Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wfFrSwDlcmiTable 1.3.6.1.4.1.18.3.5.9.6.1 no-access
The Parameters for the Data Link Connection Management Interface corresponding to any interface. Incorporates the Error table.
     wfFrSwDlcmiEntry 1.3.6.1.4.1.18.3.5.9.6.1.1 no-access
The parameters for a particular Data Link Connection Management Interface.
         wfFrSwDlcmiDelete 1.3.6.1.4.1.18.3.5.9.6.1.1.1 integer read-write
Indication to delete this frame relay interface. Enumeration: 'deleted': 2, 'created': 1.
         wfFrSwDlcmiState 1.3.6.1.4.1.18.3.5.9.6.1.1.2 integer read-only
Indicates which state of DLCMI the interface is in Enumeration: 'down': 2, 'init': 3, 'up': 1.
         wfFrSwDlcmiNniEnable 1.3.6.1.4.1.18.3.5.9.6.1.1.3 integer read-write
Indicates whether a NNI is enabled for this entry. Enumeration: 'disabled': 2, 'enabled': 1.
         wfFrSwDlcmiCircuit 1.3.6.1.4.1.18.3.5.9.6.1.1.4 integer read-only
Instance identifier; the circuit number of this entry.
         wfFrSwDlcmiManagementType 1.3.6.1.4.1.18.3.5.9.6.1.1.5 integer read-write
Indicates the Data Link Connection Management scheme that is active. Enumeration: 'annexa': 5, 'none': 1, 'iwfoamenabled': 9, 'annexdswitch': 7, 't1617d': 3, 'annexaswitch': 8, 'iwfoamdisabled': 10, 'lmi': 2, 'lmiswitch': 6, 't1617b': 4.
         wfFrSwL3NetAddress 1.3.6.1.4.1.18.3.5.9.6.1.1.6 ipaddress read-write
Indicates level 3 (IP) address of this frame relay interface
         wfFrSwDlcmiAddressLen 1.3.6.1.4.1.18.3.5.9.6.1.1.7 integer read-write
Indicates the address length, including the control portion. Enumeration: 'fourbyte': 4, 'threebyte': 3, 'twobyte': 2.
         wfFrSwDlcmiControlByteDisable 1.3.6.1.4.1.18.3.5.9.6.1.1.8 integer read-write
Indicates inclusion of control byte in q922 format. Enumeration: 'disabled': 2, 'enabled': 1.
         wfFrSwDlcmiPollingInterval 1.3.6.1.4.1.18.3.5.9.6.1.1.9 integer read-write
The number of seconds between successive status enquiry messages.
         wfFrSwDlcmiFullEnquiryInterval 1.3.6.1.4.1.18.3.5.9.6.1.1.10 integer read-write
Indicates the number of status enquiries before a full status enquiry. (For bidirectional procedures.)
         wfFrSwDlcmiErrorThreshold 1.3.6.1.4.1.18.3.5.9.6.1.1.11 integer read-write
Indicates the number errors monitored before declaring the interface down.
         wfFrSwDlcmiMonitoredEvents 1.3.6.1.4.1.18.3.5.9.6.1.1.12 integer read-write
Indicates the events over which error threshold is kept.
         wfFrSwDlcmiRecoveryCounts 1.3.6.1.4.1.18.3.5.9.6.1.1.13 integer read-only
Indicates the number of correct polling cycles during recovery.
         wfFrSwDlcmiMaxSupportedVCs 1.3.6.1.4.1.18.3.5.9.6.1.1.14 integer read-write
Indicates the maximum number of VCs allowed.
         wfFrSwDlcmiVCsInUse 1.3.6.1.4.1.18.3.5.9.6.1.1.15 integer read-only
Indicates the number of VCs that are currently configured on this interface.
         wfFrSwSwitchHdrErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.16 counter read-only
Indicates the number of frames dropped because they were received on the remote side with an invalid switch header.
         wfFrSwDlcmiSequenceCount 1.3.6.1.4.1.18.3.5.9.6.1.1.17 integer read-only
Indicates this switch's sequence counter; value of next to send.
         wfFrSwDlcmiLastReceived 1.3.6.1.4.1.18.3.5.9.6.1.1.18 integer read-only
Indicates the sequence number just received from the end station.
         wfFrSwDlcmiActiveSeqCount 1.3.6.1.4.1.18.3.5.9.6.1.1.19 integer read-only
Indicates the switch's sequence counter for sending status enquiry. (For bidirectional procedures.)
         wfFrSwDlcmiActiveReceived 1.3.6.1.4.1.18.3.5.9.6.1.1.20 integer read-only
Indicates the sequence number just received from the enquiring station. (For bidirectional procedures.)
         wfFrSwDlcmiPolls 1.3.6.1.4.1.18.3.5.9.6.1.1.21 counter read-only
This is the counter of where we are in the polling cycle.
         wfFrSwDlcmiAlarmTimer 1.3.6.1.4.1.18.3.5.9.6.1.1.22 integer read-only
Counter of 1/2 second timeouts. Indicates when to expect poll.
         wfFrSwErrType 1.3.6.1.4.1.18.3.5.9.6.1.1.23 integer read-only
Indicates the type of the last specific monitored error. Enumeration: 'reset': 1, 'short': 3, 'unknownie': 8, 'unknowndlci': 6, 'sequenceerr': 9, 'protoerr': 7, 'long': 4, 'illegaldlci': 5, 'other': 2, 'unknownrpt': 10, 'byteerr': 11, 'formaterr': 13, 'hdrerr': 12.
         wfFrSwErrData 1.3.6.1.4.1.18.3.5.9.6.1.1.24 octet string read-only
Contains as much of the error packet as possible.
         wfFrSwErrTime 1.3.6.1.4.1.18.3.5.9.6.1.1.25 timeticks read-only
Indicates the time the last error occurred.
         wfFrSwBcMeasurementInterval 1.3.6.1.4.1.18.3.5.9.6.1.1.26 integer read-write
Indicates the Committed Burst sample window interval in msec
         wfFrSwDlcmiMcastNoBufferErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.27 counter read-only
Indicates the number of times a multicast failed partially or wholly because there are insufficient buffers available to create multiple copies of a multicast frame
         wfFrSwDlcmiFrameTooShortErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.28 counter read-only
Indicates the number of frames dropped that are too short to be accepted.
         wfFrSwDlcmiFrameTooLongErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.29 counter read-only
Indicates the number of frames dropped that are too long to be accepted.
         wfFrSwDlcmiIllegalDlciErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.30 counter read-only
Indicates the number of frames dropped that had an invalid DLCI value.
         wfFrSwDlcmiUnknownDlciErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.31 counter read-only
Indicates the number of frames dropped which had an unknown DLCI value.
         wfFrSwDlcmiProtocolErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.32 counter read-only
Indicates the number of frames dropped because of a DLCMI protocol violation.
         wfFrSwDlcmiUnknownIEErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.33 counter read-only
Indicates the number of frames dropped that had an unknown information element.
         wfFrSwDlcmiSequenceErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.34 counter read-only
Indicates the number of frames dropped because of a DLCMI sequence error.
         wfFrSwDlcmiUnknownRPTErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.35 counter read-only
Indicates the number of frames dropped which had an unknown report type.
         wfFrSwDlcmiControlByteErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.36 counter read-only
Indicates the number of frames dropped that had an unsupported control byte.
         wfFrSwDlcmiFormatErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.37 counter read-only
Indicates the number of frames dropped due to a frame format error.
         wfFrSwDlcmiOtherErrors 1.3.6.1.4.1.18.3.5.9.6.1.1.38 counter read-only
Indicates the number of frames dropped due to unknown or other errors not counted by any error counter.
         wfFrSwDlcmiStatus 1.3.6.1.4.1.18.3.5.9.6.1.1.39 integer read-only
Indicates which state of execution the DLCMI gate is in Enumeration: 'fault': 3, 'running': 1, 'recovered': 2, 'start': 4.
         wfFrSwDlcmiNewVCs 1.3.6.1.4.1.18.3.5.9.6.1.1.40 counter read-only
Indicates the number of newly added PVCs that we have not yet told the CPE about, by means of a full-status message.
         wfFrSwDlcmiDeletedVCs 1.3.6.1.4.1.18.3.5.9.6.1.1.41 counter read-only
Indicates the number of deletedly added PVCs that we have not yet told the CPE about, by means of a full-status message.
         wfFrSwDlcmiFullStatusSeq 1.3.6.1.4.1.18.3.5.9.6.1.1.42 counter read-only
Indicates the expected sequence number for the next Status Enquiry message that will prove that the CPE received our last Full Status Message and knows about the deleted PVCs.
         wfFrSwDlcmiBidirect 1.3.6.1.4.1.18.3.5.9.6.1.1.43 integer read-write
Indication to delete this frame relay interface. Enumeration: 'enable': 1, 'disable': 2.
         wfFrSwDlcmiDteStatus 1.3.6.1.4.1.18.3.5.9.6.1.1.44 integer read-only
Indicates which state of execution the DLCMI gate is in for bidirectional procedures. Enumeration: 'fault': 3, 'running': 1, 'recovered': 2, 'start': 4.
         wfFrSwDlcmiDteSeqCount 1.3.6.1.4.1.18.3.5.9.6.1.1.45 integer read-only
Indicates the switch's sequence counter for sending status enquiry. (For bidirectional procedures.)
         wfFrSwDlcmiDteReceived 1.3.6.1.4.1.18.3.5.9.6.1.1.46 integer read-only
Indicates the sequence number just received from the enquiring station. (For bidirectional procedures.)
         wfFrSwDlcmiDteLastReceived 1.3.6.1.4.1.18.3.5.9.6.1.1.47 integer read-only
Indicates the sequence number just received from the end station.
         wfFrSwDlcmiDtePolls 1.3.6.1.4.1.18.3.5.9.6.1.1.48 counter read-only
This is the counter of where we are in the polling cycle.
         wfFrSwDlcmiDtePollingInterval 1.3.6.1.4.1.18.3.5.9.6.1.1.49 integer read-write
The number of seconds between successive status enquiry messages.
         wfFrSwDlcmiDteFullEnquiryInterval 1.3.6.1.4.1.18.3.5.9.6.1.1.50 integer read-write
Indicates the number of status enquiries before a full status enquiry. (For bidirectional procedures.)
         wfFrSwDlcmiDteErrorThreshold 1.3.6.1.4.1.18.3.5.9.6.1.1.51 integer read-write
Indicates the number errors monitored before declaring the interface down.
         wfFrSwDlcmiCrossNetEnable 1.3.6.1.4.1.18.3.5.9.6.1.1.52 integer read-write
Indication to delete this frame relay interface. Enumeration: 'enable': 1, 'disable': 2.
         wfFrSwDlcmiCrossNetPollingInterval 1.3.6.1.4.1.18.3.5.9.6.1.1.53 integer read-write
The number of seconds between successive status enquiry messages.
         wfFrSwDlcmiCrossNetErrorThreshold 1.3.6.1.4.1.18.3.5.9.6.1.1.54 integer read-write
Indicates the number missed heartbeat polls before declaring the cross-net PVC inactive.
         wfFrSwDlcmiCrossNetAsyncUpdateEnable 1.3.6.1.4.1.18.3.5.9.6.1.1.55 integer read-write
Indicates whether we are to send to the other end of the network, status updates for dlcis as soon as there is a change of status for the dlci. Enumeration: 'disabled': 2, 'enabled': 1.
         wfFrSwDlcmiBcMeasurementEnable 1.3.6.1.4.1.18.3.5.9.6.1.1.56 integer read-write
Indicates whether Committed Burst Measurement is enabled for this interface. If this attribute is set to DISABLE then DE bit setting in Frame Relay frames at this interface is disabled. Enumeration: 'enable': 1, 'disable': 2.
         wfFrSwDlcmiAsyncUpdateEnable 1.3.6.1.4.1.18.3.5.9.6.1.1.57 integer read-write
Indicates whether the link management entity should send an asynchronous single PVC update message when the state of a PVC is changed by a technician or by cross-net polling procedures. Enumeration: 'disabled': 2, 'enabled': 1.
         wfFrSwDlcmiCrossNetListenEnable 1.3.6.1.4.1.18.3.5.9.6.1.1.58 integer read-write
Indicates whether the link management entity should make a judgement of the PVC's status based on Cross Net updates. Enumeration: 'disabled': 2, 'enabled': 1.
         wfFrSwDlcmiSvcDisable 1.3.6.1.4.1.18.3.5.9.6.1.1.59 integer read-write
Indicates whether SVC is enabled or disabled for this access channel. Enumeration: 'disabled': 2, 'enabled': 1.
