WebGraph-Thermo-Hygrometer-MIB: View SNMP OID List / Download MIB

VENDOR: WIESEMANN N THEIS


 Home MIB: WebGraph-Thermo-Hygrometer-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wut 1.3.6.1.4.1.5040
           wtComServer 1.3.6.1.4.1.5040.1
               wtWebio 1.3.6.1.4.1.5040.1.2
                   wtWebGraphThermHygro 1.3.6.1.4.1.5040.1.2.9
                       wtWebGraphThermHygroTemp 1.3.6.1.4.1.5040.1.2.9.1
                           wtWebGraphThermHygroSensors 1.3.6.1.4.1.5040.1.2.9.1.1 integer read-only
Anzahl der Sensoren
                           wtWebGraphThermHygroSensorTable 1.3.6.1.4.1.5040.1.2.9.1.2 no-access
Liste der Sensoren.
                               wtWebGraphThermHygroSensorEntry 1.3.6.1.4.1.5040.1.2.9.1.2.1 no-access
Nummern der Sensoren.
                                   wtWebGraphThermHygroSensorNo 1.3.6.1.4.1.5040.1.2.9.1.2.1.1 integer read-only
Nummer des Sensors.
                           wtWebGraphThermHygroTempValueTable 1.3.6.1.4.1.5040.1.2.9.1.3 no-access
Liste Sensormesswerte korrespondiernd zu den Kanalnummern.
                               wtWebGraphThermHygroTempValueEntry 1.3.6.1.4.1.5040.1.2.9.1.3.1 no-access
Messwerte der Sensoren.
                                   wtWebGraphThermHygroTempValue 1.3.6.1.4.1.5040.1.2.9.1.3.1.1 octet string read-only
Messwert des Sensors, ASCII, 5 Zeichen lang.
                           wtWebGraphThermHygroBinaryTempValueTable 1.3.6.1.4.1.5040.1.2.9.1.4 no-access
Liste binrer Messwerte korrespondiernd zu den Kanalnummern.
                               wtWebGraphThermHygroBinaryTempValueEntry 1.3.6.1.4.1.5040.1.2.9.1.4.1 no-access
Binre Messwerte der Sensoren.
                                   wtWebGraphThermHygroBinaryTempValue 1.3.6.1.4.1.5040.1.2.9.1.4.1.1 integer read-only
Binrer Messwert des Sensors in 1/10 Grad Celcius oder 1/10 Prozent, vorzeichenbehaftete Zahl, der Wert 0x4FFF6 zeigt einen ungltigen Messwert an.
                       wtWebGraphThermHygroSessCntrl 1.3.6.1.4.1.5040.1.2.9.2
                           wtWebGraphThermHygroSessCntrlPassword 1.3.6.1.4.1.5040.1.2.9.2.1 octet string read-write
Durch Eintrag diese Passworts wird eine Session erffnet, die durch Schreiben einer 1 in wtWebGraphThermHygroSessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der Lnge Null.
                           wtWebGraphThermHygroSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.9.2.2 integer read-only
Wenn sich das Gert im SNMP-Konfigurationsmodus befindet, wird der Wert 1 zurckgeliefert, ansonsten 0. Ist der ausgelesene Wert 0 obwohl das Passwort geschrieben wurde, befindet sich das Gert bereits im Configmodus und die Variablen knnen nur gelesen werden. Enumeration: 'wtWebGraphThermHygroSessCntrl-NoSession': 0, 'wtWebGraphThermHygroSessCntrl-Session': 1.
                           wtWebGraphThermHygroSessCntrlLogout 1.3.6.1.4.1.5040.1.2.9.2.3 integer read-write
Wenn sich das Gert im Konfigurationsmodus befindet und die Session wurde von diesem SNMP Manager erffnet, kann durch Schreiben einer 1 in diese Variable die Session beendet werden und alle Parameter werden gespeichert. Durch Schreiben einer 2 werden alle Eingaben wieder verworfen. Gelesen liefert diese Variable den Wert 0.
                           wtWebGraphThermHygroSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.9.2.4 octet string read-write
Dieses Passwort schtzt den Zugang der Variablen mit Administratorrechten. Es kann nur vom Administrator verndert werden. Wurde kein Passwort vergeben so ist public das gltige Passwort. Gelesen liefert diese Variable einen Null-Pointer.
                           wtWebGraphThermHygroSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.9.2.5 octet string read-write
Dieses Passwort schtzt den Zugang der Variablen mit Configuratorrechten. Es kann vom Administrator und vom Configurator verndert werden. Wurde kein Passwort vergeben so ist public das gltige Passwort.Gelesen liefert diese Variable einen Null-Pointer.
                       wtWebGraphThermHygroConfig 1.3.6.1.4.1.5040.1.2.9.3
                           wtWebGraphThermHygroDevice 1.3.6.1.4.1.5040.1.2.9.3.1
                               wtWebGraphThermHygroText 1.3.6.1.4.1.5040.1.2.9.3.1.1
                                   wtWebGraphThermHygroDeviceName 1.3.6.1.4.1.5040.1.2.9.3.1.1.1 octet string read-write
Name des Webio's, der userdefinierbar ist.
                                   wtWebGraphThermHygroDeviceText 1.3.6.1.4.1.5040.1.2.9.3.1.1.2 octet string read-write
Beschreibung des Webio's, die userdefinierbar ist.
                                   wtWebGraphThermHygroDeviceLocation 1.3.6.1.4.1.5040.1.2.9.3.1.1.3 octet string read-write
Aufstellort des Webio's, die userdefinierbar ist.
                                   wtWebGraphThermHygroDeviceContact 1.3.6.1.4.1.5040.1.2.9.3.1.1.4 octet string read-write
Kontaktadresse im Servicefall des Webio's, die userdefinierbar ist.
                               wtWebGraphThermHygroTimeDate 1.3.6.1.4.1.5040.1.2.9.3.1.2
                                   wtWebGraphThermHygroTimeZone 1.3.6.1.4.1.5040.1.2.9.3.1.2.1
                                       wtWebGraphThermHygroTzOffsetHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.1 integer read-write
Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC.
                                       wtWebGraphThermHygroTzOffsetMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.2 integer read-write
Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC.
                                       wtWebGraphThermHygroTzEnable 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.3 octet string read-write
Binr kodierte Bedingung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Apply Timezone
                                       wtWebGraphThermHygroStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.4 integer read-write
Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC.
                                       wtWebGraphThermHygroStTzOffsetMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.5 integer read-write
Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC.
                                       wtWebGraphThermHygroStTzEnable 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.6 octet string read-write
Binr kodierte Bedingung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Apply Summertime
                                       wtWebGraphThermHygroStTzStartMonth 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.7 integer read-write
Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird. Enumeration: 'wtWebGraphThermHygroStartMonth-February': 2, 'wtWebGraphThermHygroStartMonth-January': 1, 'wtWebGraphThermHygroStartMonth-November': 11, 'wtWebGraphThermHygroStartMonth-June': 6, 'wtWebGraphThermHygroStartMonth-December': 12, 'wtWebGraphThermHygroStartMonth-April': 4, 'wtWebGraphThermHygroStartMonth-July': 7, 'wtWebGraphThermHygroStartMonth-September': 9, 'wtWebGraphThermHygroStartMonth-August': 8, 'wtWebGraphThermHygroStartMonth-October': 10, 'wtWebGraphThermHygroStartMonth-March': 3, 'wtWebGraphThermHygroStartMonth-May': 5.
                                       wtWebGraphThermHygroStTzStartMode 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.8 integer read-write
Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird. Enumeration: 'wtWebGraphThermHygroStartMode-last': 5, 'wtWebGraphThermHygroStartMode-third': 3, 'wtWebGraphThermHygroStartMode-first': 1, 'wtWebGraphThermHygroStartMode-second': 2, 'wtWebGraphThermHygroStartMode-fourth': 4.
                                       wtWebGraphThermHygroStTzStartWday 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.9 integer read-write
Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird Enumeration: 'wtWebGraphThermHygroStartWday-Thursday': 4, 'wtWebGraphThermHygroStartWday-Wednesday': 5, 'wtWebGraphThermHygroStartWday-Monday': 2, 'wtWebGraphThermHygroStartWday-Tuesday': 3, 'wtWebGraphThermHygroStartWday-Friday': 6, 'wtWebGraphThermHygroStartWday-Sunday': 1, 'wtWebGraphThermHygroStartWday-Saturday': 7.
                                       wtWebGraphThermHygroStTzStartHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.10 integer read-write
Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC umgestellt wird.
                                       wtWebGraphThermHygroStTzStartMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.11 integer read-write
Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC umgestellt wird.
