfRAUSubBand 1.3.6.1.4.1.193.81.3.4.3.1.1.1.7 unsigned32 read-write
This object shows the sub band (Index) for the radio unit.
                 xfRAUTemperature 1.3.6.1.4.1.193.81.3.4.3.1.1.1.8 integer32 read-only
This object shows the temperature, in degree Celsius, inside the radio unit.
                 xfRAUProtectionPath 1.3.6.1.4.1.193.81.3.4.3.1.1.1.9 integer read-only
This object indicates what radio path the radio belongs to. Enumeration: 'rauRa2': 3, 'rauRa1': 2, 'other': 1.
                 xfRAURxCapability 1.3.6.1.4.1.193.81.3.4.3.1.1.1.10 integer read-only
This object indicates if the radio unit support RX configuration. Enumeration: 'rxSupport': 2, 'other': 1.
                 xfRAUNotes 1.3.6.1.4.1.193.81.3.4.3.1.1.1.11 octet string read-write
You can add information in this description field, for example polarization, antenna type or logging a site visit.
                 xfRauAtpcVersion 1.3.6.1.4.1.193.81.3.4.3.1.1.1.12 integer read-only
This object represents the RAU ATPC version. Enumeration: 'other': 1, 'version1': 2, 'version2': 3, 'version3': 4.
                 xfRauBoosterCapability 1.3.6.1.4.1.193.81.3.4.3.1.1.1.13 boostercapability read-only
This object represents the Booster capability for a link.
                 xfRauBoosterSelectedIndex 1.3.6.1.4.1.193.81.3.4.3.1.1.1.14 integer32 read-write
This object represents the Booster selected index for a link.
         xfRFIFTable 1.3.6.1.4.1.193.81.3.4.3.1.2 no-access
Table for Radiolink point-to-point radios RF IF managed objects. Table indexed with ifIndex.
             xfRFIFEntry 1.3.6.1.4.1.193.81.3.4.3.1.2.1 no-access
An entry in the xfRFIFTable.
                 xfRFBaseTxFrequency 1.3.6.1.4.1.193.81.3.4.3.1.2.1.1 unsigned32 read-only
This object shows the Tx frequency in KHz when frequency step number is 0.
                 xfRFBaseRxFrequency 1.3.6.1.4.1.193.81.3.4.3.1.2.1.2 unsigned32 read-only
This object shows the Rx frequency in KHz when frequency. step number is 0
                 xfRFStepSize 1.3.6.1.4.1.193.81.3.4.3.1.2.1.3 unsigned32 read-only
This object shows the frequency step size in KHz.
                 xfRFStepLimitLow 1.3.6.1.4.1.193.81.3.4.3.1.2.1.4 unsigned32 read-only
This object shows the lowest allowed frequency step number.
                 xfRFStepLimitHigh 1.3.6.1.4.1.193.81.3.4.3.1.2.1.5 unsigned32 read-only
This object shows the highest allowed frequency step number.
                 xfRFCurrentStepNumber 1.3.6.1.4.1.193.81.3.4.3.1.2.1.6 unsigned32 read-write
This object sets/shows the frequency step number. 0 = frequency not yet defined. For Classic RAUs, TX and RX frequencies can not be set individually. The span between them is always fixed and depends on different frequency and sub band. - To calculate step number for TX and RX, use the following formulas: New step number = (TX frequency - XfRAUBaseTxFrequency) / XfRAUStepSize New step number = (RX frequency - xfRAUBaseRxFrequency) / XfRAUStepSize - To calculate TX and RX frequencies, use the following formulas: TX frequency = XfRAUBaseTxFrequency + XfRAUCurrentStepNumber * XfRAUStepSize RX frequency = XfRAUBaseRxFrequency + XfRAUCurrentStepNumber * XfRAUStepSize For Agile RAUs, the TX and RX frequencies can be set individually. Above formulas are only valid for TX frequency. For RX frequency, xfRFCurrentStepNumberRx must be used. Default value: 0
                 xfRFTxOperStatus 1.3.6.1.4.1.193.81.3.4.3.1.2.1.7 rftxoperstatus read-only
This object shows the operational status of the transmitter.
                 xfRFTxAdminStatus 1.3.6.1.4.1.193.81.3.4.3.1.2.1.8 integer read-write
This object sets the desired status of the transmitter. Value other(1) not settable. Especially for far end: txOff(2), requests far end transmitter to be turned off. txOn(3), requests far end transmitter to be turned on. Default value: txOff(2) - near end. other(1) - far end. Enumeration: 'txOn': 3, 'other': 1, 'txOff': 2.
                 xfRFLoopEnable 1.3.6.1.4.1.193.81.3.4.3.1.2.1.9 integer read-write
This object manage RF loop. Default value: disable(3). Near end access: read-write. Far end access: no access. Enumeration: 'enable': 2, 'other': 1, 'disable': 3.