         wfFrSwDlcmiL2AddrType 1.3.6.1.4.1.18.3.5.9.6.1.1.60 integer read-write
Indicates the address type supported on this access channel. This information is needed when wFrSwDlcmiSVCDisable is enabled. Enumeration: 'e164': 1, 'x121': 2.
         wfFrSwDlcmiEscapeMode 1.3.6.1.4.1.18.3.5.9.6.1.1.61 integer read-write
Identifies the Escape mode (none, ingress or egress) to be used for PVCs with wfFrSwVcEscapeMode set to enabled. Enumeration: 'disabled': 1, 'ingress': 2, 'egress': 3.
         wfFrSwDlcmiEscapeCircuit 1.3.6.1.4.1.18.3.5.9.6.1.1.62 integer read-write
Identifies the FR-DTE circuit number corresponding to an Escape PVC. Applies only to PVCs with wfFrSwVcEscapeEnable set to enabled.
         wfFrSwDlcmiEscapeVcCount 1.3.6.1.4.1.18.3.5.9.6.1.1.63 integer read-write
The number of PVCs on this DLCMI that are configured as Escape VCs
         wfFrSwDlcmiIwfMode 1.3.6.1.4.1.18.3.5.9.6.1.1.64 integer read-write
Identifies the interworking mode (none, SDLC-to-FRSW) to be used for PVCs with wfFrSwVcEscapeMode set to enabled. Enumeration: 'none': 1, 'sdlc2frsw': 2.
         wfFrSwDlcmiSvcBillingEnable 1.3.6.1.4.1.18.3.5.9.6.1.1.65 integer read-write
Indicates whether the SVC Billing on this access channel set to enable. Enumeration: 'disabled': 2, 'enabled': 1.
         wfFrSwDlcmiSpvcAgent 1.3.6.1.4.1.18.3.5.9.6.1.1.66 integer read-write
Indicates if an SPVC Call Request Agent, Call Accept Agent, or both are enabled on this FRSW circuit. Enumeration: 'none': 1, 'cra': 2, 'caa': 3, 'craandcaa': 4.
         wfFrSwDlcmiCallAccDlciSelectionType 1.3.6.1.4.1.18.3.5.9.6.1.1.67 integer read-write
Indicates to the Call Accept Agent to accept SPVC Call Setup requests for any available DLCI or for a specific DLCI. Call Setup requests with the wrong selection type will be rejected. Enumeration: 'specific': 2, 'any': 1.
 wfFrSwCctTable 1.3.6.1.4.1.18.3.5.9.6.2 no-access
Frame Relay Circuit table gives information about a virtual circuit.
     wfFrSwCctEntry 1.3.6.1.4.1.18.3.5.9.6.2.1 no-access
An entry in the Frame Relay (Virtual) Circuit table.
         wfFrSwCctDelete 1.3.6.1.4.1.18.3.5.9.6.2.1.1 integer read-write
Indication to delete this frame relay interface. Enumeration: 'deleted': 2, 'system': 3, 'created': 1.
         wfFrSwCctNumber 1.3.6.1.4.1.18.3.5.9.6.2.1.2 integer read-only
Instance identifier; the circuit number of this interface.
         wfFrSwCctDlci 1.3.6.1.4.1.18.3.5.9.6.2.1.3 integer read-only
Instance identifier; this indicates the virtual circuit identifier Enumeration: 'fourbyteminimum': 131072, 'threebyteminimum': 1024, 'twobytemaximum': 1007, 'threebytemaximum': 64511, 'fourbytemaximum': 8257535, 'twobyteminimum': 16.
         wfFrSwCctState 1.3.6.1.4.1.18.3.5.9.6.2.1.4 integer read-only
Indicates whether the particular virtual circuit is operational. Enumeration: 'active': 2, 'control': 4, 'inactive': 3, 'user': 5, 'invalid': 1.
         wfFrSwCctMulticast 1.3.6.1.4.1.18.3.5.9.6.2.1.5 integer read-write
Indicates whether this dlci is used for multicast or single destination. Enumeration: 'unicast': 2, 'multicast': 1.
         wfFrSwCctInBc 1.3.6.1.4.1.18.3.5.9.6.2.1.6 integer read-only
Indicates the Incoming Committed Burst bits for this virtual circuit.
         wfFrSwCctOutBc 1.3.6.1.4.1.18.3.5.9.6.2.1.7 integer read-only
Indicates the Outgoing Committed Burst bits for this virtual circuit.
         wfFrSwCctInBe 1.3.6.1.4.1.18.3.5.9.6.2.1.8 integer read-write
Indicates the Incoming Excess Burst bits for this virtual circuit.
         wfFrSwCctOutBe 1.3.6.1.4.1.18.3.5.9.6.2.1.9 integer read-write
Indicates the Outgoing Excess Burst bits for this virtual circuit.
         wfFrSwCctInThroughput 1.3.6.1.4.1.18.3.5.9.6.2.1.10 integer read-write
Indicates the incoming throughput in bits/sec for this virtual circuit.
         wfFrSwCctOutThroughput 1.3.6.1.4.1.18.3.5.9.6.2.1.11 integer read-write
Indicates the outgoing throughput in bits/sec for this virtual circuit.
         wfFrSwCctCreationTime 1.3.6.1.4.1.18.3.5.9.6.2.1.12 timeticks read-only
Indicates the value of sysUpTime when the VC was created.
         wfFrSwCctLastTimeChange 1.3.6.1.4.1.18.3.5.9.6.2.1.13 timeticks read-only
Indicates the value of sysUpTime when last there was a change in VC state.
         wfFrSwCctLocalSentNonDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.14 counter read-only
Indicates the number of frames without the DE bit sent on this virtual circuit over the local interface.
         wfFrSwCctLocalSentNonDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.15 counter read-only
Indicates the number of octets without DE bit sent on this virtual circuit over the local interface.
         wfFrSwCctLocalSentDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.16 counter read-only
Indicates the number of frames with DE bit set sent on this virtual circuit over the local interface.
         wfFrSwCctLocalSentDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.17 counter read-only
Indicates the number of octets with DE bit set sent on this virtual circuit over the local interface.
         wfFrSwCctLocalSetFECNFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.18 counter read-only
Indicates the number of frames sent to the local interface on which this switch set the FECN bit .
         wfFrSwCctLocalSetFECNOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.19 counter read-only
Indicates the number of octets in frames sent to the local interface on which this switch set the FECN bit.
         wfFrSwCctLocalSetBECNFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.20 counter read-only
Indicates the number of frames sent to the local interface on which this switch set the BECN bit.
         wfFrSwCctLocalSetBECNOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.21 counter read-only
Indicates the number of octets in frames sent to the local interface on which this switch set the BECN bit.
         wfFrSwCctLocalSetDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.22 counter read-only
Indicates the number of frames sent to the local interface on which this switch set the DE bit.
         wfFrSwCctLocalSetDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.23 counter read-only
Indicates the number of octets in frames sent to the local interface on which this switch set the DE bit.
         wfFrSwCctLocalDropNonDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.24 counter read-only
Indicates the number of frames received over the local interface which were discarded, excluding any frames with the DE bit set.
         wfFrSwCctLocalDropNonDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.25 counter read-only
Indicates the number of octets in frames received over the local interface which were discarded, excluding any frames with the DE bit set.
         wfFrSwCctLocalDropDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.26 counter read-only
Indicates the number of frames received over the local interface, having the DE bit set, which were discarded.
         wfFrSwCctLocalDropDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.27 counter read-only
Indicates the number of octets in frames received over the local interface, having the DE bit set, which were discarded.
         wfFrSwCctInactiveVCDropFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.28 counter read-only
Indicates how many frames were discarded because the virtual circuit was inactive.
         wfFrSwCctInactiveVCDropOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.29 counter read-only
Indicates how many Octets were discarded because the virtual circuit was inactive.
         wfFrSwCctLocalRecvNonDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.30 counter read-only
Indicates the number of frames received on this virtual circuit over the local interface.
         wfFrSwCctLocalRecvNonDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.31 counter read-only
Indicates the number of octets received on this virtual circuit over the local interface.
         wfFrSwCctLocalRecvDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.32 counter read-only
Indicates the number of frames received over the local interface with the DE bit set.
         wfFrSwCctLocalRecvDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.33 counter read-only
Indicates the number of octets in frames received over the local interface with the DE bit set.
         wfFrSwCctLocalRecvFECNFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.34 counter read-only
Indicates the number of frames received over the local interface with the FECN bit set.
         wfFrSwCctLocalRecvFECNOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.35 counter read-only
Indicates the number of octets in frames received over the local interface with the FECN bit set.
         wfFrSwCctLocalRecvBECNFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.36 counter read-only
Indicates the number of frames received over the local interface with the BECN bit set.
         wfFrSwCctLocalRecvBECNOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.37 counter read-only
Indicates the number of octets in frames received over the local interface with the BECN bit set.
         wfFrSwCctLocalRecentNonDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.38 counter read-only
Indicates the number of octets received over the local interface during the most recent sampling period.
         wfFrSwCctRemoteSentNonDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.39 counter read-only
Indicates the number of Non DE set frames sent over the remote interface.
         wfFrSwCctRemoteSentNonDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.40 counter read-only
Indicates the number of Non DE set octets sent over the remote interface.
         wfFrSwCctRemoteSentDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.41 counter read-only
Indicates the number of DE set frames sent over the remote interface.
         wfFrSwCctRemoteSentDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.42 counter read-only
Indicates the number of DE set octets sent over the remote interface.
         wfFrSwCctRemoteSetFECNFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.43 counter read-only
Indicates the number of frames sent to the remote interface on which this switch set the FECN bit.
         wfFrSwCctRemoteSetFECNOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.44 counter read-only
Indicates the number of octets in frames sent to the remote interface that on which this switch set the FECN bit.
         wfFrSwCctRemoteSetBECNFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.45 counter read-only
Indicates the number of frames sent to the remote interface on which this switch set the BECN bit.
         wfFrSwCctRemoteSetBECNOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.46 counter read-only
Indicates the number of octets in frames sent to the remote interface on which this switch set the BECN bit.
         wfFrSwCctRemoteDropNonDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.47 counter read-only
Indicates the number of frames received over the remote interface which were discarded, excluding any frames with the DE bit set.
         wfFrSwCctRemoteDropNonDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.48 counter read-only
Indicates the number of octets in frames received over the remote interface which were discarded, excluding any frames with the DE bit set.
         wfFrSwCctRemoteDropDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.49 counter read-only
Indicates the number of frames received over the remote interface, having the DE bit set, which were discarded.
         wfFrSwCctRemoteDropDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.50 counter read-only
Indicates the number of octets in frames received over the remote interface, having the DE bit set, which were discarded.
         wfFrSwCctRemoteRecvNonDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.51 counter read-only
Indicates the number of frames received on this virtual circuit over the remote interface.
         wfFrSwCctRemoteRecvNonDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.52 counter read-only
Indicates the number of octets received on this virtual circuit over the remote interface.
         wfFrSwCctRemoteRecvDEFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.53 counter read-only
Indicates the number of frames received over the remote interface with the DE bit set.
         wfFrSwCctRemoteRecvDEOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.54 counter read-only
Indicates the number of octets in frames received over the remote interface with the DE bit set.
         wfFrSwCctRemoteRecvFECNFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.55 counter read-only
Indicates the number of frames received over the remote interface with the FECN bit set.
         wfFrSwCctRemoteRecvFECNOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.56 counter read-only
Indicates the number of octets in frames received over the remote interface with the FECN bit set.
         wfFrSwCctRemoteRecvBECNFrames 1.3.6.1.4.1.18.3.5.9.6.2.1.57 counter read-only
Indicates the number of frames received over the remote interface with the BECN bit set.
         wfFrSwCctRemoteRecvBECNOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.58 counter read-only
Indicates the number of octets in frames received over the remote interface with the BECN bit set.
         wfFrSwCctLocalBecnState 1.3.6.1.4.1.18.3.5.9.6.2.1.59 integer read-only
Indicates the local BECN state
         wfFrSwCctRemoteBecnState 1.3.6.1.4.1.18.3.5.9.6.2.1.60 integer read-only
Indicates the remote BECN state
         wfFrSwCctLocalOrRemoteConnection 1.3.6.1.4.1.18.3.5.9.6.2.1.61 integer read-only
Indicates whether this connection is Local to Local Connection or Local to Remote connection. Enumeration: 'remote': 2, 'local': 1.
         wfFrSwCctInBcOctets 1.3.6.1.4.1.18.3.5.9.6.2.1.62 integer read-only
Indicates the Incoming Committed Burst in octets for this virtual circuit.
         wfFrSwCctStateSet 1.3.6.1.4.1.18.3.5.9.6.2.1.63 integer read-write
User access for setting the state of a virtual circuit Enumeration: 'active': 2, 'inactive': 1.
