Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wfMcT1ModTable 1.3.6.1.4.1.18.3.4.8.1 no-access
MCT1 MOD record - Contains MCT1 module Configuration parameters
     wfMcT1ModEntry 1.3.6.1.4.1.18.3.4.8.1.1 no-access
An entry in the MCT1 Base table
         wfMcT1ModDelete 1.3.6.1.4.1.18.3.4.8.1.1.1 integer read-write
Create/Delete parameter Enumeration: 'deleted': 2, 'created': 1.
         wfMcT1ModDisable 1.3.6.1.4.1.18.3.4.8.1.1.2 integer read-write
Enable/Disable parameter Enumeration: 'disabled': 2, 'enabled': 1.
         wfMcT1ModSlot 1.3.6.1.4.1.18.3.4.8.1.1.3 integer read-only
Instance ID slot, filled in by driver
         wfMcT1ModPrimaryClock 1.3.6.1.4.1.18.3.4.8.1.1.4 integer read-write
Specifies the primary source for T1 transmit timing. Both T1 ports use the same T1 transmit timing source. The options for T1 timing source are internal timing source, loop timing from either T1 port and an external timing source. Enumeration: 'int': 4, 'loop1': 3, 'loop0': 2, 'external': 1.
         wfMcT1ModSecondaryClock 1.3.6.1.4.1.18.3.4.8.1.1.5 integer read-write
Specifies the secondary source for T1 transmit timing. During normal operation T1 transmit timing is derived from the primary timing source. If the primary timing source fails, the software switches to secondary timing source. Enumeration: 'int': 4, 'loop1': 3, 'loop0': 2, 'external': 1.
         wfMcT1ModCurrentClock 1.3.6.1.4.1.18.3.4.8.1.1.6 integer read-only
Indicates the clock source currently in use Enumeration: 'int': 3, 'primary': 1, 'secondary': 2.
         wfMcT1ModExtClockOperational 1.3.6.1.4.1.18.3.4.8.1.1.7 integer read-only
Indicates whether the External clock is operational Enumeration: 'oper': 1, 'unoper': 2.
         wfMcT1ModLoop0ClockOperational 1.3.6.1.4.1.18.3.4.8.1.1.8 integer read-only
Indicates whether the timing source from port 1 is operational Enumeration: 'oper': 1, 'unoper': 2.
         wfMcT1ModLoop1ClockOperational 1.3.6.1.4.1.18.3.4.8.1.1.9 integer read-only
Indicates whether the timing source from port 2 is operational Enumeration: 'oper': 1, 'unoper': 2.
         wfMcT1ModRestart 1.3.6.1.4.1.18.3.4.8.1.1.10 integer read-write
Indicates Module gate should be restarted to read new configuration
 wfMcT1Table 1.3.6.1.4.1.18.3.4.8.2 no-access
MCT1 line record - Contains MUNICH32 Configuration parameters
     wfMcT1Entry 1.3.6.1.4.1.18.3.4.8.2.1 no-access
An entry in the MCT1 table
         wfMcT1Delete 1.3.6.1.4.1.18.3.4.8.2.1.1 integer read-write
Create/Delete parameter Enumeration: 'deleted': 2, 'created': 1.
         wfMcT1Disable 1.3.6.1.4.1.18.3.4.8.2.1.2 integer read-write
Enable/Disable parameter Enumeration: 'disabled': 2, 'enabled': 1.
         wfMcT1State 1.3.6.1.4.1.18.3.4.8.2.1.3 integer read-only
Line Driver state variable Enumeration: 'bert': 3, 'loopback': 4, 'up': 2, 'init': 1, 'notpresent': 8, 'redalarm': 5, 'yelalarm': 6, 'bluealarm': 7.
         wfMcT1Slot 1.3.6.1.4.1.18.3.4.8.2.1.4 integer read-only
Instance ID Slot, filled in by driver
         wfMcT1Connector 1.3.6.1.4.1.18.3.4.8.2.1.5 integer read-only
Instance ID Connector, filled in by driver Enumeration: 'two': 2, 'one': 1.
         wfMcT1OperationMode 1.3.6.1.4.1.18.3.4.8.2.1.6 integer read-write
An option to generate and analyze specific test patterns is provided in BERT mode of operation. Only one T1 port can be in BERT mode at a time. This attribute selects normal or BERT mode of operation Enumeration: 'default': 1, 'bert': 2.