                                       wtWebGraphThermHygroStTzStopMonth 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.12 integer read-write
Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird. Enumeration: 'wtWebGraphThermHygroStopMonth-March': 3, 'wtWebGraphThermHygroStopMonth-February': 2, 'wtWebGraphThermHygroStopMonth-October': 10, 'wtWebGraphThermHygroStopMonth-January': 1, 'wtWebGraphThermHygroStopMonth-July': 7, 'wtWebGraphThermHygroStopMonth-December': 12, 'wtWebGraphThermHygroStopMonth-August': 8, 'wtWebGraphThermHygroStopMonth-November': 11, 'wtWebGraphThermHygroStopMonth-May': 5, 'wtWebGraphThermHygroStopMonth-June': 6, 'wtWebGraphThermHygroStopMonth-September': 9, 'wtWebGraphThermHygroStopMonth-April': 4.
                                       wtWebGraphThermHygroStTzStopMode 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.13 integer read-write
Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird. Enumeration: 'wtWebGraphThermHygroStopMode-second': 2, 'wtWebGraphThermHygroStopMode-third': 3, 'wtWebGraphThermHygroStopMode-fourth': 4, 'wtWebGraphThermHygroStopMode-first': 1, 'wtWebGraphThermHygroStopMode-last': 5.
                                       wtWebGraphThermHygroStTzStopWday 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.14 integer read-write
Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird. Enumeration: 'wtWebGraphThermHygroStopWday-Tuesday': 3, 'wtWebGraphThermHygroStopWday-Friday': 6, 'wtWebGraphThermHygroStopWday-Sunday': 1, 'wtWebGraphThermHygroStopWday-Thursday': 4, 'wtWebGraphThermHygroStopWday-Saturday': 7, 'wtWebGraphThermHygroStopWday-Wednesday': 5, 'wtWebGraphThermHygroStopWday-Monday': 2.
                                       wtWebGraphThermHygroStTzStopHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.15 integer read-write
Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC umgestellt wird.
                                       wtWebGraphThermHygroStTzStopMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.16 integer read-write
Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC umgestellt wird.
                                   wtWebGraphThermHygroTimeServer 1.3.6.1.4.1.5040.1.2.9.3.1.2.2
                                       wtWebGraphThermHygroTimeServer1 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.1 octet string read-write
IP-Adresse oder Name des 1. Time Servers in ASCII
                                       wtWebGraphThermHygroTimeServer2 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.2 octet string read-write
IP-Adresse oder Name des 2. Time Servers in ASCII
                                       wtWebGraphThermHygroTsEnable 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3 octet string read-write
Binr kodierte Bedingung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Apply Time Server
                                       wtWebGraphThermHygroTsSyncTime 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.4 integer read-write
Die Abfrage der Timeserver erfolgt zu dieser vollen Stunde (0-23).
                                   wtWebGraphThermHygroDeviceClock 1.3.6.1.4.1.5040.1.2.9.3.1.2.3
                                       wtWebGraphThermHygroClockHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.1 integer read-write
Uhrzeit Stunde, unter Bercksichtigung der Zeitzoneneinstellungen.
                                       wtWebGraphThermHygroClockMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.2 integer read-write
Uhrzeit Minute, unter Bercksichtigung der Zeitzoneneinstellungen.
                                       wtWebGraphThermHygroClockDay 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.3 integer read-write
Datum: Tag des Monats, unter Bercksichtigung der Zeitzoneneinstellungen.
                                       wtWebGraphThermHygroClockMonth 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.4 integer read-write
Datum: Monat, unter Bercksichtigung der Zeitzoneneinstellungen. Enumeration: 'wtWebGraphThermHygroClockMonth-October': 10, 'wtWebGraphThermHygroClockMonth-February': 2, 'wtWebGraphThermHygroClockMonth-May': 5, 'wtWebGraphThermHygroClockMonth-November': 11, 'wtWebGraphThermHygroClockMonth-March': 3, 'wtWebGraphThermHygroClockMonth-April': 4, 'wtWebGraphThermHygroClockMonth-January': 1, 'wtWebGraphThermHygroClockMonth-July': 7, 'wtWebGraphThermHygroClockMonth-June': 6, 'wtWebGraphThermHygroClockMonth-August': 8, 'wtWebGraphThermHygroClockMonth-September': 9, 'wtWebGraphThermHygroClockMonth-December': 12.
                                       wtWebGraphThermHygroClockYear 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.5 integer read-write
Datum: Jahr, unter Bercksichtigung der Zeitzoneneinstellungen.