                 xfRFAlarms 1.3.6.1.4.1.193.81.3.4.3.1.2.1.10 bits read-only
This TC enumerates the alarms for RF interface. txFrequency - Transmitter frequency synthesizer loop is unlocked. rxFrequency - Receiver frequency synthesizer loop is unlocked. rfOutputLevel - Major degradation of transmitter output power is detected. rxAfc - The frequency of the received signal is outside the range of the Automatic Frequency Control in the RAU receiver. rfInputLevel - Receiver RF input signal level has dropped below the threshold for the receiver. rfInputThreshold - The RF input level has dropped below the xfRFInputAlarmThreshold. rfOutputLevelATPC - The transmitter output power has been continuously at 'Patpc,max' for too long. This can occur due to several reasons: * The operator has set 'Patpc,max' too low. * The hop attenuation has increased (steady-state). * The transmitter PA is v. * The LNA in Rx is deteriorating. Bits: 'tlts1Counter24h1': 52, 'txFrequency0': 0, 'rfInputLevel1': 13, 'rfInputLevel0': 12, 'rltmCounter15m0': 33, 'tlts1Counter24h0': 51, 'sdcRfInputLevelMain2': 23, 'sdcRfInputLevelMain1': 22, 'sdcRfInputLevelMain0': 21, 'rlts2Counter15m2': 32, 'rltmCounter24h1': 49, 'rlts2Counter15m0': 30, 'rlts2Counter15m1': 31, 'tltmCounter15m1': 40, 'tltmCounter15m0': 39, 'rfInputLevel2': 14, 'rxFrequency0': 3, 'rxFrequency1': 4, 'rxFrequency2': 5, 'remoteRfIfHighestSeverityAlarm2': 59, 'rltmCounter15m1': 34, 'remoteRfIfHighestSeverityAlarm0': 57, 'remoteRfIfHighestSeverityAlarm1': 58, 'rfOutputLevel2': 8, 'rfOutputLevel1': 7, 'rfOutputLevel0': 6, 'rlts1Counter24h0': 42, 'rlts1Counter24h1': 43, 'rlts1Counter24h2': 44, 'tlts1Counter24h2': 53, 'rfOutputLevelATPC2': 20, 'rfOutputLevelATPC1': 19, 'rfOutputLevelATPC0': 18, 'tlts1Counter15m2': 38, 'tltmCounter24h2': 56, 'tltmCounter24h0': 54, 'tltmCounter24h1': 55, 'tltmCounter15m2': 41, 'rltmCounter24h2': 50, 'rxAfc0': 9, 'rxAfc1': 10, 'rxAfc2': 11, 'txFrequency1': 1, 'tlts1Counter15m1': 37, 'rlts2Counter24h1': 46, 'rlts2Counter24h0': 45, 'rlts2Counter24h2': 47, 'rlts1Counter15m2': 29, 'rlts1Counter15m1': 28, 'rlts1Counter15m0': 27, 'ifcabledamaged0': 60, 'ifcabledamaged1': 61, 'ifcabledamaged2': 62, 'rfInputThreshold2': 17, 'tlts1Counter15m0': 36, 'rfInputThreshold0': 15, 'rfInputThreshold1': 16, 'sdcRfInputLevelDiv2': 26, 'txFrequency2': 2, 'sdcRfInputLevelDiv0': 24, 'sdcRfInputLevelDiv1': 25, 'rltmCounter24h0': 48, 'rltmCounter15m2': 35.
                 xfRFStatus 1.3.6.1.4.1.193.81.3.4.3.1.2.1.11 bits read-only
This object shows the RAU status. rfLoop - Warns if RF-loop is enabled on RAU txOff - Warns if TX is manually set to off Bits: 'rfLoop1': 1, 'rfLoop0': 0, 'rfLoop2': 2, 'txOff2': 5, 'txOff1': 4, 'txOff0': 3.
                 xfRFStepSizeRx 1.3.6.1.4.1.193.81.3.4.3.1.2.1.12 unsigned32 read-only
This object shows the Rx frequency step size in KHz.
                 xfRFStepLimitLowRx 1.3.6.1.4.1.193.81.3.4.3.1.2.1.13 unsigned32 read-only
This object shows the Rx lowest allowed frequency step number.
                 xfRFStepLimitHighRx 1.3.6.1.4.1.193.81.3.4.3.1.2.1.14 unsigned32 read-only
This object shows the Rx highest allowed frequency step number.
                 xfRFCurrentStepNumberRx 1.3.6.1.4.1.193.81.3.4.3.1.2.1.15 unsigned32 read-write
This object sets/shows the RX frequency step number for Agile RAUs. 0 = frequency not yet defined. - To calculate step number for RX, use the following formula: New step number Rx = (RX frequency - xfRAUBaseRxFrequency) / XfRAUStepSizeRx - To calculate RX frequency, use the following formula: RX frequency = XfRAUBaseRxFrequency + XfRAUCurrentStepNumberRx * XfRAUStepSizeRx Default value: 0
                 xfRFDuplexType 1.3.6.1.4.1.193.81.3.4.3.1.2.1.16 integer read-only
This object tells the duplex frequency mode for the RAU: - fixed: Tx frequency only can be set by operator, Rx frequency is automatically set on the basis of (fixed) RAU duplex frequency - variable: duplex frequency can be configured by operator Enumeration: 'variable': 3, 'other': 1, 'fixed': 2.
                 xfRFDuplexConfig 1.3.6.1.4.1.193.81.3.4.3.1.2.1.17 integer read-write
This object enables setting of duplex frequency for the RAU. It is always disabled(3) and can not be overwritten if xfRFDuplexType = fixed(2). Enumeration: 'disabled': 3, 'other': 1, 'enabled': 2.
                 xfRFDuplexDistance 1.3.6.1.4.1.193.81.3.4.3.1.2.1.18 integer32 read-write
This object is aimed to select the duplex distance for the RAU. It can only be set if xfRFDuplexConfig = enabled(2), so that: xfRFDuplexDistance = Tx Frequency - Rx Frequency Otherwise, it is automatically filled on the basis of Tx and Rx frequency settings, and can not be overwritten.
         xfRFPowerTable 1.3.6.1.4.1.193.81.3.4.3.1.3 no-access
Table for Radiolink point-to-point radios managed objects. Table indexed with ifIndex.
             xfRFPowerEntry 1.3.6.1.4.1.193.81.3.4.3.1.3.1 no-access
An entry in the xfRFPowerTable.
                 xfRFCurrentOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.3.1.1 integer32 read-only
This object shows the output power in dBm including attenuator.
                 xfRFRtpcMinOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.3.1.2 integer32 read-only
This object shows the minimum output power in dBm including attenuator. Value -100 indicate that RAU Tx on is not possible due to power supply limitations.
                 xfRFRtpcMaxOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.3.1.3 integer32 read-only
This object shows the maximum output power in dBm including attenuator. Value -100 indicate that RAU Tx on is not possible due to power supply limitations.
                 xfRFRtpcSelectedOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.3.1.4 integer32 read-write
This object set/shows the selected output power in dBm including attenuator. Value 254 indicates that the selected power is set to maximum. Default value: 254
                 xfRFAtpcMinOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.3.1.5 integer32 read-only
This object shows the minimum output power in dBm in ATPC. mode for radio contained in the radio terminal.