         wfMcT1Mtu 1.3.6.1.4.1.18.3.4.8.2.1.7 integer read-write
MTU parameter. Specifies the largest frame size that can be received by the MCT1 link module. Any received frame which is larger than the MTU will be discarded.
         wfMcT1MunichVersion 1.3.6.1.4.1.18.3.4.8.2.1.8 integer read-only
Specifies version number of the MUNICH chip used Enumeration: 'v1': 1, 'v2': 2.
         wfMcT1Dsx1LineType 1.3.6.1.4.1.18.3.4.8.2.1.9 integer read-write
Selects between the two framing formats supported - D4 and ESF. The sailent differences between the two formats are the number of frames per superframe and the use of F-bit position. Enumeration: 'esf': 2, 'd4': 3.
         wfMcT1Dsx1ZeroCoding 1.3.6.1.4.1.18.3.4.8.2.1.10 integer read-write
Selects between the two Zero Code Suppression formats used on the link. In B8ZS coding, any outgoing stream of eight consecutive zeroes is replaced with a B8ZS code word. Any received B8ZS code is replaced with all zeroes. Enumeration: 'ami': 5, 'b8zs': 2.
         wfMcT1Dsx1LoopbackConfig 1.3.6.1.4.1.18.3.4.8.2.1.11 integer read-only
Indicates the loopback configuration of the T1 interface. The interface can be in the following loopback states: Payload loopback and Line loopback or no loopback. The loopbacks can be initiated by the manager of this device or by the far end. The loopbacks initiated by the far end are NETREQPAYLOADLOOP and NETREQLINELOOP. Enumeration: 'noloop': 1, 'mgrlineloop': 3, 'netreqpayloadloop': 4, 'mgrpayloadloop': 2, 'otherloop': 6, 'netreqlineloop': 5.
         wfMcT1Dsx1LineStatus 1.3.6.1.4.1.18.3.4.8.2.1.12 integer read-only
Indicates the line status of the T1 interface. It contains loopback state and alarm state information. The Dsx1LineStatus is a bit map therefore it can represent multiple loopback and alarm states simultaneously. Enumeration: 'farendalarm': 2, 'lossofframe': 8, 'noalarm': 1, 'loopbackstate': 32, 'alarmindicationsignal': 4, 'lossofsignal': 16.
         wfMcT1Dsx1SetupAlarmThreshold 1.3.6.1.4.1.18.3.4.8.2.1.13 integer read-write
Specifies setup time for performance failure conditions, in seconds. When a performance defect is present for greater than the time specified by this parameter a performance failure is registered and a message is logged. Enumeration: 'threshold10': 10, 'threshold8': 8, 'threshold2': 2, 'threshold4': 4, 'threshold6': 6.
         wfMcT1Dsx1ClearAlarmThreshold 1.3.6.1.4.1.18.3.4.8.2.1.14 integer read-write
Specifies clear time for performance failure conditions, in seconds. When a performance failure condition has been cleared for greater than the time specified by this parameter then the failure cleared condition is registered and a message is logged. Enumeration: 'threshold10': 10, 'threshold8': 8, 'threshold2': 2, 'threshold4': 4, 'threshold6': 6.
         wfMcT1Dsx1SignalLevel 1.3.6.1.4.1.18.3.4.8.2.1.15 integer read-write
Specifies T1 transmit power level, in terms of DB. They translate into cable length as follows: 0.0dB -> 0-133 ft 0.5dB -> 133-266 ft 0.8dB -> 266-399 ft 1.1dB -> 399-533 ft 1.5dB -> 533-655 ft Enumeration: 'pluspoint8': 5, 'pluspoint5': 4, 'minus7point5': 2, 'plus1point1': 6, 'plus1point5': 7, 'minus15': 1, 'minus0': 3.
         wfMcT1LoopbackDisable 1.3.6.1.4.1.18.3.4.8.2.1.16 integer read-write
The MCT1 link module is capable of detecting loop up and loop down codes received from the far end. This parameter enables or disbales loop up/down code detection circuitry Enumeration: 'disabled': 2, 'enabled': 1.
         wfMcT1Dsx1FDLOperationMode 1.3.6.1.4.1.18.3.4.8.2.1.17 integer read-write
Select between the two FDL modes of operation. The AT&T mode, 54016 is based on AT&T publication 54015-1989. The ANSI mode, T1403 is based on ANSI publication T1.403-1989 Enumeration: 'oper54016': 1, 'opert1403': 2.
