WebGraph-AnalogIO-57662-US-MIB: View SNMP OID List / Download MIB

VENDOR: WIESEMANN N THEIS


 Home MIB: WebGraph-AnalogIO-57662-US-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wut 1.3.6.1.4.1.5040
           wtComServer 1.3.6.1.4.1.5040.1
               wtWebio 1.3.6.1.4.1.5040.1.2
                   wtWebGraphAnalog57662 1.3.6.1.4.1.5040.1.2.29
                         wtWebGraphAnalog57662Inventory 1.3.6.1.4.1.5040.1.2.29.1
                             wtWebGraphAnalog57662Sensors 1.3.6.1.4.1.5040.1.2.29.1.1 integer read-only
Number of sensors
                             wtWebGraphAnalog57662SensorTable 1.3.6.1.4.1.5040.1.2.29.1.2 no-access
List of sensors.
                                 wtWebGraphAnalog57662SensorEntry 1.3.6.1.4.1.5040.1.2.29.1.2.1 no-access
List of sensor numbers.
                                     wtWebGraphAnalog57662SensorNo 1.3.6.1.4.1.5040.1.2.29.1.2.1.1 integer read-only
Sensor number.
                             wtWebGraphAnalog57662ValuesTable 1.3.6.1.4.1.5040.1.2.29.1.3 no-access
List of measurement values corresponding to the channel numbers.
                                 wtWebGraphAnalog57662ValuesEntry 1.3.6.1.4.1.5040.1.2.29.1.3.1 no-access
Measurement values of the sensors.
                                     wtWebGraphAnalog57662Values 1.3.6.1.4.1.5040.1.2.29.1.3.1.1 octet string read-write
Measurement value of the sensor, ASCII. This value will be translated according to the ports settings for the read and write operations.
                             wtWebGraphAnalog57662BinaryValuesTable 1.3.6.1.4.1.5040.1.2.29.1.4 no-access
List of binary measurement values corresponding to the channel numbers.
                                 wtWebGraphAnalog57662BinaryValuesEntry 1.3.6.1.4.1.5040.1.2.29.1.4.1 no-access
Binary measurement values of the sensors.
                                     wtWebGraphAnalog57662BinaryValues 1.3.6.1.4.1.5040.1.2.29.1.4.1.1 integer read-write
Binary measurement value of the sensor in 1/1000, signed number, 0x7FFFFFFF indicates an invalid value. This value will be translated according to the ports settings for the read and write operations.
                         wtWebGraphAnalog57662SessCntrl 1.3.6.1.4.1.5040.1.2.29.2
                             wtWebGraphAnalog57662SessCntrlPassword 1.3.6.1.4.1.5040.1.2.29.2.1 octet string read-write
Entering this password opens a session which is ended by writing a 1 to wtWebGraphAnalog57662SessCntrlLogout. When read this variable provides a string of length zero.
                             wtWebGraphAnalog57662SessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.29.2.2 integer read-only
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read. Enumeration: 'wtWebGraphAnalog57662SessCntrl-Session': 1, 'wtWebGraphAnalog57662SessCntrl-NoSession': 0.
                             wtWebGraphAnalog57662SessCntrlLogout 1.3.6.1.4.1.5040.1.2.29.2.3 integer read-write
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
                             wtWebGraphAnalog57662SessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.29.2.4 octet string read-write
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
                             wtWebGraphAnalog57662SessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.29.2.5 octet string read-write
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
                         wtWebGraphAnalog57662Config 1.3.6.1.4.1.5040.1.2.29.3
                             wtWebGraphAnalog57662Device 1.3.6.1.4.1.5040.1.2.29.3.1
                                 wtWebGraphAnalog57662Text 1.3.6.1.4.1.5040.1.2.29.3.1.1
                                     wtWebGraphAnalog57662DeviceName 1.3.6.1.4.1.5040.1.2.29.3.1.1.1 octet string read-write
Name of the Webio, which is user definable.
                                     wtWebGraphAnalog57662DeviceText 1.3.6.1.4.1.5040.1.2.29.3.1.1.2 octet string read-write
Description of the Webio, which is user definable.
                                     wtWebGraphAnalog57662DeviceLocation 1.3.6.1.4.1.5040.1.2.29.3.1.1.3 octet string read-write
Description of the location of the Webio, which is user definable.
                                     wtWebGraphAnalog57662DeviceContact 1.3.6.1.4.1.5040.1.2.29.3.1.1.4 octet string read-write
Contact address of the system operator of the Webio, which is user definable.
                                 wtWebGraphAnalog57662TimeDate 1.3.6.1.4.1.5040.1.2.29.3.1.2
                                     wtWebGraphAnalog57662TimeZone 1.3.6.1.4.1.5040.1.2.29.3.1.2.1
                                         wtWebGraphAnalog57662TzOffsetHrs 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.1 integer read-write
Offset hours for the time zone (winter time) with respect to UTC.
                                         wtWebGraphAnalog57662TzOffsetMin 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.2 integer read-write
Offset minutes for the time zone (winter time) with respect to UTC.
                                         wtWebGraphAnalog57662TzEnable 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.3 octet string read-write
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
                                         wtWebGraphAnalog57662StTzOffsetHrs 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.4 integer read-write
Offset hours of the time zone (summer time) with respect to UTC.
                                         wtWebGraphAnalog57662StTzOffsetMin 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.5 integer read-write
Offset minutes of the time zone (summer time) with respect to UTC.
                                         wtWebGraphAnalog57662StTzEnable 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.6 octet string read-write
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
                                         wtWebGraphAnalog57662StTzStartMonth 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.7 integer read-write
Month in which the change is made from winter time to summer time. Enumeration: 'wtWebGraphAnalog57662StartMonth-February': 2, 'wtWebGraphAnalog57662StartMonth-June': 6, 'wtWebGraphAnalog57662StartMonth-December': 12, 'wtWebGraphAnalog57662StartMonth-March': 3, 'wtWebGraphAnalog57662StartMonth-April': 4, 'wtWebGraphAnalog57662StartMonth-January': 1, 'wtWebGraphAnalog57662StartMonth-November': 11, 'wtWebGraphAnalog57662StartMonth-October': 10, 'wtWebGraphAnalog57662StartMonth-September': 9, 'wtWebGraphAnalog57662StartMonth-July': 7, 'wtWebGraphAnalog57662StartMonth-May': 5, 'wtWebGraphAnalog57662StartMonth-August': 8.