                               wtWebGraphThermHygroBasic 1.3.6.1.4.1.5040.1.2.9.3.1.3
                                   wtWebGraphThermHygroNetwork 1.3.6.1.4.1.5040.1.2.9.3.1.3.1
                                       wtWebGraphThermHygroIpAddress 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.1 ipaddress read-write
IP-Adresse des Webio's
                                       wtWebGraphThermHygroSubnetMask 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2 ipaddress read-write
Subnetmask des Webio's
                                       wtWebGraphThermHygroGateway 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.3 ipaddress read-write
Gateway des Webio's
                                       wtWebGraphThermHygroDnsServer1 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.4 octet string read-write
IP-Adresse des 1. DNS Servers in ASCII
                                       wtWebGraphThermHygroDnsServer2 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.5 octet string read-write
IP-Adresse des 2. DNS Servers in ASCII
                                       wtWebGraphThermHygroAddConfig 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.6 octet string read-write
Zusatzkonfiguration (1=EIN): Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: BOOTP disable
                                   wtWebGraphThermHygroHTTP 1.3.6.1.4.1.5040.1.2.9.3.1.3.2
                                       wtWebGraphThermHygroStartup 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.1 octet string read-write
Legt die Startseite fest, nur eine Auswahl zulssig: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
                                       wtWebGraphThermHygroGetHeaderEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.2 octet string read-write
Wenn freigeschaltet, wird eine Erkennungssequenz nach jeder GET-Anfrage der Antwort vorangestellt: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : GET Header enable
                                       wtWebGraphThermHygroHttpPort 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3 integer read-write
HTTP Port, an den die TCP-Anfragen gesendet werden knnen (Default: 80).
                                   wtWebGraphThermHygroMail 1.3.6.1.4.1.5040.1.2.9.3.1.3.3
                                       wtWebGraphThermHygroMailAdName 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.1 octet string read-write
Gertename fr die Mail-Administration.
                                       wtWebGraphThermHygroMailReply 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.2 octet string read-write
Reply-Adresse fr den Mailserver.
                                       wtWebGraphThermHygroMailServer 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.3 octet string read-write
Name oder Ip-Adresse des Mailservers.
                                       wtWebGraphThermHygroMailEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4 octet string read-write
Erlaubt das versenden von Mails: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Mail enable
                                       wtWebGraphThermHygroMailAuthentication 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5 octet string read-write
Auswahl des Authenticationmodi: die OCTETS werden bitweise interpretiert, es darf nur ein Bit gesetzt sein. Bit 0 entspricht dem LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4: Bit 3-7: ungenutzt Bit 2 : POP3 vor SMTP Bit 1 : ESMTP, Authentifizierung Bit 0 : SMTP, keine Authentifizierung
                                       wtWebGraphThermHygroMailAuthUser 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.6 octet string read-write
Name des Postfaches / Postfachusers.
                                       wtWebGraphThermHygroMailAuthPassword 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.7 octet string read-write
Passwort zur Identifizierung des Users.
                                       wtWebGraphThermHygroMailPop3Server 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.8 octet string read-write
Name oder Ip-Adresse des POP3 Servers.
                                   wtWebGraphThermHygroSNMP 1.3.6.1.4.1.5040.1.2.9.3.1.3.4
                                       wtWebGraphThermHygroSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.1 octet string read-write
Community string read only
                                       wtWebGraphThermHygroSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.2 octet string read-write
Community string read / write
                                       wtWebGraphThermHygroSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.3 octet string read-write
Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt.
                                       wtWebGraphThermHygroSystemTrapEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.4 octet string read-write
Binr kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: ungenutzt
                                       wtWebGraphThermHygroSnmpEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5 octet string read-write
Bit 0 schaltet SNMP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : SNMP enable
                                       wtWebGraphThermHygroSnmpCommunityStringTrap 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.6 octet string read-write
Community string der Traps.
                                   wtWebGraphThermHygroUDP 1.3.6.1.4.1.5040.1.2.9.3.1.3.5
                                       wtWebGraphThermHygroUdpPort 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1 integer read-write
Udp Port, an den die Udp-Anfragen GET Single gesendet werden knnen
                                       wtWebGraphThermHygroUdpEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.2 octet string read-write
Schaltet UDP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : UDP enable
                                   wtWebGraphThermHygroSyslog 1.3.6.1.4.1.5040.1.2.9.3.1.3.6
                                       wtWebGraphThermHygroSyslogServerIP 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.1 octet string read-write
Name oder IP-Adresse des Syslog-Servers, der die Syslog-Nachricht entgegen nimmt.
                                       wtWebGraphThermHygroSyslogServerPort 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.2 integer read-write
Portnummer des Syslog-Servers, default ist 514.
                                       wtWebGraphThermHygroSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.3 octet string read-write
Binr kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: ungenutzt
                                       wtWebGraphThermHygroSyslogEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.4 octet string read-write
Bit 0 schaltet Syslog frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Syslog enable
                                   wtWebGraphThermHygroFTP 1.3.6.1.4.1.5040.1.2.9.3.1.3.7
                                       wtWebGraphThermHygroFTPServerIP 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.1 octet string read-write
Name oder IP-Adresse des FTP-Servers, der die FTP-Nachricht entgegen nimmt.
                                       wtWebGraphThermHygroFTPServerControlPort 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2 integer read-write
Portnummer des Kontrollports des FTP-Servers, default ist 21.
                                       wtWebGraphThermHygroFTPUserName 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.3 octet string read-write
FTP Loggin: Name des Anwenders.
                                       wtWebGraphThermHygroFTPPassword 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.4 octet string read-write
FTP Loggin: Passwort des Anwenders.
                                       wtWebGraphThermHygroFTPAccount 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.5 octet string read-write
FTP Loggin: Account-Name des Anwenderkontos.
                                       wtWebGraphThermHygroFTPOption 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.6 octet string read-write
Bit 0 schaltet den FTP Server in den Passiv-Modus, der Client kontrolliert die Datenverbindung allein: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : PASV enable
                                       wtWebGraphThermHygroFTPEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.7 octet string read-write
Bit 0 schaltet FTP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : FTP enable
                               wtWebGraphThermHygroDatalogger 1.3.6.1.4.1.5040.1.2.9.3.1.4
                                   wtWebGraphThermHygroLoggerTimebase 1.3.6.1.4.1.5040.1.2.9.3.1.4.1 integer read-write
Zeitbasis des Dataloggers Enumeration: 'wtWebGraphThermHygroDatalogger-1Min': 1, 'wtWebGraphThermHygroDatalogger-15Min': 3, 'wtWebGraphThermHygroDatalogger-60Min': 4, 'wtWebGraphThermHygroDatalogger-5Min': 2.
                                   wtWebGraphThermHygroLoggerSensorSel 1.3.6.1.4.1.5040.1.2.9.3.1.4.2 octet string read-write
Binr kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Sensor 1 Bit 1 : Sensor 2 Bit 2-7: ungenutzt
                                   wtWebGraphThermHygroDisplaySensorSel 1.3.6.1.4.1.5040.1.2.9.3.1.4.3 octet string read-write
Die hier ausgewhlten Sensoren werden grafisch angezeigt: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: ungenutzt
                                   wtWebGraphThermHygroSensorColorTable 1.3.6.1.4.1.5040.1.2.9.3.1.4.4 no-access
Liste der Sensorfarben in der grafischen Darstellung.
                                       wtWebGraphThermHygroSensorColorEntry 1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1 no-access
Nummern der Sensoren.
                                           wtWebGraphThermHygroSensorColor 1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1.1 octet string read-write
Farbe des Sensors in der grafischen Darstellung.
                                   wtWebGraphThermHygroAutoScaleEnable 1.3.6.1.4.1.5040.1.2.9.3.1.4.5 octet string read-write
Bit 0 schaltet Vertical Auto Scale frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Auto Scale enable
                                   wtWebGraphThermHygroVerticalUpperLimit 1.3.6.1.4.1.5040.1.2.9.3.1.4.6 octet string read-write
Definiert die maximal sichtbare Temperatur fr die grafische Darstellung. Temperatur in Grad mit maximal 2 Nachkommastellen.
                                   wtWebGraphThermHygroVerticalLowerLimit 1.3.6.1.4.1.5040.1.2.9.3.1.4.7 octet string read-write
Definiert die Minal sichtbare Temperatur fr die grafische Darstellung. Temperatur in Grad mit maximal 2 Nachkommastellen.
                                   wtWebGraphThermHygroHorizontalZoom 1.3.6.1.4.1.5040.1.2.9.3.1.4.8 integer read-write
Definiert den default Zoom. Enumeration: 'wtWebGraphThermHygroZoom-5Tage': 5, 'wtWebGraphThermHygroZoom-5Std': 3, 'wtWebGraphThermHygroZoom-75Min': 2, 'wtWebGraphThermHygroZoom-30Std': 4, 'wtWebGraphThermHygroZoom-25Min': 1, 'wtWebGraphThermHygroZoom-25Tage': 6.
                               wtWebGraphThermHygroAlarm 1.3.6.1.4.1.5040.1.2.9.3.1.5
                                   wtWebGraphThermHygroAlarmCount 1.3.6.1.4.1.5040.1.2.9.3.1.5.1 integer read-only
Anzahl der unabhngigen Alarme.