         wfFrSwCctReportedStatus 1.3.6.1.4.1.18.3.5.9.6.2.1.64 integer read-only
Record keeping for circuit status Enumeration: 'unacked': 2, 'acked': 1, 'unreported': 3.
         wfFrSwCctReceivedStatus 1.3.6.1.4.1.18.3.5.9.6.2.1.65 integer read-only
State of a virtual circuit as reported by the network at an NNI Enumeration: 'active': 2, 'inactive': 1.
         wfFrSwCctCrossNetStatus 1.3.6.1.4.1.18.3.5.9.6.2.1.66 integer read-only
State of a virtual circuit as reported by the other end of the network under bidirectional signalling. Enumeration: 'active': 2, 'inactive': 1.
         wfFrSwCctXNetSent 1.3.6.1.4.1.18.3.5.9.6.2.1.67 integer read-only
Whether we have sent a cross net status message for this VC yet. Enumeration: 'unsent': 1, 'sent': 2.
         wfFrSwCctXNetReceived 1.3.6.1.4.1.18.3.5.9.6.2.1.68 integer read-only
Whether we have received a cross net status message for this VC during the current polling interval. Enumeration: 'unrecv': 2, 'recv': 1.
         wfFrSwCctXNetErrors 1.3.6.1.4.1.18.3.5.9.6.2.1.69 counter read-only
This is the count of the consecutive errors (usually timeouts) against this VC in cross-network heartbeat polling
 wfFrSwTupleTable 1.3.6.1.4.1.18.3.5.9.6.3 no-access
The Parameters for the Tuple table, identifying the endpoints of virtual circuits as pairs of IP addresses and DLCI.
     wfFrSwTupleEntry 1.3.6.1.4.1.18.3.5.9.6.3.1 no-access
The parameters for a particular Tuple.
         wfFrSwTupleDelete 1.3.6.1.4.1.18.3.5.9.6.3.1.1 integer read-write
Indication to delete this tuple. Enumeration: 'deleted': 2, 'created': 1.
         wfFrSwTupleIpAddrA 1.3.6.1.4.1.18.3.5.9.6.3.1.2 ipaddress read-only
Instance indentifier; indicates the IP address associated with endpoint 'A' of a virtual circuit.
         wfFrSwTupleDlciA 1.3.6.1.4.1.18.3.5.9.6.3.1.3 integer read-only
Instance identfier; indicates the DLCI associated with endpoint 'A' of a virtual circuit.
         wfFrSwTupleIpAddrB 1.3.6.1.4.1.18.3.5.9.6.3.1.4 ipaddress read-only
Instance identfier; indicates the IP address associated with endpoint 'B' of a virtual circuit.
         wfFrSwTupleDlciB 1.3.6.1.4.1.18.3.5.9.6.3.1.5 integer read-only
Instance identifier; Indicates the DLCI associated with endpoint 'B' of a virtual circuit.
 wfFrSwMcastTable 1.3.6.1.4.1.18.3.5.9.6.4 no-access
The list of multicast addresses
     wfFrSwMcastEntry 1.3.6.1.4.1.18.3.5.9.6.4.1 no-access
The parameters for a particular Multicast address.
         wfFrSwMcastDelete 1.3.6.1.4.1.18.3.5.9.6.4.1.1 integer read-write
Indication to delete this multicast instance. Enumeration: 'deleted': 2, 'created': 1.
         wfFrSwMcastIndex 1.3.6.1.4.1.18.3.5.9.6.4.1.2 integer read-only
Index of this multicast DLCI instance
         wfFrSwMcastIpAddr 1.3.6.1.4.1.18.3.5.9.6.4.1.3 ipaddress read-write
IP address of the interface in which this multicast DLCI is defined.
         wfFrSwMcastDlci 1.3.6.1.4.1.18.3.5.9.6.4.1.4 integer read-write
Identifies the multicast DLCI with which the IndividualDlci is associated.
         wfFrSwMcastIndividualDlci 1.3.6.1.4.1.18.3.5.9.6.4.1.5 integer read-write
Indicates the DLCI associated with the above multicast DLCI.
 wfFrSwUsage 1.3.6.1.4.1.18.3.5.9.6.5
     wfFrSwUsageEnable 1.3.6.1.4.1.18.3.5.9.6.5.1 integer read-write
Enable/Disable FRSW billing. Enumeration: 'disabled': 2, 'enabled': 1.
     wfFrSwUsageVolume 1.3.6.1.4.1.18.3.5.9.6.5.2 integer read-write
Indicates the file system volume number to which the billing usage data files will be written. The volume number corresponds to the slot number on which the volume resides. Note: Value 0 has the special meaning that no 'Store' and 'Flush' operations will take place. This translates to no Billing data will be written to the local file system. 'Update' operations will still be performed on each local slot. Full Billing statistics will still be available in the wfFrSwUsageTable MIB.
     wfFrSwUsageVolumeBackup 1.3.6.1.4.1.18.3.5.9.6.5.3 integer read-write
Indicates the backup volume if wfFrSwUsageVolume becomes inoperative. Note: This feature is not implemented in this release.
     wfFrSwUsageDirectory 1.3.6.1.4.1.18.3.5.9.6.5.4 displaystring read-write
The name of the directory where the billing usage data files are stored.
     wfFrSwUsageFilePrefix 1.3.6.1.4.1.18.3.5.9.6.5.5 displaystring read-write
The base name of billing usage data files.
     wfFrSwUsageTimerInterval 1.3.6.1.4.1.18.3.5.9.6.5.6 integer read-write
This number determines the timer interval (number of seconds) unit for the Billing process to perform its various timer driven tasks. i.e. updating billing usage data, writing billing usage data to file system and file system management activities.
     wfFrSwUsageUpdateInterval 1.3.6.1.4.1.18.3.5.9.6.5.7 integer read-write
This number specifies the interval (number of minutes) for the Billing process to collect and update billing usage data in the wfFrSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfFrSwUsageTimerInterval.
     wfFrSwUsageStoreInterval 1.3.6.1.4.1.18.3.5.9.6.5.8 integer read-write
This number specifies the interval (number of minutes) for the Billing process to write billing usage data on to the file system from the wfFrSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfFrSwUsageTimerInterval.
     wfFrSwUsageFlushInterval 1.3.6.1.4.1.18.3.5.9.6.5.9 integer read-write
This number specifies the interval (number of minutes) for the Billing process to write billing usage data on to the file system from the wfFrSwUsage MIB follow by zeroing the wfFrSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfFrSwUsageTimerInterval.
     wfFrSwUsageCleanupInterval 1.3.6.1.4.1.18.3.5.9.6.5.10 integer read-write
This is the interval (number of minutes) for the Billing process to check and delete old billing usage data files. Note: When converted to seconds, this must be a multilple of wfFrSwUsageTimerInterval.
     wfFrSwUsageLocalTimeZone 1.3.6.1.4.1.18.3.5.9.6.5.11 integer read-only
Indicates local time zone of the switch
     wfFrSwUsageUpdateTimeStamp 1.3.6.1.4.1.18.3.5.9.6.5.12 timeticks read-only
Time stamp of last wfFrSwUsageUpdateInterval timer expiration or the starting time of the current wfFrSwUsageUpdateInterval. This value is number of seconds since midnight Jan 1, 1976 (GMT).
     wfFrSwUsageStoreTimeStamp 1.3.6.1.4.1.18.3.5.9.6.5.13 timeticks read-only
Time stamp of last wfFrSwUsageStoreInterval timer expiration or the starting time of the current wfFrSwUsageStoreInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT).
     wfFrSwUsageFlushTimeStamp 1.3.6.1.4.1.18.3.5.9.6.5.14 timeticks read-only
Time stamp of last wfFrSwUsageFlushInterval timer expiration or the starting time of the current wfFrSwUsageFlushInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT).
     wfFrSwUsageCleanupTimeStamp 1.3.6.1.4.1.18.3.5.9.6.5.15 timeticks read-only
Time stamp of last wfFrSwUsageCleanupInterval timer expiration or the starting time of the current wfFrSwUsageCleanupInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT).
     wfFrSwUsageUpdateData 1.3.6.1.4.1.18.3.5.9.6.5.16 integer read-write
Setting this attribute to a non-zero value will cause an immediate updating of the billing usage data. Once activated, this attribute should be reset to zero to allow subsequent activations.
     wfFrSwUsageStoreData 1.3.6.1.4.1.18.3.5.9.6.5.17 integer read-write
Setting this attribute to a non-zero value will cause an immediate updating and writing of the billing usage data. Once activated, this attribute should be reset to zero to allow subsequent activations.
     wfFrSwUsageFlushData 1.3.6.1.4.1.18.3.5.9.6.5.18 integer read-write
Setting this attribute to a non-zero value will cause an immediate updating and writing of the billing usage data and followed by zeroing the wfFrSwBillingUsage MIB. Once activated, this attribute should be reset to zero to allow subsequent activations.
     wfFrSwUsageFileCleanup 1.3.6.1.4.1.18.3.5.9.6.5.19 integer read-write
Setting this attribute to a non-zero value will cause an immediate checking and deleting old billing usage data files. Once activated, this attribute should be reset to zero to allow subsequent activations.
     wfFrSwUsageState 1.3.6.1.4.1.18.3.5.9.6.5.20 integer read-only
current state FRSW billing. Enumeration: 'down': 2, 'init': 3, 'up': 1, 'notpresent': 4.
     wfFrSwUsageCurVolume 1.3.6.1.4.1.18.3.5.9.6.5.21 integer read-only
current file system volume number used. This number is the same as wfFrSwUsageVolume except when the user sets wfFrSwUsageVolume to an invalid number.
     wfFrSwUsageCurVolumeBackup 1.3.6.1.4.1.18.3.5.9.6.5.22 integer read-only
curent backup file system volume number used. This number is the same as wfFrSwUsageVolumeBackUp except when the user sets wfFrSwUsageVolume to an invalid number. Note: This feature is not implemented in this release.
     wfFrSwUsageCurDirectory 1.3.6.1.4.1.18.3.5.9.6.5.23 displaystring read-only
current directory name used. This number is the same as wfFrSwUsageDirectory except when the user sets wfFrSwUsageDirectory to an invalid name.
     wfFrSwUsageCurFilePrefix 1.3.6.1.4.1.18.3.5.9.6.5.24 displaystring read-only
current base file name used. This number is the same as wfFrSwUsageFilePrefix except when the user sets wfFrSwUsageFilePrefix to an invalid name.
     wfFrSwUsageCurTimerInterval 1.3.6.1.4.1.18.3.5.9.6.5.25 integer read-only
current timer interval number used. This number is the same as wfFrSwUsageTimerInterval except when the user sets wfFrSwUsageTimerInterval to an invalid value.
     wfFrSwUsageCurUpdateInterval 1.3.6.1.4.1.18.3.5.9.6.5.26 integer read-only
current update interval number used. This number is the same as wfFrSwUsageUpdateInterval except when the user sets wfFrSwUsageUpdateInterval to an invalid value.
     wfFrSwUsageCurStoreInterval 1.3.6.1.4.1.18.3.5.9.6.5.27 integer read-only
current store timer interval number used. This number is the same as wfFrSwUsageStoreInterval except when the user sets wfFrSwUsageStoreInterval to an invalid value.
     wfFrSwUsageCurFlushInterval 1.3.6.1.4.1.18.3.5.9.6.5.28 integer read-only
current flush timer interval number used. This number is the same as wfFrSwUsageFlushInterval except when the user sets wfFrSwUsageFlushInterval to an invalid value.
     wfFrSwUsageCurCleanupInterval 1.3.6.1.4.1.18.3.5.9.6.5.29 integer read-only
current file cleanup timer interval number used. This number is the same as wfFrSwUsageCleanupInterval except when the user sets wfFrSwUsageCleanupInterval to an invalid value.
     wfFrSwUsageDebug 1.3.6.1.4.1.18.3.5.9.6.5.30 integer read-write
Enable/Disable printing of debug edl (trap) messages. NOTE: Do not enable this attribute in operational enviornment as it will likely flood the logging facility. This attribute is reserved for specialized debugging in a controlled lab enviornment. Enumeration: 'disabled': 2, 'enabled': 1.
     wfFrSwUsageCurDebug 1.3.6.1.4.1.18.3.5.9.6.5.31 integer read-only
current debug value used. This value is the same as wfFrSwUsageDebug except when the user sets wfFrSwUsageDeubg to an invalid value. Enumeration: 'disabled': 2, 'enabled': 1.
     wfFrSwUsageSwitchId 1.3.6.1.4.1.18.3.5.9.6.5.32 integer read-only
switch id used in the billing usage data file.