                 xfRFAtpcMaxOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.3.1.6 integer32 read-write
This object sets/shows the ATPC maximum output power in dBm for radio contained in the radio terminal. Value 254 indicates that the power is set to maximum. Default value: 254.
                 xfRFAtpcMinInputPowerFar 1.3.6.1.4.1.193.81.3.4.3.1.3.1.7 integer32 read-only
This object shows the ATPC minimum input target power level for far end radio.
                 xfRFAtpcSelectedInputPowerFar 1.3.6.1.4.1.193.81.3.4.3.1.3.1.8 integer32 read-write
This object sets/shows the ATPC selected input target level for far end radio. Default value: -30.
                 xfRFAttenuator 1.3.6.1.4.1.193.81.3.4.3.1.3.1.9 integer32 read-write
This object sets/shows the value in dBm for fixed attenuator mounted in antenna. Default value: 0.
                 xfRFCurrentInputPower 1.3.6.1.4.1.193.81.3.4.3.1.3.1.10 integer32 read-only
This object shows RF input level = value/10 dBm. Domain: [-20.0 .. -99.9 dBm].
                 xfRFMaxInputPowerLast7Days 1.3.6.1.4.1.193.81.3.4.3.1.3.1.11 integer32 read-only
This object shows maximum RF input level last 7 days. RF input level = value/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates invalid value.
                 xfRFMinInputPowerLast7Days 1.3.6.1.4.1.193.81.3.4.3.1.3.1.12 integer32 read-only
This object shows minimum RF input level last 7 days. RF input level = value/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates invalid value.
                 xfRFMaxInputPowerSinceReset 1.3.6.1.4.1.193.81.3.4.3.1.3.1.13 integer32 read-only
This object shows maximum RF input level since reset. RF input level = value/10 dBm. Domain: [-20.0 .. -99.9 dBm].
                 xfRFMinInputPowerSinceReset 1.3.6.1.4.1.193.81.3.4.3.1.3.1.14 integer32 read-only
This object shows minimum RF input level since reset. RF input level = value/10 dBm. Domain: [-20.0 .. -99.9 dBm].
                 xfRFInputPowerReset 1.3.6.1.4.1.193.81.3.4.3.1.3.1.15 integer read-write
This object reset the registers for the RF input level and All Time High level this seven days period and counters for the next seven days period of time Note. For protected rlMLE and rlXfMLE terminals this command will reset both Ra1 and Ra2 values. Near end access: read-write Far end access: read-write (Traffic Node only) Enumeration: 'inputPowerReset': 1.
                 xfRFInputAlarmThreshold 1.3.6.1.4.1.193.81.3.4.3.1.3.1.16 integer32 read-write
This object shows RF input level threshold. Default value: -93.
                 xfRFOutputPower4QAM 1.3.6.1.4.1.193.81.3.4.3.1.3.1.17 integer32 read-only
Output power for 4QAM.
                 xfRFOutputPower8QAM 1.3.6.1.4.1.193.81.3.4.3.1.3.1.18 integer32 read-only
Output power for 8QAM.
                 xfRFOutputPower16QAM 1.3.6.1.4.1.193.81.3.4.3.1.3.1.19 integer32 read-only
Output power for 16QAM.
                 xfRFOutputPower32QAM 1.3.6.1.4.1.193.81.3.4.3.1.3.1.20 integer32 read-only
Output power for 32QAM.
                 xfRFOutputPower64QAM 1.3.6.1.4.1.193.81.3.4.3.1.3.1.21 integer32 read-only
Output power for 64QAM.
                 xfRFOutputPower128QAM 1.3.6.1.4.1.193.81.3.4.3.1.3.1.22 integer32 read-only
Output power for 128QAM.
                 xfRFOutputPower256QAM 1.3.6.1.4.1.193.81.3.4.3.1.3.1.23 integer32 read-only
Output power for 256QAM.
                 xfRFOutputPower512QAM 1.3.6.1.4.1.193.81.3.4.3.1.3.1.24 integer32 read-only
Output power for 512QAM.
                 xfRFAtpcFallbackOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.3.1.25 integer32 read-write
This object sets maximum output power in dBm in ATPCFallback mode for radio contained in the radio terminal. Value = 254 indicates that the power is set to maximum. Default value: 254.
                 xfRFAtpcFallbackEnable 1.3.6.1.4.1.193.81.3.4.3.1.3.1.26 atpcfallbackenable read-write
Enable/disable ATPCFallback.
                 xfRFAtpcFallbackTimer 1.3.6.1.4.1.193.81.3.4.3.1.3.1.27 integer32 read-write
ATPC Fallback Timer specifies how long the output power can be at PATPC, MAX before ATPC fallback is triggered Default value: 15 min
                 xfRFOutputPower1024QAM 1.3.6.1.4.1.193.81.3.4.3.1.3.1.28 integer32 read-only
Output power for 1024QAM.
                 xfRFMaxOutputPowerNotLimited 1.3.6.1.4.1.193.81.3.4.3.1.3.1.29 integer32 read-only
Max output power in dBm including attenuator that the RAU can give if it is not power supply limited.
                 xfRFMaxOutputPowerNotPossible 1.3.6.1.4.1.193.81.3.4.3.1.3.1.30 integer read-only
unknown(0) isPossible(1) Max output power is possible due to power supply limitations isNotPossible(2) Max output power is not possible due to power supply limitations Enumeration: 'unknown': 0, 'isNotPossible': 2, 'isPossible': 1.
                 xfRFCurrentInputPowerSdcMain 1.3.6.1.4.1.193.81.3.4.3.1.3.1.31 integer32 read-only
This object shows RF input level for SDC Main path = value/10 dBm. Domain: [-20.0 .. -99.9 dBm]. 0 (zero) indicates invalid value (e.g. SDC not available).
                 xfRFCurrentInputPowerSdcDiv 1.3.6.1.4.1.193.81.3.4.3.1.3.1.32 integer32 read-only
This object shows RF input level for SDC Diversity path = value/10 dBm. Domain: [-20.0 .. -99.9 dBm]. 0 (zero) indicates invalid value (e.g. SDC not available).
