Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wfHssiTable 1.3.6.1.4.1.18.3.4.7 no-access
HSSI line record
     wfHssiEntry 1.3.6.1.4.1.18.3.4.7.1 no-access
An entry in the HSSI table
         wfHssiDelete 1.3.6.1.4.1.18.3.4.7.1.1 integer read-write
Create/Delete parameter Enumeration: 'deleted': 2, 'created': 1.
         wfHssiDisable 1.3.6.1.4.1.18.3.4.7.1.2 integer read-write
Enable/Disable parameter Enumeration: 'disabled': 2, 'enabled': 1.
         wfHssiState 1.3.6.1.4.1.18.3.4.7.1.3 integer read-only
Line Driver state variable, Not Present, Init, Down, Up Enumeration: 'dteloopback': 7, 'lineloopbofltest': 19, 'boflwait': 3, 'up': 1, 'init': 5, 'cawait': 4, 'notpres': 20, 'notpresent': 6, 'dceloopbacktmo': 10, 'dceloopback': 8, 'lmiwait': 2, 'dceloopbackwait': 9.
         wfHssiSlot 1.3.6.1.4.1.18.3.4.7.1.4 integer read-only
Instance ID Slot, filled in by driver
         wfHssiConnector 1.3.6.1.4.1.18.3.4.7.1.5 integer read-only
Instance ID Connector, filled in by driver Enumeration: 'four': 4, 'three': 3, 'two': 2, 'one': 1.
         wfHssiCct 1.3.6.1.4.1.18.3.4.7.1.6 integer read-write
CCT number for this line instance
         wfHssiBofl 1.3.6.1.4.1.18.3.4.7.1.7 integer read-write
breath of life parameter Enumeration: 'disabled': 2, 'enabled': 1.
         wfHssiBoflTmo 1.3.6.1.4.1.18.3.4.7.1.8 integer read-write
breath of life frequency in seconds
         wfHssiMtu 1.3.6.1.4.1.18.3.4.7.1.9 integer read-write
MTU parameter, this is buffer size for HSSI media, fixed
         wfHssiMadr 1.3.6.1.4.1.18.3.4.7.1.10 octet string read-only
Line MAC address, fixed - line driver fills in from the 48 bit address stored in the serial number prom for this connector.
         wfHssiService 1.3.6.1.4.1.18.3.4.7.1.11 integer read-write
Service type for this circuit. Transparent is raw HDLC mode, and is the only service provided on the current HSSI product Enumeration: 'transparent': 1, 'undefined': 2.
         wfHssiWanProtocol 1.3.6.1.4.1.18.3.4.7.1.12 integer read-write
WAN protocol selection is provided via this parameter. The supported protocols can be selected per interface. Enumeration: 'passthr': 2, 'atm': 6, 'sw': 7, 'standard': 1, 'switch': 8, 'ppp': 3, 'framerelay': 5, 'smds': 4.
         wfHssiTransmissionInterface 1.3.6.1.4.1.18.3.4.7.1.13 integer read-write
T1 or T3, in the future OC1, OC3 and OC12. Used for MIB selection Enumeration: 'dsone': 1, 'dsthree': 3.
         wfHssiExternalClkSpeed 1.3.6.1.4.1.18.3.4.7.1.14 integer read-write
External Clock Speed, Used in the future for route selection
         wfHssiCrcSize 1.3.6.1.4.1.18.3.4.7.1.15 integer read-write
CRC size parameter, 16 bit standard CCITT or extended 32 bit CRC Enumeration: 'crc16bit': 1, 'crc32bit': 2.
         wfHssiInternalClkTestMode 1.3.6.1.4.1.18.3.4.7.1.16 integer read-write
Enables internal transmit clock generation. Should NEVER be enabled for normal operation. Enumeration: 'disabled': 2, 'enabled': 1.
         wfHssiRxOctets 1.3.6.1.4.1.18.3.4.7.1.17 counter read-only
Number of bytes received without error
         wfHssiRxFrames 1.3.6.1.4.1.18.3.4.7.1.18 counter read-only
Number of frames received without error
         wfHssiTxOctets 1.3.6.1.4.1.18.3.4.7.1.19 counter read-only
Number of bytes transmitted without error
         wfHssiTxFrames 1.3.6.1.4.1.18.3.4.7.1.20 counter read-only
Number of frames transmitted without error
         wfHssiInDiscards 1.3.6.1.4.1.18.3.4.7.1.21 counter read-only
Number of error-free inbound packets discarded. Usually due to lack of memory resources.
         wfHssiInErrors 1.3.6.1.4.1.18.3.4.7.1.22 counter read-only
Number of inbound packets not delivered to higher-layer protocol because of errors.