         wfMcT1BertTxOutputLevel 1.3.6.1.4.1.18.3.4.8.2.1.18 integer read-write
Specifies T1 transmit power level, in terms of DB while the T1 port is in BERT mode. The power levels translate into cable length as follows: 0.0dB -> 0-133 ft 0.5dB -> 133-266 ft 0.8dB -> 266-399 ft 1.1dB -> 399-533 ft 1.5dB -> 533-655 ft Enumeration: 'pluspoint8': 5, 'pluspoint5': 4, 'minus7point5': 2, 'plus1point1': 6, 'plus1point5': 7, 'minus15': 1, 'minus0': 3.
         wfMcT1BertTestMode 1.3.6.1.4.1.18.3.4.8.2.1.19 integer read-write
Selects between the framing formats while in bert mode of operation. Enumeration: 'esf': 3, 'sf': 2, 't1': 1.
         wfMcT1BertLineCode 1.3.6.1.4.1.18.3.4.8.2.1.20 integer read-write
Selects between the two Zero Code Suppression formats used on the link while in BERT mode. In B8ZS coding, any outgoing stream of eight consecutive zeroes is replaced with a B8ZS code word. Any received B8ZS code is replaced with all zeroes. Enumeration: 'ami': 1, 'b8zs': 2.
         wfMcT1BertTestPattern 1.3.6.1.4.1.18.3.4.8.2.1.21 integer read-write
When a T1 port is in BERT mode, it is capable of generating a set of known patterns. This paramater selects between those patterns Enumeration: 'twentythreeinv': 8, 'qrss': 3, 'twenty': 6, 'fifteeninv': 5, 'twentythree': 7, 'ones': 2, 'zeros': 1, 'fifteen': 4.
         wfMcT1BertSendAlarm 1.3.6.1.4.1.18.3.4.8.2.1.22 integer read-write
Specifies a blue or yellow alarm to be transmitted while in BERT mode. Enumeration: 'blue': 1, 'disabled': 3, 'yellow': 2.
         wfMcT1DS2282Version 1.3.6.1.4.1.18.3.4.8.2.1.23 integer read-only
Specifies version number of DS2282 chip
         wfMcT1Restart 1.3.6.1.4.1.18.3.4.8.2.1.24 integer read-write
Indicates Port gate should be restarted to read new configuration
         wfMcT1Loopback 1.3.6.1.4.1.18.3.4.8.2.1.25 integer read-write
Selects line or payload loopback to be activated locally Enumeration: 'deactivate': 3, 'payldlb': 2, 'linelb': 1.
         wfMcT1FDLTargetAddress 1.3.6.1.4.1.18.3.4.8.2.1.26 integer read-write
Selects between the two FDL target address modes Enumeration: 'az': 1, 'by': 2.
 wfMcT1ConfigTable 1.3.6.1.4.1.18.3.4.8.3 no-access
MCT1 configuration record - Contains MUNICH32 and Framer write only Configuration parameters
     wfMcT1ConfigEntry 1.3.6.1.4.1.18.3.4.8.3.1 no-access
An entry in the MCT1 Config table
         wfMcT1ConfigSlot 1.3.6.1.4.1.18.3.4.8.3.1.1 integer read-only
Instance ID Slot, filled in by driver
         wfMcT1ConfigConnector 1.3.6.1.4.1.18.3.4.8.3.1.2 integer read-only
Instance ID Connector, filled in by driver Enumeration: 'two': 2, 'one': 1.
         wfMcT1BertRestart 1.3.6.1.4.1.18.3.4.8.3.1.3 integer read-write
Reset counters on BERT device Enumeration: 'restart': 1, 'noaction': 10.
         wfMcT1BertPayldLb 1.3.6.1.4.1.18.3.4.8.3.1.4 integer read-write
Selects a payload loopback code to be sent to the far end by the FDL while in BERT mode. It can be a payload loopback activate or deactivate code. Enumeration: 'noaction': 10, 'deact': 2, 'act': 1.
         wfMcT1BertLineLb 1.3.6.1.4.1.18.3.4.8.3.1.5 integer read-write
Selects a line loopback code to be sent to the far end while in BERT mode. It can be a line loopback activate or deactivate code using the hardware on the MCT1 board or it can be a code sent by the FDL. Enumeration: 'fdldeact': 4, 'lpdn': 2, 'noaction': 10, 'fdlact': 3, 'lpup': 1.
