WebGraph-Thermo-Hygrometer-US-MIB: View SNMP OID List / Download MIB
VENDOR: WIESEMANN N THEIS
Home | MIB: WebGraph-Thermo-Hygrometer-US-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
wut | 1.3.6.1.4.1.5040 | |||
wtComServer | 1.3.6.1.4.1.5040.1 | |||
wtWebio | 1.3.6.1.4.1.5040.1.2 | |||
wtWebGraphThermHygro | 1.3.6.1.4.1.5040.1.2.9 | |||
wtWebGraphThermHygroTemp | 1.3.6.1.4.1.5040.1.2.9.1 | |||
wtWebGraphThermHygroSensors | 1.3.6.1.4.1.5040.1.2.9.1.1 | integer | read-only |
Number of sensors |
wtWebGraphThermHygroSensorTable | 1.3.6.1.4.1.5040.1.2.9.1.2 | no-access |
List of sensors. |
|
1.3.6.1.4.1.5040.1.2.9.1.2.1 | no-access |
List of sensor numbers. |
||
wtWebGraphThermHygroSensorNo | 1.3.6.1.4.1.5040.1.2.9.1.2.1.1 | integer | read-only |
Sensor number. |
wtWebGraphThermHygroTempValueTable | 1.3.6.1.4.1.5040.1.2.9.1.3 | no-access |
List of measurement values corresponding to the channel numbers. |
|
1.3.6.1.4.1.5040.1.2.9.1.3.1 | no-access |
Measurement values of the sensors. |
||
wtWebGraphThermHygroTempValue | 1.3.6.1.4.1.5040.1.2.9.1.3.1.1 | octet string | read-only |
Measurement value of the sensor, ASCII, 5 characters in length. |
wtWebGraphThermHygroBinaryTempValueTable | 1.3.6.1.4.1.5040.1.2.9.1.4 | no-access |
List of binary measurement values corresponding to the channel numbers. |
|
1.3.6.1.4.1.5040.1.2.9.1.4.1 | no-access |
Binary measurement values of the sensors. |
||
wtWebGraphThermHygroBinaryTempValue | 1.3.6.1.4.1.5040.1.2.9.1.4.1.1 | integer | read-only |
Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent, signed number, 0x4FFF6 indicates an invalid measured value. |
wtWebGraphThermHygroSessCntrl | 1.3.6.1.4.1.5040.1.2.9.2 | |||
wtWebGraphThermHygroSessCntrlPassword | 1.3.6.1.4.1.5040.1.2.9.2.1 | octet string | read-write |
Entering this password opens a session which is ended by writing a 1 to wtWebGraphThermHygroSessCntrlLogout. When read this variable provides a string of length zero. |
wtWebGraphThermHygroSessCntrlConfigMode | 1.3.6.1.4.1.5040.1.2.9.2.2 | integer | read-only |
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read. Enumeration: 'wtWebGraphThermHygroSessCntrl-NoSession': 0, 'wtWebGraphThermHygroSessCntrl-Session': 1. |
wtWebGraphThermHygroSessCntrlLogout | 1.3.6.1.4.1.5040.1.2.9.2.3 | integer | read-write |
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0. |
wtWebGraphThermHygroSessCntrlAdminPassword | 1.3.6.1.4.1.5040.1.2.9.2.4 | octet string | read-write |
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public. |
wtWebGraphThermHygroSessCntrlConfigPassword | 1.3.6.1.4.1.5040.1.2.9.2.5 | octet string | read-write |
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer. |
wtWebGraphThermHygroConfig | 1.3.6.1.4.1.5040.1.2.9.3 | |||
wtWebGraphThermHygroDevice | 1.3.6.1.4.1.5040.1.2.9.3.1 | |||
wtWebGraphThermHygroText | 1.3.6.1.4.1.5040.1.2.9.3.1.1 | |||
wtWebGraphThermHygroDeviceName | 1.3.6.1.4.1.5040.1.2.9.3.1.1.1 | octet string | read-write |
Name of the Webio, which is user definable. |
wtWebGraphThermHygroDeviceText | 1.3.6.1.4.1.5040.1.2.9.3.1.1.2 | octet string | read-write |
Description of the Webio, which is user definable. |
wtWebGraphThermHygroDeviceLocation | 1.3.6.1.4.1.5040.1.2.9.3.1.1.3 | octet string | read-write |
Description of the location of the Webio, which is user definable. |
wtWebGraphThermHygroDeviceContact | 1.3.6.1.4.1.5040.1.2.9.3.1.1.4 | octet string | read-write |
Contact address of the system operator of the Webio, which is user definable. |
wtWebGraphThermHygroTimeDate | 1.3.6.1.4.1.5040.1.2.9.3.1.2 | |||
wtWebGraphThermHygroTimeZone | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1 | |||
wtWebGraphThermHygroTzOffsetHrs | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.1 | integer | read-write |
Offset hours for the time zone (winter time) with respect to UTC. |
wtWebGraphThermHygroTzOffsetMin | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.2 | integer | read-write |
Offset minutes for the time zone (winter time) with respect to UTC. |
wtWebGraphThermHygroTzEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.3 | octet string | read-write |
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone |
wtWebGraphThermHygroStTzOffsetHrs | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.4 | integer | read-write |
Offset hours of the time zone (summer time) with respect to UTC. |
wtWebGraphThermHygroStTzOffsetMin | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.5 | integer | read-write |
Offset minutes of the time zone (summer time) with respect to UTC. |
wtWebGraphThermHygroStTzEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.6 | octet string | read-write |
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime |
wtWebGraphThermHygroStTzStartMonth | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.7 | integer | read-write |
Month in which the change is made from winter time to summer time. Enumeration: 'wtWebGraphThermHygroStartMonth-February': 2, 'wtWebGraphThermHygroStartMonth-January': 1, 'wtWebGraphThermHygroStartMonth-November': 11, 'wtWebGraphThermHygroStartMonth-June': 6, 'wtWebGraphThermHygroStartMonth-December': 12, 'wtWebGraphThermHygroStartMonth-April': 4, 'wtWebGraphThermHygroStartMonth-July': 7, 'wtWebGraphThermHygroStartMonth-September': 9, 'wtWebGraphThermHygroStartMonth-August': 8, 'wtWebGraphThermHygroStartMonth-October': 10, 'wtWebGraphThermHygroStartMonth-March': 3, 'wtWebGraphThermHygroStartMonth-May': 5. |
wtWebGraphThermHygroStTzStartMode | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.8 | integer | read-write |
Mode of the day of the week for which the change is made from winter time to summer time. Enumeration: 'wtWebGraphThermHygroStartMode-last': 5, 'wtWebGraphThermHygroStartMode-third': 3, 'wtWebGraphThermHygroStartMode-first': 1, 'wtWebGraphThermHygroStartMode-fourth': 4, 'wtWebGraphThermHygroStartMode-second': 2. |
wtWebGraphThermHygroStTzStartWday | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.9 | integer | read-write |
Day of the week on which the change is made from winter time to summer time Enumeration: 'wtWebGraphThermHygroStartWday-Thursday': 4, 'wtWebGraphThermHygroStartWday-Wednesday': 5, 'wtWebGraphThermHygroStartWday-Monday': 2, 'wtWebGraphThermHygroStartWday-Tuesday': 3, 'wtWebGraphThermHygroStartWday-Friday': 6, 'wtWebGraphThermHygroStartWday-Sunday': 1, 'wtWebGraphThermHygroStartWday-Saturday': 7. |
wtWebGraphThermHygroStTzStartHrs | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.10 | integer | read-write |
Hour in which the time zone is changed from winter to summer time with respect to UTC. |
wtWebGraphThermHygroStTzStartMin | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.11 | integer | read-write |
Minute in which the time zone is changed from winter to summer time with respect to UTC. |
wtWebGraphThermHygroStTzStopMonth | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.12 | integer | read-write |
Month in which the change is made from summer time to winter time. Enumeration: 'wtWebGraphThermHygroStopMonth-May': 5, 'wtWebGraphThermHygroStopMonth-February': 2, 'wtWebGraphThermHygroStopMonth-October': 10, 'wtWebGraphThermHygroStopMonth-January': 1, 'wtWebGraphThermHygroStopMonth-September': 9, 'wtWebGraphThermHygroStopMonth-December': 12, 'wtWebGraphThermHygroStopMonth-August': 8, 'wtWebGraphThermHygroStopMonth-November': 11, 'wtWebGraphThermHygroStopMonth-March': 3, 'wtWebGraphThermHygroStopMonth-June': 6, 'wtWebGraphThermHygroStopMonth-July': 7, 'wtWebGraphThermHygroStopMonth-April': 4. |
wtWebGraphThermHygroStTzStopMode | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.13 | integer | read-write |
Mode of the week day on which the change is made from summer time to winter time. Enumeration: 'wtWebGraphThermHygroStopMode-fourth': 4, 'wtWebGraphThermHygroStopMode-last': 5, 'wtWebGraphThermHygroStopMode-second': 2, 'wtWebGraphThermHygroStopMode-first': 1, 'wtWebGraphThermHygroStopMode-third': 3. |
wtWebGraphThermHygroStTzStopWday | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.14 | integer | read-write |
Day of the week on which the change is made from summer time to winter time. Enumeration: 'wtWebGraphThermHygroStopWday-Tuesday': 3, 'wtWebGraphThermHygroStopWday-Friday': 6, 'wtWebGraphThermHygroStopWday-Sunday': 1, 'wtWebGraphThermHygroStopWday-Thursday': 4, 'wtWebGraphThermHygroStopWday-Saturday': 7, 'wtWebGraphThermHygroStopWday-Wednesday': 5, 'wtWebGraphThermHygroStopWday-Monday': 2. |
wtWebGraphThermHygroStTzStopHrs | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.15 | integer | read-write |
Hour at which the time zone is changed from summer to winter time with respect to UTC. |
wtWebGraphThermHygroStTzStopMin | 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.16 | integer | read-write |
Minute at which the time zone is changed from summer to winter time with respect to UTC. |
wtWebGraphThermHygroTimeServer | 1.3.6.1.4.1.5040.1.2.9.3.1.2.2 | |||
wtWebGraphThermHygroTimeServer1 | 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.1 | octet string | read-write |
IP address or name of the 1st time server in ASCII |
wtWebGraphThermHygroTimeServer2 | 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.2 | octet string | read-write |