         wfHssiOutDiscards 1.3.6.1.4.1.18.3.4.7.1.23 counter read-only
Number of error-free outbound packets discarded. Usually due to lack of transmission bandwidth.
         wfHssiOutErrors 1.3.6.1.4.1.18.3.4.7.1.24 counter read-only
Number of outbound packets that could not be transmitted because of errors.
         wfHssiRxLongFrames 1.3.6.1.4.1.18.3.4.7.1.25 counter read-only
Number of Long frames dropped on receive because of length
         wfHssiTxClipFrames 1.3.6.1.4.1.18.3.4.7.1.26 counter read-only
Number of frames clipped in the transmit routine
         wfHssiRxReplenMisses 1.3.6.1.4.1.18.3.4.7.1.27 counter read-only
Number of failed attempts by the line driver to aquire a packet buffer
         wfHssiLastRxErrorCtrl 1.3.6.1.4.1.18.3.4.7.1.28 integer read-only
Last errored receive descriptor's control field
         wfHssiRxCrcErrors 1.3.6.1.4.1.18.3.4.7.1.29 counter read-only
Number of frames received with CRC errors
         wfHssiRxOverruns 1.3.6.1.4.1.18.3.4.7.1.30 counter read-only
Number of frames received with fifo overrun errors
         wfHssiRxAborts 1.3.6.1.4.1.18.3.4.7.1.31 counter read-only
Number of frames received with abort status
         wfHssiLastTxErrorCtrl 1.3.6.1.4.1.18.3.4.7.1.32 integer read-only
Last errored transmit descriptor's control field
         wfHssiTxAborts 1.3.6.1.4.1.18.3.4.7.1.33 counter read-only
Number of transmit frames with internal abort errors
         wfHssiTxUnderruns 1.3.6.1.4.1.18.3.4.7.1.34 counter read-only
Number of transmit frames aborted with underrun errors
         wfHssiRxRingErrors 1.3.6.1.4.1.18.3.4.7.1.35 counter read-only
Number of receive ring error events
         wfHssiLastRxRingState 1.3.6.1.4.1.18.3.4.7.1.36 integer read-only
Last 8 bit value from the recv ring state register
         wfHssiRxRingOverruns 1.3.6.1.4.1.18.3.4.7.1.37 counter read-only
Number of receive ring overrun events
         wfHssiTxRingErrors 1.3.6.1.4.1.18.3.4.7.1.38 counter read-only
Number of transmit ring error events
         wfHssiLastTxRingState 1.3.6.1.4.1.18.3.4.7.1.39 integer read-only
Last 8 bit value from the transmit ring state register
         wfHssiPortOpErrors 1.3.6.1.4.1.18.3.4.7.1.40 counter read-only
Number of port operation error events
         wfHssiInternOpErrors 1.3.6.1.4.1.18.3.4.7.1.41 counter read-only
Number of internal operation error events
         wfHssiHostErrors 1.3.6.1.4.1.18.3.4.7.1.42 counter read-only
Number of parity errs on host accesses to directly accessable registers.
         wfHssiRxProcessings 1.3.6.1.4.1.18.3.4.7.1.43 counter read-only
Number of receive frame processings (RINT)
         wfHssiTxProcessings 1.3.6.1.4.1.18.3.4.7.1.44 counter read-only
Number of transmit processings, invokations of transmit routine
         wfHssiTxCmplProcessings 1.3.6.1.4.1.18.3.4.7.1.45 counter read-only
Number of transmit complete processings (TINT)
         wfHssiIntrProcessings 1.3.6.1.4.1.18.3.4.7.1.46 counter read-only
Number of Interrupt processings, invokations of intr routine
         wfHssiBoflNum 1.3.6.1.4.1.18.3.4.7.1.47 integer read-write
Number of breath of life packets per breath of life
         wfHssiBoflLen 1.3.6.1.4.1.18.3.4.7.1.48 integer read-write
breath of life packet length
         wfHssiRxBufferLength 1.3.6.1.4.1.18.3.4.7.1.49 integer read-write
Performance tunning parameter controls Receive buffer size. Enumeration: 'length4k': 64, 'length8k': 128.
         wfHssiMemPageLength 1.3.6.1.4.1.18.3.4.7.1.50 integer read-write
Performance tunning parameter controls device memory access burst length. Enumeration: 'length256': 3, 'length32': 1.
         wfHssiRxRingLength 1.3.6.1.4.1.18.3.4.7.1.51 integer read-only
Current Receive Queue Length.
         wfHssiTxRingLength 1.3.6.1.4.1.18.3.4.7.1.52 integer read-only
Current Transmit Queue Length.