         wfMcT1BertErrorInsert 1.3.6.1.4.1.18.3.4.8.3.1.6 integer read-write
Indicates that an error be injected into the transmitted data stream while in BERT mode. Enumeration: 'millionconfig': 3, 'config': 1, 'disable': 4, 'thousandconfig': 2, 'noaction': 10.
         wfMcT1Dsx1SendLoopCode 1.3.6.1.4.1.18.3.4.8.3.1.7 integer read-write
Selects a Loop Up/Down code to be sent to the remote end Enumeration: 'noaction': 10, 'loopdn': 2, 'loopup': 1.
         wfMcT1Dsx1SendFDLCode 1.3.6.1.4.1.18.3.4.8.3.1.8 integer read-write
Selects an FDL code to be sent to the remote end Enumeration: 'ci': 1, 'pyldlbact': 5, 'pyldlbdeact': 6, 'univlbdeact': 2, 'noaction': 10, 'linelbdeact': 4, 'ia': 3, 'ib': 7.
 wfMcT1LineTable 1.3.6.1.4.1.18.3.4.8.4 no-access
MCT1 Channel record - Contains configuration parameters and statistics for MUNICH32 which are channel specific.
     wfMcT1LineEntry 1.3.6.1.4.1.18.3.4.8.4.1 no-access
An entry in the MCT1CHANNEL table
         wfMcT1LineDelete 1.3.6.1.4.1.18.3.4.8.4.1.1 integer read-write
Create/Delete parameter Enumeration: 'deleted': 2, 'created': 1.
         wfMcT1LineDisable 1.3.6.1.4.1.18.3.4.8.4.1.2 integer read-write
Enable/Disable parameter Enumeration: 'disabled': 2, 'enabled': 1.
         wfMcT1LineState 1.3.6.1.4.1.18.3.4.8.4.1.3 integer read-only
Line Driver state variable Enumeration: 'loopback': 4, 'stop': 7, 'up': 1, 'down': 2, 'init': 3, 'notpresent': 8, 'channel': 6, 'wait': 5.
         wfMcT1LineSlot 1.3.6.1.4.1.18.3.4.8.4.1.4 integer read-only
Instance ID Slot, filled in by driver
         wfMcT1LineConnector 1.3.6.1.4.1.18.3.4.8.4.1.5 integer read-only
Instance ID Connector, filled in by driver Enumeration: 'two': 2, 'one': 1.
         wfMcT1LineLine 1.3.6.1.4.1.18.3.4.8.4.1.6 integer read-only
Line number for this line instance, filled in by driver. The line number corresponds to the position of the circuit, from 1 to 24, on the port.
         wfMcT1LineCct 1.3.6.1.4.1.18.3.4.8.4.1.7 integer read-write
Circuit number for this line instance
         wfMcT1LineBofl 1.3.6.1.4.1.18.3.4.8.4.1.8 integer read-write
Selects Breath of Life (BOFL) parameter. If selected, a BOFL packet is sent out on the wire as often as specifies by the wfMcT1LineBoflTmo parameter Enumeration: 'disabled': 2, 'enabled': 1.
         wfMcT1LineBoflTmo 1.3.6.1.4.1.18.3.4.8.4.1.9 integer read-write
Indicates the time-period between BOFL packets
         wfMcT1LineFractionalLpbk 1.3.6.1.4.1.18.3.4.8.4.1.10 integer read-write
Any circuit on this T1 port is capable of being put into loopback, i.e. data coming into that circuit from the wire is mirrorred back onto the wire. This parameter enables or disables this loopback feature on any circuit. Enumeration: 'disabled': 2, 'enabled': 1.
         wfMcT1LineChannelAssignment 1.3.6.1.4.1.18.3.4.8.4.1.11 displaystring read-write
Lists the time-slots which constitute this channel. User types in a list of time-slots from 1 to 24 separated by commas
         wfMcT1LineMadr 1.3.6.1.4.1.18.3.4.8.4.1.12 octet string read-only
Line MAC address, fixed - line driver fills in from the 48 bit address stored in the serial number prom.
         wfMcT1LineWanProtocol 1.3.6.1.4.1.18.3.4.8.4.1.13 integer read-write
WAN protocol selection is provided via this parameter. The supported protocols can be selected per circuit. Enumeration: 'sw': 6, 'standard': 1, 'switch': 5, 'ppp': 2, 'framerelay': 4, 'smds': 3.
