Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wfConsole 1.3.6.1.4.1.18.3.3.2.1
     wfBaudRate 1.3.6.1.4.1.18.3.3.2.1.1 integer read-write
Baud rate configured on the Technician Interface console
     wfDataBits 1.3.6.1.4.1.18.3.3.2.1.2 integer read-write
Number of data bits configured on the Technician Interface console
     wfParity 1.3.6.1.4.1.18.3.3.2.1.3 integer read-write
Type of parity configured on the Technician Interface console Enumeration: 'even': 3, 'none': 1, 'odd': 2.
     wfStopBits 1.3.6.1.4.1.18.3.3.2.1.4 integer read-write
Number of stop bits configured on the Technician Interface console Enumeration: 's15bit': 2, 's2bit': 3, 's1bit': 1.
     wfModemEnable 1.3.6.1.4.1.18.3.3.2.1.5 integer read-write
Enable the Technician Interface console to run over a modem Enumeration: 'disabled': 2, 'enabled': 1.
     wfLinesPerScreen 1.3.6.1.4.1.18.3.3.2.1.6 integer read-write
Number of lines which can be displayed in one screen on the Technician Interface console
     wfMoreEnable 1.3.6.1.4.1.18.3.3.2.1.7 integer read-write
Enable the 'more' feature on the Technician Interface console Enumeration: 'disabled': 2, 'enabled': 1.
     wfPrompt 1.3.6.1.4.1.18.3.3.2.1.8 displaystring read-write
Character string which will be used as the system prompt on the Technician Interface console
     wfLoginTimeOut 1.3.6.1.4.1.18.3.3.2.1.9 integer read-write
IF MODEM_ENABLED then time out in minutes to HUP when at the login prompt
     wfPasswordTimeOut 1.3.6.1.4.1.18.3.3.2.1.10 integer read-write
Timout on Password entry
     wfCommandTimeOut 1.3.6.1.4.1.18.3.3.2.1.11 integer read-write
IF MODEM_ENABLED then time out in minutes to HUP when at the command prompt
     wfLoginRetries 1.3.6.1.4.1.18.3.3.2.1.12 integer read-write
IF MODEM_ENABLED then limit # of login attempts then HUP
     wfTotalLogins 1.3.6.1.4.1.18.3.3.2.1.13 counter read-only
Total number of TI login attempts
     wfUserLoginErrors 1.3.6.1.4.1.18.3.3.2.1.14 counter read-only
Total number of FAILED User login attempts
     wfManagerLoginErrors 1.3.6.1.4.1.18.3.3.2.1.15 counter read-only
Total number of FAILED Manager login attempts
     wfOtherLoginErrors 1.3.6.1.4.1.18.3.3.2.1.16 counter read-only
Total number of FAILED Other login attempts
     wfTtyFrameErrors 1.3.6.1.4.1.18.3.3.2.1.17 counter read-only
Count of TTY Frame errors
     wfTtyOverrunErrors 1.3.6.1.4.1.18.3.3.2.1.18 counter read-only
Count of TTY Overrun errors
     wfTtyParityErrors 1.3.6.1.4.1.18.3.3.2.1.19 counter read-only
Count of TTY Parity errors
     wfTtyInfifoErrors 1.3.6.1.4.1.18.3.3.2.1.20 counter read-only
Count of TTY Input Fifo errors
       wfSerialPortTable 1.3.6.1.4.1.18.3.3.2.11.1 no-access
Configuration of system serial port(s)
           wfSerialPortEntry 1.3.6.1.4.1.18.3.3.2.11.1.1 no-access
Information for each serial port.
               wfSerialPortDelete 1.3.6.1.4.1.18.3.3.2.11.1.1.1 integer read-write
Flag to indicate Serial Port instance deletion Enumeration: 'deleted': 2, 'created': 1.
               wfSerialPortDisable 1.3.6.1.4.1.18.3.3.2.11.1.1.2 integer read-write
Enable or disable this Serial Port Enumeration: 'disabled': 2, 'enabled': 1.
               wfSerialPortState 1.3.6.1.4.1.18.3.3.2.11.1.1.3 integer read-only
The state of this Serial Port Enumeration: 'down': 2, 'init': 3, 'up': 1, 'notpresent': 4.