                 xfRFMeanInputPower1m 1.3.6.1.4.1.193.81.3.4.3.1.3.1.33 integer32 read-only
This object shows RF input mean level for last minute. RF input level = value/10 dBm. Domain: [-99.9 ... -20.0 dBm] 0 (zero) indicates invalid value.
                 xfRFMaxOutputPowerLast7Days 1.3.6.1.4.1.193.81.3.4.3.1.3.1.34 integer32 read-only
This object shows maximum RF output level last 7 days. RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
                 xfRFMinOutputPowerLast7Days 1.3.6.1.4.1.193.81.3.4.3.1.3.1.35 integer32 read-only
This object shows minimum RF output level last 7 days. RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
                 xfRFMaxOutputPowerSinceReset 1.3.6.1.4.1.193.81.3.4.3.1.3.1.36 integer32 read-only
This object shows maximum RF output level since reset RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
                 xfRFMinOutputPowerSinceReset 1.3.6.1.4.1.193.81.3.4.3.1.3.1.37 integer32 read-only
This object shows minimum RF output level since reset RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
                 xfRFMaxMSELast7Days 1.3.6.1.4.1.193.81.3.4.3.1.3.1.38 integer32 read-only
Indicate Max MSE level last 7 days. Input level = value/10 dB. Domain: [-100.0 ... 100.0 dB] 2000 indicates invalid value.
                 xfRFMinMSELast7Days 1.3.6.1.4.1.193.81.3.4.3.1.3.1.39 integer32 read-only
Indicate Min MSE level last 7 days. Input level = value/10 dB. Domain: [-100.0 ... 100.0 dB] 2000 indicates invalid value.
                 xfRFMaxXPILast7Days 1.3.6.1.4.1.193.81.3.4.3.1.3.1.40 integer32 read-only
Indicate Max Cross-Polar Interference (XPI) level last 7 days. Input level = value/10 dB. Domain: [-100.0 ... 100.0 dB] 2000 indicates invalid value.
                 xfRFMinXPILast7Days 1.3.6.1.4.1.193.81.3.4.3.1.3.1.41 integer32 read-only
Indicate Min Cross-Polar Interference (XPI) level last 7 days. Input level = value/10 dB. Domain: [-100.0 ... 100.0 dB] 2000 indicates invalid value.
                 xfRFOutputPowerReset 1.3.6.1.4.1.193.81.3.4.3.1.3.1.42 integer read-write
This object reset the registers for the RF output level and All Time High level this seven days period and counters for the next seven days period of time. Enumeration: 'outputPowerReset': 1.
                 xfRFBoosterGain 1.3.6.1.4.1.193.81.3.4.3.1.3.1.43 integer32 read-only
Value of the Gain of the Booster
                 xfRFBoosterMaxInputPower 1.3.6.1.4.1.193.81.3.4.3.1.3.1.44 integer32 read-only
Value of the Max Input Power admitted towards the Booster
                 xfRFBoosterCapability 1.3.6.1.4.1.193.81.3.4.3.1.3.1.45 boostercapability read-only
Value of Booster capability according to the system
                 xfRFBoosterProductNumber 1.3.6.1.4.1.193.81.3.4.3.1.3.1.46 displaystring read-write
Product Number of the Booster connected to the specific RF IF
                 xfRFBoosterHWRevision 1.3.6.1.4.1.193.81.3.4.3.1.3.1.47 displaystring read-write
HW Revision of the Booster connected to the specific RF IF
         xfRAUCapabilityTable 1.3.6.1.4.1.193.81.3.4.3.1.4 no-access
Table for RAU capability information. Table indexed with entPhysicalIndex and xfTermRowIndex.
             xfRAUCapabilityEntry 1.3.6.1.4.1.193.81.3.4.3.1.4.1 no-access
An entry in xfRAUCapabilityTable.
                 xfRAUChannelSpacing 1.3.6.1.4.1.193.81.3.4.3.1.4.1.1 rauchannelspacingcapability read-only
Channel spacing. ETSI: 3.5, 7, 14, 28, 40, 56 MHz ANSI: 10, 20, 30, 40, 50 MHz
                 xfRAUChannelModulation 1.3.6.1.4.1.193.81.3.4.3.1.4.1.2 raumodulation read-only
This object shows the modulation. Values: cqpsk(2) CQPSK qam16(3) 16-QAM qam128(4) 128-QAM qam32(5) 32-QAM qam64(6) 64-QAM qam4(7) 4-QAM qam8(8) 8-QAM qam256(9) 256-QAM qam512(10) 512-QAM qam1024(11) 1024-QAM
                 xfRAUSpectrumEfficiencyClass 1.3.6.1.4.1.193.81.3.4.3.1.4.1.3 rausec read-only
Spectrum Efficiency Class: other(1), unknown sec2(2), Spectrum eff. Class 2 sec3(3), Spectrum eff. Class 3 sec4L(4), Spectrum eff. Class 4L sec4H(5), Specturm eff. Class 4H sec5A(6), Spectrum eff. Class 5A sec5B(7), Spectrum eff. Class 5B sec6A(8), Spectrum eff. Class 6A sec6B(9) Spectrum eff. Class 6B
                 xfRAUCarrierMode 1.3.6.1.4.1.193.81.3.4.3.1.4.1.4 integer read-only
Radio carrier mode. Enumeration: 'mimoMultiCarrier': 3, 'singleCarrier': 1, 'xpicDualCarrier': 2.
         xfRAUSubBandTable 1.3.6.1.4.1.193.81.3.4.3.1.5 no-access
Table for RAU Sub-Band index capability. Table indexed with entPhysicalIndex and xfRAUSubBandIndex.
             xfRAUSubBandEntry 1.3.6.1.4.1.193.81.3.4.3.1.5.1 no-access
An entry in xfRAUSubBandTable.
                 xfRAUSubBandIndex 1.3.6.1.4.1.193.81.3.4.3.1.5.1.1 unsigned32 read-only
An index for the specific RAU Sub-Band available index range.
                 xfRAUSubBandRange 1.3.6.1.4.1.193.81.3.4.3.1.5.1.2 unsigned32 read-only
This object shows the RAU Sub-Band available index range [0..255].