         wfMcT1LineService 1.3.6.1.4.1.18.3.4.8.4.1.14 integer read-write
Service type for this circuit. Supports raw HDLC mode. Does not support LLC1 at this time. LLC1 mode will prefix the HDLC address and control fields to the frame. May support LLC1 mode in the future Enumeration: 'llc1': 2, 'hdlc': 1.
         wfMcT1LineRateAdaption 1.3.6.1.4.1.18.3.4.8.4.1.15 integer read-write
Determines the number of bits and their bit positions within the time-slot. 64k selection uses all 8 bits in the time-slot. The two 56k selections use 7 of the 8 bits in the time-slot. 56k_MSB does not use the most significant bit and 56k_LSB does not use the least significant bit in the time-slot. Enumeration: 'lsb': 3, 'adaption64k': 1, 'msb': 2.
         wfMcT1LineIFTF 1.3.6.1.4.1.18.3.4.8.4.1.16 integer read-write
Determines the Interframe time fill character to be transmitted by the MUNICH. In case of IFTF_FLAGS, 0x7E is sent and in case of IFTF_IDLES 0xff is sent as the interframe timefill characters. Enumeration: 'idles': 2, 'flags': 1.
         wfMcT1LineCRCSize 1.3.6.1.4.1.18.3.4.8.4.1.17 integer read-write
Determines the CRC Size. When CRC32 is selected a 32 bit CRC is appended to the frame being transmitted and a 32 bit CRC check is performed on the received frame. When CRC16 is selected, a 16 bit CRC is appended to the transmitted frame and a 16 bit CRC is performed. on the received frame. Enumeration: 'crc32': 1, 'crc16': 2.
         wfMcT1LineRxOctets 1.3.6.1.4.1.18.3.4.8.4.1.18 counter read-only
Number of octets received without error
         wfMcT1LineRxFrames 1.3.6.1.4.1.18.3.4.8.4.1.19 counter read-only
Number of frames received without error
         wfMcT1LineTxOctets 1.3.6.1.4.1.18.3.4.8.4.1.20 counter read-only
Number of octets transmitted without error
         wfMcT1LineTxFrames 1.3.6.1.4.1.18.3.4.8.4.1.21 counter read-only
Number of frames transmitted without error
         wfMcT1LineRxErrors 1.3.6.1.4.1.18.3.4.8.4.1.22 counter read-only
Number of receive errors
         wfMcT1LineTxErrors 1.3.6.1.4.1.18.3.4.8.4.1.23 counter read-only
Number of transmission errors
         wfMcT1LineLackRxResources 1.3.6.1.4.1.18.3.4.8.4.1.24 counter read-only
Number of Rx frames dropped due to lack of buffer resources
         wfMcT1LineLackTxResources 1.3.6.1.4.1.18.3.4.8.4.1.25 counter read-only
Number of Tx frames dropped due to lack of buffer resources
         wfMcT1LineTxUnderflows 1.3.6.1.4.1.18.3.4.8.4.1.26 counter read-only
Number of Tx frames dropped due to Transmit underflow
         wfMcT1LineRxOverflows 1.3.6.1.4.1.18.3.4.8.4.1.27 counter read-only
Number of Rx frames dropped due to Receive overflow
         wfMcT1LineRxNullFrames 1.3.6.1.4.1.18.3.4.8.4.1.28 counter read-only
Number of short frames received (with no data bytes)
         wfMcT1LineRxShortFrames 1.3.6.1.4.1.18.3.4.8.4.1.29 counter read-only
Number of short frames received (less than or equal to two data bytes)
         wfMcT1LineRxLossSyncs 1.3.6.1.4.1.18.3.4.8.4.1.30 counter read-only
Loss of synchronization on receiver
         wfMcT1LineRxCRCErrors 1.3.6.1.4.1.18.3.4.8.4.1.31 counter read-only
CRC error received
         wfMcT1LineRxNonOctetBits 1.3.6.1.4.1.18.3.4.8.4.1.32 counter read-only
Non-Octet bits received in frame
         wfMcT1LineRxLongFrames 1.3.6.1.4.1.18.3.4.8.4.1.33 counter read-only
Frame longer than MFL received
         wfMcT1LineRxAbortFrames 1.3.6.1.4.1.18.3.4.8.4.1.34 counter read-only
Aborted frame received
         wfMcT1LineRxDescOverflows 1.3.6.1.4.1.18.3.4.8.4.1.35 counter read-only
Receive overflow on chip buffer
         wfMcT1LineTurboBofl 1.3.6.1.4.1.18.3.4.8.4.1.36 integer read-write
DEBUG parameter - Turbo bofl enabled or disabled Enumeration: 'disabled': 2, 'enabled': 1.