               wfSerialPortNumber 1.3.6.1.4.1.18.3.3.2.11.1.1.4 integer read-only
Serial Port number
               wfSerialPortName 1.3.6.1.4.1.18.3.3.2.11.1.1.5 displaystring read-only
Serial Port name
               wfSerialPortSlot 1.3.6.1.4.1.18.3.3.2.11.1.1.6 integer read-only
Slot number of Serial Port session
               wfSerialPortType 1.3.6.1.4.1.18.3.3.2.11.1.1.7 integer read-write
Type of Serial Port Enumeration: 'rtelnet': 3, 'printer': 2, 'ti': 1.
               wfSerialPortBaudRate 1.3.6.1.4.1.18.3.3.2.11.1.1.8 integer read-write
Baud rate configured on this Serial Port
               wfSerialPortDataBits 1.3.6.1.4.1.18.3.3.2.11.1.1.9 integer read-write
Number of data bits configured on this Serial Port
               wfSerialPortParity 1.3.6.1.4.1.18.3.3.2.11.1.1.10 integer read-write
Type of parity configured on this Serial Port Enumeration: 'even': 3, 'none': 1, 'odd': 2.
               wfSerialPortStopBits 1.3.6.1.4.1.18.3.3.2.11.1.1.11 integer read-write
Number of stop bits configured on this Serial Port Enumeration: 's15bit': 2, 's2bit': 3, 's1bit': 1.
               wfSerialPortModemEnable 1.3.6.1.4.1.18.3.3.2.11.1.1.12 integer read-write
Enable the Serial Port to run with modem leads enabled Enumeration: 'disabled': 2, 'enabled': 1.
               wfSerialPortLinesPerScreen 1.3.6.1.4.1.18.3.3.2.11.1.1.13 integer read-write
Number of lines which can be displayed in one screen on the Serial Port
               wfSerialPortMoreEnable 1.3.6.1.4.1.18.3.3.2.11.1.1.14 integer read-write
Enable the 'more' feature on the Serial Port Enumeration: 'disabled': 2, 'enabled': 1.
               wfSerialPortPrompt 1.3.6.1.4.1.18.3.3.2.11.1.1.15 displaystring read-write
Character string which will be used as the system prompt on the Serial Port
               wfSerialPortLoginTimeOut 1.3.6.1.4.1.18.3.3.2.11.1.1.16 integer read-write
IF MODEM_ENABLED then time out in minutes to HUP when at the login prompt
               wfSerialPortPasswordTimeOut 1.3.6.1.4.1.18.3.3.2.11.1.1.17 integer read-write
Timout on Password entry
               wfSerialPortCommandTimeOut 1.3.6.1.4.1.18.3.3.2.11.1.1.18 integer read-write
IF MODEM_ENABLED then time out in minutes to HUP when at the command prompt
               wfSerialPortLoginRetries 1.3.6.1.4.1.18.3.3.2.11.1.1.19 integer read-write
IF MODEM_ENABLED then limit # of login attempts then HUP
               wfSerialPortTotalLogins 1.3.6.1.4.1.18.3.3.2.11.1.1.20 counter read-only
Total number of TI login attempts on Serial Port
               wfSerialPortUserLoginErrors 1.3.6.1.4.1.18.3.3.2.11.1.1.21 counter read-only
Total number of FAILED User login attempts on Serial Port
               wfSerialPortManagerLoginErrors 1.3.6.1.4.1.18.3.3.2.11.1.1.22 counter read-only
Total number of FAILED Manager login attempts on Serial Port
               wfSerialPortOtherLoginErrors 1.3.6.1.4.1.18.3.3.2.11.1.1.23 counter read-only
Total number of FAILED Other login attempts on Serial Port
               wfSerialPortTtyFrameErrors 1.3.6.1.4.1.18.3.3.2.11.1.1.24 counter read-only
Count of TTY Frame errors on Serial Port
               wfSerialPortTtyOverrunErrors 1.3.6.1.4.1.18.3.3.2.11.1.1.25 counter read-only
Count of TTY Overrun errors on Serial Port
               wfSerialPortTtyParityErrors 1.3.6.1.4.1.18.3.3.2.11.1.1.26 counter read-only
Count of TTY Parity errors on Serial Port
               wfSerialPortTtyInfifoErrors 1.3.6.1.4.1.18.3.3.2.11.1.1.27 counter read-only
Count of TTY Input Fifo errors on Serial Port
               wfSerialPortInitialSearchPath 1.3.6.1.4.1.18.3.3.2.11.1.1.28 displaystring read-write
Example: 'A:;1:;2:' or '2:;4:6:;9:
               wfSerialPortManagerAutoScript 1.3.6.1.4.1.18.3.3.2.11.1.1.29 displaystring read-write
for each login.