                                   wtWebGraphThermHygroAlarmIfTable 1.3.6.1.4.1.5040.1.2.9.3.1.5.2 no-access
Liste der Alarmindizes.
                                       wtWebGraphThermHygroAlarmIfEntry 1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1 no-access
Nummern der Alarme.
                                           wtWebGraphThermHygroAlarmNo 1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1.1 integer read-only
Nummer des Alarms.
                                   wtWebGraphThermHygroAlarmTable 1.3.6.1.4.1.5040.1.2.9.3.1.5.3 no-access
Liste der Einstellungen abhngig von der Alarmnummer.
                                       wtWebGraphThermHygroAlarmEntry 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1 no-access
Alarm-Parameter der einzelnen Alarme.
                                           wtWebGraphThermHygroAlarmTrigger 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.1 octet string read-write
Binr kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Bit 3: Sensor lost Bit 4-7 ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: ungenutzt
                                           wtWebGraphThermHygroAlarmMin 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.2 octet string read-write
Minimum Temperatur in Grad mit maximal 2 Nachkommastellen.
                                           wtWebGraphThermHygroAlarmMax 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.3 octet string read-write
Maximum Temperatur in Grad mit maximal 2 Nachkommastellen.
                                           wtWebGraphThermHygroAlarmHysteresis 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.4 octet string read-write
Bei berschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst. wird der Alarm gelscht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen.
                                           wtWebGraphThermHygroAlarmDelay 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.5 octet string read-write
Der Alarm wird erst ausgelst, wenn fr die Dauer dieser Zeit die Alarmbedingungen erfllt sind (Zeit in Minuten).
                                           wtWebGraphThermHygroAlarmInterval 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.6 octet string read-write
Sendeintervall von Alarmmeldungen.
                                           wtWebGraphThermHygroAlarmEnable 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.7 octet string read-write
Binr kodierte Alarmfreischaltung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable
                                           wtWebGraphThermHygroAlarmEMailAddr 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8 octet string read-write
E-Mail Adresse, an die die Alarmmail gesendet werden soll.
                                           wtWebGraphThermHygroAlarmMailSubject 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.9 octet string read-write
Betreffzeile der Alarmmail.
                                           wtWebGraphThermHygroAlarmMailText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.10 octet string read-write
Text der Alarmmail: liefert die aktuelle Temperatur; n = 1..8. liefert die aktuelle Zeit.
                                           wtWebGraphThermHygroAlarmManagerIP 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.11 octet string read-write
Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt.
                                           wtWebGraphThermHygroAlarmTrapText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.12 octet string read-write
Dieser Text wird im Trapbody gesendet.
                                           wtWebGraphThermHygroAlarmMailOptions 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.13 octet string read-write
Binr kodierte Optionen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: ungenutzt
                                           wtWebGraphThermHygroAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.14 octet string read-write
IP-Adresse des Gertes, dass eine TCP-Nachricht empfangen soll.
                                           wtWebGraphThermHygroAlarmTcpPort 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15 integer read-write
Portnummer des Gertes, dass eine TCP-Nachricht empfangen soll.
                                           wtWebGraphThermHygroAlarmTcpText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.16 octet string read-write
Dieser Text wird im TCP Trapbody gesendet.
                                           wtWebGraphThermHygroAlarmClearMailSubject 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.17 octet string read-write
Betreffzeile der Alarm Clear Mail.
                                           wtWebGraphThermHygroAlarmClearMailText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.18 octet string read-write
Text der Alarm Clear Mail: liefert die aktuelle Temperatur; n = 1..8. liefert die aktuelle Zeit.
                                           wtWebGraphThermHygroAlarmClearTrapText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.19 octet string read-write
Dieser Text wird im Trapbody gesendet.
                                           wtWebGraphThermHygroAlarmClearTcpText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.20 octet string read-write
Dieser Text wird im TCP Trapbody gesendet.
                                           wtWebGraphThermHygroAlarmDeltaTemp 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.21 octet string read-write
Maximale Temperaturnderung in Grad/min mit maximal 2 Nachkommastellen. Es wird ein Mittelwert einer Periode von 5 Minuten verglichen.
                                           wtWebGraphThermHygroAlarmRHMin 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.22 octet string read-write
Minimum rel. Feuchte in Prozent mit maximal 2 Nachkommastellen.
                                           wtWebGraphThermHygroAlarmRHMax 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.23 octet string read-write
Maximum rel.Feuchte in Prozent mit maximal 2 Nachkommastellen.