IP address or name of the 2nd time server in ASCII |
wtWebGraphThermHygroTsEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3 | octet string | read-write |
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server |
wtWebGraphThermHygroTsSyncTime | 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.4 | integer | read-write |
Daily synchronisation time with the time server (hour: 0-23). |
wtWebGraphThermHygroDeviceClock | 1.3.6.1.4.1.5040.1.2.9.3.1.2.3 | |||
wtWebGraphThermHygroClockHrs | 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.1 | integer | read-write |
Clock hours taking into account the time zone settings. |
wtWebGraphThermHygroClockMin | 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.2 | integer | read-write |
Clock minutes taking into account the time zone settings. |
wtWebGraphThermHygroClockDay | 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.3 | integer | read-write |
Date: Day of the month, taking into account the time zone settings. |
wtWebGraphThermHygroClockMonth | 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.4 | integer | read-write |
Date: Month, taking into account the time zone settings. Enumeration: 'wtWebGraphThermHygroClockMonth-October': 10, 'wtWebGraphThermHygroClockMonth-February': 2, 'wtWebGraphThermHygroClockMonth-May': 5, 'wtWebGraphThermHygroClockMonth-November': 11, 'wtWebGraphThermHygroClockMonth-March': 3, 'wtWebGraphThermHygroClockMonth-April': 4, 'wtWebGraphThermHygroClockMonth-January': 1, 'wtWebGraphThermHygroClockMonth-July': 7, 'wtWebGraphThermHygroClockMonth-June': 6, 'wtWebGraphThermHygroClockMonth-August': 8, 'wtWebGraphThermHygroClockMonth-September': 9, 'wtWebGraphThermHygroClockMonth-December': 12. |
wtWebGraphThermHygroClockYear | 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.5 | integer | read-write |
Date: Year, taking into account the time zone settings. |
wtWebGraphThermHygroBasic | 1.3.6.1.4.1.5040.1.2.9.3.1.3 | |||
wtWebGraphThermHygroNetwork | 1.3.6.1.4.1.5040.1.2.9.3.1.3.1 | |||
wtWebGraphThermHygroIpAddress | 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.1 | ipaddress | read-write |
IP address of the Webio |
wtWebGraphThermHygroSubnetMask | 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2 | ipaddress | read-write |
Subnet mask of the Webio |
wtWebGraphThermHygroGateway | 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.3 | ipaddress | read-write |
Gateway of the Webio |
wtWebGraphThermHygroDnsServer1 | 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.4 | octet string | read-write |
IP address of the 1st DNS server in ASCII |
wtWebGraphThermHygroDnsServer2 | 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.5 | octet string | read-write |
IP address of the 2nd DNS server in ASCII |
wtWebGraphThermHygroAddConfig | 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.6 | octet string | read-write |
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable |
wtWebGraphThermHygroHTTP | 1.3.6.1.4.1.5040.1.2.9.3.1.3.2 | |||
wtWebGraphThermHygroStartup | 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.1 | octet string | read-write |
Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time. |
wtWebGraphThermHygroGetHeaderEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.2 | octet string | read-write |
If this bit is set, every answer of a short form GET question will be lead by the IP-address and name of the device: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : GET Header enable |
wtWebGraphThermHygroHttpPort | 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3 | integer | read-write |
Definition of the standard HTML port (Default: 80). |
wtWebGraphThermHygroMail | 1.3.6.1.4.1.5040.1.2.9.3.1.3.3 | |||
wtWebGraphThermHygroMailAdName | 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.1 | octet string | read-write |
Device name for mail administration. |
wtWebGraphThermHygroMailReply | 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.2 | octet string | read-write |
Reply address for the mail server. |
wtWebGraphThermHygroMailServer | 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.3 | octet string | read-write |
Name or IP address of the mail server. |
wtWebioAn1MailEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4 | octet string | read-write |
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable |
wtWebGraphThermHygroMailAuthentication | 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5 | octet string | read-write |
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication |
wtWebGraphThermHygroMailAuthUser | 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.6 | octet string | read-write |
Name of the user to be authenticated. |
wtWebGraphThermHygroMailAuthPassword | 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.7 | octet string | read-write |
Authentication password. |
wtWebGraphThermHygroMailPop3Server | 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.8 | octet string | read-write |
Name or Ip-address of the POP3 Servers. |
wtWebGraphThermHygroSNMP | 1.3.6.1.4.1.5040.1.2.9.3.1.3.4 | |||
wtWebGraphThermHygroSnmpCommunityStringRead | 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.1 | octet string | read-write |
Community string read only |
wtWebGraphThermHygroSnmpCommunityStringReadWrite | 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.2 | octet string | read-write |
Community string read / write |
wtWebGraphThermHygroSystemTrapManagerIP | 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.3 | octet string | read-write |
Name or IP address of the TCP server which accepts the system trap. |
wtWebGraphThermHygroSystemTrapEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.4 | octet string | read-write |
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused |
wtWebGraphThermHygroSnmpEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5 | octet string | read-write |
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable |
wtWebGraphThermHygroSnmpCommunityStringTrap | 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.6 | octet string | read-write |
Community string send within traps. |
wtWebGraphThermHygroUDP | 1.3.6.1.4.1.5040.1.2.9.3.1.3.5 | |||
wtWebGraphThermHygroUdpPort | 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1 | integer | read-write |
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device. |
wtWebGraphThermHygroUdpEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.2 | octet string | read-write |
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable |
wtWebGraphThermHygroSyslog | 1.3.6.1.4.1.5040.1.2.9.3.1.3.6 | |||
wtWebGraphThermHygroSyslogServerIP | 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.1 | octet string | read-write |
Name or IP address of the Syslog server, which accepts the Syslog messgaes. |
wtWebGraphThermHygroSyslogServerPort | 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.2 | integer | read-write |
Portnumber of the Syslog servers, default 514. |
wtWebGraphThermHygroSyslogSystemMessagesEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.3 | octet string | read-write |
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused |
wtWebGraphThermHygroSyslogEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.4 | octet string | read-write |
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable |
wtWebGraphThermHygroFTP | 1.3.6.1.4.1.5040.1.2.9.3.1.3.7 | |||
wtWebGraphThermHygroFTPServerIP | 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.1 | octet string | read-write |
Name or IP address of the FTP server, which accepts the FTP messages. |
wtWebGraphThermHygroFTPServerControlPort | 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2 | integer | read-write |
Portnumber of the control port of the FTP server, default 21. |
wtWebGraphThermHygroFTPUserName | 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.3 | octet string | read-write |
FTP Loggin: user name. |
wtWebGraphThermHygroFTPPassword | 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.4 | octet string | read-write |
FTP Loggin: user password. |
wtWebGraphThermHygroFTPAccount | 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.5 | octet string | read-write |
FTP Loggin: name of account. |
wtWebGraphThermHygroFTPOption | 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.6 | octet string | read-write |
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable |
wtWebGraphThermHygroFTPEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.7 | octet string | read-write |
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable |
wtWebGraphThermHygroDatalogger | 1.3.6.1.4.1.5040.1.2.9.3.1.4 | |||
wtWebGraphThermHygroLoggerTimebase | 1.3.6.1.4.1.5040.1.2.9.3.1.4.1 | integer | read-write |
Time base of the data logger Enumeration: 'wtWebGraphThermHygroDatalogger-1Min': 1, 'wtWebGraphThermHygroDatalogger-60Min': 4, 'wtWebGraphThermHygroDatalogger-5Min': 2, 'wtWebGraphThermHygroDatalogger-15Min': 3. |
wtWebGraphThermHygroLoggerSensorSel | 1.3.6.1.4.1.5040.1.2.9.3.1.4.2 | octet string | read-write |
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
wtWebGraphThermHygroDisplaySensorSel | 1.3.6.1.4.1.5040.1.2.9.3.1.4.3 | octet string | read-write |