               wfSerialPortUserAutoScript 1.3.6.1.4.1.18.3.3.2.11.1.1.30 displaystring read-write
for each login.
               wfSerialPortUserAbortLogoutDisable 1.3.6.1.4.1.18.3.3.2.11.1.1.31 integer read-write
a USER from escaping out of the User Autoscript Enumeration: 'disabled': 2, 'enabled': 1.
               wfSerialPortHistoryDepth 1.3.6.1.4.1.18.3.3.2.11.1.1.32 integer read-write
TI command history table size
               wfSerialPortAutoSaveNumFiles 1.3.6.1.4.1.18.3.3.2.11.1.1.33 integer read-write
Number of times AutoSave will save the log 0 - disable the AutoSave log
               wfSerialPortAutoSaveVolume 1.3.6.1.4.1.18.3.3.2.11.1.1.34 displaystring read-write
Volume, to which AutoSave will save logs Example: 'A:' or '2:'
               wfSerialPortModemIdSwRev 1.3.6.1.4.1.18.3.3.2.11.1.1.35 displaystring read-only
A textual description of the modem's firmware version number.
               wfSerialPortModemIdHwRev 1.3.6.1.4.1.18.3.3.2.11.1.1.36 displaystring read-only
A textual description of the revision number of the modem daughter card.
               wfSerialPortModemLineState 1.3.6.1.4.1.18.3.3.2.11.1.1.37 integer read-only
Indicates the state of the modem. Enumeration: 'reset': 6, 'unknown': 1, 'onHook': 2, 'connected': 4, 'busiedOut': 5, 'offHook': 3.
               wfSerialPortModemCfgFactoryDefaults 1.3.6.1.4.1.18.3.3.2.11.1.1.38 integer read-write
This object indicates if factory defaults are to be loaded. If set to enabled(1), factory defaults are loaded. If set to disabled(2), the initialization string in wfModemCfgInitString is not sent to the modem. Enumeration: 'disabled': 2, 'enabled': 1.
               wfSerialPortModemCfgInitString 1.3.6.1.4.1.18.3.3.2.11.1.1.39 displaystring read-write
An initialization string that will be sent to the modem each time the modem is rebooted.
               wfSerialPortModemCfgDefaultString 1.3.6.1.4.1.18.3.3.2.11.1.1.40 displaystring read-only
The string contains AT comands for initializing the modem every time the modem comes up, regardless of configuration.
               wfSerialPortModemCfgResultCodeString 1.3.6.1.4.1.18.3.3.2.11.1.1.41 displaystring read-only
The ASCII response string returned by the modem. Response strings will be returned in response to last command to the modem and in response to activity on the line.
               wfSerialPortModemCfgState 1.3.6.1.4.1.18.3.3.2.11.1.1.42 integer read-write
Indicates the state of AT command processing. When a new initialization string is to be sent to the modem, the sender sets the state to cfgInProgress(2). After the command has been sent to the modem, and a result code has been returned, the state is set to cfgResponseReturned(3). Once the sender has received the return code, the sender sets the state to cfgIdle(1). Enumeration: 'cfgInProgress': 2, 'cfgResponseReturned': 3, 'cfgIdle': 1.
               wfSerialPortModemCfgCountry 1.3.6.1.4.1.18.3.3.2.11.1.1.43 integer read-write
Identifies the country the modem is designed to operate in. This object is not read from the modem directly. It must be entered manually when configuring the modem. Enumeration: 'japan': 2, 'northAmerica': 1, 'germany': 4, 'uk': 3.
               wfSerialPortModemInitState 1.3.6.1.4.1.18.3.3.2.11.1.1.44 integer read-only
Indictes the state of the modem initialization sequence. The state will freeze in the state that fails when a failure is detected. Otherwise, the state will be set to initComplete when initialization completes successfully. The state number correspond to those for the COM port modems. Some of the states are not valid for the console modem. Enumeration: 'initialization': 5, 'initComplete': 8, 'startup': 1, 'setDefaults': 4, 'getInfo': 3.