Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wfHwfTable 1.3.6.1.4.1.18.3.4.6.1 no-access
The following table will contain information about a collection of Hardware Filter (HWF) driver records. Only one HWF driver may be spawned, by the loader, on a given slot. Hence, only the slot number is used as the instance identifier into the table.
     wfHwfEntry 1.3.6.1.4.1.18.3.4.6.1.1 no-access
Slot number used as instance identifier.
         wfHwfDelete 1.3.6.1.4.1.18.3.4.6.1.1.1 integer read-write
Create/delete parameter. Enumeration: 'deleted': 2, 'created': 1.
         wfHwfEnable 1.3.6.1.4.1.18.3.4.6.1.1.2 integer read-write
Enable/disable parameter. Enumeration: 'disabled': 2, 'enabled': 1.
         wfHwfState 1.3.6.1.4.1.18.3.4.6.1.1.3 integer read-only
Driver state variable. Enumeration: 'down': 2, 'init': 3, 'up': 1, 'notpresent': 4.
         wfHwfSlot 1.3.6.1.4.1.18.3.4.6.1.1.4 integer read-only
Slot number -- instance ID.
         wfHwfAvailableLines 1.3.6.1.4.1.18.3.4.6.1.1.5 integer read-only
Number of available lines on module.
 wfHwfLineTable 1.3.6.1.4.1.18.3.4.6.2 no-access
The following table will contain information about a collection of Hardware Filter (HWF) line records.
     wfHwfLineEntry 1.3.6.1.4.1.18.3.4.6.2.1 no-access
Slot number and line number used as instance identifier.
         wfHwfLineState 1.3.6.1.4.1.18.3.4.6.2.1.1 integer read-only
State of filtering hardware on a per line basis. Enumeration: 'disabled': 2, 'full': 3, 'operational': 1.
         wfHwfLineSlot 1.3.6.1.4.1.18.3.4.6.2.1.2 integer read-only
Slot number -- instance ID.
         wfHwfLineNumber 1.3.6.1.4.1.18.3.4.6.2.1.3 integer read-only
Line number -- instance ID. Enumeration: 'four': 4, 'three': 3, 'five': 5, 'two': 2, 'one': 1.
         wfHwfLineCct 1.3.6.1.4.1.18.3.4.6.2.1.4 integer read-only
Circuit number associated with a line.
         wfHwfLineCapableMaxTblSize 1.3.6.1.4.1.18.3.4.6.2.1.5 integer read-only
This attribute specifies the maximum number of table entries capable of being used by a line based upon actual hardware filter devices present and available.
         wfHwfLineCurrentTblSize 1.3.6.1.4.1.18.3.4.6.2.1.6 integer read-only
Current capacity of the hardware filter table. Hardware filter table resources are dynamically allocated (in increments of 256) on an as-needed basis up to the available table size.
         wfHwfLineCurrentUsedEntries 1.3.6.1.4.1.18.3.4.6.2.1.7 integer read-only
Number of hardware filter table entries used.
         wfHwfLineDroppedFrames 1.3.6.1.4.1.18.3.4.6.2.1.8 integer read-only
Number of frames dropped because of hardware filter match.