                                         wtWebGraphAnalog57662StTzStartMode 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.8 integer read-write
Mode of the day of the week for which the change is made from winter time to summer time. Enumeration: 'wtWebGraphAnalog57662StartMode-second': 2, 'wtWebGraphAnalog57662StartMode-fourth': 4, 'wtWebGraphAnalog57662StartMode-third': 3, 'wtWebGraphAnalog57662StartMode-first': 1, 'wtWebGraphAnalog57662StartMode-last': 5.
                                         wtWebGraphAnalog57662StTzStartWday 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.9 integer read-write
Day of the week on which the change is made from winter time to summer time Enumeration: 'wtWebGraphAnalog57662StartWday-Sunday': 1, 'wtWebGraphAnalog57662StartWday-Tuesday': 3, 'wtWebGraphAnalog57662StartWday-Thursday': 4, 'wtWebGraphAnalog57662StartWday-Friday': 6, 'wtWebGraphAnalog57662StartWday-Wednesday': 5, 'wtWebGraphAnalog57662StartWday-Monday': 2, 'wtWebGraphAnalog57662StartWday-Saturday': 7.
                                         wtWebGraphAnalog57662StTzStartHrs 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.10 integer read-write
Hour in which the time zone is changed from winter to summer time with respect to UTC.
                                         wtWebGraphAnalog57662StTzStartMin 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.11 integer read-write
Minute in which the time zone is changed from winter to summer time with respect to UTC.
                                         wtWebGraphAnalog57662StTzStopMonth 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.12 integer read-write
Month in which the change is made from summer time to winter time. Enumeration: 'wtWebGraphAnalog57662StopMonth-April': 4, 'wtWebGraphAnalog57662StopMonth-December': 12, 'wtWebGraphAnalog57662StopMonth-November': 11, 'wtWebGraphAnalog57662StopMonth-July': 7, 'wtWebGraphAnalog57662StopMonth-October': 10, 'wtWebGraphAnalog57662StopMonth-March': 3, 'wtWebGraphAnalog57662StopMonth-August': 8, 'wtWebGraphAnalog57662StopMonth-September': 9, 'wtWebGraphAnalog57662StopMonth-January': 1, 'wtWebGraphAnalog57662StopMonth-May': 5, 'wtWebGraphAnalog57662StopMonth-June': 6, 'wtWebGraphAnalog57662StopMonth-February': 2.
                                         wtWebGraphAnalog57662StTzStopMode 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.13 integer read-write
Mode of the week day on which the change is made from summer time to winter time. Enumeration: 'wtWebGraphAnalog57662StopMode-first': 1, 'wtWebGraphAnalog57662StopMode-third': 3, 'wtWebGraphAnalog57662StopMode-second': 2, 'wtWebGraphAnalog57662StopMode-last': 5, 'wtWebGraphAnalog57662StopMode-fourth': 4.
                                         wtWebGraphAnalog57662StTzStopWday 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.14 integer read-write
Day of the week on which the change is made from summer time to winter time. Enumeration: 'wtWebGraphAnalog57662StopWday-Sunday': 1, 'wtWebGraphAnalog57662StopWday-Monday': 2, 'wtWebGraphAnalog57662StopWday-Thursday': 4, 'wtWebGraphAnalog57662StopWday-Friday': 6, 'wtWebGraphAnalog57662StopWday-Wednesday': 5, 'wtWebGraphAnalog57662StopWday-Saturday': 7, 'wtWebGraphAnalog57662StopWday-Tuesday': 3.
                                         wtWebGraphAnalog57662StTzStopHrs 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.15 integer read-write
Hour at which the time zone is changed from summer to winter time with respect to UTC.
                                         wtWebGraphAnalog57662StTzStopMin 1.3.6.1.4.1.5040.1.2.29.3.1.2.1.16 integer read-write
Minute at which the time zone is changed from summer to winter time with respect to UTC.
                                     wtWebGraphAnalog57662TimeServer 1.3.6.1.4.1.5040.1.2.29.3.1.2.2
                                         wtWebGraphAnalog57662TimeServer1 1.3.6.1.4.1.5040.1.2.29.3.1.2.2.1 octet string read-write
IP address or name of the 1st time server in ASCII
                                         wtWebGraphAnalog57662TimeServer2 1.3.6.1.4.1.5040.1.2.29.3.1.2.2.2 octet string read-write
IP address or name of the 2nd time server in ASCII
                                         wtWebGraphAnalog57662TsEnable 1.3.6.1.4.1.5040.1.2.29.3.1.2.2.3 octet string read-write
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
                                         wtWebGraphAnalog57662TsSyncTime 1.3.6.1.4.1.5040.1.2.29.3.1.2.2.4 integer read-write
Daily synchronisation time with the time server (hour: 0-23).
                                     wtWebGraphAnalog57662DeviceClock 1.3.6.1.4.1.5040.1.2.29.3.1.2.3
                                         wtWebGraphAnalog57662ClockHrs 1.3.6.1.4.1.5040.1.2.29.3.1.2.3.1 integer read-write
Clock hours taking into account the time zone settings.
                                         wtWebGraphAnalog57662ClockMin 1.3.6.1.4.1.5040.1.2.29.3.1.2.3.2 integer read-write
Clock minutes taking into account the time zone settings.
                                         wtWebGraphAnalog57662ClockDay 1.3.6.1.4.1.5040.1.2.29.3.1.2.3.3 integer read-write
Date: Day of the month, taking into account the time zone settings.