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
wtWebGraphThermHygroSensorColorTable | 1.3.6.1.4.1.5040.1.2.9.3.1.4.4 | no-access |
List of sensor colors for the praphical presentation. |
|
1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1 | no-access |
Index numbers of the sensors. |
||
wtWebGraphThermHygroSensorColor | 1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1.1 | octet string | read-write |
Color of the sensors at the praphical presention. |
wtWebGraphThermHygroAutoScaleEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.4.5 | octet string | read-write |
If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable |
wtWebGraphThermHygroVerticalUpperLimit | 1.3.6.1.4.1.5040.1.2.9.3.1.4.6 | octet string | read-write |
This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places. |
wtWebGraphThermHygroVerticalLowerLimit | 1.3.6.1.4.1.5040.1.2.9.3.1.4.7 | octet string | read-write |
This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places. |
wtWebGraphThermHygroHorizontalZoom | 1.3.6.1.4.1.5040.1.2.9.3.1.4.8 | integer | read-write |
Defines the default zoom stage, if no auto scaling is selected. Enumeration: 'wtWebGraphThermHygroZoom-25days': 6, 'wtWebGraphThermHygroZoom-75min': 2, 'wtWebGraphThermHygroZoom-5hrs': 3, 'wtWebGraphThermHygroZoom-25min': 1, 'wtWebGraphThermHygroZoom-30hrs': 4, 'wtWebGraphThermHygroZoom-5days': 5. |
wtWebGraphThermHygroAlarm | 1.3.6.1.4.1.5040.1.2.9.3.1.5 | |||
wtWebGraphThermHygroAlarmCount | 1.3.6.1.4.1.5040.1.2.9.3.1.5.1 | integer | read-only |
Number of independent alarms. |
wtWebGraphThermHygroAlarmIfTable | 1.3.6.1.4.1.5040.1.2.9.3.1.5.2 | no-access |
List of alarm indices. |
|
1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1 | no-access |
Numbers of the alarms. |
||
wtWebGraphThermHygroAlarmNo | 1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1.1 | integer | read-only |
Alarm number. |
wtWebGraphThermHygroAlarmTable | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3 | no-access |
List of settings depending on the alarm number. |
|
1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1 | no-access |
Alarm parameters of the individual alarms. |
||
wtWebGraphThermHygroAlarmTrigger | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.1 | octet string | read-write |
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
wtWebGraphThermHygroAlarmMin | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.2 | octet string | read-write |
Minimum temperature in degrees with maximum 2 decimal places. |
wtWebGraphThermHygroAlarmMax | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.3 | octet string | read-write |
Maximum temperature in degrees with maximum 2 decimal places. |
wtWebGraphThermHygroAlarmHysteresis | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.4 | octet string | read-write |
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places. |
wtWebGraphThermHygroAlarmDelay | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.5 | octet string | read-write |
Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes). |
wtWebGraphThermHygroAlarmInterval | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.6 | octet string | read-write |
Send interval for alarm messages. |
wtWebGraphThermHygroAlarmEnable | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.7 | octet string | read-write |
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
wtWebGraphThermHygroAlarmEMailAddr | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8 | octet string | read-write |
E-Mail address for sending the alarm mail to. |
wtWebGraphThermHygroAlarmMailSubject | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.9 | octet string | read-write |
Subject line for alarm mail. |
wtWebGraphThermHygroAlarmMailText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.10 | octet string | read-write |
Alarm mail text: |
wtWebGraphThermHygroAlarmManagerIP | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.11 | octet string | read-write |
Name or IP address of the SNMP Manager which accepts the trap. |
wtWebGraphThermHygroAlarmTrapText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.12 | octet string | read-write |
This text is sent in the trap body. |
wtWebGraphThermHygroAlarmMailOptions | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.13 | octet string | read-write |
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
wtWebGraphThermHygroAlarmTcpIpAddr | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.14 | octet string | read-write |
Name or IP address of the TCP server which accepts the trap. |