                                           wtWebGraphThermHygroAlarmRHHysteresis 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.24 octet string read-write
Hysterese rel. Feuchte in Prozent mit maximal 2 Nachkommastellen.
                                           wtWebGraphThermHygroAlarmAHMin 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.25 octet string read-write
Minimum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen.
                                           wtWebGraphThermHygroAlarmAHMax 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.26 octet string read-write
Maximum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen.
                                           wtWebGraphThermHygroAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.27 octet string read-write
IP-Adresse des Gertes, dass eine Syslog-Nachricht empfangen soll.
                                           wtWebGraphThermHygroAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28 integer read-write
Portnummer des Gertes, dass eine Syslog-Nachricht empfangen soll, default Port ist 514.
                                           wtWebGraphThermHygroAlarmSyslogText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.29 octet string read-write
Jede Syslog-Nachricht beginnt mit einem Priorittsschlssel, einem Zeitstempel und der Host Ip-Nummer gem RFC3164. Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet.
                                           wtWebGraphThermHygroAlarmSyslogClearText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30 octet string read-write
Jede Syslog-Nachricht beginnt mit einem Priorittsschlssel, einem Zeitstempel und der Host Ip-Nummer gem RFC3164. Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet.
                                           wtWebGraphThermHygroAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.31 octet string read-write
Lokaler Datenport: 1..65535 oder AUTO: der nchste ungenutzte Port wird automatisch zugewiesen.
                                           wtWebGraphThermHygroAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.32 octet string read-write
Der File Name kann auch Pfadinformationen enthalten.
                                           wtWebGraphThermHygroAlarmFtpText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.33 octet string read-write
Dieser Text wird in die angegebene Datei geschrieben.
                                           wtWebGraphThermHygroAlarmFtpClearText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.34 octet string read-write
Dieser Text wird in die angegebene Datei geschrieben.
                                           wtWebGraphThermHygroAlarmFtpOptions 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.35 octet string read-write
Binr kodierte Optionen, nur eine Option darf eingeschaltet sein: STORE = Datei ersetzen APPEND = Nachrichten ans Dateiende anhngen Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: ungenutzt
                                           wtWebGraphThermHygroAlarmTimerCron 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.36 octet string read-write
Diser Eintrag enthlt 5 Leerzeichen- oder Tab-getrente Felder zur Definition von zeitgesteuerten Ausgabe von Alarmnachrichten. Jedes der 5 Felder muss mit der aktuelle Zeit bereinstimmen, um das Senden einer Nachricht auszulsen, Wochentag und Monatstag werden getrennt ausgewertet. Feld mglicher Zahlenbereich 1: Minuten 0-59 2. Stunden 0-23, 0 ist Mitternacht 3: Monatstag 1-31 4: Monat 1-12 5: Wochentag 0-6, 0 ist Sonntag Fr jedes Feld kann nun angegeben werden: - eine ganze Zahl aus dem angegebenen Zahlenbereich - ein Teil-Zahlenbereich (wie z.B. 1-5) innerhalb des angegebenen Zahlenbereichs - eine mit Komma getrennte Liste von ganzen Zahlen oder Tei-Zahlenbereichen (wie z.B. 2,4-6,8,10) - ein Stern * (deckt den gesamten erlaubten Bereich ab) - ein / gibt die Schrittweite bei Teil-Zahlenbereichen an (z.B. 0-59/2 jede zweite Minute).
                           wtWebGraphThermHygroPorts 1.3.6.1.4.1.5040.1.2.9.3.2
                               wtWebGraphThermHygroPortTable 1.3.6.1.4.1.5040.1.2.9.3.2.1 no-access
Liste der Einstellungen abhngig von der Sensornummer.
                                   wtWebGraphThermHygroPortEntry 1.3.6.1.4.1.5040.1.2.9.3.2.1.1 no-access
Sensor-Parameter der einzelnen Sensoren.
                                       wtWebGraphThermHygroPortName 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.1 octet string read-write
Name des Sensors.
                                       wtWebGraphThermHygroPortText 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.2 octet string read-write
Beschreibung des Sensors.
                                       wtWebGraphThermHygroPortOffset1 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.3 octet string read-write
Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1.
                                       wtWebGraphThermHygroPortTemperature1 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.4 octet string read-write
Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen.
                                       wtWebGraphThermHygroPortOffset2 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.5 octet string read-write
Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2.
                                       wtWebGraphThermHygroPortTemperature2 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.6 octet string read-write
Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen.
                                       wtWebGraphThermHygroPortComment 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.7 octet string read-write
Offset-Kalibrierung: Angaben zu Datum, Referenzgert, Operator.