                                         wtWebGraphAnalog57662ClockMonth 1.3.6.1.4.1.5040.1.2.29.3.1.2.3.4 integer read-write
Date: Month, taking into account the time zone settings. Enumeration: 'wtWebGraphAnalog57662ClockMonth-January': 1, 'wtWebGraphAnalog57662ClockMonth-July': 7, 'wtWebGraphAnalog57662ClockMonth-June': 6, 'wtWebGraphAnalog57662ClockMonth-December': 12, 'wtWebGraphAnalog57662ClockMonth-October': 10, 'wtWebGraphAnalog57662ClockMonth-March': 3, 'wtWebGraphAnalog57662ClockMonth-May': 5, 'wtWebGraphAnalog57662ClockMonth-November': 11, 'wtWebGraphAnalog57662ClockMonth-September': 9, 'wtWebGraphAnalog57662ClockMonth-April': 4, 'wtWebGraphAnalog57662ClockMonth-February': 2, 'wtWebGraphAnalog57662ClockMonth-August': 8.
                                         wtWebGraphAnalog57662ClockYear 1.3.6.1.4.1.5040.1.2.29.3.1.2.3.5 integer read-write
Date: Year, taking into account the time zone settings.
                                 wtWebGraphAnalog57662Basic 1.3.6.1.4.1.5040.1.2.29.3.1.3
                                     wtWebGraphAnalog57662Network 1.3.6.1.4.1.5040.1.2.29.3.1.3.1
                                         wtWebGraphAnalog57662IpAddress 1.3.6.1.4.1.5040.1.2.29.3.1.3.1.1 ipaddress read-write
IP address of the Webio
                                         wtWebGraphAnalog57662SubnetMask 1.3.6.1.4.1.5040.1.2.29.3.1.3.1.2 ipaddress read-write
Subnet mask of the Webio
                                         wtWebGraphAnalog57662Gateway 1.3.6.1.4.1.5040.1.2.29.3.1.3.1.3 ipaddress read-write
Gateway of the Webio
                                         wtWebGraphAnalog57662DnsServer1 1.3.6.1.4.1.5040.1.2.29.3.1.3.1.4 octet string read-write
IP address of the 1st DNS server in ASCII
                                         wtWebGraphAnalog57662DnsServer2 1.3.6.1.4.1.5040.1.2.29.3.1.3.1.5 octet string read-write
IP address of the 2nd DNS server in ASCII
                                         wtWebGraphAnalog57662AddConfig 1.3.6.1.4.1.5040.1.2.29.3.1.3.1.6 octet string read-write
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable
                                     wtWebGraphAnalog57662HTTP 1.3.6.1.4.1.5040.1.2.29.3.1.3.2
                                         wtWebGraphAnalog57662Startup 1.3.6.1.4.1.5040.1.2.29.3.1.3.2.1 octet string read-write
Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time.
                                         wtWebGraphAnalog57662GetHeaderEnable 1.3.6.1.4.1.5040.1.2.29.3.1.3.2.2 octet string read-write
If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
                                         wtWebGraphAnalog57662HttpPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.2.3 integer read-write
Definition of the standard HTML port (Default: 80).
                                     wtWebGraphAnalog57662Mail 1.3.6.1.4.1.5040.1.2.29.3.1.3.3
                                         wtWebGraphAnalog57662MailAdName 1.3.6.1.4.1.5040.1.2.29.3.1.3.3.1 octet string read-write
Device name for mail administration.
                                         wtWebGraphAnalog57662MailReply 1.3.6.1.4.1.5040.1.2.29.3.1.3.3.2 octet string read-write
Reply address for the mail server.
                                         wtWebGraphAnalog57662MailServer 1.3.6.1.4.1.5040.1.2.29.3.1.3.3.3 octet string read-write
Name or IP address of the mail server.
                                         wtWebioAn1MailEnable 1.3.6.1.4.1.5040.1.2.29.3.1.3.3.4 octet string read-write
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
                                         wtWebGraphAnalog57662MailAuthentication 1.3.6.1.4.1.5040.1.2.29.3.1.3.3.5 octet string read-write
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
                                         wtWebGraphAnalog57662MailAuthUser 1.3.6.1.4.1.5040.1.2.29.3.1.3.3.6 octet string read-write
Name of the user to be authenticated.
                                         wtWebGraphAnalog57662MailAuthPassword 1.3.6.1.4.1.5040.1.2.29.3.1.3.3.7 octet string read-write
Authentication password.
                                         wtWebGraphAnalog57662MailPop3Server 1.3.6.1.4.1.5040.1.2.29.3.1.3.3.8 octet string read-write
Name or Ip-address of the POP3 Servers.
                                     wtWebGraphAnalog57662SNMP 1.3.6.1.4.1.5040.1.2.29.3.1.3.4
                                         wtWebGraphAnalog57662SnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.29.3.1.3.4.1 octet string read-write
Community string read only
                                         wtWebGraphAnalog57662SnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.29.3.1.3.4.2 octet string read-write
Community string read / write
                                         wtWebGraphAnalog57662SystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.29.3.1.3.4.3 octet string read-write
Name or IP address of the TCP server which accepts the system trap.
                                         wtWebGraphAnalog57662SystemTrapEnable 1.3.6.1.4.1.5040.1.2.29.3.1.3.4.4 octet string read-write
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused
                                         wtWebGraphAnalog57662SnmpEnable 1.3.6.1.4.1.5040.1.2.29.3.1.3.4.5 octet string read-write
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
                                         wtWebGraphAnalog57662SnmpCommunityStringTrap 1.3.6.1.4.1.5040.1.2.29.3.1.3.4.6 octet string read-write
Community string send within traps.
                                     wtWebGraphAnalog57662UDP 1.3.6.1.4.1.5040.1.2.29.3.1.3.5
                                         wtWebGraphAnalog57662UdpPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.5.1 integer read-write
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
                                         wtWebGraphAnalog57662UdpEnable 1.3.6.1.4.1.5040.1.2.29.3.1.3.5.2 octet string read-write
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
                                     wtWebGraphAnalog57662Syslog 1.3.6.1.4.1.5040.1.2.29.3.1.3.6
                                         wtWebGraphAnalog57662SyslogServerIP 1.3.6.1.4.1.5040.1.2.29.3.1.3.6.1 octet string read-write
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
                                         wtWebGraphAnalog57662SyslogServerPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.6.2 integer read-write
Portnumber of the Syslog servers, default 514.