         xfRFSpectrumDiagTable 1.3.6.1.4.1.193.81.3.4.3.1.6 no-access
Table for RF Spectrum Diagnostics control and status
             xfRFSpectrumDiagEntry 1.3.6.1.4.1.193.81.3.4.3.1.6.1 no-access
An entry in xfRFSpectrumDiagTable
                 xfRFSpectrumDiagAdminStatus 1.3.6.1.4.1.193.81.3.4.3.1.6.1.1 integer read-write
RF Spectrum Diagnostics Admin Status Enumeration: 'subBandScanStart': 3, 'other': 1, 'channelScanStart': 2, 'scanStop': 255.
                 xfRFSpectrumDiagOperStatus 1.3.6.1.4.1.193.81.3.4.3.1.6.1.2 integer read-only
RF Spectrum Diagnostics Oper Status Enumeration: 'channelScanOngoing': 2, 'channelScanFinished': 5, 'scanCanceled': 3, 'subBandScanFinished': 4, 'scanNotStarted': 0, 'subBandScanOngoing': 1.
                 xfRFSpectrumDiagChannelScanEstTime 1.3.6.1.4.1.193.81.3.4.3.1.6.1.3 unsigned32 read-only
Estimated time in seconds for scanning one Channel Spacing at current RX frequency
                 xfRFSpectrumDiagSubBandScanEstTime 1.3.6.1.4.1.193.81.3.4.3.1.6.1.4 unsigned32 read-only
Estimated time in seconds for scanning full Sub Band of connected RAU
                 xfRFSpectrumDiagScanDate 1.3.6.1.4.1.193.81.3.4.3.1.6.1.5 displaystring read-only
Date and time when scan (channel or sub-band) is completed, format: [YYYY]-[MM]-[DD]T[hh]:[mm]:[ss]
                 xfRFSpectrumDiagChannelSpacing 1.3.6.1.4.1.193.81.3.4.3.1.6.1.6 unsigned32 read-only
Channel width measured by Spectrum Diagnostics
                 xfRFSpectrumDiagCurrRxFrequency 1.3.6.1.4.1.193.81.3.4.3.1.6.1.7 unsigned32 read-only
Current value of Rx frequency
                 xfRFSpectrumDiagMinRxFrequency 1.3.6.1.4.1.193.81.3.4.3.1.6.1.8 unsigned32 read-only
Minimum sub-band Rx frequency (RAU lower edge)
                 xfRFSpectrumDiagMaxRxFrequency 1.3.6.1.4.1.193.81.3.4.3.1.6.1.9 unsigned32 read-only
Maximum sub-band Rx frequency (RAU upper edge)
                 xfRFSpectrumDiagIdxCompanion1 1.3.6.1.4.1.193.81.3.4.3.1.6.1.10 unsigned32 read-only
RF IF index for 1st companion carrier (0 if no companion)
                 xfRFSpectrumDiagIdxCompanion2 1.3.6.1.4.1.193.81.3.4.3.1.6.1.11 unsigned32 read-only
RF IF index for 2nd companion carrier (0 if no companion)
                 xfRFSpectrumDiagIdxCompanion3 1.3.6.1.4.1.193.81.3.4.3.1.6.1.12 unsigned32 read-only
RF IF index for 3rd companion carrier (0 if no companion)
                 xfRFSpectrumDiagProgress 1.3.6.1.4.1.193.81.3.4.3.1.6.1.13 unsigned32 read-only
Completed percentage of Spectrum Diagnostics scan
         xfRFSpectrumDiagResultTable 1.3.6.1.4.1.193.81.3.4.3.1.7 no-access
Table of Spectrum Diagnostics scan results
             xfRFSpectrumDiagResultEntry 1.3.6.1.4.1.193.81.3.4.3.1.7.1 no-access
An entry in xfRFSpectrumDiagResultTable
                 xfRFSpectrumDiagResultIndex 1.3.6.1.4.1.193.81.3.4.3.1.7.1.1 unsigned32 read-only
Spectrum Diagnostics Scan Result Index
                 xfRFSpectrumDiagResultRxFrequency 1.3.6.1.4.1.193.81.3.4.3.1.7.1.2 unsigned32 read-only
Spectrum Diagnostics Scan Result Rx frequency in kHz
                 xfRFSpectrumDiagResultRxPower 1.3.6.1.4.1.193.81.3.4.3.1.7.1.3 integer32 read-only
Spectrum Diagnostics Scan Result Rx Power value/10 dBm Domain: [-99.9 .. -20.0 dBm]
         xfRfIfPowerTable 1.3.6.1.4.1.193.81.3.4.3.1.8 no-access
Table for Radio Link RAU managed objects. Table indexed with ifIndex.
             xfRfIfPowerEntry 1.3.6.1.4.1.193.81.3.4.3.1.8.1 no-access
An entry in the xfRfIfPowerTable.
                 xfRfSelectedMinOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.8.1.1 rfoutputpower read-write
Minimum output power in dBm (selected by operator). Default value: 10 dBm.
                 xfRfSelectedMaxOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.8.1.2 rfoutputpower read-write
Maximum output power in dBm (selected by operator). Default value: 10 dBm.
                 xfRfCurrentOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.8.1.3 rfoutputpower read-only
Current output power in dBm. 255 indicates invalid value.
                 xfRfMinOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.8.1.4 rfoutputpower read-only
Minimum output power in dBm (provided by RAU). 255 indicates invalid value.
                 xfRfMaxOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.8.1.5 rfoutputpower read-only
Maximum output power in dBm (provided by RAU). 255 indicates invalid value.
                 xfRfAtpcTargetInputPowerFE 1.3.6.1.4.1.193.81.3.4.3.1.8.1.6 integer32 read-write
ATPC target input power on Far End side. Default value: -30.
                 xfRfCurrentInputPower 1.3.6.1.4.1.193.81.3.4.3.1.8.1.7 rfinputpower read-only
RF input level. Value is in 1/10 dBm. Domain: [-20.0 .. -99.9 dBm].
                 xfRfMaxInputPowerLast7Days 1.3.6.1.4.1.193.81.3.4.3.1.8.1.8 rfinputpower read-only
Maximum RF input level in the last 7 days. Value is in 1/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates an invalid value.