     wfFrSwUsageNumEntries 1.3.6.1.4.1.18.3.5.9.6.5.33 integer read-only
number of entries in wfFrSwUsageTable
     wfFrSwSvcUsageEnable 1.3.6.1.4.1.18.3.5.9.6.5.34 integer read-write
Enable/Disable FRSW SVC billing. Enumeration: 'disabled': 2, 'enabled': 1.
     wfFrSwSvcUsageInterimRecordEnable 1.3.6.1.4.1.18.3.5.9.6.5.35 integer read-write
Enable/Disable Writing FRSW SVC billing record while SVC connection is still up. Enumeration: 'disabled': 2, 'enabled': 1.
     wfFrSwSvcUsageVolume 1.3.6.1.4.1.18.3.5.9.6.5.36 integer read-write
Indicates the file system volume number to which the SVC billing usage data files will be written. The volume number corresponds to the slot number on which the volume resides. Note: Value 0 has the special meaning that no 'Store' and 'Flush' operations will take place. This translates to no Billing data will be written to the local file system. 'Update' operations will still be performed on each local slot. Full Billing statistics will still be available in the wfFrSwUsageTable MIB.
     wfFrSwSvcUsageDirectory 1.3.6.1.4.1.18.3.5.9.6.5.37 displaystring read-write
The name of the directory where the SVC billing usage data files are stored.
     wfFrSwSvcUsageFilePrefix 1.3.6.1.4.1.18.3.5.9.6.5.38 displaystring read-write
The base name of SVC billing usage data files.
     wfFrSwSvcUsageUpdateInterval 1.3.6.1.4.1.18.3.5.9.6.5.39 integer read-write
This number specifies the interval (number of minutes) for the SVC Billing process to collect and update billing usage data in the wfFrSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfFrSwUsageTimerInterval.
     wfFrSwSvcUsageStoreInterval 1.3.6.1.4.1.18.3.5.9.6.5.40 integer read-write
This number specifies the interval (number of minutes) for the SVC Billing process to write billing usage data on to the file system from the wfFrSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfFrSwUsageTimerInterval.
     wfFrSwSvcUsageFlushInterval 1.3.6.1.4.1.18.3.5.9.6.5.41 integer read-write
This number specifies the interval (number of minutes) for the SVC Billing process to write billing usage data on to the file system from the wfFrSwUsage MIB follow by zeroing the wfFrSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfFrSwUsageTimerInterval.
     wfFrSwSvcUsageCleanupInterval 1.3.6.1.4.1.18.3.5.9.6.5.42 integer read-write
This is the interval (number of minutes) for the SVC Billing process to check and delete old billing usage data files. Note: When converted to seconds, this must be a multilple of wfFrSwUsageTimerInterval.
     wfFrSwSvcUsageUpdateTimeStamp 1.3.6.1.4.1.18.3.5.9.6.5.43 timeticks read-only
Time stamp of last wfFrSwSvcUsageUpdateInterval timer expiration or the starting time of the current wfFrSwSvcUsageUpdateInterval. This value is number of seconds since midnight Jan 1, 1976 (GMT).
     wfFrSwSvcUsageStoreTimeStamp 1.3.6.1.4.1.18.3.5.9.6.5.44 timeticks read-only
Time stamp of last wfFrSwSvcUsageStoreInterval timer expiration or the starting time of the current wfFrSwSvcUsageStoreInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT).
     wfFrSwSvcUsageFlushTimeStamp 1.3.6.1.4.1.18.3.5.9.6.5.45 timeticks read-only
Time stamp of last wfFrSwSvcUsageFlushInterval timer expiration or the starting time of the current wfFrSwSvcUsageFlushInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT).
     wfFrSwSvcUsageCleanupTimeStamp 1.3.6.1.4.1.18.3.5.9.6.5.46 timeticks read-only
Time stamp of last wfFrSwSvcUsageCleanupInterval timer expiration or the starting time of the current wfFrSwSvcUsageCleanupInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT).
     wfFrSwSvcUsageUpdateData 1.3.6.1.4.1.18.3.5.9.6.5.47 integer read-write
Setting this attribute to a non-zero value will cause an immediate updating of the SVC billing usage data. Once activated, this attribute should be reset to zero to allow subsequent activations.
     wfFrSwSvcUsageStoreData 1.3.6.1.4.1.18.3.5.9.6.5.48 integer read-write
Setting this attribute to a non-zero value will cause an immediate updating and writing of the SVC billing usage data. Once activated, this attribute should be reset to zero to allow subsequent activations.
     wfFrSwSvcUsageFlushData 1.3.6.1.4.1.18.3.5.9.6.5.49 integer read-write
Setting this attribute to a non-zero value will cause an immediate updating and writing of the SVC billing usage data and followed by zeroing the wfFrSwBillingUsage MIB. Once activated, this attribute should be reset to zero to allow subsequent activations.
     wfFrSwSvcUsageFileCleanup 1.3.6.1.4.1.18.3.5.9.6.5.50 integer read-write
Setting this attribute to a non-zero value will cause an immediate checking and deleting old SVC billing usage data files. Once activated, this attribute should be reset to zero to allow subsequent activations.
     wfFrSwSvcUsageState 1.3.6.1.4.1.18.3.5.9.6.5.51 integer read-only
current state FRSW SVC billing. Enumeration: 'down': 2, 'init': 3, 'up': 1, 'notpresent': 4.
     wfFrSwSvcUsageCurVolume 1.3.6.1.4.1.18.3.5.9.6.5.52 integer read-only
current file system volume number used for SVC Billing. This number is the same as wfFrSwSvcUsageVolume except when the user sets wfFrSwSvcUsageVolume to an invalid number.
     wfFrSwSvcUsageCurDirectory 1.3.6.1.4.1.18.3.5.9.6.5.53 displaystring read-only
current directory name used for SVC Billing. This number is the same as wfFrSwSvcUsageDirectory except when the user sets wfFrSwSvcUsageDirectory to an invalid name.
     wfFrSwSvcUsageCurFilePrefix 1.3.6.1.4.1.18.3.5.9.6.5.54 displaystring read-only
current base file name used for SVC Billing. This name is the same as wfFrSwSvcUsageFilePrefix except when the user sets wfFrSwSvcUsageFilePrefix to an invalid name.
     wfFrSwSvcUsageCurUpdateInterval 1.3.6.1.4.1.18.3.5.9.6.5.55 integer read-only
current update interval number used. This number is the same as wfFrSwSvcUsageUpdateInterval except when the user sets wfFrSwSvcUsageUpdateInterval to an invalid value.
     wfFrSwSvcUsageCurStoreInterval 1.3.6.1.4.1.18.3.5.9.6.5.56 integer read-only
current store timer interval number used. This number is the same as wfFrSwSvcUsageStoreInterval except when the user sets wfFrSwSvcUsageStoreInterval to an invalid value.
     wfFrSwSvcUsageCurFlushInterval 1.3.6.1.4.1.18.3.5.9.6.5.57 integer read-only
current flush timer interval number used. This number is the same as wfFrSwSvcUsageFlushInterval except when the user sets wfFrSwSvcUsageFlushInterval to an invalid value.
     wfFrSwSvcUsageCurCleanupInterval 1.3.6.1.4.1.18.3.5.9.6.5.58 integer read-only
current file cleanup timer interval number used. This number is the same as wfFrSwSvcUsageCleanupInterval except when the user sets wfFrSwSvcUsageCleanupInterval to an invalid value.
     wfFrSwSvcUsageNumEntries 1.3.6.1.4.1.18.3.5.9.6.5.59 integer read-only
number of entries in wfFrSwSvcUsageTable
     wfFrSwSvcUsageVersionId 1.3.6.1.4.1.18.3.5.9.6.5.60 integer read-only
The Software Version ID field is a two byte, right justified, binary formated value that identifies the particular version number of the software release. High nibble of byte 1 represents the major version number. Low nibble of byte 1 represents the release number. Byte 2 represents the integration number.
     wfFrSwUsageSwitchName 1.3.6.1.4.1.18.3.5.9.6.5.61 displaystring read-write
The Switch name is a 6-bytes, right justified with leading blanks as necessary. It can be combination of letters, numbers and blanks. This ID identifies the particular networks equipment for SVC billing usage data process.
     wfFrSwPvcUsageFileLayout 1.3.6.1.4.1.18.3.5.9.6.5.62 integer read-only
PVC usage file layout version
     wfFrSwSvcUsageFileLayout 1.3.6.1.4.1.18.3.5.9.6.5.63 integer read-only
SVC usage file layout version
 wfFrSwUsageTable 1.3.6.1.4.1.18.3.5.9.6.6 no-access
The Billing usage table.
     wfFrSwUsageEntry 1.3.6.1.4.1.18.3.5.9.6.6.1 no-access
The parameters for Billing Usage.
         wfFrSwUsageDelete 1.3.6.1.4.1.18.3.5.9.6.6.1.1 integer read-only
Indicates status of this entry. FRSW_USAGE_CREATED is the normal case. FRSW_USAGE_DELETED means the corresponding tuple and vc instances were deleted some time during this collection interval. This billing instance will be deleted at the end of the next wfFrSwUsageFlush period after this billing record is written out to the file system. Enumeration: 'deleted': 2, 'created': 1.
         wfFrSwUsageCircuitNumber 1.3.6.1.4.1.18.3.5.9.6.6.1.2 integer read-only
Instance identifier; the circuit number of this interface.
         wfFrSwUsageDlci 1.3.6.1.4.1.18.3.5.9.6.6.1.3 integer read-only
Instance identifier; this indicates which virtual circuit. Enumeration: 'fourbyteminimum': 131072, 'threebyteminimum': 1024, 'twobytemaximum': 1007, 'threebytemaximum': 64511, 'fourbytemaximum': 8257535, 'twobyteminimum': 16.
         wfFrSwUsageIPAddress 1.3.6.1.4.1.18.3.5.9.6.6.1.4 ipaddress read-only
(Local) IP address corresponding to wfFrSwUsageCircuitNumber of this virtual circuit.
         wfFrSwUsageStartTimeStampHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.5 integer read-only
Time stamp of the starting time (the high 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT).
         wfFrSwUsageStartTimeStampLow 1.3.6.1.4.1.18.3.5.9.6.6.1.6 integer read-only
Time stamp of the starting time (the low 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT).
         wfFrSwUsageEndTimeStampHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.7 integer read-only
Time stamp of the ending time (the high 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT).
         wfFrSwUsageEndTimeStampLow 1.3.6.1.4.1.18.3.5.9.6.6.1.8 integer read-only
Time stamp of the ending time (the low 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT).
         wfFrSwUsageSentNonDEFramesHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.9 integer read-only
Number (the high 32 bits) of local frames sent from this virtual circuit between wfFrSwUsageStartTimeStamp and wfFrSwUsageEndTimeStamp.
         wfFrSwUsageSentNonDEFramesLow 1.3.6.1.4.1.18.3.5.9.6.6.1.10 integer read-only
Number (the low 32 bits) of local frames sent from this virtual circuit between wfFrSwUsageStartTimeStamp and wfFrSwUsageEndTimeStamp.
         wfFrSwUsageSentNonDEOctetsHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.11 integer read-only
Number (the high 32 bits) of local octets sent from this virtual circuit between wfFrSwUsageStartTimeStamp and wfFrSwUsageEndTimeStamp.
         wfFrSwUsageSentNonDEOctetsLow 1.3.6.1.4.1.18.3.5.9.6.6.1.12 integer read-only
Number (the low 32 bits) of local octets sent from this virtual circuit between wfFrSwUsageStartTimeStamp and wfFrSwUsageEndTimeStamp.
         wfFrSwUsageSentDEFramesHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.13 integer read-only
Number (the high 32 bits) of local frames with DE bit sent from this virtual circuit between wfFrSwUsageStartTimeStamp and wfFrSwUsageEndTimeStamp.
         wfFrSwUsageSentDEFramesLow 1.3.6.1.4.1.18.3.5.9.6.6.1.14 integer read-only
Number (the low 32 bits) of local frames with DE bit sent from this virtual circuit between wfFrSwUsageStartTimeStamp and wfFrSwUsageEndTimeStamp.
         wfFrSwUsageSentDEOctetsHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.15 integer read-only
Number (the high 32 bits) of local octets with DE bit sent from this virtual circuit between wfFrSwUsageStartTimeStamp and wfFrSwUsageEndTimeStamp.
         wfFrSwUsageSentDEOctetsLow 1.3.6.1.4.1.18.3.5.9.6.6.1.16 integer read-only
Number (the low 32 bits) of local octets with DE bit sent from this virtual circuit between wfFrSwUsageStartTimeStamp and wfFrSwUsageEndTimeStamp.
         wfFrSwUsageLastNonDEFramesHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.17 integer read-only
The (high 32 bits) value of wfFrSwCctLocalSentNonDEFrames value at wfFrSwUsageEndTimeStamp. Note: Since wfFrSwCctLocalSentNonDEFrames is a 32-bit COUNTER, this is really a counter keeping track of number of times wfFrSwCctLocalSentNonDEFrames has wrapped around.
         wfFrSwUsageLastNonDEFramesLow 1.3.6.1.4.1.18.3.5.9.6.6.1.18 integer read-only
The (low 32 bits) value of wfFrSwCctLocalSentNonDEFrames value at wfFrSwUsageEndTimeStamp.
         wfFrSwUsageLastNonDEOctetsHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.19 integer read-only
The (high 32 bits) value of wfFrSwCctLocalSentNonDEOctets value at wfFrSwUsageEndTimeStamp. Note: Since wfFrSwCctLocalSentNonDEOctets is a 32-bit COUNTER, this is really a counter keeping track of number of times wfFrSwCctLocalSentNonDEOctets has wrapped around.
         wfFrSwUsageLastNonDEOctetsLow 1.3.6.1.4.1.18.3.5.9.6.6.1.20 integer read-only
The (low 32 bits) value of wfFrSwCctLocalSentNonDEOctets value at wfFrSwUsageEndTimeStamp.
         wfFrSwUsageLastDEFramesHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.21 integer read-only
The (high 32 bits) value of wfFrSwCctLocalSentDEFrames value at wfFrSwUsageEndTimeStamp. Note: Since wfFrSwCctLocalSentNonDEFrames is a 32-bit COUNTER, this is really a counter keeping track of number of times wfFrSwCctLocalSentDEFrames has wrapped around.
         wfFrSwUsageLastDEFramesLow 1.3.6.1.4.1.18.3.5.9.6.6.1.22 integer read-only
The (low 32 bits) value of wfFrSwCctLocalSentDEFrames value at wfFrSwUsageEndTimeStamp.
         wfFrSwUsageLastDEOctetsHigh 1.3.6.1.4.1.18.3.5.9.6.6.1.23 integer read-only
The (high 32 bits) value of wfFrSwCctLocalSentDEOctets value at wfFrSwUsageEndTimeStamp. Note: Since wfFrSwCctLocalSentDEOctets is a 32-bit COUNTER, this is really a counter keeping track of number of times wfFrSwCctLocalSentDEOctets has wrapped around.
         wfFrSwUsageLastDEOctetsLow 1.3.6.1.4.1.18.3.5.9.6.6.1.24 integer read-only
The (low 32 bits) value of wfFrSwCctLocalSentDEOctets value at wfFrSwUsageEndTimeStamp.
         wfFrSwUsageRemoteIPAddress 1.3.6.1.4.1.18.3.5.9.6.6.1.25 ipaddress read-only
IP address of the other side (remote) of this PVC endpoint.
         wfFrSwUsageRemoteDlci 1.3.6.1.4.1.18.3.5.9.6.6.1.26 integer read-only
DLCI number of the other side (remote) of this PVC endpoint. Enumeration: 'fourbyteminimum': 131072, 'threebyteminimum': 1024, 'twobytemaximum': 1007, 'threebytemaximum': 64511, 'fourbytemaximum': 8257535, 'twobyteminimum': 16.
 wfFrSwVcTable 1.3.6.1.4.1.18.3.5.9.6.7 no-access
Frame Relay Virtual Circuit table gives information about a virtual circuit.
     wfFrSwVcEntry 1.3.6.1.4.1.18.3.5.9.6.7.1 no-access
An entry in the Frame Relay (Virtual) Circuit table.
         wfFrSwVcDelete 1.3.6.1.4.1.18.3.5.9.6.7.1.1 integer read-write
Indication to delete this virtual circuit. Enumeration: 'spvccaa': 6, 'created': 1, 'deleted': 2, 'svc': 4, 'system': 3, 'spvccra': 5.
         wfFrSwVcCircuit 1.3.6.1.4.1.18.3.5.9.6.7.1.2 integer read-only
Instance identifier; the circuit number of this interface (logical port).
         wfFrSwVcDlci 1.3.6.1.4.1.18.3.5.9.6.7.1.3 integer read-only
Instance identifier; this indicates the virtual circuit identifier
         wfFrSwVcState 1.3.6.1.4.1.18.3.5.9.6.7.1.4 integer read-only
Indicates whether the particular virtual circuit is operational. Enumeration: 'active': 2, 'control': 4, 'inactive': 3, 'user': 5, 'invalid': 1.
         wfFrSwVcStateSet 1.3.6.1.4.1.18.3.5.9.6.7.1.5 integer read-write
User access for setting the state of a virtual circuit Enumeration: 'active': 2, 'inactive': 1.
         wfFrSwVcMulticast 1.3.6.1.4.1.18.3.5.9.6.7.1.6 integer read-write
Indicates whether this dlci is used for multicast or a single destination. Enumeration: 'unicast': 2, 'multicast': 1.
         wfFrSwVcInBe 1.3.6.1.4.1.18.3.5.9.6.7.1.7 integer read-only
Indicates the maximum number Incoming Excess Burst bits that are allowed in a configured time interval (T).
         wfFrSwVcOutBe 1.3.6.1.4.1.18.3.5.9.6.7.1.8 integer read-only
Indicates the Outgoing Excess Burst bits for this virtual circuit.
         wfFrSwVcInThroughput 1.3.6.1.4.1.18.3.5.9.6.7.1.9 integer read-write
Indicates the incoming throughput in bits/sec for this virtual circuit.
         wfFrSwVcOutThroughput 1.3.6.1.4.1.18.3.5.9.6.7.1.10 integer read-write
Indicates the outgoing throughput in bits/sec for this virtual circuit.
         wfFrSwVcOutBc 1.3.6.1.4.1.18.3.5.9.6.7.1.11 integer read-only
Indicates the Outgoing Committed Burst bits for this virtual circuit.
         wfFrSwVcInBc 1.3.6.1.4.1.18.3.5.9.6.7.1.12 integer read-only
Indicates the Incoming Committed Burst bits for this virtual circuit.
         wfFrSwVcInBcOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.13 integer read-only
Indicates the Incoming Committed Burst in octets for this virtual circuit.
         wfFrSwVcBecnState 1.3.6.1.4.1.18.3.5.9.6.7.1.14 integer read-only
Indicates the BECN state
         wfFrSwVcReportedStatus 1.3.6.1.4.1.18.3.5.9.6.7.1.15 integer read-only
Record keeping for circuit status Enumeration: 'unacked': 2, 'acked': 1, 'unreported': 3.
         wfFrSwVcReceivedStatus 1.3.6.1.4.1.18.3.5.9.6.7.1.16 integer read-only
State of a virtual circuit as reported by the network at an NNI Enumeration: 'active': 2, 'inactive': 1.
         wfFrSwVcCrossNetStatus 1.3.6.1.4.1.18.3.5.9.6.7.1.17 integer read-only
State of a virtual circuit as reported by the other end of the network under bidirectional signalling. Enumeration: 'active': 2, 'inactive': 1.
         wfFrSwVcXNetSent 1.3.6.1.4.1.18.3.5.9.6.7.1.18 integer read-only
Whether we have sent a cross net status message for this VC yet. Enumeration: 'unsent': 1, 'sent': 2.
         wfFrSwVcXNetReceived 1.3.6.1.4.1.18.3.5.9.6.7.1.19 integer read-only
Whether we have received a cross net status message for this VC during the current polling interval. Enumeration: 'unrecv': 2, 'recv': 1.
         wfFrSwVcCalledIpAddr 1.3.6.1.4.1.18.3.5.9.6.7.1.20 ipaddress read-write
Indicates the IP address associated with destination of a virtual circuit.
         wfFrSwVcCalledDlci 1.3.6.1.4.1.18.3.5.9.6.7.1.21 integer read-write
Indicates the DLCI associated with destination of a virtual circuit.
         wfFrSwVcTrfPriority 1.3.6.1.4.1.18.3.5.9.6.7.1.22 integer read-write
Defines the traffic priority level of all the incoming packets on this VC. FRSW_VCPRIORITY_DEFAULT - Set all incoming user traffic packets to the default priority used by the port. FRSW_VCPRIORITY_ONE - Set all incoming packets to priority 1. FRSW_VCPRIORITY_TWO - Set all incoming packets to priority 2. FRSW_VCPRIORITY_THREE - Set all incoming packets to priority 3. Priority 0 is reserved for network critical packets like OSPF, FR LMI and SMDS heartbeat and is not available for user traffic. Enumeration: 'default': 999, 'three': 3, 'two': 2, 'one': 1.
         wfFrSwVcCreationTime 1.3.6.1.4.1.18.3.5.9.6.7.1.23 timeticks read-only
Indicates the value of sysUpTime when the VC was created.
         wfFrSwVcLastTimeChange 1.3.6.1.4.1.18.3.5.9.6.7.1.24 timeticks read-only
Indicates the value of sysUpTime when last there was a change in VC state.
         wfFrSwVcTxNonDeFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.25 counter read-only
Indicates the number of frames without the DE bit sent on this virtual circuit over the interface.
         wfFrSwVcTxNonDeOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.26 counter read-only
Indicates the number of octets without DE bit sent on this virtual circuit over the interface.
         wfFrSwVcTxDeFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.27 counter read-only
Indicates the number of frames with DE bit set sent on this virtual circuit over the interface.
         wfFrSwVcTxDeOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.28 counter read-only
Indicates the number of octets with DE bit set sent on this virtual circuit over the interface.
         wfFrSwVcSetFecnFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.29 counter read-only
Indicates the number of frames sent to the interface on which this switch set the FECN bit.
         wfFrSwVcSetFecnOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.30 counter read-only
Indicates the number of octets in frames sent to the interface on which this switch set the FECN bit.
         wfFrSwVcSetBecnFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.31 counter read-only
Indicates the number of frames sent to the interface on which this switch set the BECN bit.
         wfFrSwVcSetBecnOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.32 counter read-only
Indicates the number of octets in frames sent to the interface on which this switch set the BECN bit.
         wfFrSwVcSetDeFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.33 counter read-only
Indicates the number of frames sent to the interface on which this switch set the DE bit.
         wfFrSwVcSetDeOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.34 counter read-only
Indicates the number of octets in frames sent to the interface on which this switch set the DE bit.
         wfFrSwVcDropNonDeFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.35 counter read-only
Indicates the number of frames received over the interface which were discarded, excluding any frames with the DE bit set.
         wfFrSwVcDropNonDeOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.36 counter read-only
Indicates the number of octets in frames received over the interface which were discarded, excluding any frames with the DE bit set.
         wfFrSwVcDropDeFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.37 counter read-only
Indicates the number of frames received over the interface, having the DE bit set, which were discarded.
         wfFrSwVcDropDeOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.38 counter read-only
Indicates the number of octets in frames received over the interface, having the DE bit set, which were discarded.
         wfFrSwVcInactiveVcDropFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.39 counter read-only
Indicates how many frames were discarded because the virtual circuit was inactive.
         wfFrSwVcInactiveVcDropOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.40 counter read-only
Indicates how many Octets were discarded because the virtual circuit was inactive.
         wfFrSwVcRecvNonDeFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.41 counter read-only
Indicates the number of frames received on this virtual circuit over the interface.
         wfFrSwVcRecvNonDeOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.42 counter read-only
Indicates the number of octets received on this virtual circuit over the interface.
         wfFrSwVcRecvDeFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.43 counter read-only
Indicates the number of frames received over the interface with the DE bit set.
         wfFrSwVcRecvDeOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.44 counter read-only
Indicates the number of octets in frames received over the interface with the DE bit set.
         wfFrSwVcRecvFecnFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.45 counter read-only
Indicates the number of frames received over the interface with the FECN bit set.
         wfFrSwVcRecvFecnOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.46 counter read-only
Indicates the number of octets in frames received over the interface with the FECN bit set.
         wfFrSwVcRecvBecnFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.47 counter read-only
Indicates the number of frames received over the interface with the BECN bit set.
         wfFrSwVcRecvBecnOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.48 counter read-only
Indicates the number of octets in frames received over the interface with the BECN bit set.
         wfFrSwVcRecentNonDeOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.49 counter read-only
Indicates the number of octets received over the interface during the most recent sampling period.
         wfFrSwVcXNetErrors 1.3.6.1.4.1.18.3.5.9.6.7.1.50 counter read-only
This is the count of the consecutive errors (usually timeouts) against this VC in cross-network heartbeat polling.
         wfFrSwVcDropExcessBurstFrames 1.3.6.1.4.1.18.3.5.9.6.7.1.51 counter read-only
Indicates the number of Excess Burst Frames dropped on this virtual circuit.
         wfFrSwVcDropExcessBurstOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.52 counter read-only
Indicates the number of Excess Burst Octets dropped on this virtual circuit.