                                         wtWebGraphAnalog57662SyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.29.3.1.3.6.3 octet string read-write
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
                                         wtWebGraphAnalog57662SyslogEnable 1.3.6.1.4.1.5040.1.2.29.3.1.3.6.4 octet string read-write
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
                                     wtWebGraphAnalog57662FTP 1.3.6.1.4.1.5040.1.2.29.3.1.3.7
                                         wtWebGraphAnalog57662FTPServerIP 1.3.6.1.4.1.5040.1.2.29.3.1.3.7.1 octet string read-write
Name or IP address of the FTP server, which accepts the FTP messages.
                                         wtWebGraphAnalog57662FTPServerControlPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.7.2 integer read-write
Portnumber of the control port of the FTP server, default 21.
                                         wtWebGraphAnalog57662FTPUserName 1.3.6.1.4.1.5040.1.2.29.3.1.3.7.3 octet string read-write
FTP Loggin: user name.
                                         wtWebGraphAnalog57662FTPPassword 1.3.6.1.4.1.5040.1.2.29.3.1.3.7.4 octet string read-write
FTP Loggin: user password.
                                         wtWebGraphAnalog57662FTPAccount 1.3.6.1.4.1.5040.1.2.29.3.1.3.7.5 octet string read-write
FTP Loggin: name of account.
                                         wtWebGraphAnalog57662FTPOption 1.3.6.1.4.1.5040.1.2.29.3.1.3.7.6 octet string read-write
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
                                         wtWebGraphAnalog57662FTPEnable 1.3.6.1.4.1.5040.1.2.29.3.1.3.7.7 octet string read-write
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
                                     wtWebGraphAnalog57662Language 1.3.6.1.4.1.5040.1.2.29.3.1.3.8
                                         wtWebGraphAnalog57662LanguageSelect 1.3.6.1.4.1.5040.1.2.29.3.1.3.8.1 octet string read-write
Language selection: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : English Bit 0 : German
                                     wtWebGraphAnalog57662Binary 1.3.6.1.4.1.5040.1.2.29.3.1.3.9
                                         wtWebGraphAnalog57662BinaryModeCount 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.1 integer read-only
Number of independent binary channels.
                                         wtWebGraphAnalog57662BinaryIfTable 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.2 no-access
Table of indices.
                                             wtWebGraphAnalog57662BinaryIfEntry 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.2.1 no-access
Indices of the binary channels.
                                                 wtWebGraphAnalog57662BinaryModeNo 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.2.1.1 integer read-only
Number of the binary channel.
                                         wtWebGraphAnalog57662BinaryTable 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3 no-access
Table of properties of the binary mode.
                                             wtWebGraphAnalog57662BinaryEntry 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1 no-access
Binary properties.
                                                 wtWebGraphAnalog57662BinaryOperationMode 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.1 octet string read-write
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
                                                 wtWebGraphAnalog57662BinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.2 integer read-write
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
                                                 wtWebGraphAnalog57662BinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.3 octet string read-write
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input states. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Analog inputs 0-1
                                                 wtWebGraphAnalog57662BinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.4 octet string read-write
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
                                                 wtWebGraphAnalog57662BinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.5 integer read-write
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
                                                 wtWebGraphAnalog57662BinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.6 integer read-write
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
                                                 wtWebGraphAnalog57662BinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.7 octet string read-write
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
                                                 wtWebGraphAnalog57662BinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.8 octet string read-write
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
                                                 wtWebGraphAnalog57662BinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.9 integer read-write
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
                                                 wtWebGraphAnalog57662BinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.10 octet string read-write
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input states. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Analog inputs 0-1
                                                 wtWebGraphAnalog57662BinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.11 integer read-write
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
                                                 wtWebGraphAnalog57662BinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.12 octet string read-write
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
                                                 wtWebGraphAnalog57662BinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.13 integer read-write
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
                                                 wtWebGraphAnalog57662BinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.14 integer read-write
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
                                                 wtWebGraphAnalog57662BinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.15 octet string read-write
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
                                                 wtWebGraphAnalog57662BinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.16 octet string read-write
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input states. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Analog inputs 0-1
                                                 wtWebGraphAnalog57662BinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.17 integer read-write
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
                                                 wtWebGraphAnalog57662BinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.18 octet string read-write
Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
                                                 wtWebGraphAnalog57662BinaryConnectedPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.19 integer read-only
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
                                                 wtWebGraphAnalog57662BinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.20 ipaddress read-only
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
                                                 wtWebGraphAnalog57662BinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.21 integer read-write
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
                                                 wtWebGraphAnalog57662BinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.22 integer read-write
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
                                                 wtWebGraphAnalog57662BinaryTcpServerHysteresis1 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.23 octet string read-write
A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57662BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be transmitted.
                                                 wtWebGraphAnalog57662BinaryTcpServerHysteresis2 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.24 octet string read-write
A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57662BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be transmitted.
                                                 wtWebGraphAnalog57662BinaryTcpClientHysteresis1 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.25 octet string read-write
A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57662BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be transmitted.
                                                 wtWebGraphAnalog57662BinaryTcpClientHysteresis2 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.26 octet string read-write
A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57662BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be transmitted.
                                                 wtWebGraphAnalog57662BinaryUdpPeerHysteresis1 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.27 octet string read-write
A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57662BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be transmitted.
                                                 wtWebGraphAnalog57662BinaryUdpPeerHysteresis2 1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.28 octet string read-write
A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57662BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be transmitted.
