Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wfIRedundIfTable 1.3.6.1.4.1.18.3.5.1.10.1 no-access
WF_IREDUND_INTERFACE_TABLE - Interface REDUNDANCY This tabulates the interfaces within an interface redundancy group. All interfaces are indexed according to their physical slot and connector designation. All interfaces in the same circuit act as redundant (hot stand-by) interfaces for that circuit. At any given time, one hot stand-by interface is chosen to be the active interface for a circuit. The active interface is the only interface that is reading and writing data to/from the media.
     wfIRedundIfEntry 1.3.6.1.4.1.18.3.5.1.10.1.1 no-access
Redundant interface entries.
         wfIRedundIfDelete 1.3.6.1.4.1.18.3.5.1.10.1.1.1 integer read-write
Creation and deletion flag for this record. When set, it will cause this entry to be deleted from the MIB. Enumeration: 'deleted': 2, 'created': 1.
         wfIRedundIfDisable 1.3.6.1.4.1.18.3.5.1.10.1.1.2 integer read-write
Enable/Disable parameter. A disabled interface will never be selected as the active interface for a circuit. Enumeration: 'disabled': 2, 'enabled': 1.
         wfIRedundIfCct 1.3.6.1.4.1.18.3.5.1.10.1.1.3 integer read-write
The circuit number of the circuit to which the interface belongs. This interface will either act as the active interface for the the circuit or as a hot stand-by.
         wfIRedundIfSlot 1.3.6.1.4.1.18.3.5.1.10.1.1.4 integer read-only
Slot ID of the interface, used as instance ID
         wfIRedundIfPort 1.3.6.1.4.1.18.3.5.1.10.1.1.5 integer read-only
Port ID of the interface, used as instance ID
         wfIRedundIfPrimary 1.3.6.1.4.1.18.3.5.1.10.1.1.6 integer read-write
Primary flag, indicates if this has been chosen as the primary interface. Only one interface in any circuit can be selected as a PRIMARY interface. The PRIMARY interface will have priority when an active interface is selected for a circuit. In general, if a PRIMARY circuit is available at active interface selection time, it will be chosen as the active interface. Enumeration: 'nonprimary': 2, 'primary': 1.
         wfIRedundIfActive 1.3.6.1.4.1.18.3.5.1.10.1.1.7 integer read-only
Active flag, indicates if this interface is the current active interface for the Interface Redundancy Group, or a standby interface, or not available to be used as active interface. Enumeration: 'notavailable': 1, 'standby': 2, 'active': 3.
         wfIRedundIfMACAddr 1.3.6.1.4.1.18.3.5.1.10.1.1.8 octet string read-only
MAC Address being used by Interface Redundancy as Primary MAC Address.