Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wfDs1Config 1.3.6.1.4.1.18.3.4.12.1 no-access
The DS1 Configuration table
     wfDs1ConfigEntry 1.3.6.1.4.1.18.3.4.12.1.1 no-access
per circuit DS1 configuration objects; wfDs1LineIndex corresponds to Wellfleet circuit number
         wfDs1LineIndex 1.3.6.1.4.1.18.3.4.12.1.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs1TimeElapsed 1.3.6.1.4.1.18.3.4.12.1.1.2 integer read-only
1..900 seconds within the current 15-minute interval
         wfDs1ValidIntervals 1.3.6.1.4.1.18.3.4.12.1.1.3 integer read-only
0..96 previous intervals that valid data were collected. This is 96 unless the CSU device was brought on line within the last 24 hours.
         wfDs1LineType 1.3.6.1.4.1.18.3.4.12.1.1.4 integer read-only
the variety of DS1 implementing this circuit Enumeration: 'ds1ansi-esf': 4.
         wfDs1ZeroCoding 1.3.6.1.4.1.18.3.4.12.1.1.5 integer read-only
the variety of Zero Code Suppression used on the link Enumeration: 'ds1b8zs': 2, 'ds1zbtsi': 5.
         wfDs1SendCode 1.3.6.1.4.1.18.3.4.12.1.1.6 integer read-only
the type of code being sent across the DS1 circuit by the CSU Enumeration: 'ds1sendnocode': 2.
         wfDs1CircuitIdentifier 1.3.6.1.4.1.18.3.4.12.1.1.7 displaystring read-only
the transmission vendor's circuit identifier
         wfDs1LoopbackConfig 1.3.6.1.4.1.18.3.4.12.1.1.8 integer read-only
the loopback state of the CSU Enumeration: 'ds1mgrpayloadloop': 2, 'ds1noloop': 1, 'ds1mgrlineloop': 3, 'ds1otherloop': 6, 'ds1netreqpayloadloop': 4, 'ds1netreqlineloop': 5.
         wfDs1LineStatus 1.3.6.1.4.1.18.3.4.12.1.1.9 integer read-only
the state of the DS1 line Enumeration: 'ds1lossofframe': 8, 'ds1loopbackstate': 32, 'ds1farendalarm': 2, 'ds1alarmindicationsignal': 4, 'ds1noalarm': 1, 'ds1lossofsignal': 16.
 wfDs1Current 1.3.6.1.4.1.18.3.4.12.2 no-access
The DS1 Current table
     wfDs1CurrentEntry 1.3.6.1.4.1.18.3.4.12.2.1 no-access
per circuit DS1 current objects - wfDs1CurrentIndex corresponds to Wellfleet circuit number
         wfDs1CurrentIndex 1.3.6.1.4.1.18.3.4.12.2.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs1CurrentESs 1.3.6.1.4.1.18.3.4.12.2.1.2 counter read-only
the count of errored seconds in the current interval
         wfDs1CurrentSESs 1.3.6.1.4.1.18.3.4.12.2.1.3 counter read-only
the count of severely errored seconds in the current interval
         wfDs1CurrentSEFs 1.3.6.1.4.1.18.3.4.12.2.1.4 counter read-only
the count of severely errored framing seconds in the current interval
         wfDs1CurrentUASs 1.3.6.1.4.1.18.3.4.12.2.1.5 counter read-only
the number of unavailable seconds in the current interval
         wfDs1CurrentBPVs 1.3.6.1.4.1.18.3.4.12.2.1.6 counter read-only
the count of bipolar violations in the current interval
         wfDs1CurrentCVs 1.3.6.1.4.1.18.3.4.12.2.1.7 counter read-only
the count of code violation error events in the current interval
 wfDs1Interval 1.3.6.1.4.1.18.3.4.12.3 no-access
The DS1 Interval table
     wfDs1IntervalEntry 1.3.6.1.4.1.18.3.4.12.3.1 no-access
per circuit DS1 interval objects - wfDs1IntervalIndex corresponds to Wellfleet circuit number, wfDs1IntervalNumber is the numbered previous 15-minute interval
         wfDs1IntervalIndex 1.3.6.1.4.1.18.3.4.12.3.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs1IntervalNumber 1.3.6.1.4.1.18.3.4.12.3.1.2 integer read-only
1..96 where 1 is the most recent 15-minute interval and 96 is the least
         wfDs1IntervalESs 1.3.6.1.4.1.18.3.4.12.3.1.3 gauge read-only
the count of errored seconds in the specified interval
         wfDs1IntervalSESs 1.3.6.1.4.1.18.3.4.12.3.1.4 gauge read-only
the count of severely errored seconds in the specified interval
         wfDs1IntervalSEFs 1.3.6.1.4.1.18.3.4.12.3.1.5 gauge read-only
the count of severely errored framing seconds in the specified interval
         wfDs1IntervalUASs 1.3.6.1.4.1.18.3.4.12.3.1.6 gauge read-only
the number of unavailable seconds in the specified interval
         wfDs1IntervalBPVs 1.3.6.1.4.1.18.3.4.12.3.1.7 gauge read-only
the count of bipolar violations in the specified interval
         wfDs1IntervalCVs 1.3.6.1.4.1.18.3.4.12.3.1.8 gauge read-only