                                 wtWebGraphAnalog57662Datalogger 1.3.6.1.4.1.5040.1.2.29.3.1.4
                                     wtWebGraphAnalog57662LoggerTimebase 1.3.6.1.4.1.5040.1.2.29.3.1.4.1 integer read-write
Time base of the data logger Enumeration: 'wtWebGraphAnalog57662Datalogger-60Min': 6, 'wtWebGraphAnalog57662Datalogger-5Min': 4, 'wtWebGraphAnalog57662Datalogger-30Sec': 2, 'wtWebGraphAnalog57662Datalogger-1Min': 3, 'wtWebGraphAnalog57662Datalogger-15Sec': 1, 'wtWebGraphAnalog57662Datalogger-15Min': 5.
                                     wtWebGraphAnalog57662LoggerSensorSel 1.3.6.1.4.1.5040.1.2.29.3.1.4.2 octet string read-write
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
                                     wtWebGraphAnalog57662DisplaySensorSel 1.3.6.1.4.1.5040.1.2.29.3.1.4.3 octet string read-write
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
                                     wtWebGraphAnalog57662SensorColorTable 1.3.6.1.4.1.5040.1.2.29.3.1.4.4 no-access
List of sensor colors for the praphical presentation.
                                         wtWebGraphAnalog57662SensorColorEntry 1.3.6.1.4.1.5040.1.2.29.3.1.4.4.1 no-access
Index numbers of the sensors.
                                             wtWebGraphAnalog57662SensorColor 1.3.6.1.4.1.5040.1.2.29.3.1.4.4.1.1 octet string read-write
Color of the sensors at the praphical presention.
                                     wtWebGraphAnalog57662AutoScaleEnable 1.3.6.1.4.1.5040.1.2.29.3.1.4.5 octet string read-write
If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable
                                     wtWebGraphAnalog57662VerticalUpperLimit 1.3.6.1.4.1.5040.1.2.29.3.1.4.6 octet string read-write
This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
                                     wtWebGraphAnalog57662VerticalLowerLimit 1.3.6.1.4.1.5040.1.2.29.3.1.4.7 octet string read-write
This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
                                     wtWebGraphAnalog57662HorizontalZoom 1.3.6.1.4.1.5040.1.2.29.3.1.4.8 integer read-write
Defines the default zoom stage, if no auto scaling is selected. Enumeration: 'wtWebGraphAnalog57662Zoom-30hrs': 4, 'wtWebGraphAnalog57662Zoom-25days': 6, 'wtWebGraphAnalog57662Zoom-75min': 2, 'wtWebGraphAnalog57662Zoom-5hrs': 3, 'wtWebGraphAnalog57662Zoom-5days': 5, 'wtWebGraphAnalog57662Zoom-25min': 1.
                                 wtWebGraphAnalog57662Alarm 1.3.6.1.4.1.5040.1.2.29.3.1.5
                                     wtWebGraphAnalog57662AlarmCount 1.3.6.1.4.1.5040.1.2.29.3.1.5.1 integer read-only
Number of independent alarms.
                                     wtWebGraphAnalog57662AlarmIfTable 1.3.6.1.4.1.5040.1.2.29.3.1.5.2 no-access
List of alarm indices.
                                         wtWebGraphAnalog57662AlarmIfEntry 1.3.6.1.4.1.5040.1.2.29.3.1.5.2.1 no-access
Numbers of the alarms.
                                             wtWebGraphAnalog57662AlarmNo 1.3.6.1.4.1.5040.1.2.29.3.1.5.2.1.1 integer read-only
Alarm number.
                                     wtWebGraphAnalog57662AlarmTable 1.3.6.1.4.1.5040.1.2.29.3.1.5.3 no-access
List of settings depending on the alarm number.
                                         wtWebGraphAnalog57662AlarmEntry 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1 no-access
Alarm parameters of the individual alarms.
                                             wtWebGraphAnalog57662AlarmTrigger 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.1 octet string read-write
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
                                             wtWebGraphAnalog57662AlarmMin1 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.2 octet string read-write
Minimum sensor 1 with maximum 3 decimal places.
                                             wtWebGraphAnalog57662AlarmMax1 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.3 octet string read-write
Maximum sensor 1 with maximum 3 decimal places.
                                             wtWebGraphAnalog57662AlarmHysteresis1 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.4 octet string read-write
Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) with maximum 3 decimal places.
                                             wtWebGraphAnalog57662AlarmDelay 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.5 octet string read-write
Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes).
                                             wtWebGraphAnalog57662AlarmInterval 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.6 octet string read-write
Send interval for alarm messages.
                                             wtWebGraphAnalog57662AlarmEnable 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.7 octet string read-write
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable
                                             wtWebGraphAnalog57662AlarmEMailAddr 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.8 octet string read-write
E-Mail address for sending the alarm mail to.
                                             wtWebGraphAnalog57662AlarmMailSubject 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.9 octet string read-write
Subject line for alarm mail.
                                             wtWebGraphAnalog57662AlarmMailText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.10 octet string read-write
Alarm mail text: provides the current temperature; n = 1..2. provides the current time.
                                             wtWebGraphAnalog57662AlarmManagerIP 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.11 octet string read-write
Name or IP address of the SNMP Manager which accepts the trap.
                                             wtWebGraphAnalog57662AlarmTrapText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.12 octet string read-write
This text is sent in the trap body.
                                             wtWebGraphAnalog57662AlarmMailOptions 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.13 octet string read-write
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused
                                             wtWebGraphAnalog57662AlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.14 octet string read-write
Name or IP address of the TCP server which accepts the trap.
                                             wtWebGraphAnalog57662AlarmTcpPort 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.15 integer read-write
Port number of the TCP server which accepts the trap.
                                             wtWebGraphAnalog57662AlarmTcpText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.16 octet string read-write
This text is sent in the TCP trap body.
                                             wtWebGraphAnalog57662AlarmClearMailSubject 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.17 octet string read-write
Subject line for alarm clear mail.
                                             wtWebGraphAnalog57662AlarmClearMailText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.18 octet string read-write
Alarm clear mail text: provides the current temperature; n = 1..2. provides the current time.
                                             wtWebGraphAnalog57662AlarmClearTrapText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.19 octet string read-write
This text is sent in the trap body.