         wfFrSwVcInBeOctets 1.3.6.1.4.1.18.3.5.9.6.7.1.53 integer read-only
Indicates the maximum number Incoming Excess Burst bytes that are allowed in a configured time interval (T).
         wfFrSwVcCfgInBe 1.3.6.1.4.1.18.3.5.9.6.7.1.54 integer read-write
The number of Excess Burst in bits
         wfFrSwVcRedirectAction 1.3.6.1.4.1.18.3.5.9.6.7.1.55 integer read-write
Perform pvc source redirect manually or based on cross-net updates: 'redirecttoprimary(2)' will force to switch to primary; 'redirecttobackup(3)' will force to switch to backup; 'switchondemand(4)' will switch based on cross-net status of the primary to and from primary; 'swondemandtoprimary(5)' will switch to primary from backup iff cross-net of primary became active; 'swondemandtobackup(6)' will switch to backup from primary iff cross-net of primary became inactive. Enumeration: 'redirecttobackup': 3, 'swondemandtoprimary': 5, 'switchondemand': 4, 'swondemandtobackup': 6, 'redirecttoprimary': 2.
         wfFrSwVcRedirectType 1.3.6.1.4.1.18.3.5.9.6.7.1.56 integer read-write
Type of dte notification at switching time: 'transparent(1)' will not send notification to dte; 'intrusiven(2)' will send async update with NEW bit; 'intrusivea(3)' will send async update with A bit not set. Enumeration: 'intrusivea': 3, 'transparent': 1, 'intrusiven': 2.
         wfFrSwVcRedirectState 1.3.6.1.4.1.18.3.5.9.6.7.1.57 integer read-only
PVC Source Redirect State: 'backupinactive(1)' - backup is not configured and/or cross-net status is inactive; will allow traffic only through primary. 'primaryactive(2)' - both primary and backup rx'ed 'active' cross-net status, currently primary is active and traffic only through primary. 'switchtobackup(3)' - primary cross-net status is inactive, but can not switch to backup due to manual (or semi-manual) operation of the redirect; will allow traffic only through primary. 'backupactive(12)' - cross-net status is 'inactive' for primary; will allow traffic only through backup. 'switchtoprimary(13)' - cross-net status is 'active' for primary, should by can not switch to primary due to manual (or semi-manual) operation of the redirect; will allow traffic only through backup. 'holddown(21)' - down state used as intermediate state at switching time (for not more then a second); all traffic is dropped. Enumeration: 'backupactive': 12, 'primaryactive': 2, 'holddown': 21, 'switchtobackup': 3, 'switchtoprimary': 13, 'backupinactive': 1.
         wfFrSwVcBackupCalledIpAddr 1.3.6.1.4.1.18.3.5.9.6.7.1.58 ipaddress read-write
Backup Called Ip Address of the remote end of the PVC.
         wfFrSwVcBackupCalledDlci 1.3.6.1.4.1.18.3.5.9.6.7.1.59 integer read-write
Backup Called Dlci of the remote end of the PVC.
         wfFrSwVcBackupCrossNetStatus 1.3.6.1.4.1.18.3.5.9.6.7.1.60 integer read-only
Cross net status of the backup remote end of the PVC. Enumeration: 'active': 2, 'inactive': 1.
         wfFrSwVcBackupCrossNetErrors 1.3.6.1.4.1.18.3.5.9.6.7.1.61 integer read-only
Support counter of missed cross net update from backup remote end of the PVC, range: [0, wfFrSwDlcmiCrossNetErrorThreshold].
         wfFrSwVcAtmIwfMode 1.3.6.1.4.1.18.3.5.9.6.7.1.62 integer read-write
This attribute indicates the mode of FR-ATM interworking over this FR PVC or that FR-ATM interworking is not enabled on it. Enumeration: 'atmServiceIwfTransparentMode': 2, 'atmNetworkIwfMode': 4, 'atmDisableIwfMode': 1, 'atmServiceIwfTranslationMode': 3.
         wfFrSwVcAtmIwfVPI 1.3.6.1.4.1.18.3.5.9.6.7.1.63 integer read-write
This is relevant only when the ATM/FR interworking is enabled for this PVC. This indicates the ATM virtual path identifier associated with the Frame Relay PVC described by this record virtual circuit identifier.
         wfFrSwVcAtmIwfVCI 1.3.6.1.4.1.18.3.5.9.6.7.1.64 integer read-write
This is relevant only when FR/ATM interworking is enabled for this PVC. This indicates the ATM virtual circuit identifier associated with the Frame Relay PVC described by this record.
         wfFrSwVcAtmIwfLossPriorityPolicy 1.3.6.1.4.1.18.3.5.9.6.7.1.65 integer read-write
This is relevant only when FR/ATM interworking is enabled for this FR PVC. This indicates the policy for translating ATM CLP to FR DE on this PVC or simply setting FR DE to a constant value for all frames. Enumeration: 'atmiwfmapDe': 1, 'atmiwfsetDe1': 2, 'atmiwfsetDe0': 3.
         wfFrSwVcAtmIwfDePolicy 1.3.6.1.4.1.18.3.5.9.6.7.1.66 integer read-write
This is relevant only when FR/ATM interworking is enabled for this FR PVC. This indicates the policy on this PVC for translating FR DE to ATM CLP or simply setting CLP to a constant value for all frames. Enumeration: 'atmiwfmapClp': 1, 'atmiwfsetClp0': 3, 'atmiwfsetClp1': 2.
         wfFrSwVcAtmIwfEfciPolicy 1.3.6.1.4.1.18.3.5.9.6.7.1.67 integer read-write
This is relevant only when FR/ATM interworking is enabled for this FR PVC. This indicates the policy on this PVC for translating FR FECN to ATM EFCI or simply setting ATM EFCI to a constant value for all frames. Enumeration: 'atmiwfsetFecn0': 3, 'atmiwfmapFecn': 1, 'atmiwfsetFecn1': 2.
         wfFrSwVcEscapeEnable 1.3.6.1.4.1.18.3.5.9.6.7.1.68 integer read-write
Identifies this PVC as either a standard FRSW PVC (escape disabled) or an Escape PVC (escape enabled). The type of Escape PVC (ingress node or egress node) is specified in the wfFrSwDlcmiEntry Object. Enumeration: 'disabled': 2, 'enabled': 1.
         wfFrSwVcSpvcCallState 1.3.6.1.4.1.18.3.5.9.6.7.1.69 integer read-only
Indicates to the state of the SPVC call for this DLCI. Enumeration: 'active': 3, 'inprogress': 2, 'inactive': 1.
         wfFrSwVcCallReqCalledAddr 1.3.6.1.4.1.18.3.5.9.6.7.1.70 displaystring read-write
Called E.164/X.121 Address for an SPVC Call Request Agent. The address type is determined by the wfFrSwDlcmiL2AddrType attribute in wfFrSwDlcmiEntry.
         wfFrSwVcCallReqDlciSelectionType 1.3.6.1.4.1.18.3.5.9.6.7.1.71 integer read-write
Indicates to the Calling End of an SPVC Call Request whether to use any available DLCI, or a specific DLCI. If 'specific' is chosen, the called DLCI value is specified in wfFrSwVcCallReqCalledDlci. Enumeration: 'specific': 2, 'any': 1.
         wfFrSwVcCallReqCalledDlci 1.3.6.1.4.1.18.3.5.9.6.7.1.72 integer read-write
Indicates to the Calling End of an SPVC Call Request the DLCI to be used at the destination of a virtual circuit. This value should be specified when 'specific' wfFrSwVcCallReqDlciSelectionType is chosen.
         wfFrSwVcCallReqRetryTimer 1.3.6.1.4.1.18.3.5.9.6.7.1.73 integer read-write
Indicates the number of minutes the Call Request Agent should wait for an SPVC CONNECT message before declaring a Call Setup request REJECTED.
         wfFrSwVcCallReqMaxRetries 1.3.6.1.4.1.18.3.5.9.6.7.1.74 integer read-write
Indicates the number of times the Call Request Agent should retry failed Call Setup requests before declaring the SPVC invalid.
 wfFrSwIsdnBaseTable 1.3.6.1.4.1.18.3.5.9.6.8 no-access
This is a FRSW over ISDN configuration table. This table specifies whether the Calling Party (ANI) or Called Party (DNIS) ISDN Phone Number should be used to map the ISDN call to a particular FRSW UNI. The table is indexed by the Slot Number where the PRI(s) exist.
     wfFrSwIsdnBaseEntry 1.3.6.1.4.1.18.3.5.9.6.8.1 no-access
Instance Id for this table.
         wfFrSwIsdnBaseDelete 1.3.6.1.4.1.18.3.5.9.6.8.1.1 integer read-write
Indication to delete this FRSW ISDN interface. Enumeration: 'deleted': 2, 'created': 1.
         wfFrSwIsdnBaseSlotNum 1.3.6.1.4.1.18.3.5.9.6.8.1.2 integer read-only
This number is the Slot Number for the PRI interface(s) that are being configured for FRSW ISDN. There will be one of these tables for every slot where an FRSW ISDN PRI Interface exists.
         wfFrSwIsdnBaseAssocType 1.3.6.1.4.1.18.3.5.9.6.8.1.3 integer read-write
Indicates which ISDN Phone Number (ANI or DNIS) to use to do the ISDN call to FRSW UNI mapping. Enumeration: 'dnis': 1, 'ani': 2.
 wfFrSwIsdnAssocTable 1.3.6.1.4.1.18.3.5.9.6.9 no-access
This table defines the Association Table to be used for the FRSW over ISDN application. The table contains a list of ISDN Phone Numbers and the associated FRSW UNI Index Number. The table is indexed by the Slot Number and the ISDN Phone Number.
     wfFrSwIsdnAssocEntry 1.3.6.1.4.1.18.3.5.9.6.9.1 no-access
Instance Id for this table.
         wfFrSwIsdnAssocDelete 1.3.6.1.4.1.18.3.5.9.6.9.1.1 integer read-write
Indication to delete this Association Instance. Enumeration: 'deleted': 2, 'created': 1.
         wfFrSwIsdnAssocSlotNum 1.3.6.1.4.1.18.3.5.9.6.9.1.2 integer read-only
Slot with which this ISDN Phone Number is associated.
         wfFrSwIsdnAssocNum 1.3.6.1.4.1.18.3.5.9.6.9.1.3 octet string read-only
ISDN Phone Number that is used to look up the appropriate FRSW UNI Index. This number is compared with either the Calling Party Number (ANI) Information Element or the Called Party Number (DNIS) Information Element contained in the ISDN Call Setup Message.
         wfFrSwIsdnAssocScrnEnable 1.3.6.1.4.1.18.3.5.9.6.9.1.4 integer read-write
Indicate whether allowed screening should be enabled or disabled for all of the UNIs contained in the FRSW UNI Index. Enumeration: 'disabled': 2, 'enabled': 1.
         wfFrSwIsdnAssocIndex 1.3.6.1.4.1.18.3.5.9.6.9.1.5 integer read-write
A number that indicates the FRSW UNI Index that is is associated with the ISDN Phone Number. This FRSW UNI Index is used as a key to obtain the UNIs and the Screening information from the wfFrSwIsdnScrnEntry and wfFrSwIsdnUniEntry mibs. The default for the index is 2**31 - 1 = 2147483647 = 0x7FFFFFFF, which represents an unconfigured index number.
 wfFrSwIsdnUniTable 1.3.6.1.4.1.18.3.5.9.6.10 no-access
This table is used by the FRSW over ISDN application. The table defines a list of FRSW UNIs that are to be collected into a hunt group identifiable by an Index Number.
       wfFrSwIsdnUniEntry 1.3.6.1.4.1.18.3.5.9.6.10.1 no-access
Instance Id for this table.
           wfFrSwIsdnUniDelete 1.3.6.1.4.1.18.3.5.9.6.10.1.1 integer read-write
Indication to delete this FRSW UNI Index Instance. Enumeration: 'deleted': 2, 'created': 1.
           wfFrSwIsdnUniIndex 1.3.6.1.4.1.18.3.5.9.6.10.1.2 integer read-only
FRSW UNI Index -- a number that identifies a group of related FRSW UNIs that are collected together as a hunt group. This number ties this entry to an entry in wfFrSwIsdnAssocEntry.
           wfFrSwIsdnUniNum 1.3.6.1.4.1.18.3.5.9.6.10.1.3 integer read-only
A FRSW UNI/Circuit.
           wfFrSwIsdnUniState 1.3.6.1.4.1.18.3.5.9.6.10.1.4 integer read-only
State of this UNI (available or in-use). Enumeration: 'available': 1, 'inuse': 2.
