Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wfDs3Config 1.3.6.1.4.1.18.3.4.13.1 no-access
The DS3 Configuration table
     wfDs3ConfigEntry 1.3.6.1.4.1.18.3.4.13.1.1 no-access
per circuit DS3 configuration objects; wfDs3LineIndex corresponds to Wellfleet circuit number
         wfDs3LineIndex 1.3.6.1.4.1.18.3.4.13.1.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs3TimeElapsed 1.3.6.1.4.1.18.3.4.13.1.1.2 integer read-only
1..900 seconds within the current 15-minute interval
         wfDs3ValidIntervals 1.3.6.1.4.1.18.3.4.13.1.1.3 integer read-only
0..96 previous intervals that valid data were collected. This is 96 unless the CSU device was brought on line within the last 24 hours.
         wfDs3LineType 1.3.6.1.4.1.18.3.4.13.1.1.4 integer read-only
the variety of DS3 implementing this circuit Enumeration: 'ds3cbitparity': 4, 'ds3clearchannel': 5, 'other': 1.
         wfDs3ZeroCoding 1.3.6.1.4.1.18.3.4.13.1.1.5 integer read-only
the variety of Zero Code Suppression used on the link Enumeration: 'ds3b3zs': 2.
         wfDs3SendCode 1.3.6.1.4.1.18.3.4.13.1.1.6 integer read-only
the type of code being sent across the DS3 circuit by the CSU Enumeration: 'ds3sendnocode': 2.
         wfDs3CircuitIdentifier 1.3.6.1.4.1.18.3.4.13.1.1.7 displaystring read-only
the transmission vendor's circuit identifier
         wfDs3LoopbackConfig 1.3.6.1.4.1.18.3.4.13.1.1.8 integer read-only
the loopback state of the CSU Enumeration: 'ds3mgrlineloop': 3, 'ds3netreqlineloop': 5, 'ds3netreqpayloadloop': 4, 'ds3otherloop': 6, 'ds3noloop': 1, 'ds3mgrpayloadloop': 2.
         wfDs3LineStatus 1.3.6.1.4.1.18.3.4.13.1.1.9 integer read-only
the state of the DS3 line Enumeration: 'ds3noalarm': 1, 'ds3lossofsignal': 16, 'ds3lossofframe': 8, 'ds3alarmindicationsignal': 4, 'ds3loopbackstate': 32, 'ds3farendalarm': 2.
 wfDs3Current 1.3.6.1.4.1.18.3.4.13.2 no-access
The DS3 Current table
     wfDs3CurrentEntry 1.3.6.1.4.1.18.3.4.13.2.1 no-access
per circuit DS3 current objects - wfDs3CurrentIndex corresponds to Wellfleet circuit number
         wfDs3CurrentIndex 1.3.6.1.4.1.18.3.4.13.2.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs3CurrentESs 1.3.6.1.4.1.18.3.4.13.2.1.2 counter read-only
the count of errored seconds in the current interval
         wfDs3CurrentSESs 1.3.6.1.4.1.18.3.4.13.2.1.3 counter read-only
the count of severely errored seconds in the current interval
         wfDs3CurrentSEFs 1.3.6.1.4.1.18.3.4.13.2.1.4 counter read-only
the count of severely errored framing seconds in the current interval
         wfDs3CurrentUASs 1.3.6.1.4.1.18.3.4.13.2.1.5 counter read-only
the number of unavailable seconds in the current interval
         wfDs3CurrentBPVs 1.3.6.1.4.1.18.3.4.13.2.1.6 counter read-only
the count of bipolar violations in the current interval
         wfDs3CurrentCVs 1.3.6.1.4.1.18.3.4.13.2.1.7 counter read-only
the count of code violation error events in the current interval
 wfDs3Interval 1.3.6.1.4.1.18.3.4.13.3 no-access
The DS3 Interval table
     wfDs3IntervalEntry 1.3.6.1.4.1.18.3.4.13.3.1 no-access
per circuit DS3 interval objects - wfDs3IntervalIndex corresponds to Wellfleet circuit number, wfDs3IntervalNumber is the numbered previous 15-minute interval
         wfDs3IntervalIndex 1.3.6.1.4.1.18.3.4.13.3.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs3IntervalNumber 1.3.6.1.4.1.18.3.4.13.3.1.2 integer read-only
1..96 where 1 is the most recent 15-minute interval and 96 is the least
         wfDs3IntervalESs 1.3.6.1.4.1.18.3.4.13.3.1.3 gauge read-only
the count of errored seconds in the specified interval
         wfDs3IntervalSESs 1.3.6.1.4.1.18.3.4.13.3.1.4 gauge read-only
the count of severely errored seconds in the specified interval
         wfDs3IntervalSEFs 1.3.6.1.4.1.18.3.4.13.3.1.5 gauge read-only
the count of severely errored framing seconds in the specified interval
         wfDs3IntervalUASs 1.3.6.1.4.1.18.3.4.13.3.1.6 gauge read-only
the number of unavailable seconds in the specified interval
         wfDs3IntervalBPVs 1.3.6.1.4.1.18.3.4.13.3.1.7 gauge read-only
the count of bipolar violations in the specified interval
         wfDs3IntervalCVs 1.3.6.1.4.1.18.3.4.13.3.1.8 gauge read-only
the count of code violation error events in the specified interval