wtWebGraphThermHygroAlarmTcpPort | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15 | integer | read-write |
Port number of the TCP server which accepts the trap. |
wtWebGraphThermHygroAlarmTcpText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.16 | octet string | read-write |
This text is sent in the TCP trap body. |
wtWebGraphThermHygroAlarmClearMailSubject | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.17 | octet string | read-write |
Subject line for alarm clear mail. |
wtWebGraphThermHygroAlarmClearMailText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.18 | octet string | read-write |
Alarm clear mail text: |
wtWebGraphThermHygroAlarmClearTrapText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.19 | octet string | read-write |
This text is sent in the trap body. |
wtWebGraphThermHygroAlarmClearTcpText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.20 | octet string | read-write |
This text is sent in the TCP trap body. |
wtWebGraphThermHygroAlarmDeltaTemp | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.21 | octet string | read-write |
Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes. |
wtWebGraphThermHygroAlarmRHMin | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.22 | octet string | read-write |
Minimum rel. Humidity in percent with maximum 2 decimal places. |
wtWebGraphThermHygroAlarmRHMax | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.23 | octet string | read-write |
Maximum rel.Humidity in percent with maximum 2 decimal places. |
wtWebGraphThermHygroAlarmRHHysteresis | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.24 | octet string | read-write |
Hysterese rel. Humidity in percent with maximum 2 decimal places. |
wtWebGraphThermHygroAlarmAHMin | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.25 | octet string | read-write |
Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. |
wtWebGraphThermHygroAlarmAHMax | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.26 | octet string | read-write |
Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. |
wtWebGraphThermHygroAlarmSyslogIpAddr | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.27 | ipaddress | read-write |
IP address of the syslog server to which the Webio device should send syslog messages. |
wtWebGraphThermHygroAlarmSyslogPort | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28 | integer | read-write |
Port number of the syslog server to which the Webio device should send syslog messages. |
wtWebGraphThermHygroAlarmSyslogText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.29 | octet string | read-write |
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
wtWebGraphThermHygroAlarmSyslogClearText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30 | octet string | read-write |
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
wtWebGraphThermHygroAlarmFtpDataPort | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.31 | octet string | read-write |
Local data port: 1..65535 or AUTO: the next free port will be assigned. |
wtWebGraphThermHygroAlarmFtpFileName | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.32 | octet string | read-write |
Name of the file including path informations. |
wtWebGraphThermHygroAlarmFtpText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.33 | octet string | read-write |
Message text to store on the FTP server. |
wtWebGraphThermHygroAlarmFtpClearText | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.34 | octet string | read-write |
Alarm clear message to store on the FTP server. |
wtWebGraphThermHygroAlarmFtpOptions | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.35 | octet string | read-write |
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused |
wtWebGraphThermHygroAlarmTimerCron | 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.36 | octet string | read-write |
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute). |
wtWebGraphThermHygroPorts | 1.3.6.1.4.1.5040.1.2.9.3.2 | |||
wtWebGraphThermHygroPortTable | 1.3.6.1.4.1.5040.1.2.9.3.2.1 | no-access |
List of settings depending on the sensor number. |
|
1.3.6.1.4.1.5040.1.2.9.3.2.1.1 | no-access |
Sensor parameters for the individual sensors. |
||
wtWebGraphThermHygroPortName | 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.1 | octet string | read-write |
Name of the sensor. |
wtWebGraphThermHygroPortText | 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.2 | octet string | read-write |
Description of the sensor. |
wtWebGraphThermHygroPortOffset1 | 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.3 | octet string | read-write |