         wfMcT1LineBoflNum 1.3.6.1.4.1.18.3.4.8.4.1.37 integer read-write
DEBUG parameter - Number of breath of life packets per breath of life
         wfMcT1LineBoflLen 1.3.6.1.4.1.18.3.4.8.4.1.38 integer read-write
DEBUG parameter - breath of life packet length
         wfMcT1LineRxIntProcs 1.3.6.1.4.1.18.3.4.8.4.1.39 counter read-only
Receive Interrupt processing count
         wfMcT1LineTxIntProcs 1.3.6.1.4.1.18.3.4.8.4.1.40 counter read-only
Tx interrupt processing count
         wfMcT1LineRxPktCorruptions 1.3.6.1.4.1.18.3.4.8.4.1.41 counter read-only
Corruption check on receive
         wfMcT1LineRxReplenMisses 1.3.6.1.4.1.18.3.4.8.4.1.42 counter read-only
Count of number of packet buffer misses while attempting to replenish driver receive ring
         wfMcT1LineRxIFCs 1.3.6.1.4.1.18.3.4.8.4.1.43 counter read-only
Number of times the device changes its interframe time-fill
         wfMcT1LineCfgTxQueueLength 1.3.6.1.4.1.18.3.4.8.4.1.44 integer read-write
Configured transmit queue length
         wfMcT1LineCfgRxQueueLength 1.3.6.1.4.1.18.3.4.8.4.1.45 integer read-write
Configured receive queue length
         wfMcT1LineTxQueueLength 1.3.6.1.4.1.18.3.4.8.4.1.46 integer read-only
Current transmit queue length
         wfMcT1LineRxQueueLength 1.3.6.1.4.1.18.3.4.8.4.1.47 integer read-only
Current Receive queue length
         wfMcT1LineTxQueueEmpty 1.3.6.1.4.1.18.3.4.8.4.1.48 integer read-only
The number of times the transmit ring is found empty when transmitting packets
         wfMcT1LineMtu 1.3.6.1.4.1.18.3.4.8.4.1.49 integer read-only
MTU read-only parameter. Specifies the largest frame size that can be received by the MCT1 link module. Any received frame which is larger than the MTU will be discarded. Can be set in MCT1Entry TABLE by the user
         wfMcT1LineRestart 1.3.6.1.4.1.18.3.4.8.4.1.50 integer read-write
Indicates channel gate should be restarted to read new configuration
         wfMcT1LineLineNumber 1.3.6.1.4.1.18.3.4.8.4.1.51 integer read-write
line number for this line instance
 wfMcT1Dsx1CurrentTable 1.3.6.1.4.1.18.3.4.8.5 no-access
The MCT1_DSX1 Current table
     wfMcT1Dsx1CurrentEntry 1.3.6.1.4.1.18.3.4.8.5.1 no-access
per circuit MCT1_DSX1 current objects - wfMcT1Dsx1CurrentIndex corresponds to Wellfleet circuit number
         wfMcT1Dsx1CurrentSlot 1.3.6.1.4.1.18.3.4.8.5.1.1 integer read-only
this corresponds to the Wellfleet Slot number
         wfMcT1Dsx1CurrentConnector 1.3.6.1.4.1.18.3.4.8.5.1.2 integer read-only
this corresponds to the Wellfleet Connector number Enumeration: 'two': 2, 'one': 1.