                 xfRfMinInputPowerLast7Days 1.3.6.1.4.1.193.81.3.4.3.1.8.1.9 rfinputpower read-only
Minimum RF input level in the last 7 days. Value is in 1/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates an invalid value.
                 xfRfMaxInputPowerSinceReset 1.3.6.1.4.1.193.81.3.4.3.1.8.1.10 rfinputpower read-only
Maximum RF input level since reset. Value is in 1/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates an invalid value.
                 xfRfMinInputPowerSinceReset 1.3.6.1.4.1.193.81.3.4.3.1.8.1.11 rfinputpower read-only
Minimum RF input level since reset. Value is in 1/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates an invalid value.
                 xfRfInputPowerReset 1.3.6.1.4.1.193.81.3.4.3.1.8.1.12 integer read-write
This object resets the registers for: - RF input power levels - input levels (i.e. RF power, MSE and XPI) in the next 7 days period of time. Enumeration: 'other': 1, 'inputPowerNoReset': 2, 'inputPowerReset': 3.
                 xfRfInputAlarmThreshold 1.3.6.1.4.1.193.81.3.4.3.1.8.1.13 integer32 read-write
RF input level threshold. Default value: -93.
                 xfRfOutputPower4QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.14 rfoutputpower read-only
Output power for 4QAM. 255 indicates invalid value.
                 xfRfOutputPower16QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.15 rfoutputpower read-only
Output power for 16QAM. 255 indicates invalid value.
                 xfRfOutputPower32QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.16 rfoutputpower read-only
Output power for 32QAM. 255 indicates invalid value.
                 xfRfOutputPower64QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.17 rfoutputpower read-only
Output power for 64QAM. 255 indicates invalid value.
                 xfRfOutputPower128QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.18 rfoutputpower read-only
Output power for 128QAM. 255 indicates invalid value.
                 xfRfOutputPower256QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.19 rfoutputpower read-only
Output power for 256QAM. 255 indicates invalid value.
                 xfRfOutputPower512QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.20 rfoutputpower read-only
Output power for 512QAM. 255 indicates invalid value.
                 xfRfOutputPower1024QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.21 rfoutputpower read-only
Output power for 1024QAM. 255 indicates invalid value.
                 xfRfOutputPower2048QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.22 rfoutputpower read-only
Output power for 2048QAM. 255 indicates invalid value.
                 xfRfOutputPower4096QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.23 rfoutputpower read-only
Output power for 4096QAM. 255 indicates invalid value.
                 xfRfMaxOutputPowerNotLimited 1.3.6.1.4.1.193.81.3.4.3.1.8.1.24 rfoutputpower read-only
Max output power in dBm that the RAU can give if it is not power supply limited. 255 indicates invalid value.
                 xfRfMaxOutputPowerPossible 1.3.6.1.4.1.193.81.3.4.3.1.8.1.25 integer read-only
possible(2): max output power is possible. notPossible(3): max output power is not possible, due to power supply limitations. Enumeration: 'notPossible': 3, 'other': 1, 'possible': 2.
                 xfRfMeanInputPower1m 1.3.6.1.4.1.193.81.3.4.3.1.8.1.26 integer32 read-only
This object shows RF input mean level for last minute. RF input level = value/10 dBm. Domain: [-99.9 ... -20.0 dBm] 0 (zero) indicates invalid value.
                 xfRfMaxOutputPowerLast7Days 1.3.6.1.4.1.193.81.3.4.3.1.8.1.27 integer32 read-only
This object shows maximum RF output level last 7 days. RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
                 xfRfMinOutputPowerLast7Days 1.3.6.1.4.1.193.81.3.4.3.1.8.1.28 integer32 read-only
This object shows minimum RF output level last 7 days. RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
                 xfRfMaxOutputPowerSinceReset 1.3.6.1.4.1.193.81.3.4.3.1.8.1.29 integer32 read-only
This object shows maximum RF output level since reset RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
                 xfRfMinOutputPowerSinceReset 1.3.6.1.4.1.193.81.3.4.3.1.8.1.30 integer32 read-only
This object shows minimum RF output level since reset RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
                 xfRfOutputPowerReset 1.3.6.1.4.1.193.81.3.4.3.1.8.1.31 integer read-write
This object reset the registers for the RF output level and All Time High level this seven days period and counters for the next seven days period of time. Enumeration: 'outputPowerNoReset': 2, 'other': 1, 'outputPowerReset': 3.
                 xfRfAvailableOutputPowerType 1.3.6.1.4.1.193.81.3.4.3.1.8.1.32 integer read-only
This object reports the output power capability of the RAU: - standardPower - highPower Enumeration: 'other': 1, 'highPower': 3, 'standardPower': 2.
                 xfRfSelectedOutputPowerType 1.3.6.1.4.1.193.81.3.4.3.1.8.1.33 integer read-write
This object allows setting the output power type: - standardPower - highPower default: standardPower(2) When the type is set to highPower(3) a HP license key is required. If the license key is not present the capacity is limited to Basic Capacity. The output power can be configured as 'normal' without any impact from the HP license key (present or not). When the mode is standardPower(2) the availableMaxOutputPower is limited to 'max power' - 4 dB per modulation. Enumeration: 'other': 1, 'highPower': 3, 'standardPower': 2.
                 xfRfTaps 1.3.6.1.4.1.193.81.3.4.3.1.8.1.34 integer read-write
This object allows setting the Traffic Aware Power Saving. Default: disabled(3) Enumeration: 'disabled': 3, 'notAvailable': 4, 'other': 1, 'enabled': 2.
                 xfRfCurrentInputPowerSdcMain 1.3.6.1.4.1.193.81.3.4.3.1.8.1.35 rfinputpower read-only
This object shows RF input level for SDC Main path = value/10 dBm. Domain: [-20.0 .. -99.9 dBm]. 0 (zero) indicates invalid value (e.g. SDC not available).