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1. |
wtWebGraphThermHygroPortTemperature1 | 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.4 | octet string | read-write |
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
wtWebGraphThermHygroPortOffset2 | 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.5 | octet string | read-write |
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2. |
wtWebGraphThermHygroPortTemperature2 | 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.6 | octet string | read-write |
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
wtWebGraphThermHygroPortComment | 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.7 | octet string | read-write |
Offset calibration: informations of date, name of operator, reference devices. |
wtWebGraphThermHygroPortSensorSelect | 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8 | octet string | read-write |
Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: unused Binary coded options for sensor 2: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : W&T Sensor rel. humidity (default) Bit 1 : Skalar 0-2.5V Bit 2 : Disconnect Bit 3-7: unused |
wtWebGraphThermHygroManufact | 1.3.6.1.4.1.5040.1.2.9.3.3 | |||
wtWebGraphThermHygroMfName | 1.3.6.1.4.1.5040.1.2.9.3.3.1 | octet string | read-write |
Manufacturer company name |
wtWebGraphThermHygroMfAddr | 1.3.6.1.4.1.5040.1.2.9.3.3.2 | octet string | read-write |
Manufacturer address. |
wtWebGraphThermHygroMfHotline | 1.3.6.1.4.1.5040.1.2.9.3.3.3 | octet string | read-write |
Manufacturer hotline. |
wtWebGraphThermHygroMfInternet | 1.3.6.1.4.1.5040.1.2.9.3.3.4 | octet string | read-write |
Manufacturer Internet address. |
wtWebGraphThermHygroMfDeviceTyp | 1.3.6.1.4.1.5040.1.2.9.3.3.5 | octet string | read-write |
Manufacturer device name (model number). |
wtWebGraphThermHygroMfOrderNo | 1.3.6.1.4.1.5040.1.2.9.3.3.6 | octet string | read-write |
Manufacturer part number. |
wtWebGraphThermHygroDiag | 1.3.6.1.4.1.5040.1.2.9.4 | |||
wtWebGraphThermHygroDiagErrorCount | 1.3.6.1.4.1.5040.1.2.9.4.1 | integer | read-only |
Number of entries in the error memory. |
wtWebGraphThermHygroDiagBinaryError | 1.3.6.1.4.1.5040.1.2.9.4.2 | octet string | read-only |
Error causes coded bit-by-bit. |
wtWebGraphThermHygroDiagErrorIndex | 1.3.6.1.4.1.5040.1.2.9.4.3 | integer | read-write |
The value of this variable is used as an index to read an error massege from wtWebGraphThermHygroDiagErrorMessage. Errors are numbered from 1 to wtWebGraphThermHygroDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphThermHygroDiagErrorMessage. |
wtWebGraphThermHygroDiagErrorMessage | 1.3.6.1.4.1.5040.1.2.9.4.4 | octet string | read-only |
Using wtWebGraphThermHygroDiagErrorIndex as an index, the appropriate message is available. |
wtWebGraphThermHygroDiagErrorClear | 1.3.6.1.4.1.5040.1.2.9.4.5 | integer | read-write |
Writing 1 into this variable clears all diagnosis messages. |
wtWebGraphThermHygroAlert1 | 1.3.6.1.4.1.5040.1.2.90.31 |
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert2 | 1.3.6.1.4.1.5040.1.2.90.32 |
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert3 | 1.3.6.1.4.1.5040.1.2.90.33 |
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert4 | 1.3.6.1.4.1.5040.1.2.90.34 |
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert5 | 1.3.6.1.4.1.5040.1.2.90.35 |
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert6 | 1.3.6.1.4.1.5040.1.2.90.36 |
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert7 | 1.3.6.1.4.1.5040.1.2.90.37 |
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert8 | 1.3.6.1.4.1.5040.1.2.90.38 |
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert9 | 1.3.6.1.4.1.5040.1.2.90.91 |
This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert10 | 1.3.6.1.4.1.5040.1.2.90.92 |
This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert11 | 1.3.6.1.4.1.5040.1.2.90.93 |
This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert12 | 1.3.6.1.4.1.5040.1.2.90.94 |
This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert13 | 1.3.6.1.4.1.5040.1.2.90.95 |
This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert14 | 1.3.6.1.4.1.5040.1.2.90.96 |
This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert15 | 1.3.6.1.4.1.5040.1.2.90.97 |
This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlert16 | 1.3.6.1.4.1.5040.1.2.90.98 |
This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled. |
||
wtWebGraphThermHygroAlertDiag | 1.3.6.1.4.1.5040.1.2.90.110 |
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled. |