the count of code violation error events in the specified interval
 wfDs1Total 1.3.6.1.4.1.18.3.4.12.4 no-access
The DS1 Total table
     wfDs1TotalEntry 1.3.6.1.4.1.18.3.4.12.4.1 no-access
per circuit DS1 total objects - wfDs1TotalIndex corresponds to Wellfleet circuit number
         wfDs1TotalIndex 1.3.6.1.4.1.18.3.4.12.4.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs1TotalESs 1.3.6.1.4.1.18.3.4.12.4.1.2 gauge read-only
total count of errored seconds
         wfDs1TotalSESs 1.3.6.1.4.1.18.3.4.12.4.1.3 gauge read-only
total count of severely errored seconds
         wfDs1TotalSEFs 1.3.6.1.4.1.18.3.4.12.4.1.4 gauge read-only
total count of severely errored framing seconds
         wfDs1TotalUASs 1.3.6.1.4.1.18.3.4.12.4.1.5 gauge read-only
total number of unavailable seconds
         wfDs1TotalBPVs 1.3.6.1.4.1.18.3.4.12.4.1.6 gauge read-only
total count of bipolar violations
         wfDs1TotalCVs 1.3.6.1.4.1.18.3.4.12.4.1.7 gauge read-only
total count of code violation error events
 wfDs1FeCurrent 1.3.6.1.4.1.18.3.4.12.5 no-access
The DS1 Far End Current table
     wfDs1FeCurrentEntry 1.3.6.1.4.1.18.3.4.12.5.1 no-access
per circuit DS1 far end current objects wfDs1CurrentIndex corresponds to Wellfleet circuit number
         wfDs1FeCurrentIndex 1.3.6.1.4.1.18.3.4.12.5.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs1FeCurrentESs 1.3.6.1.4.1.18.3.4.12.5.1.2 counter read-only
the count of errored seconds in the current interval
         wfDs1FeCurrentSESs 1.3.6.1.4.1.18.3.4.12.5.1.3 counter read-only
the count of severely errored seconds in the current interval
         wfDs1FeCurrentSEFs 1.3.6.1.4.1.18.3.4.12.5.1.4 counter read-only
the count of severely errored framing seconds in the current interval
         wfDs1FeCurrentBPVs 1.3.6.1.4.1.18.3.4.12.5.1.5 counter read-only
the count of bipolar violations in the current interval
         wfDs1FeCurrentCVs 1.3.6.1.4.1.18.3.4.12.5.1.6 counter read-only
the count of code violation error events in the current interval
 wfDs1FeInterval 1.3.6.1.4.1.18.3.4.12.6 no-access
The DS1 Far End Interval table
     wfDs1FeIntervalEntry 1.3.6.1.4.1.18.3.4.12.6.1 no-access
per circuit DS1 far end interval objects - wfDs1FeIntervalIndex corresponds to Wellfleet circuit number, wfDs1FeIntervalNumber is the numbered previous 15-minute interval
         wfDs1FeIntervalIndex 1.3.6.1.4.1.18.3.4.12.6.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs1FeIntervalNumber 1.3.6.1.4.1.18.3.4.12.6.1.2 integer read-only
1..96 where 1 is the most recent 15-minute interval and 96 is the least
         wfDs1FeIntervalESs 1.3.6.1.4.1.18.3.4.12.6.1.3 gauge read-only
the count of errored seconds in the specified interval
         wfDs1FeIntervalSESs 1.3.6.1.4.1.18.3.4.12.6.1.4 gauge read-only
the count of severely errored seconds in the specified interval
         wfDs1FeIntervalSEFs 1.3.6.1.4.1.18.3.4.12.6.1.5 gauge read-only
the count of severely errored framing seconds in the specified interval
         wfDs1FeIntervalBPVs 1.3.6.1.4.1.18.3.4.12.6.1.6 gauge read-only
the count of bipolar violations in the specified interval
         wfDs1FeIntervalCVs 1.3.6.1.4.1.18.3.4.12.6.1.7 gauge read-only
the count of code violation error events in the specified interval
 wfDs1FeTotal 1.3.6.1.4.1.18.3.4.12.7 no-access
The DS1 Far End Total table
     wfDs1FeTotalEntry 1.3.6.1.4.1.18.3.4.12.7.1 no-access
per circuit DS1 far end total objects - wfDs1FeTotalIndex corresponds to Wellfleet circuit number
         wfDs1FeTotalIndex 1.3.6.1.4.1.18.3.4.12.7.1.1 integer read-only
this corresponds to the Wellfleet circuit number
         wfDs1FeTotalESs 1.3.6.1.4.1.18.3.4.12.7.1.2 gauge read-only
total count of errored seconds
         wfDs1FeTotalSESs 1.3.6.1.4.1.18.3.4.12.7.1.3 gauge read-only
total count of severely errored seconds
         wfDs1FeTotalSEFs 1.3.6.1.4.1.18.3.4.12.7.1.4 gauge read-only
total count of severely errored framing seconds
         wfDs1FeTotalBPVs 1.3.6.1.4.1.18.3.4.12.7.1.5 gauge read-only
total count of bipolar violations
         wfDs1FeTotalCVs 1.3.6.1.4.1.18.3.4.12.7.1.6 gauge read-only
total count of code violation error events