 wfFrSwIsdnScrnTable 1.3.6.1.4.1.18.3.5.9.6.11 no-access
This is the incoming call screening table for the FRSW over ISDN application. The table consists of a FRSW UNI Index and a list of allowable ISDN Phone numbers for that FRSW UNI Index. The table is indexed by both the FRSW UNI Index and the ISDN Phone Number. This table is referenced only when the wfFrSwIsdnAssocScrnEnable is set to Enabled for this FRSW UNI Index.
       wfFrSwIsdnScrnEntry 1.3.6.1.4.1.18.3.5.9.6.11.1 no-access
Instance Id for this table.
           wfFrSwIsdnScrnDelete 1.3.6.1.4.1.18.3.5.9.6.11.1.1 integer read-write
Indication to delete this Scrn Instance. Enumeration: 'deleted': 2, 'created': 1.
           wfFrSwIsdnScrnIndex 1.3.6.1.4.1.18.3.5.9.6.11.1.2 integer read-only
FRSW UNI Index - A number that ties this entry to an entry in wfFrSwIsdnAssocEntry.
           wfFrSwIsdnScrnNum 1.3.6.1.4.1.18.3.5.9.6.11.1.3 octet string read-only
ISDN Phone Number of a user authorized to access the UNIs contained in the FRSW UNI Index.
 wfFrSwSigTable 1.3.6.1.4.1.18.3.5.9.6.12 no-access
The Frame relay signalling table contains frame relay signalling entries indexed by the frame relay access channel circuit number. An instance of wfFrSwSigEntry is required for each frame relay access channel with frame relay signalling enabled. The absence of wfFrSwSigEntry for a given frame relay access channel implies that frame relay signalling is disabled for the circuit. Note that the terms 'incoming' and 'outgoing' refer to the frame mode call with respect to the network side of the interface. The terminology used by CCITT Q.933/Q.931 is different.
       wfFrSwSigEntry 1.3.6.1.4.1.18.3.5.9.6.12.1 no-access
An entry in the Frame Relay signalling port information table.
           wfFrSwSigDelete 1.3.6.1.4.1.18.3.5.9.6.12.1.1 integer read-write
Indication to delete this instance Enumeration: 'deleted': 2, 'created': 1.
           wfFrSwSigCircuit 1.3.6.1.4.1.18.3.5.9.6.12.1.2 integer read-only
The circuit number for this frame relay access channel
           wfFrSwSigSvcDlciLow 1.3.6.1.4.1.18.3.5.9.6.12.1.3 integer read-write
Lowest DLCI to be used for SVC, the default value is for 2 octet frame header
           wfFrSwSigSvcDlciHigh 1.3.6.1.4.1.18.3.5.9.6.12.1.4 integer read-write
Highest DLCI to be used for SVC, the default value is for 2 octet frame header.
           wfFrSwSigDlciAssign 1.3.6.1.4.1.18.3.5.9.6.12.1.5 integer read-write
Determines if DLCI's are assigned starting at wfFrSwSigSvcDlciHigh and working towards wfFrSwSigSvcDlciLow or vice versa. Enumeration: 'decrement': 2, 'increment': 1.
           wfFrSwSigMaxNumOfSvcs 1.3.6.1.4.1.18.3.5.9.6.12.1.6 integer read-write
Indicates the maximum number of simultaneous switched virtual circuits allowed on the logical line.
           wfFrSwSigNumOfSvcsInUse 1.3.6.1.4.1.18.3.5.9.6.12.1.7 integer read-only
Indicates the number of switched virtual circuits in use on the logical line.
           wfFrSwSigDefaultThroughput 1.3.6.1.4.1.18.3.5.9.6.12.1.8 integer read-write
This value is used by the network in the Link Layer Core Parameters IE incoming & outgoing throughput fields when they are not included in the setup message by the user.
           wfFrSwSigDefaultMinAcceptThroughput 1.3.6.1.4.1.18.3.5.9.6.12.1.9 integer read-write
This value is used by the network in the Link Layer Core Parameters IE incoming & outgoing minimum acceptable throughput fields when they are not included in the setup message by the user.
           wfFrSwSigDefaultBc 1.3.6.1.4.1.18.3.5.9.6.12.1.10 integer read-only
This value is used by the network in the Link Layer Core Parameters IE incoming & outgoing Bc fields when they are not included in the setup message by the user.
           wfFrSwSigDefaultBe 1.3.6.1.4.1.18.3.5.9.6.12.1.11 integer read-write
This value is used by the network in the Link Layer Core Parameters IE incoming & outgoing Be fields when they are not included in the setup message by the user.
           wfFrSwSigMaxInThroughputPerSvc 1.3.6.1.4.1.18.3.5.9.6.12.1.12 integer read-write
This is the maximum incoming throughput that any single SVC may negotiate for a call. Calls requesting in excess of this attribute are rejected.
           wfFrSwSigMaxOutThroughputPerSvc 1.3.6.1.4.1.18.3.5.9.6.12.1.13 integer read-write
This is the maximum outgoing throughput that any single SVC may negotiate for a call. Calls requesting in excess of this attribute are rejected.
           wfFrSwSigTotalInNegotiableThroughput 1.3.6.1.4.1.18.3.5.9.6.12.1.14 integer read-write
This is the total maximum incoming throughput that is available for all frame mode calls on the port. If the sum of the incoming throughput requested by a call and wfFrSwSigTotalInCurrentThroughput is in excess of this value, the call is rejected.
           wfFrSwSigTotalInCurrentThroughput 1.3.6.1.4.1.18.3.5.9.6.12.1.15 integer read-only
This is the total incoming throughput that has been negotiated for use by all SVC's on the port.
           wfFrSwSigTotalOutNegotiableThroughput 1.3.6.1.4.1.18.3.5.9.6.12.1.16 integer read-write
This is the total maximum outgoing throughput that is available for all frame mode calls on the port. If the sum of the outgoing throughput requested by a call and wfFrSwSigTotalOutCurrentThroughput is in excess of this value, the call is rejected.
           wfFrSwSigTotalOutCurrentThroughput 1.3.6.1.4.1.18.3.5.9.6.12.1.17 integer read-only
This is the total incoming throughput that has been negotiated for use by all SVC's on the port.
           wfFrSwSigXNetClearingDisable 1.3.6.1.4.1.18.3.5.9.6.12.1.18 integer read-write
If cross-net polling (wfFrSwDlcmiCrossNetEnable) is enabled on this interface, and the error threshold (wfFrSwDlcmiCrossNetErrorThreshold) is exceeded, the network can clear the call. Enumeration: 'enable': 1, 'disable': 2.
           wfFrSwSigCallingPartyIEMandatory 1.3.6.1.4.1.18.3.5.9.6.12.1.19 integer read-write
Reject the call if the Calling Party IE is absent in the setup message or if the provided Calling Party IE fails address authentication tests againt the configured address(es) on the ingress logical line. Enumeration: 'disabled': 2, 'enabled': 1.
           wfFrSwSigT301 1.3.6.1.4.1.18.3.5.9.6.12.1.20 integer read-write
Timer number: T301 default time-out: 3 min state of call: call initiated cause for start: incoming setup normal stop: outgoing connect at the first expiry: clear call at the second expiry: timer not restarted
           wfFrSwSigT303 1.3.6.1.4.1.18.3.5.9.6.12.1.21 integer read-write
Timer number: T303 default time-out: 4 s state of call: call present cause for start: outgoing setup normal stop: incoming connect/call-proceeding/ release-complete at the first expiry: retransmit setup, restart T303 at the second expiry: clear call
           wfFrSwSigT305 1.3.6.1.4.1.18.3.5.9.6.12.1.22 integer read-write
Timer number: T305 default time-out: 30 s state of call: disconnect ind cause for start: outgoing disconnect normal stop: incoming release/disconnect at the first expiry: outgoing release at the second expiry: timer not restarted
           wfFrSwSigT308 1.3.6.1.4.1.18.3.5.9.6.12.1.23 integer read-write
Timer number: T308 default time-out: 4 s state of call: release req cause for start: outgoing release normal stop: incoming release/release-complete at the first expiry: retransmit release, restart T308 at the second expiry: place access channel in maintenance
           wfFrSwSigT310 1.3.6.1.4.1.18.3.5.9.6.12.1.24 integer read-write
Timer number: T310 default time-out: 10 s state of call: incoming call proceeding cause for start: incoming call proceeding normal stop: incoming connect/disconnect at the first expiry: clear call at the second expiry: timer not restarted
           wfFrSwSigT322 1.3.6.1.4.1.18.3.5.9.6.12.1.25 integer read-write
Timer number: T322 default time-out: 4 s state of call: any call state cause for start: outgoing status enquiry normal stop: incoming status/disconnect/ release/release-complete at the first expiry: retransmit status-enq, restart T322 at the second expiry: resend status enq and restart T322
           wfFrSwSigInSetupPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.26 counter read-only
number of incoming setup packets
           wfFrSwSigInCallProceedingPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.27 counter read-only
number of incoming call proceeding packets
           wfFrSwSigInConnectPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.28 counter read-only
number of incoming connect packets
           wfFrSwSigInDisconnectPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.29 counter read-only
number of incoming disconnect packets
           wfFrSwSigInReleasePkts 1.3.6.1.4.1.18.3.5.9.6.12.1.30 counter read-only
number of incoming release packets
           wfFrSwSigInReleaseCompletePkts 1.3.6.1.4.1.18.3.5.9.6.12.1.31 counter read-only
number of incoming release complete packets
           wfFrSwSigInStatusEnquiryPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.32 counter read-only
number of incoming status enquiry packets
           wfFrSwSigInStatusPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.33 counter read-only
number of incoming status packets
           wfFrSwSigInUnknownPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.34 counter read-only
number of incoming unknown packets
           wfFrSwSigOutSetupPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.35 counter read-only
number of outgoing setup packets
           wfFrSwSigOutCallProceedingPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.36 counter read-only
number of outgoing call proceeding packets
           wfFrSwSigOutConnectPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.37 counter read-only
number of outgoing connect packets
           wfFrSwSigOutDisconnectPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.38 counter read-only
number of outgoing disconnect packets
           wfFrSwSigOutReleasePkts 1.3.6.1.4.1.18.3.5.9.6.12.1.39 counter read-only
number of outgoing release packets
           wfFrSwSigOutReleaseCompletePkts 1.3.6.1.4.1.18.3.5.9.6.12.1.40 counter read-only
number of outgoing release packest
           wfFrSwSigOutStatusEnquiryPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.41 counter read-only
number of outgoing status enquiry packets
           wfFrSwSigOutStatusPkts 1.3.6.1.4.1.18.3.5.9.6.12.1.42 counter read-only
number of outgoing status packets
           wfFrSwSigRejectedConnRequests 1.3.6.1.4.1.18.3.5.9.6.12.1.43 counter read-only
number of connections rejected
           wfFrSwSigNwrkAbortedConnections 1.3.6.1.4.1.18.3.5.9.6.12.1.44 counter read-only
number of connections aborted by network
           wfFrSwSigL2Resets 1.3.6.1.4.1.18.3.5.9.6.12.1.45 counter read-only
number of L2 resets
           wfFrSwSigDlciIEAllowed 1.3.6.1.4.1.18.3.5.9.6.12.1.46 integer read-write
Reject the call if the Dlci IE is present in the setup message and wfFrSwSigDlciIEAllowed is set to disabled. Enumeration: 'disabled': 2, 'enabled': 1.
           wfFrSwSigX213PriorityIEAllowed 1.3.6.1.4.1.18.3.5.9.6.12.1.47 integer read-write
Reject the call if the X213 Priority IE is present in setup message and wfFrSwSigX213PriorityIEAllowed is set to disabled. Enumeration: 'disabled': 2, 'enabled': 1.
           wfFrSwSigMaximumBe 1.3.6.1.4.1.18.3.5.9.6.12.1.48 integer read-write
This value is the maximum allowed Be for a SVC connection
 wfFrSwGlobalE164AddrTable 1.3.6.1.4.1.18.3.5.9.6.13 no-access
wfFrSwGlobalE164AddrTable is used by Directory Services to translate a range of E.164 addresses into an internal IP network address. E.164 ranges must not ever overlap.
       wfFrSwGlobalE164AddrEntry 1.3.6.1.4.1.18.3.5.9.6.13.1 no-access
An entry in the Frame Relay Global E.164 Address Table.
           wfFrSwGlobalE164AddrDelete 1.3.6.1.4.1.18.3.5.9.6.13.1.1 integer read-write
Indication to delete/create this entry. Enumeration: 'deleted': 2, 'created': 1.
           wfFrSwGlobalE164AddrLow 1.3.6.1.4.1.18.3.5.9.6.13.1.2 octet string read-only
Instance identifier; the low end of the E.164 address range. This is an 8-byte fixed length octet string format, right justified with padded leading zeros as necessary.