                                       wtWebGraphThermHygroPortSensorSelect 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8 octet string read-write
Binr kodierte Optionen fr Sensor 1: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: ungenutzt Binr kodierte Optionen fr Sensor 2: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : W&T Sensor rel. Feuchte (default) Bit 1 : Skalar 0-2.5V Bit 2 : Disconnect Bit 3-7: ungenutzt
                           wtWebGraphThermHygroManufact 1.3.6.1.4.1.5040.1.2.9.3.3
                               wtWebGraphThermHygroMfName 1.3.6.1.4.1.5040.1.2.9.3.3.1 octet string read-write
Hersteller Firmenname
                               wtWebGraphThermHygroMfAddr 1.3.6.1.4.1.5040.1.2.9.3.3.2 octet string read-write
Adresse des Herstellers.
                               wtWebGraphThermHygroMfHotline 1.3.6.1.4.1.5040.1.2.9.3.3.3 octet string read-write
Hotline des Herstellers.
                               wtWebGraphThermHygroMfInternet 1.3.6.1.4.1.5040.1.2.9.3.3.4 octet string read-write
Internet-Adresse des Herstellers.
                               wtWebGraphThermHygroMfDeviceTyp 1.3.6.1.4.1.5040.1.2.9.3.3.5 octet string read-write
Gertebezeichnung (Typ) des Herstellers.
                               wtWebGraphThermHygroMfOrderNo 1.3.6.1.4.1.5040.1.2.9.3.3.6 octet string read-write
Bestellnummer des Gertes des Herstellers.
                       wtWebGraphThermHygroDiag 1.3.6.1.4.1.5040.1.2.9.4
                           wtWebGraphThermHygroDiagErrorCount 1.3.6.1.4.1.5040.1.2.9.4.1 integer read-only
Anzahl der Eintrge im Fehlerspeicher.
                           wtWebGraphThermHygroDiagBinaryError 1.3.6.1.4.1.5040.1.2.9.4.2 octet string read-only
Bitweise kodierte Fehlerursachen.
                           wtWebGraphThermHygroDiagErrorIndex 1.3.6.1.4.1.5040.1.2.9.4.3 integer read-write
Der Wert dieser Variable wird als Index fr die Ausgabe eines Fehlertextes (wtWebGraphThermHygroDiagErrorMessage) verwendet. Die Fehler im Speicher sind von 1 bis wtWebGraphThermHygroDiagErrorCount durchnummeriert. Nach dem Schreiben einens gltigen Wertes in diese Variable kann der dazugehrige Text in wtWebGraphThermHygroDiagErrorMessage ausgelesen werden.
                           wtWebGraphThermHygroDiagErrorMessage 1.3.6.1.4.1.5040.1.2.9.4.4 octet string read-only
Abhngig vom Wert wtWebGraphThermHygroDiagErrorIndex wird ein Fehlertext angezeigt.
                           wtWebGraphThermHygroDiagErrorClear 1.3.6.1.4.1.5040.1.2.9.4.5 integer read-write
Durch Schreiben eine 1 in diese Variable, wird der Fehlerspeicher gelscht.
                         wtWebGraphThermHygroAlert1 1.3.6.1.4.1.5040.1.2.90.31
Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert2 1.3.6.1.4.1.5040.1.2.90.32
Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert3 1.3.6.1.4.1.5040.1.2.90.33
Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert4 1.3.6.1.4.1.5040.1.2.90.34
Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert5 1.3.6.1.4.1.5040.1.2.90.35
Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert6 1.3.6.1.4.1.5040.1.2.90.36
Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert7 1.3.6.1.4.1.5040.1.2.90.37
Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert8 1.3.6.1.4.1.5040.1.2.90.38
Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert9 1.3.6.1.4.1.5040.1.2.90.91
Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gelscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert10 1.3.6.1.4.1.5040.1.2.90.92
Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gelscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert11 1.3.6.1.4.1.5040.1.2.90.93
Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gelscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert12 1.3.6.1.4.1.5040.1.2.90.94
Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gelscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert13 1.3.6.1.4.1.5040.1.2.90.95
Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gelscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert14 1.3.6.1.4.1.5040.1.2.90.96
Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gelscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert15 1.3.6.1.4.1.5040.1.2.90.97
Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gelscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlert16 1.3.6.1.4.1.5040.1.2.90.98
Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gelscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
                         wtWebGraphThermHygroAlertDiag 1.3.6.1.4.1.5040.1.2.90.110
Dieser SNMP-Trap wird generiert, wenn eine Diagnose/Error-Message ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.