                                             wtWebGraphAnalog57662AlarmClearTcpText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.20 octet string read-write
This text is sent in the TCP trap body.
                                             wtWebGraphAnalog57662AlarmMin2 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.21 octet string read-write
Minimum sensor 2 with maximum 3 decimal places.
                                             wtWebGraphAnalog57662AlarmMax2 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.22 octet string read-write
Maximum sensor 2 with maximum 2 decimal places.
                                             wtWebGraphAnalog57662AlarmHysteresis2 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.23 octet string read-write
Hysterese rel. sensor 2 with maximum 3 decimal places.
                                             wtWebGraphAnalog57662AlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.24 octet string read-write
IP address of the syslog server to which the Webio device should send syslog messages.
                                             wtWebGraphAnalog57662AlarmSyslogPort 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.25 integer read-write
Port number of the syslog server to which the Webio device should send syslog messages.
                                             wtWebGraphAnalog57662AlarmSyslogText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.26 octet string read-write
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
                                             wtWebGraphAnalog57662AlarmSyslogClearText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.27 octet string read-write
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of a alarm clear message.
                                             wtWebGraphAnalog57662AlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.28 octet string read-write
Local data port: 1..65535 or AUTO: the next free port will be assigned.
                                             wtWebGraphAnalog57662AlarmFtpFileName 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.29 octet string read-write
Name of the file including path informations.
                                             wtWebGraphAnalog57662AlarmFtpText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.30 octet string read-write
Message text to store on the FTP server.
                                             wtWebGraphAnalog57662AlarmFtpClearText 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.31 octet string read-write
Alarm clear message to store on the FTP server.
                                             wtWebGraphAnalog57662AlarmFtpOption 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.32 octet string read-write
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
                                             wtWebGraphAnalog57662AlarmTimerCron 1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.33 octet string read-write
This entry defines a time window for alarm 1-8 and a activation time for the report. A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a single start time stamp. Each time stamp contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger an action, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas (i.e.: 2,14,22) - a partition within the allowed range (i.e.: 1-5) - step size within a partition of the allowed range (i.e.: 0-59/2 every second minute).
                                 wtWebGraphAnalog57662Graphics 1.3.6.1.4.1.5040.1.2.29.3.1.6
                                     wtWebGraphAnalog57662GraphicsBase 1.3.6.1.4.1.5040.1.2.29.3.1.6.1
                                         wtWebGraphAnalog57662GraphicsBaseEnable 1.3.6.1.4.1.5040.1.2.29.3.1.6.1.1 octet string read-write
Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused
                                         wtWebGraphAnalog57662GraphicsBaseWidth 1.3.6.1.4.1.5040.1.2.29.3.1.6.1.2 integer read-write
Defines the width of the graphic in pixels.
                                         wtWebGraphAnalog57662GraphicsBaseHeight 1.3.6.1.4.1.5040.1.2.29.3.1.6.1.3 integer read-write
Defines the height of the graphic in pixels.
                                         wtWebGraphAnalog57662GraphicsBaseFrameColor 1.3.6.1.4.1.5040.1.2.29.3.1.6.1.4 octet string read-write
Frame color definition in RGB.
                                         wtWebGraphAnalog57662GraphicsBaseBackgroundColor 1.3.6.1.4.1.5040.1.2.29.3.1.6.1.5 octet string read-write
Background color definition in RGB.
                                         wtWebGraphAnalog57662GraphicsBasePollingrate 1.3.6.1.4.1.5040.1.2.29.3.1.6.1.6 integer read-write
Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic.
                                     wtWebGraphAnalog57662GraphicsSelect 1.3.6.1.4.1.5040.1.2.29.3.1.6.2
                                         wtWebGraphAnalog57662GraphicsSelectDisplaySensorSel 1.3.6.1.4.1.5040.1.2.29.3.1.6.2.1 octet string read-write
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
                                         wtWebGraphAnalog57662GraphicsSelectDisplayShowExtrem 1.3.6.1.4.1.5040.1.2.29.3.1.6.2.2 octet string read-write
Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
                                         wtWebGraphAnalog57662SensorColor2Table 1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3 no-access
List of sensor colors for the praphical presentation.
                                             wtWebGraphAnalog57662SensorColor2Entry 1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3.1 no-access
Numbers of the sensors.
                                                 wtWebGraphAnalog57662GraphicsSensorColor 1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3.1.1 octet string read-write
Color of the sensors at the praphical presention.
                                                 wtWebGraphAnalog57662GraphicsSelectScale 1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3.1.2 octet string read-write
Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2-7: unused
                                     wtWebGraphAnalog57662GraphicsScale 1.3.6.1.4.1.5040.1.2.29.3.1.6.3
                                         wtWebGraphAnalog57662GraphicsScaleAutoScaleEnable 1.3.6.1.4.1.5040.1.2.29.3.1.6.3.1 octet string read-write
Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2-7: unused
                                         wtWebGraphAnalog57662GraphicsScaleAutoFitEnable 1.3.6.1.4.1.5040.1.2.29.3.1.6.3.2 octet string read-write
Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2-7: unused
                                         wtWebGraphAnalog57662GraphicsScale1Min 1.3.6.1.4.1.5040.1.2.29.3.1.6.3.3 integer read-only
Scale 1: Minimum.
                                         wtWebGraphAnalog57662GraphicsScale2Min 1.3.6.1.4.1.5040.1.2.29.3.1.6.3.4 integer read-only
Scale 2: Minimum.
                                         wtWebGraphAnalog57662GraphicsScale1Max 1.3.6.1.4.1.5040.1.2.29.3.1.6.3.7 integer read-only
Scale 1: Maximum.
                                         wtWebGraphAnalog57662GraphicsScale2Max 1.3.6.1.4.1.5040.1.2.29.3.1.6.3.8 integer read-only
Scale 2: Maximum.
                                         wtWebGraphAnalog57662GraphicsScale1Unit 1.3.6.1.4.1.5040.1.2.29.3.1.6.3.11 octet string read-only
Scale 1: Unit.
