Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wfOc12ConfigTable 1.3.6.1.4.1.18.3.4.24.20 no-access
Statistics for the SONET medium table
       wfOc12ConfigEntry 1.3.6.1.4.1.18.3.4.24.20.1 no-access
An entry in the medium table
           wfOc12ConfigDelete 1.3.6.1.4.1.18.3.4.24.20.1.1 integer read-write
Create/Delete parameter Enumeration: 'deleted': 2, 'created': 1.
           wfOc12ConfigDisable 1.3.6.1.4.1.18.3.4.24.20.1.2 integer read-write
Create/Delete parameter Enumeration: 'disabled': 2, 'enabled': 1.
           wfOc12ConfigIndex 1.3.6.1.4.1.18.3.4.24.20.1.3 integer read-only
Index for this physical Sonet interface.
           wfOc12ConfigIfIndex 1.3.6.1.4.1.18.3.4.24.20.1.4 integer read-only
this is value of ifIndex from the Interfaces table of MIB II (RFC 1213).
           wfOc12ConfigState 1.3.6.1.4.1.18.3.4.24.20.1.5 integer read-only
State of the OC12 Port. Enumeration: 'lof': 4, 'loopback': 7, 'up': 1, 'ais': 5, 'down': 2, 'los': 3, 'notpresent': 20, 'rdi': 6.
           wfOc12ConfigLineStatus 1.3.6.1.4.1.18.3.4.24.20.1.6 integer read-only
the status of the OC12 Enumeration: 'lof': 4, 'loopback': 128, 'otherfailure': 512, 'noalarm': 1, 'ais': 8, 'los': 2, 'rdi': 16.
           wfOc12ConfigLastChange 1.3.6.1.4.1.18.3.4.24.20.1.7 timeticks read-only
The value of sysUpTime at the time the interface entered its current operational state.
           wfOc12ConfigType 1.3.6.1.4.1.18.3.4.24.20.1.8 integer read-only
This variable identifies whether a SONET or a SDH signal is used across this interface. Enumeration: 'sonet': 1, 'sdh': 2.
           wfOc12ConfigLineCoding 1.3.6.1.4.1.18.3.4.24.20.1.9 integer read-write
This variable describes the line coding for this interface. Enumeration: 'b3zs': 2, 'nrz': 4, 'other': 1, 'rz': 5, 'cmi': 3.
           wfOc12ConfigLineType 1.3.6.1.4.1.18.3.4.24.20.1.10 integer read-write
This variable describes the line type for this interface. Enumeration: 'longsinglemode': 3, 'shortsinglemode': 2, 'coax': 5, 'utp': 6, 'other': 1, 'multimode': 4.
           wfOc12ConfigLoopbackConfig 1.3.6.1.4.1.18.3.4.24.20.1.11 integer read-write
the loopback configuration of the OC12 interface Enumeration: 'lineloop': 3, 'noloop': 1, 'payloadloop': 2.
           wfOc12ConfigManagerMethod 1.3.6.1.4.1.18.3.4.24.20.1.12 integer read-write
This attribute has no affect on the Hardware configuration. This attribute is purely for any Network Management Tool to determine whether it configured the OC12 as Fractional or Clear. Enumeration: 'clear': 2, 'frac': 1.