         wfMcT1Dsx1CurrentIntervalTimer 1.3.6.1.4.1.18.3.4.8.5.1.3 gauge read-only
the number of seconds in the current 15 minute interval
         wfMcT1Dsx1CurrentESs 1.3.6.1.4.1.18.3.4.8.5.1.4 gauge read-only
the number of errored seconds encountered by a DS1 interface in the current 15 minute interval
         wfMcT1Dsx1CurrentSESs 1.3.6.1.4.1.18.3.4.8.5.1.5 gauge read-only
the number of severely errored seconds in the current 15 minute interval
         wfMcT1Dsx1CurrentBESs 1.3.6.1.4.1.18.3.4.8.5.1.6 gauge read-only
the number of bursty errored seconds in the current 15 minute interval
         wfMcT1Dsx1CurrentUASs 1.3.6.1.4.1.18.3.4.8.5.1.7 gauge read-only
the number of unavailable seconds in the current 15 minute interval
         wfMcT1Dsx1CurrentCSSs 1.3.6.1.4.1.18.3.4.8.5.1.8 gauge read-only
the number of Controlled Slip seconds in the current 15 minute interval
         wfMcT1Dsx1CurrentBPVs 1.3.6.1.4.1.18.3.4.8.5.1.9 gauge read-only
the number of bipolar violations in the current 15 minute interval
 wfMcT1Dsx1IntervalTable 1.3.6.1.4.1.18.3.4.8.6 no-access
The MCT1_DSX1 Interval table
     wfMcT1Dsx1IntervalEntry 1.3.6.1.4.1.18.3.4.8.6.1 no-access
per circuit MCT1_DSX1 interval objects - wfMcT1Dsx1IntervalIndex corresponds to Wellfleet circuit number, wfMcT1Dsx1IntervalNumber is the numbered previous 15-minute interval
         wfMcT1Dsx1IntervalSlot 1.3.6.1.4.1.18.3.4.8.6.1.1 integer read-only
this corresponds to the Wellfleet Slot number
         wfMcT1Dsx1IntervalConnector 1.3.6.1.4.1.18.3.4.8.6.1.2 integer read-only
this corresponds to the Wellfleet Connector number Enumeration: 'two': 2, 'one': 1.
         wfMcT1Dsx1IntervalNumber 1.3.6.1.4.1.18.3.4.8.6.1.3 integer read-only
1..96 where 1 is the most recent 15-minute interval and 96 is the least
         wfMcT1Dsx1IntervalESs 1.3.6.1.4.1.18.3.4.8.6.1.4 gauge read-only
the number of errored seconds in the specified interval
         wfMcT1Dsx1IntervalSESs 1.3.6.1.4.1.18.3.4.8.6.1.5 gauge read-only
the number of severely errored seconds in the specified interval
         wfMcT1Dsx1IntervalBESs 1.3.6.1.4.1.18.3.4.8.6.1.6 gauge read-only
the number of bursty errored seconds in the specified interval
         wfMcT1Dsx1IntervalUASs 1.3.6.1.4.1.18.3.4.8.6.1.7 gauge read-only
the number of unavailable seconds in the specified interval
         wfMcT1Dsx1IntervalCSSs 1.3.6.1.4.1.18.3.4.8.6.1.8 gauge read-only
the number of controlled slip seconds in the specified interval
         wfMcT1Dsx1IntervalBPVs 1.3.6.1.4.1.18.3.4.8.6.1.9 gauge read-only
the number of bipolar violations in the specified interval
 wfMcT1Dsx1TotalTable 1.3.6.1.4.1.18.3.4.8.7 no-access
The MCT1_DSX1 Total table
     wfMcT1Dsx1TotalEntry 1.3.6.1.4.1.18.3.4.8.7.1 no-access
per circuit MCT1_DSX1 total objects - wfMcT1Dsx1TotalIndex corresponds to Wellfleet circuit number
         wfMcT1Dsx1TotalSlot 1.3.6.1.4.1.18.3.4.8.7.1.1 integer read-only
this corresponds to the Wellfleet Slot number
         wfMcT1Dsx1TotalConnector 1.3.6.1.4.1.18.3.4.8.7.1.2 integer read-only
this corresponds to the Wellfleet Connector number Enumeration: 'two': 2, 'one': 1.