                 xfRfCurrentInputPowerSdcDiv 1.3.6.1.4.1.193.81.3.4.3.1.8.1.36 rfinputpower read-only
This object shows RF input level for SDC Diversity path = value/10 dBm. Domain: [-20.0 .. -99.9 dBm]. 0 (zero) indicates invalid value (e.g. SDC not available).
                 xfRfOutputPower8192QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.37 rfoutputpower read-only
Output power for 8192QAM. 255 indicates invalid value.
                 xfRfOutputPower16384QAM 1.3.6.1.4.1.193.81.3.4.3.1.8.1.38 rfoutputpower read-only
Output power for 16384QAM. 255 indicates invalid value.
                 xfRfAtpcFallbackOutputPower 1.3.6.1.4.1.193.81.3.4.3.1.8.1.39 rfoutputpower read-write
This object sets output power (in dBm) in ATPCFallback mode, for radio contained in the Carrier Termination. 255 indicates invalid value.
                 xfRfAtpcFallbackEnable 1.3.6.1.4.1.193.81.3.4.3.1.8.1.40 atpcfallbackenable read-write
Enable/disable ATPCFallback.
                 xfRfAtpcFallbackTimer 1.3.6.1.4.1.193.81.3.4.3.1.8.1.41 integer32 read-write
This object specifies how long the output power can be at (ATPC, MAX) before ATPC fallback is triggered. Default value: ETSI 15 min, ANSI 5 min.
         xfRFIFCableMonitoringTable 1.3.6.1.4.1.193.81.3.4.3.1.9 no-access
Table for Radiolink point-to-point radios RF IF Cable Monitoring managed objects. Table indexed with ifIndex.
             xfRFIFCableMonitoringEntry 1.3.6.1.4.1.193.81.3.4.3.1.9.1 no-access
An entry in the xfRFIFCableMonitoringTable.
                 xfRFIFCMStatus 1.3.6.1.4.1.193.81.3.4.3.1.9.1.1 integer read-write
This object manage IfCable Monitoring Status. Default value: disable(2). Near end access: read-write. Far end access: no access. Enumeration: 'enable': 3, 'other': 1, 'disable': 2.
                 xfRFOutlierAgc 1.3.6.1.4.1.193.81.3.4.3.1.9.1.2 integer read-write
This object manage IfCable Outlier Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access. Enumeration: 'enable': 3, 'other': 1, 'disable': 2.
                 xfRFOutlierSetTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.3 unsigned32 read-write
This object handles Set Threshold for Outlier Alarm. 3 = Default value (0.3). - To calculate threshold use the following formula: SetTh/10. Default value: 3 Near end access: read-write. Far end access: no access.
                 xfRFOutlierCeaseTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.4 unsigned32 read-write
This object handles Cease Threshold for Outlier Alarm. 2 = Default value (0.2). - To calculate threshold use the following formula: SetTh/10. Default value: 2 Near end access: read-write. Far end access: no access.
                 xfRFRangeAgc 1.3.6.1.4.1.193.81.3.4.3.1.9.1.5 integer read-write
This object manage IfCable Range Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access. Enumeration: 'enable': 3, 'other': 1, 'disable': 2.
                 xfRFRangeSetTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.6 unsigned32 read-write
This object handles Set Threshold for Range Alarm. 30 = Default value (3). - To calculate threshold use the following formula: SetTh/10. Default value: 30 (dB/10) Near end access: read-write. Far end access: no access.
                 xfRFRangeCeaseTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.7 unsigned32 read-write
This object handles Cease Threshold for Range Alarm. 20 = Default value (2). - To calculate threshold use the following formula: SetTh/10. Default value: 20 (dB/10) Near end access: read-write. Far end access: no access.
                 xfRFStddevAgc 1.3.6.1.4.1.193.81.3.4.3.1.9.1.8 integer read-write
This object manage IfCable Stddev Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access. Enumeration: 'enable': 3, 'other': 1, 'disable': 2.
                 xfRFStddevSetTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.9 unsigned32 read-write
This object handles Set Threshold for Stddev Alarm. 50 = Default value (5). - To calculate threshold use the following formula: SetTh/10. Default value: 50 (dB/10) Near end access: read-write. Far end access: no access.
                 xfRFStddevCeaseTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.10 unsigned32 read-write
This object handles Cease Threshold for Stddev Alarm. 20 = Default value (2). - To calculate threshold use the following formula: SetTh/10. Default value: 20 (dB/10) Near end access: read-write. Far end access: no access.
                 xfRFDegradationAgc 1.3.6.1.4.1.193.81.3.4.3.1.9.1.11 integer read-write
This object manage IfCable Degradation Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access. Enumeration: 'enable': 3, 'other': 1, 'disable': 2.
                 xfRFDegradationSetTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.12 unsigned32 read-write
This object handles Set Threshold for Degradation Alarm. 2 = Default value (0.2). - To calculate threshold use the following formula: SetTh/10. Default value: 2 (dB/10) Near end access: read-write. Far end access: no access.
                 xfRFDegradationCeaseTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.13 unsigned32 read-write
This object handles Cease Threshold for Degradation Alarm. 1 = Default value (0.1). - To calculate threshold use the following formula: SetTh/10. Default value: 1 (dB/10) Near end access: read-write. Far end access: no access.
                 xfRFMarginAgc 1.3.6.1.4.1.193.81.3.4.3.1.9.1.14 integer read-write
This object manage IfCable Margin Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access. Enumeration: 'enable': 3, 'other': 1, 'disable': 2.
                 xfRFMarginSetTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.15 unsigned32 read-write
This object handles Set Threshold for Margin Alarm. 30 = Default value (3). - To calculate threshold use the following formula: SetTh/10. Default value: 30 (dB/10) Near end access: read-write. Far end access: no access.
                 xfRFMarginCeaseTh 1.3.6.1.4.1.193.81.3.4.3.1.9.1.16 unsigned32 read-write
This object handles Cease Threshold for Margin Alarm. 60 = Default value (6). - To calculate threshold use the following formula: SetTh/10. Default value: 60 (dB/10) Near end access: read-write. Far end access: no access.