                                         wtWebGraphAnalog57662GraphicsScale2Unit 1.3.6.1.4.1.5040.1.2.29.3.1.6.3.12 octet string read-only
Scale 2: Unit.
                                 wtWebGraphAnalog57662Report 1.3.6.1.4.1.5040.1.2.29.3.1.7
                                     wtWebGraphAnalog57662ReportCount 1.3.6.1.4.1.5040.1.2.29.3.1.7.1 integer read-only
Number of independent Reports.
                                     wtWebGraphAnalog57662ReportIfTable 1.3.6.1.4.1.5040.1.2.29.3.1.7.2 no-access
List of Report indices.
                                         wtWebGraphAnalog57662ReportIfEntry 1.3.6.1.4.1.5040.1.2.29.3.1.7.2.1 no-access
Numbers of the Reports.
                                             wtWebGraphAnalog57662ReportNo 1.3.6.1.4.1.5040.1.2.29.3.1.7.2.1.1 integer read-only
Report number.
                                     wtWebGraphAnalog57662ReportTable 1.3.6.1.4.1.5040.1.2.29.3.1.7.3 no-access
List of settings depending on the Report number.
                                         wtWebGraphAnalog57662ReportEntry 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1 no-access
Report parameters of the individual Reports.
                                             wtWebGraphAnalog57662ReportEnable 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.1 octet string read-write
Binr kodierte Triggerbedingungen: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Report enable Bit 1-7: unused
                                             wtWebGraphAnalog57662ReportTimerCron 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.2 octet string read-write
This entry defines a time window for alarm 1-8 and a activation time for the report. A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a single start time stamp. Each time stamp contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger an action, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas (i.e.: 2,14,22) - a partition within the allowed range (i.e.: 1-5) - step size within a partition of the allowed range (i.e.: 0-59/2 every second minute).
                                             wtWebGraphAnalog57662ReportMethodeEnable 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.3 octet string read-write
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog enable Bit 4: FTP Client enable
                                             wtWebGraphAnalog57662ReportEMailAddr 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.8 octet string read-write
E-Mail address for sending the alarm mail to.
                                             wtWebGraphAnalog57662ReportMailSubject 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.9 octet string read-write
Subject line for alarm mail.
                                             wtWebGraphAnalog57662ReportMailText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.10 octet string read-write
Report mail text: provides the current temperature; n = 1..2. provides the current time.
                                             wtWebGraphAnalog57662ReportManagerIP 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.11 octet string read-write
Name or IP address of the SNMP Manager which accepts the trap.
                                             wtWebGraphAnalog57662ReportTrapText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.12 octet string read-write
This text is sent in the trap body.
                                             wtWebGraphAnalog57662ReportMailOptions 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.13 octet string read-write
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused
                                             wtWebGraphAnalog57662ReportTcpIpAddr 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.14 octet string read-write
Name or IP address of the TCP server which accepts the trap.
                                             wtWebGraphAnalog57662ReportTcpPort 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.15 integer read-write
Port number of the TCP server which accepts the trap.
                                             wtWebGraphAnalog57662ReportTcpText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.16 octet string read-write
This text is sent in the TCP trap body.
                                             wtWebGraphAnalog57662ReportClearMailSubject 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.17 octet string read-write
Subject line for alarm clear mail.
                                             wtWebGraphAnalog57662ReportClearMailText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.18 octet string read-write
Report clear mail text: provides the current temperature; n = 1..2. provides the current time.
                                             wtWebGraphAnalog57662ReportClearTrapText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.19 octet string read-write
This text is sent in the trap body.
                                             wtWebGraphAnalog57662ReportClearTcpText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.20 octet string read-write
This text is sent in the TCP trap body.
                                             wtWebGraphAnalog57662ReportSyslogIpAddr 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.24 octet string read-write
IP address of the syslog server to which the Webio device should send syslog messages.
                                             wtWebGraphAnalog57662ReportSyslogPort 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.25 integer read-write
Port number of the syslog server to which the Webio device should send syslog messages.
                                             wtWebGraphAnalog57662ReportSyslogText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.26 octet string read-write
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
                                             wtWebGraphAnalog57662ReportSyslogClearText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.27 octet string read-write
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of a alarm clear message.
                                             wtWebGraphAnalog57662ReportFtpDataPort 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.28 octet string read-write
Local data port: 1..65535 or AUTO: the next free port will be assigned.
                                             wtWebGraphAnalog57662ReportFtpFileName 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.29 octet string read-write
Name of the file including path informations.
                                             wtWebGraphAnalog57662ReportFtpText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.30 octet string read-write
Message text to store on the FTP server.
                                             wtWebGraphAnalog57662ReportFtpClearText 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.31 octet string read-write
Report clear message to store on the FTP server.
                                             wtWebGraphAnalog57662ReportFtpOption 1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.32 octet string read-write
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
                             wtWebGraphAnalog57662Ports 1.3.6.1.4.1.5040.1.2.29.3.2
                                 wtWebGraphAnalog57662PortTable 1.3.6.1.4.1.5040.1.2.29.3.2.1 no-access
List of settings depending on the sensor number.
                                     wtWebGraphAnalog57662PortEntry 1.3.6.1.4.1.5040.1.2.29.3.2.1.1 no-access
Sensor parameters for the individual sensors.
                                         wtWebGraphAnalog57662PortName 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.1 octet string read-write
Name of the sensor.
                                         wtWebGraphAnalog57662PortText 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.2 octet string read-write
Description of the sensor.
                                         wtWebGraphAnalog57662PortOffset1 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.3 octet string read-write
Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1.
                                         wtWebGraphAnalog57662SetPoint1 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.4 octet string read-write
Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places.
                                         wtWebGraphAnalog57662PortOffset2 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.5 octet string read-write
Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2.
                                         wtWebGraphAnalog57662SetPoint2 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.6 octet string read-write
Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places.
                                         wtWebGraphAnalog57662PortComment 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.7 octet string read-write
Offset calibration: informations of date, name of operator, reference devices.