         wfHssiRxFifoWatermark 1.3.6.1.4.1.18.3.4.7.1.53 integer read-write
Performance tunning parameter controls the receive watermark.
         wfHssiTxFifoWatermark 1.3.6.1.4.1.18.3.4.7.1.54 integer read-write
Performance tunning parameter controls the transmit watermark.
         wfHssiMaxRxMemory 1.3.6.1.4.1.18.3.4.7.1.55 integer read-write
Performance tunning parameter controls fifo area allowed for receive.
         wfHssiLinkInterface 1.3.6.1.4.1.18.3.4.7.1.56 integer read-write
Only for DEBUG. Enumeration: 'default': 1, 'ace32': 3, 'ace25': 2.
         wfHssiTurboBofl 1.3.6.1.4.1.18.3.4.7.1.57 integer read-write
Only for DEBUG, Turbo breath of life parameter Enumeration: 'disabled': 2, 'enabled': 1.
         wfHssiCfgRxQueueLength 1.3.6.1.4.1.18.3.4.7.1.58 integer read-write
Configured Receive Queue Length. Values other than zero over-ride the router selected values. A value of zero has a special meaning. Zero causes router based default values to be used. Values larger than the compiled ring size are truncated to the compiled ring size.
         wfHssiCfgTxQueueLength 1.3.6.1.4.1.18.3.4.7.1.59 integer read-write
Configured Transmit Queue Length. Values other than zero over-ride the router selected values. A value of zero has a special meaning. Zero causes router based default values to be used. Values larger than the compiled ring size are truncated to the compiled ring size.
         wfHssiLineNumber 1.3.6.1.4.1.18.3.4.7.1.60 integer read-write
line number for this line instance
         wfHssiCfgCngstCtlEnable 1.3.6.1.4.1.18.3.4.7.1.61 integer read-write
Configured Congestion Control Enable. Enable or disable BNX switch congestion control on this HSSI port. Note that this has relevance only in the BNX switch and (currently) Frame Relay and SMDS switching functionality. If enabled, congestion control will monitor the levels of traffic and congestion and mark and drop certain packets as per of Frame Relay or SMDS protocols. See BNX doc for details on the congestion control strategy. Enumeration: 'enable': 1, 'disable': 2.
         wfHssiLastChange 1.3.6.1.4.1.18.3.4.7.1.62 timeticks read-only
The value of SysUpTime at the time the interface entered it's current operational state (UP state). SysUpTime is defined as the time (in hundredths of a second) since the network management portion of the system was last re-initialized. Usually the time since boot.
         wfHssiOutQLen 1.3.6.1.4.1.18.3.4.7.1.63 gauge read-only
The instantaneous current length of the output packet queue (in packets).
         wfHssiCarrLossDebounceTmo 1.3.6.1.4.1.18.3.4.7.1.64 integer read-write
This attribute determines how many seconds to wait before transitioning to the Carrier Lost state when the Carrier Signal is lost. When set to 0 (default), the Driver will immediately transition to the lost state upon detecting Carrier Loss. If the Carrier Signal returns prior to reaching this threshold, the Driver will not enter the Carrier Lost state at all.
         wfHssiModule 1.3.6.1.4.1.18.3.4.7.1.65 integer read-only
Module number for ASN platform, filled in by driver. For non-ASN platforms this attribute will not be used. Enumeration: 'four': 4, 'three': 3, 'two': 2, 'one': 1.
         wfHssiActualConnector 1.3.6.1.4.1.18.3.4.7.1.66 integer read-only
Actual connector number for ASN platform, filled in by driver. For non-ASN platforms, this attribute will not be used. Enumeration: 'seven': 7, 'six': 6, 'three': 3, 'two': 2, 'four': 4, 'five': 5, 'eight': 8, 'one': 1.
         wfHssiLoopback 1.3.6.1.4.1.18.3.4.7.1.67 integer read-write
Loopback type requested, Local Digital (Loop A), Local Line (Loop B), Remote Line (Loop C), or none Enumeration: 'none': 1, 'localline': 3, 'remoteline': 4, 'localdigital': 2.
         wfHssiReceiveAllFrames 1.3.6.1.4.1.18.3.4.7.1.68 integer read-write
This attribute enables delivery of all receive frames to the HSSI device driver for processing. When disabled, frames less than 4 bytes in length are filtered out of the receive frame stream before reaching the device driver. It is necessary to enable the attribute when running Frame Relay switched virtual circuits (SVC) in order to allow the reception of 3 byte frames. Enumeration: 'disabled': 2, 'enabled': 1.