         wfMcT1Dsx1TotalVITR 1.3.6.1.4.1.18.3.4.8.7.1.3 gauge read-only
Indicates the number of valid 15 minute intervals in the previous 24 hour period
         wfMcT1Dsx1TotalESs 1.3.6.1.4.1.18.3.4.8.7.1.4 gauge read-only
The number of errored seconds encountered by the DS1 interface in the previous 24 hour interval
         wfMcT1Dsx1TotalSESs 1.3.6.1.4.1.18.3.4.8.7.1.5 gauge read-only
The number of severely errored seconds encountered by a DS1 interface in the previous 24 hour interval
         wfMcT1Dsx1TotalBESs 1.3.6.1.4.1.18.3.4.8.7.1.6 gauge read-only
The number of bursty errored seconds encountered by a DS1 interface in the previous 24 hour interval
         wfMcT1Dsx1TotalUASs 1.3.6.1.4.1.18.3.4.8.7.1.7 gauge read-only
The number of unavailable seconds encountered by by a DS1 interface in the previous 24 hour interval
         wfMcT1Dsx1TotalCSSs 1.3.6.1.4.1.18.3.4.8.7.1.8 gauge read-only
The number of controlled slip seconds encountered by a DS1 interface in the previous 24 hour interval
         wfMcT1Dsx1TotalBPVs 1.3.6.1.4.1.18.3.4.8.7.1.9 gauge read-only
The number of bipolar violations encountered by a DS1 interface in the previous 24 hour interval
 wfMcT1AnsiTable 1.3.6.1.4.1.18.3.4.8.8 no-access
ANSI Statistics line record - This table contains the performance parameters for the ANSI register set
     wfMcT1AnsiEntry 1.3.6.1.4.1.18.3.4.8.8.1 no-access
An entry in the MCT1 Ansi table
         wfMcT1AnsiSlot 1.3.6.1.4.1.18.3.4.8.8.1.1 integer read-only
Instance ID Slot, filled in by driver
         wfMcT1AnsiConnector 1.3.6.1.4.1.18.3.4.8.8.1.2 integer read-only
Instance ID Connector, filled in by driver Enumeration: 'two': 2, 'one': 1.
         wfMcT1AnsiCRCCounts 1.3.6.1.4.1.18.3.4.8.8.1.3 counter read-only
Counts CRC-6 error events
         wfMcT1AnsiBPVCounts 1.3.6.1.4.1.18.3.4.8.8.1.4 counter read-only
Counts bipolar violations
         wfMcT1AnsiOOFCounts 1.3.6.1.4.1.18.3.4.8.8.1.5 counter read-only
Counts out-of-frame error events
         wfMcT1AnsiFECounts 1.3.6.1.4.1.18.3.4.8.8.1.6 counter read-only
Counts errors in the FPS framing pattern
         wfMcT1AnsiESCounts 1.3.6.1.4.1.18.3.4.8.8.1.7 counter read-only
Counts errorred seconds
         wfMcT1AnsiSESCounts 1.3.6.1.4.1.18.3.4.8.8.1.8 counter read-only
Counts severly errorred seconds
         wfMcT1AnsiUASCounts 1.3.6.1.4.1.18.3.4.8.8.1.9 counter read-only
counts unavailable seconds
         wfMcT1AnsiPRMR0Counts 1.3.6.1.4.1.18.3.4.8.8.1.10 counter read-only
Counts PRMs that ewre received in the FDL in the last four seconds
         wfMcT1AnsiPRMR1Counts 1.3.6.1.4.1.18.3.4.8.8.1.11 counter read-only
Counts PRMs that ewre received in the FDL in the last four seconds
         wfMcT1AnsiPRMR2Counts 1.3.6.1.4.1.18.3.4.8.8.1.12 counter read-only
Counts PRMs that ewre received in the FDL in the last four seconds
         wfMcT1AnsiPRMR3Counts 1.3.6.1.4.1.18.3.4.8.8.1.13 counter read-only
Counts PRMs that ewre received in the FDL in the last four seconds
         wfMcT1AnsiPRMESCounts 1.3.6.1.4.1.18.3.4.8.8.1.14 counter read-only
Counts errorred seconds as reported in the Performance report messages
         wfMcT1AnsiPRMSESCounts 1.3.6.1.4.1.18.3.4.8.8.1.15 counter read-only
Counts severely errorred seconds as reported in the Performance report messages
         wfMcT1AnsiPRMECounts 1.3.6.1.4.1.18.3.4.8.8.1.16 counter read-only
Counts Performance report messages that are received in error
 wfMcT1BertStatsTable 1.3.6.1.4.1.18.3.4.8.9 no-access
BERT Counter line record - This table contains the statistics for the BERT tester.
     wfMcT1BertStatsEntry 1.3.6.1.4.1.18.3.4.8.9.1 no-access
An entry in the MCT1 Bert Stats table
         wfMcT1BertStatsSlot 1.3.6.1.4.1.18.3.4.8.9.1.1 integer read-only
Instance ID Slot, filled in by driver
         wfMcT1BertStatsConnector 1.3.6.1.4.1.18.3.4.8.9.1.2 integer read-only
Instance ID Connector, filled in by driver Enumeration: 'two': 2, 'one': 1.
         wfMcT1BertStatsBitErrors 1.3.6.1.4.1.18.3.4.8.9.1.3 counter read-only
Bit error counter
         wfMcT1BertStatsBits 1.3.6.1.4.1.18.3.4.8.9.1.4 counter read-only
Bit counter