                                         wtWebGraphAnalog57662PortSensorSelect 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.8 octet string read-write
Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7: unused
                                         wtWebGraphAnalog57662PortUnit 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.9 octet string read-write
User scale: displayed unit.
                                         wtWebGraphAnalog57662PortScale0 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.10 octet string read-write
User scale: displayed value in 1/1000 at 0% full scale range. Range: -999999.999 to 999999.999
                                         wtWebGraphAnalog57662PortScale100 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.11 octet string read-write
User scale: displayed value in 1/1000 at 100% full scale range. Range: -999999.999 to 999999.999
                                         wtWebGraphAnalog57662PortOutputMode 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.12 octet string read-write
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. If an output mode is selected, Bit 2 in wtWebGraphAnalog57662PortInputMode will be set automatically. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Output OFF Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
                                         wtWebGraphAnalog57662PortInputMode 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.13 octet string read-write
This binary coded input mode defines the individual operation mode for any input. More than one mode must not be selected. If an input mode is selected, Bit 5 in wtWebGraphAnalog57662PortOutputMode will be set automatically. The OCTETS are interpreted bit-by-bit,Bit 0 corresponds to the LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4: Bit 3-7: unused Bit 2 : I-Output Bit 1 : I-Input, active Bit 0 : I-Input, passive
                                         wtWebGraphAnalog57662PortCompensationValue 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.14 octet string read-write
This entry is used to optimize the step response with capcitive loads.
                                         wtWebGraphAnalog57662PortCompensationMode 1.3.6.1.4.1.5040.1.2.29.3.2.1.1.15 octet string read-write
This binary coded compensation mode defines the individual operation mode for any output. If Auto adaptive is selected, the optimal value of wtWebGraphAnalog57662PortCompensationValue will be determinate continuously. Set Bit 1 to start with the last saved value of wtWebGraphAnalog57662PortCompensationValue in this Mode. If Bit 0 is cleared and Auto Mode is off wtWebGraphAnalog57662PortCompensationValue will allways be used, regardless of the state of Bit 1. The OCTETS are interpreted bit-by-bit,Bit 0 corresponds to the LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4: Bit 2-7: unused Bit 1 : Use saved value at power on Bit 0 : Auto adaptive enable
                             wtWebGraphAnalog57662Manufact 1.3.6.1.4.1.5040.1.2.29.3.3
                                 wtWebGraphAnalog57662MfName 1.3.6.1.4.1.5040.1.2.29.3.3.1 octet string read-write
Manufacturer company name
                                 wtWebGraphAnalog57662MfAddr 1.3.6.1.4.1.5040.1.2.29.3.3.2 octet string read-write
Manufacturer address.
                                 wtWebGraphAnalog57662MfHotline 1.3.6.1.4.1.5040.1.2.29.3.3.3 octet string read-write
Manufacturer hotline.
                                 wtWebGraphAnalog57662MfInternet 1.3.6.1.4.1.5040.1.2.29.3.3.4 octet string read-write
Manufacturer Internet address.
                                 wtWebGraphAnalog57662MfDeviceTyp 1.3.6.1.4.1.5040.1.2.29.3.3.5 octet string read-write
Manufacturer device name (model number).
                                 wtWebGraphAnalog57662MfOrderNo 1.3.6.1.4.1.5040.1.2.29.3.3.6 octet string read-write
Manufacturer part number.
                         wtWebGraphAnalog57662Diag 1.3.6.1.4.1.5040.1.2.29.4
                             wtWebGraphAnalog57662DiagErrorCount 1.3.6.1.4.1.5040.1.2.29.4.1 integer read-only
Number of entries in the error memory.
                             wtWebGraphAnalog57662DiagBinaryError 1.3.6.1.4.1.5040.1.2.29.4.2 octet string read-only
Error causes coded bit-by-bit.
                             wtWebGraphAnalog57662DiagErrorIndex 1.3.6.1.4.1.5040.1.2.29.4.3 integer read-write
The value of this variable is used as an index to read an error massege from wtWebGraphAnalog57662DiagErrorMessage. Errors are numbered from 1 to wtWebGraphAnalog57662DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphAnalog57662DiagErrorMessage.
                             wtWebGraphAnalog57662DiagErrorMessage 1.3.6.1.4.1.5040.1.2.29.4.4 octet string read-only
Using wtWebGraphAnalog57662DiagErrorIndex as an index, the appropriate message is available.
                             wtWebGraphAnalog57662DiagErrorClear 1.3.6.1.4.1.5040.1.2.29.4.5 integer read-write
Writing 1 into this variable clears all diagnosis messages.
                           wtWebGraphAnalog57662Alert1 1.3.6.1.4.1.5040.1.2.290.31
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert2 1.3.6.1.4.1.5040.1.2.290.32
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert3 1.3.6.1.4.1.5040.1.2.290.33
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert4 1.3.6.1.4.1.5040.1.2.290.34
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert5 1.3.6.1.4.1.5040.1.2.290.35
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert6 1.3.6.1.4.1.5040.1.2.290.36
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert7 1.3.6.1.4.1.5040.1.2.290.37
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert8 1.3.6.1.4.1.5040.1.2.290.38
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662AlertReport 1.3.6.1.4.1.5040.1.2.290.39
This SNMP trap is generated when the report was triggered, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert9 1.3.6.1.4.1.5040.1.2.290.91
This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert10 1.3.6.1.4.1.5040.1.2.290.92
This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert11 1.3.6.1.4.1.5040.1.2.290.93
This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert12 1.3.6.1.4.1.5040.1.2.290.94
This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert13 1.3.6.1.4.1.5040.1.2.290.95
This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert14 1.3.6.1.4.1.5040.1.2.290.96
This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert15 1.3.6.1.4.1.5040.1.2.290.97
This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662Alert16 1.3.6.1.4.1.5040.1.2.290.98
This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled.
                           wtWebGraphAnalog57662AlertDiag 1.3.6.1.4.1.5040.1.2.290.110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.