                 xfRFOutlierValue 1.3.6.1.4.1.193.81.3.4.3.1.9.1.17 integer32 read-only
This object handles the value calculated on 24h for Outlier Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 Near end access: read-write. Far end access: no access.
                 xfRFRangeValue 1.3.6.1.4.1.193.81.3.4.3.1.9.1.18 integer32 read-only
This object handles the value calculated on 24h for Range Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 (dB/100) Near end access: read-write. Far end access: no access.
                 xfRFStddevValue 1.3.6.1.4.1.193.81.3.4.3.1.9.1.19 integer32 read-only
This object handles the value calculated on 24h for Stddev Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 (dB/100) Near end access: read-write. Far end access: no access.
                 xfRFDegradationValue 1.3.6.1.4.1.193.81.3.4.3.1.9.1.20 integer32 read-only
This object handles the value calculated on 24h for Degradation Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 (dB/100) Near end access: read-write. Far end access: no access.
                 xfRFMarginValue 1.3.6.1.4.1.193.81.3.4.3.1.9.1.21 integer32 read-only
This object handles the value calculated on 24h for Margin Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 (dB/100) Near end access: read-write. Far end access: no access.
                 xfRFOutlierTrigger 1.3.6.1.4.1.193.81.3.4.3.1.9.1.22 integer read-only
This object manage IfCable Outlier Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access. Enumeration: 'other': 1, 'setThreshold': 3, 'noSetThreshold': 2.
                 xfRFRangeTrigger 1.3.6.1.4.1.193.81.3.4.3.1.9.1.23 integer read-only
This object manage IfCable Range Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access. Enumeration: 'other': 1, 'setThreshold': 3, 'noSetThreshold': 2.
                 xfRFStddevTrigger 1.3.6.1.4.1.193.81.3.4.3.1.9.1.24 integer read-only
This object manage IfCable Stddev Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access. Enumeration: 'other': 1, 'setThreshold': 3, 'noSetThreshold': 2.
                 xfRFDegradationTrigger 1.3.6.1.4.1.193.81.3.4.3.1.9.1.25 integer read-only
This object manage IfCable Degradation Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access. Enumeration: 'other': 1, 'setThreshold': 3, 'noSetThreshold': 2.
                 xfRFMarginTrigger 1.3.6.1.4.1.193.81.3.4.3.1.9.1.26 integer read-only
This object manage IfCable Margin Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access. Enumeration: 'other': 1, 'setThreshold': 3, 'noSetThreshold': 2.
         xfSdcTable 1.3.6.1.4.1.193.81.3.4.3.1.10 no-access
Table for SDC capabilities, setting and status.
               xfSdcEntry 1.3.6.1.4.1.193.81.3.4.3.1.10.1 no-access
An entry in the xfSdcTable.
                   xfSdcCapability 1.3.6.1.4.1.193.81.3.4.3.1.10.1.1 integer read-only
SDC capability, including both MMU and ODU. Enumeration: 'sdcSupported': 2, 'other': 1, 'sdcNotSupported': 3.
                   xfSdcAdminStatus 1.3.6.1.4.1.193.81.3.4.3.1.10.1.2 integer read-write
SDC Admin Status. Enumeration: 'other': 1, 'sdcEnabled': 2, 'sdcDisabled': 3.
                   xfSdcOperStatus 1.3.6.1.4.1.193.81.3.4.3.1.10.1.3 integer read-only
SDC Oper Status. Enumeration: 'sdcInProgress': 4, 'other': 1, 'sdcEnabled': 2, 'sdcDisabled': 3.
                   xfSdcDadeControl 1.3.6.1.4.1.193.81.3.4.3.1.10.1.4 integer read-write
SDC DADE procedure control. Enumeration: 'sdcDadeStart': 2, 'sdcDadeAbort': 3, 'other': 1.
                   xfSdcDadeStatus 1.3.6.1.4.1.193.81.3.4.3.1.10.1.5 integer read-only
SDC DADE procedure status. Enumeration: 'sdcCalibrated': 2, 'sdcCalInProgress': 4, 'sdcCalMismatch': 5, 'other': 1, 'sdcNotCalibrated': 3.
                   xfSdcPath 1.3.6.1.4.1.193.81.3.4.3.1.10.1.6 integer read-write
SDC selected path (desired value). Enumeration: 'sdcDiv': 4, 'other': 1, 'sdcMain': 3, 'sdcAuto': 2.
                   xfSdcOduDateTimeCalibration 1.3.6.1.4.1.193.81.3.4.3.1.10.1.7 displaystring read-only
Date and time of the SDC DADE calibration for the ODU with serial number in xfSdcOduSerialNumber. Format: [YYYY]-[MM]-[DD]T[hh]:[mm]:[ss] (ISO 8601).
                   xfSdcOduSerialNumber 1.3.6.1.4.1.193.81.3.4.3.1.10.1.8 displaystring read-only
Serial number of the ODU the current value of xfSdcOduDateTimeCalibration is referred to.
                   xfSdcGain 1.3.6.1.4.1.193.81.3.4.3.1.10.1.9 integer32 read-only
SDC gain in dB/10. Domain: [0.0 .. 3.0 dB].
                   xfSdcActualPath 1.3.6.1.4.1.193.81.3.4.3.1.10.1.10 integer read-only
SDC actual path (current value). Enumeration: 'sdcDiv': 4, 'other': 1, 'sdcMain': 3, 'sdcAuto': 2.
                   xfSdcDadeDelay 1.3.6.1.4.1.193.81.3.4.3.1.10.1.11 integer32 read-only
DADE delay in nsec.
     xfRadioLinkPtpRadioConformance 1.3.6.1.4.1.193.81.3.4.3.2
         xfRadioLinkPtpRadioCompliances 1.3.6.1.4.1.193.81.3.4.3.2.1
             xfRADIOLINKPTPRADIOFullCompliance 1.3.6.1.4.1.193.81.3.4.3.2.1.1
The compliance statement for SNMP entities which implement everything.
         xfRadioLinkPtpRadioGroups 1.3.6.1.4.1.193.81.3.4.3.2.2
             xfRadioLinkPtpRadioCompleteGroup 1.3.6.1.4.1.193.81.3.4.3.2.2.1
A collection of all current objects in this MIB module.