 wfDs3Total 1.3.6.1.4.1.18.3.4.13.4 no-access
The DS3 Total table
     wfDs3TotalEntry 1.3.6.1.4.1.18.3.4.13.4.1 no-access
per circuit DS3 total objects - wfDs3TotalIndex corresponds to Wellfleet circuit number
         wfDs3TotalIndex 1.3.6.1.4.1.18.3.4.13.4.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs3TotalESs 1.3.6.1.4.1.18.3.4.13.4.1.2 gauge read-only
total count of errored seconds
         wfDs3TotalSESs 1.3.6.1.4.1.18.3.4.13.4.1.3 gauge read-only
total count of severely errored seconds
         wfDs3TotalSEFs 1.3.6.1.4.1.18.3.4.13.4.1.4 gauge read-only
total count of severely errored framing seconds
         wfDs3TotalUASs 1.3.6.1.4.1.18.3.4.13.4.1.5 gauge read-only
total number of unavailable seconds
         wfDs3TotalBPVs 1.3.6.1.4.1.18.3.4.13.4.1.6 gauge read-only
total count of bipolar violations
         wfDs3TotalCVs 1.3.6.1.4.1.18.3.4.13.4.1.7 gauge read-only
total count of code violation error events
 wfDs3FeConfig 1.3.6.1.4.1.18.3.4.13.5 no-access
The DS3 Far End Configuration table
     wfDs3FeConfigEntry 1.3.6.1.4.1.18.3.4.13.5.1 no-access
per circuit DS3 far end config objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number
         wfDs3FeConfigIndex 1.3.6.1.4.1.18.3.4.13.5.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs3FarEndEquipCode 1.3.6.1.4.1.18.3.4.13.5.1.2 displaystring read-write
equipment description code - C-bit parity only
         wfDs3FarEndLocationIDCode 1.3.6.1.4.1.18.3.4.13.5.1.3 displaystring read-write
equipment location code - C-bit parity only
         wfDs3FarEndFrameIDCode 1.3.6.1.4.1.18.3.4.13.5.1.4 displaystring read-write
code for the equipment location within a building
         wfDs3FarEndUnitCode 1.3.6.1.4.1.18.3.4.13.5.1.5 displaystring read-write
code for the equipment location within a bay
         wfDs3FarEndFacilityIDCode 1.3.6.1.4.1.18.3.4.13.5.1.6 displaystring read-write
path identification code
 wfDs3FeCurrent 1.3.6.1.4.1.18.3.4.13.6 no-access
The DS3 Far End Current table
     wfDs3FeCurrentEntry 1.3.6.1.4.1.18.3.4.13.6.1 no-access
per circuit DS3 far end current objects wfDs3FeCurrentIndex corresponds to Wellfleet circuit number
         wfDs3FeCurrentIndex 1.3.6.1.4.1.18.3.4.13.6.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs3FeCurrentESs 1.3.6.1.4.1.18.3.4.13.6.1.2 counter read-only
the count of errored seconds in the current interval
         wfDs3FeCurrentSESs 1.3.6.1.4.1.18.3.4.13.6.1.3 counter read-only
the count of severely errored seconds in the current interval
         wfDs3FeCurrentCVs 1.3.6.1.4.1.18.3.4.13.6.1.4 counter read-only
the count of code violation error events in the current interval
 wfDs3FeInterval 1.3.6.1.4.1.18.3.4.13.7 no-access
The DS3 Far End Interval table
     wfDs3FeIntervalEntry 1.3.6.1.4.1.18.3.4.13.7.1 no-access
per circuit DS3 far end interval objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number, wfDs3FeIntervalNumber is the numbered previous 15-minute interval
         wfDs3FeIntervalIndex 1.3.6.1.4.1.18.3.4.13.7.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs3FeIntervalNumber 1.3.6.1.4.1.18.3.4.13.7.1.2 integer read-only
1..96 where 1 is the most recent 15-minute interval and 96 is the least
         wfDs3FeIntervalESs 1.3.6.1.4.1.18.3.4.13.7.1.3 gauge read-only
the count of errored seconds in the specified interval
         wfDs3FeIntervalSESs 1.3.6.1.4.1.18.3.4.13.7.1.4 gauge read-only
the count of severely errored seconds in the specified interval
         wfDs3FeIntervalCVs 1.3.6.1.4.1.18.3.4.13.7.1.5 gauge read-only
the count of code violation error events in the specified interval
 wfDs3FeTotal 1.3.6.1.4.1.18.3.4.13.8 no-access
The DS3 Far End Total table
     wfDs3FeTotalEntry 1.3.6.1.4.1.18.3.4.13.8.1 no-access
per circuit far end DS3 total objects - wfDs3FeTotalIndex corresponds to Wellfleet circuit number
         wfDs3FeTotalIndex 1.3.6.1.4.1.18.3.4.13.8.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs3FeTotalESs 1.3.6.1.4.1.18.3.4.13.8.1.2 gauge read-only
total count of errored seconds
         wfDs3FeTotalSESs 1.3.6.1.4.1.18.3.4.13.8.1.3 gauge read-only
total count of severely errored seconds
         wfDs3FeTotalCVs 1.3.6.1.4.1.18.3.4.13.8.1.4 gauge read-only
total count of code violation error events