           wfFrSwGlobalE164AddrHigh 1.3.6.1.4.1.18.3.5.9.6.13.1.3 octet string read-only
Instance identifier; the high end of the E.164 address range. This is an 8-byte fixed length octet string format, right justified with padded leading zeros as necessary.
           wfFrSwGlobalE164AddrIPAddr 1.3.6.1.4.1.18.3.5.9.6.13.1.4 ipaddress read-write
This is the internal IP network address associated with this range of E.164 addresses.
 wfFrSwGlobalX121AddrTable 1.3.6.1.4.1.18.3.5.9.6.14 no-access
wfFrSwGlobalX121AddrTable is used by Directory Services to translate a range of X.121 addresses into an internal IP network address. X.121 ranges must not ever overlap.
       wfFrSwGlobalX121AddrEntry 1.3.6.1.4.1.18.3.5.9.6.14.1 no-access
An entry in the Frame Relay Global X.121 Address Table.
           wfFrSwGlobalX121AddrDelete 1.3.6.1.4.1.18.3.5.9.6.14.1.1 integer read-write
Indication to delete/create this entry. Enumeration: 'deleted': 2, 'created': 1.
           wfFrSwGlobalX121AddrLow 1.3.6.1.4.1.18.3.5.9.6.14.1.2 octet string read-only
Instance identifier; the low end of the X.121 address range. This is an 8-byte fixed length octet string format, right justified with padded leading zeros as necessary.
           wfFrSwGlobalX121AddrHigh 1.3.6.1.4.1.18.3.5.9.6.14.1.3 octet string read-only
Instance identifier; the high end of the X.121 address range. This is an 8-byte fixed length octet string format, right justified with padded leading zeros as necessary.
           wfFrSwGlobalX121AddrIPAddr 1.3.6.1.4.1.18.3.5.9.6.14.1.4 ipaddress read-write
This is the internal IP network address associated with this range of X.121 addresses.
 wfFrSwLocalE164AddrTable 1.3.6.1.4.1.18.3.5.9.6.15 no-access
wfFrSwLocalE164AddrTable contains E.164 addresses on the local BNX and CUG (Closed User Group) related information.
       wfFrSwLocalE164AddrEntry 1.3.6.1.4.1.18.3.5.9.6.15.1 no-access
An entry in the Frame Relay Local E.164 Address Table.
           wfFrSwLocalE164AddrDelete 1.3.6.1.4.1.18.3.5.9.6.15.1.1 integer read-write
Indication to delete/create this entry. Enumeration: 'deleted': 2, 'created': 1.
           wfFrSwLocalE164AddrCct 1.3.6.1.4.1.18.3.5.9.6.15.1.2 integer read-only
Instance identifier; internal CCT number associated with this E.164 address.
           wfFrSwLocalE164Address 1.3.6.1.4.1.18.3.5.9.6.15.1.3 octet string read-only
Instance identifier; an E.164 address. This is an 8-byte fixed length octet string format, right justified with padded leading zeros as necessary.
           wfFrSwLocalE164AddrCUG 1.3.6.1.4.1.18.3.5.9.6.15.1.4 octet string read-write
CUG (Closed User Group) information. The structure of the CUG information consists zero or more groups (number of groups can be derived from the OCTET STRING data type of this MIB attribute) of COI structure information. Each COI structure consists of a COI group number (4-byte integer) and a COI list. Each COI list consists of a length field (4-byte integer) which specifies the number of bytes of COI bit-encoded information belonging to this group and the COI information structure. COI information structure is a bit mask field where each bit from left to right represents whether this E.164 address belongs to a particular COI number within this COI group number. Please note that COI group numbers can not be repeated and that the COI group numbers must be in increasing order in the CUG configuration MIB wfFrSwLocalE164AddrCUG defaults to zero COI groups which means no CUG related information and hence this local wfFrSwLocalE164Address is allowed to communicate with all users.
           wfFrSwLocalE164AddrLocalFlag 1.3.6.1.4.1.18.3.5.9.6.15.1.5 integer read-write
Local/Non-Local Identifier Flag. Used for SPVCs. Enumeration: 'local': 1, 'nonlocal': 2.
 wfFrSwLocalX121AddrTable 1.3.6.1.4.1.18.3.5.9.6.16 no-access
wfFrSwLocalX121AddrTable contains X.121 addresses on the local BNX and CUG (Closed User Group) related information.
       wfFrSwLocalX121AddrEntry 1.3.6.1.4.1.18.3.5.9.6.16.1 no-access
An entry in the Frame Relay Local X.121 Address Table.
           wfFrSwLocalX121AddrDelete 1.3.6.1.4.1.18.3.5.9.6.16.1.1 integer read-write
Indication to delete/create this entry. Enumeration: 'deleted': 2, 'created': 1.
           wfFrSwLocalX121AddrCct 1.3.6.1.4.1.18.3.5.9.6.16.1.2 integer read-only
Instance identifier; internal CCT number associated with this X.121 address.
           wfFrSwLocalX121Address 1.3.6.1.4.1.18.3.5.9.6.16.1.3 octet string read-only
Instance identifier; a X.121 address. This is an 8-byte fixed length octet string format, right justified with padded leading zeros as necessary.
           wfFrSwLocalX121AddrCUG 1.3.6.1.4.1.18.3.5.9.6.16.1.4 octet string read-write
CUG (Closed User Group) information. The structure of the CUG information consists zero or more groups (number of groups can be derived from the OCTET STRING data type of this MIB attribute) of COI structure information. Each COI structure consists of a COI group number (4-byte integer) and a COI list. Each COI list consists of a length field (4-byte integer) which specifies the number of bytes of COI bit-encoded information belonging to this group and the COI information structure. COI information structure is a bit mask field where each bit from left to right represents whether this X.121 address belongs to a particular COI number within this COI group number. wfFrSwLocalX121AddrCUG defaults to zero COI groups which means no CUG related information and hence this local wfFrSwLocalX121Address is allowed to communicate with all users.
           wfFrSwLocalX121AddrLocalFlag 1.3.6.1.4.1.18.3.5.9.6.16.1.5 integer read-write
Local/Non-Local Identifier Flag. Used for SPVCs. Enumeration: 'local': 1, 'nonlocal': 2.
 wfFrSwBase 1.3.6.1.4.1.18.3.5.9.6.17
       wfFrSwBaseDelete 1.3.6.1.4.1.18.3.5.9.6.17.1 integer read-write
Indication to delete/create this base group Enumeration: 'deleted': 2, 'created': 1.
       wfFrSwBaseIpAddr 1.3.6.1.4.1.18.3.5.9.6.17.2 ipaddress read-write
Indicates this BNX's (circuit-less) IP address
       wfFrSwBaseShutDown 1.3.6.1.4.1.18.3.5.9.6.17.3 counter read-write
Bit mask for slots to shutdown, slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
 wfFrSwCngcMonTable 1.3.6.1.4.1.18.3.5.9.6.18 no-access
This table is used by FRSW Congestion Control application. The table is used to Monitor the congestion level of a particular circuit.
       wfFrSwCngcMonEntry 1.3.6.1.4.1.18.3.5.9.6.18.1 no-access
Instance Id for this table.
           wfFrSwCngcMonReset 1.3.6.1.4.1.18.3.5.9.6.18.1.1 integer read-write
Indication to reset Cngc Monitor Counters.
           wfFrSwCngcMonCct 1.3.6.1.4.1.18.3.5.9.6.18.1.2 integer read-only
Circuit to be monitored.
           wfFrSwCngcMonP0Level1Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.3 gauge read-only
Percentage of time congestion is at level 1. for Priority 0 Traffic.
           wfFrSwCngcMonP0Level2Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.4 gauge read-only
Percentage of time congestion is at level 2. for Priority 0 Traffic.
           wfFrSwCngcMonP0Level3Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.5 gauge read-only
Percentage of time congestion is at level 3. for Priority 0 Traffic.
           wfFrSwCngcMonP0Level4Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.6 gauge read-only
Percentage of time congestion is at level 4. for Priority 0 Traffic.
           wfFrSwCngcMonP1Level1Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.7 gauge read-only
Percentage of time congestion is at level 1. for Priority 1 Traffic.
           wfFrSwCngcMonP1Level2Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.8 gauge read-only
Percentage of time congestion is at level 2. for Priority 1 Traffic.
           wfFrSwCngcMonP1Level3Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.9 gauge read-only
Percentage of time congestion is at level 3. for Priority 1 Traffic.
           wfFrSwCngcMonP1Level4Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.10 gauge read-only
Percentage of time congestion is at level 4. for Priority 1 Traffic.
           wfFrSwCngcMonP2Level1Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.11 gauge read-only
Percentage of time congestion is at level 1. for Priority 2 Traffic.
           wfFrSwCngcMonP2Level2Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.12 gauge read-only
Percentage of time congestion is at level 2. for Priority 2 Traffic.
           wfFrSwCngcMonP2Level3Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.13 gauge read-only
Percentage of time congestion is at level 3. for Priority 2 Traffic.
           wfFrSwCngcMonP2Level4Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.14 gauge read-only
Percentage of time congestion is at level 4. for Priority 2 Traffic.
           wfFrSwCngcMonP3Level1Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.15 gauge read-only
Percentage of time congestion is at level 1. for Priority 3 Traffic.
           wfFrSwCngcMonP3Level2Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.16 gauge read-only
Percentage of time congestion is at level 2. for Priority 3 Traffic.
           wfFrSwCngcMonP3Level3Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.17 gauge read-only
Percentage of time congestion is at level 3. for Priority 3 Traffic.
           wfFrSwCngcMonP3Level4Percent 1.3.6.1.4.1.18.3.5.9.6.18.1.18 gauge read-only
Percentage of time congestion is at level 4. for Priority 3 Traffic.
 wfFrSwVirtualIntfTable 1.3.6.1.4.1.18.3.5.9.6.19 no-access
The table is used to create 'virtual' FRSW access lines.
       wfFrSwVirtualIntfEntry 1.3.6.1.4.1.18.3.5.9.6.19.1 no-access
Instance Id for this table.
           wfFrSwVirtualIntfDelete 1.3.6.1.4.1.18.3.5.9.6.19.1.1 integer read-write
Indication to delete this virtual interface. Enumeration: 'deleted': 2, 'created': 1.
           wfFrSwVirtualIntfSlot 1.3.6.1.4.1.18.3.5.9.6.19.1.2 integer read-only
Instance identifier; the slot number of this interface.
           wfFrSwVirtualIntfCct 1.3.6.1.4.1.18.3.5.9.6.19.1.3 integer read-only
Instance identifier; the circuit number of this interface.
           wfFrSwVirtualIntfLineNum 1.3.6.1.4.1.18.3.5.9.6.19.1.4 integer read-only
Line number for this virtual interface.
 wfFrSwExtFileSysTable 1.3.6.1.4.1.18.3.5.9.6.20 no-access
This table is used by FRSW to extend the file system to DRAM device.
       wfFrSwExtFileSysEntry 1.3.6.1.4.1.18.3.5.9.6.20.1 no-access
Instance Id for this table.
           wfFrSwExtFileSysDelete 1.3.6.1.4.1.18.3.5.9.6.20.1.1 integer read-write
Indication to delete/create this entry. Enumeration: 'deleted': 2, 'created': 1.
           wfFrSwExtFileSysSlot 1.3.6.1.4.1.18.3.5.9.6.20.1.2 integer read-only
A unique value for each slot. Its value ranges between 1 and 14.
           wfFrSwExtFileSysSize 1.3.6.1.4.1.18.3.5.9.6.20.1.3 integer read-write
The memory size of the extended file system in byte unit. The value zero also means that extended file system is disabled. Non-zero value means enabled. Its suggested that the size is in multiple of 128k bytes. Some of the well-known memory sizes and their correspond decimal values are as followed: Mem size Decimal Value ^^^^^^^^ ^^^^^^^^^^^^^ 128K 131072 256K 262144 512K 524288 1M 1048576 2M 2097152 4M 4194304 8M 8388608
           wfFrSwExtFileSysActualSize 1.3.6.1.4.1.18.3.5.9.6.20.1.4 integer read-only
The actual memory size the system allocated.
           wfFrSwExtFileSysState 1.3.6.1.4.1.18.3.5.9.6.20.1.5 integer read-only
The status of the extended file system. State up indicates that the requested memory size for the extended file system has been allocated successfully and the extended file system is in operational state. State fault indicates that the requested memory size for the extended file system has NOT been allocated successfully and the extended file system is NOT in operational state. One reason for entering the fault state is insufficient available memory. State init indicates that the system is in the initialization cycle. The extended file system is not operational. State notpresent reflects the size of zero. Enumeration: 'notpresent': 4, 'fault': 2, 'init': 3, 'up': 1.